1.
Biomedicines ; 12(6)2024 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-38927543

RESUMO

Cardiac xenotransplantation has seen remarkable success in recent years and is emerging as the most promising alternative to human cardiac allotransplantation. Despite these achievements, acute vascular rejection still presents a challenge for long-term xenograft acceptance and new insights into innate and adaptive immune responses as well as detailed characterizations of signaling pathways are necessary. In allotransplantation, endothelial cells and their sugar-rich surface-the endothelial glycocalyx-are known to influence organ rejection. In xenotransplantation, however, only in vitro data exist on the role of the endothelial glycocalyx so far. Thus, in the current study, we analyzed the changes of the endothelial glycocalyx components hyaluronan, heparan sulfate and syndecan-1 after pig-to-baboon cardiac xenotransplantations in the perioperative (n = 4) and postoperative (n = 5) periods. These analyses provide first insights into changes of the endothelial glycocalyx after pig-to-baboon cardiac xenotransplantation and show that damage to the endothelial glycocalyx seems to be comparable or even less pronounced than in similar human settings when current strategies of cardiac xenotransplantation are applied. At the same time, data from the experiments where current strategies, like non-ischemic preservation, growth inhibition or porcine cytomegalovirus (a porcine roseolovirus (PCMV/PRV)) elimination could not be applied indicate that damage of the endothelial glycocalyx also plays an important role in cardiac xenotransplantation.

2.
Transplantation ; 107(12): e328-e338, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37643028

RESUMO

BACKGROUND: Orthotopic cardiac xenotransplantation has seen substantial advancement in the last years and the initiation of a clinical pilot study is close. However, donor organ overgrowth has been a major hurdle for preclinical experiments, resulting in loss of function and the decease of the recipient. A better understanding of the pathogenesis of organ overgrowth after xenotransplantation is necessary before clinical application. METHODS: Hearts from genetically modified ( GGTA1-KO , hCD46/hTBM transgenic) juvenile pigs were orthotopically transplanted into male baboons. Group I (control, n = 3) received immunosuppression based on costimulation blockade, group II (growth inhibition, n = 9) was additionally treated with mechanistic target of rapamycin inhibitor, antihypertensive medication, and fast corticoid tapering. Thyroid hormones and insulin-like growth factor 1 were measured before transplantation and before euthanasia, left ventricular (LV) growth was assessed by echocardiography, and hemodynamic data were recorded via a wireless implant. RESULTS: Insulin-like growth factor 1 was higher in baboons than in donor piglets but dropped to porcine levels at the end of the experiments in group I. LV mass increase was 10-fold faster in group I than in group II. This increase was caused by nonphysiological LV wall enlargement. Additionally, pressure gradients between LV and the ascending aorta developed, and signs of dynamic left ventricular outflow tract (LVOT) obstruction appeared. CONCLUSIONS: After orthotopic xenotransplantation in baboon recipients, untreated porcine hearts showed rapidly progressing concentric hypertrophy with dynamic LVOT obstruction, mimicking hypertrophic obstructive cardiomyopathy in humans. Antihypertensive and antiproliferative drugs reduced growth rate and inhibited LVOT obstruction, thereby preventing loss of function.


Assuntos
Transplante de Coração , Obstrução da Via de Saída Ventricular Esquerda , Humanos , Animais , Masculino , Suínos , Xenoenxertos , Transplante Heterólogo/métodos , Papio , Fator de Crescimento Insulin-Like I , Anti-Hipertensivos , Projetos Piloto , Hipertrofia Ventricular Esquerda , Transplante de Coração/efeitos adversos , Transplante de Coração/métodos
3.
Artif Organs ; 46(9): 1794-1803, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35548921

RESUMO

BACKGROUND: Existing working heart models for ex vivo functional evaluation of donor hearts often use cardiac afterloads made up of discrete resistive and compliant elements. This approach limits the practicality of independently controlling systolic and diastolic aortic pressure to safely test the heart under multiple loading conditions. We present and investigate a novel afterload concept designed to enable such control. METHODS: Six ∼70 kg pig hearts were evaluated in vivo, then ex vivo in left-ventricular working mode using the presented afterload. Both in vivo and ex vivo, the hearts were evaluated at two exertion levels: at rest and following a 20 µg adrenaline bolus, while measuring aortic pressure and flow, left ventricular pressure and volume, and left atrial pressure. RESULTS: The afterload gave aortic pressure waveforms that matched the general shape of the in vivo measurements. A wide range of physiological systolic pressures (93 to 160 mm Hg) and diastolic pressures (73 to 113 mm Hg) were generated by the afterload. CONCLUSIONS: With the presented afterload concept, multiple physiological loading conditions could be tested ex vivo, and compared with the corresponding in vivo data. An additional control loop from the set pressure limits to the measured systolic and diastolic aortic pressure is proposed to address discrepancies observed between the set limits and the measured pressures.


Assuntos
Transplante de Coração , Animais , Coração/fisiologia , Humanos , Contração Miocárdica , Perfusão/métodos , Suínos , Doadores de Tecidos , Função Ventricular Esquerda/fisiologia
4.
Xenotransplantation ; 28(1): e12636, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32841431

RESUMO

BACKGROUND: Successful preclinical transplantations of porcine hearts into baboon recipients are required before commencing clinical trials. Despite years of research, over half of the orthotopic cardiac xenografts were lost during the first 48 hours after transplantation, primarily caused by perioperative cardiac xenograft dysfunction (PCXD). To decrease the rate of PCXD, we adopted a preservation technique of cold non-ischemic perfusion for our ongoing pig-to-baboon cardiac xenotransplantation project. METHODS: Fourteen orthotopic cardiac xenotransplantation experiments were carried out with genetically modified juvenile pigs (GGTA1- KO/hCD46/hTBM) as donors and captive-bred baboons as recipients. Organ preservation was compared according to the two techniques applied: cold static ischemic cardioplegia (IC; n = 5) and cold non-ischemic continuous perfusion (CP; n = 9) with an oxygenated albumin-containing hyperoncotic cardioplegic solution containing nutrients, erythrocytes and hormones. Prior to surgery, we measured serum levels of preformed anti-non-Gal-antibodies. During surgery, hemodynamic parameters were monitored with transpulmonary thermodilution. Central venous blood gas analyses were taken at regular intervals to estimate oxygen extraction, as well as lactate production. After surgery, we measured troponine T and serum parameters of the recipient's kidney, liver and coagulation functions. RESULTS: In porcine grafts preserved with IC, we found significantly depressed systolic cardiac function after transplantation which did not recover despite increasing inotropic support. Postoperative oxygen extraction and lactate production were significantly increased. Troponin T, creatinine, aspartate aminotransferase levels were pathologically high, whereas prothrombin ratios were abnormally low. In three of five IC experiments, PCXD developed within 24 hours. By contrast, all nine hearts preserved with CP retained fully preserved systolic function, none showed any signs of PCXD. Oxygen extraction was within normal ranges; serum lactate as well as parameters of organ functions were only mildly elevated. Preformed anti-non-Gal-antibodies were similar in recipients receiving grafts from either IC or CP preservation. CONCLUSIONS: While standard ischemic cardioplegia solutions have been used with great success in human allotransplantation over many years, our data indicate that they are insufficient for preservation of porcine hearts transplanted into baboons: Ischemic storage caused severe impairment of cardiac function and decreased tissue oxygen supply, leading to multi-organ failure in more than half of the xenotransplantation experiments. In contrast, cold non-ischemic heart preservation with continuous perfusion reliably prevented early graft failure. Consistent survival in the perioperative phase is a prerequisite for preclinical long-term results after cardiac xenotransplantation.


Assuntos
Transplante de Coração , Animais , Xenoenxertos , Papio , Perfusão , Suínos , Transplante Heterólogo
5.
J Heart Lung Transplant ; 39(8): 751-757, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32527674

RESUMO

BACKGROUND: The demand for donated human hearts far exceeds the number available. Xenotransplantation of genetically modified porcine organs provides an alternative. In 2000, an Advisory Board of the International Society for Heart and Lung Transplantation set the benchmark for commencing clinical cardiac xenotransplantation as consistent 60% survival of non-human primates after life-supporting porcine heart transplantations. Recently, we reported the stepwise optimization of pig-to-baboon orthotopic cardiac xenotransplantation finally resulting in consistent success, with 4 recipients surviving 90 (n = 2), 182, and 195 days. Here, we report on 4 additional recipients, supporting the efficacy of our procedure. RESULTS: The first 2 additional recipients succumbed to porcine cytomegalovirus (PCMV) infections on Days 15 and 27, respectively. In 2 further experiments, PCMV infections were successfully avoided, and 3-months survival was achieved. Throughout all the long-term experiments, heart, liver, and renal functions remained within normal ranges. Post-mortem cardiac diameters were slightly increased when compared with that at the time of transplantation but with no detrimental effect. There were no signs of thrombotic microangiopathy. The current regimen enabled the prolonged survival and function of orthotopic cardiac xenografts in altogether 6 of 8 baboons, of which 4 were now added. These results exceed the threshold set by the Advisory Board of the International Society for Heart and Lung Transplantation. CONCLUSIONS: The results of our current and previous experimental cardiac xenotransplantations together fulfill for the first time the pre-clinical efficacy suggestions. PCMV-positive donor animals must be avoided.


Assuntos
Rejeição de Enxerto/etiologia , Transplante de Coração/métodos , Doadores de Tecidos , Animais , Sobrevivência de Enxerto , Humanos , Suínos , Transplante Heterólogo
6.
Nat Commun ; 11(1): 2976, 2020 06 12.
Artigo em Inglês | MEDLINE | ID: mdl-32532991

RESUMO

Pre-clinical heart transplantation studies have shown that ex vivo non-ischemic heart preservation (NIHP) can be safely used for 24 h. Here we perform a prospective, open-label, non-randomized phase II study comparing NIHP to static cold preservation (SCS), the current standard for adult heart transplantation. All adult recipients on waiting lists for heart transplantation were included in the study, unless they met any exclusion criteria. The same standard acceptance criteria for donor hearts were used in both study arms. NIHP was scheduled in advance based on availability of device and trained team members. The primary endpoint was a composite of survival free of severe primary graft dysfunction, free of ECMO use within 7 days, and free of acute cellular rejection ≥2R within 180 days. Secondary endpoints were I/R-tissue injury, immediate graft function, and adverse events. Of the 31 eligible patients, six were assigned to NIHP and 25 to SCS. The median preservation time was 223 min (IQR, 202-263) for NIHP and 194 min (IQR, 164-223) for SCS. Over the first six months, all of the patients assigned to NIHP achieved event-free survival, compared with 18 of those assigned to SCS (Kaplan-Meier estimate of event free survival 72.0% [95% CI 50.0-86.0%]). CK-MB assessed 6 ± 2 h after ending perfusion was 76 (IQR, 50-101) ng/mL for NIHP compared with 138 (IQR, 72-198) ng/mL for SCS. Four deaths within six months after transplantation and three cardiac-related adverse events were reported in the SCS group compared with no deaths or cardiac-related adverse events in the NIHP group. This first-in-human study shows the feasibility and safety of NIHP for clinical use in heart transplantation. ClinicalTrial.gov, number NCT03150147.


Assuntos
Criopreservação/métodos , Transplante de Coração/métodos , Ensaios Clínicos Controlados não Aleatórios como Assunto , Preservação de Órgãos/métodos , Adulto , Idoso , Feminino , Rejeição de Enxerto , Transplante de Coração/instrumentação , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde/métodos , Avaliação de Resultados em Cuidados de Saúde/estatística & dados numéricos , Perfusão , Estudos Prospectivos , Fatores de Tempo , Doadores de Tecidos , Listas de Espera
8.
Resuscitation ; 138: 215-221, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30862527

RESUMO

PURPOSE: It has previously been shown that continuous intratracheal insufflation of oxygen (CIO) is superior to intermittent positive pressure ventilation (IPPV) regarding gas exchange and haemodynamics. The purpose of this study was to investigate gas exchange and haemodynamics with a new technique of phase-controlled intermittent insufflation of oxygen (PIIO) compared to CIO. METHOD: Twenty (20) pigs were used, stratified into two groups (CIO, PIIO), with 10 animals each. Upon induction of ventricular fibrillation, standard ventilator support was replaced by either of CIO or PIIO ventilation. Chest compressions were delivered by the LUCAS I mCPR device. Following 20 min of CPR in normothermia, defibrillation was attempted. RESULTS: Return of spontaneous circulation (ROSC) occurrence was not significantly higher (P < 0.16) in the PIIO (9/10) than in the CIO (6/10) group. During the decompression phase the PIIO group showed significant increases in mean (P < 0.01), maximal (P < 0.02) and end-decompression (P < 0.01) coronary perfusion pressure (CPP), compared to the CIO group. PIIO resulted in increased compression phase aortic pressure (P < 0.03). Intratracheal pressure was 5-30 cmH2O within both groups during mCPR, with a significantly lower (P < 0.02) mean for the PIIO group. Arterial and venous blood gas analysis showed comparable results between the groups, when taking base line values into account. An exception was that PIIO resulted in significantly higher (P < 0.05) oxygen partial pressure during mCPR, and lower (P < 0.05) arterial lactate following ROSC. CONCLUSION: PIIO results in significantly higher CPP and compression phase aortic pressure during mCPR in a porcine population. Further studies are needed to validate these findings in humans. Study protocol conforming with ethic approval M174-15, issued by the Malmö/Lunds regionala djurförsöksetiska nämnd (REB).


Assuntos
Circulação Coronária/fisiologia , Descompressão/métodos , Parada Cardíaca/terapia , Massagem Cardíaca/métodos , Insuflação/métodos , Ventilação com Pressão Positiva Intermitente/métodos , Fibrilação Ventricular/complicações , Animais , Modelos Animais de Doenças , Parada Cardíaca/etiologia , Parada Cardíaca/fisiopatologia , Pressão , Suínos , Fibrilação Ventricular/fisiopatologia
9.
Nature ; 564(7736): 430-433, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30518863

RESUMO

Heart transplantation is the only cure for patients with terminal cardiac failure, but the supply of allogeneic donor organs falls far short of the clinical need1-3. Xenotransplantation of genetically modified pig hearts has been discussed as a potential alternative4. Genetically multi-modified pig hearts that lack galactose-α1,3-galactose epitopes (α1,3-galactosyltransferase knockout) and express a human membrane cofactor protein (CD46) and human thrombomodulin have survived for up to 945 days after heterotopic abdominal transplantation in baboons5. This model demonstrated long-term acceptance of discordant xenografts with safe immunosuppression but did not predict their life-supporting function. Despite 25 years of extensive research, the maximum survival of a baboon after heart replacement with a porcine xenograft was only 57 days and this was achieved, to our knowledge, only once6. Here we show that α1,3-galactosyltransferase-knockout pig hearts that express human CD46 and thrombomodulin require non-ischaemic preservation with continuous perfusion and control of post-transplantation growth to ensure long-term orthotopic function of the xenograft in baboons, the most stringent preclinical xenotransplantation model. Consistent life-supporting function of xenografted hearts for up to 195 days is a milestone on the way to clinical cardiac xenotransplantation7.


Assuntos
Transplante de Coração , Xenoenxertos/transplante , Papio , Suínos , Transplante Heterólogo , Animais , Anticorpos/análise , Anticorpos/sangue , Proteínas do Sistema Complemento/análise , Enzimas/sangue , Fibrina/análise , Galactosiltransferases/deficiência , Galactosiltransferases/genética , Xenoenxertos/patologia , Humanos , Fígado/enzimologia , Masculino , Proteína Cofatora de Membrana/genética , Proteína Cofatora de Membrana/metabolismo , Miocárdio/enzimologia , Necrose , Perfusão , Contagem de Plaquetas , Tempo de Protrombina , Trombomodulina/genética , Trombomodulina/metabolismo , Fatores de Tempo
10.
J Clin Monit Comput ; 32(3): 429-437, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28602010

RESUMO

The purpose of this concept study was to investigate the possibility of automatic mean arterial pressure (MAP) regulation in a porcine heart-beating brain death (BD) model. Hemodynamic stability of BD donors is necessary for maintaining acceptable quality of donated organs for transplantation. Manual stabilization is challenging, due to the lack of vasomotor function in BD donors. Closed-loop stabilization therefore has the potential of increasing availability of acceptable donor organs, and serves to indicate feasibility within less demanding patient groups. A dynamic model of nitroglycerine pharmacology, suitable for controller synthesis, was identified from an experiment involving an anesthetized pig, using a gradient-based output error method. The model was used to synthesize a robust PID controller for hypertension prevention, evaluated in a second experiment, on a second, brain dead, pig. Hypotension was simultaneously prevented using closed-loop controlled infusion of noradrenaline, by means of a previously published controller. A linear model of low order, with variable (uncertain) gain, was sufficient to describe the dynamics to be controlled. The robustly tuned PID controller utilized in the second experiment kept the MAP within a user-defined range. The system was able to prevent hypertension, exceeding a reference of 100 mmHg by more than 10%, during 98% of a 12 h experiment. This early work demonstrates feasibility of the investigated modelling and control synthesis approach, for the purpose of maintaining normotension in a porcine BD model. There remains a need to characterize individual variability, in order to ensure robust performance over the expected population.


Assuntos
Anestesia com Circuito Fechado/métodos , Pressão Arterial , Morte Encefálica , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Animais , Gasometria , Hemodinâmica , Humanos , Hipertensão , Hipotensão , Modelos Animais , Contração Miocárdica , Suínos
11.
IEEE Trans Biomed Eng ; 64(6): 1310-1317, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-27576237

RESUMO

Objective: The purpose of this paper is to demonstrate feasibility of a novel closed-loop controlled therapy for prevention of hypertension in the heartbeating brain-dead porcine model. METHODS: Dynamic modeling and system identification were based on in vivo data. A robust controller design was obtained for the identified models. Disturbance attenuation properties and reliability of operation of the resulting control system were evaluated in vivo. RESULTS: The control system responded both predictably and consistently to external disturbances. It was possible to prevent mean arterial pressure to fall below a user-specified reference throughout 24 h of completely autonomous operation. CONCLUSION: Parameter variability in the identified models confirmed the benefit of closed-loop controlled administration of the proposed therapy. The evaluated robust controller was able to mitigate both process uncertainty and external disturbances. SIGNIFICANCE: Prevention of hypertension is critical to the care of heartbeating brain-dead organ donors. Its automation would likely increase the fraction of organs suitable for transplantation from this patient group.


Assuntos
Morte Encefálica/fisiopatologia , Quimioterapia Assistida por Computador/métodos , Hipotensão/tratamento farmacológico , Hipotensão/prevenção & controle , Modelos Biológicos , Simpatomiméticos/administração & dosagem , Animais , Simulação por Computador , Estudos de Viabilidade , Retroalimentação , Suínos , Coleta de Tecidos e Órgãos/métodos , Resultado do Tratamento
12.
Scand Cardiovasc J ; 50(3): 193-200, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26882241

RESUMO

OBJECTIVES: The aim of this study was to demonstrate safe orthotopic transplantation of porcine donor hearts harvested 24 hours after brain death and preserved for 24 hours before transplantation. DESIGN: Circulatory normalization of brain dead (decapitated) pigs was obtained using a new pharmacological regimen (n = 10). The donor hearts were perfused at 8 °C in cycles of 15 min perfusion followed by 60 min without perfusion. The perfusate consisted of an albumin-containing hyperoncotic cardioplegic nutrition solution with hormones and erythrocytes. Orthotopic transplantation was done in 10 recipient pigs after 24 hours' preservation. Transplanted pigs were monitored for 24 hours, then an adrenaline stress test was done. RESULTS: All transplanted pigs were stable throughout the 24-hour observation period with mean aortic pressure around 80 mmHg and normal urine production. Mean right and left atrial pressures were in the range of 3-6 and 5-10 mmHg, respectively. Blood gases at 24 hours did not differ from baseline values. The adrenaline test showed a dose dependent response, with aortic pressure increasing from 98/70 to 220/150 mmHg and heart rate from 110 to 185 beats/min. CONCLUSION: Orthotopic transplantation of porcine hearts harvested 24 hours after brain death and preserved for 24 hours can be done safely.


Assuntos
Transplante de Coração , Preservação de Órgãos/métodos , Assistência Perioperatória/métodos , Coleta de Tecidos e Órgãos/métodos , Animais , Morte Encefálica , Modelos Animais de Doenças , Transplante de Coração/efeitos adversos , Transplante de Coração/métodos , Humanos , Modelos Anatômicos , Suínos , Sobrevivência de Tecidos , Resultado do Tratamento
13.
BMC Cardiovasc Disord ; 10: 53, 2010 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-21029406

RESUMO

BACKGROUND: Optimal manual closed chest compressions are difficult to give. A mechanical compression/decompression device, named LUCAS, is programmed to give compression according to the latest international guidelines (2005) for cardiopulmonary resuscitation (CPR). The aim of the present study was to compare manual CPR with LUCAS-CPR. METHODS: 30 kg pigs were anesthetized and intubated. After a base-line period and five minutes of ventricular fibrillation, manual CPR (n = 8) or LUCAS-CPR (n = 8) was started and run for 20 minutes. Professional paramedics gave manual chest compression's alternating in 2-minute periods. Ventilation, one breath for each 10 compressions, was given to all animals. Defibrillation and, if needed, adrenaline were given to obtain a return of spontaneous circulation (ROSC). RESULTS: The mean coronary perfusion pressure was significantly (p < 0.01) higher in the mechanical group, around 20 mmHg, compared to around 5 mmHg in the manual group. In the manual group 54 rib fractures occurred compared to 33 in the LUCAS group (p < 0.01). In the manual group one severe liver injury and one pressure pneumothorax were also seen. All 8 pigs in the mechanical group achieved ROSC, as compared with 3 pigs in the manual group. CONCLUSIONS: LUCAS-CPR gave significantly higher coronary perfusion pressure and significantly fewer rib fractures than manual CPR in this porcine model.


Assuntos
Reanimação Cardiopulmonar/instrumentação , Desfibriladores/estatística & dados numéricos , Manipulações Musculoesqueléticas/efeitos adversos , Fibrilação Ventricular/terapia , Animais , Determinação da Pressão Arterial , Reanimação Cardiopulmonar/efeitos adversos , Reanimação Cardiopulmonar/métodos , Modelos Animais de Doenças , Humanos , Manipulações Musculoesqueléticas/métodos , Guias de Prática Clínica como Assunto , Recuperação de Função Fisiológica , Fraturas das Costelas/etiologia , Fraturas das Costelas/prevenção & controle , Suínos , Fibrilação Ventricular/fisiopatologia
14.
Resuscitation ; 62(2): 219-27, 2004 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-15294408

RESUMO

The aim of the present study was to compare the efficacy of intratracheal continuous insufflation of oxygen (CIO) with intermittent positive pressure ventilation (IPPV) regarding gas exchange and haemodynamics during mechanical chest compression-active decompression cardiopulmonary resuscitation (mCPR) provided by the LUCAS device. Ventricular fibrillation (VF) was induced electrically and ventilation was discontinued in 16 pigs, mean body weight 23 kg (range 22-27 kg). They were randomized into two groups (CIO versus IPPV). After 8 min of VF, mCPR was started and run for 30 min in normothermia, after which defibrillation was attempted during on-going mCPR. Return of spontaneous circulation was obtained in eight of eight CIO pigs and in four of eight IPPV pigs. Arterial oxygen tension (P < 0.05) and coronary perfusion pressure (P < 0.01) were significantly higher in the CIO pigs. Arterial CO(2)-tension was subnormal in both groups and significantly (P < 0.05) lower in the IPPV-pigs (around 4.5 versus 3.0 kPa). The intratracheal pressure differed significantly (P < 0.001) between the two groups. It was negative in each decompression phase in the IPPV pigs in spite of 6 mmHg of PEEP. The CIO pigs had a positive intratracheal pressure during the whole cycle of mCPR, with a minimum pressure of 8 mmHg during each decompression phase. To conclude, mCPR combined with CIO gave adequate ventilation and significantly better oxygenation and coronary perfusion pressure than mCPR combined with IPPV.


Assuntos
Reanimação Cardiopulmonar/métodos , Insuflação/métodos , Oxigênio/administração & dosagem , Animais , Reanimação Cardiopulmonar/instrumentação , Ventilação com Pressão Positiva Intermitente , Intubação Intratraqueal , Troca Gasosa Pulmonar , Suínos
15.
Resuscitation ; 58(3): 249-58, 2003 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-12969599

RESUMO

Outcome after prehospital defibrillation remains dire. The aim of the present study was to elucidate the pathophysiology of cardiac arrest and to suggest ways to improve outcome. Ventricular fibrillation (VF) was induced in air-ventilated pigs, after which ventilation was withdrawn. After 6.5 min of VF, ventilation with 100% oxygen was initiated. In six pigs (group I), defibrillation was the only treatment carried out. In another six pigs (group II), mechanical chest compression-decompression CPR (mCPR) was carried out for 3.5 min followed by a 40-s hands-off period before defibrillation. If unsuccessful, mCPR was resumed for a further 30 s before a second or a third, 40-s delayed, shock was given. In a final six pigs (group III) mCPR was applied for 3.5 min after which up to three shocks (if needed) were given during on-going mCPR. Return of spontaneous circulation (ROSC) occurred in none of the pigs in group I (0%), in 1 of six pigs in group II (17%) and in five of six pigs in group III (83%). During the first 3 min of VF arterial blood was transported to the venous circulation, with the consequence that the left ventricle emptied and the right ventricle became greatly distended. It took 2 min of mCPR to establish an adequate coronary perfusion pressure, which was lost when the mCPR was interrupted. During 30 s of mCPR coronary perfusion pressure was negative, but a carotid flow of about 25% of basal value was obtained. In this pig model, VF caused venous congestion, an empty left heart, and a greatly distended right heart within 3 min. Adequate heart massage before and during defibrillation greatly improved the likelihood of return of spontaneous circulation (ROSC).


Assuntos
Reanimação Cardiopulmonar/métodos , Circulação Coronária/fisiologia , Cardioversão Elétrica/métodos , Parada Cardíaca/terapia , Fibrilação Ventricular/terapia , Animais , Modelos Animais de Doenças , Parada Cardíaca/complicações , Hemodinâmica , Suínos , Fibrilação Ventricular/etiologia
16.
Resuscitation ; 55(3): 285-99, 2002 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-12458066

RESUMO

LUCAS is a new gas-driven CPR device providing automatic chest compression and active decompression. In an artificial thorax model, superior pressure and flow were obtained with LUCAS compared with manual CPR. In a randomized study on pigs with induced ventricular fibrillation significantly higher cardiac output, carotid artery blood flow, end-tidal CO(2), intrathoracic decompression-phase aortic- and coronary perfusion pressures were obtained with LUCAS-CPR (83% ROSC) compared to manual CPR (0% ROSC). In normothermic fibrillating pigs, the ROSC rate was 100% after 15 min and 38% after 60 min of LUCAS-CPR (no drug treatment). The ROSC rate increased to 75% if surface cooling to 34 degrees C was applied during the first 30 min of the 1-h resuscitation period. Experience with the first 20 patients has shown that LUCAS is light (6.5 kg), easy to handle, quick to apply (10-20 s), maintains a correct position, and works optimally during transport both on stretchers and in ambulances. In one hospital patient with a witnessed asystole where manual CPR failed, LUCAS-CPR achieved ROSC within 3 min. One year later the patient's mental capacity was fully intact. To conclude, LUCAS-CPR gives significantly better circulation during ventricular fibrillation than manual CPR.


Assuntos
Reanimação Cardiopulmonar/instrumentação , Circulação Coronária/fisiologia , Animais , Velocidade do Fluxo Sanguíneo , Gasometria , Reanimação Cardiopulmonar/métodos , Hemodinâmica , Modelos Animais , Pressão , Suínos , Tórax
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...