Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 94(3): 035106, 2023 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37012784

RESUMO

The compressed ultrafast photography (CUP) can capture non-repetitive time-evolving events at 7 × 1013 fps, which is anticipated to find a diverse range of applications in physics, biomedical imaging, and materials science. The feasibility of diagnosing ultrafast phenomenon of Z-pinch by using the CUP has been analyzed in this article. Specifically, a dual-channel CUP design has been adopted for acquiring high quality reconstructed images and the strategies of identical masks, uncorrelated masks, and complementary masks have been compared. Furthermore, the image of the first channel was rotated by 90° to balance the spatial resolution between the sweep direction and the non-sweep direction. Both five synthetic videos and two simulated Z-pinch videos were chosen as the ground truth to validate this approach. The average peak signal to noise ratio of the reconstruction results is 50.55 dB for the self-emission visible light video and 32.53 dB for the laser shadowgraph video with unrelated masks (rotated channel 1). The simulation results show that the time-space-evolving process of plasma distribution can be well retold, and the phenomenon of plasma instability can be accurately diagnosed by the dual-channel CUP with unrelated masks (rotated channel 1). This study may promote the practical applications of the CUP in the field of accelerator physics.

2.
Rev Sci Instrum ; 93(3): 033702, 2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-35365019

RESUMO

A high-speed radiation imaging system based on an image converter of liquid scintillator filled capillary arrays has been developed, which is sensitive to x rays, gamma rays, and neutrons. This imaging system has advantages of both high spatial resolution and high sensitivity because increasing the thickness of the image converter only leads to little deterioration on imaging resolution. The capillary arrays have dimensions of 150 mm diameter and 50 mm thickness, with 100 µm diameter of each capillary. The fluorescence decay time of the filled liquid scintillator based on the mixture of p-xylene and 2,5-diphenyloxazole has been evaluated to be ∼3 ns with the single photon method under the gamma ray excitation. The spatial resolution has been experimentally evaluated to be about 1.15 and 0.6 mm, under excitation of x rays and neutrons, respectively. The imaging system has been applied for diagnosing the dynamic x-ray spot generated by the rod pinch. Two frames in single shot with 15 ns temporal resolution and 20 ns inter-frame separation time have been obtained, which show the spatiotemporal distribution of the electrons bombarding the tungsten rod, indicating the ability of this imaging system in diagnosing dynamic radiation objects. In addition, the technique of capillary arrays provides a promising path for applications of advanced liquid scintillators in the field of radiation imaging.

3.
Zhonghua Bing Li Xue Za Zhi ; 49(5): 424-429, 2020 May 08.
Artigo em Chinês | MEDLINE | ID: mdl-32392924

RESUMO

Objective: To investigate the expression and significance of Nek2B and ß-catenin expression in triple negative breast cancer (TNBC) at molecule levels. Methods: By using the methods of bioinformatics [GEO2R online tool, gene ontology (GO) function analysis, KEGG biological pathway enrichment analysis], the differentially expressed genes were screened from TNBC microarray data.Expression levels of Nek2B and ß-catenin TNBC cell lines were detected by Western blot and qRT-PCR.From January 1, 2007 to December 31, 2012, eighty cases of TNBC were collected from the Second Hospital of Shanxi Medical University. The expression of Nek2B in TNBC tumor tissue was detected by immunohistochemistry and tissue microarray, and the relationship between Nek2B and clinical pathological characteristics of TNBC was analyzed. Results: Through bioinformatics analysis of the cDNA chip sets of 2 TNBC tumors(GSE38959,GSE27447), 998 differentially expressed genes were obtained in the initial screening, and 13 differentially expressed genes were revealed after intersection. The results of biological pathway analysis showed that the common differential expression genes were closely related to Wnt/ß-catenin pathway, among which Nek2 expression showed the greatest difference and was associated with poor prognosis. Expression intensity of Nek2B and repeated ß-catenin in the same TNBC cell line was consistent.The results of immunohistochemistry showed that the high expression of Nek2B was related to the high histological stage (G3;84.3% vs.37.9%, P<0.001), lymph node metastasis group (76.7% vs.54.1%, P=0.032), high Ki-67 positive index group (78.6% vs.52.6%, P=0.007) and ß-catenin positive expression group (72.5% vs.27.3%, P=0.018). Conclusions: The high level of Nek2B expression is related to a poor prognosis in TNBC patients. In TNBC tissues and cells, the expression of Nek2B is correlated with ß-catenin, suggesting that Nek2B may affect the occurrence and development of TNBC by regulating the Wnt/ß-catenin patients signaling pathway.


Assuntos
Neoplasias de Mama Triplo Negativas , Linhagem Celular Tumoral , Biologia Computacional , Humanos , Quinases Relacionadas a NIMA , Via de Sinalização Wnt , beta Catenina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...