Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 459
Filtrar
2.
Invest Ophthalmol Vis Sci ; 65(6): 23, 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38874964

RESUMO

Purpose: To explore differences in the relationship between gestational age (GA) and birth weight (BW) percentile and ocular geometry between males and females. Methods: The Gutenberg Prematurity Eye Study involved a prospective ophthalmic examination of adults, aged 18 to 52 years, who were born preterm or at term, in Germany. The associations between GA and BW percentile on the main outcome measures were evaluated by uni- and multivariable linear regression analyses. The main outcome measures were central corneal thickness, corneal radius, anterior chamber depth, lens thickness, posterior segment length, and central foveal thickness. Potential sex-specific differences and an effect modification by sex were analyzed. Results: This study involved 438 participants (245 females, 193 males) with an average age of 28.6 ± 8.7 years. In female participants, central foveal thickness was negatively associated with a higher GA (B = -2.99; P < 0.001). Similarly, male participants also demonstrated a negative association between central foveal thickness and GA (B = -4.27; P < 0.001). The multivariable model with effect modification revealed that the central foveal thickness was thicker with lower GA. There was an association between the effect modification of GA with sex and central foveal thickness, demonstrating a more pronounced effect of GA on central foveal thickness in male participants (B = 1.29; P = 0.04). Conclusions: This study identified a sex-specific correlation between lower GA and thicker central foveal thickness, suggesting differences in the developmental trajectory of this biometric parameter concerning GA. A thicker central foveal thickness might affect the visual acuity of individuals born preterm in adulthood, with a more pronounced impact in males and a potential predisposition to age-related diseases later in life. Sex did not influence the association of GA or BW percentile to other ocular geometric parameters.


Assuntos
Peso ao Nascer , Idade Gestacional , Humanos , Masculino , Feminino , Estudos Prospectivos , Adulto , Adulto Jovem , Adolescente , Pessoa de Meia-Idade , Peso ao Nascer/fisiologia , Fatores Sexuais , Recém-Nascido , Fóvea Central/diagnóstico por imagem , Córnea/anatomia & histologia , Córnea/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Câmara Anterior/diagnóstico por imagem , Câmara Anterior/anatomia & histologia , Recém-Nascido Prematuro , Cristalino/diagnóstico por imagem , Cristalino/anatomia & histologia , Alemanha , Acuidade Visual/fisiologia , Segmento Posterior do Olho/diagnóstico por imagem , Segmento Posterior do Olho/anatomia & histologia , Segmento Posterior do Olho/patologia
3.
Sci Rep ; 14(1): 13296, 2024 06 10.
Artigo em Inglês | MEDLINE | ID: mdl-38858519

RESUMO

To optimize and evaluate the accuracy of the vault-predicting formula generated from a very high-frequency digital ultrasound robotic scanner (Artemis Insight 100). The relationship between the achieved lens vault (LVa) at one month after intraocular collamer lens (ICL) implantation surgery and the predicted vault (LVp) was analyzed by a retrospective study, and an optimized formula was built up. Then, the accuracy of the optimized vault-predicting formula was evaluated in a prospective study by comparing the LVa and the predicted vault from the optimized formula (LVop). The retrospective study included 77 patients (133 eyes) while the prospective study enrolled 90 patients (170 eyes). The difference between LVp and LVa at one month after surgery was statistically significant (P < 0.05), and the linear regression analysis of LVa against LVp yielded a good fit (R2 = 0.68). The optimized vault-predicting formula was LVop (µm) = 1.21 × LVp (µm) + 124.73. In the validation study, the difference between LVop and LVa was not statistically significant (P = 0.10), and a good agreement between LVop and LVa was shown by Bland-Altman analysis. The optimized vault-predicting formula could predict the actual LV after ICL implantation surgery, help to select an appropriate ICL size and reduce the need for re-operation.


Assuntos
Implante de Lente Intraocular , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Adulto , Estudos Retrospectivos , Estudos Prospectivos , Implante de Lente Intraocular/métodos , Segmento Anterior do Olho/diagnóstico por imagem , Segmento Anterior do Olho/cirurgia , Miopia/cirurgia , Ultrassonografia/métodos , Cristalino/cirurgia , Cristalino/diagnóstico por imagem
4.
Int Ophthalmol ; 44(1): 266, 2024 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-38913255

