Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 167
Filtrar
1.
Artigo em Alemão | MEDLINE | ID: mdl-39143426

RESUMO

BACKGROUND AND OBJECTIVES: Sarcopenia is the generalized loss of muscle strength, mass, and function. The aim was to investigate whether pretherapeutic sarcopenia, as determined by the psoas muscles, affects therapy-mediated toxicity in patients with malignant melanoma undergoing immunotherapy. PATIENTS AND METHODS: Measurement of psoas musculature was performed pretherapeutically using computed tomography at the level of the third lumbar vertebra in the axial plane in 75 patients between January 2011 and December 2020. Sarcopenia was defined using the psoas muscle index (PMI). Immune-related toxicity was retrospectively assessed. RESULTS: Treatment-related toxicity was recorded in 33 of the 75 patients (44%). Of these, 16 patients (36.2%) experienced dose-limiting severe events (DLT). Pretherapeutic sarcopenia was identified in 25 patients (33.3%). Comparative analysis showed that the patients with a DLT had lower PMI values compared with the patient group without a DLT (4.65 ± 1.33 vs. 5.79 ± 1.67 cm2m-2, p = 0.015) (odds ratio = 0.60, 95% confidence interval 0.40-0.92, p = 0.02). CONCLUSIONS: Pretherapeutic sarcopenia measured based on the psoas muscle is not a significant predictor of immune-mediated toxicity in patients with malignant melanoma treated with immune checkpoint inhibitors. Patients with DLT have lower values for the psoas muscle parameters PMI compared to the group of patients without DLT.

2.
J Cardiovasc Magn Reson ; : 101068, 2024 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-39079602

RESUMO

PURPOSE: Diagnosing myocarditis relies on multimodal data including magnetic resonance imaging (MRI), clinical symptoms, and blood values. The correct interpretation and integration of MRI findings requires radiological expertise and knowledge. We aimed to investigate the performance of Generative Pre-trained Transformer 4 (GPT-4), a large language model, for report-based medical decision-making in the context of cardiac MRI for suspected myocarditis. METHODS: This retrospective study includes MRI reports from 396 patients with suspected myocarditis and eight centers, respectively. MRI reports and patient data including blood values, age, and further clinical information were provided to GPT-4 and to radiologists with 1 (Resident 1), 2 (Resident 2), and 4 years (Resident 3) of experience in cardiovascular MRI and knowledge of the 2018 Lake Louise Criteria. The final impression of the report regarding the radiological assessment of whether myocarditis is present or not was not provided. The performance of GPT-4 and of the human readers were compared to a consensus reading (two board-certified radiologists with 8 and 10 years of experience in cardiovascular MRI). Sensitivity, specificity, and accuracy were calculated. RESULTS: GPT-4 yielded an accuracy of 83%, sensitivity of 90%, and specificity of 78%, which was comparable to the physician with 1 year of experience (R1: 86%, 90%, 84%, p=.14) and lower than that of more experienced physicians (R2: 89%, 86%, 91%, p=.007 and R3: 91%, 85%, 96%, p<.001). GPT-4 and human readers showed a higher diagnostic performance when results from T1- and T2-mapping sequences were part of the reports, for Residents 1 and Resident 3 with statistical significance (p=.004 and p=.02, respectively). CONCLUSION: GPT-4 yielded good accuracy for diagnosing myocarditis based on MRI reports in a large dataset from multiple centers and therefore holds the potential to serve as a diagnostic decision supporting tool in this capacity, particularly for less experienced physicians. Further studies are required to explore the full potential and elucidate educational aspects of the integration of large language models in medical decision-making.

3.
Rofo ; 2024 Jul 22.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-39038457

RESUMO

PURPOSE: The prevalent coronavirus disease 2019 (COVID-19) pandemic has spread throughout the world and is considered a serious threat to global health. The prognostic role of thoracic lymphadenopathy in COVID-19 is unclear. The aim of the present meta-analysis was to analyze the prognostic role of thoracic lymphadenopathy for the prediction of 30-day mortality in patients with COVID-19. MATERIALS AND METHODS: The MEDLINE library, Cochrane, and SCOPUS databases were screened for associations between CT-defined features and mortality in COVID-19 patients up to June 2021. In total, 21 studies were included in the present analysis. The quality of the included studies was assessed by the Newcastle-Ottawa Scale. The meta-analysis was performed using RevMan 5.3. Heterogeneity was calculated by means of the inconsistency index I2. DerSimonian and Laird random-effect models with inverse variance weights were performed without any further correction. RESULTS: The included studies comprised 4621 patients. The prevalence of thoracic lymphadenopathy varied between 1 % and 73.4 %. The pooled prevalence was 16.7 %, 95 % CI = (15.6 %; 17.8 %). The hospital mortality was higher in patients with thoracic lymphadenopathy (34.7 %) than in patients without (20.0 %). The pooled odds ratio for the influence of thoracic lymphadenopathy on mortality was 2.13 (95 % CI = [1.80-2.52], p < 0.001). CONCLUSION: The prevalence of thoracic lymphadenopathy in COVID-19 is 16.7 %. The presence of thoracic lymphadenopathy is associated with an approximately twofold increase in the risk for hospital mortality in COVID-19. KEY POINTS: · The prevalence of lymphadenopathy in COVID-19 is 16.7 %.. · Patients with lymphadenopathy in COVID-19 have a higher risk of mortality during hospitalization.. · Lymphadenopathy nearly doubles mortality and plays an important prognostic role.. CITATION FORMAT: · Bucher AM, Sieren M, Meinel F et al. Prevalence and prognostic role of thoracic lymphadenopathy in Covid-19. Fortschr Röntgenstr 2024; DOI: 10.1055/a-2293-8132.

4.
Sci Rep ; 14(1): 15986, 2024 07 10.
Artigo em Inglês | MEDLINE | ID: mdl-38987641

RESUMO

The purpose of the present study is to evaluate whether an online reference system (ORS, STATdx Elsevier, Amsterdam, Netherlands) impacts finding the histologically confirmed diagnosis of rare or atypical abdominal tumors and lesions in radiologic imaging. In total, 101 patients with rare tumor entities or lesions and atypical manifestations of common tumors were enrolled retrospectively. Blinded readings were performed by four radiologists with varying levels of experience, who reported on: (a) correct diagnosis (CD), (b) time needed to find the diagnosis, and (c) diagnostic confidence, initially without followed by the assistance of the ORS. The experienced reader (3 years of experience post-residency, CD 49.5%), as well as the advanced reader with 1 year of experience post-residency (CD 43.6%), and a resident with 5 years of experience (CD 46.5%) made the correct diagnosis more frequently compared to the less experienced reader (CD 25.7%). A significant improvement in making the correct diagnosis was only achieved by the advanced reader, the resident with 5 years of experience (CD with ORS 58.4%; p < 0.001). The advanced reader with 1 year of experience post-residency improved slightly (CD ORS 47.5%). The experienced reader (CD ORS 50.5%) and the less experienced reader (CD ORS 27.7%) did not improve significantly. The overall subjective confidence increased significantly when ORS was used (3.2 ± 0.9 vs. 3.8 ± 0.9; p < 0.001). While the ORS had a positive impact on making the correct diagnosis throughout all readers, it favored radiologists with more clinical experience rather than inexperienced residents. Moreover, the ORS increased the diagnostic confidence of all radiologists significantly. In conclusion, the ORS had no significant impact on the diagnosis of rare or atypical abdominal tumors and lesions except for one reader. The greatest benefit is the increase in diagnostic confidence.


Assuntos
Neoplasias Abdominais , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Adulto , Neoplasias Abdominais/diagnóstico , Neoplasias Abdominais/patologia , Estudos Retrospectivos , Idoso de 80 Anos ou mais , Adulto Jovem , Adolescente , Sistemas On-Line
5.
Artigo em Inglês | MEDLINE | ID: mdl-39007783

RESUMO

BACKGROUND AND AIMS: Our purpose was to assess the impact of muscle quality on overall survival (OS) in patients with advanced HCC. METHODS: This is a subanalysis of the SORAMIC trial. Overall, 363 patients were included. The SIRT/Sorafenib treatment group comprised 182 patients and the sorafenib group 181 patients. Myosteatosis was defined as skeletal muscle density (SMD) < 41 HU for patients with a body mass index up to 24.9 kg/m2 and <33 HU for patients with a body mass index ≥25 kg/m2. Albumin-gauge score was calculated as follows: serum albumin (g/dL) × SMD (HU). To assess the impact of muscle quality on clinical variables and OS, a Cox regression model was used. Hazard ratios are presented together with 95 % confidence intervals (95 % CI). Kaplan-Meier curves were used for survival analysis. RESULTS: In the SIRT/sorafenib cohort, low albumin-gauge score was an independent predictor of worse OS, HR = 1.74, CI 95% (1.16-2.62), p = 0.01. In the sorafenib cohort, muscle quality parameters did not predict OS. In alcohol-induced HCC (n = 129), myosteatosis independently predicted OS, HR = 1.85, CI 95% (1.10; 3.12), p = 0.02. In viral-induced HCC (n = 99), parameters of muscle quality did not predict OS. In patients with NASH/Non-alcoholic fatty liver disease (NAFLD) induced HCC, albumin-gauge score was a strong independent predictor of worse OS in the subgroup undergoing combined treatment with SIRT and sorafenib, HR = 9.86, CI 95% (1.12; 86.5), p = 0.04. CONCLUSIONS: Myosteatosis predicts independently worse OS in patients with alcohol-induced HCC undergoing combined treatment with SIRT and sorafenib. In patients with NASH/NAFLD induced HCC undergoing treatment with SIRT and sorafenib, albumin-gauge score predicts independently worse OS. IMPACT AND IMPLICATIONS: Associations between parameters of muscle quality and OS are different in accordance to the treatment strategy and etiology of HCC. These findings highlight the prognostic potential of skeletal muscle quality in patients with advanced HCC.

6.
J Cachexia Sarcopenia Muscle ; 15(4): 1430-1440, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38859660

RESUMO

BACKGROUND: Acute pulmonary embolism (APE) is a potentially life-threatening disorder, emphasizing the importance of accurate risk stratification and survival prognosis. The exploration of imaging biomarkers that can reflect patient survival holds the potential to further enhance the stratification of APE patients, enabling personalized treatment and early intervention. Therefore, in this study, we develop computed tomography pulmonary angiography (CTPA) radiomic signatures for the prognosis of 7- and 30-day all-cause mortality in patients with APE. METHODS: Diagnostic CTPA images from 829 patients with APE were collected. Two hundred thirty-four features from each skeletal muscle (SM), intramuscular adipose tissue (IMAT) and both tissues combined (SM + IMAT) were calculated at the level of thoracic vertebra 12. Radiomic signatures were derived using 10 times repeated three-fold cross-validation on the training data for SM, IMAT and SM + IMAT for predicting 7- and 30-day mortality independently. The performance of the radiomic signatures was then evaluated on held-out test data and compared with the simplified pulmonary embolism severity index (sPESI) score, a well-established biomarker for risk stratification in APE. Predictive accuracy was assessed by the area under the receiver operating characteristic curve (AUC) with a 95% confidence interval (CI), sensitivity and specificity. RESULTS: The radiomic signatures based on IMAT and a combination of SM and IMAT (SM + IMAT) achieved moderate performance for the prediction of 30-day mortality on test data (IMAT: AUC = 0.68, 95% CI [0.57-0.78], sensitivity = 0.57, specificity = 0.73; SM + IMAT: AUC = 0.70, 95% CI [0.60-0.79], sensitivity = 0.74, specificity = 0.54). Radiomic signatures developed for predicting 7-day all-cause mortality showed overall low performance. The clinical signature, that is, sPESI, achieved slightly better performance in terms of AUC on test data compared with the radiomic signatures for the prediction of both 7- and 30-day mortality on the test data (7 days: AUC = 0.73, 95% CI [0.67-0.79], sensitivity = 0.92, specificity = 0.16; 30 days: AUC = 0.74, 95% CI [0.66-0.82], sensitivity = 0.97, specificity = 0.16). CONCLUSIONS: We developed and tested radiomic signatures for predicting 7- and 30-day all-cause mortality in APE using a multicentric retrospective dataset. The present multicentre work shows that radiomics parameters extracted from SM and IMAT can predict 30-day all-cause mortality in patients with APE.


Assuntos
Tecido Adiposo , Músculo Esquelético , Embolia Pulmonar , Humanos , Embolia Pulmonar/mortalidade , Embolia Pulmonar/diagnóstico por imagem , Masculino , Feminino , Tecido Adiposo/diagnóstico por imagem , Músculo Esquelético/diagnóstico por imagem , Pessoa de Meia-Idade , Idoso , Prognóstico , Doença Aguda , Angiografia por Tomografia Computadorizada/métodos , Radiômica
7.
Clin Nutr ESPEN ; 61: 274-280, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38777443

RESUMO

OBJECTIVE: Allogeneic hematopoietic stem cell transplantation (allo-HSCT) represents the only curative treatment option for several hematological neoplasms. This study aimed to assess the parameters of body composition as predictors of post-transplant overall survival (OS) and adverse events in patients with leukemia, myelodysplastic syndromes (MDS), and myeloproliferative neoplasms (MPN). METHODS: This was a retrospective study of 122 adult patients who underwent their first allo-HSCT. The CT-based semi-automated measurement of subcutaneous adipose tissue (SAT), visceral adipose tissue (VAT), visceral-to-subcutaneous fat ratio (VSR), sarcopenia in terms of skeletal muscle index (SMI), and myosteatosis based on the skeletal muscle radiation attenuation (SM-RA) was performed. Cox regression analysis was used to assess the association of body composition parameters with OS. RESULTS: In the univariate analysis, low SAT and myosteatosis were associated with lower OS (hazard ratio [HR] 2.02, 95% confidence interval [CI] 1.16-3.51, p = 0.01) and (HR 2.50, 95% CI 1.48-4.25, p =< 0.001), respectively. This association remained significant after adjusting for relevant covariates, with HR 2.32, 95% CI 1.23-4.38, p = 0.01 and HR 2.86, 95% CI 1.51-5.43, p =< 0.001, respectively. On the contrary, VAT, VSR, sarcopenia, and sarcopenic obesity were not statistically significant in OS. Severe post-transplant adverse events were more common in the low SAT group (odds ratio [OR] 3.12, 95% CI 1.32-7.40, p = 0.01) and OR 3.17, 95% CI 1.31-7.70, p =< 0.01 in the age- and sex-adjusted analysis. CONCLUSION: Low SAT and myosteatosis may contribute to an increased risk of post-transplant mortality, while low SAT appears to increase the risk of severe post-transplant adverse events.


Assuntos
Composição Corporal , Transplante de Células-Tronco Hematopoéticas , Gordura Subcutânea , Humanos , Masculino , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Adulto , Prognóstico , Sarcopenia , Idoso , Transplante Homólogo , Músculo Esquelético , Gordura Intra-Abdominal , Adulto Jovem
8.
Clin Neuroradiol ; 2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38814452

RESUMO

PURPOSE: This study analyzes the long-term clinical and angiographic outcomes of the Derivo Embolization Device (DED), an advanced flow diverter device with an electropolished surface, for the treatment of intracranial aneurysms. METHODS: A consecutive series of 101 patients (mean age: 58 years, 72% female) treated with the DED for 122 aneurysms at a single center between 2017 and 2023 was retrospectively analyzed for major (change in National Institutes of Health Stroke Scale [NIHSS] score ≥ 4 points) and minor (change in NIHSS score < 4 points) neurological events, procedural morbidity (increase of at least one point on the modified Rankin Scale), and angiographic results. RESULTS: There were 14 (11%) recurrent aneurysms, 15 (12%) ruptured aneurysms, 26 (21%) posterior circulation aneurysms and 16 (13%) fusiform or dissecting aneurysms. Device deployment failed in 1 case (1%). Procedure-related symptomatic procedural complications consisted of 2 (2%) major events (1 major stroke and 1 vessel perforation with intracranial hemorrhage and infarction) and 6 minor events (6 minor strokes). Procedural morbidity was 5%. There were no late ischemic or hemorrhagic events during follow-up. Complete and favorable aneurysm occlusion was achieved in 54% (40/74) and 62% (46/74) at a mean of 5 months, 71% (27/38) and 87% (33/38) at a mean of 12 months, and 76% (25/33) and 97% (32/33) at a mean of 35 months, respectively. CONCLUSION: The results demonstrate progressive aneurysm occlusion beyond 12 months after DED implantation with an almost 100% favorable occlusion rate. Procedural morbidity was low and there were no late complications.

9.
Magn Reson Imaging ; 112: 27-37, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38599503

RESUMO

BACKGROUND AND PURPOSE: Long acquisition times limit the feasibility of established non-contrast-enhanced MRA (non-CE-MRA) techniques. The purpose of this study was to evaluate a highly accelerated flow-independent sequence (Relaxation-Enhanced Angiography without Contrast and Triggering [REACT]) for imaging of the extracranial arteries in acute ischemic stroke (AIS). MATERIALS AND METHODS: Compressed SENSE (CS) accelerated (factor 7) 3D isotropic REACT (fixed scan time: 01:22 min, reconstructed voxel size 0.625 × 0.625 × 0.75 mm3) and CE-MRA (CS factor 6, scan time: 1:08 min, reconstructed voxel size 0.5 mm3) were acquired in 76 AIS patients (69.4 ± 14.3 years, 33 females) at 3 Tesla. Two radiologists assessed scans for the presence of internal carotid artery (ICA) stenosis and stated their diagnostic confidence using a 5-point scale (5 = excellent). Vessel quality of cervical arteries as well as the impact of artifacts and image noise were scored on 5-point scales (5 = excellent/none). Apparent signal- and contrast-to-noise ratios (aSNR/aCNR) were measured for the common carotid artery (CCA) and ICA (C1-segment). RESULTS: REACT provided a sensitivity of 88.5% and specificity of 100% for clinically relevant (≥50%) ICA stenosis with substantial concordance to CE-MRA regarding stenosis grading (Cohen's kappa 0.778) and similar diagnostic confidence (REACT: mean 4.5 ± 0.4 vs. CE-MRA: 4.5 ± 0.6; P = 0.674). Presence of artifacts (3.6 ± 0.5 vs. 3.5 ± 0.7; P = 0.985) and vessel quality (all segments: 3.6 ± 0.7 vs. 3.8 ± 0.7; P = 0.004) were comparable between both techniques with REACT showing higher scores at the CCA (4.3 ± 0.6 vs. 3.8 ± 0.9; P < 0.001) and CE-MRA at V2- (3.3 ± 0.5 vs. 3.9 ± 0.8; P < 0.001) and V3-segments (3.3 ± 0.5 vs. 4.0 ± 0.8; P < 0.001). For all vessels, REACT showed a lower impact of image noise (3.8 ± 0.6 vs. 3.6 ± 0.7; P = 0.024) while yielding higher aSNR (52.5 ± 15.1 vs. 37.9 ± 12.5; P < 0.001) and aCNR (49.4 ± 15.0 vs. 34.7 ± 12.3; P < 0.001) for all vessels combined. CONCLUSIONS: In patients with acute ischemic stroke, highly accelerated REACT provides an accurate detection of ICA stenosis with vessel quality and scan time comparable to CE-MRA.


Assuntos
AVC Isquêmico , Angiografia por Ressonância Magnética , Humanos , Feminino , Masculino , Angiografia por Ressonância Magnética/métodos , Idoso , AVC Isquêmico/diagnóstico por imagem , Pessoa de Meia-Idade , Pescoço/diagnóstico por imagem , Pescoço/irrigação sanguínea , Meios de Contraste , Idoso de 80 Anos ou mais , Razão Sinal-Ruído , Processamento de Imagem Assistida por Computador/métodos , Artefatos , Imageamento Tridimensional/métodos , Reprodutibilidade dos Testes , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos
10.
Neuroradiol J ; 37(3): 336-341, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38490750

RESUMO

OBJECTIVES: Glioses appear as hypodense lesions in non-contrast CT examinations of the head. Photon counting CT (PCCT) enables the calculation of virtual monoenergetic images (VMI). The aim of this study is to investigate in which VMI hypodense gliotic lesions can be delineated best. MATERIALS AND METHODS: 35 patients with an MRI-confirmed gliotic lesion and a non-contrast PCCT of the head were retrospectively included. All available VMI from 40 keV to 190 keV were calculated. In a quantitative analysis, conventional image quality parameters were calculated, in particular the contrast-to-noise ratio (CNR) of the hypodense lesion compared to the white matter. In a qualitative analysis, selected VMI were rated by experienced radiologists. RESULTS: The absolute maximum of CNR was 8.12 ± 5.64 in the VMI 134 keV, in post hoc testing, there were significant differences in comparison to VMI with keV ≤110 and keV ≥180 (corrected p < .05). In the qualitative analysis, there were only very slight differences in the rating of the VMI with 66 keV, 80 keV, 100 keV, and 134 keV with overall low agreement between the readers. CONCLUSIONS: The quantitative superiority of VMI 134 keV for the delineation of hypodense gliotic lesions did not translate into a superiority in the qualitative analysis. Therefore, it remains uncertain if the reconstruction of a high keV VMIs for the detection of hypodense gliotic lesions is useful in everyday clinical practice. However, more studies, are necessary to further assess this issue.


Assuntos
Tomografia Computadorizada por Raios X , Humanos , Feminino , Masculino , Estudos Retrospectivos , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X/métodos , Idoso , Adulto , Idoso de 80 Anos ou mais , Imageamento por Ressonância Magnética/métodos , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/patologia , Fótons
11.
Heliyon ; 10(6): e27636, 2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38509988

RESUMO

Rationale and objectives: Coronary computed tomography angiography (CCTA) is becoming increasingly important for the diagnostic workup of coronary artery disease, nevertheless, imaging of in-stent stenosis remains challenging. For the first time, spectral imaging in Ultra High Resolution (UHR) is now possible in clinically available photon counting CT. The aim of this work is to determine the optimal virtual monoenergetic image (VMI) for imaging in-stent stenoses in cardiac stents. Materials and methods: 6 stents with inserted hypodense stenoses were scanned in an established phantom in UHR mode. Images were reconstructed with 3 different kernels for spectral data (Qr56, Qr64, Qr72) with varying levels of sharpness. Based on region of interest (ROI) measurements image quality parameters including contrast-to-noise ratio (CNR) were analyzed for all available VMI (40 keV-190 keV). Finally, based on quantitative results and VMI used in clinical routine, a set of VMI was included in a qualitative reading. Results: CNR showed significant variations across different keV levels (p < 0.001). Due to reduced noise there was a focal maximum in the VMI around 65 keV. The peak values were observed for kernel Qr56 at 116 keV with 19.47 ± 8.67, for kernel Qr64 at 114 keV with 13.56 ± 6.58, and for kernel Qr72 at 106 keV with 12.19 ± 3.25. However, in the qualitative evaluation the VMI with lower keV (55 keV) performed best. Conclusions: Based on these experimental results, a photon counting CCTA in UHR with stents should be reconstructed with the Qr72 kernel for the assessment of in-stent stenoses, and a VMI 55 keV should be computed for the evaluation.

12.
Radiology ; 310(3): e230545, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38530174

RESUMO

Background Coronary artery calcium scoring (CACS) for coronary artery disease requires true noncontrast (TNC) CT alongside contrast-enhanced coronary CT angiography (CCTA). Photon-counting CT provides an algorithm (PureCalcium) for reconstructing virtual noncontrast images from CCTA specifically for CACS. Purpose To assess CACS differences based on PureCalcium images derived from contrast-enhanced photon-counting CCTA compared with TNC images and evaluate the impact of these differences on the clinically relevant classification of patients into plaque burden groups. Materials and Methods Photon-counting CCTA images acquired between August 2022 and May 2023 were retrospectively identified. Agatston scores were derived from both TNC and PureCalcium images and tested for differences with use of the Wilcoxon signed-rank test. The agreement was assessed with use of equivalence tests, Bland-Altman analysis, and intraclass correlation coefficient. Plaque burden groups were established based on Agatston scores, and agreement was evaluated using weighted Cohen kappa. The dose-length product was analyzed. Results Among 170 patients (mean age, 63 years ± 13 [SD]; 92 male), 111 had Agatston scores higher than 0. Median Agatston scores did not differ between TNC and PureCalcium images (4.8 [IQR, 0-84.4; range, 0.0-2151.8] vs 2.7 [IQR, 0-90.7; range, 0.0-2377.1]; P = .99), with strong correlation (intraclass correlation coefficient, 0.98 [95% CI: 0.97, 0.99]). The equivalence test was inconclusive, with a 95% CI of 0.90, 1.19. Bland-Altman analysis showed wide repeatability limits, indicating low agreement between the two scores. With use of the PureCalcium algorithm, 125 of 170 patients (74%) were correctly classified into plaque burden groups (excellent agreement, κ = 0.88). Patients without plaque burden were misclassified at higher than normal rates (P < .001). TNC image acquisition contributed a mean of 19.7% ± 8.8 of the radiation dose of the entire examination. Conclusion PureCalcium images show potential to replace TNC images for measuring Agatston scores, thereby reducing radiation dose in CCTA. There was strong correlation in calcium scores between TNC and PureCalcium, but limited agreement. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Sakuma in this issue.


Assuntos
Cálcio , Angiografia por Tomografia Computadorizada , Humanos , Masculino , Pessoa de Meia-Idade , Vasos Coronários/diagnóstico por imagem , Estudos Retrospectivos , Angiografia Coronária , Tomografia Computadorizada por Raios X
13.
Acad Radiol ; 31(7): 2715-2724, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38368163

RESUMO

RATIONALE AND OBJECTIVES: Accurate and efficient estimation of patient height and weight is crucial to ensure patient safety and optimize the quality of magnetic resonance imaging (MRI) procedures. Several height and weight estimation methods have been proposed for use in adult patient management, but none is widely established. Estimation by the medical technologists for radiology (MTR) based on personal experience remains to be the most common method. This study aimed to compare a novel deep learning (DL)-based 3-dimensional (3D) camera estimation method to MTR staff in terms of estimation accuracy. METHODS: A retrospective study was conducted to compare the accuracy of height and weight estimation with a DL-based 3D camera algorithm to the accuracy of height and weight estimation by the MTR. Depth images of the patients were captured during the regular imaging workflow on a low field 0.55 T MRI scanner (MAGNETOM Free.Max, Siemens Healthineers, Erlangen, Germany) and then processed retrospectively. Depth images of a total of 161 patients were used to validate the accuracy of the height and weight estimation algorithm. The accuracy of each estimation method was evaluated by computing the proportions of the estimates within 5% and 15% of actual height (PH05, PH15) and within 10% and 20% of actual weight (PW10, PW20). An acceptable accuracy for height estimation was predetermined to be PH05 = 95% and PH15 = 99% and an acceptable accuracy for weight estimation was predetermined to be PW10 = 70% and PW20 = 95%. The bias in height and weight estimation was measured by the mean absolute percentage error (MAPE). RESULTS: The retrospective study included 161 adult patients. For 148/161 patients complying with inclusion criteria, DL-based 3D camera algorithm outperformed the MTR in estimating the patient's height and weight in term of accuracy (3D camera: PH05 =98.6%, PH15 =100%, PW10 =85.1%, PW20 =95.9%; MTR: PH05 =92.5%, PH15 =100%, PW10 =75.0%, PW20 =93.2%). MTR had a slightly higher bias in their estimates compared to the DL-based 3D camera algorithm (3D camera: MAPE height=1.8%, MAPE weight=5.6%, MTR: MAPE height=2.2%, MAPE weight=7.5%) CONCLUSION: This study has demonstrated that the estimation of the patient's height and weight by a DL-based 3D camera algorithm is accurate and robust. It has the potential to complement the regular MRI workflows, by providing further automation during patient registration.


Assuntos
Estatura , Peso Corporal , Aprendizado Profundo , Estudos de Viabilidade , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Estudos Retrospectivos , Masculino , Feminino , Imageamento Tridimensional/métodos , Adulto , Pessoa de Meia-Idade , Algoritmos , Idoso
14.
Leuk Lymphoma ; 65(6): 825-832, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38384127

RESUMO

Studies regarding the influence of body composition parameters as predictors on overall survival (OS) in patients with multiple myeloma (MM) are scarce. OS and progression-free survival (PFS) were retrospectively assessed in 129 patients with MM undergoing autologous stem cell transplantation (ASCT) after a follow-up of 2 years. A computed tomography (CT) based semi-automated assessment of body composition was performed. No statistically significant differences were noted in 2-year OS, PFS, or post-transplant adverse events in the body composition groups of subcutaneous adipose tissue (SAT) (low vs. high-SAT), visceral adipose tissue (VAT) (low vs. high-VAT), visceral-to-subcutaneous fat ratio (VSR) (low vs. high VSR), and sarcopenia in terms of skeletal muscle index (SMI) (non-sarcopenic vs. sarcopenic). In conclusion, adipose and muscle tissue do not limit OS or affect the PFS in patients with MM undergoing ASCT.


Assuntos
Composição Corporal , Transplante de Células-Tronco Hematopoéticas , Mieloma Múltiplo , Transplante Autólogo , Humanos , Mieloma Múltiplo/terapia , Mieloma Múltiplo/mortalidade , Mieloma Múltiplo/diagnóstico , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Transplante de Células-Tronco Hematopoéticas/efeitos adversos , Transplante de Células-Tronco Hematopoéticas/métodos , Estudos Retrospectivos , Prognóstico , Adulto , Sarcopenia/etiologia , Sarcopenia/diagnóstico , Seguimentos , Tomografia Computadorizada por Raios X , Gordura Intra-Abdominal/diagnóstico por imagem , Resultado do Tratamento
15.
Acad Radiol ; 2024 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-38418345

RESUMO

RATIONALE AND OBJECTIVES: Common computed tomography (CT) investigation plays a limited role in characterizing and assessing the response of rectal cancer (RC) to neoadjuvant radiochemotherapy (NARC). Photon counting computed tomography (PCCT) improves the imaging quality and can provide multiparametric spectral image information including iodine concentration (IC). Our purpose was to analyze associations between IC and histopathology in RC and to evaluate the role of IC in response prediction to NARC. MATERIALS AND METHODS: Overall, 41 patients were included into the study, 14 women and 27 men, mean age, 65.5 years. PCCT in a portal venous phase of the abdomen was performed. In every case, a polygonal region of interest (ROI) was manually drawn on iodine maps. Normalized IC (NIC) was also calculated. Tumor stage, grade, lymphovascular invasion, circumferential resection margin, and tumor markers were analyzed. Tumor regression grade (absence/presence of tumor cells) after NARC was analyzed. NIC values in groups were compared to Mann-Whitney-U tests. Sensitivity, specificity, and area under the curve values were calculated. Intraclass correlation coefficient (ICC) was calculated. RESULTS: ICC was 0.93, 95%CI= (0.88; 0.96). Tumors with lymphovascular invasion showed higher NIC values in comparison to those without (p = 0.04). Tumors with response grade 2-4 showed higher pretreatment NIC values in comparison to lesions with response grade 0-1 (p = 0.01). A NIC value of 0.36 and higher can predict response grade 2-4 (sensitivity, 73.9%; specificity, 91.7%; area under the curve, 0.85). CONCLUSION: NIC values showed an excellent interreader agreement in RC. NIC can predict treatment response to NARC.

16.
Nutrition ; 120: 112327, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38341908

RESUMO

OBJECTIVES: Body composition on computed tomography can predict prognosis in patients with COVID-19. The reported data are based on small retrospective studies. The aim of the present study was to analyze the prognostic relevance of skeletal muscle parameter derived from chest computed tomography for prediction of 30-d mortality in patients with COVID-19 in a multicenter setting. METHODS: The clinical databases of three centers were screened for patients with COVID-19 between 2020 and 2022. Overall, 447 patients (142 female; 31.7%) were included into the study. The mean age at the time of computed tomography acquisition was 63.8 ± 14.7 y and median age was 65 y. Skeletal muscle area and skeletal muscle density were defined on level T12 of the chest. RESULTS: Overall, 118 patients (26.3%) died within the 30-d observation period. Of the patient sample, 255 patients (57.0%) were admitted to an intensive care unit and 122 patients needed mechanical ventilation (27.3%). The mean skeletal muscle area of all patients was 96.1 ± 27.2 cm² (range = 23.2-200.7 cm²). For skeletal muscle density, the mean was 24.3 ± 11.1 Hounsfield units (range = -5.6 to 55.8 Hounsfield units). In survivors, the mean skeletal muscle density was higher compared with the lethal cases (mean 25.8 ± 11.2 versus 20.1 ± 9.6; P < 0.0001). Presence of myosteatosis was independently associated with 30-d mortality: odds ratio = 2.72 (95% CI, 1.71-4.32); P = 0.0001. CONCLUSIONS: Myosteatosis is strongly associated with 30-d mortality in patients COVID-19. Patients with COVID-19 with myosteatosis should be considered a risk group.


Assuntos
COVID-19 , Sarcopenia , Idoso , Feminino , Humanos , Composição Corporal , COVID-19/complicações , Músculo Esquelético/diagnóstico por imagem , Músculo Esquelético/patologia , Estudos Retrospectivos , Fatores de Risco , Sarcopenia/complicações , Sarcopenia/diagnóstico por imagem , Sarcopenia/patologia , Masculino , Pessoa de Meia-Idade
17.
Eur J Radiol ; 173: 111374, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38422607

RESUMO

PURPOSE OF THE STUDY: The aim of the study was to identify differences in the tumor conspicuity of pancreatic adenocarcinomas in different monoenergetic or polyenergetic reconstructions and contrast phases in photon-counting CT (PCCT). MATERIAL AND METHODS: 34 patients were retrospectively enrolled in this study. Quantitative image analysis was performed with region of interest (ROI) measurements in different monoenergetic levels ranging from 40 up to 70 keV (5-point steps) and polyenergetic series. Tumor-parenchyma attenuation differences and contrast-to-noise-ratio (CNR) were calculated. A qualitative image analysis was accomplished by 4 radiologists using a 5-point Likert scale (1 = "not recognizable" up to 5 = "easy recognizable"). Differences between groups were evaluated for statistical significance using the Friedman test and in case of significant differences pair-wise post-hoc testing with Bonferroni correction was applied. RESULTS: Tumor-parenchyma attenuation difference was significantly different between the different image reconstructions for both arterial- and portal-venous-phase-images (p < 0.001). Tumor-parenchyma attenuation difference was significantly higher on arterial-phase-images at mono40keV compared to polyenergetic images (p < 0.001) and mono55keV images or higher (p < 0.001). For portal-venous-phase-images tumor-parenchyma attenuation difference was significantly higher on mono40keV images compared to polyenergetic images (p < 0.001) and mono50keV images (p = 0.03) or higher (p < 0.001). The same trend was seen for CNR. Tumor conspicuity was rated best on mono40keV images with 4.3 ± 0.9 for arterial-phase-images and 4.3 ± 1.1 for portal-venous-phase-images. In contrast, overall image quality was rated best on polyenergetic-images with 4.8 ± 0.5 for arterial-phase-images and 4.7 ± 0.6 for portal-venous-phase-images. CONCLUSION: Low keV virtual monoenergetic images significantly improve the tumor conspicuity of pancreatic adenocarcinomas in PCCT based on quantitative and qualitative results. On the other hand, readers prefer polyenergetic images for overall image quality.


Assuntos
Adenocarcinoma , Neoplasias Pancreáticas , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Humanos , Estudos Retrospectivos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Neoplasias Pancreáticas/diagnóstico por imagem , Adenocarcinoma/diagnóstico por imagem , Razão Sinal-Ruído , Interpretação de Imagem Radiográfica Assistida por Computador
18.
Neuroradiology ; 66(5): 729-736, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38411902

RESUMO

PURPOSE: To determine the optimal virtual monoenergetic image (VMI) for detecting and assessing intracranial hemorrhage in unenhanced photon counting CT of the head based on the evaluation of quantitative and qualitative image quality parameters. METHODS: Sixty-three patients with acute intracranial hemorrhage and unenhanced CT of the head were retrospectively included. In these patients, 35 intraparenchymal, 39 intraventricular, 30 subarachnoidal, and 43 subdural hemorrhages were selected. VMIs were reconstructed using all available monoenergetic reconstruction levels (40-190 keV). Multiple regions of interest measurements were used for evaluation of the overall image quality, and signal, noise, signal-to-noise-ratio (SNR), and contrast-to-noise-ratio (CNR) of intracranial hemorrhage. Based on the results of the quantitative analysis, specific VMIs were rated by five radiologists on a 5-point Likert scale. RESULTS: Signal, noise, SNR, and CNR differed significantly between different VMIs (p < 0.001). Maximum CNR for intracranial hemorrhage was reached in VMI with keV levels > 120 keV (intraparenchymal 143 keV, intraventricular 164 keV, subarachnoidal 124 keV, and subdural hemorrhage 133 keV). In reading, no relevant superiority in the detection of hemorrhage could be demonstrated using VMIs above 66 keV. CONCLUSION: For the detection of hemorrhage in unenhanced CT of the head, the quantitative analysis of the present study on photon counting CT is generally consistent with the findings from dual-energy CT, suggesting keV levels just above 120 keV and higher depending on the location of the hemorrhage. However, on the basis of the qualitative analyses, no reliable statement can yet be made as to whether an additional VMI with higher keV is truly beneficial in everyday clinical practice.


Assuntos
Interpretação de Imagem Radiográfica Assistida por Computador , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Humanos , Estudos Retrospectivos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Hemorragias Intracranianas/diagnóstico por imagem , Razão Sinal-Ruído
20.
Acad Radiol ; 31(2): 686-692, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37393176

RESUMO

RATIONALE AND OBJECTIVES: To evaluate the potential to reduce the amount of iodinated contrast media (CM) for computer tomographic pulmonary angiography (CTPA) with a novel photon-counting-detector CT (PCCT). MATERIALS AND METHODS: Overall, 105 patients referred for CTPA were retrospectively included in this study. CTPA was performed using bolus tracking and high-pitch dual-source scanning (FLASH mode) on a novel PCCT (Naeotom Alpha, Siemens Healthineers). CM (Accupaque 300, GE Healthcare) dose was lowered stepwise following the introduction of the new CT scanner. Thus, patients could be divided into 3 groups as follows: group 1, n = 29, 35 ml of CM; group 2, n = 62, 45 ml of CM and group 3, n = 14, 60 ml of CM. Four readers independently assessed the image quality (Likert-scale 1-5) and adequate assessment of the segmental pulmonary arteries. Additionally, the pulmonary arterial contrast opacification was measured. RESULTS: The subjective image quality was rated highest in group 1 with 4.6 compared to 4.5 (group 2) and 4.1 (group 3) with a significant difference between groups 1 and 3 (p < 0.001) and between groups 2 and 3 (p = 0.003). In all groups, almost all segmental pulmonary arteries could be assessed adequately without significant differences (18.5 vs. 18.7 vs. 18.4). Mean attenuation in the pulmonary trunk did not differ significantly between groups 321 ± 92 HU versus 345 ± 93 HU versus 347 ± 88 HU (p = 0.69). CONCLUSION: Significant CM dose reduction is possible without a reduction in image quality. PCCT enables diagnostic CTPA with 35 ml of CM.


Assuntos
Meios de Contraste , Embolia Pulmonar , Humanos , Embolia Pulmonar/diagnóstico por imagem , Estudos Retrospectivos , Artéria Pulmonar/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Angiografia/métodos , Angiografia por Tomografia Computadorizada/métodos , Doses de Radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA