Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
Alzheimers Dement (Amst) ; 16(3): e12623, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39130802

RESUMO

INTRODUCTION: Whether circulating levels of sphingolipids are prospectively associated with cognitive decline and dementia risk is uncertain. METHODS: We measured 14 sphingolipid species in plasma samples from 4488 participants (mean age 76.2 years; 40% male; and 25% apolipoprotein E (APOE) ε4 allele carriers). Cognitive decline was assessed annually across 6 years using modified Mini-Mental State Examination (3MSE) and Digital Symbol Substitution Test (DSST). Additionally, a subset of 3050 participants were followed for clinically adjudicated dementia. RESULTS: Higher plasma levels of sphingomyelin-d18:1/16:0 (SM-16) were associated with a faster cognitive decline measured with 3MSE, in contrast, higher levels of sphingomyelin-d18:1/22:0 (SM-22) were associated with slower decline in cognition measured with DSST. In Cox regression, higher levels of SM-16 (hazard ration [HR] = 1.24 [95% confidence interval [CI]: 1.08-1.44]) and ceramide-d18:1/16:0 (Cer-16) (HR = 1.26 [95% CI: 1.10-1.45]) were associated with higher risk of incident dementia. DISCUSSION: Several sphingolipid species appear to be involved in cognitive decline and dementia risk. Highlights: Plasma levels of sphingolipids were associated with cognitive decline and dementia risk.Ceramides and sphingomyelins with palmitic acid were associated with faster annual cognitive decline and increased risk of dementia.The direction of association depended on the covalently bound saturated fatty acid chain length in analysis of cognitive decline.

2.
Endocrine ; 2024 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-39030378

RESUMO

BACKGROUND: To address the challenges posed by inconsistent detection of analog insulin in commercially available insulin immunoassays, resulting in potential discrepancies in clinical findings and misdiagnosis during the investigation of factitious hypoglycemia., we aimed to evaluate the ability of the Siemens Atellica automated immunoassay to detect insulin analogs compared with LC-MS/MS. METHODS: Five insulin analogs were analyzed at 10 ng/mL spiked into serum samples, with recombinant human insulin as positive controls. Insulin and C-peptide assays were performed using Siemens Atellica and LC-MS/MS. Recovery rates were calculated. RESULTS: Siemens Atellica immunoassay demonstrated robust cross-reactivity (92-121%) of insulin analogs. In contrast, glargine was detected by LC-MS/MS but other analogs were not observed (<10% recovery). CONCLUSION: Our results indicate that the insulin assay conducted on the Siemens Atellica platform could be used to diagnose factitious hypoglycemia by detecting the specific insulin analogs involved. The findings from our studies indicate the suitability of this method for clinical laboratory use in cases where factitious hypoglycemia is under consideration as a potential diagnosis. Clinicians should take these results into account when interpreting insulin measurements, particularly in instances where insulin analog overdose is suspected.

3.
bioRxiv ; 2024 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-39071267

RESUMO

Proteins which bind intrinsically disordered proteins (IDPs) and intrinsically disordered regions (IDRs) with high affinity and specificity could have considerable utility for therapeutic and diagnostic applications. However, a general methodology for targeting IDPs/IDRs has yet to be developed. Here, we show that starting only from the target sequence of the input, and freely sampling both target and binding protein conformation, RFdiffusion can generate binders to IDPs and IDRs in a wide range of conformations. We use this approach to generate binders to the IDPs Amylin, C-peptide and VP48 in a range of conformations with Kds in the 3 -100nM range. The Amylin binder inhibits amyloid fibril formation and dissociates existing fibers, and enables enrichment of amylin for mass spectrometry-based detection. For the IDRs G3bp1, common gamma chain (IL2RG) and prion, we diffused binders to beta strand conformations of the targets, obtaining 10 to 100 nM affinity. The IL2RG binder colocalizes with the receptor in cells, enabling new approaches to modulating IL2 signaling. Our approach should be widely useful for creating binders to flexible IDPs/IDRs spanning a wide range of intrinsic conformational preferences.