RESUMO

PURPOSE: Subluxation of the crystalline lens (Ectopia Lentis, EL) can lead to significant visual impairment and serves as a diagnostic criterion for genetic disorders such as the Marfan syndrome. There is no established criterion to diagnose and quantify EL. We prospectively investigated the distance between the zonular fibre insertion and the limbus (ZLD) in healthy subjects as a parameter to assess the position of the lens, quantify EL and provide normative data. METHODS: This prospective, observational, cross-sectional study includes one-hundred-fifty eyes of 150 healthy participants (mean age 28 years, range 4-68). Pupils were dilated with tropicamide 0.5% and phenylephrine 2.5% eyedrops. ZLD was measured in mydriasis at the slit lamp as the distance between the most central visible insertions of the zonular fibres on the lens surface and the corneoscleral limbus. Vertical pupil diameter (PD) and refractive error were recorded. If zonular fibre insertions were not visible, the distance between limbus and the pupillary margin was recorded as ZLD. RESULTS: 145 right and 5 left eyes were examined. 93% of study subjects were Caucasian, 7% were Asian. In eyes with visible zonular fibre insertions (n = 76 eyes), ZLD was 1.30 ± 0.28 mm (mean ± SD, range 0.7-2.1) and PD was 8.79 ± 0.57 mm (7.5-9.8). In the remaining 74 eyes, ZLD was 1.38 ± 0.28 mm (0.7-2.1), and PD was 8.13 ± 0.58 mm (6.7-9.4). For all eyes, ZLD was 1.34 ± 0.29 mm (0.7-2.1), and PD was 8.47 ± 0.66 mm (6.7-9.8). Refractive error and sex did not significantly affect ZLD. Smaller PD and older age were associated with larger ZLD (P < 0.001 and P = 0.036, respectively). CONCLUSION: Average ZLD was 1.34 mm in eyes of healthy subjects. Older age correlated with larger ZLD. These normative data will aid in diagnosing and quantifying EL.


Assuntos
Ectopia do Cristalino , Cristalino , Humanos , Ectopia do Cristalino/diagnóstico , Masculino , Feminino , Estudos Prospectivos , Estudos Transversais , Adulto , Criança , Adolescente , Pessoa de Meia-Idade , Adulto Jovem , Idoso , Pré-Escolar , Cristalino/diagnóstico por imagem , Cristalino/patologia , Limbo da Córnea/patologia , Pupila/efeitos dos fármacos
5.
BMC Ophthalmol ; 24(1): 206, 2024 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-38711059

RESUMO

PURPOSE: The main objective is to quantify the lens nuclear opacity using spectral-domain optical coherence tomography (SD-OCT) and to evaluate its association with Lens Opacities Classification System III (LOCS-III) system, lens thickness (LT), and surgical parameters. The secondary objective is to assess the diagnostic model performance for hard nuclear cataract. METHODS: This study included 70 eyes of 57 adults with cataract, with 49 (70%) and 21 (30%) in training and validation cohort, respectively. Correlations of the average nuclear density (AND) /maximum nuclear density (MND) with LOCS-III scores, LT, and surgical parameters were analyzed. Univariate and multivariate logistic regression analysis, receiver operating characteristic curves and calibration curves were performed for the diagnostic of hard nuclear cataract. RESULTS: The pre-operative uncorrected distance visual acuity (UDVA), intraocular pressure (IOP), mean axial length (AL), and LT were 1.20 ± 0.47 log MAR, 15.50 ± 2.87 mmHg, 27.34 ± 3.77 mm and 4.32 ± 0.45 mm, respectively. The average nuclear opalescence (NO) and nuclear colour (NC) scores were 3.61 ± 0.94 and 3.50 ± 0.91 (ranging from 1.00 to 6.90), respectively. The average AND and MND were 137.94 ± 17.01 and 230.01 ± 8.91, respectively. NC and NO scores both significantly correlated with the AND (rNC = 0.733, p = 0.000; rNO = 0.755, p = 0.000) and MND (rNC = 0.643, p = 0.000; rNO = 0.634, p = 0.000). In the training cohort, the area under the curve (AUC) of the model was 0.769 (P < 0.001, 95%CI 0.620-0.919), which had a good degree of differentiation (Fig. 2a). The calibration curve showed good agreement between predicted and actual probability. CONCLUSION: The nuclear density measurement on SD-OCT images can serve as an objective and reliable indicator for quantifying nuclear density.


Assuntos
Catarata , Núcleo do Cristalino , Tomografia de Coerência Óptica , Acuidade Visual , Humanos , Feminino , Masculino , Tomografia de Coerência Óptica/métodos , Catarata/diagnóstico , Idoso , Pessoa de Meia-Idade , Núcleo do Cristalino/patologia , Núcleo do Cristalino/diagnóstico por imagem , Acuidade Visual/fisiologia , Curva ROC , Estudos Retrospectivos , Facoemulsificação , Idoso de 80 Anos ou mais , Adulto , Cristalino/diagnóstico por imagem , Cristalino/patologia
6.
Pediatr Radiol ; 54(7): 1197-1204, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38769141

RESUMO

BACKGROUND: Reports comparing field lens doses between helical scans with a 40-mm detector width and axial scans with a 160-mm detector width using different computed tomography (CT) scanners are currently scarce. OBJECTIVE: To compare scatter doses for lenses between a helical scan with a 40-mm detector width and an axial scan with a 160-mm detector width when using different CT scanners in the context of pediatric chest examinations. MATERIALS AND METHODS: Two different CT machines were used: Revolution CT (GE Healthcare, Waukesha, WI) with a 256-row, 0.625-mm multidetector; and Aquilion ONE GENESIS Edition (Canon Medical Systems, Otawara, Japan) with a 320-row, 0.5-mm multidetector. Three pediatric anthropomorphic phantoms were used, with optically stimulated luminescence dosimeters (OSLDs) placed on the left and right lenses. The scatter dose values measured by the OSLDs were compared between a helical scan with a 40-mm detector width and an axial scan with a 160-mm detector width during pediatric chest CT examinations. RESULTS: Median equivalent doses for the helical and axial scans were 0.12 and 0.12 mSv/mGy for the newborn, 0.17 and 0.16 mSv/mGy for the 1-year-old, and 0.18 and 0.15 mSv/mGy for the 5-year-old, respectively, when using the Revolution CT. With the Revolution CT, no significant differences were observed in the scatter doses between helical and axial scans in the newborn and 1-year-old phantoms. However, the lens scatter dose for the helical scan was approximately 20-35% higher than that for the axial scan in the 5-year-old phantom (P<0.01). The median equivalent doses of eye lenses for the helical and axial scans were 0.12 and 0.07 mSv/mGy for the newborn, 0.07 and 0.05 mSv/mGy for the 1-year-old, and 0.14 and 0.12 mSv/mGy for the 5-year-old, respectively, when using the Aquilion ONE. With the Aquilion ONE, lens scatter doses for the helical scan were approximately 70%, 40%, and 30% higher in the newborn, 1-year-old, and 5-year-old phantoms, respectively, than those for the axial scan (P<0.01). CONCLUSIONS: When using the Aquilion ONE, lens scatter doses for the helical scan were significantly higher in all three phantoms than those for the axial scan. In contrast, when using the Revolution CT, the lens scatter dose for the helical scan was significantly higher in the 5-year-old phantom than that for the axial scan. These results suggest that although scattered doses may vary with respect to the CT scanner and body size, they are generally lower in the case of axial scans.


Assuntos
Cristalino , Doses de Radiação , Espalhamento de Radiação , Tomografia Computadorizada por Raios X , Humanos , Masculino , Feminino , Cristalino/diagnóstico por imagem , Cristalino/efeitos da radiação , Tomografia Computadorizada Espiral/métodos , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas , Radiometria , Exposição à Radiação , Recém-Nascido , Lactente , Pré-Escolar
7.
Ophthalmic Physiol Opt ; 44(5): 1041-1051, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38676399

RESUMO

PURPOSE: This study compared in vivo crystalline lens shape measurements using B-scan images from the IOLMaster 700 with phakometry. METHODS: Twenty-four young adult participants underwent IOLMaster 700 and phakometry measurements under cycloplegia (1% cyclopentolate). The IOLMaster 700 generated B-scan images along six meridians in 30° increments, which were analysed using custom MATLAB software to determine lens surface radii of curvature. Phakometry measurements were obtained using Purkinje images reflected from the lens surfaces. RESULTS: The IOLMaster 700 image analysis method yielded a lower mean anterior lens surface spherical equivalent power (+6.20 D) than phakometry (+7.55 D); however, the two measurements were strongly correlated (R(21) = 0.97, p < 0.0001). The astigmatic power vectors (J0 and J45) for the anterior lens surface were significantly higher for the IOLMaster 700 measurements, with only J0 showing a significant moderate positive correlation (R(21) = 0.57, p = 0.005). For the posterior lens surface, the IOLMaster 700 measurements had a higher mean spherical power (+14.28 D) compared to phakometry (+13.70 D); however, a strong positive correlation (R(21) = 0.90, p < 0.0001) was observed. No significant correlations were noted for posterior lens surface astigmatic vectors (J0 and J45). The IOLMaster 700 estimates for the equivalent lens mean spherical power were slightly lower than those for phakometry, with a mean difference of -0.72 D, and both methods were positively correlated (R(21) = 0.94, p < 0.0001). CONCLUSIONS: The findings demonstrate that IOLMaster 700 B-scan image analysis technique provides similar estimates of lens surface powers to phakometry. These results highlight the potential of the IOLMaster 700 to provide measurements of lens shape, informing future research and clinical use.


Assuntos
Cristalino , Humanos , Cristalino/diagnóstico por imagem , Cristalino/anatomia & histologia , Feminino , Masculino , Adulto , Adulto Jovem , Refração Ocular/fisiologia , Biometria/métodos
8.
BMC Ophthalmol ; 24(1): 203, 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38684941

RESUMO

BACKGROUND: This study aims to investigate the morphologic features of the crystalline lens in Primary Angle Closure Disease (PACD) patients with zonular instability during cataract surgery using the swept-source CASIA 2 Anterior Segment-Optical Coherence Tomography (AS-OCT) system. METHODS: A total of 398 eyes (125 PACD eyes with zonular instability, 133 PACD eyes with zonular stability, and 140 cataract patient controls) of 398 patients who underwent cataract surgery combined or not glaucoma surgery between January 2021 and January 2023 were enrolled. The crystalline lens parameters were measured by CASIA2 AS-OCT. Then, logistic regression was performed to evaluate the risk factors associated with zonular instability. RESULTS: The results revealed that PACD eyes had a more anterior lens equator position, a steeper anterior curvature of lens, shorter Axial Length (AL), shallower Anterior Chamber Distance (ACD), higher Lens Vault (LV) and thicker Lens Thickness (LT), when compared to eyes in the cataract control group. Furthermore, PACD eyes in the zonular instability group had steeper front R, front Rs and Front Rf, flatter back Rf, thicker lens anterior part thickness, higher lens anterior-to-posterior part thickness ratios, shallower ACD, and greater LV, when compared to PACD eyes with zonular stability. The logistic regression analysis, which was adjusted for age and gender, revealed that zonular instability was positively correlated with anterior part thickness, lens anterior-to-posterior part thickness ratio, and LV, but was negatively correlated with lens anterior radius and ACD. CONCLUSION: Steeper anterior curvature, increased lens anterior part thickness, higher anterior-to-posterior part thickness ratio, shallower ACD, and greater LV are the anatomic features of PACD eyes associated with zonular instability.


Assuntos
Segmento Anterior do Olho , Glaucoma de Ângulo Fechado , Cristalino , Tomografia de Coerência Óptica , Humanos , Tomografia de Coerência Óptica/métodos , Glaucoma de Ângulo Fechado/fisiopatologia , Glaucoma de Ângulo Fechado/diagnóstico , Feminino , Masculino , Idoso , Pessoa de Meia-Idade , Segmento Anterior do Olho/diagnóstico por imagem , Segmento Anterior do Olho/patologia , Cristalino/diagnóstico por imagem , Cristalino/patologia , Estudos Retrospectivos , Pressão Intraocular/fisiologia , Acuidade Visual/fisiologia
9.
BMJ Open Ophthalmol ; 9(1)2024 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-38684375

RESUMO

BACKGROUND: Retinal imaging, including fundus autofluorescence (FAF), strongly depends on the clearness of the optical media. Lens status is crucial since the ageing lens has both light-blocking and autofluorescence (AF) properties that distort image analysis. Here, we report both lens opacification and AF metrics and the effect on automated image quality assessment. METHODS: 227 subjects (range: 19-89 years old) received quantitative AF of the lens (LQAF), Scheimpflug, anterior chamber optical coherence tomography as well as blue/green FAF (BAF/GAF), and infrared (IR) imaging. LQAF values, the Pentacam Nucleus Staging score and the relative lens reflectivity were extracted to estimate lens opacification. Mean opinion scores of FAF and IR image quality were compiled by medical readers. A regression model for predicting image quality was developed using a convolutional neural network (CNN). Correlation analysis was conducted to assess the association of lens scores, with retinal image quality derived from human or CNN annotations. RESULTS: Retinal image quality was generally high across all imaging modalities (IR (8.25±1.99) >GAF >BAF (6.6±3.13)). CNN image quality prediction was excellent (average mean absolute error (MAE) 0.9). Predictions were comparable to human grading. Overall, LQAF showed the highest correlation with image quality grading criteria for all imaging modalities (eg, Pearson correlation±CI -0.35 (-0.50 to 0.18) for BAF/LQAF). BAF image quality was most vulnerable to an increase in lenticular metrics, while IR (-0.19 (-0.38 to 0.01)) demonstrated the highest resilience. CONCLUSION: The use of CNN-based retinal image quality assessment achieved excellent results. The study highlights the vulnerability of BAF to lenticular remodelling. These results can aid in the development of cut-off values for clinical studies, ensuring reliable data collection for the monitoring of retinal diseases.


Assuntos
Catarata , Tomografia de Coerência Óptica , Humanos , Idoso , Pessoa de Meia-Idade , Adulto , Idoso de 80 Anos ou mais , Feminino , Masculino , Tomografia de Coerência Óptica/métodos , Adulto Jovem , Catarata/diagnóstico por imagem , Catarata/patologia , Retina/diagnóstico por imagem , Retina/patologia , Imagem Óptica/métodos , Cristalino/diagnóstico por imagem , Cristalino/patologia , Angiofluoresceinografia/métodos
10.
Exp Eye Res ; 243: 109914, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38685338

RESUMO

A-scan ultrasonography enables precise measurement of internal ocular structures. Historically, its use has underpinned fundamental studies of eye development and aberrant eye growth in animal models of myopia; however, the procedure typically requires anaesthesia. Since anaesthesia affects intra-ocular pressure (IOP), we investigated changes in internal ocular structures with isoflurane exposure and compared measurements with those taken in awake animals using optical coherence tomography (OCT). Continuous A-scan ultrasonography was undertaken in tri-coloured guinea pigs aged 21 (n = 5), 90 (n = 5) or 160 (n = 5) days while anaesthetised (up to 36 min) with isoflurane (5% in 1.5L/min O2). Peaks were selected from ultrasound traces corresponding to the boundaries of the cornea, crystalline lens, retina, choroid and sclera. OCT scans (Zeiss Cirrus Photo 800) of the posterior eye layers were taken in 28-day-old animals (n = 19) and compared with ultrasound traces, with choroid and scleral thickness adjusted for the duration of anaesthesia based on the changes modelled in 21-day-old animals. Ultrasound traces recorded sequentially in left and right eyes in 14-day-old animals (n = 30) were compared, with each adjusted for anaesthesia duration. The thickness of the cornea was measured in enucleated eyes (n = 5) using OCT following the application of ultrasound gel (up to 20 min). Retinal thickness was the only ultrasound internal measure unaffected by anaesthesia. All other internal distances rapidly changed and were well fitted by exponential functions (either rise-to-max or decay). After 10 and 20 min of anaesthesia, the thickness of the cornea, crystalline lens and sclera increased by 17.1% and 23.3%, 0.4% and 0.6%, and 5.2% and 6.5% respectively, whilst the anterior chamber, vitreous chamber and choroid decreased by 4.4% and 6.1%, 0.7% and 1.1%, and 10.7% and 11.8% respectively. In enucleated eyes, prolonged contact of the cornea with ultrasound gel resulted in an increase in thickness of 9.3% after 10 min, accounting for approximately half of the expansion observed in live animals. At the back of the eye, ultrasound measurements of the thickness of the retina, choroid and sclera were highly correlated with those from posterior segment OCT images (R2 = 0.92, p = 1.2 × 10-13, R2 = 0.55, p = 4.0 × 10-4, R2 = 0.72, p = 5.0 × 10-6 respectively). Furthermore, ultrasound measures for all ocular components were highly correlated in left and right eyes measured sequentially, when each was adjusted for anaesthetic depth. This study shows that the depth of ocular components can change dramatically with anaesthesia. Researchers should therefore be wary of these concomitant effects and should employ adjustments to better render 'true' values.


Assuntos
Anestésicos Inalatórios , Isoflurano , Tomografia de Coerência Óptica , Ultrassonografia , Animais , Tomografia de Coerência Óptica/métodos , Cobaias , Isoflurano/farmacologia , Anestésicos Inalatórios/farmacologia , Corioide/efeitos dos fármacos , Corioide/diagnóstico por imagem , Envelhecimento/fisiologia , Pressão Intraocular/efeitos dos fármacos , Pressão Intraocular/fisiologia , Córnea/efeitos dos fármacos , Córnea/diagnóstico por imagem , Retina/efeitos dos fármacos , Retina/diagnóstico por imagem , Esclera/efeitos dos fármacos , Esclera/diagnóstico por imagem , Fatores de Tempo , Olho/diagnóstico por imagem , Olho/efeitos dos fármacos , Modelos Animais de Doenças , Cristalino/diagnóstico por imagem , Cristalino/efeitos dos fármacos
11.
Int Ophthalmol ; 44(1): 194, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38656707

RESUMO

PURPOSE: To evaluate the magnitude of IOL transversal shift (ITS) after phacoemulsification and to analyse the factors contributing to IOL decentration and ITS. METHODS: 94 consecutive patients who underwent cataract surgery and IOL implantation was enrolled. Each patient underwent anterior segment optical coherence tomography with CASIA 2 (Tomey, Nagoya, Japan) to assess crystalline lens decentration, thickness and diameter seven days preoperatively and at one and sixty days postoperatively. Univariate and multivariate linear regression analysis were performed to evaluate the determinants of ITS and final decentration. RESULTS: The preoperative crystalline lens diameter was associated with the ITS and with the IOL final decentration. A positive association between the final IOL decentration and the first post-surgical day decentration was found (p < 0.0001). CONCLUSION: Greater crystalline lens diameter was associated with greater decentration and with greater ITS. Day-one IOL decentration seems to be the main determinant of final IOL decentration.


Assuntos
Segmento Anterior do Olho , Facoemulsificação , Tomografia de Coerência Óptica , Humanos , Facoemulsificação/efeitos adversos , Tomografia de Coerência Óptica/métodos , Masculino , Feminino , Idoso , Segmento Anterior do Olho/diagnóstico por imagem , Lentes Intraoculares/efeitos adversos , Pessoa de Meia-Idade , Acuidade Visual , Idoso de 80 Anos ou mais , Migração do Implante de Lente Intraocular/diagnóstico , Migração do Implante de Lente Intraocular/etiologia , Implante de Lente Intraocular/efeitos adversos , Complicações Pós-Operatórias/diagnóstico , Cristalino/diagnóstico por imagem , Estudos Prospectivos
12.
Graefes Arch Clin Exp Ophthalmol ; 262(8): 2515-2523, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38427049

RESUMO

PURPOSE: To investigate the characteristics and associations of anterior lens zonules lengths in cataract patients via ultrasound biomicroscope (UBM) measurement. METHODS: Patients with age-related cataracts and high myopic cataracts who planned to undergo cataract surgery were included in the study. After routine ophthalmic examinations, the UBM was performed on both eyes to get images of the anterior lens zonules, and Image J software was used to measure the lengths of the lens zonules. Axial length (AL), anterior chamber depth (ACD), lens thickness (LT), and white-to-white (WTW) diameter of both eyes were obtained by IOL Master 700. Univariate and multivariate regression analyses were used to assess associated factors of anterior lens zonules lengths. RESULTS: Forty-nine patients with age-related cataracts and 33 patients with high myopic cataracts were enrolled. High myopic cataract patients were younger and had longer anterior lens zonules. Multivariate regression analysis showed that anterior lens zonules lengths were associated with axial lengths (temporal location: ß = 0.036, P = 0.029; nasal location: ß = 0.034, P = 0.011; superior location: ß = 0.046, P = 0.002) and ACD (inferior location: ß = 0.305, P = 0.016) in right eyes. In left eyes, anterior lens zonules lengths were associated with axial lengths (temporal location: ß = 0.028, P = 0.017; inferior location: ß = 0.026, P = 0.016; nasal location: ß = 0.033, P < 0.001) and ACD (inferior location: ß = 0.215, P = 0.030; superior location: ß = 0.290, P = 0.011). CONCLUSIONS: High myopic cataract patients have longer anterior lens zonules. AL and ACD contributed to the lengths of anterior lens zonules. Thus, for patients with long AL and deeper ACD, lens zonules measurement was crucial. CLINICAL TRIAL REGISTRATION: www.chictr.org.cn identifier is ChiCTR2300071397.


Assuntos
Comprimento Axial do Olho , Catarata , Microscopia Acústica , Humanos , Feminino , Masculino , Catarata/complicações , Catarata/diagnóstico , Idoso , Pessoa de Meia-Idade , Comprimento Axial do Olho/patologia , Comprimento Axial do Olho/diagnóstico por imagem , Câmara Anterior/diagnóstico por imagem , Câmara Anterior/patologia , Cristalino/diagnóstico por imagem , Idoso de 80 Anos ou mais , Biometria
14.
Invest Ophthalmol Vis Sci ; 65(3): 13, 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38466288

RESUMO

Purpose: Quantitative fundus autofluorescence (QAF) currently deploys an age-based score to correct for lens opacification. However, in elderly people, lens opacification varies strongly between individuals of similar age, and innate lens autofluorescence is not included in the current correction formula. Our goal was to develop and compare an individualized formula. Methods: One hundred thirty participants were examined cross-sectionally, and a subset of 30 participants received additional multimodal imaging 2-week post-cataract-surgery. Imaging included the Scheimpflug principle, anterior chamber optical coherence tomography (AC-OCT), lens quantitative autofluorescence (LQAF), and retinal QAF imaging. Among the subset, least absolute shrinkage and selection operator regression and backward selection was implemented to determine which lens score best predicts the QAF value after lens extraction. Subsequently, a spline mixed model was applied to the whole cohort to quantify the influence of LQAF and Scheimpflug on QAF. Results: Age and LQAF measurements were found to be the most relevant variables, whereas AC-OCT measurements and Scheimpflug were eliminated by backward selection. Both an increase in Scheimpflug and LQAF values were associated with a decrease in QAF. The prediction error of the spline model (mean absolute error [MAE] ± standard deviation) of 32.2 ± 23.4 (QAF a.u.) was markedly lower compared to the current age-based formula MAE of 96.1 ± 93.5. Both smooth terms, LQAF (P < 0.01) and Scheimpflug (P < 0.001), were significant for the spline mixed model. Conclusions: LQAF imaging proved to be the most predictive for the impact of the natural lens on QAF imaging. The application of lens scores in the clinic could improve the accuracy of QAF imaging interpretation and might allow including aged patients in future QAF studies.


Assuntos
Extração de Catarata , Catarata , Cristalino , Idoso , Humanos , Cristalino/diagnóstico por imagem , Fundo de Olho , Retina
15.
Vestn Oftalmol ; 140(1): 11-18, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38450461

RESUMO

Analysis of lens changes in Marfan syndrome (MS), in addition to assessing the position of the lens itself, should include the possibility of examining its supporting and accommodative components (ciliary zonule and ciliary body), or what can be called the entire anatomical complex of the lens. Optical methods of studying the structures of the anterior segment of the eye, due to iris opacity, allow only to analyze the state of the lens within the natural or medically enlarged pupil width. Visualization of the structures located behind the iris is possible with the use of radiation diagnostic methods, in particular ultrasound biomicroscopy (UBM). PURPOSE: This study assesses the state of the anatomical complex of the lens in MS using UBM. MATERIAL AND METHODS: The study was carried out on clinical material previously used by us to analyze changes in the fibrous membrane of the eye in MS. At the first stage, the main (19 patients with MS, 38 eyes) and the control (24 patients with myopia, 48 eyes) groups were formed for comparative evaluation. The formed groups were standardized according to the age of the patients and the axial length of the eye. At the second stage, patients with MS were divided into subgroups depending on the absence or presence of biomicroscopic signs of ectopia lentis (22 and 16 eyes, respectively). For UBM, an ultrasound linear sensor with a scanning frequency of 50 MHz was used (Aviso device, Quantel Medical, France). Various biometric UBM indicators were determined: lens thickness, diameter of the lens, lens-axial length factor, iris-lens angle, iris-lens contact distance, posterior chamber depth, length of the fibers of ciliary zonule, thickness of the ciliary body, sclera-ciliary process angle. RESULTS: There are changes in the anatomical complex of the lens as a whole in MS (in the lens itself, the ciliary zonule, and the ciliary body), which are characterized by an increase in lens thickness and a decrease in the diameter of the lens, an increase in the length of the fibers of the ciliary zonule and a decrease in the thickness of the ciliary body. At the same time, the displacement of the lens detected by optical biomicroscopy (ectopia lentis) can be considered as an advanced stage of changes in the anatomical complex of the lens. CONCLUSION: UBM provides the possibility of full-fledged visualization of all components of the anatomical complex of the lens in terms of both diagnostics, and monitoring of changes in MS. The question of the advisability of including this method in the algorithm for diagnosing ocular manifestations in order to verify the MS remains open. Possible obstacles may be, on the one hand, related to the need for special and expensive equipment, and on the other hand, the absence of a generally accepted «normal¼ values of UBM indicators of the anatomical complex of the lens.


Assuntos
Ectopia do Cristalino , Cristalino , Lentes , Síndrome de Marfan , Humanos , Ectopia do Cristalino/diagnóstico , Ectopia do Cristalino/etiologia , Síndrome de Marfan/complicações , Síndrome de Marfan/diagnóstico , Cristalino/diagnóstico por imagem , Iris
16.
Curr Eye Res ; 49(6): 605-614, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38363071

RESUMO

PURPOSE: To investigate the influence of lens thickness (LT) on accuracy of Kane, Hill-RBF 3.0 Barrett Universal II (BUII), Emmetropia Verifying Optical (EVO), and Pearl-DGS formulas in eyes with different axial lengths (AL). METHODS: The prospective cohort study was conducted at Eye and ENT Hospital of Fudan University. Patients who had uneventful cataract surgery between March 2021 and July 2023 were recruited. Manifest refraction was conducted two-month post-surgery. Eyes were divided into 4 groups based on AL: short (<22mm), medium (22-24.5 mm), medium long (24.5-26mm) and very long (≥26mm). In each AL group, eyes were then divided into 3 subgroups based on the LT measured with IOLmaster700: thin (<4.5 mm), medium (4.5-5.0 mm), and thick (≥ 5 mm). The influence of LT on accuracy of Kane, Hill-RBF 3.0, BUII, EVO, and Pearl-DGS formulas were investigated in each AL group. RESULTS: A total of 327 eyes from 327 patients were analyzed, with 64, 102, 73 and 88 eyes in each AL group, respectively. In eyes with AL < 24.5 mm, myopic PE was significantly associated with greater LT using all the 5 formulas (all p < 0.05). Backward stepwise multivariate regression analyses revealed that LT was an important influencing factor for PE in all 5 formulas, particularly in eyes with AL <24.5 mm. In eyes with AL <24.5 mm and LT > 5.0 mm, PE of all 5 formulas calculated with the optional parameter LT were more myopic than those calculated without LT. CONCLUSIONS: Thicker LT was associated with more myopic PE among eyes with AL <24.5 mm when using all 5 formulas. Further optimization of current formulas is necessary, especially for eyes with short AL and thick LT.


Assuntos
Comprimento Axial do Olho , Biometria , Emetropia , Cristalino , Miopia Degenerativa , Refração Ocular , Humanos , Estudos Prospectivos , Masculino , Feminino , Refração Ocular/fisiologia , Comprimento Axial do Olho/patologia , Emetropia/fisiologia , Biometria/métodos , Pessoa de Meia-Idade , Cristalino/patologia , Cristalino/diagnóstico por imagem , Idoso , Miopia Degenerativa/diagnóstico , Miopia Degenerativa/fisiopatologia , Acuidade Visual , Óptica e Fotônica , Lentes Intraoculares , Implante de Lente Intraocular , Reprodutibilidade dos Testes , Miopia/fisiopatologia , Miopia/diagnóstico
17.
Curr Eye Res ; 49(6): 671-681, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38379315

RESUMO

PURPOSE: Accommodation mainly affects the lens, a structure of the eyeball that degrades with age. The aim of this work was to study the morphological changes of different ocular structures during accommodation, both in the anterior pole and the posterior pole, which may also be involved in the accommodation process. METHODS: The study will be carried out by stimulating accommodation through lenses of -1.00, -3.00 and -5.00 D starting from the spherical equivalent (M) of each participant in different age groups, from 18 to 66 years. To obtain the M value, aberrometry was achieved, and retinal optical coherence tomography and anterior pole tomography were performed to evaluate the possible structural modifications (central and peripheral), while accommodation was progressively stimulated. RESULTS: It showed that as the accommodative demand increased, morphological changes were produced in retinal thickness, both in the central and peripheral retina, in all age groups. A thinning of the retina was observed in the central 3 mm, while significant progressive thickening was observed closer to the periphery (up to 6 mm from the fovea) as the required accommodative power increased. A decrease in the anterior chamber depth (ACD) and anterior chamber volume (ACV) was observed with increasing lens power. CONCLUSION: Structural changes were observed in the central and peripheral retina, as well as in the ACD and ACV, while progressively greater accommodation was stimulated, showing that these structures were modified in the accommodation process even in advanced presbyopes.


Assuntos
Acomodação Ocular , Envelhecimento , Câmara Anterior , Retina , Tomografia de Coerência Óptica , Humanos , Acomodação Ocular/fisiologia , Tomografia de Coerência Óptica/métodos , Adulto , Pessoa de Meia-Idade , Idoso , Adulto Jovem , Câmara Anterior/diagnóstico por imagem , Retina/diagnóstico por imagem , Masculino , Adolescente , Envelhecimento/fisiologia , Feminino , Cristalino/diagnóstico por imagem , Cristalino/fisiologia , Cristalino/anatomia & histologia , Refração Ocular/fisiologia
18.
Pediatr Radiol ; 54(5): 758-763, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38308740

RESUMO

BACKGROUND: Adaptive collimation reduces the dose deposited outside the imaged volume along the z-axis. An increase in the dose deposited outside the imaged volume (to the lens and thyroid) in the z-axis direction is a concern in paediatric computed tomography (CT). OBJECTIVE: To compare the dose deposited outside the imaged volume (to the lens and thyroid) between 40-mm and 80-mm collimation during thoracic paediatric helical CT. MATERIALS AND METHODS: We used anthropomorphic phantoms of newborns and 5-year-olds with 40-mm and 80-mm collimation during helical CT. We compared the measured dose deposited outside the imaged volume using optically stimulated luminescence dosimeters (OSLD) at the surfaces of the lens and thyroid and the image noise between the 40-mm and 80-mm collimations. RESULTS: There were significant differences in the dose deposited outside the imaged volume (to the lens and thyroid) between the 40-mm and 80-mm collimations for both phantoms (P < 0.01). CONCLUSION: Compared with that observed for 80-mm collimation in helical CT scans of the paediatric thorax, the dose deposited outside the imaged volume (to the lens and thyroid) was significantly lower in newborns and 5-year-olds with 40-mm collimation.


Assuntos
Cristalino , Imagens de Fantasmas , Doses de Radiação , Radiografia Torácica , Glândula Tireoide , Humanos , Glândula Tireoide/diagnóstico por imagem , Recém-Nascido , Cristalino/diagnóstico por imagem , Cristalino/efeitos da radiação , Radiografia Torácica/métodos , Radiografia Torácica/instrumentação , Pré-Escolar , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada Espiral/métodos
19.
Int Ophthalmol ; 44(1): 34, 2024 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-38332205

RESUMO

PURPOSE: To explore the associations between central anterior chamber depth (CACD) and other anterior segment biometric parameters and to determine the possible determinants of CACD in short, normal, and long eyes. METHODS: The biometric data of pre-operation patients aged 50-80 years with coexisting cataract and primary angle-closure disease or senile cataract were reviewed. Axial length (AL), CACD, lens thickness (LT), central corneal thickness (CCT), and white-to-white distance (WTW) were measured by Lenstar optical biometry (Lenstar 900). The data of 100 normal eyes (AL = 22 to 26 mm), 100 short eyes (AL ≤ 22 mm), and 100 long eyes (AL ≥ 26 mm) were consecutively collected for subsequent analyses. RESULTS: The mean age of the subjects was 66.60 ± 7.85 years, with 25.7% of the sample being men. Both CACD and WTW were found to be smallest in short eyes and were smaller in normal eyes than in long eyes (F = 126.524, P < 0.001; F = 28.458, P < 0.001). The mean LT was significantly thicker in short eyes than in normal and long eyes (4.66 mm versus 4.49 mm versus 4.40 mm; F = 18.099, P < 0.001). No significant differences were observed in CCT between the three AL groups (F = 2.135, P = 0.120). Stepwise regression analysis highlighted AL, LT, and WTW as three independent factors associated with CACD in the normal AL group. In the short AL group and long AL group, LT and WTW were independent factors associated with CACD. CONCLUSIONS: CACD increases as AL elongates and reaches a peak when AL exceeds 26 mm. Furthermore, CACD showed inverse correlation with LT and positive correlation with WTW. A relatively small WTW results in an anteriorly positioned lens, and thus, a decrease in CACD.


Assuntos
Catarata , Cristalino , Lentes Intraoculares , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Feminino , Cristalino/diagnóstico por imagem , Catarata/complicações , Catarata/diagnóstico , Biometria/métodos , Câmara Anterior/diagnóstico por imagem , Comprimento Axial do Olho
20.
Radiat Prot Dosimetry ; 200(4): 417-422, 2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38195763

RESUMO

This case report investigates the radiation dose received by a paediatric patient with a ventricular assist device who underwent four non-contrast brain computed tomography (CT) scans, two brain perfusion CT scans and two head angiographic CT scans. The total estimated absorbed dose to the lens of the eye is above the 500 mGy radiation-induced cataract threshold. It is recommended that this patient and those with similar imaging histories have routine follow-up with an ophthalmologist. It is also recommended that radiation dose tracking and an electronic medical alert program be implemented to allow the identification of patients who may exceed tissue reaction thresholds.


Assuntos
Catarata , Cristalino , Humanos , Criança , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Catarata/diagnóstico por imagem , Catarata/etiologia , Cabeça , Cristalino/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...