Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
Add more filters








Publication year range
1.
Bioengineering (Basel) ; 11(2)2024 Feb 06.
Article in English | MEDLINE | ID: mdl-38391648

ABSTRACT

We report, for the first time, the full-field 3D strain distribution of the muscle-tendon junction (MTJ). Understanding the strain distribution at the junction is crucial for the treatment of injuries and to predict tear formation at this location. Three-dimensional full-field strain distribution of mouse MTJ was measured using X-ray computer tomography (XCT) combined with digital volume correlation (DVC) with the aim of understanding the mechanical behavior of the junction under tensile loading. The interface between the Achilles tendon and the gastrocnemius muscle was harvested from adult mice and stained using 1% phosphotungstic acid in 70% ethanol. In situ XCT combined with DVC was used to image and compute strain distribution at the MTJ under a tensile load (2.4 N). High strain measuring 120,000 µÎµ, 160,000 µÎµ, and 120,000 µÎµ for the first principal stain (εp1), shear strain (γ), and von Mises strain (εVM), respectively, was measured at the MTJ and these values reduced into the body of the muscle or into the tendon. Strain is concentrated at the MTJ, which is at risk of being damaged in activities associated with excessive physical activity.

2.
J Colloid Interface Sci ; 637: 500-512, 2023 May.
Article in English | MEDLINE | ID: mdl-36724664

ABSTRACT

HYPOTHESIS: Characterizing the microstructure of an ice/surface interface and its effect on the icephobic behavior of surfaces remains a significant challenge. Introducing X-ray Computed Tomography (XCT) can provide unprecedented insights into the internal (porosity) and interfacial structures, i.e. wetting regime, between (super)hydrophobic surfaces and ice by visualizing these optically inaccessible regions. EXPERIMENTS: Frozen droplets with controlled volume were deposited on top of metallic and polymeric substrates with different levels of wettability. Different modes of XCT (3D and 4D) were utilized to obtain information on the internal and interfacial structure of the ice/surface system. The results were supplemented by conventional surface analysis techniques, including optical profilometry and contact angle measurements. FINDINGS: Using XCT on ice/surface systems, the 3D and 4D (imaging with temporal resolution) structural information can be visualized. From these datasets, qualitative and quantitative results were obtained, not only for characterizing the interface but also for analyzing the entire droplet/surface system, e.g., measurement of porosity size, shape, and location. These results highlight the potential of XCT in the characterization of both droplets and substrates and proves that the technique can aid to develop hydrophobic surfaces for use as icephobic materials.

3.
J Mech Behav Biomed Mater ; 138: 105636, 2023 02.
Article in English | MEDLINE | ID: mdl-36608532

ABSTRACT

Exposure to X-ray radiation for an extended amount of time can cause damage to the bone tissue and therefore affect its mechanical properties. Specifically, high-resolution X-ray Computed Tomography (XCT), in both synchrotron and lab-based systems, has been employed extensively for evaluating bone micro-to-nano architecture. However, to date, it is still unclear how long exposures to X-ray radiation affect the mechanical properties of trabecular bone, particularly in relation to lab-XCT systems. Indentation has been widely used to identify local mechanical properties such as hardness and elastic modulus of bone and other biological tissues. The purpose of this study is therefore, to use indentation and XCT-based investigative tools such as digital volume correlation (DVC) to assess the microdamage induced by long exposure of trabecular bone tissue to X-ray radiation and how this affects its local mechanical properties. Trabecular bone specimens were indented before and after X-ray exposures of 33 and 66 h, where variation of elastic modulus was evaluated at every stage. The resulting elastic modulus was decreased, and micro-cracks appeared in the specimens after the first long X-ray exposure and crack formation increased after the second exposure. High strain concentration around the damaged tissue exceeding 1% was also observed from DVC analysis. The outcomes of this study show the importance of designing appropriate XCT-based experiments in lab systems to avoid degradation of the bone tissue mechanical properties due to radiation and these results will help to inform future studies that require long X-ray exposure for in situ experiments or generation of reliable subject-specific computational models.


Subject(s)
Bone and Bones , Cancellous Bone , Cancellous Bone/diagnostic imaging , Bone and Bones/diagnostic imaging , Tomography, X-Ray Computed/methods , Elastic Modulus
4.
Bioact Mater ; 19: 406-417, 2023 Jan.
Article in English | MEDLINE | ID: mdl-35574056

ABSTRACT

The successful application of magnesium (Mg) alloys as biodegradable bone substitutes for critical-sized defects may be comprised by their high degradation rate resulting in a loss of mechanical integrity. This study investigates the degradation pattern of an open-porous fluoride-coated Mg-based scaffold immersed in circulating Hanks' Balanced Salt Solution (HBSS) with and without in situ cyclic compression (30 N/1 Hz). The changes in morphological and mechanical properties have been studied by combining in situ high-resolution X-ray computed tomography mechanics and digital volume correlation. Although in situ cyclic compression induced acceleration of the corrosion rate, probably due to local disruption of the coating layer where fatigue microcracks were formed, no critical failures in the overall scaffold were observed, indicating that the mechanical integrity of the Mg scaffolds was preserved. Structural changes, due to the accumulation of corrosion debris between the scaffold fibres, resulted in a significant increase (p < 0.05) in the material volume fraction from 0.52 ± 0.07 to 0.47 ± 0.03 after 14 days of corrosion. However, despite an increase in fibre material loss, the accumulated corrosion products appear to have led to an increase in Young's modulus after 14 days as well as lower third principal strain (εp3) accumulation (-91000 ± 6361 µÎµ and -60093 ± 2414 µÎµ after 2 and 14 days, respectively). Therefore, this innovative Mg scaffold design and composition provide a bone replacement, capable of sustaining mechanical loads in situ during the postoperative phase allowing new bone formation to be initially supported as the scaffold resorbs.

5.
Materials (Basel) ; 15(6)2022 Mar 20.
Article in English | MEDLINE | ID: mdl-35329742

ABSTRACT

The great potential of Extrusion Additive Manufacturing (EAM) for structural prototyping in the automotive industry is severely limited by the directional bias in the build direction. The layerwise fabrication leads to reduced mechanical properties at the layer-to-layer interface compared to the bulk of the strand. Especially for the often-used semi-crystalline thermoplastics, the mechanical properties strongly depend on the processing parameters, even more so if short fibers are used as fillers. Therefore, ideal processing windows in which the mechanical strength and modulus in the z-direction reach their maximum can be identified for these parameters, resulting in a reduced directional bias. The influence of the EAM processing parameters on mechanical strength has already been investigated, correlating strength with thermal conditions during printing. However, these considerations did not distinguish between the thermal effect on the polymer properties, the formation of voids and pores at the layer interface, and the resulting fiber orientation for different strand proportions. Therefore, in this study, the effect of different processing temperatures and layer heights on the pore size and distribution, as well as the fiber orientation in the different regions of the mesostructure was investigated using X-ray Computed Tomography (XCT).

6.
J Microsc ; 285(3): 156-166, 2022 03.
Article in English | MEDLINE | ID: mdl-32530049

ABSTRACT

The mechanical behaviour of regenerated bone tissue during fracture healing is key in determining its ability to withstand physiological loads. However, the strain distribution in the newly formed tissue and how this influences the way a fracture heals it is still unclear. X-ray Computed Tomography (XCT) has been extensively used to assess the progress of mineralised tissues in regeneration and when combined with in situ mechanics and digital volume correlation (DVC) has been proven a powerful tool to understand the mechanical behaviour and full-field three-dimensional (3D) strain distribution in bone. The purpose of this study is therefore to use in situ XCT mechanics and DVC to investigate the strain distribution and load-bearing capacity in a regenerating fracture in the diaphyseal bone, using a rodent femoral fracture model stabilised by external fixation. Rat femurs with 1 mm and 2 mm osteotomy gaps were tested under in situ XCT step-wise compression in the apparent elastic region. High strain was present in the newly formed bone (εp1 and εp3 reaching 29 000 µÎµ and -43 000 µÎµ, respectively), with a wide variation and inhomogeneity of the 3D strain distribution in the regenerating tissues of the fracture gap, which is directly related to the presence of unmineralised tissue observed in histological images. The outcomes of this study will contribute in understanding natural regenerative ability of bone and its mechanical behaviour under loading.


Subject(s)
Bone and Bones , Femoral Fractures , Animals , Osteogenesis , Rats , Tomography, X-Ray Computed
7.
Acta Biomater ; 127: 338-352, 2021 06.
Article in English | MEDLINE | ID: mdl-33831571

ABSTRACT

Magnesium (Mg) and its alloys are very promising degradable, osteoconductive and osteopromotive materials to be used as regenerative treatment for critical-sized bone defects. Under load-bearing conditions, Mg alloys must display sufficient morphological and mechanical resemblance to the native bone they are meant to replace to provide adequate support and enable initial bone bridging. In this study, unique highly open-porous Mg-based scaffolds were mechanically and morphologically characterised at different scales. In situ X-ray computed tomography (XCT) mechanics, digital volume correlation (DVC), electron microscopy and nanoindentation were combined to assess the influence of material properties on the apparent (macro) mechanics of the scaffold. The results showed that Mg exhibited a higher connected structure (38.4mm-3 and 6.2mm-3 for Mg and trabecular bone (Tb), respectively) and smaller spacing (245µm and 629µm for Mg and Tb, respectively) while keeping an overall appropriate porosity of 55% in the range of trabecular bone (30-80%). This fully connected and highly porous structure promoted lower local strain compared to the trabecular bone structure at material level (i.e. -22067 ± 8409µÎµ and -40120 ± 18364µÎµ at 6% compression for Mg and trabecular bone, respectively) and highly ductile mechanical behaviour at apparent level preventing premature scaffold failure. Furthermore, the Mg scaffolds exceeded the physiological strain of bone tissue generated in daily activities such as walking or running (500-2000µÎµ) by one order of magnitude. The yield stress was also found to be close to trabecular bone (2.06MPa and 6.67MPa for Mg and Tb, respectively). Based on this evidence, the study highlights the overall biomechanical suitability of an innovative Mg-based scaffold design to be used as a treatment for bone critical-sized defects. STATEMENT OF SIGNIFICANCE: Bone regeneration remains a challenging field of research where different materials and solutions are investigated. Among the variety of treatments, biodegradable magnesium-based implants represent a very promising possibility. The novelty of this study is based on the characterisation of innovative magnesium-based implants whose structure and manufacturing have been optimised to enable the preservation of mechanical integrity and resemble bone microarchitecture. It is also based on a multi-scale approach by coupling high-resolution X-ray computed tomography (XCT), with in situ mechanics, digital volume correlation (DVC) as well as nano-indentation and electron-based microscopy imaging to define how degradable porous Mg-based implants fulfil morphological and mechanical requirements to be used as critical bone defects regeneration treatment.


Subject(s)
Magnesium , Tissue Scaffolds , Biocompatible Materials , Bone Regeneration , Magnesium/pharmacology , Porosity
8.
J Mech Behav Biomed Mater ; 115: 104298, 2021 03.
Article in English | MEDLINE | ID: mdl-33445104

ABSTRACT

The overall mechanical behaviour of cortical bone is strongly dependant on its microstructure. X-ray computed tomography (XCT) has been widely used to identify the microstructural morphology of cortical tissue (i.e. pore network, Haversian and Volkmann's canals). However, the connection between microstructure and mechanics of cortical bone during plastic deformation is unclear. Hence, the purpose of this study is to provide an in-depth evaluation of the interplay of plastic strain building up in relation to changes in the canal network for cortical bone tissue. In situ step-wise XCT indentation was used to introduce a localised load on the surface of the tissue and digital volume correlation (DVC) was employed to assess the three-dimensional (3D) full-field plastic strain distribution in proximity of the indent. It was observed that regions adjacent to the imprint were under tensile strain, whereas the volume underneath experienced compressive strain. Canal loss and disruption was detected in regions of higher compressive strains exceeding -20000 µÎµ and crack formation occurred in specimens where Haversian canals were running parallel to the indentation tip. The results of this study outline the relationship between the micromechanical and structural behaviour of cortical bone during plastic deformation, providing information on cortical tissue fracture pathways.


Subject(s)
Cortical Bone , Fractures, Bone , Bone and Bones/diagnostic imaging , Cortical Bone/diagnostic imaging , Haversian System , Humans , Tomography, X-Ray Computed
9.
Pharm Res ; 37(12): 231, 2020 Oct 29.
Article in English | MEDLINE | ID: mdl-33123816

ABSTRACT

PURPOSE: This work details experimental observations on the effect of liquid flow percolating through packed beds of crystals to elucidate how the filtration pressure severely alters the size distribution and crystal shape. Pressure filtration is widely used in the pharmaceutical industry, and frequently results in undesired size distribution changes that hinder further processing. METHODS: The percolation methodology presented fixes fluid flow through a bed of crystals, resulting in a pressure over the bed. X-ray computed tomography (XCT) provided detailed observations of the bed structure. Detailed 2D particle size data was obtained using automated microscopy and was analysed using an in-house developed tool. RESULTS: Crystal breakage is observed when the applied pressure exceeds a critical pressure: 0.5-1 bar for ibuprofen, 1-2 bar for ß-L glutamic acid (LGA) and 2-2.5 bar for para amino benzoic acid (PABA). X-ray computed tomography showed significant changes in bed density under the applied pressure. Size analysis and microscope observations showed two modes of breakage: (i) snapping of long crystals and (ii) shattering of crystals. CONCLUSION: LGA and PABA have a similar breakage strength (50 MPa), ibuprofen is significantly weaker (9 MPa). Available breakage strength data may be correlated to the volumetric Gibbs free energy. Data from 12 and 35 mm bed diameters compares well to literature data in a 80 mm filter; the smaller, easy to operate percolation unit is a versatile tool to assess crystal breakage in filtration operations.


Subject(s)
Chemistry, Pharmaceutical/methods , Drug Compounding/methods , Filtration , Crystallization , Hydrodynamics , Particle Size , Pressure , Solutions
10.
Environ Sci Pollut Res Int ; 27(31): 38407-38421, 2020 Nov.
Article in English | MEDLINE | ID: mdl-32124284

ABSTRACT

Bentonite-based geomaterials are included in the designs of geological repository planning in most countries, especially in high-level radioactive waste disposal. Physical integrity of the bentonite sealant is key in assuring its hydraulic and retention properties, which affect the long-term performance of the repositories. Examination of the internal textures and structures of bentonite has been challenging until recently. Here, X-ray computed tomography (XCT) is applied to improve the textural and structural characterization of natural and man-made bentonite samples. Based on these initial analyses, clear benefits have been identified compared with conventional bentonite research methods. First, applying XCT prior to destructive analytical methods provides means to distinguish secondary features or in situ textures. It allows to eliminate false interpretations due to sample deformation and guides subsampling. Second, XCT images add the third dimension to analyses, allowing larger spatial coverage in less time. Overall, findings support the application of XCT for reducing uncertainties related to physical characterization of bentonite samples, both natural and industrial. They also show that XCT has potential to be developed to support quality assurance processes for bentonite sealant manufacturing.


Subject(s)
Radioactive Waste , Refuse Disposal , Bentonite , Geology , Tomography, X-Ray Computed
11.
Materials (Basel) ; 12(23)2019 Nov 29.
Article in English | MEDLINE | ID: mdl-31795430

ABSTRACT

Corrosion is a challenging problem for marine concrete infrastructure projects. In this study, an intelligent OH--regulated microcapsule is designed to prevent reinforcement corrosion, taking ethylcellulose (EC) as shell material and calcium oxide (CaO) as core material. X-ray computed tomography (XCT) is used to trace and contrast the corrosion profiles of the concrete reinforcement bar with and without the microcapsule. The results show that the OH--regulated microcapsule exhibits effective corrosion protection by delaying corrosion initiation and cracking. An SEM study revealed that the microcapsule could be broken as Cl- invades the concrete. However, intelligent OH- regulation was realized by releasing CaO.

SELECTION OF CITATIONS
SEARCH DETAIL