Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
Phys Rev Lett ; 129(16): 165001, 2022 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-36306746

RESUMO

Tokamak operational regimes with small edge localized modes (ELMs) could be a solution to the problem of large transient heat loads in fusion reactors. A ballooning mode near the last closed flux surface governed by the pressure gradient and the magnetic shear there has been proposed for small ELMs. In this Letter, we experimentally investigate several stabilizing effects near the last closed flux surface and present linear ideal simulations that indeed develop ballooninglike fluctuations there and connect them with nonlinear resistive simulations. The dimensionless parameters of the small ELM regime in the region of interest are very similar to those in a reactor, making this regime the ideal exhaust scenario for a future device.

2.
Phys Rev Lett ; 128(18): 185003, 2022 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-35594105

RESUMO

A first-principles scaling law, based on turbulent transport considerations, and a multimachine database of density limit discharges from the ASDEX Upgrade, JET, and TCV tokamaks, show that the increase of the boundary turbulent transport with the plasma collisionality sets the maximum density achievable in tokamaks. This scaling law shows a strong dependence on the heating power, therefore predicting for ITER a significantly larger safety margin than the Greenwald empirical scaling [Greenwald et al., Nucl. Fusion, 28, 2199 (1988)NUFUAU0029-551510.1088/0029-5515/28/12/009] in case of unintentional high-to-low confinement transition.

3.
Rev Sci Instrum ; 93(2): 023507, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-35232131

RESUMO

A new high heat flux ball-pen probe head installed on the midplane manipulator is currently being used in ASDEX-Upgrade (AUG). The probe was designed to withstand high heat fluxes making possible the investigation of the plasma edge under harsh conditions, such as low power H-mode. Composed of seven pins (four Langmuir probes, mounted in two Mach probe pairs, and three ball-pen probes), the new probe head allows us to measure several plasma parameters simultaneously and with high temporal resolution. A novel method to correct the sheath potential dynamically accounting for the total secondary electron emission is introduced together with applications to obtain the electron temperature and plasma potential profiles. The total secondary electron emission yield is obtained from particle in cell simulations in AUG condition and probe realistic impact angle with respect to the magnetic field. Finally, the probe capability to investigate turbulence around the separatrix of AUG is discussed.


Assuntos
Elétrons , Temperatura Alta , Temperatura
4.
Transfus Apher Sci ; 60(5): 103172, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34059472

RESUMO

The aim of the study was to investigate safety and if extracorporeal photopheresis (ECP) may change health criteria (HC) and quality of life (QoL). MATERIAL AND METHOD: 560 patients (33 % women) were treated with ECP for a total of 13,871 procedures during a 17-years period. Mean age was 48 years (±18, range 3-81 years). Self-estimation of QoL was graded: 0 (suicidal) up to 10 (best ever) and HC: 0 (Bed ridden, ICU condition) up to 10 (athletic). Adverse events were analyzed. ANOVA and paired comparisons were performed. RESULTS: Patients were treated due to graft versus host disease (GVHD, n = 317), skin lymphoma (n = 70), solid organ transplants (n = 47), skin diseases (n = 20) and other diseases (n = 106). Adverse events (AEs) were registered in 5.4 % of the first treatments and in 1.2 % of the subsequent procedures. Severe AEs were present in 0.04 % of all procedures. No patient died due to the procedure. Tingling and stitching were the most common AE. For those with GVHD an improvement was noticed within approximately 10 procedures of ECP in the severity stage, QoL (from a mean of 6.1 to 6.8, p < 0.002) and the HC (6.1 -> 6.4, p < 0.014) and improved further with added procedures. CONCLUSION: Photopheresis is an established therapy with few side effects. The present study of soft variables indicate that GVHD shows benefits upon ECP within approximately 10 procedures in regard to the severity of mainly skin GVHD, and lower baseline levels of HC and QoL.


Assuntos
Doença Enxerto-Hospedeiro/terapia , Linfoma/terapia , Fotoferese/métodos , Neoplasias Cutâneas/terapia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Doença Crônica , Feminino , Doença Enxerto-Hospedeiro/psicologia , Hemodinâmica , Humanos , Linfoma/psicologia , Masculino , Pessoa de Meia-Idade , Qualidade de Vida , Sistema de Registros , Estudos Retrospectivos , Neoplasias Cutâneas/psicologia , Adulto Jovem
5.
Transfus Apher Sci ; 58(5): 641-644, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31519525

RESUMO

OBJECTIVE: The World Apheresis Association (WAA) register contains data from more than 89 000 apheresis procedures in more than 12,000 patients. The aim of this study was to evaluate functional health and quality of life (QoL) in patients during apheresis treatment. MATERIAL AND METHODS: Estimates of health condition (HC) were made in 40,445 and of QoL in 22112 apheresis procedures. This study focused on a 10-step graded evaluation of HC (scale from: 'bedridden, unable to eat' to a level of 'athletic competition') and self-assessment of QoL (scale from: worst ever '0' to best ever '10'). Data were compared in relation to various apheresis procedures and if the patient underwent the first or subsequent apheresis procedure. RESULTS: Of the patients treated with plasma exchange (PEX) with centrifugation technique (n = 15787) 10% were 'bedridden, unable to come out of bed' while for patients treated with plasma filtration technique (n = 1018) the percentage was 27%. During the first procedure these figures were 16% and 30%, respectively. Self-estimates of QoL were graded 'zero' or '1' in 1.6% of patients during the first apheresis procedure; At the first contact patients undergoing PEX graded like this in 4.3%. CONCLUSION: Many of the patients undergoing apheresis treatment have poor HC and QoL at the start of therapy. Of all therapeutic apheresis procedures patients undergoing PEX had the lowest score of QoL.


Assuntos
Troca Plasmática , Qualidade de Vida , Sistema de Registros , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
6.
Rev Sci Instrum ; 88(3): 033509, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28372367

RESUMO

In magnetically confined fusion plasmas controlled gas injection is crucial for plasma fuelling as well as for various diagnostic applications such as active spectroscopy. We present a new, versatile system for the injection of collimated thermal gas beams into a vacuum chamber. This system consists of a gas pressure chamber, sealed by a custom made piezo valve towards a small capillary for gas injection. The setup can directly be placed inside of the vacuum chamber of fusion devices as it is small and immune against high magnetic fields. This enables gas injection close to the plasma periphery with high duty cycles and fast switch on/off times ≲ 0.5 ms. In this work, we present the design details of this new injection system and a systematic characterization of the beam properties as well as the gas flowrates which can be accomplished. The thin and relatively short capillary yields a small divergence of the injected beam with a half opening angle of 20°. The gas box is designed for pre-fill pressures of 10 mbar up to 100 bars and makes a flowrate accessible from 1018 part/s up to 1023 part/s. It hence is a versatile system for both diagnostic as well as fuelling applications. The implementation of this system in ASDEX Upgrade will be described and its application for line ratio spectroscopy on helium will be demonstrated on a selected example.

7.
Rev Sci Instrum ; 86(11): 113502, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26628130

RESUMO

Infrared (IR) thermography is widely used in fusion research to study power exhaust and incident heat load onto the plasma facing components. Due to the short pulse duration of today's fusion experiments, IR systems have mostly been designed for off-line data analysis. For future long pulse devices (e.g., Wendelstein 7-X, ITER), a real time evaluation of the target temperature and heat flux is mandatory. This paper shows the development of a real time capable IR system for ASDEX Upgrade. A compact IR camera has been designed incorporating the necessary magnetic and electric shielding for the detector, cooler assembly. The camera communication is based on the Camera Link industry standard. The data acquisition hardware is based on National Instruments hardware, consisting of a PXIe chassis inside and a fibre optical connected industry computer outside the torus hall. Image processing and data evaluation are performed using real time LabVIEW.

8.
Rev Sci Instrum ; 85(3): 033503, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24689581

RESUMO

In the ASDEX Upgrade tokamak, a radiation measurement for a wide spectral range, based on semiconductor detectors, with 256 lines of sight and a time resolution of 5 µs was recently installed. In combination with the foil based bolometry, it is now possible to estimate the absolutely calibrated radiated power of the plasma on fast timescales. This work introduces this diagnostic based on AXUV (Absolute eXtended UltraViolet) n-on-p diodes made by International Radiation Detectors, Inc. The measurement and the degradation of the diodes in a tokamak environment is shown. Even though the AXUV diodes are developed to have a constant sensitivity for all photon energies (1 eV-8 keV), degradation leads to a photon energy dependence of the sensitivity. The foil bolometry, which is restricted to a time resolution of less than 1 kHz, offers a basis for a time dependent calibration of the diodes. The measurements of the quasi-calibrated diodes are compared with the foil bolometry and found to be accurate on the kHz time scale. Therefore, it is assumed, that the corrected values are also valid for the highest time resolution (200 kHz). With this improved diagnostic setup, the radiation induced by edge localized modes is analyzed on fast timescales.

9.
Rev Sci Instrum ; 85(12): 123507, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25554293

RESUMO

In a Tokamak the configuration of the magnetic fields remains the key element to improve performance and to maximise the scientific exploitation of the device. On the other hand, the quality of the reconstructed fields depends crucially on the measurements available. Traditionally in the least square minimisation phase of the algorithms, used to obtain the magnetic field topology, all the diagnostics are given the same weights, a part from a corrective factor taking into account the error bars. This assumption unduly penalises complex diagnostics, such as polarimetry, which have a limited number of highly significant measurements. A completely new method to choose the weights, to be given to the internal measurements of the magnetic fields for improved equilibrium reconstructions, is presented in this paper. The approach is based on various statistical indicators applied to the residuals, the difference between the actual measurements and their estimates from the reconstructed equilibrium. The potential of the method is exemplified using the measurements of the Faraday rotation derived from JET polarimeter. The results indicate quite clearly that the weights have to be determined carefully, since the inappropriate choice can have significant repercussions on the quality of the magnetic reconstruction both in the edge and in the core. These results confirm the limitations of the assumption that all the diagnostics have to be given the same weight, irrespective of the number of measurements they provide and the region of the plasma they probe.

10.
Rev Sci Instrum ; 83(10): 10D530, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23130793

RESUMO

For the new ITER-like wall at JET, two new infrared diagnostics (KL9B, KL3B) have been installed. These diagnostics can operate between 3.5 and 5 µm and up to sampling frequencies of ∼20 kHz. KL9B and KL3B image the horizontal and vertical tiles of the divertor. The divertor tiles are tungsten coated carbon fiber composite except the central tile which is bulk tungsten and consists of lamella segments. The thermal emission between lamellae affects the surface temperature measurement and therefore KL9A has been upgraded to achieve a higher spatial resolution (by a factor of 2). A technical description of KL9A, KL9B, and KL3B and cross correlation with a near infrared camera and a two-color pyrometer is presented.

11.
Phys Rev Lett ; 107(21): 215001, 2011 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-22181888

RESUMO

Experimental measurements of the SOL power decay length (λ(q)) estimated from analysis of fully attached divertor heat load profiles from two tokamaks, JET and ASDEX Upgrade, are presented. Data was measured by means of infrared thermography. An empirical scaling reveals parametric dependency λ(q) in mm = 0.73B(T)(-0.78)q(cyl)(1.2)P(SOL)(0.1)R(geo)(0), where B(T)(T) describes the toroidal magnetic field, q(cyl) the cylindrical safety factor, P(SOL)(MW) the power crossing the separatrix and R(geo)(m) the major radius of the device. A comparison of these measurements to a heuristic particle drift-based model shows satisfactory agreement in both absolute magnitude and scaling. Extrapolation to ITER gives λ(q) ≃ 1 mm.

12.
Phys Rev Lett ; 106(22): 225004, 2011 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-21702608

RESUMO

First experiments with nonaxisymmetric magnetic perturbations, toroidal mode number n=2, produced by newly installed in-vessel saddle coils in the ASDEX Upgrade tokamak show significant reduction of plasma energy loss and peak divertor power load associated with type-I edge localized modes (ELMs) in high-confinement mode plasmas. ELM mitigation is observed above an edge density threshold and is obtained both with magnetic perturbations that are resonant and not resonant with the edge safety factor profile. Compared with unperturbed type-I ELMy reference plasmas, plasmas with mitigated ELMs show similar confinement, similar plasma density, and lower tungsten impurity concentration.

13.
J Nucl Mater ; 415(1): S860-S864, 2011 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-30976128

RESUMO

We present results of massively parallel kinetic simulations of the triple Langmuir probes at JET. These results indicate that the probes under certain conditions, e.g. during ELMs, can significantly under/over estimate the electron temperature.

14.
Rev Sci Instrum ; 81(10): 10E132, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21061487

RESUMO

Any plasma diagnostic in ITER must be able to operate at temperatures in excess of 200 °C and neutron loads corresponding to 0.1 dpa over its lifetime. To achieve this aim for the bolometer diagnostic, a miniaturized metal resistor bolometer detector based on Pt absorbers galvanically deposited on SiN membranes is being developed. The first two generations of detectors featured up to 4.5 µm thick absorbers. Results from laboratory tests are presented characterizing the dependence of their calibration constants under thermal loads up to 450 °C. Several detectors have been tested in ASDEX Upgrade providing reliable data but also pointing out the need for further optimization. A laser trimming procedure has been implemented to reduce the mismatch in meander resistances below 1% for one detector and the thermal drifts from this mismatch.

15.
Phys Rev Lett ; 104(18): 185003, 2010 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-20482186

RESUMO

We report the identification of a localized current structure inside the JET plasma. It is a field-aligned closed helical ribbon, carrying current in the same direction as the background current profile (cocurrent), rotating toroidally with the ion velocity (corotating). It appears to be located at a flat spot in the plasma pressure profile, at the top of the pedestal. The structure appears spontaneously in low density, high rotation plasmas, and can last up to 1.4 s, a time comparable to a local resistive time. It considerably delays the appearance of the first edge localized mode.

16.
Am J Transplant ; 9(12): 2816-24, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19845588

RESUMO

The fate of islets in clinical transplantation is unclear. To elude on this positron emission tomography combined with computed tomography (PET/CT) was performed for 60 min during islet transplantation in five patients receiving six transplants. A fraction of the islets (23%) were labeled with 18F-fluorodeoxyglucose ([(18)F]FDG) and carefully mixed with unlabeled islets just prior to intraportal transplantation. The peak radioactivity concentration in the liver was found at 19 min after start of islet infusion and corresponded to only 75% of what was expected, indicating that islets are lost during the transplantation procedure. No accumulation of radioactivity was found in the lungs. A nonphysiological peak of C-peptide was found in plasma during and immediately after transplantation in all subjects. Distribution in the liver was heterogeneous with wide variations in location and concentration. Islets found in areas with concentrations of >400 IEQ/cc liver tissue varied between 1% and 32% of the graft in different subjects. No side effects attributed to the PET/CT procedure were found. Clinical outcome in all patients was comparable to that previously observed indicating that the [(18)F]FDG labeling procedure did not harm the islets. The technique has potential to be used to assess approaches to enhance islet survival and engraftment in clinical transplantation.


Assuntos
Transplante das Ilhotas Pancreáticas/métodos , Tomografia por Emissão de Pósitrons/métodos , Adulto , Idoso , Peptídeo C/sangue , Feminino , Fluordesoxiglucose F18 , Humanos , Inflamação/sangue , Fígado/diagnóstico por imagem , Fígado/metabolismo , Masculino , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos , Tomografia Computadorizada por Raios X
17.
Transplant Proc ; 37(2): 1313-4, 2005 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15848707

RESUMO

INTRODUCTION: A key factor for successful islet isolation is to place the optimal amount of enzyme into the pancreatic ducts prior to starting digestion of pancreatic glands. To improve this procedure, we introduced novel techniques to identify and repair tissue damage resulting in leakage of collagenase solution. MATERIALS AND METHODS: One hundred twelve standardized consecutive islet isolations were for the effects of dye and glue on islet yield, islet function using a perifusion assay, and the possibility of clinical transplantation. One group of pancreata (n = 26) obtained en bloc together with duodenum were carefully detached with ligation of accessory ducts in an isolation unit (WPD group), whereas the pancreata were dissected from the duodenum in the operating room in the other 86 isolations. In 28 of 86 isolations, whole glands were used (WP group), while only the body and tail area were applied in the remaining 58 isolations (PP group). RESULTS: Both dye and glue effectively prevented leakage of collagenase from the gland. Both islet yield and success rate were higher with these tools without adverse effects on islet function or collagenase activity. The success rate of isolations and islet yield were significantly higher in the WPD group (P = .02 and .001, respectively). CONCLUSIONS: Dye and glue may be useful tools to improve human islet isolation procedures. In addition, the use of the whole pancreas further improves the outcome.


Assuntos
Ilhotas Pancreáticas/citologia , Pâncreas/citologia , Adesivos , Separação Celular/métodos , Corantes , Humanos , Ilhotas Pancreáticas/fisiologia , Pâncreas/fisiologia , Pancreatectomia
18.
Transplant Proc ; 37(2): 1315-6, 2005 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15848708

RESUMO

BACKGROUND: To further improve the outcome of clinical islet transplantation analysis of the impact of donor- and process-related factors could be of great importance. MATERIALS AND METHODS: Thirty-eight consecutive clinical islet transplantations were performed with consecutive islet isolations. Univariate analysis for donor- and isolation-related variables were correlated with recipient C-peptide levels at 2 and 4 weeks after transplantation. "Warm ischemia time" was defined as the time from start of University of Wisconsin solution perfusion in the donor until the pancreas was removed to the back table. RESULTS: Short "warm ischemia time" (WIT), low expression of tissue factor (TF) in pancreatic tissue, and high creatinine levels in the donor were variables related to high C-peptide values after islet transplantation. Furthermore, hospitalization length longer than 4 days was associated with low C-peptide levels. The number of islet equivalents (IEQ) did not correlate with the clinical outcome, possibly due to the fact that IEQ number was included in the release criteria for clinical islet transplantation CONCLUSIONS: Successful clinical islet transplantation is strongly correlated with donor and pancreas procurement factors rather than isolation process-related variables. "WIT" may induce TF expression in the pancreatic tissues. TF has been identified as the main trigger of the instant blood-mediated-inflammatory reaction in clinical islet transplantation. Therefore, assay of TF expression in pancreatic tissues could be applied as useful screening tool to identify "good" pancreata for clinical transplantation.


Assuntos
Transplante das Ilhotas Pancreáticas/métodos , Ilhotas Pancreáticas/citologia , Análise de Variância , Peptídeo C/análise , Separação Celular/métodos , Humanos , Isquemia , Ilhotas Pancreáticas/irrigação sanguínea , Transplante das Ilhotas Pancreáticas/fisiologia
19.
Phys Rev Lett ; 91(19): 195003, 2003 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-14611587

RESUMO

In the ASDEX Upgrade tokamak, complex power deposition structures on the divertor target plates during type-I edge-localized modes (ELMs) have been discovered by fast (few microseconds), two-dimensional (40 x 40 cm(2)) infrared thermography. In addition to the usual axisymmetric power deposition line near the separatrix, there appear, statistically distributed, several laterally displaced and inclined stripes, mostly well separated from each other and from the main strike zone. These structures are interpreted as footprints of approximately field aligned, helical perturbations at the low field side of the main plasma edge related to the nonlinear ELM evolution. Based on this picture, the ELM related mode structure can be derived from the target load pattern, yielding on average toroidal mode numbers in a range of 8-24.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA