Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
2.
Thromb Res ; 133(6): 1074-8, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24485951

RESUMO

BACKGROUND: Accurate diagnosis of heparin-induced thrombocytopenia (HIT) is essential but remains challenging. We have previously demonstrated, in a retrospective study, the usefulness of the combination of the 4Ts score, AcuStar HIT and heparin-induced multiple electrode aggregometry (HIMEA) with optimized thresholds. OBJECTIVES: We aimed at exploring prospectively the performances of our optimized diagnostic algorithm on suspected HIT patients. The secondary objective is to evaluate performances of AcuStar HIT-Ab (PF4-H) in comparison with the clinical outcome. METHODS: 116 inpatients with clinically suspected immune HIT were included. Our optimized diagnostic algorithm was applied to each patient. Sensitivity, specificity, negative predictive value (NPV), positive predictive value (PPV) of the overall diagnostic strategy as well as AcuStar HIT-Ab (at manufacturer's thresholds and at our thresholds) were calculated using clinical diagnosis as the reference. RESULTS: Among 116 patients, 2 patients had clinically-diagnosed HIT. These 2 patients were positive on AcuStar HIT-Ab, AcuStar HIT-IgG and HIMEA. Using our optimized algorithm, all patients were correctly diagnosed. AcuStar HIT-Ab at our cut-off (>9.41 U/mL) and at manufacturer's cut-off (>1.00 U/mL) showed both a sensitivity of 100.0% and a specificity of 99.1% and 90.4%, respectively. CONCLUSION: The combination of the 4Ts score, the HemosIL® AcuStar HIT and HIMEA with optimized thresholds may be useful for the rapid and accurate exclusion of the diagnosis of immune HIT.


Assuntos
Anticoagulantes/efeitos adversos , Heparina/efeitos adversos , Trombocitopenia/induzido quimicamente , Trombocitopenia/diagnóstico , Diagnóstico Diferencial , Ensaio de Imunoadsorção Enzimática , Feminino , Humanos , Masculino , Agregação Plaquetária/efeitos dos fármacos , Testes de Função Plaquetária , Trombocitopenia/sangue , Trombocitopenia/imunologia
3.
Thromb Res ; 132(3): 352-9, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23803389

RESUMO

BACKGROUND: Early diagnosis of immune heparin-induced thrombocytopenia (HIT) is challenging. HemosIL® AcuStar HIT and heparin-induced multiple electrode aggregometry (HIMEA) were recently proposed as rapid diagnostic methods. OBJECTIVES: We conducted a study to assess performances of AcuStar HIT-IgG (PF4-H) and AcuStar HIT-Ab (PF4-H). The secondary objective was to compare the performances of the combination of Acustar HIT and HIMEA with standardised clinical diagnosis. METHODS: Sera of 104 suspected HIT patients were retrospectively tested with AcuStar HIT. HIMEA was performed on available sera (n=81). The clinical diagnosis was established by analysing in a standardized manner the patient's medical records. These tests were also compared with PF4-Enhanced®, LTA, and SRA in subsets of patients. Thresholds were determined using ROC curve analysis with clinical outcome as reference. RESULTS: Using the recommended thresholds (1.00AU), the negative predictive value (NPV) of HIT-IgG and HIT-Ab were 100.0% (95% CI: 95.9%-100.0% and 95.7%-100.0%). The positive predictive value (PPV) were 64.3% (95% CI: 35.1%-87.2.2%) and 45.0% (95% CI: 23.2%-68.6%), respectively. Using our thresholds (HIT-IgG: 2.89AU, HIT-Ab: 9.41AU), NPV of HIT-IgG and HIT-Ab were 100.0% (95% CI: 96.0%-100.0% and 96.1%-100.0%). PPV were 75.0% (95% CI: 42.7%-94.5%) and 81.8% (95% CI: 48.3%-97.7%), respectively. Of the 79 patients with a medium-high pretest probability score, 67 were negative using HIT-IgG (PF4-H) test at our thresholds. HIMEA was performed on HIT-IgG positive patients. Using this combination, only one patient on 79 was incorrectly diagnosed. CONCLUSION: Acustar HIT showed good performances to exclude the diagnosis of HIT. Combination with HIMEA improves PPV.


Assuntos
Heparina/efeitos adversos , Medições Luminescentes/métodos , Agregação Plaquetária/efeitos dos fármacos , Testes de Função Plaquetária/métodos , Trombocitopenia/induzido quimicamente , Trombocitopenia/diagnóstico , Adulto , Idoso , Automação , Estudos de Casos e Controles , Eletrodos , Ensaio de Imunoadsorção Enzimática , Feminino , Heparina/imunologia , Humanos , Medições Luminescentes/instrumentação , Masculino , Pessoa de Meia-Idade , Agregação Plaquetária/fisiologia , Estudos Retrospectivos , Trombocitopenia/sangue , Trombocitopenia/imunologia
4.
J Biomed Mater Res A ; 101(6): 1800-12, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23225706

RESUMO

Literature contains very few data about the potential biomedical application of amorphous hydrogenated carbon (a-C:H) thin films deposited by reactive pulsed magnetron discharge even so it is one of the most scalable plasma deposition technique. In this article, we show that such a C2H2 pulsed magnetron plasma produces high quality coating with good hemocompatibility and bioactive response: no effect on hemolysis and hemostasis were observed, and proliferation of various cell types such as endothelial, fibroblast, and osteoblast-like cells was not affected when the deposition conditions were varied. Cell growth on a-C:H coatings is proposed to take place by a two-step process: the initial cell contact is affected by the smooth topography of the a-C:H coatings, whereas the polymeric-like structure, together with a moderate hydrophilicity and a high hydrogen content, directs the posterior cell spreading while preserving the hemocompatible behavior.


Assuntos
Materiais Revestidos Biocompatíveis/farmacologia , Campos Magnéticos , Teste de Materiais , Citoesqueleto de Actina/efeitos dos fármacos , Citoesqueleto de Actina/metabolismo , Plaquetas/efeitos dos fármacos , Plaquetas/ultraestrutura , Linhagem Celular , Proliferação de Células/efeitos dos fármacos , Forma Celular/efeitos dos fármacos , Sobrevivência Celular/efeitos dos fármacos , Materiais Revestidos Biocompatíveis/química , Células Endoteliais/citologia , Células Endoteliais/efeitos dos fármacos , Células Endoteliais/metabolismo , Eritrócitos/citologia , Eritrócitos/efeitos dos fármacos , Fibroblastos/citologia , Fibroblastos/efeitos dos fármacos , Hemólise/efeitos dos fármacos , Humanos , Hidrocarbonetos Iodados/química , Hidrogenação/efeitos dos fármacos , Interleucina-8/metabolismo , Microscopia de Força Atômica , Osteoblastos/citologia , Osteoblastos/efeitos dos fármacos , Osteoblastos/metabolismo , Espectroscopia Fotoeletrônica , Tensão Superficial/efeitos dos fármacos , Água/química , Molhabilidade/efeitos dos fármacos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA