Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Materials (Basel) ; 13(9)2020 04 25.
Artigo em Inglês | MEDLINE | ID: mdl-32344894

RESUMO

In recent years, Zirconia-reinforced Lithium Silicate ceramic (ZLS), combining lithium-silicate and zirconia features, has shown to have excellent mechanical and aesthetic characteristics. Thus, the aim of this study was to compare the fracture strength of ZLS single crowns cemented with two different cementation techniques. Twenty crowns were realised and cemented on teeth replicas achieved from an extracted premolar human tooth. The samples were divided into two groups of 10 specimens each, Glass-ionomeric cement (GIC) group and Self-Adhesive Resin Cement (ARC) group. The mechanical test was performed using a universal testing machine. The specimens were then evaluated with a scanning electron microscope (SEM) to identify for all crowns and related abutments the pattern of fracture after the breaking point. The data obtained were statistically analysed. The mean fracture toughness values and standard deviations (±SD) were 2227 ± 382 N and 3712 ± 319 N respectively for GIC and ARC groups. In fact, t-test showed a statistically significant difference between the two groups (p < 0.001). Moreover, the SEM results demonstrated portions of abutments still attached to the crown fragments in the ARC group, whilst these were not present in the GIC group. Within the limitations of this study, these results suggest the use of adhesive cementation for ZLS crowns, which significantly increase the compressive strength of ZLS restorations compared to GIC.

2.
Stem Cell Res Ther ; 9(1): 104, 2018 04 13.
Artigo em Inglês | MEDLINE | ID: mdl-29653587

RESUMO

BACKGROUND: The role of bone tissue engineering in the field of regenerative medicine has been a main research topic over the past few years. There has been much interest in the use of three-dimensional (3D) engineered scaffolds (PLA) complexed with human gingival mesenchymal stem cells (hGMSCs) as a new therapeutic strategy to improve bone tissue regeneration. These devices can mimic a more favorable endogenous microenvironment for cells in vivo by providing 3D substrates which are able to support cell survival, proliferation and differentiation. The present study evaluated the in vitro and in vivo capability of bone defect regeneration of 3D PLA, hGMSCs, extracellular vesicles (EVs), or polyethyleneimine (PEI)-engineered EVs (PEI-EVs) in the following experimental groups: 3D-PLA, 3D-PLA + hGMSCs, 3D-PLA + EVs, 3D-PLA + EVs + hGMSCs, 3D-PLA + PEI-EVs, 3D-PLA + PEI-EVs + hGMSCs. METHODS: The structural parameters of the scaffold were evaluated using both scanning electron microscopy and nondestructive microcomputed tomography. Nanotopographic surface features were investigated by means of atomic force microscopy. Scaffolds showed a statistically significant mass loss along the 112-day evaluation. RESULTS: Our in vitro results revealed that both 3D-PLA + EVs + hGMSCs and 3D-PLA + PEI-EVs + hGMSCs showed no cytotoxicity. However, 3D-PLA + PEI-EVs + hGMSCs exhibited greater osteogenic inductivity as revealed by morphological evaluation and transcriptomic analysis performed by next-generation sequencing (NGS). In addition, in vivo results showed that 3D-PLA + PEI-EVs + hGMSCs and 3D-PLA + PEI-EVs scaffolds implanted in rats subjected to cortical calvaria bone tissue damage were able to improve bone healing by showing better osteogenic properties. These results were supported also by computed tomography evaluation that revealed the repair of bone calvaria damage. CONCLUSION: The re-establishing of the integrity of the bone lesions could be a promising strategy in the treatment of accidental or surgery trauma, especially for cranial bones.


Assuntos
Vesículas Extracelulares/metabolismo , Gengiva/metabolismo , Células-Tronco Mesenquimais/metabolismo , Microscopia de Força Atômica/métodos , Alicerces Teciduais/química , Animais , Regeneração Óssea , Humanos , Masculino , Ratos , Ratos Wistar
3.
J Biomed Mater Res A ; 106(1): 126-137, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28879677

RESUMO

The combined approach of mesenchymal stem cells (MSCs) and scaffolds has been proposed as a potential therapeutic tool for the treatment of neurodegenerative diseases. Indeed, even if MSCs can promote neuronal regeneration, replacing lost neurons or secreting neurotrophic factors, many limitations still exist for their application in regenerative medicine, including the low survival and differentiation rate. The scaffolds, by mimicking the endogenous microenvironment, have shown to promote cell survival, proliferation, and differentiation. In this work, gingival mesenchymal stem cells (GMSCs), isolated from healthy donors, were expanded in vitro, by culturing them adherent in plastic dishes (CTR-GMSCs) or on a poly(lactic acid) scaffold (SC-GMSCs). In order to evaluate the survival and the neurogenic differentiation potential, we performed a comparative transcriptomic analysis between CTR-GMSCs and SC-GMSCs by next generation sequencing. We found that SC-GMSCs showed an increased expression of neurogenic and prosurvival genes. In particular, genes involved in neurotrophin signaling and PI3K/Akt pathways were upregulated. On the contrary, proapoptotic and negative regulator of neuronal growth genes were downregulated. Moreover, nestin and GAP-43 protein levels increased in SC-GMSCs, confirming the neurogenic commitment of these cells. In conclusion, the scaffold, providing a trophic support for MSCs, may promote GMSCs differentiation toward a neuronal phenotype and survival. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 106A: 126-137, 2018.


Assuntos
Gengiva/citologia , Células-Tronco Mesenquimais/citologia , Regeneração Nervosa , Neurônios/citologia , Alicerces Teciduais , Transcriptoma , Apoptose/genética , Diferenciação Celular/genética , Gengiva/metabolismo , Humanos , Células-Tronco Mesenquimais/metabolismo , Fatores de Crescimento Neural/genética , Neurogênese/genética , Neurônios/metabolismo , Fosfatidilinositol 3-Quinases/genética , Poliésteres/química , Cultura Primária de Células
5.
J Prosthodont ; 25(8): 629-633, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26436677

RESUMO

PURPOSE: To clinically evaluate the amount of contact wear generated between full-arch monolithic zirconia implant-supported restorations and natural or composite antagonists, over a 1-year period. MATERIALS AND METHODS: Forty-seven teeth from clinically functional, full-arch monolithic zirconia screw-retained implant prostheses (FDPs) and their antagonists were investigated. The first group ("Zirconia-E") was opposed to natural teeth ("Enamel"), whereas the other one ("Zirconia-CR") was opposed to nano-hybrid composite teeth ("Composite Resin"). Replicas of the restorations and their antagonists were obtained immediately after delivery (T0 ) and after 1 year of clinical service (T1 ). Each tooth surface was individually evaluated three-dimensionally by software to quantify the vertical distance between the two scans (Hausdorff distance), which was considered as contact wear. Data obtained for each arch were subjected to one-way ANOVA test and a post hoc analysis (Tukey's test) at a 5% level of significance. Furthermore, the influence of the location of the teeth (anterior or posterior) was analyzed. Minimum post hoc statistical power between statistically different groups was 99.6%. RESULTS: Mean values were 63 ± 23 µm for Zirconia-E, 76 ± 29 µm for enamel, 70 ± 38 µm for composite resin; Zirconia-CR had a mean value of 19 ± 4 µm and significantly differed from the other groups. Contact wear between anterior and posterior teeth differed significantly only in the composite resin arch, with a mean of 39 ± 22 µm for anterior teeth versus 101 ± 19 µm for posterior ones. CONCLUSIONS: Within the limitations of this preliminary evaluation, monolithic zirconia full-arch rehabilitations induced a clinically acceptable wear on natural and composite antagonists over a 1-year period; they might be considered a viable solution for implant-supported rehabilitations.


Assuntos
Resinas Compostas , Implantes Dentários , Zircônio , Materiais Dentários , Humanos , Desgaste dos Dentes
6.
J Prosthet Dent ; 113(2): 108-13, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25438741

RESUMO

STATEMENT OF THE PROBLEM: Polyvinyl siloxane materials of various consistencies have been tested to reduce defects commonly associated with different definitive impression techniques. PURPOSE: The purpose of this in vitro study was to compare the number of visible defects within the surface of a new 3-phase, 2-step impression injection technique with the number found in the monophase and in the conventional 2-phase, 1-step and 2-phase, 2-step impression techniques. MATERIAL AND METHODS: Two complete crown abutment preparations were impressed 10 times for each of these 4 techniques, which gave 20 abutment impressions for each group. The 3-phase, 2-step impression--injection technique included extra-light--body impression material added for the impression and injected after reinsertion. After the removal of all of these impressions, an examiner counted the number of open voids and bubble-like enclosed voids visible to the naked eye at a working distance of approximately 150 mm. Only the defects in the area of the prepared abutments were included in the assessment. RESULTS: The frequency of defects ranged from 100% of the impressions in the monophase group to 5% with the new 3-phase, 2-step impression injection technique. No statistical differences were seen between the two 2-phase (1-step and 2-step) impression techniques, although there were numerically fewer impressions with defects with 2 steps (45%) than with 1 step (55%). The 3-phase, 2-step impression injection technique had the greatest accuracy, with fewer specimens with defects (5%) than with either of the 2-phase techniques, although these differences did not reach statistical significance. CONCLUSIONS: The 3-phase, 2-step impression injection technique provides improved defect-free reproduction of detail, showing fewer defects than other impression techniques.


Assuntos
Materiais para Moldagem Odontológica/química , Técnica de Moldagem Odontológica , Polivinil/química , Siloxanas/química , Coroas , Dente Suporte , Técnica de Moldagem Odontológica/instrumentação , Elastômeros/química , Humanos , Teste de Materiais , Polimerização , Porosidade , Propriedades de Superfície , Fatores de Tempo , Preparo Prostodôntico do Dente/métodos , Viscosidade
7.
Quintessence Int ; 45(9): 757-62, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25126645

RESUMO

OBJECTIVE: To describe the successful use of biphasic calcium sulfate for improving the buccal plate thickness in an immediate postextraction implant, and its fi nal restoration with custom lithium disilicate abutment and veneer. SUMMARY: A hopeless lateral incisor was replaced with an immediate postextraction implant in conjunction with a buccal plate augmentation based on biphasic calcium sulfate. Satisfactory soft tissue height and quality were maintained following healing. The fi nal restoration managed the severely reduced prosthetic space due to deep bite, and allowed an adhesive luting procedure.


Assuntos
Bochecha/cirurgia , Dente Suporte , Implantes Dentários , Porcelana Dentária , Facetas Dentárias , Feminino , Humanos , Pessoa de Meia-Idade
8.
Eur J Esthet Dent ; 7(1): 48-60, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22319764

RESUMO

Many treatment options are currently available for single tooth replacement, such as metal-ceramic, all-ceramic, direct or indirect fiber-reinforced composite fixed dental prostheses (FDPs) or implants. Inlay-retained FDPs could be indicated especially when adjacent teeth have preexisting restorations and where implant placement is not possible or not indicated. In such cases, indication of both metal-ceramic and fiber-reinforced composite FDPs has certain disadvantages. This paper describes the use of all-ceramic inlay-retained FDPs with zirconia frameworks, veneered with a press-on technique. The retainer margins were made of pressed ceramic to make adhesive luting possible. In deep cavities, a full contour press-on ceramic all around the retainers increased the available surface area for the adhesive approach.


Assuntos
Materiais Dentários/química , Planejamento de Dentadura , Encaixe de Precisão de Dentadura , Retenção de Dentadura , Prótese Parcial Fixa , Restaurações Intracoronárias , Zircônio/química , Cimentação/métodos , Desenho Assistido por Computador , Dente Suporte , Oclusão Dentária , Porcelana Dentária/química , Facetas Dentárias , Humanos , Cimentos de Resina/química , Preparo Prostodôntico do Dente
9.
J Dent ; 2011 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-22027653

RESUMO

OBJECTIVES: The aim of this clinical trial was to test the accuracy of single all-ceramic zirconia crowns resulting from digital intraoral impressions with active wavefront sampling technology by measuring the marginal and internal fits of the crowns. MATERIALS AND METHODS: Thirty-seven teeth (24 anterior and 13 posterior) in fifteen patients were restored with single zirconia-ceramic crowns (Lava/Lava Ceram; 3M ESPE) generated from a digital intraoral scanner (Lava Chairside Oral Scanner; 3M ESPE). Before definitive insertion, silicone replicas were produced for all 37 crowns. The sample was cut in four sections; each section was evaluated in four points: marginal gap, mid-axial wall, axio-occlusal edge and centro-occlusal. A total of 592 measurements (148 for each evaluation point) was examined using stereomicroscopy with a magnification of 50×. The Mann-Whitney U test was used to evaluate whether there were differences between anterior and posterior values (alpha=0.05). RESULTS: The mean values for each point were: 48.65µm (SD 29.45µm) for the marginal gap, 112.25µm (SD 55.54µm) at the mid-axial wall, 137.81µm (SD 71.31µm) at the axio-occlusal edge of the abutments, and 157.25µm (SD 75.51µm) at the centro-occlusal location. No statistical differences were found between the anterior and posterior group for each point (p-values: P1=0.39; P2=0.38; P3=0.07; P4=0.30). CONCLUSIONS: The marginal and internal fitting values obtained were within literature agreed as clinically acceptable for both anterior and posterior teeth. CLINICAL RELEVANCE: Single crown restorations obtained using digital intraoral impressions based on active wavefront sampling technology presented enough accuracy to be used as an alternative to the conventional impression techniques.

10.
Int J Comput Dent ; 14(2): 147-53, 2011.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-21877381

RESUMO

The way we collect, store, and share dental records of our patients is rapidly becoming digital. Many programs have been designed to run on a single computer or local network to handle various tasks, so selecting a system can be complex; it can require high acquisition costs, update fees, and installation difficulties. The purpose of this article is to explain the architecture, characteristics, and advantages related to Web-based Management Software. In particular, this article describes the first Web-based Electronic Medical Record (DocSapiens.com), which is able to view and edit DICOM files directly online.


Assuntos
Informática Odontológica , Internet , Sistemas de Informação Administrativa , Sistemas On-Line , Registros Odontológicos , Humanos , Software
11.
J Can Dent Assoc ; 77: b86, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21736862

RESUMO

Currently, there are many options for single-tooth replacement: metal-ceramic, all-ceramic, direct or indirect fibre-reinforced composite fixed dental prostheses (FDPs) or implants. Inlay-retained FDPs may especially be indicated when adjacent teeth have been previously restored and when implant placement is not possible or not indicated. In such cases, both metal-ceramic and fibre-reinforced composite FDPs have certain disadvantages. In this paper, we describe the use of all-ceramic inlay-retained FDPs with zirconia frameworks, veneered using a press-on technique.


Assuntos
Materiais Dentários/química , Porcelana Dentária/química , Planejamento de Dentadura , Prótese Parcial Fixa , Restaurações Intracoronárias , Ítrio/química , Zircônio/química , Resinas Compostas/química , Dente Suporte , Facetas Dentárias , Encaixe de Precisão de Dentadura , Retenção de Dentadura , Humanos , Cimentos de Resina/química , Preparo Prostodôntico do Dente
12.
J Prosthodont ; 20(2): 97-100, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21284761

RESUMO

PURPOSE: This study evaluated the bond strength between resin cement and Y-TZP ceramic (Yttrium-stabilized Tetragonal Zirconia Polycrystalline) submitted to different surface conditionings. MATERIALS AND METHODS: Fifty Y-TZP ceramic discs (Ø= 10 mm) were allocated into five groups: Gr1 (control)-no conditioning; Gr2-tribochemical silica coating (30-µm SiO(2)) before sintering; Gr3-air abrasion with 50-µm Al(2)O(3) before sintering; Gr4-air abrasion with 110-µ Al(2)O(3) before sintering; Gr5 - air abrasion with 50-µm Al(2)O(3) after sintering. After specimen preparation, cylinders of composite resin were prepared and immediately cemented onto the ceramic. A shear test was performed. RESULTS: One-way ANOVA indicated a statistically significant difference among the groups (p= 0.0019). The mean shear bond strengths (MPa) were: Gr1 = 4.7 ± 0.8,(b) Gr2 = 4.6 ± 0.9,(b) Gr3 = 6.4 ± 1.0,(a) Gr4 = 6.5 ± 1.8,(a) Gr5 = 6 ± 1.3(ab) (same superscript letter indicates statistical similarity). Adhesive fracture between the ceramic and resin cement was the most common failure. No complete cohesive fracture at the ceramic or composite cylinders was noted. CONCLUSION: Within the limitations of this study, additional surface treatment with air abrasion before and after sintering provided a significant increase in bond strength. Tribochemical silica coating before sintering was not effective as a surface treatment.


Assuntos
Colagem Dentária , Porcelana Dentária , Cimentos de Resina , Abrasão Dental por Ar , Análise do Estresse Dentário , Temperatura Alta , Projetos Piloto , Resistência ao Cisalhamento , Dióxido de Silício , Propriedades de Superfície , Ítrio , Zircônio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA