Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Nanomaterials (Basel) ; 14(15)2024 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-39120365

RESUMO

The carbon nanotube cold cathode has important applications in the X-ray source, microwave tube, neutralizer, etc. In this study, the characteristics of carbon nanotube (CNT) electron gun in series with metal-oxide-semiconductor field-effect transistor (MOSFET) were studied. CNTs were prepared on a stainless steel substrate by chemical vapor deposition and assembled with a mesh gate to form an electron gun. The anode current of the electron gun can be accurately regulated by precisely controlling the MOSFET gate voltage in the subthreshold region from 1 to 40 µA. The current stability measurements show the cathode current fluctuation was 0.87% under 10 h continuous operation, and the corresponding anode current fluctuation was 2.3%. The result has demonstrated that the MOSFET can be applied for the precise control of the CNT electron gun and greatly improve current stability.

2.
Microsc Microanal ; 29(5): 1610-1617, 2023 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-37490647

RESUMO

Low-voltage scanning electron microscopy is a powerful tool for examining surface features and imaging beam-sensitive materials. Improving resolution during low-voltage imaging is then an important area of development. Decreasing the effect of chromatic aberration is one solution to improving the resolution and can be achieved by reducing the energy spread of the electron source. Our approach involves retrofitting a light source onto a thermionic lanthanum hexaboride (LaB6) electron gun as a cost-effective low energy-spread photoelectron emitter. The energy spread of the emitter's photoelectrons is theorized to be between 0.11 and 0.38 eV, depending on the photon energy of the ultraviolet (UV) light source. Proof-of-principle images have been recorded using this retrofitted photoelectron gun, and an analysis of its performance is presented.

3.
Microsc Microanal ; : 1-9, 2022 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-36062359

RESUMO

The energy distribution of an electron gun is one of the most important characteristics determining the performance of electron beam-based instruments, such as electron microscopes and electron energy loss spectroscopes. For accurate measurements of the energy distribution, this study presents a novel retarding field energy analyzer (RFEA) with the feature of an additional integrated pre-lens, which enables an adjustment of beam trajectory into the analyzer. The advantages of this analyzer are its compact size and simple electrode configuration. According to trajectory simulation theories, the optimum condition arises when the incident electron beam inside the RFEA is focused on the center of a retarding electrode. Comparing I­V curves depending on whether the pre-lens working or not, it is confirmed that the use of the pre-lens dramatically improves the energy resolution and efficiency of the signal acquisition process. The pre-lens RFEA was applied to characterize a Schottky electron gun under various temperatures and extraction voltages as operational conditions. When the tip temperature was increased by 50 K, we were able to measure an energy distribution broadening of 13.8 meV with the proposed pre-lens RFEA. The relative standard deviation of energy distribution was 0.7% for each working condition.

4.
Nanotechnology ; 33(41)2022 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-35785757

RESUMO

Improving the thruster efficiency is a crucial challenge for the development of space electric propulsion systems, especially advanced air-breathing thrusters utilizing the surrounding rarefied atmosphere as fuel. A significant reduction in thruster power consumption can be achieved by using field emission (FE) cathodes that do not require heating and have the highest energy efficiency. In this work, we study FE from nano-graphite thin films, consisting of carbon nanostructures with a high aspect ratio, and demonstrate their suitability for use in the space electric propulsion systems. The films shown appropriate FE characteristics in a wide range of gas pressures at high current loads in constant and pulsed operation modes. Based on the obtained experimental results, nano-graphite cathodes were employed for the design of an electron gun with increased reliability and minimized energy losses associated with electron extraction. The possibility of using such a gun in a specific air-breathing satellite operating in low Earth orbits is demonstrated.

5.
Micromachines (Basel) ; 12(11)2021 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-34832788

RESUMO

With the growing demand from scientific projects such as the X-ray free electron laser (XFEL), ultrafast electron diffraction/microscopy (UED/UEM) and electron ion collider (EIC), the semiconductor photocathode, which is a key technique for a high brightness electron source, has been widely studied in China. Several fabrication systems have been designed and constructed in different institutes and the vacuum of most systems is in the low 10-8 Pa level to grow a high QE and long lifetime photocathode. The QE, dark lifetime/bunch lifetime, spectral response and QE map of photocathodes with different kinds of materials, such as bialkali (K2CsSb, K2NaSb, etc.), Cs2Te and GaAs, have been investigated. These photocathodes will be used to deliver electron beams in a high voltage DC gun, a normal conducting RF gun, and an SRF gun. The emission physics of the semiconductor photocathode and intrinsic emittance reduction are also studied.

6.
Ultramicroscopy ; 230: 113386, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34534748

RESUMO

Temporal changes in carrier relaxations, magnetic switching, and biological structures are known to be in the order of ns. These phenomena can be typically measured by means of an optical-pump & electron-probe method using an electron microscope combined with a pulsed electron source. A photoemission-type pulsed electron gun makes it possible to obtain a short-pulsed electron beam required for high temporal resolution. On the other hand, spatial resolution is restricted by the brightness of the pulsed electron gun used in electron microscopes when a low brightness electron source is used and an irradiation current larger than a certain value is required. Thus, we constructed a prototype pulsed electron gun using a negative electron affinity (NEA) photocathode for time-resolved measurement using a scanning electron microscope (SEM) with high spatiotemporal resolution. In this study, a high-speed detector containing an avalanche photodiode (APD) was used to directly measure waveforms of the pulsed electron beam excited by a rectangular-shape pulsed light with a variable pulse duration in the range of several ns to several µs. The measured waveforms were the same rectangular shape as incident pulsed excitation light. The maximum peak brightness of the pulsed electron beam was 4.2×107 A/m2/sr/V with a pulse duration of 3 ns. This value was larger than that of the continuous electron beam (1.6 × 107 A/m2/sr/V). Furthermore, an SEM image with image sharpness of 6.2 nm was obtained using an SEM equipped with a prototype pulsed electron gun at an acceleration voltage of 3 kV.

7.
Zhongguo Yi Liao Qi Xie Za Zhi ; 45(1): 114-118, 2021 Feb 08.
Artigo em Chinês | MEDLINE | ID: mdl-33522190

RESUMO

The transportation of electron is inseparable from vacuum environment. The maintenance of the vacuum system of Elekta linear accelerator depends on two sputtering ionic pumps at the gun end and the target end. The traveling wave acceleration were used in Elekta linear accelerators. And the design of the electron gun filament is detachable. Because of these two reasons, the vacuum stability is relatively weak. Only two vacuum values are used to reflect the operation state of the whole vacuum system, which causes a few failures but will not trigger a the machine interlock. Considering the complexity of whole vacuum system, the problem of vacuum caused by the failure of various components in vacuum system is analyzed in this paper. It is hoped that some useful repairing experience and suggestions for the maintenance engineers of linear accelerator to solve the vacuum fault and rebuild the vacuum can be provided quickly.


Assuntos
Aceleradores de Partículas , Elétrons , Dosagem Radioterapêutica , Vácuo
8.
Comput Struct Biotechnol J ; 18: 1458-1465, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32637043

RESUMO

Aggregation is a critical parameter for protein-based therapeutics, due to its impact on the immunogenicity of the product. The traditional approach towards characterization of such products is to use a collection of orthogonal tools. However, the fact that none of these tools is able to completely classify the distribution and physical characteristics of aggregates, implies that there exists a need for additional analytical methods. We report one such method for characterization of heterogeneous population of proteins using transmission electron microscopy. The method involves semi-automated, size-based clustering of different protein species from micrographs. This method can be utilized for quantitative characterization of heterogeneous populations of antibody/protein aggregates from TEM images of proteins, and may also be applicable towards other instances of protein aggregation.

9.
Astrobiology ; 19(9): 1123-1138, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31084501

RESUMO

Glycine is an amino acid that has already been detected in space. It is relevant to estimate its resistance under cosmic radiation. In this way, a sublimate of glycine in α-form on KBr substrate was exposed in the laboratory to a 1.0 keV electron beam. The radiolysis study was performed at 40 K, 80 K, and 300 K sample temperatures. These temperatures were chosen to cover characteristics of the outer space environment. The evolution of glycine compaction and degradation was monitored in real time by infrared spectroscopy (Fourier-transform infrared) by investigation in the spectral ranges of 3500-2100, 1650-1200, and 950-750 cm-1. The compaction cross-section increases as the glycine temperature decreases. The glycine film thickness layer of ∼160 nm was depleted completely after ∼15 min at 300 K under irradiation with ∼1.4 µA beam current on the target, whereas the glycine depletion at 40 K and 80 K occurred after about 4 h under similar conditions. The destruction cross-section at room temperature is found to be (13.8 ± 0.2) × 10-17 cm2, that is, about 20 times higher than the values for glycine depletion at lower temperatures (<80 K). Emerging and vanishing peak absorbance related to OCN- and CO bands was observed in 2230-2100 cm-1 during the radiolysis at 40 K and 80 K. The same new IR bands appear in the range of 1600-1500, 1480-1370, and 1350-1200 cm-1 after total glycine depletion for all temperature configurations. A strong N-H deformation band growing at 1510 cm-1 was observed only at 300 K. Finally, the destruction cross-section associated to tholin decay at room temperature is estimated to be (1.30 ± 0.05) × 10-17 cm2. In addition, a correlation between the formation cross-sections for daughter and granddaughter molecules at 300 K is also obtained from the experimental data.


Assuntos
Elétrons , Glicina/efeitos da radiação , Temperatura , Cristalografia por Raios X , Glicina/química , Espectroscopia de Infravermelho com Transformada de Fourier , Fatores de Tempo
10.
Nanomaterials (Basel) ; 7(1)2017 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-28336845

RESUMO

Here, we investigate, through parametrically optimized macroscale simulations, the field electron emission from arrays of carbon nanotube (CNT)-coated Spindts towards the development of an emerging class of novel vacuum electron devices. The present study builds on empirical data gleaned from our recent experimental findings on the room temperature electron emission from large area CNT electron sources. We determine the field emission current of the present microstructures directly using particle in cell (PIC) software and present a new CNT cold cathode array variant which has been geometrically optimized to provide maximal emission current density, with current densities of up to 11.5 A/cm² at low operational electric fields of 5.0 V/µm.

11.
Nano Lett ; 17(4): 2319-2327, 2017 04 12.
Artigo em Inglês | MEDLINE | ID: mdl-28253617

RESUMO

Typical use of colloidal quantum dots (QDs) as bright, tunable phosphors in real applications relies on engineering of their surfaces to suppress the loss of excited carriers to surface trap states or to the surrounding medium. Here, we explore the utility of QDs in an application that actually exploits their propensity toward photoionization, namely within efficient and robust photocathodes for use in next-generation electron guns. In order to establish the relevance of QD films as photocathodes, we evaluate the efficiency of electron photoemission of films of a variety of compositions in a typical electron gun configuration. By quantifying photocurrent as a function of excitation photon energy, excitation intensity and pulse duration, we establish the role of hot electrons in photoemission within the multiphoton excitation regime. We also demonstrate the effect of QD structure and film deposition methods on efficiency, which suggests numerous pathways for further enhancements. Finally, we show that QD photocathodes offer superior efficiencies relative to standard copper cathodes and are robust against degradation under ambient conditions.

12.
Sensors (Basel) ; 11(5): 5202-14, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-22163896

RESUMO

We present a new compact electron gun based on the secondary emission through ionic bombardment principle. The driving parameters to develop such a gun are to obtain a quite small electron gun for an in-flight instrument performing Electron Beam Fluorescence measurements (EBF) on board of a reentry vehicle in the upper atmosphere. These measurements are useful to characterize the gas flow around the vehicle in terms of gas chemical composition, temperatures and velocity of the flow which usually presents thermo-chemical non-equilibrium. Such an instrument can also be employed to characterize the upper atmosphere if placed on another carrier like a balloon. In ground facilities, it appears as a more practical tool to characterize flows in wind tunnel studies or as an alternative to complex electron guns in industrial processes requiring an electron beam. We describe in this paper the gun which has been developed as well as its different features which have been characterized in the laboratory.


Assuntos
Elétrons , Armas de Fogo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA