Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 172.849
Filtrar
Mais filtros








Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-39144408

RESUMO

Objectives: We aimed to conduct a systematic review and meta-analysis to assess the value of image-enhanced endoscopy including blue laser imaging (BLI), linked color imaging, narrow-band imaging (NBI), and texture and color enhancement imaging to detect and diagnose gastric cancer (GC) compared to that of white-light imaging (WLI). Methods: Studies meeting the inclusion criteria were identified through PubMed, Cochrane Library, and Japan Medical Abstracts Society databases searches. The pooled risk ratio for dichotomous variables was calculated using the random-effects model to assess the GC detection between WLI and image-enhanced endoscopy. A random-effects model was used to calculate the overall diagnostic performance of WLI and magnifying image-enhanced endoscopy for GC. Results: Sixteen studies met the inclusion criteria. The detection rate of GC was significantly improved in linked color imaging compared with that in WLI (risk ratio, 2.20; 95% confidence interval [CI], 1.39-3.25; p < 0.01) with mild heterogeneity. Magnifying endoscopy with NBI (ME-NBI) obtained a pooled sensitivity, specificity, and area under the summary receiver operating curve of 0.84 (95 % CI, 0.80-0.88), 0.96 (95 % CI, 0.94-0.97), and 0.92, respectively. Similarly, ME-BLI showed a pooled sensitivity, specificity, and area under the curve of 0.81 (95 % CI, 0.77-0.85), 0.85 (95 % CI, 0.82-0.88), and 0.95, respectively. The diagnostic efficacy of ME-NBI/BLI for GC was evidently high compared to that of WLI, However, significant heterogeneity among the NBI studies still existed. Conclusions: Our meta-analysis showed a high detection rate for linked color imaging and a high diagnostic performance of ME-NBI/BLI for GC compared to that with WLI.

2.
J Environ Sci (China) ; 147: 512-522, 2025 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-39003067

RESUMO

To better understand the migration behavior of plastic fragments in the environment, development of rapid non-destructive methods for in-situ identification and characterization of plastic fragments is necessary. However, most of the studies had focused only on colored plastic fragments, ignoring colorless plastic fragments and the effects of different environmental media (backgrounds), thus underestimating their abundance. To address this issue, the present study used near-infrared spectroscopy to compare the identification of colored and colorless plastic fragments based on partial least squares-discriminant analysis (PLS-DA), extreme gradient boost, support vector machine and random forest classifier. The effects of polymer color, type, thickness, and background on the plastic fragments classification were evaluated. PLS-DA presented the best and most stable outcome, with higher robustness and lower misclassification rate. All models frequently misinterpreted colorless plastic fragments and its background when the fragment thickness was less than 0.1mm. A two-stage modeling method, which first distinguishes the plastic types and then identifies colorless plastic fragments that had been misclassified as background, was proposed. The method presented an accuracy higher than 99% in different backgrounds. In summary, this study developed a novel method for rapid and synchronous identification of colored and colorless plastic fragments under complex environmental backgrounds.


Assuntos
Monitoramento Ambiental , Aprendizado de Máquina , Plásticos , Espectroscopia de Luz Próxima ao Infravermelho , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Monitoramento Ambiental/métodos , Plásticos/análise , Análise dos Mínimos Quadrados , Análise Discriminante , Cor
3.
J Environ Sci (China) ; 148: 602-613, 2025 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-39095193

RESUMO

Airborne microplastics (MPs) are important pollutants that have been present in the environment for many years and are characterized by their universality, persistence, and potential toxicity. This study investigated the effects of terrestrial and marine transport of MPs in the atmosphere of a coastal city and compared the difference between daytime and nighttime. Laser direct infrared imaging (LDIR) and polarized light microscopy were used to characterize the physical and chemical properties of MPs, including number concentration, chemical types, shape, and size. Backward trajectories were used to distinguish the air masses from marine and terrestrial transport. Twenty chemical types were detected by LDIR, with rubber (16.7%) and phenol-formaldehyde resin (PFR; 14.8%) being major components. Three main morphological types of MPs were identified, and fragments (78.1%) are the dominant type. MPs in the atmosphere were concentrated in the small particle size segment (20-50 µm). The concentration of MPs in the air mass from marine transport was 14.7 items/m3 - lower than that from terrestrial transport (32.0 items/m3). The number concentration of airborne MPs was negatively correlated with relative humidity. MPs from terrestrial transport were mainly rubber (20.2%), while those from marine transport were mainly PFR (18%). MPs in the marine transport air mass were more aged and had a lower number concentration than those in the terrestrial transport air mass. The number concentration of airborne MPs is higher during the day than at night. These findings could contribute to the development of targeted control measures and methods to reduce MP pollution.


Assuntos
Poluentes Atmosféricos , Monitoramento Ambiental , Microplásticos , China , Microplásticos/análise , Poluentes Atmosféricos/análise , Cidades , Atmosfera/química , Tamanho da Partícula
4.
J Med Imaging (Bellingham) ; 12(Suppl 1): S13003, 2025 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-39055549

RESUMO

Purpose: Use of mechanical imaging (MI) as complementary to digital mammography (DM), or in simultaneous digital breast tomosynthesis (DBT) and MI - DBTMI, has demonstrated the potential to increase the specificity of breast cancer screening and reduce unnecessary biopsies compared with DM. The aim of this study is to investigate the increase in the radiation dose due to the presence of an MI sensor during simultaneous image acquisition when automatic exposure control is used. Approach: A radiation dose study was conducted on clinically available breast imaging systems with and without an MI sensor present. Our estimations were based on three approaches. In the first approach, exposure values were compared in paired clinical DBT and DBTMI acquisitions in 97 women. In the second approach polymethyl methacrylate (PMMA) phantoms of various thicknesses were used, and the average glandular dose (AGD) values were compared. Finally, a rectangular PMMA phantom with a 45 mm thickness was used, and the AGD values were estimated based on air kerma measurements with an electronic dosemeter. Results: The relative increase in exposure estimated from digital imaging and communications in medicine headers when using an MI sensor in clinical DBTMI was 11.9 % ± 10.4 . For the phantom measurements of various thicknesses of PMMA, the relative increases in the AGD for DM and DBT measurements were, on average, 10.7 % ± 3.1 and 11.4 % ± 3.0 , respectively. The relative increase in the AGD using the electronic dosemeter was 11.2 % ± < 0.001 in DM and 12.2 % ± < 0.001 in DBT. The average difference in dose between the methods was 11.5 % ± 3.3 . Conclusions: Our measurements suggest that the use of simultaneous breast radiography and MI increases the AGD by an average of 11.5 % ± 3.3 . The increase in dose is within the acceptable values for mammography screening recommended by European guidelines.

5.
J Biomed Opt ; 30(Suppl 1): S13703, 2025 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-39034959

RESUMO

Significance: Standardization of fluorescence molecular imaging (FMI) is critical for ensuring quality control in guiding surgical procedures. To accurately evaluate system performance, two metrics, the signal-to-noise ratio (SNR) and contrast, are widely employed. However, there is currently no consensus on how these metrics can be computed. Aim: We aim to examine the impact of SNR and contrast definitions on the performance assessment of FMI systems. Approach: We quantified the SNR and contrast of six near-infrared FMI systems by imaging a multi-parametric phantom. Based on approaches commonly used in the literature, we quantified seven SNRs and four contrast values considering different background regions and/or formulas. Then, we calculated benchmarking (BM) scores and respective rank values for each system. Results: We show that the performance assessment of an FMI system changes depending on the background locations and the applied quantification method. For a single system, the different metrics can vary up to ∼ 35 dB (SNR), ∼ 8.65 a . u . (contrast), and ∼ 0.67 a . u . (BM score). Conclusions: The definition of precise guidelines for FMI performance assessment is imperative to ensure successful clinical translation of the technology. Such guidelines can also enable quality control for the already clinically approved indocyanine green-based fluorescence image-guided surgery.


Assuntos
Benchmarking , Imagem Molecular , Imagem Óptica , Imagens de Fantasmas , Razão Sinal-Ruído , Imagem Molecular/métodos , Imagem Molecular/normas , Imagem Óptica/métodos , Imagem Óptica/normas , Processamento de Imagem Assistida por Computador/métodos
6.
Artigo em Inglês | MEDLINE | ID: mdl-38746904

RESUMO

Image-enhanced endoscopy (IEE) has advanced gastrointestinal disease diagnosis and treatment. Traditional white-light imaging has limitations in detecting all gastrointestinal diseases, prompting the development of IEE. In this review, we explore the utility of IEE, including texture and color enhancement imaging and red dichromatic imaging, in pancreatobiliary (PB) diseases. IEE includes methods such as chromoendoscopy, optical-digital, and digital methods. Chromoendoscopy, using dyes such as indigo carmine, aids in delineating lesions and structures, including pancreato-/cholangio-jejunal anastomoses. Optical-digital methods such as narrow-band imaging enhance mucosal details and vessel patterns, aiding in ampullary tumor evaluation and peroral cholangioscopy. Moreover, red dichromatic imaging with its specific color allocation, improves the visibility of thick blood vessels in deeper tissues and enhances bleeding points with different colors and see-through effects, proving beneficial in managing bleeding complications post-endoscopic sphincterotomy. Color enhancement imaging, a novel digital method, enhances tissue texture, brightness, and color, improving visualization of PB structures, such as PB orifices, anastomotic sites, ampullary tumors, and intraductal PB lesions. Advancements in IEE hold substantial potential in improving the accuracy of PB disease diagnosis and treatment. These innovative techniques offer advantages paving the way for enhanced clinical management of PB diseases. Further research is warranted to establish their standard clinical utility and explore new frontiers in PB disease management.

7.
Artigo em Inglês | MEDLINE | ID: mdl-38725874

RESUMO

Objective: Iodine staining on white light imaging (WLI) is the gold standard for detecting and demarcating esophageal squamous cell carcinoma (ESCC). We examined the effects of texture and color enhancement imaging (TXI) on improving the endoscopic visibility of ESCC under iodine staining. Methods: Twenty ESCC lesions that underwent endoscopic submucosal dissection were retrospectively included. The color difference between ESCC and the surrounding mucosa (ΔEe) on WLI, TXI, and narrow-band imaging was assessed, and ΔEe under 1% iodine staining on WLI and TXI. Furthermore, the visibility grade determined by endoscopists was evaluated on each imaging. Result: The median ΔEe was greater on TXI than on WLI (14.53 vs. 10.71, respectively; p < 0.005). Moreover, the median ΔEe on TXI under iodine staining was greater than the median ΔEe on TXI and narrow-band imaging (39.20 vs. 14.53 vs. 16.42, respectively; p < 0.005 for both). A positive correlation in ΔEe under iodine staining was found between TXI and WLI (correlation coefficient = 0.61, p < 0.01). Moreover, ΔEe under iodine staining on TXI in each lesion was greater than the corresponding ΔEe on WLI. The visibility grade assessed by endoscopists on TXI was also significantly greater than that on WLI under iodine staining (p < 0.01). Conclusions: The visibility of ESCC after iodine staining was greater on TXI than on WLI.

8.
Artigo em Inglês | MEDLINE | ID: mdl-38725875

RESUMO

Accurate measurement of the size of lesions or distances between any two points during endoscopic examination of the gastrointestinal tract is difficult owing to the fisheye lens used in endoscopy. To overcome this issue, we developed a phase-shift method to measure three-dimensional (3D) data on a curved surface, which we present herein. Our system allows the creation of 3D shapes on a curved surface by the phase-shift method using a stripe pattern projected from a small projecting device to an object. For evaluation, 88 measurement points were inserted in porcine stomach tissue, attached to a half-pipe jig, with an inner radius of 21 mm. The accuracy and precision of the measurement data for our shape measurement system were compared with the data obtained using an Olympus STM6 measurement microscope. The accuracy of the path length of a simulated protruded lesion was evaluated using a plaster model of the curved stomach and graph paper. The difference in height measures between the measurement microscope and measurement system data was 0.24 mm for the 88 measurement points on the curved surface of the porcine stomach. The error in the path length measurement for a lesion on an underlying curved surface was <1% for a 10-mm lesion. The software was developed for the automated calculation of the major and minor diameters of each lesion. The accuracy of our measurement system could improve the accuracy of determining the size of lesions, whether protruded or depressed, regardless of the curvature of the underlying surface.

9.
Artigo em Inglês | MEDLINE | ID: mdl-38817687

RESUMO

Objective: A newly launched endoscopy system (EVIS X1, CV-1500; Olympus) is equipped with texture and color enhancement imaging (TXI). We aimed to investigate the efficacy of TXI for the visibility and diagnostic accuracy of non-polypoid colorectal lesions. Methods: We examined 100 non-polypoid lesions in 42 patients from the same position, angle, and distance of the view in three modes: white light imaging (WLI), narrow-band imaging (NBI), and TXI. The primary outcome was to compare polyp visibility in the three modes using subjective polyp visibility score and objective color difference values. The secondary outcome was to compare the diagnostic accuracy without magnification. Results: Overall, the visibility score of TXI was significantly higher than that of WLI (3.7 ± 1.1 vs. 3.6 ± 1.1; p = 0.008) and lower than that of NBI (3.7 ± 1.1 vs. 3.8 ± 1.1; p = 0.013). Color difference values of TXI were higher than those of WLI (11.5 ± 6.9 vs. 9.1 ± 5.4; p < 0.001) and lower than those of NBI (11.5 ± 6.9 vs. 13.1 ± 7.7; p = 0.002). No significant differences in TXI and NBI (visibility score: 3.7 ± 1.0 vs. 3.8 ± 1.1; p = 0.833, color difference values: 11.6 ± 7.1 vs. 12.9 ± 8.3; p = 0.099) were observed for neoplastic lesions. Moreover, the diagnostic accuracy of TXI was significantly higher than that of NBI (65.5% vs. 57.6%, p = 0.012) for neoplastic lesions. Conclusions: TXI demonstrated higher visibility than that of WLI and lower than that of NBI. Further investigations are warranted to validate the performance of the TXI mode comprehensively.

10.
J Med Radiat Sci ; 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-39217463

RESUMO

INTRODUCTION: Radiography students complete professional placements in various clinical settings and must adhere to distinct infection prevention and control (IPC) protocols. The aim of this study was to explore radiography students' training, knowledge, attitudes, and practice (KAP) relating to IPC in the use of contrast media injectors in computed tomography (CT). METHODS: An online survey study was undertaken with radiography students enrolled at two Australian universities. Survey questions related to contrast media training and KAP regarding IPC in CT. Data was summarised using descriptive statistics, with comparisons between experience in public and private practice. One free-text response question focused on non-adherence to IPC best practice, analysed using content analysis. RESULTS: In total, 40 students completed the survey (9% response rate). Reports of IPC and contrast media equipment training was high, with disposition for further training. Regarding IPC knowledge, 65% of students responded correctly to all 'knowledge' items (individual scores range: 60-100%). Low consensus was observed regarding whether gloves replace the need for hand hygiene and if CT contrast tubing poses risk to healthcare workers (85% each). Mean scores ranged from 41% to 100% regarding identification of sterile syringe and tubing components. Responses to the open-ended question were categorised into four themes: 'High non-adherence risk working conditions', 'attitudes and practice', 'knowledge', and 'prioritise good IPC practice'. CONCLUSIONS: Radiography students demonstrate varied comprehension of IPC regarding contrast media equipment, and results suggest need for collaborative efforts between academic institutions and clinical training sites to integrate IPC protocols into curricula and on-site training.

11.
Can J Urol ; 31(4): 11955-11962, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39217520

RESUMO

INTRODUCTION: Most men diagnosed with very-low and low-risk prostate cancer are candidates for active surveillance; however, there is still a misclassification risk. We examined whether PI-RADS category 4 or 5 combined with ISUP 1 on prostate biopsy predicts upgrading and/or adverse pathology at radical prostatectomy. MATERIALS AND METHODS: A total of 127 patients had ISUP 1 cancer on biopsy after multiparametric MRI (mpMRI) and then underwent radical prostatectomy. We then evaluated them for ISUP upgrading and/or adverse pathology on radical prostatectomy. RESULTS: Eight-nine patients (70%) were diagnosed with PI-RADS 4 or 5 lesions. ISUP upgrading was significantly higher among patients with PI-RADS 4-5 lesions (84%) compared to patients with equivocal or non-suspicious mpMRI findings (26%, p < 0.001). Both PI-RADS 4-5 lesions (OR 24.3, 95% CI 7.3, 80.5, p < 0.001) and stage T2 on DRE (OR 5.9, 95% CI 1.2, 29.4, p = 0.03) were independent predictors of upgrading on multivariate logistic regression analysis. Men with PI-RADS 4-5 lesions also had significantly more extra-prostatic extension (51% vs. 3%, p < 0.001) and positive surgical margins (16% vs. 3%. p = 0.03). The only independent predictor of adverse pathology was PI-RADS 4-5 (OR 21.7, 95% CI 4.8, 99, p < 0.001). CONCLUSION: PI-RADS 4 or 5 lesions on mpMRI were strong independent predictors of upgrading and adverse pathology. Incorporating mpMRI findings when selecting patients for active surveillance must be further evaluated in future studies.


Assuntos
Imageamento por Ressonância Magnética Multiparamétrica , Prostatectomia , Neoplasias da Próstata , Humanos , Masculino , Neoplasias da Próstata/patologia , Neoplasias da Próstata/cirurgia , Neoplasias da Próstata/diagnóstico por imagem , Prostatectomia/métodos , Pessoa de Meia-Idade , Idoso , Valor Preditivo dos Testes , Gradação de Tumores , Próstata/patologia , Próstata/diagnóstico por imagem , Estudos Retrospectivos , Biópsia , Estadiamento de Neoplasias , Imageamento por Ressonância Magnética , Conduta Expectante , Medição de Risco
12.
Talanta ; 280: 126779, 2024 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-39217713

RESUMO

Sensitive monitoring of human 8-oxyguanine DNA glycosylase (hOGG1) activity in living cells is helpful to understand its function in damage repair and evaluate its role in disease diagnosis. Herein, a functional DNA-Zn2+ coordination nanospheres was proposed for sensitive imaging of hOGG1 in living cells. The nanospheres were constructed through the coordination-driven self-assembly of the entropy driven reaction (EDR) -deoxyribozyme (DNAzyme) system with Zn2+, where DNAzyme was designed to split structure and assembled into the EDR system. When the nanospheres entered the cell, the competitive coordination between phosphate in the cell and Zn2+ leaded to the disintegration of the nanospheres, releasing DNA and some Zn2+. The released Zn2+ acted as a cofactor of DNAzyme. In the presence of hOGG1, the EDR was completed, accompanied by fluorescence recovery and the generation of a complete DNAzyme. With the assistance of Zn2+, DNAzyme continuously cleaved substrates to produce plenty of fluorescence signals, thus achieving sensitive imaging of hOGG1 activity. The nanospheres successfully achieved sensitive imaging of hOGG1 in human cervical cancer cells (HeLa), human non-small cell lung cancer cells and human normal colonic epithelial cells, and assayed changes in hOGG1 activity in HeLa cells. This nanospheres may provide a new tool for intracellular hOGG1 imaging and related biomedical studies.

13.
Parkinsonism Relat Disord ; 127: 107117, 2024 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-39217795

RESUMO

INTRODUCTION: The a-Synuclein Origin and Connectome (SOC) model of Lewy body diseases postulates that a-syuclein will be asymmetrically distributed in some patients with Lewy body diseases, potentially leading to asymmetric neuronal dysfunction and symptoms. METHODS: We included two patient groups: 19 non-demented Parkinson's disease (nPD) patients with [18F]FDG PET and motor symptoms assessed by UPDRS-III, and 65 Lewy body dementia (LBD) patients with [18F]FDG PET and dopamine radioisotope imaging. Asymmetry indices were calculated for [18F]FDG PET by including the cortex for each hemisphere, for dopamine radioisotope imaging by including the putamen and caudate separately, and for motor symptoms by using the difference between right-left UPDRS-III score. Correlations between these asymmetry indices were explored to test the predictions of the SOC model. To identify cases with a more typical LBD imaging profile, we calculated a Cingulate Island Sign (CIS) index on the [18F]FDG PET image. RESULTS: We found a significant correlation between cortical interhemispheric [18F]FDG asymmetry and motor-symptom asymmetry in nPD patients (r = 0.62, P = 0.004). In patients with LBD, we found a significant correlation between cortical interhemispheric [18F]FDG asymmetry and dopamine transporter asymmetry in the caudate (r = 0.37, P = 0.0019), but not in the putamen (r = 0.15, P = 0.22). We observed that the correlation in the caudate was stronger in LBD subjects with the highest CIS index, i.e., with more typical LBD imaging profiles. CONCLUSION: Our study partly supports the SOC model, but further investigations are needed - ideally of de novo, non-demented PD patients.

14.
Transl Oncol ; 49: 102115, 2024 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-39217852

RESUMO

OBJECTIVE: To demonstrate the feasibility of using focused ultrasound to enhance delivery of PD-1 inhibitors in glioma rats and determine if such an approach increases treatment efficacy. METHODS: C6 glioma in situ rat model was used in this study. Transcranial irradiation with FUS combined with microbubbles was administered to open the blood-brain barrier (BBB). The efficacy of BBB opening was evaluated in normal rats. The rats with glioma were grouped to evaluate the role of PD-1 inhibitors combined with FUS-induced immune responses in suppressing glioma when the BBB opens. Flow cytometry was used to examine the changes of immune cell populations of lymphocytes in peripheral blood, tumor tissue and spleen tissue of the rats. A section of rat brain tissue was also used for histological and immunohistochemical analysis. The survival of the rats was then monitored; the tumor progression and changes in blood perfusion of tumor were dynamically observed in vivo using multimodal MRI. RESULTS: FUS combined with microbubbles could enhance the blood perfusion of tumors by increasing the permeability of BBB (p < 0.0001), thus promoting the infiltration of CD4+ T lymphocytes (p < 0.01). Compared with the control group, the combination treatment group had increased in the infiltration number of CD4+(p < 0.05) and CD8+ T (p < 0.05); the tumor volume of the combined treatment group was smaller than that of the control group (p < 0.01) and the survival rate of the rats was prolonged (p < 0.05). CONCLUSIONS: In this study, we demonstrated that the transient opening of the BBB induced by FUS enhanced tumor vascular perfusion and facilitated the delivery of PD-1 inhibitors, ultimately improving the therapeutic efficacy for glioblastoma.

15.
J Hazard Mater ; 479: 135694, 2024 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-39217944

RESUMO

Mercury ion (Hg2+) is considered a harmful neurotoxin, and real-time monitoring of Hg2+ concentrations in environmental and biological samples is critical. Fluorescent probes are a rapidly emerging visualization tool owing to their simple design and good selectivity. Herein, a novel fluorescence (FL) probe 2-(4-((6-((quinolin-8-yloxy)methyl)pyridin-2-yl)methyl)piperazin-1-yl)anthracene-9,10-dione (QPPA) is designed using piperazine as a linker between the anthraquinone group, which serves as a fluorophore, and N4O as the Hg2+ ligand. The probe exhibits FL "turn-on" sensing of Hg2+ because the complex inhibits the photo-induced electron transfer (PET) process. Moreover, QPPA can overcome the invasion by other possible cations, resulting in a clear color change from orange to colorless with the addition Hg2+. The chelation of QPPA with Hg2+ in a 1:1 ratio. Subsequently, the theoretically determined binding sites of the ligand to Hg2+ are validated through 1H NMR titration. The in situQPPA-Hg2+ complex can be subjected to Hg2+ extraction following the introduction of S2- owing to its robust binding capacity. The exceptional limit of detection values for Hg2+ and S2- are obtained as 63.0 and 79.1 nM (S/N = 3), respectively. Moreover, QPPA can display bright red FL in the presence of Hg2+ in different biological specimens such as HeLa cells, zebrafish, onion root tip tissues, and water flea Daphnia carinata, further providing an effective strategy for environmental monitoring and bioimaging of Hg2+ in living organisms.

16.
Spectrochim Acta A Mol Biomol Spectrosc ; 325: 125068, 2024 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-39217956

RESUMO

Hyperspectral camera technology is advancing rapidly, and this paper seeks to compare a state-of-the-art industrial dual-camera setup to a single-camera system employing the latest chip technology (IMX990 from Sony). The hyperspectral cameras are compared over both the Visual and Short-Wave Infrared range (400-1700 nm) of the electromagnet spectrum. The spectral range and resolution, as well as spatial parameters and spectroscopic information are quantified with comparable optics, electronics, and test targets. Generally, enhanced spectral detail and reduced noise were observed for the single-camera compared to its peers. Thus, the IMX990 shows promising performance for the new generation of hyperspectral cameras directly relevant to industrial applications, such as detection, documentation, and sorting.

17.
Spectrochim Acta A Mol Biomol Spectrosc ; 325: 124986, 2024 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-39217960

RESUMO

Near-infrared (NIR) fluorophores have promoted the development of materials for bioimaging, but traditional NIR dyes usually suffer from aggregation-caused quenching (ACQ), impeding their applications. Herein, we propose two difluoroboron ß-diketonate complexes TBO and TBS, consisting a donor-acceptor (D-A) structure with triphenylamine (TPA) moiety as an electron donors and difluoroboron as well as furan or thiophene building block as an electron acceptor. The theoretical calculation and optical data shows that both of them have intramolecular charge transfer (ICT) characteristics. Such ICT characteristics endow them with both solvatochromism and dual-state emission (DSE) properties. In the solvent CH2Cl2, the emission wavelength of TBO ranges from 550 nm to 750 nm, with a low fluorescence quantum yield (Φ = 7.0 %). However, in the less polar solvent hexane, the emission wavelength blue-shifts, with an increased Φ reaching up to 18 %. Moreover, TBO and TBS exhibit mechanochromic characteristics and rare multi-channel fluorescence emission phenomena at solid-state. Their solid-state samples can emit fluorescence in four spectral bands with maximum emission wavelengths at 300 nm, 400 nm, 600 nm, and 770 nm under excitation at 240 nm. These unique optical properties are expected to be utilized for detecting polarity of system and deformation. Moreover, according to the results of cell imaging and flow cytometry, TBO molecular were easily internalized into Hela cells and distributed in the cytoplasm with strong red fluorescence. Therefore, this research inspires more insight into development of NIR luminogens for biomedical imaging.

18.
Prog Retin Eye Res ; : 101292, 2024 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-39218142

RESUMO

Optical coherence tomography angiography (OCTA) has transformed ocular vascular imaging, revealing microvascular changes linked to various systemic diseases. This review explores its applications in diabetes, hypertension, cardiovascular diseases, and neurodegenerative diseases. While OCTA provides a valuable window into the body's microvasculature, interpreting the findings can be complex. Additionally, challenges exist due to the relative non-specificity of its findings where changes observed in OCTA might not be unique to a specific disease, variations between OCTA machines, the lack of a standardized normative database for comparison, and potential image artifacts. Despite these limitations, OCTA holds immense potential for the future. The review highlights promising advancements like quantitative analysis of OCTA images, integration of artificial intelligence for faster and more accurate interpretation, and multi-modal imaging combining OCTA with other techniques for a more comprehensive characterization of the ocular vasculature. Furthermore, OCTA's potential future role in personalized medicine, enabling tailored treatment plans based on individual OCTA findings, community screening programs for early disease detection, and longitudinal studies tracking disease progression over time is also discussed. In conclusion, OCTA presents a significant opportunity to improve our understanding and management of systemic diseases. Addressing current limitations and pursuing these exciting future directions can solidify OCTA as an indispensable tool for diagnosis, monitoring disease progression, and potentially guiding treatment decisions across various systemic health conditions.

19.
J Vasc Surg ; 2024 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-39218239

RESUMO

OBJECTIVE: Recent randomized controlled trials have demonstrated a notable prevalence of immediate technical failures (ITFs) in percutaneous vascular interventions (PVIs) for complex arterial lesions associated with chronic limb-threatening ischemia (CLTI). Current imaging modalities present inherent limitations in identifying these lesions, making it challenging to determine the most suitable candidates for PVI. We present a novel preprocedural magnetic resonance imaging (MRI) histology protocol for identifying lesions that might present a higher rate of immediate and mid-term PVI failure. METHODS: 22 patients (13 females, average age 65.8±9.72 years) scheduled for PVI were prospectively enrolled and underwent 3T MRI using ultrashort echo time and 'Steady-State Free Precession' contrasts to characterize target lesions prior to PVI. Lesions were scored as 'hard' if >50% of the lumen was occluded by hard components (calcium/dense collagen) on MRI in the hardest cross-section. Two readers evaluated MRI datasets. TASC/GLASS/WIFi scoring was performed based on intraprocedural angiograms and chart review. The relationship between MRI scoring, TASC/GLASS scoring and procedural outcomes was investigated using univariate analysis. Mid-term follow-up (revascularization and amputation rate) was recorded at 3 months and 6 months, post-intervention. RESULTS: Our cohort of 22 patients yielded 40 target lesions. 5 lesions were excluded (2 non-diagnostic image quality, 3 PVIs were ultimately diagnostic only). 6 lesions (17%) were scored as 'hard'. MRI-scored 'hard' lesions had higher proportion of ITF ('hard' vs 'soft' 83% (n/N=5/6) vs. 3% (n/N=1/29), p<.001). 'Hard' versus 'soft' MRI scoring was the only factor significantly associated with immediate PVI technical success (p < .001), as opposed to TASC/GLASS scoring. Both at 3 months and 6 months after PVI, the re-intervention rate was significantly higher among those lesions which were scored 'hard' on MRI (3-month: hard: 80% vs. soft: 16%, p =.011 6-month: hard: 80%, soft: 27%, p=.047). CONCLUSIONS: MRI histology could be a valuable tool for optimizing PVI patient selection and treatment strategies.

20.
Neurosci Lett ; : 137959, 2024 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-39218293

RESUMO

Understanding the sequence of cellular responses and their contributions to pathomorphogical changes in spinal white matter injuries is a prerequisite for developing efficient therapeutic strategies for spinal cord injury (SCI) as well as neurodegenerative and inflammatory diseases of the spinal cord such as amyotrophic lateral sclerosis and multiple sclerosis. We have developed several types of surgical procedures suitable for acute one-time and chronic recurrent in vivo multiphoton microscopy of spinal white matter [1]. Sophisticated surgical procedures were combined with transgenic mouse technology to image spinal tissue labeled with up to four fluorescent proteins (FPs) in axons, astrocytes, microglia, and blood vessels. To clearly separate the simultaneously excited FPs, spectral unmixing including iterative procedures was performed after imaging the diversely labeled spinal white matter with a custom-made 4-channel two-photon laser-scanning microscope. In our longitudinal multicellular studies of injured spinal white matter, we imaged axonal dynamics and invasion of microglia and astrocytes for a time course of over 200 days after SCI. Our methods offer ideal platforms for investigating acute and chronic cellular dynamics, cell-cell interactions, and metabolite fluctuations in health and disease as well as pharmacological manipulations in vivo.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA