Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 12(1): 10859, 2022 06 27.
Artigo em Inglês | MEDLINE | ID: mdl-35760855

RESUMO

Analysis of stool offers simple, non-invasive monitoring for many gastrointestinal (GI) diseases and access to the gut microbiome, however adherence to stool sampling protocols remains a major challenge because of the prevalent dislike of handling one's feces. We present a technology that enables individual stool specimen collection from toilet wastewater for fecal protein and molecular assay. Human stool specimens and a benchtop test platform integrated with a commercial toilet were used to demonstrate reliable specimen collection over a wide range of stool consistencies by solid/liquid separation followed by spray-erosion. The obtained fecal suspensions were used to perform occult blood tests for GI cancer screening and for microbiome 16S rRNA analysis. Using occult blood home test kits, we found overall 90% agreement with standard sampling, 96% sensitivity and 86% specificity. Microbiome analysis revealed no significant difference in within-sample species diversity compared to standard sampling and specimen cross-contamination was below the detection limit of the assay. Furthermore, we report on the use of an analogue turbidity sensor to assess in real time loose stools for tracking of diarrhea. Implementation of this technology in residential settings will improve the quality of GI healthcare by facilitating increased adherence to routine stool monitoring.


Assuntos
Microbioma Gastrointestinal , Sangue Oculto , Fezes , Microbioma Gastrointestinal/genética , Humanos , RNA Ribossômico 16S/genética , Manejo de Espécimes/métodos
2.
Sci Total Environ ; 835: 155401, 2022 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-35469858

RESUMO

Wastewater-based SARS-CoV-2 surveillance on college campuses has the ability to detect individual clinical COVID-19 cases at the building-level. High concordance of wastewater results and clinical cases has been observed when calculated over a time window of four days or longer and in settings with high incidence of infection. At Duke University, twice a week clinical surveillance of all resident undergraduates was carried out in the spring 2021 semester. We conducted simultaneous wastewater surveillance with daily frequency on selected residence halls to assess wastewater as an early warning tool during times of low transmission with the hope of scaling down clinical test frequency. We evaluated the temporal relationship of the two time-dense data sets, wastewater and clinical, and sought a strategy to achieve the highest wastewater predictive values using the shortest time window to enable timely intervention. There were 11 days with clinical cases in the residence halls (80-120 occupants) under wastewater surveillance with 5 instances of a single clinical case and 3 instances of two clinical cases which also corresponded to a positive wastewater SARS-CoV-2 signal. While the majority (71%) of our wastewater samples were negative for SARS-CoV-2, 29% resulted in at least one positive PCR signal, some of which did not correlate with an identified clinical case. Using a criteria of two consecutive days of positive wastewater signals, we obtained a positive predictive value (PPV) of 75% and a negative predictive value of 87% using a short 2 day time window for agreement. A conventional concordance over a much longer 4 day time window resulted in PPV of only 60%. Our data indicated that daily wastewater collection and using a criteria of two consecutive days of positive wastewater signals was the most predictive approach to timely early warning of COVID-19 cases at the building level.


Assuntos
COVID-19 , SARS-CoV-2 , COVID-19/epidemiologia , Humanos , Universidades , Águas Residuárias , Vigilância Epidemiológica Baseada em Águas Residuárias
3.
Anal Chem ; 93(33): 11357-11363, 2021 08 24.
Artigo em Inglês | MEDLINE | ID: mdl-34370439

RESUMO

In 1938, Walker Bleakney and John A. Hipple first described the cycloidal mass analyzer as the only mass analyzer configuration capable of "perfect" ion focusing. Why has their geometry been largely neglected for many years and how might it earn a respectable place in the world of modern chemical analysis? This Perspective explores the properties of the cycloidal mass analyzer and identifies the lack of suitable ion array detectors as a significant reason why cycloidal mass analyzers are not widely used. The recent development of capacitive transimpedance amplifier array detectors can enable several techniques using cycloidal mass analyzers including spatially coded apertures and single particle mass analysis with a "virtual-slit", helping the cycloidal mass analyzer earn a respectable place in chemical analysis.


Assuntos
Amplificadores Eletrônicos
4.
J Am Soc Mass Spectrom ; 32(2): 509-518, 2021 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-33382610

RESUMO

Cycloidal sector mass analyzers have, in principle, perfect focusing due to perpendicularly oriented uniform electric and magnetic fields, making them ideal candidates for incorporation of spatially coded apertures. We have previously demonstrated a proof-of-concept cycloidal-coded aperture miniature mass spectrometer (C-CAMMS) instrument and achieved a greater than 10-fold increase in throughput without sacrificing resolution, compared with a single slit instrument. However, artifacts were observed in the reconstructed mass spectrum due to nonuniformity in the electric field and misalignment of the detector and the ion source with the mass analyzer focal plane. In this work, we modified the mass analyzer design of the previous C-CAMMS instrument to improve electric field uniformity, improve the alignment of the ion source and the mass analyzer with the detector, and increase the depth-of-focus to further facilitate alignment. A comparison of reconstructed spectra of a mixture of dry air and toluene at different electric fields was performed using the improved C-CAMMS prototype. A reduction in reconstruction artifacts compared to our proof-of-concept C-CAMMS instrument highlights the improved performance enabled by the design changes.

5.
Environ Sci Technol ; 54(24): 16147-16155, 2020 12 15.
Artigo em Inglês | MEDLINE | ID: mdl-33269914

RESUMO

Providing safe and reliable sanitation services to the billions of people currently lacking them will require a multiplicity of approaches. Improving onsite wastewater treatment to standards enabling water reuse would reduce the need to transport waste and fresh water over long distances. Here, we describe a compact, automated system designed to treat the liquid fraction of blackwater for onsite water reuse that combines cross-flow ultrafiltration, activated carbon, and electrochemical oxidation. In laboratory testing, the system consistently produces effluent with 6 ≤ pH ≤ 9, total suspended solids (TSS) < 30 mg L-1, and chemical oxygen demand (COD) < 150 mg L-1. These effluent parameters were achieved across a wide range of values for influent TSS (61-820 mg L-1) and COD (384-1505 mg L-1), demonstrating a robust system for treating wastewater of varying strengths. A preliminary techno-economic analysis (TEA) was conducted to elucidate primary cost drivers and prioritize research and development pathways toward commercial feasibility. The ultrafiltration system is the primary cost driver, contributing to >50% of both the energy and maintenance costs. Several scenario parameters showed an outsized impact on costs relative to technology parameters. Specific technological improvements for future prototype development are discussed.


Assuntos
Eliminação de Resíduos Líquidos , Purificação da Água , Análise da Demanda Biológica de Oxigênio , Humanos , Laboratórios , Águas Residuárias
6.
Sci Total Environ ; 730: 138957, 2020 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-32402964

RESUMO

A challenge in water reuse for toilet flushing in India and other Asian countries derives from pour flushing practices. It is a common assumption that the amount of pour flushed water used for personal cleansing is small in comparison to the cistern flush volume, however there is a knowledge gap regarding the actual contribution of each water source to the blackwater amount. In this study, digital water meters were used to measure the fraction of water from personal wash tap relative to cistern water that is used for toilet flushing. High temporal resolution measurements were carried in three different urban sites in the city of Coimbatore in the southern Indian state of Tamil Nadu where onsite sanitation treatment prototypes that may provide reclaimed water for cistern flushing are being tested. Data collected over periods of up to 2 months show that the contribution of the cistern flush to the total blackwater volume is low (14-40%). These data highlight an important factor to inform interventions designed around water reuse for flushing in world geographies where personal toilet cleansing by water is the common practice.

7.
Sci Total Environ ; 713: 136706, 2020 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-32019042

RESUMO

4.2 billion people live without access to safely managed sanitation services. This report describes the field testing of an onsite prototype system designed to treat blackwater from a single flush toilet and reuse of the treated effluent for flushing. The system passes wastewater through a solid-liquid separator followed by settling tanks and granular activated carbon columns into an electrochemical reactor that oxidizes chloride salts from urine to generate chlorine to remove pathogens. The objectives of the study were to verify the functionality of the system (previously demonstrated in the laboratory) under realistic use conditions, to identify maintenance requirements, and to make a preliminary assessment of the system's user acceptability. The prototype was installed in a women's workplace and residential toilet block in Coimbatore, India, and tested over a period of 10 months. The treated water met stringent disinfection threshold for both E. coli and helminth eggs and produced a clear, colorless effluent that met or nearly met local and international discharge standards for non-sewered sanitation systems. The effluent had an average chemical oxygen demand of 81 mg/L, total suspended solids of 11 mg/L, and reduction of total nitrogen by 65%. These tests determined the recommended service lifetimes and maintenance intervals for key system components including the electrochemical cell, granular activated carbon columns, and solid-liquid separator. User feedback regarding the use of treated blackwater as flush water was positive. These findings will inform the design and implementation of next-generation systems currently under development.

8.
Sci Total Environ ; 703: 135469, 2020 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-31732183

RESUMO

Innovations that enable cost-effective and resource-conserving treatment of human waste are required for the 4.2 billion people in the world who currently lack safe and reliable sanitation services. Onsite treatment and reuse of blackwater is one strategy towards this end, greatly reducing the need to transport wastewater over long distances either via sewers or trucks. Here, we report on the field testing of a prototype onsite blackwater treatment system conducted over a period of 8 months. The system was connected to a women's toilet in a public communal ablution block located in an informal settlement near Durban, South Africa. Liquid waste was treated by separation and diversion of large solids, settling of suspended solids, and filtration through activated carbon prior to disinfection by electrochemical oxidation. System performance was monitored daily by measurement of chemical and physical water quality parameters onsite and confirmed by periodic detailed analysis of chemical and biological parameters at an offsite lab. Daily monitoring of system performance indicated that the effluent had minimal color and turbidity (maximum 90 Pt/Co units and 6.48 NTU, respectively), and consistent evolution of chlorine as blackwater passed through the system. Weekly offsite analysis confirmed that the system consistently inactivated pathogens (E. coli and coliforms) and reduced chemical oxygen demand and total suspended solids to meet ISO 30500 category B standards. Significant reductions in total nitrogen load were also observed, though these reductions often fell short of the 70% reduction required by ISO 30500. No significant reduction in total phosphorus was observed. Maintenance requirements were identified, and the resilience of the system to restart following a prolonged shutdown was demonstrated, but significant improvements are required in the design of the solid/liquid separation mechanism for application of this system in a wiping culture.


Assuntos
Características da Família , Eliminação de Resíduos Líquidos/métodos , África do Sul , Águas Residuárias
9.
Gates Open Res ; 3: 1176, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31508581

RESUMO

Background: There is an unmet demand for community-scale fecal sludge treatment units (FSTUs) that serve communities of between 1,000 and 50,000 people and are able to operate in non-sewered and off-grid environments. An emerging industry standard for FSTUs includes as a key criteria energy independence in steady-state. Theoretically, there is sufficient thermal energy available in fecal sludge to provide the electrical power needed to run the FSTU. However, such a system had never been implemented. Methods: Biomass Controls has previously demonstrated the thermal treatment of fecal sludge using the Biogenic Refinery, a thermal FSTU deployed in three sites in India. In this article we describe testing where a Biogenic Refinery was paired with a thermal fluid heat exchanger and organic Rankine cycle generator to generate electrical power. Results: This Biogenic Refinery combined heat and power system generated sufficient electrical power to offset electrical parasitic loads in steady-state operation and produce a surplus of 1.2 kWe. Conclusions: The results of the study demonstrate that there is an excess of energy available and reliable mechanisms to generate electrical energy using an FSTU. Additional steps are necessary to transition to a true off-grid FSTU.

10.
Water Environ J ; 33(1): 61-66, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31007708

RESUMO

Our research is focused on the development of decentralized waste water treatment technologies enabling onsite water reuse. Accumulation of solids with recycling of treated blackwater increases the energy required for disinfection with an electrochemical process. We hypothesized that improving the preprocess settling of blackwater by increasing the tortuosity of the liquid flow path would reduce this energy demand by reducing particle-associated chemical oxygen demand (COD). This approach successfully reduced the total suspended solids and turbidity in the process liquid accumulated per user-day equivalent. A modest reduction in the apparent steady-state accumulation of COD was also observed, likely because of the retention of COD associated with larger particles in the settling tanks. Interestingly, these improvements did not improve the energy efficiency of the electrochemical disinfection process, as predicted. These observations suggest that improving the energy efficiency of electrochemical disinfection will require remediation of dissolved COD.

11.
J Appl Electrochem ; 49(5): 443-453, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31031416

RESUMO

ABSTRACT: We report the development of novel modes of operation for electrochemical disinfection of E. coli in human urine simulant with an aim to minimize the energy required for disinfection. The system employs boron-doped diamond electrodes and will be part of an energy neutral, water and additive free outdoor toilet being developed for use in developing countries. Disinfection had been previously demonstrated with voltage being continuously applied to the electrode until disinfection was achieved. In the present study, a new pulsed mode of operation is investigated. This includes a continuous on mode, where oxidants are generated until disinfection is achieved, a single cycle mode, where oxidants are generated for a fixed time and the water is circulated so allow already generated oxidants to disinfect, and a pulsed mode with different duty cycles, which is like the single cycle mode but with multiple cycles. Disinfection was achieved with pulsed mode operation with a 68% energy reduction compared to the continuous on mode. Energy saving was most likely achieved by lengthening the contact time of the disinfectant with the bacteria and increased generation of non-chlorine disinfecting oxidants.

12.
Gates Open Res ; 3: 559, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-32494770

RESUMO

The aims of the Reinvent the Toilet Challenge (RTTC) include creation of an off-the-grid sanitation system with operating costs of less than US$0.05 per user per day. Because of the small scale at which many reinvented toilets (RT) are intended to operate, non-biological treatment has been generally favored. The RTTC has already instigated notable technological advances in non-sewered sanitation systems (NSSS). However, increasingly stringent liquid effluent standards for N and P could limit the deployment of current RT in real-world scenarios, despite the urgent need for these systems. The newly adopted ISO 30500 standards for water reuse in NSSS dictate minimal use of chemical/biological additives, while at the same time requiring a 70% and 80% reduction in total nitrogen and phosphorus, respectively. This document provides a brief overview of the mature and emerging technologies for N and P (specifically ammonia/ammonium and orthophosphate) removal from wastewater. At present, the dearth of nutrient removal methods proven to be effective at small scales is a significant barrier to meeting ISO 30500 standards. Closing the gap between RTs and ISO 30500 will require significant investments in basic R&D of emerging technologies for non-biological N and P remediation and/or increased reliance on biological processes. Adaptation of existing nutrient-removal technologies to small-scale NSSS is a viable option that merits additional investigation.

13.
Water Res ; 144: 553-560, 2018 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-30077914

RESUMO

Over 1/3 of the global population lacks access to improved sanitation, leading to disease, death, and impaired economic development. Our group is working to develop rapidly deployable, cost-effective, and sustainable solutions to this global problem that do not require significant investments in infrastructure. Previously, we demonstrated the feasibility of a toilet system that recycles blackwater for onsite reuse as flush water, in which the blackwater is electrochemically treated to remove pathogens due to fecal contamination. However, this process requires considerable energy (48-93 kJ/L) to achieve complete disinfection of the process liquid, and the disinfected liquid retains color and chemical oxygen demand (COD) in excess of local discharge standards, negatively impacting user acceptability. Granular activated carbon (GAC) efficiently reduces COD in concentrated wastewaters. We hypothesized that reduction of COD with GAC prior to electrochemical treatment would both improve disinfection energy efficiency and user acceptability of the treated liquid. Here we describe the development and testing of a hybrid system that combines these technologies and demonstrate its ability to achieve full disinfection with improved energy efficiency and liquid quality more suitable for onsite reuse and/or discharge.


Assuntos
Técnicas Eletroquímicas/métodos , Eliminação de Resíduos Líquidos/instrumentação , Eliminação de Resíduos Líquidos/métodos , Aparelho Sanitário , Análise da Demanda Biológica de Oxigênio , Carvão Vegetal/química , Desinfecção/métodos , Técnicas Eletroquímicas/instrumentação , Desenho de Equipamento , Reciclagem , Águas Residuárias/química , Águas Residuárias/microbiologia , Purificação da Água/instrumentação , Purificação da Água/métodos
14.
Gates Open Res ; 2: 50, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30706055

RESUMO

Onsite reuse of blackwater requires removal of considerable amounts of suspended solids and organic material in addition to inactivation of pathogens. Previously, we showed that electrochemical treatment could be used for effective pathogen inactivation in blackwater, but was inadequate to remove solids and organics to emerging industry standards. Further, we found that as solids and organics accumulate with repeated recycling, electrochemical treatment becomes less energetically sustainable. Here, we describe a pilot study in which concentrated blackwater is pretreated with ultrafiltration and granular activated carbon prior to electrochemical disinfection, and show that this combination of treatments removes 75-99% of chemical oxygen demand, 92-100% of total suspended solids, and improves the energy efficiency of electrochemical blackwater treatment by an order of magnitude.

15.
J Am Soc Mass Spectrom ; 29(2): 360-372, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29052038

RESUMO

Despite many potential applications, miniature mass spectrometers have had limited adoption in the field due to the tradeoff between throughput and resolution that limits their performance relative to laboratory instruments. Recently, a solution to this tradeoff has been demonstrated by using spatially coded apertures in magnetic sector mass spectrometers, enabling throughput and signal-to-background improvements of greater than an order of magnitude with no loss of resolution. This paper describes a proof of concept demonstration of a cycloidal coded aperture miniature mass spectrometer (C-CAMMS) demonstrating use of spatially coded apertures in a cycloidal sector mass analyzer for the first time. C-CAMMS also incorporates a miniature carbon nanotube (CNT) field emission electron ionization source and a capacitive transimpedance amplifier (CTIA) ion array detector. Results confirm the cycloidal mass analyzer's compatibility with aperture coding. A >10× increase in throughput was achieved without loss of resolution compared with a single slit instrument. Several areas where additional improvement can be realized are identified. Graphical Abstract ᅟ.

16.
Water Environ J ; 31(4): 545-551, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-29242713

RESUMO

Decentralized, energy-efficient waste water treatment technologies enabling water reuse are needed to sustainably address sanitation needs in water- and energy-scarce environments. Here, we describe the effects of repeated recycling of disinfected blackwater (as flush liquid) on the energy required to achieve full disinfection with an electrochemical process in a prototype toilet system. The recycled liquid rapidly reached a steady state with total solids reliably ranging between 0.50 and 0.65% and conductivity between 20 and 23 mS/cm through many flush cycles over 15 weeks. The increase in accumulated solids was associated with increased energy demand and wide variation in the free chlorine contact time required to achieve complete disinfection. Further studies on the system at steady state revealed that running at higher voltage modestly improves energy efficiency, and established running parameters that reliably achieve disinfection at fixed run times. These results will guide prototype testing in the field.

17.
ACS Appl Mater Interfaces ; 9(19): 16610-16619, 2017 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-28471651

RESUMO

This work investigates the surface chemistry of H2O2 generation on a boron-doped ultrananocrystalline diamond (BD-UNCD) electrode. It is motivated by the need to efficiently disinfect liquid waste in resource constrained environments with limited electrical power. X-ray photoelectron spectroscopy was used to identify functional groups on the BD-UNCD electrode surfaces while the electrochemical potentials of generation for these functional groups were determined via cyclic voltammetry, chronocoulometry, and chronoamperometry. A colorimetric technique was employed to determine the concentration and current efficiency of H2O2 produced at different potentials. Results showed that preanodization of an as-grown BD-UNCD electrode can enhance the production of H2O2 in a strong acidic environment (pH 0.5) at reductive potentials. It is proposed that the electrogeneration of functional groups at oxidative potentials during preanodization allows for an increased current density during the successive electrolysis at reductive potentials that correlates to an enhanced production of H2O2. Through potential cycling methods, and by optimizing the applied potentials and duty cycle, the functional groups can be stabilized allowing continuous production of H2O2 more efficiently compared to static potential methods.

18.
Annu Rev Anal Chem (Palo Alto Calif) ; 10(1): 141-156, 2017 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-28301752

RESUMO

The use of coded apertures in mass spectrometry can break the trade-off between throughput and resolution that has historically plagued conventional instruments. Despite their very early stage of development, coded apertures have been shown to increase throughput by more than one order of magnitude, with no loss in resolution in a simple 90-degree magnetic sector. This enhanced throughput can increase the signal level with respect to the underlying noise, thereby significantly improving sensitivity to low concentrations of analyte. Simultaneous resolution can be maintained, preventing any decrease in selectivity. Both one- and two-dimensional (2D) codes have been demonstrated. A 2D code can provide increased measurement diversity and therefore improved numerical conditioning of the mass spectrum that is reconstructed from the coded signal. This review discusses the state of development, the applications where coding is expected to provide added value, and the various instrument modifications necessary to implement coded apertures in mass spectrometers.

19.
Adv Sci (Weinh) ; 2(10): 1500203, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27812457

RESUMO

A mentoring guide for incoming graduate students has been developed to minimize the time spent reiterating general guidance and "norms" that need to be instilled in new graduate students. This allows principal investigators and senior researchers to provide high value, customized coaching for the individual student which is where the real value of the PhD education is expressed.

20.
J Am Soc Mass Spectrom ; 26(11): 1903-10, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26133527

RESUMO

A novel chemical ionization (CI) source has been developed based on a carbon nanotube (CNT) field emission electron source. The CNT-based electron source was evaluated and compared with a standard filament thermionic electron source in a commercial explosives trace detection desktop mass spectrometer. This work demonstrates the first reported use of a CNT-based ion source capable of collecting CI mass spectra. Both positive and negative modes were investigated. Spectra were collected for a standard mass spectrometer calibration compound, perfluorotributylamine (PFTBA), as well as trace explosives including trinitrotoluene (TNT), Research Department explosive (RDX), and pentaerythritol tetranitrate (PETN). The electrical characteristics, lifetime at operating pressure, and power requirements of the CNT-based electron source are reported. The CNT field emission electron sources demonstrated an average lifetime of 320 h when operated in constant emission mode under elevated CI pressures. The ability of the CNT field emission source to cycle on and off can provide enhanced lifetime and reduced power consumption without sacrificing performance and detection capabilities. Graphical Abstract ᅟ.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA