Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Anal Chem ; 94(50): 17379-17387, 2022 12 20.
Artigo em Inglês | MEDLINE | ID: mdl-36490367

RESUMO

The pandemic readiness toolbox needs to be extended, targeting different biomolecules, using orthogonal experimental set-ups. Here, we build on our Cov-MS effort using LC-MS, adding SISCAPA technology to enrich proteotypic peptides of the SARS-CoV-2 nucleocapsid (N) protein from trypsin-digested patient samples. The Cov2MS assay is compatible with most matrices including nasopharyngeal swabs, saliva, and plasma and has increased sensitivity into the attomole range, a 1000-fold improvement compared to direct detection in a matrix. A strong positive correlation was observed with qPCR detection beyond a quantification cycle of 30-31, the level where no live virus can be cultured. The automatable sample preparation and reduced LC dependency allow analysis of up to 500 samples per day per instrument. Importantly, peptide enrichment allows detection of the N protein in pooled samples without sensitivity loss. Easily multiplexed, we detect variants and propose targets for Influenza A and B detection. Thus, the Cov2MS assay can be adapted to test for many different pathogens in pooled samples, providing longitudinal epidemiological monitoring of large numbers of pathogens within a population as an early warning system.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , Teste para COVID-19 , Técnicas de Laboratório Clínico/métodos , Espectrometria de Massas/métodos , Peptídeos , Sensibilidade e Especificidade
2.
JACS Au ; 1(6): 750-765, 2021 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-34254058

RESUMO

Rising population density and global mobility are among the reasons why pathogens such as SARS-CoV-2, the virus that causes COVID-19, spread so rapidly across the globe. The policy response to such pandemics will always have to include accurate monitoring of the spread, as this provides one of the few alternatives to total lockdown. However, COVID-19 diagnosis is currently performed almost exclusively by reverse transcription polymerase chain reaction (RT-PCR). Although this is efficient, automatable, and acceptably cheap, reliance on one type of technology comes with serious caveats, as illustrated by recurring reagent and test shortages. We therefore developed an alternative diagnostic test that detects proteolytically digested SARS-CoV-2 proteins using mass spectrometry (MS). We established the Cov-MS consortium, consisting of 15 academic laboratories and several industrial partners to increase applicability, accessibility, sensitivity, and robustness of this kind of SARS-CoV-2 detection. This, in turn, gave rise to the Cov-MS Digital Incubator that allows other laboratories to join the effort, navigate, and share their optimizations and translate the assay into their clinic. As this test relies on viral proteins instead of RNA, it provides an orthogonal and complementary approach to RT-PCR using other reagents that are relatively inexpensive and widely available, as well as orthogonally skilled personnel and different instruments. Data are available via ProteomeXchange with identifier PXD022550.

3.
J Am Soc Mass Spectrom ; 30(11): 2228-2237, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31452089

RESUMO

Modern mass spectrometry methods provide a huge benefit to saponin structural characterization, especially when combined with collision-induced dissociation experiments to obtain a partial description of the saponin (ion) structure. However, the complete description of the structures of these ubiquitous secondary metabolites remain challenging, especially since isomeric saponins presenting small differences are often present in a single extract. As a typical example, the horse chestnut triterpene glycosides, the so-called escins, comprise isomeric saponins containing subtle differences such as cis-trans ethylenic configuration (stereoisomers) of a side chain or distinct positions of an acetyl group (regioisomers) on the aglycone. In the present paper, the coupling of liquid chromatography and ion mobility mass spectrometry has been used to distinguish regioisomeric and stereoisomeric saponins. Ion mobility arrival time distributions (ATDs) were recorded for the stereoisomeric and regioisomeric saponin ions demonstrating that isomeric saponins can be partially separated using ion mobility on a commercially available traveling wave ion mobility (TWIMS) mass spectrometer. Small differences in the ATD can only be monitored when the isomeric saponins are separated with liquid chromatography prior to the IM-MS analysis. However, gas phase separation between stereoisomeric and regioisomeric saponin ions can be successfully realized, without any LC separation, on a cyclic ion mobility-enabled quadrupole time-of-flight (Q-cIM-oaToF) mass spectrometer. The main outcome of the present paper is that the structural analysis of regioisomeric and stereoisomeric natural compounds that represents a real challenge can take huge advantages of ion mobility experiments but only if increased ion mobility resolution is attainable.

4.
J Am Soc Mass Spectrom ; 28(11): 2492-2499, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28808984

RESUMO

Ion mobility-mass spectrometry (IM-MS) has emerged as a powerful separation and identification tool to characterize synthetic polymer mixtures and topologies (linear, cyclic, star-shaped,…). Electrospray coupled to IM-MS already revealed the coexistence of several charge state-dependent conformations for a single charge state of biomolecules with strong intramolecular interactions, even when limited resolving power IM-MS instruments were used. For synthetic polymers, the sample's polydispersity allows the observation of several chain lengths. A unique collision cross-section (CCS) trend is usually observed when increasing the degree of polymerization (DP) at constant charge state, allowing the deciphering of different polymer topologies. In this paper, we report multiple coexisting CCS trends when increasing the DP at constant charge state for linear poly(acrylamide) PAAm in the gas phase. This is similar to observations on peptides and proteins. Biomolecules show in addition population changes when collisionally heating the ions. In the case of synthetic PAAm, fragmentation occurred before reaching the energy for conformation conversion. These observations, which were made on two different IM-MS instruments (SYNAPT G2 HDMS and high resolution multi-pass cyclic T-Wave prototype from Waters), limit the use of ion mobility for synthetic polymer topology interpretations to polymers where unique CCS values are observed for each DP at constant charge state. Graphical Abstract ᅟ.

5.
Talanta ; 169: 30-36, 2017 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-28411818

RESUMO

Boar taint is a contemporary off-odor present in meat of uncastrated male pigs. As European Member States intend to abandon surgical castration of pigs by 2018, this off-odor has gained a lot of research interest. In this study, rapid evaporative ionization mass spectrometry (REIMS) was explored for the rapid detection of boar taint in neck fat. Untargeted screening of samples (n=150) enabled discrimination between sow, tainted and untainted boars. The obtained OPLS-DA models showed excellent classification accuracy, i.e. 99% and 100% for sow and boar samples or solely boar samples, respectively. Furthermore, the obtained models demonstrated excellent validation characteristics (R2(Y)=0.872-0.969; Q2(Y)=0.756-0.917), which were confirmed by CV-ANOVA (p<0.001) and permutation testing. In conclusion, in this work for the first time highly accurate and high-throughput (<10s) classification of tainted and untainted boar samples was achieved, rendering REIMS a promising technique for predictive modelling in food safety and quality applications.


Assuntos
Tecido Adiposo/química , Androsterona/análise , Análise de Alimentos/instrumentação , Ensaios de Triagem em Larga Escala/instrumentação , Espectrometria de Massas/instrumentação , Carne/análise , Tecido Adiposo/metabolismo , Animais , Análise de Alimentos/métodos , Ensaios de Triagem em Larga Escala/métodos , Humanos , Masculino , Espectrometria de Massas/métodos , Suínos
6.
Drug Test Anal ; 7(9): 835-42, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26017115

RESUMO

Cerebrolysin, a parenteral peptide preparation produced by controlled digestion of porcine brain proteins, is an approved nootropic medicine in some countries. However, it is also easily and globally available on the Internet. Nevertheless, until now, its exact chemical composition was unknown. Using high performance liquid chromatography (HPLC) coupled to ion trap and ultra high performance liquid chromatography (UHPLC) coupled to quadrupole-ion mobility-time-of-flight mass spectrometry (Q-IM-TOF MS), combined with UniProt pig protein database search and PEAKS de novo sequencing, we identified 638 unique peptides in an Internet-obtained Cerebrolysin sample. The main components in this sample originate from tubulin alpha- and beta-chain, actin, and myelin basic protein. No fragments of known neurotrophic factors like glial cell-derived neurotrophic factor (GDNF), neurotrophin nerve growth factor (NGF), brain-derived neurotrophic factor (BDNF), and ciliary neurotrophic factor (CNTF) were found, suggesting that the activities reported in the literature are likely the result of new, hitherto unknown cryptic peptides with nootropic properties.


Assuntos
Aminoácidos/química , Fármacos Neuroprotetores/química , Peptídeos/análise , Proteínas/análise , Sequência de Aminoácidos , Aminoácidos/provisão & distribuição , Animais , Cromatografia Líquida de Alta Pressão , Internet , Dados de Sequência Molecular , Fármacos Neuroprotetores/provisão & distribuição , Espectrometria de Massas por Ionização por Electrospray , Suínos
7.
Bioanalysis ; 7(5): 605-19, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25826142

RESUMO

AIM: An ultrasensitive nano UHPLC-ESI-MS/MS method is developed to simultaneously monitor three low-concentration neuromedin-like peptides in microdialysates. RESULTS: Peptide preconcentration and sample desalting is performed online on a trap column. A shallow gradient slope at 300 nl/min on the analytical column maintained at 35°C, followed by two saw-tooth column wash cycles, results in the highest sensitivity and the lowest carryover. The validated method allows the accurate and precise quantification of 0.5 pM neurotensin and neuromedin N (2.5 amol on column), and of 3.0 pM neuromedin B (15.0 amol on column) in in vivo microdialysates without the use of internal standards. CONCLUSION: The assay is an important tool for elucidating the role of these neuromedin-like peptides in the pathophysiology of neurological disorders.


Assuntos
Cromatografia Líquida/métodos , Microdiálise/métodos , Neurotensina/metabolismo , Fragmentos de Peptídeos/metabolismo , Peptídeos/metabolismo , Espectrometria de Massas em Tandem/métodos
8.
J Chromatogr A ; 1360: 217-28, 2014 Sep 19.
Artigo em Inglês | MEDLINE | ID: mdl-25145562

RESUMO

Obtaining maximal sensitivity of nano UHPLC-MS/MS methods is primordial to quantify picomolar concentrations of neuropeptides in microdialysis samples. Since aspecific adsorption of peptides to Eppendorf tubes, pipette tips and UHPLC vials is detrimental for method sensitivity, a strategy is presented to reduce adsorption of these peptides during standard preparation. Within this respect, all procedural steps from dissolution of the lyophilized powder until the injection of the sample onto the system are investigated. Two peptides of the neuromedin family, i.e. neuromedin B and neuromedin N, and a neuromedin N-related neuropeptide, neurotensin, are evaluated. The first part of this study outlines a number of parameters which are known to affect peptide solubility. The main focus of the second part involves the optimization of the sample composition in the UHPLC vial by using design of experiments. Contradictory findings are observed concerning the influence of acetonitrile, salts and matrix components. They are found important for injection of the peptides into the system, but crucially need to be excluded from the dilution solvent. Furthermore, the type of surface material, temperature and the pipetting protocol considerably affect the adsorption phenomenon. Statistical analysis on the results of the central composite design reveals that the highest peptide responses are obtained with the injection solvent consisting of 13.1% V/V ACN and 4.4% V/V FA. This aspect of the optimization strategy can be identified as the main contributor to the gain in method sensitivity. Since the reduction of peptide adsorption and the optimization of the injection solvent resulted in a clear and quantifiable signal of the three peptides, optimization of both issues should be considered in the early stage of method development, in particular when the analysis of low-concentration peptide solutions is envisaged.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Neurotensina/análise , Fragmentos de Peptídeos/análise , Espectrometria de Massas em Tandem/métodos , Adsorção , Fenômenos Químicos , Solventes/química , Propriedades de Superfície
9.
Rapid Commun Mass Spectrom ; 25(23): 3497-503, 2011 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-22095497

RESUMO

Travelling wave ion mobility spectrometry - mass spectrometry (TWIMS-MS) was evaluated as a tool for structural identification of metabolites of small molecule drugs in cases where the exact position of the biotransformation could not be identified by conventional tandem mass spectrometry. Test sets of compounds containing biotransformations at aromatic positions were analyzed. These present a problem for traditional MS methods since an atomic level localization of the biotransformation cannot normally be determined from MS(n) spectra. In addition to ion mobility measurements of the intact metabolite ions, ion mobility measurements of product ions were also made and the results compared with calculated values. This approach reduces the complexity of the problem, making theoretical calculations easier and more predictable when a modeled collision cross section (CCS) is required. A good relative correspondence between theoretical and measured CCSs was obtained allowing the identification of the exact position of the biotransformation. It was also demonstrated that authentic standards with substructures identical to those in the unknown can be used to assign the exact position of the biotransformation. In this approach the identification was based on the comparison of the drift times or CCSs for product ions of the standard, with those of the same product ions in the unknown.


Assuntos
Preparações Farmacêuticas/química , Preparações Farmacêuticas/metabolismo , Espectrometria de Massas em Tandem/métodos , Biotransformação , Simulação por Computador , Íons/química , Íons/metabolismo , Isomerismo , Relação Estrutura-Atividade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA