Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 18 de 18
Filter
Add more filters








Publication year range
1.
Adv Sci (Weinh) ; : e2406228, 2024 Jul 04.
Article in English | MEDLINE | ID: mdl-38962907

ABSTRACT

The transition metal-catalyzed multi-component cross-electrophile sulfonylation, which incorporates SO2 as a linker within organic frameworks, has proven to be a powerful, efficient, and cost-effective means of synthesizing challenging alkyl-alkyl sulfones. Transition metal catalysts play a crucial role in this method by transferring electrons from reductants to electrophilic organohalides, thereby causing undesirable side reactions such as homocoupling, protodehalogenation, ß-hydride elimination, etc. It is worth noting that tertiary alkyl halides have rarely been demonstrated to be compatible with current methods owing to various undesired side reactions. In this work, a zinc-promoted cross-electrophile sulfonylation is developed through a radical-polar crossover pathway. This approach enables the synthesis of various alkyl-alkyl sulfones, including 1°-1°, 2°-1°, 3°-1°, 2°-2°, and 3°-2° types, from inexpensive and readily available alkyl halides. Various functional groups are well tolerated in the work, resulting in yields of up to 93%. Additionally, this protocol has been successfully applied to intramolecular sulfonylation and homo-sulfonylation reactions. The insights gained from this work shall be useful for the further development of cross-electrophile sulfonylation to access alkyl-alkyl sulfones.

2.
Appl Opt ; 62(16): E103-E108, 2023 Jun 01.
Article in English | MEDLINE | ID: mdl-37706899

ABSTRACT

A novel fiber laser structure, to the best of our knowledge, based on an erbium-doped fiber ring (EDFR) and a silica microbottle resonator (MBR) is proposed and investigated experimentally. Two fiber laser samples based on MBRs with different geometries and diameters of 200 and 150 µm are fabricated, and their performance is studied experimentally. Periodic whispering gallery mode spectra of the MBRs are dependent on the position of the fiber taper used for coupling of light into the MBR, and this dependence is explored to achieve lasing at different wavelengths by moving the light coupling point along the axis of the microbottle incorporated into the proposed EDFR-MBR system. The influences of the pump laser power and light polarization on the system performance and laser stability are also investigated. Single-mode lasing with a maximum optical signal-to-noise ratio of 32 dB is demonstrated.

3.
Foods ; 12(13)2023 Jun 21.
Article in English | MEDLINE | ID: mdl-37444178

ABSTRACT

Different constituents of the cultivation substrate have significant effect on the yield and quality of edible mushrooms. The residue after the extraction of instant tea has exhibited to be biologically significant, and could be used as a substrate for cultivation. This study aimed to investigate the feasibility of tea extraction residue (TER) on button mushroom (Agaricus bisporus) cultivation, as an ingredient in the substrate, and assess the growth status, nutritional values, and sensory characteristics of fruiting body. The results showed that the strains could grow well on the cultivated substrate with 20% addition of TER. The total amount of hydrolyzed amino acids in the fruiting bodies of three TER-based groups (TER accounted for 10%, 20%, and 37.5%, respectively) was higher than that of the control group, and the total amount of essential amino acids was increased by 33.33%, 22.47%, and 9.92% compared with the control group, respectively. In addition, the results of gas chromatography-mass spectrometry (GC-MS) revealed that the addition of TER to the cultivation of substrate significantly enhanced the content of typical mushroom-flavor compounds in button mushroom, such as 1-octen-3-ol, 3-octanol, and 1-octen-3-one. It can be concluded that TER may be an ideal choice for the substrate in commercial cultivation of button mushroom.

4.
Chem Commun (Camb) ; 59(45): 6889-6892, 2023 Jun 01.
Article in English | MEDLINE | ID: mdl-37198944

ABSTRACT

We describe a nickel-catalyzed three-component sulfonylation of readily available non-activated alkyl chlorides. A wide range of alkyl aryl sulfones can be synthesized from alkyl chlorides, aryl boronic acids, and potassium metabisulfite, a cheap, efficient, and commercially available SO2 source under simple and easy-to-handle reaction conditions. High selectivity can be achieved with a slight excess of phenylboronic acid and a sulfur dioxide source.

5.
Sensors (Basel) ; 22(21)2022 Oct 29.
Article in English | MEDLINE | ID: mdl-36366010

ABSTRACT

A novel micron-range displacement sensor based on a whispering-gallery mode (WGM) microcapillary resonator filled with a nematic liquid crystal (LC) and a magnetic nanoparticle- coated fiber half-taper is proposed and experimentally demonstrated. In the proposed device, the tip of a fiber half-taper coated with a thin layer of magnetic nanoparticles (MNPs) moves inside the LC-filled microcapillary resonator along its axis. The input end of the fiber half-taper is connected to a pump laser source and due to the thermo-optic effect within the MNPs, the fiber tip acts as point heat source increasing the temperature of the LC material in its vicinity. An increase in the LC temperature leads to a decrease in its effective refractive index, which in turn causes spectral shift of the WGM resonances monitored in the transmission spectrum of the coupling fiber. The spectral shift of the WGMs is proportional to the displacement of the MNP-coated tip with respect to the microcapillary's light coupling point. The sensor's operation is simulated considering heat transfer in the microcapillary filled with a LC material having a negative thermo-optic coefficient. The simulations are in a good agreement with the WGMs spectral shift observed experimentally. A sensitivity to displacement of 15.44 pm/µm and a response time of 260 ms were demonstrated for the proposed sensor. The device also shows good reversibility and repeatability of response. The proposed micro-displacement sensor has potential applications in micro-manufacturing, precision measurement and medical instruments.

6.
Molecules ; 27(15)2022 Aug 03.
Article in English | MEDLINE | ID: mdl-35956884

ABSTRACT

Sufu, a Chinese traditional fermented soybean product, has a characteristic foul smell but a pleasant taste. We determined the core functional microbiota and their metabolic mechanisms during sufu fermentation by examining relationships among bacteria, characteristic flavor compounds, and physicochemical factors. Flavor compounds in sufu were detected through headspace solid-phase microextraction coupled with gas chromatography-mass spectrometry, and the microbial community structure was determined through high-throughput 16S rRNA sequencing. The results showed that the fermentation process of sufu could be divided into early and late stages. The early stage was critical for flavor development. Seven microbiota were screened based on their abundance, microbial relevance, and flavor production capacity. Five microbes were screened in the early stage: Pseudomonas, Tetragenococcus, Lysinibacillus, Pantoea, and Burkholderia-Caballeronia-Paraburkholderia. Three microbes were screened in the late stage: Exiguobacterium, Bacillus, and Pseudomonas. Their metabolic profiles were predicted. The results provided a reference for the selection of enriched bacterial genera in the fermentation process and controlling applicable process conditions to improve the flavor of sufu.


Subject(s)
Microbiota , Bacteria/metabolism , Fermentation , Microbiota/genetics , RNA, Ribosomal, 16S/genetics , RNA, Ribosomal, 16S/metabolism , Taste
7.
Microsyst Nanoeng ; 8: 63, 2022.
Article in English | MEDLINE | ID: mdl-35711674

ABSTRACT

Eye blinking is closely related to human physiology and psychology. It is an effective method of communication among people and can be used in human-machine interactions. Existing blink monitoring methods include video-oculography, electro-oculograms and infrared oculography. However, these methods suffer from uncomfortable use, safety risks, limited reliability in strong light or dark environments, and infringed informational security. In this paper, we propose an ultrasound-based portable approach for eye-blinking activity monitoring. Low-power pulse-echo ultrasound featuring biosafety is transmitted and received by microelectromechanical system (MEMS) ultrasonic transducers seamlessly integrated on glasses. The size, weight and power consumption of the transducers are 2.5 mm by 2.5 mm, 23.3 mg and 71 µW, respectively, which provides better portability than conventional methods using wearable devices. Eye-blinking activities were characterized by open and closed eye states and validated by experiments on different volunteers. Finally, real-time eye-blinking monitoring was successfully demonstrated with a response time less than 1 ms. The proposed solution paves the way for ultrasound-based wearable eye-blinking monitoring and offers miniaturization, light weight, low power consumption, high informational security and biosafety.

8.
Opt Express ; 29(15): 23569-23581, 2021 Jul 19.
Article in English | MEDLINE | ID: mdl-34614621

ABSTRACT

A novel tunable whispering gallery modes (WGMs) resonator based on a nematic liquid crystal (LC)-filled capillary and magnetic nanoparticles (MNPs)-coated tapered fiber has been proposed and experimentally demonstrated. Thermo-optic tuning of the WGM resonances has been demonstrated by varying optical pump laser power injected into the MNPs-coated fiber half-taper inside the capillary. The tuning mechanism relies on the change of the effective refractive index (RI) of the nematic LC, caused by the photo-thermal effect of MNPs on the surface of the fiber half-taper inducing a temperature change inside the capillary. Tuning of the WGM resonances with sensitivities of 101.5 ± 3.5 pm/mW and 146.5 ± 3.5 pm/mW and tuning ranges of 1.96 nm and 3.28 nm respectively for the two types of liquid crystals (MLC-7012, MDA-05-2782) has been demonstrated. In addition, the relationship between the optical power of the pump laser and the local temperature of the nematic LC was investigated and the heating rate is estimated as 1.49 °C/mW. The proposed thermo-optic tuning scheme has many potential applications in tunable photonic devices and sensors.

9.
Sensors (Basel) ; 21(2)2021 Jan 17.
Article in English | MEDLINE | ID: mdl-33477256

ABSTRACT

Noncontact ultrasonic detection technology is an effective method to detect damage in time. This paper proposes a noncontact damage detection system based on air-coupled ultrasound and full-field laser vibrometer, which realizes the excitation of relatively single-mode guided waves and the wavefield automatic detection. The system performance is verified through experiments, and the experimental wavenumber is consistent with the theoretical dispersion characteristics of the Lamb wave in the A0 mode. Based on this system, the topography reconstruction algorithms, including the Wavenumber Filtering Algorithm and Spatial Wavenumber Algorithm, were tested and compared with the aluminum alloy plate and the carbon fiber reinforced polymer plate. The results show that, based on the air-coupled ultrasound and full-field laser vibrometer detection system, the Spatial Wavenumber Algorithm has better imaging error and contrast, and the damage edge detection is smoother.

10.
Sensors (Basel) ; 20(21)2020 Oct 28.
Article in English | MEDLINE | ID: mdl-33126557

ABSTRACT

To conduct burst-echo imaging with air-coupled capacitive micromachined ultrasonic transducers (CMUTs) using the same elements in transmission and reception, this work proposes a dedicated and integrated front-end circuit board design to build an imaging system. To the best of the authors' knowledge, this is the first air-coupled CMUT burst-echo imaging using the same elements in transmission and reception. The reported front-end circuit board, controlled by field programmable gate array (FPGA), consisted of four parts: an on-board pulser, a bias-tee, a T/R switch and an amplifier. Working with our 217 kHz 16-element air-coupled CMUT array under 100 V DC bias, the front-end circuit board and imaging system could achieve 22.94 dB signal-to-noise ratio (SNR) in burst-echo imaging in air, which could represent the surface morphology and the three-dimensional form factor of the target. In addition, the burst-echo imaging range of our air-coupled CMUT imaging system, which could work between 52 and 273 mm, was discussed. This work suggests good potential for ultrasound imaging and gesture recognition applications.

11.
Bioact Mater ; 4: 346-357, 2019 Dec.
Article in English | MEDLINE | ID: mdl-31720491

ABSTRACT

Implant-associated infections are generally difficult to cure owing to the bacterial antibiotic resistance which is attributed to the widespread usage of antibiotics. Given the global threat and increasing influence of antibiotic resistance, there is an urgent demand to explore novel antibacterial strategies other than using antibiotics. Recently, using a certain surface topography to provide a more persistent antibacterial solution attracts more and more attention. However, the clinical application of biomimetic nano-pillar array is not satisfactory, mainly because its antibacterial ability against Gram-positive strain is not good enough. Thus, the pillar array should be equipped with other antibacterial agents to fulfill the bacteriostatic and bactericidal requirements of clinical application. Here, we designed a novel model substrate which was a combination of periodic micro/nano-pillar array and TiO2 for basically understanding the topographical bacteriostatic effects of periodic micro/nano-pillar array and the photocatalytic bactericidal activity of TiO2. Such innovation may potentially exert the synergistic effects by integrating the persistent topographical antibacterial activity and the non-invasive X-ray induced photocatalytic antibacterial property of TiO2 to combat against antibiotic-resistant implant-associated infections. First, to separately verify the topographical antibacterial activity of TiO2 periodic micro/nano-pillar array, we systematically investigated its effects on bacterial adhesion, growth, proliferation, and viability in the dark without involving the photocatalysis of TiO2. The pillar array with sub-micron motif size can significantly inhibit the adhesion, growth, and proliferation of Staphylococcus aureus (S. aureus) and Escherichia coli (E. coli). Such antibacterial ability is mainly attributed to a spatial confinement size-effect and limited contact area availability generated by the special topography of pillar array. Moreover, the pillar array is not lethal to S. aureus and E. coli in 24 h. Then, the X-ray induced photocatalytic antibacterial property of TiO2 periodic micro/nano-pillar array in vitro and in vivo will be systematically studied in a future work. This study could shed light on the direction of surface topography design for future medical implants to combat against antibiotic-resistant implant-associated infections without using antibiotics.

12.
Article in English | MEDLINE | ID: mdl-30281447

ABSTRACT

Approximately 80% of men who reach 80 years of age will have some form of prostate cancer. The challenge remains to differentiate benign and malignant lesions. Based on recent research, acoustic angiography, a novel contrast-enhanced ultrasound imaging technique, can provide high-resolution visualization of tissue microvasculature and has demonstrated the ability to differentiate vascular characteristics between healthy and tumor tissue in preclinical studies. We hypothesize that transrectal acoustic angiography may enhance the assessment of prostate cancer. In this paper, we describe the development of a dual frequency, dual-layer colinear array transducer for transrectal acoustic angiography. The probe consists of 64 transmitting (TX) elements with a center frequency of 3 MHz and 128 receiving (RX) elements with a center frequency of 15 MHz. The dimensions of the array are 18 mm in azimuth and 9 mm in elevation. The pitch is [Formula: see text] for TX elements and 140 [Formula: see text] for RX elements. Pulse-echo tests of TX/RX elements and aperture acoustic field measurements were conducted, and both results were compared with the simulation results. Real-time contrast imaging was performed using a Verasonics system and a tissue-mimicking phantom. Nonlinear acoustic responses from microbubble contrast agents at a depth of 35 mm were clearly observed. In vivo imaging in a rodent model demonstrated the ability to detect individual vessels underneath the skin. These results indicate the potential use of the array described herein for acoustic angiography imaging of prostate tumor and identification of regions of neovascularization for the guidance of prostate biopsies.


Subject(s)
Angiography/methods , Image Interpretation, Computer-Assisted/methods , Prostatic Neoplasms/diagnostic imaging , Ultrasonography/methods , Abdomen/blood supply , Abdomen/diagnostic imaging , Animals , Contrast Media , Humans , Male , Microbubbles , Models, Biological , Phantoms, Imaging , Prostate/blood supply , Prostate/diagnostic imaging , Prostatic Neoplasms/blood supply , Rats , Transducers , Ultrasonography/instrumentation
13.
Ultrasonics ; 82: 298-303, 2018 01.
Article in English | MEDLINE | ID: mdl-28941396

ABSTRACT

Recent studies suggest that dual-frequency intravascular ultrasound (IVUS) transducers allow detection of superharmonic bubble signatures, enabling acoustic angiography for microvascular and molecular imaging. In this paper, a dual-frequency IVUS cylindrical array transducer was developed for real-time superharmonic imaging. A reduced form-factor lateral mode transmitter (2.25MHz) was used to excite microbubbles effectively at 782kPa with single-cycle excitation while still maintaining the small size and low profile (5Fr) (3Fr=1mm) for intravascular imaging applications. Superharmonic microbubble responses generated in simulated microvessels were captured by the high frequency receiver (30MHz). The axial and lateral full-width half-maximum of microbubbles in a 200-µm-diameter cellulose tube were measured to be 162µm and 1039µm, respectively, with a contrast-to-noise ratio (CNR) of 16.6dB. Compared to our previously reported single-element IVUS transducers, this IVUS array design achieves a higher CNR (16.6dBvs 11dB) and improved axial resolution (162µmvs 616µm). The results show that this dual-frequency IVUS array transducer with a lateral-mode transmitter can fulfill the native design requirement (∼3-5Fr) for acoustic angiography by generating nonlinear microbubble responses as well as detecting their superharmonic responses in a 5Fr form factor.


Subject(s)
Angiography/instrumentation , Ultrasonography/instrumentation , Equipment Design , In Vitro Techniques , Microbubbles , Microvessels , Phantoms, Imaging , Transducers
14.
Article in English | MEDLINE | ID: mdl-27775903

ABSTRACT

Techniques to image the microvasculature may play an important role in imaging tumor-related angiogenesis and vasa vasorum associated with vulnerable atherosclerotic plaques. However, the microvasculature associated with these pathologies is difficult to detect using traditional B-mode ultrasound or even harmonic imaging due to small vessel size and poor differentiation from surrounding tissue. Acoustic angiography, a microvascular imaging technique that utilizes superharmonic imaging (detection of higher order harmonics of microbubble response), can yield a much higher contrast-to-tissue ratio than second harmonic imaging methods. In this paper, two dual-frequency transducers using lateral mode transmitters were developed for superharmonic detection and acoustic angiography imaging in intracavity applications. A single element dual-frequency intravascular ultrasound transducer was developed for concept validation, which achieved larger signal amplitude, better contrast-to-noise ratio (CNR), and pulselength compared to the previous work. A dual-frequency [Pb(Mg1/3Nb2/3)O3]-x[PbTiO3] array transducer was then developed for superharmonic imaging with dynamic focusing. The axial and lateral sizes of the microbubbles in a 200- [Formula: see text] tube were measured to be 269 and [Formula: see text], respectively. The maximum CNR was calculated to be 22 dB. These results show that superharmonic imaging with a low frequency lateral mode transmitter is a feasible alternative to thickness mode transmitters when the final transducer size requirements dictate design choices.


Subject(s)
Acoustics/instrumentation , Angiography/instrumentation , Contrast Media/chemistry , Ultrasonography/instrumentation , Equipment Design , Humans , Microbubbles , Transducers
15.
Article in English | MEDLINE | ID: mdl-26661069

ABSTRACT

Ultrasound imaging with high resolution and large penetration depth has been increasingly adopted in medical diagnosis, surgery guidance, and treatment assessment. Conventional ultrasound works at a particular frequency, with a [Formula: see text] fractional bandwidth of [Formula: see text], limiting the imaging resolution or depth of field. In this paper, a bifrequency colinear array with resonant frequencies of 8 and 20 MHz was investigated to meet the requirements of resolution and penetration depth for a broad range of ultrasound imaging applications. Specifically, a 32-element bifrequency colinear array was designed and fabricated, followed by element characterization and real-time sectorial scan (S-scan) phantom imaging using a Verasonics system. The bifrequency colinear array was tested in four different modes by switching between low and high frequencies on transmit and receive. The four modes included the following: 1) transmit low, receive low; 2) transmit low, receive high; 3) transmit high, receive low; and 4) transmit high, receive high. After testing, the axial and lateral resolutions of all modes were calculated and compared. The results of this study suggest that bifrequency colinear arrays are potential aids for wideband fundamental imaging and harmonic/subharmonic imaging.


Subject(s)
Ultrasonography/instrumentation , Equipment Design , Phantoms, Imaging , Signal-To-Noise Ratio , Transducers
16.
Food Chem ; 173: 210-7, 2015 Apr 15.
Article in English | MEDLINE | ID: mdl-25466014

ABSTRACT

Zinc is an essential trace element for human growth and development. In this work, zinc-chelating peptides from rapeseed protein hydrolysates produced with alcalase were investigated by affinity chromatography with immobilized zinc and Sephadex G-25 gel filtration. Four small peptides, namely, Ala-Arg, Asn-Ser-Met (NSM), Gly-Lys-Arg, and Glu-Pro-Ser-His, were obtained and identified by reversed-phase high-performance liquid chromatography and electrospray ionization mass spectrometry. The zinc-chelating ability of the four peptides was further validated by inductively coupled plasma atomic emission spectrometry (ICP-AES). NSM was found to exhibit the highest zinc-chelating rate, which was better than that of reduced glutathione. We speculated that the Asn residue at the amino-terminus might facilitate this zinc-chelating ability. Therefore, utilizing small peptides from rapeseed protein as novel carriers for zinc supplement was feasible.


Subject(s)
Brassica rapa/chemistry , Chelating Agents/isolation & purification , Peptides/isolation & purification , Protein Hydrolysates/analysis , Zinc/metabolism , Amino Acid Sequence , Amino Acids/metabolism , Chelating Agents/metabolism , Chromatography, Gel , Drug Carriers , Humans , Molecular Sequence Data , Peptides/metabolism
17.
Bioresour Technol ; 153: 315-21, 2014 Feb.
Article in English | MEDLINE | ID: mdl-24374364

ABSTRACT

The objective of this study was to evaluate the effectiveness of high-frequency focused ultrasound (HFFU) in microalgal cell disruption. Two microalgal species including Scenedesmus dimorphus and Nannochloropsis oculata were treated by a 3.2-MHz, 40-W focused ultrasound and a 100-W, low-frequency (20kHz) non-focused ultrasound (LFNFU). The results demonstrated that HFFU was effective in the disruption of microalgal cells, indicated by significantly increased lipid fluorescence density, the decrease of cell sizes, and the increase of chlorophyll a fluorescence density after treatments. Compared with LFNFU, HFFU treatment was more energy efficient. The combination of high and low frequency treatments was found to be even more effective than single frequency treatment at the same processing time, indicating that frequency played a critical role in cell disruption. In both HFFU and LFNFU treatments, the effectiveness of cell disruption was found to be dependent on the cell treated.


Subject(s)
Cell Fractionation/methods , Microalgae/cytology , Ultrasonics/methods , Chlorophyll/metabolism , Chlorophyll A , Colony Count, Microbial , Fluorescence , Lipids/chemistry , Microalgae/growth & development , Microalgae/metabolism , Oxazines/metabolism , Staining and Labeling , Ultrasonics/instrumentation
18.
Lab Chip ; 11(7): 1280-5, 2011 Apr 07.
Article in English | MEDLINE | ID: mdl-21301739

ABSTRACT

Manipulation of microscale particles and fluid liquid droplets is an important task for lab-on-a-chip devices for numerous biological researches and applications, such as cell detection and tissue engineering. Particle manipulation techniques based on surface acoustic waves (SAWs) appear effective for lab-on-a-chip devices because they are non-invasive, compatible with soft lithography micromachining, have high energy density, and work for nearly any type of microscale particles. Here we review the most recent research and development of the past two years in SAW based particle and liquid droplet manipulation for lab-on-a-chip devices including particle focusing and separation, particle alignment and patterning, particle directing, and liquid droplet delivery.


Subject(s)
Acoustics/instrumentation , Lab-On-A-Chip Devices , Microtechnology/methods , Humans , Surface Properties
SELECTION OF CITATIONS
SEARCH DETAIL