4.
Clin Chim Acta ; 560: 119756, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38825058

RESUMO

BACKGROUND: Iron studies are critical for diagnosing iron deficiency and hemochromatosis. We present a case exhibiting macrocytic anemia with perplexingly high plasma iron concentrations. METHODS AND RESULTS: The initial clinical presentation with significantly elevated iron results raised concerns for hemochromatosis. However, inconsistent results in dilution studies suggested the presence of an interfering substance. Inspection of the reaction curves from the instrument revealed very high background absorption in the 800 nm channel. This, coupled with the observation of an insoluble precipitate upon mixing the acid buffer reagent with the patient's serum, as well as the patient's high total protein and low albumin levels, suggested immunoglobulin overproduction. Serum protein electrophoresis confirmed a monoclonal gammopathy with a subsequent diagnosis of multiple myeloma. CONCLUSION: Excessive monoclonal immunoglobulins can precipitate in acidic buffers and interfere with spectrophotometric measurements in iron testing. Although challenging, investigating an interference and determining its cause can uncover underlying diseases that have yet to be diagnosed.


Assuntos
Ferro , Mieloma Múltiplo , Humanos , Mieloma Múltiplo/diagnóstico , Mieloma Múltiplo/sangue , Ferro/sangue , Masculino
5.
Front Neurol ; 15: 1385623, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38765262

RESUMO

Background: Sphingolipids are implicated in neurodegeneration and neuroinflammation. We assessed the potential role of circulating ceramides and sphingomyelins in subclinical brain pathology by investigating their association with brain magnetic resonance imaging (MRI) measures and circulating biomarkers of brain injury, neurofilament light chain (NfL) and glial fibrillary acidic protein (GFAP) in the Cardiovascular Health Study (CHS), a large and intensively phenotyped cohort of older adults. Methods: Brain MRI was offered twice to CHS participants with a mean of 5 years between scans, and results were available from both time points in 2,116 participants (mean age 76 years; 40% male; and 25% APOE ε4 allele carriers). We measured 8 ceramide and sphingomyelin species in plasma samples and examined the associations with several MRI, including worsening grades of white matter hyperintensities and ventricular size, number of brain infarcts, and measures of brain atrophy in a subset with quantitative measures. We also investigated the sphingolipid associations with serum NfL and GFAP. Results: In the fully adjusted model, higher plasma levels of ceramides and sphingomyelins with a long (16-carbon) saturated fatty acid were associated with higher blood levels of NfL [ß = 0.05, false-discovery rate corrected P (PFDR) = 0.004 and ß = 0.06, PFDR = < 0.001, respectively]. In contrast, sphingomyelins with very long (20- and 22-carbon) saturated fatty acids tended to have an inverse association with levels of circulating NfL. In secondary analyses, we found an interaction between ceramide d18:1/20:0 and sex (P for interaction = <0.001), such that ceramide d18:1/20:0 associated with higher odds for infarcts in women [OR = 1.26 (95%CI: 1.07, 1.49), PFDR = 0.03]. We did not observe any associations with GFAP blood levels, white matter grade, ventricular grade, mean bilateral hippocampal volume, or total brain volume. Conclusion: Overall, our comprehensive investigation supports the evidence that ceramides and sphingomyelins are associated with increased aging brain pathology and that the direction of association depends on the fatty acid attached to the sphingosine backbone.

6.
bioRxiv ; 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38617345

RESUMO

Membrane-bound particles in plasma are composed of exosomes, microvesicles, and apoptotic bodies and represent ~1-2% of the total protein composition. Proteomic interrogation of this subset of plasma proteins augments the representation of tissue-specific proteins, representing a "liquid biopsy," while enabling the detection of proteins that would otherwise be beyond the dynamic range of liquid chromatography-tandem mass spectrometry of unfractionated plasma. We have developed an enrichment strategy (Mag-Net) using hyper-porous strong-anion exchange magnetic microparticles to sieve membrane-bound particles from plasma. The Mag-Net method is robust, reproducible, inexpensive, and requires <100 µL plasma input. Coupled to a quantitative data-independent mass spectrometry analytical strategy, we demonstrate that we can collect results for >37,000 peptides from >4,000 plasma proteins with high precision. Using this analytical pipeline on a small cohort of patients with neurodegenerative disease and healthy age-matched controls, we discovered 204 proteins that differentiate (q-value < 0.05) patients with Alzheimer's disease dementia (ADD) from those without ADD. Our method also discovered 310 proteins that were different between Parkinson's disease and those with either ADD or healthy cognitively normal individuals. Using machine learning we were able to distinguish between ADD and not ADD with a mean ROC AUC = 0.98 ± 0.06.

7.
bioRxiv ; 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38645098

RESUMO

A thorough evaluation of the quality, reproducibility, and variability of bottom-up proteomics data is necessary at every stage of a workflow from planning to analysis. We share real-world case studies applying adaptable quality control (QC) measures to assess sample preparation, system function, and quantitative analysis. System suitability samples are repeatedly measured longitudinally with targeted methods, and we share examples where they are used on three instrument platforms to identify severe system failures and track function over months to years. Internal QCs incorporated at protein and peptide-level allow our team to assess sample preparation issues and to differentiate system failures from sample-specific issues. External QC samples prepared alongside our experimental samples are used to verify the consistency and quantitative potential of our results during batch correction and normalization before assessing biological phenotypes. We combine these controls with rapid analysis using Skyline, longitudinal QC metrics using AutoQC, and server-based data deposition using PanoramaWeb. We propose that this integrated approach to QC be used as a starting point for groups to facilitate rapid quality control assessment to ensure that valuable instrument time is used to collect the best quality data possible.

8.
Clin Chem ; 70(6): 855-864, 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38549041

RESUMO

BACKGROUND: The enhanced precision and selectivity of liquid chromatography-tandem mass spectrometry (LC-MS/MS) makes it an attractive alternative to certain clinical immunoassays. Easily transferrable work flows could help facilitate harmonization and ensure high-quality patient care. We aimed to evaluate the interlaboratory comparability of antibody-free multiplexed insulin and C-peptide LC-MS/MS measurements. METHODS: The laboratories that comprise the Targeted Mass Spectrometry Assays for Diabetes and Obesity Research (TaMADOR) consortium verified the performance of a validated peptide-based assay (reproducibility, linearity, and lower limit of the measuring interval [LLMI]). An interlaboratory comparison study was then performed using shared calibrators, de-identified leftover laboratory samples, and reference materials. RESULTS: During verification, the measurements were precise (2.7% to 3.7%CV), linear (4 to 15 ng/mL for C-peptide and 2 to 14 ng/mL for insulin), and sensitive (LLMI of 0.04 to 0.10 ng/mL for C-peptide and 0.03 ng/mL for insulin). Median imprecision across the 3 laboratories was 13.4% (inter-quartile range [IQR] 11.6%) for C-peptide and 22.2% (IQR 20.9%) for insulin using individual measurements, and 10.8% (IQR 8.7%) and 15.3% (IQR 14.9%) for C-peptide and insulin, respectively, when replicate measurements were averaged. Method comparison with the University of Missouri reference method for C-peptide demonstrated a robust linear correlation with a slope of 1.044 and r2 = 0.99. CONCLUSIONS: Our results suggest that combined LC-MS/MS measurements of C-peptide and insulin are robust and adaptable and that standardization with a reference measurement procedure could allow accurate and precise measurements across sites, which could be important to diabetes research and help patient care in the future.


Assuntos
Peptídeo C , Insulina , Espectrometria de Massas em Tandem , Peptídeo C/sangue , Peptídeo C/análise , Humanos , Espectrometria de Massas em Tandem/métodos , Insulina/análise , Insulina/sangue , Cromatografia Líquida/métodos , Reprodutibilidade dos Testes , Laboratórios/normas , Espectrometria de Massa com Cromatografia Líquida
9.
J Bone Miner Res ; 39(4): 433-442, 2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38477777

RESUMO

Fracture risk is high in chronic kidney disease (CKD) and underlying pathophysiology and risk factors may differ from the general population. In a cohort study of 3939 participants in the chronic renal insufficiency cohort (CRIC), we used Cox regression to test associations of putative risk factors with the composite of first hip or vertebral fracture assessed using hospital discharge codes. Mean age was 58 years, 45% were female, 42% were Black, and 13% were Hispanic. There were 82 hip and 24 vertebral fractures over a mean (SD) 11.1 (4.8) years (2.4 events per 1000 person-years [95% CI: 2.0, 2.9]). Measured at baseline, diabetes, lower body mass index (BMI), steroid use, proteinuria, and elevated parathyroid hormone (PTH) were each associated with fracture risk after adjusting for covariates. Lower time-updated estimated glomerular filtration rate (eGFR) was associated with fractures (HR 1.20 per 10 mL/min/1.73m2 lower eGFR; 95% CI: 1.04, 1.38) as were lower time-updated serum calcium and bicarbonate concentrations. Among time-updated categories of kidney function, hazard ratios (95% CI) for incident fracture were 4.53 (1.77, 11.60) for kidney failure treated with dialysis and 2.48 (0.86, 7.14) for post-kidney transplantation, compared with eGFR ≥60. Proton pump inhibitor use, dietary calcium intake, measures of vitamin D status, serum phosphate, urine calcium and phosphate, and plasma fibroblast growth factor-23 were not associated with fracture risk. In conclusion, lower eGFR in CKD is associated with higher fracture risk, which was highest in kidney failure. Diabetes, lower BMI, steroid use, proteinuria, higher serum concentrations of PTH, and lower calcium and bicarbonate concentrations were associated with fractures and may be modifiable risk factors.


People with chronic kidney disease are at high risk of fractures. Our research assessed the relationship between several patient characteristics and the risk of fractures in 3939 patients with chronic kidney disease. We found that the following characteristics were associated with a higher risk of a hip or spine fracture: having diabetes, lower body mass index, use of steroid-containing medications, lower kidney filtration rate ("eGFR"), higher amounts of protein spilled in the urine, lower calcium and bicarbonate levels, and higher parathyroid hormone levels. Future studies should assess if improving these characteristics decreases the risk of fractures in patients with chronic kidney disease.


Assuntos
Fraturas do Quadril , Insuficiência Renal Crônica , Fraturas da Coluna Vertebral , Humanos , Feminino , Masculino , Fatores de Risco , Pessoa de Meia-Idade , Insuficiência Renal Crônica/sangue , Insuficiência Renal Crônica/complicações , Insuficiência Renal Crônica/epidemiologia , Fraturas do Quadril/epidemiologia , Fraturas do Quadril/sangue , Fraturas da Coluna Vertebral/epidemiologia , Fraturas da Coluna Vertebral/sangue , Idoso , Fator de Crescimento de Fibroblastos 23 , Taxa de Filtração Glomerular
11.
Clin Proteomics ; 21(1): 12, 2024 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-38389054

RESUMO

Mass spectrometry (MS) assays offer exceptional capabilities in high multiplexity, specificity, and throughput. As proteomics technologies continue advancements to identify new disease biomarkers, transition of these innovations from research settings to clinical applications becomes imperative. To meet the rigorous regulatory standards of clinical laboratories, development of a clinical protein MS assay necessitates adherence to stringent criteria. To illustrate the process, this project focused on using thyroglobulin (Tg) as a biomarker and an immuno-multiple reaction monitoring (iMRM) MS-based assay as a model for establishing a Clinical Laboratory Improvement Amendments (CLIA) compliant laboratory within the Centers of Genomic and Precision Medicine, National Taiwan University. The chosen example also illustrates the clinical utility of MS assays to complement conventional immunoassay-based methods, particularly in cases where the presence of autoantibodies in 10-30% of patients hinders accuracy. The laboratory design entails a comprehensive coordination in spatial layout, workflow organization, equipment selection, ventilation systems, plumbing, electrical infrastructure, documentation procedures, and communication protocols. Practical aspects of the transformation process, including preparing laboratory facilities, testing environments, instrument validation, assay development and validation, quality management, sample testing, and personnel competency, are discussed. Finally, concordant results in proficiency testing demonstrate the harmonization with the University of Washington Medical Center and the quality assurance of the CLIA-equivalent Tg-iMRM MS assay established in Taiwan. The realization of this model protein MS assay in Taiwan highlights the feasibility of international joint development and provides a detailed reference map to expedite the implementation of more MS-based protein assays in clinical laboratories for patient care.

12.
ESC Heart Fail ; 11(3): 1435-1442, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38407565

RESUMO

AIMS: Among persons with prevalent heart failure (HF), iron deficiency has been linked to HF admissions, and intravenous iron replacement improves HF outcomes. Recent studies in persons with chronic kidney disease (CKD) demonstrate that iron deficiency is associated with incident HF. This study aimed to determine the relationship of iron status with incident HF in community-dwelling older adults irrespective of their kidney function. METHODS: In this case-cohort study, 1,006 Cardiovascular Health Study participants (785 from the random sub-cohort [including 193 HF cases] and 221 additional HF cases [N = 414 total HF cases]) aged ≥ 65 years without HF (41% with CKD), we used weighted Cox models to evaluate associations of iron status with incident HF. Participants were categorized based on quartiles of transferrin saturation and ferritin as "iron replete" (27.3%), "functional iron deficiency" (7.7%), "iron deficiency" (11.8%), "mixed iron deficiency" (5.6%), "high iron" (9.3%) and "non-classified" (38.1%), consistent with prior studies. RESULTS: Compared to older persons who were iron replete, those with iron deficiency were at higher risk of incident HF (HR 1.47; 1.02-2.11) in models adjusting for demographics, HF risk factors, and estimated glomerular filtration rate. Other iron categories did not associate with incident HF. The relationship of iron deficiency with incident HF did not differ by CKD status (interaction P value 0.2). CONCLUSIONS: Among community-dwelling elders, iron deficiency is independently associated with incident HF, an association that was similar irrespective of CKD status. Our findings support conduct of clinical trials of iron replacement for prevention of HF in older adults with iron deficiency.


Assuntos
Insuficiência Cardíaca , Vida Independente , Deficiências de Ferro , Humanos , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/sangue , Insuficiência Cardíaca/complicações , Idoso , Feminino , Masculino , Incidência , Anemia Ferropriva/epidemiologia , Anemia Ferropriva/sangue , Anemia Ferropriva/complicações , Estados Unidos/epidemiologia , Fatores de Risco , Seguimentos , Idoso de 80 Anos ou mais , Ferro/sangue
14.
Am J Nephrol ; 55(2): 187-195, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38128487

RESUMO

INTRODUCTION: Fibroblast growth factor 23 (FGF23) has direct effects on the vasculature and myocardium, and high levels of FGF23 are a risk factor for cardiovascular disease (CVD); however, the impact of FGF23 on CVD in primary proteinuric glomerulopathies has not been addressed. METHODS: The associations of baseline plasma intact FGF23 levels with resting blood pressure (BP) and lipids over time among adults and children with proteinuric glomerulopathies enrolled in the Nephrotic Syndrome Study Network (NEPTUNE) were analyzed using generalized estimating equation regression analyses. Models were adjusted for age, sex, glomerular diagnosis, follow-up time, estimated glomerular filtration rate, urine protein/creatinine ratio, obesity, and serum phosphorous levels. RESULTS: Two hundred and four adults with median FGF23 77.5 (IQR 51.3-119.3) pg/mL and 93 children with median FGF23 62.3 (IQR 44.6-83.6) pg/mL were followed for a median of 42 (IQR 20.5-54) months. In adjusted models, each 1 µg/mL increase in FGF23 was associated with a 0.3 increase in systolic BP index at follow-up (p < 0.001). Greater baseline FGF23 was associated with greater odds of hypertensive BP (OR = 1.0003; 95% CI 1.001-1.006, p = 0.03) over time. Compared to tertile 1, tertile 2 (OR = 2.1; 95% CI 1.12-3.99, p = 0.02), and tertile 3 (OR = 3; 95% CI 1.08-8.08, p = 0.04), FGF23 levels were associated with greater odds of hypertensive BP over time. Tertile 2 was associated with greater triglycerides compared to tertile 1 (OR = 48.1; 95% CI 4.4-91.9, p = 0.03). CONCLUSION: Overall, higher baseline FGF23 was significantly associated with hypertensive BP over time in individuals with proteinuric glomerulopathies. Further study of FGF23 as a therapeutic target for reducing CVD in proteinuric glomerular disease is warranted.


Assuntos
Doenças Cardiovasculares , Hipertensão , Adulto , Criança , Humanos , Pressão Sanguínea/fisiologia , Fator de Crescimento de Fibroblastos 23 , Fatores de Crescimento de Fibroblastos , Fatores de Risco
15.
Nature ; 626(7998): 435-442, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38109936

RESUMO

Many peptide hormones form an α-helix on binding their receptors1-4, and sensitive methods for their detection could contribute to better clinical management of disease5. De novo protein design can now generate binders with high affinity and specificity to structured proteins6,7. However, the design of interactions between proteins and short peptides with helical propensity is an unmet challenge. Here we describe parametric generation and deep learning-based methods for designing proteins to address this challenge. We show that by extending RFdiffusion8 to enable binder design to flexible targets, and to refining input structure models by successive noising and denoising (partial diffusion), picomolar-affinity binders can be generated to helical peptide targets by either refining designs generated with other methods, or completely de novo starting from random noise distributions without any subsequent experimental optimization. The RFdiffusion designs enable the enrichment and subsequent detection of parathyroid hormone and glucagon by mass spectrometry, and the construction of bioluminescence-based protein biosensors. The ability to design binders to conformationally variable targets, and to optimize by partial diffusion both natural and designed proteins, should be broadly useful.


Assuntos
Desenho Assistido por Computador , Aprendizado Profundo , Peptídeos , Proteínas , Técnicas Biossensoriais , Difusão , Glucagon/química , Glucagon/metabolismo , Medições Luminescentes , Espectrometria de Massas , Hormônio Paratireóideo/química , Hormônio Paratireóideo/metabolismo , Peptídeos/química , Peptídeos/metabolismo , Estrutura Secundária de Proteína , Proteínas/química , Proteínas/metabolismo , Especificidade por Substrato , Modelos Moleculares
16.
Kidney Int ; 105(3): 629-637, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38101514

RESUMO

Estimating glomerular filtration rate (GFR) is important in daily practice to assess kidney function and adapting the best clinical care of patients with and without chronic kidney disease. The new creatinine-based European Kidney Function Consortium (EKFC) equation is used to estimate GFR. This equation was developed and validated mainly in European individuals and based on a rescaled creatinine, with the rescaling factor (Q-value) defined as the median normal value of serum creatinine in a given population. The validation was limited in Non-Black Americans and absent in Black Americans. Here, our cross-sectional analysis included 12,854 participants from nine studies encompassing large numbers of both non-Black and Black Americans with measured GFR by clearance of an exogenous marker (reference method), serum creatinine, age, sex, and self-reported race available. Two strategies were considered with population-specific Q-values in Black and non-Black men and women (EKFCPS) or a race-free Q-value (EKFCRF). In the whole population, only the EKFCPS equation showed no statistical median bias (0.14, 95% confidence interval [-0.07; 0.35] mL/min/1.73m2), and the bias for the EKFCRF (0.74, [0.51; 0.94] mL/min/1.73m2) was closer to zero than that for the Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI2021) equation (1.22, [0.99; 1.47]) mL/min/1.73m2]. The percentage of estimated GFR within 30% of measured GFR was similar for CKD-EPI2021 (79.2% [78.5%; 79.9%]) and EKFCRF (80.1% [79.4%; 80.7%]), but improved for the EKFCPS equation (81.1% [80.5%; 81.8%]). Thus, our EKFC equations can be used to estimate GFR in the United States incorporating either self-reported race or unknown race at the patient's discretion per hospital registration records.


Assuntos
Cistatina C , Insuficiência Renal Crônica , Masculino , Humanos , Feminino , Estados Unidos , Creatinina , Estudos Transversais , Taxa de Filtração Glomerular , Rim
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...