Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Med Phys ; 2024 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-39092902

RESUMO

BACKGROUND: Ultrahigh dose-rate radiation (UHDR) produces less hydrogen peroxide (H2O2) in pure water, as suggested by some experimental studies, and is used as an argument for the validity of the theory that FLASH spares the normal tissue due to less reactive oxygen species (ROS) production. In contrast, most Monte Carlo simulation studies suggest the opposite. PURPOSE: We aim to unveil the effect of UHDR on H2O2 production in pure water and its underlying mechanism, to serve as a benchmark for Monte Carlo simulation. We hypothesized that the reaction of solvated electrons ( e aq - ${\mathrm{e}}_{{\mathrm{aq}}}^ - $ ) removing hydroxyl radicals (•OH), the precursor of H2O2, is the reason why UHDR leads to a lower G-value (molecules/100 eV) for H2O2 (G[H2O2]), because: 1, the third-order reaction between e aq - ${\mathrm{e}}_{{\mathrm{aq}}}^ - $ and •OH is more sensitive to increased instantaneous ROS concentration by UHDR than a two-order reaction of •OH self-reaction producing H2O2; 2, e aq - ${\mathrm{e}}_{{\mathrm{aq}}}^ - $ has two times higher diffusion coefficient and higher reaction rate constant than that of •OH, which means e aq - ${\mathrm{e}}_{{\mathrm{aq}}}^ - $ would dominate the competition for •OH and benefit more from the inter-track effect of UHDR. Meanwhile, we also experimentally verify the theory of long-lived radicals causing lower G(H2O2) in conventional irradiation, which is mentioned in some simulation studies. METHODS AND MATERIALS: H2O2 was measured by Amplex UltraRed assay. 430.1 MeV/u carbon ions (50 and 0.1 Gy/s), 9 MeV electrons (600 and 0.62 Gy/s), and 200 kV x-ray tube (10 and 0.1 Gy/s) were employed. For three kinds of water (real hypoxic: 1% O2; hypoxic: 1% O2 and 5% CO2; and normoxic: 21% O2), unbubbled and bubbled samples with N2O, the scavenger of e aq - ${\mathrm{e}}_{{\mathrm{aq}}}^ - $ , were irradiated by carbon ions and electrons with conventional and UHDR at different absolute dose levels. Normoxic water dissolved with sodium nitrate (NaNO3), another scavenger of e aq - ${\mathrm{e}}_{{\mathrm{aq}}}^ - $ , and bubbled with N2O was irradiated by x-ray to verify the results of low-LET electron beam. RESULTS: UHDR leads to a lower G(H2O2) than conventional irradiation. O2 and CO2 can both increase G(H2O2). N2O increases G(H2O2) of both UHDR and conventional irradiation and eliminates the difference between them for carbon ions. However, N2O decreases G(H2O2) in electron conventional irradiation but increases G(H2O2) in the case of UHDR, ending up with no dose-rate dependency of G(H2O2). Three-spilled carbon UHDR does not have a lower G(H2O2) than one-spilled UHDR. However, the electron beam shows a lower G(H2O2) for three-spilled UHDR than for one-spilled UHDR. Normoxic water with N2O or NaNO3 can both eliminate the dose rate dependency of H2O2 production for x-ray. CONCLUSIONS: UHDR has a lower G(H2O2) than the conventional irradiation for both high LET carbon and low LET electron and x-ray beams. Both scavengers for e aq - ${\mathrm{e}}_{{\mathrm{aq}}}^ - $ , N2O and NaNO3, eliminate the dose-rate dependency of G(H2O2), which suggests e aq - ${\mathrm{e}}_{{\mathrm{aq}}}^ - $ is the reason for decreased G(H2O2) for UHDR. Three-spilled UHDR versus one-spilled UHDR indicates that the assumption of residual radicals reducing G(H2O2) of conventional irradiation may only be valid for low LET electron beam.

2.
Appl Opt ; 63(10): 2578-2586, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38568539

RESUMO

With the improvement of quality requirements of optical components, the detection of subsurface defects of optical components has become a key technology. The existing detection methods still have some limitations in detection depth and detection efficiency. In this paper, a defect scattering light collection method based on ellipsoidal mirror model is used to analyze the scattering light collection efficiency under different experimental conditions theoretically, and the favorable conditions for improving the scattering light collection are proposed. After simulation verification, the use of ellipsoidal reflectors to collect scattered light can effectively avoid the impact of surface defects compared to lenses. At the same time, an experimental system based on this method is set up to filter the stray light by mean filtering method. The system detected three scratches (2 µm in width and 252 nm in depth) on the underside of a piece of quartz glass. The results show that the system can clearly detect the subsurface defects of optical components.

3.
Rev Sci Instrum ; 95(3)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38426900

RESUMO

The key feature of non-contact temperature measurement provided by infrared (IR) cameras underpins their versatility. However, the accuracy of temperature measurements with IR cameras depends on imaging quality due to their non-contact nature, such as the lens, body temperature, and measurement environment. This paper addresses the correction of radial distortion and nonlinear response issues in IR cameras. To address radial distortion, we have designed a passive checkerboard calibration board specifically for infrared cameras. This board is used to calibrate the IR camera and derive the necessary camera parameters. Subsequently, these parameters are applied during the actual measurement process to rectify radial distortion effectively. Building on the radial distortion correction method mentioned above, we propose a multi-point segmented calibration approach that considers different temperature ranges and imaging regions. This method alleviates the issue of reduced temperature measurement accuracy due to variations in camera responses by computing gain and offset coefficient matrices for each temperature range. Experimental results demonstrate the effectiveness of the calibration board in correcting radial distortion in IR cameras, with a mean reprojection error of less than 0.16 pixels. Regarding the nonlinear response problem, the introduced method significantly reduces the relative error in temperature measurement. In the verification phase, spanning from 100 to 500 °C, the average relative error in temperature measurement decreases by 0.49% from 1.61% before and after correction, which highlights a substantial improvement in temperature measurement accuracy. This work gives a useful reference to improve the imaging quality and temperature measurement accuracy using infrared cameras.

4.
Rev Sci Instrum ; 94(12)2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-38088782

RESUMO

A photothermal vortex interferometer (PTVI) is proposed to fill the gap of full-field measurement of the laser-induced nanoscale thermal lens dynamics of optical elements. The PTVI produces a multi-ring petal-like interferogram by the coaxial coherent superposition of the high-order conjugated Laguerre-Gaussian beams. The non-uniform optical path change (OPC) profile resulting from the thermal lens causes the petals of the interferogram at the different radii to shift by the different azimuths. To demodulate such an interferogram, an azimuthal complex spectra analysis is presented by using a camera with a pixelated multi-ring pattern written on its sensor to extract multiple azimuthal intensity profiles synchronously from the interferogram. Therefore, the OPC profile can be determined dynamically from the complex spectra of the azimuthal intensity profiles at the main frequency components. An analytical thermophysical model of the thermal lens is given, and the basic principle of the azimuthal complex spectra analysis is revealed. A proof-of-concept experiment is demonstrated using a N-BK7 glass sample heated by a pump laser. The results verified that the PTVI achieves the measurement accuracy of 47 pm with a standard deviation of 358 pm (3σ) and can be used for full-field measurement of the nanoscale OPC profile caused by the thermal lens dynamics. Due to the picometer-scale accuracy of the PTVI, the absorption coefficient and thermal diffusivity of the glass sample were determined to be A0 = 0.126 m-1 and D = 5.63 × 10-7 m2 s-1, respectively, which agree with the nominal ones of A0 = 0.129 m-1 and D = 5.17 × 10-7 m2 s-1. Although the PTVI is only suitable for measuring the rotationally symmetric OPC, it shows less computation burden and hardware complexity, and it is proved to be a highly sensitive and effective tool in studying optical, thermo-physical, and mechanical properties of optical elements.

5.
Med Phys ; 50(8): 5262-5272, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37345373

RESUMO

BACKGROUND: Minibeam radiation therapy (MBRT) is an innovative dose delivery method with the potential to spare normal tissue while achieving similar tumor control as conventional radiotherapy. However, it is difficult to use a single dose parameter, such as mean dose, to compare different patterns of MBRT due to the spatially fractionated radiation. Also, the mechanism leading to the biological effects is still unknown. PURPOSE: This study aims to demonstrate that the hydrogen peroxide (H2 O2 ) distribution could serve as a surrogate of dose distribution when comparing different patterns of MBRT. METHODS: A free diffusion model (FDM) for H2 O2 developed with Fick's second law was compared with a previously published model based on Monte Carlo & convolution method. Since cells form separate compartments that can eliminate H2 O2 radicals diffusing inside the cell, a term describing the elimination was introduced into the equation. The FDM and the diffusion model considering removal (DMCR) were compared by simulating various dose rate irradiation schemes and uniform irradiation. Finally, the DMCR was compared with previous microbeam and minibeam animal experiments. RESULTS: Compared with a previous Monte Carlo & Convolution method, this analytical method provides more accurate results. Furthermore, the new model shows H2 O2 concentration distribution instead of the time to achieve a certain H2 O2 uniformity. The comparison between FDM and DMCR showed that H2 O2 distribution from FDM varied with dose rate irradiation, while DMCR had consistent results. For uniform irradiation, FDM resulted in a Gaussian distribution, while the H2 O2 distribution from DMCR was close to the dose distribution. The animal studies' evaluation showed a correlation between the H2 O2 concentration in the valley region and treatment outcomes. CONCLUSION: DMCR is a more realistic model for H2 O2 simulation than the FDM. In addition, the H2 O2 distribution can be a good surrogate of dose distribution when the minibeam effect could be observed.


Assuntos
Neoplasias , Radiometria , Animais , Radiometria/métodos , Simulação por Computador , Método de Monte Carlo , Modelos Teóricos , Dosagem Radioterapêutica
6.
Opt Lett ; 48(11): 2885-2888, 2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-37262235

RESUMO

An interferogram demodulation method based on azimuthal complex spectrum analysis is proposed for achieving picometer-scale accuracy with an optical vortex interferometer (OVI). The OVI uses conjugated p-radial-order Laguerre-Gaussian beams to produce a high-order petal-like interferogram. A camera with a multi-ring pattern written on its sensor is used to convert the interferogram into multiple azimuthal intensity profiles. A phase shift subjected to either uniform surface displacement or axisymmetric non-uniform surface deformation can be retrieved from the complex spectra of the azimuthal intensity profiles at the main frequency components. The experiment verified that the measurement error is 84 pm for a displacement of 10 nm and 0.359 nm for a deformation magnitude of 100 nm. The effect of surface misalignment on the measurement result is also discussed. The proposed method provides an effective and highly accurate method of interferogram demodulation for the OVI and extends the applicability of OVI from uniform surface displacement measurement to axisymmetric non-uniform surface deformation measurement.

7.
Rev Sci Instrum ; 93(8): 083703, 2022 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-36050082

RESUMO

Dark-field detection has long been used to identify micron/submicron-sized surface defects benefiting from the broadening effect of the actual defect size caused by light scattering. However, the back-side scattering of a transmissive optical slab is inevitably confused with the front-side scattering phenomenon, resulting in deterioration of the signal-to-noise ratio (SNR) of the scattering signal and false alarms for real defect detection. To this end, a confocal line-scan laser scattering probe equipped with optical sectioning ability is proposed to separate the back-side scattering from the front-side scattering. The optical sectioning ability is realized through a confocal light scattering collector, which overcomes the restriction imposed on the numerical aperture (NA) and the field of view (FOV), reaching an FOV length of 90 mm and NA of 0.69. The line-scan principle of the probe protects itself from crosstalk because it produces only a laser spot on the tested surface in an instant. Experimental results verified that the probe has a line-scan length of 90 mm with a uniformity better than 98%, an rms electronic noise of 3.4 mV, and an rms background noise of 6.4 mV with laser on. The probe can reject the false back-side scattering light for a 2 mm thick fused silica slab at 17.1 dB SNR and operate at a high imaging efficiency of 720 mm2/s with a minimum detectability limit of 1.4 µm at 12 dB SNR. This work put forward an effective method with great application value for submicron-sized defect detection in transmissive optics.

8.
Rev Sci Instrum ; 93(3): 033002, 2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-35364987

RESUMO

The production and consumption of austenitic stainless steel account for about 70% of stainless steel worldwide. The content of chromium (Cr) must be accurately detected and controlled to form a stable austenite structure and obtain strong properties in production. Laser-induced breakdown spectroscopy (LIBS) can be used to detect the Cr content of austenitic stainless steel in a complex production process. However, LIBS signals may be weak and unstable because the experimental signals are seriously affected by noise, self-absorption, the matrix effect, and the instability of the shot-to-shot signal, rendering the quantitative detection results inaccurate and unstable. The spectral-preprocessing methods of baseline correction and denoising can improve the accuracy of quantitative detection of LIBS. An improved segmented Hermite cubic-interpolation method is proposed herein to correct the baseline offset and produce baseline signals that are smooth and convergent (to overcome the Runge phenomenon). Empirical mode decomposition (EMD) based on the wavelet method is proposed to remove LIBS noise; this is done by exploiting the adaptivity of EMD to refine the wavelet-scaling coefficients. Compared with other denoising methods, the proposed method has good denoising evaluation indices and stability and, thus, effectively removes the noise. To verify detection accuracy, the internal standard quantitative method is used to detect the Cr content, and a cyclic-inversion prediction method is designed to verify detection stability. The results show that the correlation coefficient of the calibration curve is improved, the root-mean-square error is reduced, and the average relative error of the predicted Cr content decreases from 10.46% to 3.858%.

9.
Rev Sci Instrum ; 92(10): 103701, 2021 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-34717417

RESUMO

Automatic inspection of micro-defects of thin film transistor-liquid crystal display (TFT-LCD) panels is a critical task in LCD manufacturing. To meet the practical demand of online inspection of a one-dimensional (1D) line image captured by the line scan visual system, we propose a robust 1D Fourier reconstruction method with the capability of automatic determination of the period Δx of the periodic pattern of a spatial domain line image and the neighboring length r of the frequency peaks of the corresponding frequency domain line image. Moreover, to alleviate the difficulty in the discrimination between the defects and the non-uniform illumination background, we present an effective way to correct the non-uniform background using robust locally weighted smoothing combined with polynomial curve fitting. As a proof-of-concept, we built a line scan visual system and tested the captured line images. The results reveal that the proposed method is able to correct the non-uniform illumination background in a proper way that does not cause false alarms in defect inspection but also preserves complete information about the defects in terms of the brightness and darkness as well as the shape, indicating its distinct advantage in defect inspection of TFT-LCD panels.

10.
Opt Lett ; 46(12): 2976-2979, 2021 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-34129588

RESUMO

The sensitivity of photothermal detection relies on both the magnitude of the response of a sample to excitation and the way the response is sensed. We propose a highly sensitive photothermal interferometry by addressing the above two issues. One is the use of moving excitation to enable a different manner in sample heating and cooling, which results in a strong thermoelastic response of the sample. The other is the use of a balanced Mach-Zehnder interferometer with a defocused probe beam to sense the complex response induced by the phase delays taking place at the sample surface and in the surrounding air. The method was verified experimentally with a Nd-doped glass to have 68-fold sensitivity enhancement over the classical photothermal common-path interferometry.

11.
Opt Express ; 28(20): 29865-29875, 2020 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-33114876

RESUMO

Photothermal spectroscopy (PTS) working in the mid-infrared region is an effective technique for in-situ characterization of the chemical composition of surface contaminants. The sensitivity relies on the way that the laser-induced response of the sample is detected. We present a highly-sensitive PTS assisted with a dual-wavelength Mach-Zehnder interferometer (MZI), MZI-PST in short. The MZI aims to sense all the phase delays taking place at the sample and air when the heat produced by resonance absorption of the contaminant is transferred into its surroundings and further to amplify the total phase delay to a large intensity difference of a probe beam. To guarantee a stable quadrature phase bias of the MZI working in the balanced detection mode, we employ two separate wavelengths, one for sensing and the other for phase bias feedback, to lock the working point to the quadrature point in real time. The MZI is expected to have a 7.8-fold sensitivity enhancement compared with the conventional phase-sensitive PTS in theory. The results of the proof-of-concept experiment on the olive oil contaminated on a wafer surface verify the spectral fidelity and the sensitivity enhancement as well as the capability of photothermal spectral imaging of the MZI-PST.

12.
Opt Express ; 28(8): 11393-11405, 2020 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-32403651

RESUMO

The strong coupling effect of thermal and plasma waves disturbs the accurate characterization of thermal properties of semiconductors under super bandgap energy photon excitation. We propose a time-resolved laser scanning photothermal microscopy to decouple the thermo-electronic effect for accurate determination of the thermal diffusivity of a semi-insulating GaAs sample. The distinct advantage of the decoupling principle relies on that the scanning excitation of a laser beam on the sample surface introduces different transient and steady-state characteristics into the thermal and electronic parts of the photothermal response, where the transients between the thermal and electronic parts have a large time-scale separation, and the steady states show an enhanced thermal effect over the electronic effect. Therefore, the plasma wave is simply responsible for a negligible constant background in the thermo-electronic coupling. The theoretical and experimental results confirmed that the time-resolved photothermal signal is insensitive to the electronic transport parameters varying even by several orders of magnitude and can be used to determine the thermal diffusivity from its best fit. Moreover, the scanning excitation nature of this method allows for high-efficiency photothermal imaging of the sample to identify the thermal defects.

13.
Rev Sci Instrum ; 89(11): 114904, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30501284

RESUMO

Surface thermal lensing (STL) is a high sensitive pump-probe technique for photothermal characterization of weakly absorbing defects in optical materials. Commonly, the frequency modulation is applied in the pump beam, and the STL signal that appears as small modulation on top of an intense background is then detected on the probe beam by lock-in amplification. However, the lock-in detection by filtering the signal in the frequency domain results in low efficiency in the STL, preventing investigations of the large area surfaces. Here it is shown that the multi-channel averaging, which corresponds to temporal integration, is better suited for detection of the STL signal. It is demonstrated that by converting the conventional single-point scanning STL to the line scanning STL and employing suitable width of the time bins and the number of records, the imaging speed of the multi-channel averaging detection can be improved by a factor of 3.7 relative to the lock-in detection at the same signal-to-noise ratio of 6 dB and imaging resolution of 20 µm. Therefore, high-quality photothermal images of weakly absorbing defects can be recorded with higher efficiency and lower laser irradiance, making it possible to investigate large samples.

14.
J Radiat Res ; 57(5): 460-467, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27342838

RESUMO

Electron paramagnetic resonance (EPR) is a promising biodosimetric method, and fingernails are sensitive biomaterials to ionizing radiation. Therefore, kinetic energy released per unit mass (kerma) can be estimated by measuring the level of free radicals within fingernails, using EPR. However, to date this dosimetry has been deficient and insufficiently accurate. In the sampling processes and measurements, water plays a significant role. This paper discusses many effects of water on fingernail EPR dosimetry, including disturbance to EPR measurements and two different effects on the production of free radicals. Water that is unable to contact free radicals can promote the production of free radicals due to indirect ionizing effects. Therefore, varying water content within fingernails can lead to varying growth rates in the free radical concentration after irradiation-these two variables have a linear relationship, with a slope of 1.8143. Thus, EPR dosimetry needs to be adjusted according to the water content of the fingernails of an individual. When the free radicals are exposed to water, the eliminating effect will appear. Therefore, soaking fingernail pieces in water before irradiation, as many researchers have previously done, can cause estimation errors. In addition, nails need to be dehydrated before making accurately quantitative EPR measurements.


Assuntos
Espectroscopia de Ressonância de Spin Eletrônica/métodos , Dedos/efeitos da radiação , Unhas/efeitos da radiação , Radiometria/métodos , Água/química , Adulto , Dessecação , Feminino , Radicais Livres/análise , Humanos , Masculino , Pessoa de Meia-Idade , Processamento de Sinais Assistido por Computador , Adulto Jovem
15.
Radiat Prot Dosimetry ; 171(3): 297-303, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26290185

RESUMO

A fast and accurate retrospective dosimetry method for the triage is very important in radiation accidents. Electron paramagnetic resonance (EPR) fingernail dosimetry is a promising way to estimate radiation dose. This article presents two factors influencing dose reconstruction in low dose range: the variability of background signal (BKG) intensity on one individual and water content. Comparing the EPR spectrum of dried and humidified fingernail samples, it is necessary to add a procedure of dehydration before EPR measurements, so as to eliminate the deviation caused by water content. Besides, the BKGs of different fingers' nails are not the same as researchers thought previously, and the difference between maximum and minimum BKG intensities of one individual can reach 55.89 %. Meanwhile, the variability of the BKG intensity among individuals is large enough to impact precise dose reconstruction. Water within fingernails and instability of BKG are two reasons that cause the inaccuracy of radiation dose reconstruction in low-dosage level.


Assuntos
Unhas/diagnóstico por imagem , Doses de Radiação , Radiometria/métodos , Água/química , Adulto , Dessecação , Espectroscopia de Ressonância de Spin Eletrônica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Processamento de Sinais Assistido por Computador
16.
Neural Regen Res ; 9(12): 1204-9, 2014 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-25206783

RESUMO

The use of iodine-125 ((125)I) in cancer treatment has been shown to relieve patients' pain. Considering dorsal root ganglia are critical for neural transmission between the peripheral and central nervous systems, we assumed that (125)I could be implanted into rat dorsal root ganglia to provide relief for neuropathic pain. (125)I seeds with different radioactivity (0, 14.8, 29.6 MBq) were implanted separately through L4-5 and L5-6 intervertebral foramen into the vicinity of the L5 dorsal root ganglion. von Frey hair results demonstrated the mechanical pain threshold was elevated after implanting (125)I seeds from the high radioactivity group. Transmission electron microscopy revealed that nuclear membrane shrinkage, nucleolar margination, widespread mitochondrial swelling, partial vacuolization, lysosome increase, and partial endoplasmic reticulum dilation were visible at 1,440 hours in the low radioactivity group and at 336 hours in the high radioactivity group. Abundant nuclear membrane shrinkage, partial fuzzy nuclear membrane and endoplasmic reticulum necrosis were observed at 1,440 hours in the high radioactivity group. No significant difference in combined behavioral scores was detected between preoperation and postoperation in the low and high radioactivity groups. These results suggested that the mechanical pain threshold was elevated after implanting (125)I seeds without influencing motor functions of the hind limb, although cell injury was present.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA