Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
1.
J Clin Med ; 12(16)2023 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-37629372

RESUMO

(1) Background: Fluid resuscitation is a necessary part of therapeutic measures to maintain sufficient hemodynamics in extracorporeal membrane oxygenation (ECMO) circulation. In a post-hoc analysis, we aimed to investigate the impact of increased volume therapy in veno-arterial ECMO circulation on renal function and organ edema in a large animal model. (2) Methods: ECMO therapy was performed in 12 female pigs (Deutsche Landrasse × Pietrain) for 10 h with subsequent euthanasia. Applicable volume, in regard to the necessary maintenance of hemodynamics, was divided into moderate and extensive volume therapy (MVT/EVT) due to the double quantity of calculated physiologic urine output for the planned study period. Respiratory and hemodynamic data were measured continuously. Additionally, renal function and organ edema were assessed by blood and tissue samples. (3) Results: Four pigs received MVT, and eight pigs received EVT. After 10 h of ECMO circulation, no major differences were seen between the groups in regard to hemodynamic and respiratory data. The relative change in creatinine after 10 h of ECMO support was significantly higher in EVT (1.3 ± 0.3 MVT vs. 1.8 ± 0.5 EVT; p = 0.033). No major differences were evident for lung, heart, liver, and kidney samples in regard to organ edema in comparison of EVT and MVT. Bowel tissue showed a higher percentage of edema in EVT compared to MVT (77 ± 2% MVT vs. 80 ± 3% EVT; p = 0.049). (4) Conclusions: The presented data suggest potential deterioration of renal function and intestinal mucosa function by an increase in tissue edema due to volume overload in ECMO therapy.

2.
Life (Basel) ; 12(11)2022 Nov 12.
Artigo em Inglês | MEDLINE | ID: mdl-36430994

RESUMO

(1) Introduction: Simultaneous ECMO and IABP therapy is frequently used. Haemodynamic changes responsible for the success of the concomitant mechanical circulatory support system approach are rarely investigated. In a large-animal model, we analysed haemodynamic parameters before and during ECMO therapy, comparing central and peripheral ECMO circulation with and without simultaneous IABP support. (2) Methods: Thirty-three female pigs were divided into five groups: (1) SHAM, (2) (peripheral)ECMO(-)IABP, (3) (p)ECMO(+)IABP, (4) (central)ECMO(-)IABP, and (5) (c)ECMO(+)IABP. Pigs were cannulated in accordance with the group and supported with ECMO (±IABP) for 10 h. Systemic haemodynamics, cardiac index (CI), and coronary and carotid artery blood flow were determined before, directly after, and at five and ten hours on extracorporeal support. Systemic inflammation (IL-6; IL-10; TNFα; IFNγ), immune response (NETs; cf-DNA), and endothelial injury (ET-1) were also measured. (3) Results: IABP support during antegrade ECMO circulation led to a significant reduction of left ventricular pressure in comparison to retrograde flow in (p)ECMO(-)IABP and (p)ECMO(+)IABP. Blood flow in the left anterior coronary and carotid artery was not affected by extracorporeal circulation. (4) Conclusions: Concomitant central ECMO and IABP therapy leads to significant reduction of intracavitary cardiac pressure, reduces cardiac work, and might therefore contribute to improved recovery in ECMO patients.

3.
Histochem Cell Biol ; 157(5): 513-524, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35229169

RESUMO

Animal models and clinical studies suggest an influence of angiotensin II (AngII) on the pathogenesis of liver diseases via the renin-angiotensin system. AngII application increases portal blood pressure, reduces bile flow, and increases permeability of liver tight junctions. Establishing the subcellular localization of angiotensin II receptor type 1 (AT1R), the main AngII receptor, helps to understand the effects of AngII on the liver. We localized AT1R in situ in human and porcine liver and porcine gallbladder by immunohistochemistry. In order to do so, we characterized commercial anti-AT1R antibodies regarding their capability to recognize heterologous human AT1R in immunocytochemistry and on western blots, and to detect AT1R using overlap studies and AT1R-specific blocking peptides. In hepatocytes and canals of Hering, AT1R displayed a tram-track-like distribution, while in cholangiocytes AT1R appeared in a honeycomb-like pattern; i.e., in liver epithelia, AT1R showed an equivalent distribution to that in the apical junctional network, which seals bile canaliculi and bile ducts along the blood-bile barrier. In intrahepatic blood vessels, AT1R was most prominent in the tunica media. We confirmed AT1R localization in situ to the plasma membrane domain, particularly between tight and adherens junctions in both human and porcine hepatocytes, cholangiocytes, and gallbladder epithelial cells using different anti-AT1R antibodies. Localization of AT1R at the junctional complex could explain previously reported AngII effects and predestines AT1R as a transmitter of tight junction permeability.


Assuntos
Bile , Receptor Tipo 1 de Angiotensina , Angiotensina II/metabolismo , Angiotensina II/farmacologia , Animais , Bile/metabolismo , Western Blotting , Humanos , Peptídeos , Receptor Tipo 1 de Angiotensina/metabolismo , Receptor Tipo 2 de Angiotensina , Suínos
4.
Int J Hyperthermia ; 38(1): 1174-1187, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34374624

RESUMO

PURPOSE: This article will report results from the in-vivo application of a previously published model-predictive control algorithm for MR-HIFU hyperthermia. The purpose of the investigation was to test the controller's in-vivo performance and behavior in the presence of heterogeneous perfusion. MATERIALS AND METHODS: Hyperthermia at 42°C was induced and maintained for up to 30 min in a circular section of a thermometry slice in the biceps femoris of German landrace pigs (n=5) using a commercial MR-HIFU system and a recently developed MPC algorithm. The heating power allocation was correlated with heat sink maps and contrast-enhanced MRI images. The temporal change in perfusion was estimated based on the power required to maintain hyperthermia. RESULTS: The controller performed well throughout the treatments with an absolute average tracking error of 0.27 ± 0.15 °C and an average difference of 1.25 ± 0.22 °C between T10 and T90. The MPC algorithm allocates additional heating power to sub-volumes with elevated heat sink effects, which are colocalized with blood vessels visible on contrast-enhanced MRI. The perfusion appeared to have increased by at least a factor of ∼1.86 on average. CONCLUSIONS: The MPC controller generates temperature distributions with a narrow spectrum of voxel temperatures inside the target ROI despite the presence of spatiotemporally heterogeneous perfusion due to the rapid thermometry feedback available with MR-HIFU and the flexible allocation of heating power. The visualization of spatiotemporally heterogeneous perfusion presents new research opportunities for the investigation of stimulated perfusion in hypoxic tumor regions.


Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade , Hipertermia Induzida , Algoritmos , Animais , Hipertermia , Imageamento por Ressonância Magnética , Perfusão , Suínos
5.
J Oral Maxillofac Surg ; 79(9): 1866-1873, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34051155

RESUMO

PURPOSE: Xenogeneic bone substitute materials are often used for augmentation of larger bone defects. Purification methods for these materials vary, mainly in terms of temperature. The aim of this study was to determine in vivo how sintering affects quantitative and qualitative bone regeneration of 2 bovine augmentation materials. METHODS: A total of 56 critical size defects were set at the frontal bone of 14 domestic pigs (4 each) and filled randomly with either bovine, sintered hydroxyapatite (BO), bovine, non-sintered hydroxyapatite (BOS), local autologous bone (AB) or left empty. All defects were additionally covered with a collagen membrane. Specimens were harvested after 4 and 8 weeks and were evaluated histologically and histomorphometrically. RESULTS: Histologically new bone could be seen in every group. Significantly highest new bone formation was found in AB. No significant difference could be detected between BO and BOS. CONCLUSIONS: According to the results of this study, sintered bone substitute material remains histologically distinguishable but does not affect quantitative and qualitative bone regeneration.


Assuntos
Matriz Óssea , Substitutos Ósseos , Animais , Regeneração Óssea , Bovinos , Projetos de Pesquisa , Suínos , Porco Miniatura
6.
Clin Oral Investig ; 25(6): 3729-3737, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33433653

RESUMO

OBJECTIVES: Biphasic calcium phosphate (BCP) is a bioceramic material successfully used in alloplastic bone augmentation. Despite many advantages, a disadvantage of BCP seems to be a difficult application and position instability. The aim of this study was to determine how different carrier materials influence BCP-induced quantitative and qualitative bone regeneration. MATERIALS AND METHODS: A total of 70 critical size defects were set in the frontal bone of 14 domestic pigs (5 each) and filled randomly with either BCP alone (BCP), BCP in combination with nano-hydroxyapatite (BCP + NHA), BCP embedded in native porcine type I/III collagen blocks (BCP + C), autologous bone (AB), or were left empty (ED). Specimens were harvested after 4 and 8 weeks and were evaluated histologically as well as histomorphometrically. RESULTS: Significantly lowest rate of new bone formation was found in ED (p = < 0.001) and BCP + NHA groups (p = 0.05). After 8 weeks, the highest percentage of new bone formation was observed in the BCP + C group. Fibrous matrix was detected highest in BCP alone. The lowest residual bone substitute material was found in BCP + C after 8 weeks. CONCLUSIONS: BCP-induced bone regeneration is indeed affected by different carrier types. Surface morphology and bioactive characteristics influence osseointegration and new bone formation in vivo. The combination of type I/III collagen seems most suitable for qualitative and quantitative bone regeneration. CLINICAL RELEVANCE: Stabilization of granular bone substitutes using type I/III collagen might be an alternative to granulates alone, indicating excellent volume stability, satisfactory plasticity, and easy application.


Assuntos
Substitutos Ósseos , Hidroxiapatitas , Animais , Regeneração Óssea , Substitutos Ósseos/farmacologia , Durapatita , Hidroxiapatitas/farmacologia , Osteogênese , Suínos
7.
Thorac Cardiovasc Surg ; 69(7): 649-659, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31030422

RESUMO

BACKGROUND: Scientific attempts to create the "ideal" small diameter vascular graft have been compared with the "search of the holy grail." Prosthetic material as expanded polytetrafluoroethylene or Dacron shows acceptable patency rates to large caliber vessels, while small diameter (< 6 mm) prosthetic conduits present unacceptably poor patency rates. Vascular tissue engineering represents a promising option to address this problem. MATERIAL AND METHODS: Thirty-two female Texel-sheep aged 6 months to 2 years underwent surgical common carotid artery (CCA) interposition using different tissue-engineered vascular substitutes. Explantation of the grafts was performed 12 (n = 12) and 36 (n = 20) weeks after surgery. Ultrasound was performed on postoperative day 1 and thereafter every 4 weeks to evaluate the graft patency. RESULTS: The average length of implanted substitutes was 10.3 ± 2.2 cm. Anesthesia and surgical procedure could be performed without major surgical complications in all cases.The grafts showed a systolic blood flow velocity (BFV) of 28.24 ± 13.5 cm/s, a diastolic BFV of 9.25 ± 4.53 cm/s, and a mean BFV of 17.85 ± 9.25 cm/s. Native vessels did not differ relevantly in hemodynamic measurements (systolic: 29.77 cm/s; diastolic: 7.99 cm/s ± 5.35; mean 15.87 ± 10.75). There was no incidence of neurologic complications or subsequent postoperative occlusion. Perioperative morbidity was low and implantation of conduits was generally well tolerated. CONCLUSION: This article aims to give a precise overview of in vivo experiments in sheep for the evaluation of small diameter vascular grafts performing CCA interposition, especially with regard to pitfalls and possible perioperative complications and to discuss advantages and disadvantages of this approach.


Assuntos
Implante de Prótese Vascular , Prótese Vascular , Animais , Implante de Prótese Vascular/efeitos adversos , Feminino , Oclusão de Enxerto Vascular , Politetrafluoretileno , Ovinos , Resultado do Tratamento , Grau de Desobstrução Vascular
8.
Int J Hyperthermia ; 37(1): 786-798, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32619373

RESUMO

Purpose: Pancreatic cancer is typically diagnosed in a late stage with limited therapeutic options. For those patients, ultrasound-guided high-intensity focused ultrasound (US-HIFU) can improve local control and alleviate pain. However, MRI-guided HIFU (MR-HIFU) has not yet been studied extensively in this context. To facilitate related research and accelerate clinical translation, we report a workflow for the in vivo HIFU ablation of the porcine pancreas under MRI guidance.Materials and methods: The pancreases of five healthy German landrace pigs (35-58 kg) were sonicated using a clinical MR-HIFU system. Acoustic access to the pancreas was supported by a specialized diet and a hydrogel compression device for bowel displacement. Organ motion was suspended using periods of apnea. The size of the resulting thermal lesions was assessed using the thermal threshold- and dose profiles, non-perfused volume, and gross examination. The effect of the compression device on beam path length was assessed using MRI imaging.Results: Eight of ten treatments resulted in clearly visible damage in the target tissue upon gross examination. Five treatments resulted in coagulative necrosis. Good agreement between the four metrics for lesion size and a clear correlation between the delivered energy dose and the resulting lesion size were found. The compression device notably shortened the intra-abdominal beam path.Conclusions: We demonstrated a workflow for HIFU treatment of the porcine pancreas in-vivo under MRI-guidance. This development bears significance for the development of MR-guided HIFU interventions on the pancreas as the pig is the preferred animal model for the translation of pre-clinical research into clinical application.


Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade , Imagem por Ressonância Magnética Intervencionista , Animais , Estudos de Viabilidade , Humanos , Imageamento por Ressonância Magnética , Pâncreas/diagnóstico por imagem , Pâncreas/cirurgia , Suínos
9.
Resusc Plus ; 1-2: 100006, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-34223293

RESUMO

AIM OF THE STUDY: Prognosis in out-of-hospital cardiac arrest (OHCA) depends on cardiopulmonary resuscitation (CPR) duration. Therefore, the optimal biphasic defibrillation waveform shows high conversion rates besides low energy. Matthew Fishler theoretically predicted it to be truncated ascending exponential. We realised a prototypic defibrillator and compared ascending with conventional rectangular waveforms in modelled OHCA and CPR. METHODS: Approved by the authorities, 57 healthy swine (Landrace â€‹× â€‹Piétrain) were randomised to ASCDefib (n 26) or CONVDefib (n 26). Five swine served as sham control. We induced ventricular fibrillation (VF) electrically in anaesthetised swine randomised to ASCDefib or CONVDefib and discontinued mechanical ventilation. After 5 â€‹min of untreated cardiac arrest, we started CPR with mechanical chest compressions and ventilation. We performed transthoracic biphasic defibrillations after 2, 4, 6 and 8 â€‹min CPR targeting 4 â€‹J/kg in either group. Depending on the randomised group, the defibrillation protocol was either three ascending followed by one rectangular waveform (ASCDefib) or three rectangular followed by one ascending waveform (CONVDefib). RESULTS: Under our model-specific conditions, VF was initially terminated by 13/80 ascending waveforms and 13/79 rectangular waveforms and persistent return of spontaneous circulation was achieved in 8/26 (ASCDefib) vs. 10/26 (CONVDefib) animals. Mean current rather than waveform design was predictive for defibrillation success in a generalised linear model. CONCLUSION: Contrary to theoretical assumptions, transthoracic biphasic defibrillation with ascending waveforms is not superior to rectangular waveforms in modelled OHCA. We advocate defibrillation dosage to be guided by current, that has proven its predictive value again. INSTITUTIONAL PROTOCOL NUMBER: 84-02.04.2017.A176.

10.
BMC Surg ; 19(1): 82, 2019 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-31286901

RESUMO

BACKGROUND: An open abdomen is often necessary for survival of patients after peritonitis, compartment syndrome, or in damage control surgery. However, abdominal wall retraction relieves delays and complicates abdominal wall closure. The principle of the newly fascia preserving device (FPD) is the application of anteriorly directed traction on both fascial edges over an external support through a longitudinal beam to relieve increased abdominal pressure and prevent fascial retraction. METHODS: Twelve pigs were randomly divided into two groups. Both groups underwent midline laparotomy under general anesthesia. Group one was treated with the new device, group two served as controls. The tension for closing the abdominal fascia was measured immediately after laparotomy as well as at 24 and 48 h. Vital parameters and ventilation pressure were recorded. Post mortem, all fascial tissues were histologically examined. RESULTS: All pigs demonstrated increases in abdominal circumference. In both groups, forces for closing the abdomen increased over the observation period. Concerning the central closing force after 24 h we saw a significant lower force in the FPD group (14.4 ± 3 N) vs. control group (21.6 ± 5.7 N, p < 0.001). By testing the main effects using an ANOVA analysis we found a significant group related effect concerning closing force and abdominal circumference of the FDP-group vs. control group (p < 0.001; p < 0.001). The placement of the device on chest and pelvis did not influence vital parameters and ventilation pressure. Histologic exam detected no tissue damage. CONCLUSIONS: This trial shows the feasibility to prevent fascial retraction during the open abdomen by using the new device. Thus, it is expected that an earlier closure of the abdominal wall will be possible, and a higher rate of primary closure will be attained.


Assuntos
Parede Abdominal/cirurgia , Fáscia , Laparotomia/instrumentação , Tração/instrumentação , Técnicas de Fechamento de Ferimentos/instrumentação , Animais , Modelos Animais de Doenças , Estudos de Viabilidade , Feminino , Humanos , Estudo de Prova de Conceito , Distribuição Aleatória , Suínos
11.
Ther Hypothermia Temp Manag ; 9(4): 251-257, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30893023

RESUMO

To date, the optimal cooling device for targeted temperature management (TTM) remains unclear. Water-circulating cooling blankets are broadly available and quickly applied but reveal inaccuracy during maintenance and rewarming period. Recently, esophageal heat exchangers (EHEs) have been shown to be easily inserted, revealed effective cooling rates (0.26-1.12°C/h), acceptable deviations from target core temperature (<0.5°C), and rewarming rates between 0.2 and 0.4°C/h. The aim of this study was to compare cooling rates, accuracy during maintenance, and rewarming period as well as side effects of EHEs with water-circulating cooling blankets in a porcine TTM model. Mean core temperature of domestic pigs (n = 16) weighing 83.2 ± 3.6 kg was decreased to a target core temperature of 33°C by either using EHEs or water-circulating cooling blankets. After 8 hours of maintenance, rewarming was started at a goal rate of 0.25°C/h. Mean cooling rates were 1.3 ± 0.1°C/h (EHE) and 3.2 ± 0.5°C/h (blanket, p < 0.0002). Mean difference to target core temperature during maintenance ranged between ±1°C. Mean rewarming rates were 0.21 ± 0.01°C/h (EHE) and 0.22 ± 0.02°C/h (blanket, n.s.). There were no differences with regard to side effects such as brady- or tachycardia, hypo- or hyperkalemia, hypo- or hyperglycemia, hypotension, shivering, or esophageal tissue damage. Target temperature can be achieved faster by water-circulating cooling blankets. EHEs and water-circulating cooling blankets were demonstrated to be reliable and safe cooling devices in a prolonged porcine TTM model with more variability in EHE group.


Assuntos
Hipotermia Induzida/instrumentação , Animais , Esôfago , Hipotermia Induzida/métodos , Suínos
12.
Anesth Analg ; 129(5): 1224-1231, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-30418241

RESUMO

BACKGROUND: Targeted temperature management is a standard therapy for unconscious survivors of cardiac arrest. To date, multiple cooling methods are available including invasive intravascular cooling devices (IVDs), which are widely used in the clinical setting. Recently, esophageal heat exchangers (EHEs) have been developed providing cooling via the esophagus that is located close to the aorta and inferior vena cava. The objective was to compare mean cooling rates, as well as differences, to target temperature during maintenance and the rewarming period of IVD and EHE. METHODS: The study was conducted in 16 female domestic pigs. After randomization to either IVD or EHE (n = 8/group), core body temperature was reduced to 33°C. After 24 hours of maintenance (33°C), animals were rewarmed using a target rate of 0.25°C/h for 10 hours. All cooling phases were steered by a closed-loop feedback system between the internal jugular vein and the chiller. After euthanasia, laryngeal and esophageal tissue was harvested for histopathological examination. RESULTS: Mean cooling rates (4.0°C/h ± 0.4°C/h for IVD and 2.4°C/h ± 0.3°C/h for EHE; P < .0008) and time to target temperature (85.1 ± 9.2 minutes for IVD and 142.0 ± 21.2 minutes for EHE; P = .0008) were different. Mean difference to target temperature during maintenance (0.07°C ± 0.05°C for IVD and 0.08°C ± 0.10°C for EHE; P = .496) and mean rewarming rates (0.2°C/h ± 0.1°C/h for IVD and 0.3°C/h ± 0.2°C/h for EHE; P = .226) were similar. Relevant laryngeal or esophageal tissue damage could not be detected. There were no significant differences in undesired side effects (eg, bradycardia or tachycardia, hypokalemia or hyperkalemia, hypoglycemia or hyperglycemia, hypotension, overcooling, or shivering). CONCLUSIONS: After insertion, target temperatures could be reached faster by IVD compared to EHE. Cooling performance of IVD and EHE did not significantly differ in maintaining target temperature during a targeted temperature management process and in active rewarming protocols according to intensive care unit guidelines in this experimental setting.


Assuntos
Parada Cardíaca/terapia , Hipotermia Induzida/instrumentação , Animais , Temperatura Baixa , Esôfago , Feminino , Hipotermia Induzida/efeitos adversos , Reaquecimento/instrumentação , Suínos
13.
BMC Anesthesiol ; 18(1): 61, 2018 06 05.
Artigo em Inglês | MEDLINE | ID: mdl-29866034

RESUMO

BACKGROUND: Contribution of the small intestine to systemic inflammation after cardiac arrest (CA) is poorly understood. The objective was to evaluate whether an in vivo rat model of 6 min CA is suitable to initiate intestinal ischaemia-reperfusion-injury and to evaluate histomorphological changes and inflammatory processes in the small intestinal mucosa resp. in sera. METHODS: Adult male Wistar rats were subjected to CA followed by cardio-pulmonary resuscitation. Proximal jejunum and serum was collected at 6 h, 24 h, 72 h and 7 d post return of spontaneous circulation (ROSC) and from a control group. The small intestine was evaluated histomorphologically. Cytokine concentrations were measured in jejunum lysates and sera. RESULTS: Histomorphological evaluation revealed a significant increase in mucosal damage in the jejunum at all timepoints compared to controls (p < 0.0001). In jejunal tissues, concentrations of IL-1α, IL-1ß, IL-10, and TNF-α showed significant peaks at 24 h and were 1.5- to 5.7-fold higher than concentrations at 6 h and in the controls (p < 0.05). In serum, a significant higher amount of cytokine was detected only for IL-1ß at 24 h post-ROSC compared to controls (15.78 vs. 9.76 pg/ml). CONCLUSION: CA resulted in mild small intestinal tissue damage but not in systemic inflammation. A rat model of 6 min CA is not capable to comprehensively mimic a post cardiac arrest syndrome (PCAS). Whether there is a vital influence of the intestine on the PCAS still remains unclear.


Assuntos
Modelos Animais de Doenças , Parada Cardíaca/patologia , Mucosa Intestinal/patologia , Intestino Delgado/patologia , Traumatismo por Reperfusão/patologia , Animais , Citocinas/metabolismo , Parada Cardíaca/complicações , Parada Cardíaca/metabolismo , Mucosa Intestinal/metabolismo , Intestino Delgado/metabolismo , Masculino , Ratos , Ratos Wistar , Traumatismo por Reperfusão/etiologia , Traumatismo por Reperfusão/metabolismo , Fatores de Tempo
14.
J Anat ; 232(2): 283-295, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29193065

RESUMO

More frequent utilization of non-heart-beating donor (NHBD) organs for lung transplantation has the potential to relieve the shortage of donor organs. In particular with respect to uncontrolled NHBD, concerns exist regarding the risk of ischaemia/reperfusion (IR) injury-related graft damage or dysfunction. Due to their immunomodulating and tissue-remodelling properties, bone-marrow-derived mesenchymal stem cells (MSCs) have been suspected of playing a beneficial role regarding short- and long-term survival and function of the allograft. Thus, MSC administration might represent a promising pretreatment strategy for NHBD organs. To study the initial effects of warm ischaemia and MSC application, a large animal lung transplantation model was generated, and the structural organ composition of the transplanted lungs was analysed stereologically with particular respect to the blood-gas barrier and the surfactant system. In this study, porcine lungs (n = 5/group) were analysed. Group 1 was the sham-operated control group. In pigs of groups 2-4, cardiac arrest was induced, followed by a period of 3 h of ventilated ischaemia at room temperature. In groups 3 and 4, 50 × 106 MSCs were administered intravascularly via the pulmonary artery and endobronchially, respectively, during the last 10 min of ischaemia. The left lungs were transplanted, followed by a reperfusion period of 4 h. Then, lungs were perfusion-fixed and processed for light and electron microscopy. Samples were analysed stereologically for IR injury-related structural parameters, including volume densities and absolute volumes of parenchyma components, alveolar septum components, intra-alveolar oedema, and the intracellular and intra-alveolar surfactant pool. Additionally, the volume-weighted mean volume of lamellar bodies (lbs) and their profile size distribution were determined. Three hours of ventilated warm ischaemia was tolerated without eliciting histological or ultrastructural signs of IR injury, as revealed by qualitative and quantitative assessment. However, warm ischaemia influenced the surfactant system. The volume-weighted mean volume of lbs was reduced significantly (P = 0.024) in groups subjected to ischaemia (group medians of groups 2-4: 0.180-0.373 µm³) compared with the sham control group (median 0.814 µm³). This was due to a lower number of large lb profiles (size classes 5-15). In contrast, the intra-alveolar surfactant system was not altered significantly. No significant differences were encountered comparing ischaemia alone (group 2) or ischaemia plus application of MSCs (groups 3 and 4) in this short-term model.


Assuntos
Barreira Alveolocapilar/patologia , Transplante de Pulmão/métodos , Pulmão/patologia , Transplante de Células-Tronco Mesenquimais/métodos , Surfactantes Pulmonares , Animais , Modelos Animais de Doenças , Parada Cardíaca , Traumatismo por Reperfusão/patologia , Suínos , Isquemia Quente
15.
J Vasc Surg ; 68(6S): 177S-187S.e1, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-29248244

RESUMO

OBJECTIVE: Despite the clinical success of large-diameter vascular grafts, synthetic grafts in small-diameter vessels are of limited use because of their poor patency rates. Previous experiments of our group provided evidence for good biocompatibility of bacterial nanocellulose (BNC) as a small-vessel graft in the carotid artery in sheep. However, the patency rate of our first-generation tubes after 3 months was only 50%. To advance our concept, we now used modified second-generation tubes with diminished wall thickness and a smoother inner surface to reduce the thrombogenic potential. The aim was to investigate mechanical characteristics of modified second-generation BNC tubes, to evaluate in vivo performance and biocompatibility, and to analyze patency rates. METHODS: We replaced the right carotid artery of 23 sheep with second-generation BNC tubes. Compared with our first-generation tubes, tubes were modified with different surface properties and diminished wall thickness (inner diameter, 4.0-5.0 mm; wall thickness, 1.0-2.5 mm; length, 100 mm) to generate a smoother inner surface with reduced thrombogenic potential and a more porous outer zone, allowing easier cell immigration. RESULTS: At the end of the investigational period, BNC tubes were explanted and grafts were processed for histopathologic analysis. Histologic analysis revealed no acute signs of foreign body reaction such as immigration of giant cells or other acute inflammatory reaction and therefore provided evidence for good biocompatibility of the second-generation tubes. However, all grafts of the sheep without antiplatelet therapy were occluded after 9 months, whereas grafts in sheep receiving dual platelet inhibition showed a patency rate of 67% (six of nine grafts). Further modified grafts revealed a patency rate of 80% (four of five grafts remained open). CONCLUSIONS: Patency rates of the second-generation tubes could be substantially improved compared with our first-generation tubes. However, poor patency rates of tissue-engineered blood vessels still limit their use in clinical studies. Further efforts in terms of in vitro and in vivo studies are essential to improve grafts of BNC.


Assuntos
Materiais Biocompatíveis , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Artérias Carótidas/cirurgia , Celulose/química , Nanopartículas , Polissacarídeos Bacterianos/química , Grau de Desobstrução Vascular , Animais , Artérias Carótidas/efeitos dos fármacos , Artérias Carótidas/patologia , Artérias Carótidas/fisiopatologia , Oclusão de Enxerto Vascular/patologia , Oclusão de Enxerto Vascular/fisiopatologia , Oclusão de Enxerto Vascular/prevenção & controle , Teste de Materiais , Modelos Animais , Inibidores da Agregação Plaquetária/farmacologia , Porosidade , Desenho de Prótese , Falha de Prótese , Carneiro Doméstico , Propriedades de Superfície , Trombose/patologia , Trombose/fisiopatologia , Trombose/prevenção & controle , Fatores de Tempo , Grau de Desobstrução Vascular/efeitos dos fármacos
16.
PLoS One ; 12(3): e0173229, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28291783

RESUMO

BACKGROUND: Targeted temperature management (TTM) is widely used in critical care settings for conditions including hepatic encephalopathy, hypoxic ischemic encephalopathy, meningitis, myocardial infarction, paediatric cardiac arrest, spinal cord injury, traumatic brain injury, ischemic stroke and sepsis. Furthermore, TTM is a key treatment for patients after out-of-hospital cardiac-arrest (OHCA). However, the optimal cooling method, which is quick, safe and cost-effective still remains controversial. Since the oesophagus is adjacent to heart and aorta, fast heat-convection to the central blood-stream could be achieved with a minimally invasive oesophageal heat exchanger (OHE). To date, the optimal diameter of an OHE is still unknown. While larger diameters may cause thermal- or pressure-related tissue damage after long-term exposure to the oesophageal wall, smaller diameter (e.g., gastric tubes, up to 11mm) may not provide effective cooling rates. Thus, the objective of the study was to compare OHE-diameters of 11mm (OHE11) and 14.7mm (OHE14.7) and their effects on tissue and cooling capability. METHODS: Pigs were randomized to OHE11 (N = 8) or OHE14.7 (N = 8). After cooling, pigs were maintained at 33°C for 1 hour. After 10h rewarming, oesophagi were analyzed by means of histopathology. The oesophagus of four animals from a separate study that underwent exactly the identical preparation and cooling protocol described above but received a maintenance period of 24h were used as histopathological controls. RESULTS: Mean cooling rates were 2.8±0.4°C°C/h (OHE11) and 3.0±0.3°C °C/h (OHE14.7; p = 0.20). Occasional mild acute inflammatory transepithelial infiltrates were found in the cranial segment of the oesophagus in all groups including controls. Deviations from target temperature were 0.1±0.4°C (OHE11) and 0±0.1°C (OHE14.7; p = 0.91). Rewarming rates were 0.19±0.07°C °C/h (OHE11) and 0.20±0.05°C °C/h (OHE14.7; p = 0.75). CONCLUSIONS: OHE with diameters of 11 mm and 14.7 mm achieve effective cooling rates for TTM and did not cause any relevant oesophageal tissue damage. Both OHE demonstrated acceptable deviations from target temperature and allowed for an intended rewarming rate (0.25°C/h).


Assuntos
Temperatura Corporal , Temperatura Baixa , Esôfago/fisiopatologia , Temperatura Alta , Animais , Feminino , Suínos
17.
PLoS One ; 11(3): e0150759, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26938613

RESUMO

Hypothermia is a severe, unpleasant side effect during general anesthesia. Thus, temperature surveillance is a prerequisite in general anesthesia settings during experimental surgeries. The gold standard to measure the core body temperature (Tcore) is placement of a Swan-Ganz catheter in the pulmonary artery, which is a highly invasive procedure. Therefore, Tcore is commonly examined in the urine bladder and rectum. However, these procedures are known for their inaccuracy and delayed record of temperatures. Zero-heat-flux (ZHF) thermometry is an alternative, non-invasive method quantifying Tcore in human patients by applying a thermosensoric patch to the lateral forehead. Since the porcine cranial anatomy is different to the human's, the optimal location of the patch remains unclear to date. The aim was to compare three different patch locations of ZHF thermometry in a porcine hypothermia model. Hypothermia (33.0 °C Tcore) was conducted in 11 anesthetized female pigs (26-30 kg). Tcore was measured continuously by an invasive Swan-Ganz catheter in the pulmonary artery (Tpulm). A ZHF thermometry device was mounted on three different defined locations. The smallest average difference between Tpulm and TZHF during stable temperatures was 0.21 ± 0.16 °C at location A, where the patch was placed directly behind the eye. Also during rapidly changing temperatures location A showed the smallest bias with 0.48 ± 0.29 °C. Location A provided the most reliable data for Tcore. Therefore, the ZHF thermometry patch should be placed directly behind the left temporal corner of the eye to provide a non-invasive method for accurate measurement of Tcore in pigs.


Assuntos
Temperatura Corporal , Termometria/métodos , Analgesia , Anestesia , Animais , Cateterismo , Cateterismo de Swan-Ganz , Modelos Animais de Doenças , Feminino , Testa/patologia , Hipotermia/patologia , Artéria Pulmonar , Sus scrofa , Termômetros
19.
Dis Model Mech ; 8(4): 403-15, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25713297

RESUMO

Recent studies have revealed an important role for LTBP-4 in elastogenesis. Its mutational inactivation in humans causes autosomal recessive cutis laxa type 1C (ARCL1C), which is a severe disorder caused by defects of the elastic fiber network. Although the human gene involved in ARCL1C has been discovered based on similar elastic fiber abnormalities exhibited by mice lacking the short Ltbp-4 isoform (Ltbp4S(-/-)), the murine phenotype does not replicate ARCL1C. We therefore inactivated both Ltbp-4 isoforms in the mouse germline to model ARCL1C. Comparative analysis of Ltbp4S(-/-) and Ltbp4-null (Ltbp4(-/-)) mice identified Ltbp-4L as an important factor for elastogenesis and postnatal survival, and showed that it has distinct tissue expression patterns and specific molecular functions. We identified fibulin-4 as a previously unknown interaction partner of both Ltbp-4 isoforms and demonstrated that at least Ltbp-4L expression is essential for incorporation of fibulin-4 into the extracellular matrix (ECM). Overall, our results contribute to the current understanding of elastogenesis and provide an animal model of ARCL1C.


Assuntos
Cútis Laxa/genética , Cútis Laxa/patologia , Genes Recessivos , Proteínas de Ligação a TGF-beta Latente/genética , Animais , Animais Recém-Nascidos , Aorta/anormalidades , Aorta/patologia , Cardiomegalia/complicações , Cardiomegalia/patologia , Tecido Elástico/metabolismo , Elastina/metabolismo , Matriz Extracelular/metabolismo , Proteínas da Matriz Extracelular/metabolismo , Feminino , Inativação Gênica , Glicosilação , Ventrículos do Coração/patologia , Humanos , Proteínas de Ligação a TGF-beta Latente/química , Proteínas de Ligação a TGF-beta Latente/deficiência , Proteínas de Ligação a TGF-beta Latente/metabolismo , Pulmão/anormalidades , Pulmão/patologia , Camundongos Endogâmicos C57BL , Modelos Biológicos , Ligação Proteica , Isoformas de Proteínas/química , Isoformas de Proteínas/deficiência , Isoformas de Proteínas/genética , Isoformas de Proteínas/metabolismo , Pele/patologia , Redução de Peso
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA