Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 278
Filtrar
1.
Lab Med ; 2024 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-39110891

RESUMO

INTRODUCTION: Laboratories use their performance in external quality assurance (EQA) to establish quality planning strategies and to assess whether testing processes require improvement. METHODS: The EQA performance of the hematology and coagulation test parameters on the Royal College of Pathologists of Australasia EQA program was evaluated over a 4-year cycle at an academic hospital in Johannesburg, South Africa. The test performance was determined from analytical quality specification (APS) and/or z-scores. Bias and imprecision were used to calculate sigma (σ) metric scores. Specifications from European Federation of Laboratory Medicine and/or biological variation were applied. RESULTS: The laboratory achieved a mean testing score of 98.7 ± 4.0%. There were 103 (10.7%) unacceptable results. On investigation, root causes included: presurvey issues (83%), transcription errors (9%), random errors (6%), and test performance errors (3%). All test parameters evaluated achieved an acceptable median APS during the study period. The mean z-scores, however, were >2 and unacceptable for mean cell hemoglobin concentration and hematocrit. On investigation, this was attributed to significant delay in transport and storage of full blood count samples. White cell count and d-dimer achieved a σ ≥ 6. CONCLUSION: EQA participation assisted the laboratory in maintaining a quality system. Close monitoring is necessary for international laboratories to avoid sample delays that can affect result quality.

2.
Food Chem ; 460(Pt 2): 140548, 2024 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-39096799

RESUMO

Electrochemical sensors and electroanalytical techniques become emerging as effective and low-cost tools for rapid assessment of special parameters of the food quality. Chemically modified electrodes are developed to change properties and behaviour, particularly sensitivity and selectivity, of conventional electroanalytical sensors. Within this comprehensive review, novel trends in chemical modifiers material structure, electrodes construction and flow analysis platforms are described and evaluated. Numerous recent application examples for the detection of food specific analytes are presented in a form of table to stimulate further development in both, the basic research and commercial field.

3.
ACS Sens ; 2024 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-39074375

RESUMO

The detection of small molecules beyond glucose remains an ongoing challenge in the field of biomolecular sensing owing to their small size, diverse structures, and lack of alternative non-enzymatic sensing methods. Here, we present a new reagentless electrochemical approach for small molecule detection that involves directed movement of electroactive analytes through a self-assembled monolayer to an electrode surface. Using this method, we demonstrate detection of several physiologically relevant small molecules as well as the capacity for the system to operate in several biological fluids. We anticipate that this mechanism will further improve our capacity for small molecule measurement and provide a new generalizable monolayer-based technique for electrochemical assessment of various electroactive analytes.

4.
Indian J Clin Biochem ; 39(3): 1-12, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39005866

RESUMO

Despite immense importance of reference intervals (RIs) for clinical diagnosis, there have been no reliable RIs available for Nepalese. Hence, this nationwide study was organized to establish RIs for 30 common biochemical parameters. This study was conducted following the harmonized protocol provided by IFCC Committee on Reference Interval and Decision Limits (C-RIDL) with recruitment of 617 apparently healthy volunteers (18 - 65 years) by near-equal gender balance from 5 major cities. Fasting blood were collected, serum was separated and measured collectively using Beckman-Coulter/Olympus AU480 chemistry analyzer. The sources of variations of reference values (RVs) were evaluated by multiple regression analysis and nested ANOVA. Latent abnormal values exclusion (LAVE) method was applied to reduce influence of latent diseases. RIs were standardized based on a value-assigned serum panel provided by C-RIDL. By ANOVA, no between-city differences were observed, while sex-related changes were typically noted for urate, creatinine, iron, γ-glutamyl transferase (GGT), immunoglobulin M, and transferrin, but not for high-density lipoprotein cholesterol. Age-related changes were observed for total cholesterol (TC), triglyceride, low-density lipoprotein cholesterol, and C-reactive protein (CRP). RIs were successfully derived all parametrically. The LAVE procedure was effective in lowering upper limits for aspartate aminotransferase, alanine aminotransferase (ALT), and CRP. Compared to other collaborating countries, Nepalese RIs were low for urea, cholesterols, ALT, and high for triglyceride, GGT, CRP, immunoglobulin G, and complements. The RIs for major chemistry analytes were derived and standardized for nationwide use in Nepal. This study distinctly elucidated sources of variation and international features of Nepalese RIs. Supplementary Information: The online version supplementary material available at 10.1007/s12291-023-01123-6.

5.
Biosensors (Basel) ; 14(7)2024 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-39056592

RESUMO

Self-powered biosensors are innovative devices that can detect and analyze biological or chemical substances without the need for an external power source. These biosensors can convert energy from the surrounding environment or the analyte itself into electrical signals for sensing and data transmission. The self-powered nature of these biosensors offers several advantages, such as portability, autonomy, and reduced waste generation from disposable batteries. They find applications in various fields, including healthcare, environmental monitoring, food safety, and wearable devices. While self-powered biosensors are a promising technology, there are still challenges to address, such as improving energy efficiency, sensitivity, and stability to make them more practical and widely adopted. This review article focuses on exploring the evolving trends in self-powered biosensor design, outlining potential advantages and limitations. With a focal point on enzymatic biofuel cell power generation, this article describes various sensing mechanisms that employ the analyte as substrate or fuel for the biocatalyst's ability to generate current. Technical aspects of biofuel cells are also examined. Research and development in the field of self-powered biosensors is ongoing, and this review describes promising areas for further exploration within the field, identifying underexplored areas that could benefit from further investigation.


Assuntos
Fontes de Energia Bioelétrica , Técnicas Biossensoriais , Enzimas/metabolismo
6.
Talanta ; 279: 126515, 2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-39024854

RESUMO

The widespread adoption of small-molecule fluorescence detection methodologies in scientific research and industrial contexts can be ascribed to their inherent merits, including elevated sensitivity, exceptional selectivity, real-time detection capabilities, and non-destructive characteristics. In recent years, there has been a growing focus on small-molecule fluorescent probes engineered with sulfur elements, aiming to detect a diverse array of biologically active species. This review presents a comprehensive survey of sulfur-based fluorescent probes published from 2017 to 2023. The diverse repertoire of recognition sites, including but not limited to N, N-dimethylthiocarbamyl, disulfides, thioether, sulfonyls and sulfoxides, thiourea, thioester, thioacetal and thioketal, sulfhydryl, phenothiazine, thioamide, and others, inherent in these sulfur-based probes markedly amplifies their capacity for detecting a broad spectrum of analytes, such as metal ions, reactive oxygen species, reactive sulfur species, reactive nitrogen species, proteins, and beyond. Owing to the individual disparities in the molecular structures of the probes, analogous recognition units may be employed to discern diverse substrates. Subsequent to this classification, the review provides a concise summary and introduction to the design and biological applications of these probe molecules. Lastly, drawing upon a synthesis of published works, the review engages in a discussion regarding the merits and drawbacks of these fluorescent probes, offering guidance for future endeavors.

7.
J Fluoresc ; 2024 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-39018001

RESUMO

Fluorescent chemosensors have become vital tools for detecting toxic ions due to their exceptional sensitivity, selectivity, and rapid response times. These sensors function through various mechanisms, each providing unique advantages for specific applications. This review offers a comprehensive overview of the mechanistic innovations in fluorescent chemosensors, emphasizing five key approaches: Photoinduced Electron Transfer (PET), Fluorescence Resonance Energy Transfer (FRET), Intramolecular Charge Transfer (ICT), Aggregation-Induced Emission (AIE), and Excited-State Intramolecular Proton Transfer (ESIPT). We highlight the substantial progress made in developing these chemosensors, discussing their design principles, sensing mechanisms, and practical applications, with a particular focus on their use in detecting toxic ions relevant to environmental and biological contexts.

8.
Anal Biochem ; 693: 115582, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38825160

RESUMO

Progress has been made studying cell-cell signaling communication processes. However, due to limitations of current sensors on time and spatial resolution, the role of many extracellular analytes is still unknown. A single walled carbon nanotube (SWNT) platform was previously developed based on the avidin-biotin immobilization of SWNT to a glass substrate. The SWNT platform provides real time feedback about analyte concentration and has a high concentration of evenly distributed sensors, both of which are essential for the study of extracellular analytes. Unfortunately, this initial SWNT platform is synthesized through unsterile conditions and cannot be sterilized post-production due to the delicate nature of the sensors, making it unsuitable for in vitro work. Herein the multiple-step process for SWNT immobilization is modified and the platform's biocompatibility is assessed in terms of sterility, cytotoxicity, cell proliferation, and cell morphology through comparison with non-sensors controls. The results demonstrate the SWNT platform's sterility and lack of toxicity over 72 h. The proliferation rate and morphology profiles for cells growing on the SWNT platform are similar to those grown on tissue culture substrates. This novel nano-sensor platform preserves cell health and cell functionality over time, offering opportunities to study extracellular analytes gradients in cellular communication.


Assuntos
Nanotubos de Carbono , Nanotubos de Carbono/química , Humanos , Proliferação de Células , Biotina/química , Técnicas Biossensoriais/métodos , Avidina/química
9.
J Chromatogr A ; 1730: 465059, 2024 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-38905948

RESUMO

To date, the most commonly used column characterization databases do not determine the relative positive charge associated with new generation RP columns, or they fail to successfully discriminate between RP columns of purportedly low level positive and neutral characters. This paper rectifies this in that it describes a convenient and robust chromatographic procedure for the assessment of the low levels of positive charge on a range of RP columns. The low degree of positive charge was determined by their electrostatic attraction towards the negatively charged 4-n-octylbenzene sulfonic acid (4-OBSA) relative to their retention of the hydrophobic marker toluene (Tol). The new parameter (α4-OBSA/Tol) was determined for 15 commercially available RP-LC columns. When this was combined with existing Tanaka parameters it was possible to guide the chromatographer towards similar columns as "backup / equivalent phases" or dissimilar columns for exploitation in method development strategies. It should be noted that under certain chromatographic conditions the retention mechanism(s) may be too complex to allow direct location of a "backup / equivalent" column(s). The α4-OBSA/Tol results indicate that even the new generation neutral alkyl phases may exhibit a small degree of positive charge at low buffer concentrations. Mobile phases containing low % MeCN were demonstrated to promote mixed mode (anionic exchange / hydrophobic) retention whereas at high % MeCN anionic exchange retention dominated. The measure of electrostatic repulsion between positively charged columns and positively charged bases was assessed by evaluating the relative retention of a range of bases and neutral analytes. The greatest electrostatic repulsion was observed with hydrophilic bases. While there was no correlation between the positive charge associated with the phases assessed by electrostatic attraction or repulsion, the columns could be broadly divided into three subsets (i.e., significant positive character, medium to low positive character and insignificant positive character). Finally, the results were used to highlight the usefulness of the column characterization database containing the new anionic exchange retention parameter (α4-OBSA/Tol) for the selection of an equivalent column possessing a low level of positive character in the analysis of a real-life biopharmaceutical application.


Assuntos
Cromatografia de Fase Reversa , Interações Hidrofóbicas e Hidrofílicas , Eletricidade Estática , Tolueno , Cromatografia de Fase Reversa/métodos , Tolueno/química , Cromatografia Líquida de Alta Pressão/métodos
10.
Biomolecules ; 14(6)2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38927049

RESUMO

We recently reported the potential application of recombinant prothrombin activator ecarin (RAPClot™) in blood diagnostics. In a new study, we describe RAPClot™ as an additive to develop a novel blood collection prototype tube that produces the highest quality serum for accurate biochemical analyte determination. The drying process of the RAPClot™ tube generated minimal effect on the enzymatic activity of the prothrombin activator. According to the bioassays of thrombin activity and plasma clotting, γ-radiation (>25 kGy) resulted in a 30-40% loss of the enzymatic activity of the RAPClot™ tubes. However, a visual blood clotting assay revealed that the γ-radiation-sterilized RAPClot™ tubes showed a high capacity for clotting high-dose heparinized blood (8 U/mL) within 5 min. This was confirmed using Thrombelastography (TEG), indicating full clotting efficiency under anticoagulant conditions. The storage of the RAPClot™ tubes at room temperature (RT) for greater than 12 months resulted in the retention of efficient and effective clotting activity for heparinized blood in 342 s. Furthermore, the enzymatic activity of the RAPClot™ tubes sterilized with an electron-beam (EB) was significantly greater than that with γ-radiation. The EB-sterilized RAPClot™ tubes stored at RT for 251 days retained over 70% enzyme activity and clotted the heparinized blood in 340 s after 682 days. Preliminary clinical studies revealed in the two trials that 5 common analytes (K, Glu, lactate dehydrogenase (LD), Fe, and Phos) or 33 analytes determined in the second study in the γ-sterilized RAPClot™ tubes were similar to those in commercial tubes. In conclusion, the findings indicate that the novel RAPClot™ blood collection prototype tube has a significant advantage over current serum or lithium heparin plasma tubes for routine use in measuring biochemical analytes, confirming a promising application of RAPClot™ in clinical medicine.


Assuntos
Proteínas Recombinantes , Humanos , Coagulação Sanguínea/efeitos dos fármacos , Soro/química , Soro/metabolismo , Tromboplastina/metabolismo , Coleta de Amostras Sanguíneas/métodos , Tromboelastografia/métodos , Raios gama , Anticoagulantes/farmacologia , Anticoagulantes/química
11.
Molecules ; 29(9)2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38731614

RESUMO

In this study, water was used as an additive in the methanol-modified carbon dioxide-based eluent for the elution of some basic organic compounds from a hybrid silica column via supercritical fluid chromatography (SFC). The experiments were applied to sulfonamides, propranolol, and other organic nitrogen compounds involving aromatic rings from different classes of amine, pyrimidine, and purine with different pKa values (the pKa values for the studied analytes range from 4.6 to 10.4). The results revealed different responses to the different percentages of water addition. Adding 1~2% of water to the modifier (methanol) led to a positive effect manifested by more symmetrical peak shapes and reduced retention times for most compounds. The key factor for this improvement in the properties of chromatographic peaks is due to the adsorption of water on the silanol groups of the stationary phase, consequently resembling the phenomena observed in hydrophilic interaction liquid chromatography (HILIC). Moreover, the availability of hydrogen bond acceptor and donor sites in the analyte structure is an important factor to be considered when adding water as an additive to the modifier for improving the chromatographic peaks. However, introducing water in an amount higher than 3% resulted in perturbed chromatographic signals. It was also found that water as an additive alone could not successfully elute propranolol from the hybrid silica column with an acceptable peak shape; thus, the addition of a strong base such as amine salts was also necessary. The proposed use of a particular amount of water in the mobile phase could have a positive effect compared to the same mobile phase without water, improving the chromatographic peak properties of the elution of some basic organic compounds from the hybrid silica column.

12.
Pathogens ; 13(5)2024 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-38787210

RESUMO

This study demonstrates the capability of Raman microscopy for detecting structural differences in Giardia cells exposed to different drugs and incubation times. While metronidazole (MTZ) visibly affects the cells by inducing extracellular vesicle releases of toxic iron intermediates and modified triple-bond moieties, oseltamivir (OSM) alters the phenylalanine and lipid structures. Modifications in the heme protein environment and the transformation of iron from ferric to ferrous observed for both drug treatments are more notable for MTZ. Different contents and amounts of vesicle excretion are detected for 24 h or 48 h with MTZ incubation. At a shorter drug exposure, releases of altered proteins, glycogen, and phospholipids dominate. Agglomerates of transformed iron complexes from heme proteins and multiple-bond moieties prevail at 48 h of treatment. No such vesicle releases are present in the case of OSM usage. Drug incorporations into the cells and their impact on the plasma membrane and the dynamics of lipid raft confirmed by confocal fluorescence microscopy reveal a more destructive extent by OSM, corroborating the Raman results. Raman microscopy provides a broader understanding of the multifaceted factors and mechanisms responsible for giardiasis treatment or drug resistance by enabling a label-free, simultaneous monitoring of structural changes at the cellular and molecular levels.

13.
Biomed Chromatogr ; 38(7): e5876, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38600635

RESUMO

The two-step preconcentration technique consisting of large-volume sample stacking (LVSS) and micelle to solvent stacking (MSS) in cyclodextrin-modified electrokinetic chromatography (CDEKC) was developed for the analysis of five cationic alkaloids in complex Chinese herbal prescriptions. Relevant parameters affecting separation and stacking performance were optimized separately. Under the optimal LVSS-MSS-CDEKC conditions, less analysis time and organic solvent were required, and the enhancement factors of analytes ranged from 12 to 15 compared with the normal CDEKC separation mode. Further, all validation results demonstrated good applicability and multiple alkaloids (epiberberine, dehydrocorydaline, jatrorrhizine, coptisine and berberine) in Yangxinshi tablet (YXST) have been simultaneously determined. This approach presents powerful potential for the determination of multiple components in complex preparations of Chinese medicine.


Assuntos
Alcaloides , Cromatografia Capilar Eletrocinética Micelar , Medicamentos de Ervas Chinesas , Comprimidos , Medicamentos de Ervas Chinesas/química , Medicamentos de Ervas Chinesas/análise , Cromatografia Capilar Eletrocinética Micelar/métodos , Comprimidos/química , Alcaloides/análise , Alcaloides/química , Reprodutibilidade dos Testes , Micelas , Modelos Lineares , Ciclodextrinas/química , Limite de Detecção
14.
J Fluoresc ; 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38607529

RESUMO

Porphyrins and porphyrin derivatives have been intensively explored for a number of applications such as sensing, catalysis, adsorption, and photocatalysis due to their outstanding photophysical properties. Their usage in sensing applications, however, is limited by intrinsic defects such as physiological instability and self-quenching. To reduce self-quenching susceptibility, researchers have developed porphyrin metal-organic frameworks (MOFs). Metal-organic frameworks (MOFs), a unique type of hybrid porous coordination polymers comprised of metal ions linked by organic linkers, are gaining popularity. Porphyrin molecules can be integrated into MOFs or employed as organic linkers in the production of MOFs. Porphyrin-based MOFs are a separate branch of the huge MOF family that combines the distinguishing qualities of porphyrins (e.g., fluorescent nature) and MOFs (e.g., high surface area, high porosity) to enable sensing applications with higher sensitivity, specificity, and extended target range. The key synthesis techniques for porphyrin-based MOFs, such as porphyrin@MOFs, porphyrinic MOFs, and composite porphyrinic MOFs, are outlined in this review article. This review article focuses on current advances and breakthroughs in the field of porphyrin-based MOFs for detecting a variety of targets (for example, metal ions, anions, explosives, biomolecules, pH, and toxins). Finally, the issues and potential future uses of this class of emerging materials for sensing applications are reviewed.

15.
Animals (Basel) ; 14(3)2024 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-38338017

RESUMO

Saliva is an important exocrine fluid that is easy to collect and is a complex mixture of proteins and other molecules from multiple sources from which considerable biological information can be mined. Pig saliva, as an easily available biological liquid rich in bioactive ingredients, is rich in nucleic acid analytes, such as eggs, enzymes, amino acids, sugars, etc. The expression levels of these components in different diseases have received extensive attention, and the analysis of specific proteins, metabolites, and biological compositions in pig saliva has become a new direction for disease diagnosis and treatment. The study of the changes in analytes in pig saliva can provide a new strategy for early diagnosis, prognosis assessment, and treatment of diseases. In this paper, the detection methods and research progress of porcine salivary analytes are reviewed, the application and research progress of porcine salivary analytes in diseases are discussed, and the future application prospect is presented.

16.
J Sep Sci ; 47(3): e2300801, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38356234

RESUMO

Generic electromembrane extraction (EME) methods were developed and optimized for basic analytes of moderate or low polarity, employing prototype conductive vial EME equipment. Two generic methods, B1 and B2, were devised for mono- and dibasic compounds with distinct polarity windows: 2.0 < log P < 6.0 for B1 and 1.0 < log P < 4.5 for B2. In B1, 10 µL of 2-nitrophenyl octyl ether served as the liquid membrane, while B2 utilized 10 µL of 2-undecanone. Both methods involved the acidification of 125 µL of human plasma samples with 125 µL of sample diluent (0.5 M HCOOH for B1 and 1.0 M HCOOH for B2). The acceptor phase consisted of 250 µL of 100 mM HCOOH. Extraction was conducted for 30 min with agitation at 800 rpm, employing an extraction potential of 100 V for B1 and 50 V for B2. A set of 90 pharmaceutical compounds was employed as model analytes. Both B1 and B2 demonstrated high recoveries (40%-100%) for the majority of model analytes within their respective polarity windows. Intra-day precision was within 2.2% and 9.7% relative standard deviation. Both extraction systems exhibited stability in terms of current, matrix effect values were between 90% and 109%.

17.
Animal ; 18(3): 101095, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38367311

RESUMO

Milk markers have the potential to aid in the detection of cow disease in early lactation if the automation of milk analysis becomes commonplace. Characterising temporal profiles of milk markers in dairy cows will improve the understanding of basal concentrations in clinically healthy cows. The objective of this observational study was to characterise the variation and temporal profiles of colostrum and milk haptoglobin (Hp) and substance P concentrations within 21 days postcalving in clinically healthy multiparous Holstein dairy cows. Ninety Holstein dairy cows from a commercial dairy herd were included. Milk samples were collected on the day of calving (day 0), and on days 1 to 4, 7, 14, and 21 postcalving and concentrations of Hp and substance P in colostrum (days 0 to 3) and milk (days 4, 7, 14, and 21) were determined using Enzyme Linked Immunosorbent assay. Haptoglobin and substance P concentrations were, on average (raw means ± SD), 0.40 ± 0.26 µg/ml and 56.2 ± 38.7 pg/ml in colostrum, respectively, and 0.23 ± 0.23 µg/ml and 37.1 ± 27.8 pg/ml in milk, respectively. Haptoglobin and substance P were elevated and greatest 1 day postcalving (least squares mean ± SE of the mean; 0.53 ± 0.05 µg/ml and 46.5 ± 3.64 pg/ml, respectively) and substance P varied widely within 21 days postcalving. The presence of substance P in dairy cow colostrum was not documented previously. Elevated concentrations of Hp and substance P immediately postcalving may be due to physiological roles these inflammatory markers have in the dairy cow or neonate or may simply represent an accumulation in colostrum before the first milk is removed.


Assuntos
Colostro , Leite , Gravidez , Feminino , Bovinos , Animais , Haptoglobinas , Substância P , Lactação/fisiologia
18.
Biosens Bioelectron ; 250: 116059, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38280297

RESUMO

Nowadays, the diagnose of depression mainly relies on clinical examination while impossible to accurately evaluate the occurrence of depression. Chemical approaches are captivating to analyze stress biomarkers for feedbacking body's endocrine response to stress stimuli. However, it remains challenging in exploring accurate, reliable and sensitive approaches. Herein, we rationally design a newly SERS platform with integrated hotspots engineering and analyte strategy to achieve highly sensitive analysis for estrogen, a typical depression biomarker in adolescent female. On the one hand, the 3D micro/nano plasmonic substrate containing Au-Ag Alloy Nanourchins (AAA-NUs) and arrays-based monolayer films of Au nanoparticles (Au NSs) was constructed to achieve high density and availability of hotspots. On the other hand, the analyte strategy was designed via rapid azotizing reaction to further enhance the scattering cross-section of estrogen in the form of azido compounds. With the synergism of them, the proposed SERS platform displayed high sensitivity for estrogen with a limit of detection down to 10-11 mg/mL. More importantly, the blood estrogen levels of depressed patients were evaluated via the proposed SERS platform and presented high consistence with clinical diagnostic results. This integrated SERS platform paves the way for universal and ultrasensitive biosensing and possess great potential for applying in multi-target detection and disease prediction.


Assuntos
Técnicas Biossensoriais , Nanopartículas Metálicas , Humanos , Feminino , Adolescente , Ouro/química , Nanopartículas Metálicas/química , Depressão , Técnicas Biossensoriais/métodos , Biomarcadores , Estrogênios , Análise Espectral Raman/métodos
19.
Ann Clin Biochem ; 61(1): 19-31, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36650746

RESUMO

Diabetes insipidus (DI) is a group of disorders that lead to inappropriate production of large volumes of dilute urine. The three main forms are central DI (CDI), nephrogenic DI (NDI) and primary polydipsia (PP). Differentiating CDI/NDI from PP is important as patients with true DI are at risk of severe dehydration without treatment. Biochemical testing is key in the diagnosis of DI. The indirect water deprivation test (WDT) is commonly used in the investigation of DI but has drawbacks including being cumbersome and sometimes producing equivocal results. Direct measurement of AVP has theoretical advantages but has generally only been used in specialist centres. Disadvantages include the requirement to measure AVP under hypertonic stimulation and pre-analytical/analytical challenges. Copeptin (CT-proAVP) is a proxy marker for AVP that is more stable, easier to measure and has been studied more widely in recent years. Historically, the evidence supporting the diagnostic performance of these tests has been relatively poor, being based on a few small, usually single-centre studies. However more recent, well-designed prospective studies are improving the evidence base for investigation of DI. These studies have focused on the utility of copeptin measurements during stimulation tests. There is evidence that measurement of copeptin under stimulation offers improved diagnostic performance compared to the WDT. There is currently a lack of systematic, evidence-based guidelines on the diagnosis of DI, but as the quality of the evidence defining the diagnostic performance of tests for DI continues to improve, a clearer consensus on the optimal approach should become achievable.


Assuntos
Diabetes Insípido Neurogênico , Diabetes Insípido , Diabetes Mellitus , Humanos , Estudos Prospectivos , Poliúria/diagnóstico , Glicopeptídeos , Diagnóstico Diferencial , Diabetes Insípido/diagnóstico , Diabetes Insípido Neurogênico/diagnóstico , Diabetes Mellitus/diagnóstico
20.
Adv Sci (Weinh) ; 11(7): e2306125, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38044318

RESUMO

Multi-layered plasmonic nanostructures are able to highly promote the near-field confinement and effectively activate analytes, which are of predominate significance but are extremely challenging. Herein, the semi-open Au core@carved AuAg multi-shell superstructure nanoparticles (multi-Au@Ag-Au NPs, multi = mono, bi, tri, tetra, and penta) are reported with a high designability on electromagnetic field and capability of effectively capturing analytes. By controlling synthetic parameters such as the number of galvanic exchange and Ag growth, multi-Au@Ag-Au NPs are successfully obtained, with tunable layer numbers and asymmetric nanoholes. Due to collective plasmon oscillations of multi-layered built-in nanogaps, the electromagnetic field strength of a single penta-Au@Ag-Au entity reach 48841. More importantly, the penta-Au@Ag-Au NPs show a remarkable light-harvesting capability, which is adaptive to different Raman lasers, supporting high-diversity detection. Additionally, the structural specificity allows analytes to be sufficiently captured into interior hotspots, and further achieve highly sensitive detection with limit of detection down to 3.22 × 10-12  M. This study not only provides an effective pathway for integrating abundant hotspots and activating target molecules in single plasmonic superstructure, but stimulates advancements in SERS substrates for various applications.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA