Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.384
Filtrar
1.
Arthroplast Today ; 28: 101469, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39100424

RESUMO

Background: Physician patients requiring surgery present with occupational risks and personality traits that may affect outcomes. This study compared implant survivorship, complications, and clinical outcomes of physicians undergoing primary total hip arthroplasty (THA) or total knee arthroplasty (TKA). Methods: A retrospective review of our institutional total joint registry identified 185 physicians undergoing primary THA (n = 94) or TKA (n = 91). Physicians were matched 1:2 with nonphysician controls according to age, sex, body mass index, joint (hip or knee), and surgical year. Physician type (medical, n = 132 vs surgical, n = 53) subanalysis was performed. Implant survivorship was assessed via Kaplan-Meier methods. Clinical outcomes were evaluated by Harris hip scores and Knee Society Scores. Mean follow-up was 5 years. Results: There was no significant difference in 5-year implant survivorship free of any reoperation (P > .5) or any revision (P > .2) between physician and nonphysician patients after THA and TKA. Similarly, the 90-day complication risk was not significantly different after THA or TKA (P = 1.0 for both). Physicians and nonphysicians demonstrated similar improvement in Harris hip scores (P = .6) and Knee Society Scores (P = .4). When comparing physician types, there was no difference in implant survivorship (P > .4), complications (P > .6), or patient reported outcomes (P > .1). Conclusions: Physician patients have similar implant survivorship, complications, and clinical outcomes when compared to nonphysicians after primary THA and TKA. Physicians should feel reassured that their profession does not appear to increase risks when undergoing lower extremity total joint arthroplasty.

2.
S Afr J Physiother ; 80(1): 2027, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39114425

RESUMO

Background: Knee replacement surgery can significantly improve the quality of life of patients with severe knee osteoarthritis. Equitable access to knee replacement surgery is important to ensure that everyone, regardless of their socioeconomic status or geographical location, have fair and timely access. Objectives: The aim of our study was to (1) describe the health equity profile and quality of life of patients awaiting knee replacement at a single academic hospital in South Africa and to (2) describe the association between these health equity factors and the waiting time. Method: A cross-sectional survey and retrospective record review of patients awaiting knee replacement was conducted using the PROGRESS-Plus health equity framework. Chi-square statistics were used to calculate association between health equity factors and the waiting time. Results: Three-hundred and two (N = 302) patients (77% female; mean age 67 years) participated, of whom one in three patients waited 5 years or longer for surgery. Elderly patients (> 70 years) and patients from lower socio-economic background were less likely to have equitable access to surgery. Conclusion: The current screening protocol for knee replacement surgery in the public health care sector does not provide equitable access to surgery. A more holistic screening approach alongside selective surgical prioritisation and rehabilitation could reduce the waiting list and facilitate equitable access to care. Clinical implications: Health equity factors such as socioeconomic status, age, and other patient characteristics such as life roles and employability should be taken into consideration when screening patients for elective knee replacement waiting lists.

3.
Ann Jt ; 9: 25, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39114421

RESUMO

Background and Objective: Knee replacement following anterior cruciate ligament (ACL) reconstruction can be demanding due to altered anatomy, soft tissue scars, bone loss, extensor mechanism complications, and knee instability. This narrative review summarizes the strategies and approaches to managing operative challenges in total knee arthroplasty (TKA) following ACL reconstruction. Methods: Studies reporting outcomes of patients who underwent TKA after ACL reconstruction were retrieved and assessed to be included in this review that synthesizes the available evidence highlighting the pitfalls encountered during surgery, the intraoperative challenges posed by ligament balancing and exposure, and the leading role of modular and retained implants. Key Content and Findings: TKA following ACL reconstruction has a high rate of intra-operative complications such as instability, bone loss, difficult exposure and demanding soft tissue balancing, representing a revision surgery rather than routine primary knee arthroplasty and a revision-oriented skill set and modular components are recommended to significantly optimize both surgical strategy and patient outcomes. With a rising incidence of ACL injuries and growing reconstructions, anticipating an increase in TKA procedures, this review aims to provide a call for rethinking clinical approaches to ensure effective and patient-centric care. Conclusions: This narrative review seems to indicate that TKA after ACL reconstruction should be considered as revision surgery and modular components should be used. However, future prospective and high-quality studies are required to better clarify risk factors and give strong recommendations for this complex surgery.

4.
Clinicoecon Outcomes Res ; 16: 537-545, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39130106

RESUMO

Objective: The objective of the analysis presented is to assess the efficacy of a fast-track pathway for elective hip and knee arthroplasty, compared to the traditional approach, adopted within a research hospital located in Milan (Italy), in terms of length of stay reduction and related direct medical costs. Methods: A monocentric observational retrospective study was implemented considering adult subjects who underwent elective primary total hip or knee replacement, with a diagnosis of primary or secondary osteoarthritis. Exclusion criteria were subjects admitted via emergency department, subjects undergoing knee or hip replacement because of fractures or prosthesis revision. The analysis compared the length of stay and the direct medical costs, assuming the hospital perspective, of subjects admitted in the pre-fast-track period (years 2016/2017) and during the fast-track period (years 2018/2019). Results: Knee replacement mean costs are 5,599 € (±1,158.3 €) in the pre-fast-track period and 4,487 € (±978.4 €) in the fast-track period (-1,112 €; -19.9%). Hip replacement mean costs in the pre-fast-track period are 5,364 € (±1,037.2 €) and 4,450 € (±843.7 €) in the fast-track period (-914 €; -17.0%). The adoption of fast-track pathway led to a statistically significant decrease of days of hospitalization of -2.8 (-37.6%) in knee replacement and of -2.9 (-39.2%) in hip replacement. Conclusion: The fast-track pathway adopted proved to be effective, reducing patients' length of stay, and sustainable and efficient, reducing direct medical costs, for both elective hip and knee replacement surgeries.

5.
Indian J Orthop ; 58(8): 1109-1117, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39087033

RESUMO

Background: The use of robotic-assisted total knee arthroplasty (RA-TKA) is gaining traction. There is evidence to suggest that RA-TKA can help to optimize the precision and accuracy of implant positioning and that there may be protective effects on surrounding bony and soft tissues. Yet, there are important differences between the various RA-TKA systems currently on the market. One such newly introduced RA-TKA system uses imageless technology and performs bony cuts with the use of a burr-based device. The learning curve and complications unique to this system have yet to be assessed. Methods: We evaluated 500 consecutive RA-TKA cases using a newly developed burr-based and imageless system which were done by a single surgeon between the months of October 2021 and February 2023. Operative times were recorded and compared to the previous 150 conventional TKA cases allowing for the learning curve to be calculated using the CUSUM method. Intraoperative and postoperative complications were categorically profiled. Results: The learning curve of this RA-TKA system was found to be 6 cases. Intraoperative complications included unintended bony over resection (n = 3), soft tissue injury (n = 2), and robotic system hardware (n = 2) or software (n = 2) malfunction. Postoperative complications consisted of superficial pin site infection (n = 1) and periprosthetic fracture near the pin sites (n = 1). There were no identified cases of prosthetic joint infection, instability events, or wound complications. Conclusions: The learning curve and the complication profile of a newly introduced imageless and burr-based RA-TKA system were described. This information serves to guide surgeons in adopting this technology and can counsel them regarding the potential pitfalls and challenges associated with its integration into practice. The work sheds light on the complexity and learning curve of the recently released imageless burr-based RA-TKA system. This important information is intended to help surgeons accept this cutting-edge technology by providing advice on any errors and difficulties that can occur when integrating it into clinical practice. This information can help surgeons navigate the complexities of integrating this new burr-based robotic technology into knee replacement procedures, enabling them to make well-informed decisions and receive guidance.

6.
Cureus ; 16(7): e64517, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39139322

RESUMO

BACKGROUND: Total knee replacement (TKR) is a common surgical solution for severe osteoarthritis. Kinematic alignment (KA) and mechanical alignment (MA) are two popular techniques. There is ongoing debate over the optimal method, influenced by varying long-term results and a scarcity of data on short-term postoperative outcomes. Early evaluation of these techniques is vital for improving rehabilitation outcomes and ensuring patient satisfaction.  Methods: This study retrospectively analyzed outcomes from 71 KA-TKRs and 85 MA-TKRs performed between 2019 and 2021. Knee flexion, visual analog scale (VAS) scores, EuroQol-5d (EQ-5d) quality of life measures, and dependence on walking aids were evaluated. Evaluations were conducted at baseline, six-weeks, three-months, and 12-months postoperatively using two-sample t-tests for continuous data and Pearson's chi-squared test for categorical data. RESULTS: At six-weeks and three-months postoperatively, the KA group exhibited significantly better outcomes in knee flexion (98.6° vs. 90.2° at six-weeks; 114.7° vs. 94.2° at three-months), pain management, and reduced walking aids compared to the MA group. By 12-months, these differences were no longer significant, with both groups showing comparable results in knee flexion, pain scores, and patient-reported outcomes.  Conclusion: KA offers substantial short-term advantages over MA for pain relief, increased knee flexion, and independence from walking aids. However, these benefits do not persist at one-year post-surgery, indicating a convergence of outcomes between the two techniques. Larger studies with extended follow-ups are required to determine the long-term implications of these alignment strategies.

7.
Arthroplast Today ; 28: 101399, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39139362

RESUMO

Background: One of the most debated topics in modern total knee arthroplasty (TKA) is the impact of metal hypersensitivity (MH) as a potential cause of prosthesis failure. Implanting hypoallergenic prostheses to avoid potential problems in suspected cases of MH is one treatment option that can be used in such cases. However, their long-term clinical safety and efficacy are not well proven. Methods: All literature relevant to modern hypoallergenic implants were reviewed and summarized to provide a comprehensive synopsis. In addition, a detailed literature search was performed on PUBMED, MEDLINE, and Google Scholar to identify all the clinical studies reporting outcomes for hypoallergenic knee implants. Our search was confined to those studies published as full manuscripts in the English language from July 2018 to July 2023. Results: To minimize the risk of MH, new implant variants have been developed which are either under clinical evaluation or in routine clinical use. These include conventional metal implants with protective coatings (mono- or multilayer) and metal-free implants. However, there is insufficient clinical data to confirm the rationale and effectiveness of using these "hypoallergenic" TKA implants. Conclusions: Published studies and arthroplasty registry data analyses indicate no significant differences between hypoallergenic and standard TKAs with overall good survival rates. In the future, further high-quality studies are needed to better understand the complexity of this subject.

8.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-39094931

RESUMO

BACKGROUND AND OBJECTIVES: It has been shown that total knee replacement improves functional capacity and physical activity; however, the influence of age remains unclear. The objective is evaluate the pre and postoperative physical activity measured with the Knee Society Score (KSS) score and the Tegner score. MATERIALS AND METHODS: A retrospective cohort analysis was conducted on patients who underwent total knee replacement (TKR) between January 2016 and December 2019 at our institution. Demographic variables (age, sex, and body mass index), activities of daily living, age-adjusted Charlson Comorbidity Index, American Society of Anesthesiologists score, the Knee Society Score (KSS) in its clinical (KSSc) and functional (KSSf) subscales, the Tegner functional scale, activity variables from the 2011 KSS version, and pain assessment using the visual analog scale were collected. Differences in these variables were analyzed between two age groups: Group A (between 65 and 79 years old) and Group B (80 years or older). RESULTS: A total of 450 patients were evaluated (Group A=245, Group B=167). Group A showed a Tegner improvement of 1.19 (95% CI 1.06/1.31), whereas Group B averaged 0.61 (95% CI 0.43/0.80) (p<0.001). Age >80 was an independent risk factor for less Tegner improvement. In KSSc, Group A improved by 43 points (95% CI 40.82/46.14), while Group B showed a greater increase of 53 points (95% CI 49.74/57.80). Adjusted for confounders, those >80 showed significantly higher KSSc improvement (12.8 points). For KSSf, Group A improved by 33.91 points (95% CI 31.07/36.75), and Group B by 15.57 points (95% CI 11.78/19.35). Adjusted for confounders, patients >80 had less improvement than those <80 (19 points). CONCLUSIONS: Patients who underwent TKR experienced improvements in physical and functional activity parameters. While these improvements were seen in the entire population, they were most notable in patients younger than 80 years.

9.
Knee ; 50: 18-26, 2024 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-39098086

RESUMO

BACKGROUND: In total knee arthroplasty (TKA), cementless fixation is initially weaker than cement fixation. This study aimed to examine whether filling the tibial peg holes with bone improves initial fixation strength in cementless TKA. METHODS: This prospective, comparative study examined 88 joints in 66 patients randomized to the bone filling (48 joints) or conventional group (no bone filling; 40 joints). All patients underwent TKA with the NexGen® trabecular metal modular tibial component. In the bone filling group, resected cancellous bone was filled into the peg holes before insertion of the tibial component. We performed clinical and plain radiographic evaluations after the operation and measured bone mineral density (BMD) at five sites below the component at 1, 3, 6, and 12 months postoperatively. RESULTS: Operative time and clinical evaluations were not significantly different. Plain radiography showed significant longitudinal thickening of the trabecula below the peg (P<0.05) and decreased occurrence of reactive lines (P=0.07) in the bone filling group compared with the conventional group. BMD was significantly higher in the bone filling group in the medial region below the peg at 1, 3, and 6 months and in the central region at 1 and 3 months (all P<0.05). CONCLUSIONS: When using the NexGen trabecular metal modular tibial component, concurrent peg hole bone filling increases the initial component fixation strength. Possible effects on long-term stabilization warrant further study.

10.
J Exp Orthop ; 11(3): e12076, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38957226

RESUMO

Purpose: Arthroplasty registers can provide feedback information on the results of arthroplasties performed by a certain institution or surgeon. The use of real-world data to achieve real-world evidence can help evaluate the performance of the implants used and help counsel our patients. The main objective of our study was to determine the survivorship of the total knee implant we are currently using. Methods: A retrospective cohort study of patients who received a total knee arthroplasty from January 2009 to December 2020 in our hospital was conducted, using data from the Catalan arthroplasty registry and the Catalan health service database. Demographic and surgical data were analysed using the Kaplan-Meier method, log-rank test and Cox proportional hazards models with the R Project software (p < 0.05). Results: A total of 1336 total knee arthroplasties were included in the study, of which 992 were women. The causes for revision included aseptic loosening (17), infection (29), instability (13), patellar implantation (13), arthrofibrosis (5) and quadriceps tendon rupture (1).The cumulative risk for revision at 5 years using the Kaplan-Meier method was 6.0% and at 10 years 6.5%. Considering gender, this risk was 7.0% and 7.5% at 5 and 10 years, respectively, in women and 3.3% in men, both at 5 and 10 years (p = 0.009). A higher risk for revision in women was seen, which is considered statistically significant (p = 0.012). Conclusion: Our survivorship results are comparable to those published in the literature, but with a higher revision risk in women that is only statistically significant for the whole group of reoperations and for patellar implantation, but not for the rest of the diagnoses. Level of Evidence: Level IV.

11.
Cureus ; 16(6): e61546, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38962584

RESUMO

Introduction Optimal repair of the joint line (JL) in total knee arthroplasty (TKA) is critical for knee joint motion reconstruction and ligament balance. Identification of JL may be difficult, particularly in revision or primary cases of severe femoral condylar bone loss. We aimed to define the relationship between the epicondyles and the articular surface (AS) of the femur using computed tomography-based three-dimensional digital templating software. Methods The study included 127 knees with osteoarthritis of the knee below grade 2 on the Kellgren-Lawrence index. A perpendicular line was drawn from the medial and lateral femoral epicondylar processes to the most distal point of the AS, and the distance was measured in the axial and coronal planes. Femoral width was measured as the distance between the medial and lateral epicondyles. All distances described above were converted to a ratio by division with femoral width. Results On the axial plane, the distance from epicondyles to the posterior ASs was 29.4 ± 2.2 mm medially and 21.3 ± 2.1 mm laterally. The width of the distal femur was 75.2 ± 4.2 mm. On the coronal plane, the distances from epicondyles to the distal ASs were 25.2 ± 2.9 mm on the medial side and 21.3 ± 2.5 mm on the lateral side. The ratio of the distance from epicondyles to the distal and posterior ASs divided by the width of the femur was 0.39 ± 0.02, 0.28 ± 0.03, 0.34 ± 0.03, and 0.28 ± 0.03. Conclusions The distance from the epicondyles to the distal and posterior JLs correlates with the distal femur width. These findings may be useful in determining an appropriate JL.

12.
J Perianesth Nurs ; 2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-38980235

RESUMO

PURPOSE: Preoperative anxiety is considered a common part of the surgerical experience and can be associated with serious postoperative side effects. This study aims to determine the relationship between preoperative anxiety level and postoperative pain outcomes in patients undergoing total hip replacement (THR) and total knee replacement (TKR). DESIGN: The study used a cross-sectional and correlational research method. METHODS: The study was conducted with a total of 104 participants, who underwent 17 THR and 87 TKR, at the Orthopedic Clinic of a state hospital in southern Turkey between June 2021 and June 2022. The State-Trait Anxiety Inventory (STAI) was used to determine preoperative anxiety level, and the Visual Analog Scale (VAS) and the Revised American Pain Society Patient Outcome Questionnaire (APS-POQ-R) were used to assess postoperative pain level. FINDINGS: The mean preoperative STAI-I and STAI-II scores of the participants who underwent THR and TKR were 53.95 ± 10.51 and 44.20 ± 10.55, respectively. There was a moderate positive correlation between STAI-I scores and VAS pain scores at preoperative and postoperative 6th, 12th, 24th, and 36th hours. There was a moderate positive correlation between STAI-I scores and affective subdimension scores, a moderate positive correlation with pain severity and sleep interference and activity interference, and a weak positive correlation between STAI-II scores and pain severity and sleep interference, activity interference and affective. The factors independently affecting the 6th-hour VAS pain score were determined as male gender, THR procedure, and increasing STAI score. CONCLUSIONS: We found that high preoperative state anxiety was associated with early postoperative pain outcomes. State anxiety was associated with pain in the 6th postoperative hour. Considering the multidimensional nature of anxiety, further research is recommended to understand the anxiety domain in surgical patients.

13.
Int Orthop ; 2024 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-38997513

RESUMO

PURPOSE: Resecting the posterior cruciate ligament (PCL) increases posterior laxity and increases the flexion gap more than the extension gap in the native (i.e. healthy) knee. These two effects could lead to significant anterior displacement of the medial femoral condyle in kneeling following total knee arthroplasty even when using a tibial insert with a high degree of medial conformity. Using an insert with ball-in-socket medial conformity and a flat lateral articular surface, the primary purpose was to determine whether the medial femoral condyle remained stable with and without PCL retention during kneeling. METHODS: Two groups of patients were studied, one with PCL retention (22 patients) and the other with PCL resection (25 patients), while kneeling at 90º flexion. Following 3D model-to-2D image registration, A-P displacements of both femoral condyles were determined relative to the dwell point of the medial socket. RESULTS: With PCL resection versus PCL retention, the medial femoral condyle was 5.1 ± 3.7 mm versus 0.8 ± 2.1 mm anterior of the dwell point (p < 0.0001). Patient-reported function scores were comparable (p ≥ 0.1610) despite a significantly shorter follow-up of 7.8 ± 0.9 months with PCL retention than 19.6 ± 4.9 months with PCL resection (p < 0.0001). Range of motion was 126 ± 8° versus 122 ± 6° with and without PCL retention, respectively (p = 0.057). CONCLUSION: Surgeons that use a highly conforming tibial insert design can stabilize the medial femoral condyle during kneeling by retaining the PCL. In patients with PCL resection, the 9 mm high anterior lip of the insert with ball-in-socket medial conformity was insufficient to prevent significant anterior displacement of the medial femoral condyle when weight-bearing on the anterior tibia.

14.
Trials ; 25(1): 468, 2024 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-38987786

RESUMO

BACKGROUND: With the increasing number of joint replacement surgeries, periprosthetic joint infection (PJI) has become a significant concern in orthopedic practice, making research on PJI prevention paramount. Therefore, the study will aim to compare the effect of combined usage of povidone-iodine and topical vancomycin powder to the use of povidone-iodine alone on the PJI incidence rate in patients undergoing primary total hip (THA) and total knee arthroplasty (TKA). METHODS: The prospective randomized clinical trial will be conducted in two independent voivodeship hospitals with extensive experience in lower limb arthroplasties. The studied material will comprise 840 patients referred to hospitals for primary THA or TKA. The patients will be randomly allocated to two equal groups, receiving two different interventions during joint replacement. In group I, povidone-iodine irrigation and consecutively topical vancomycin powder will be used before wound closure. In group II, only povidone-iodine lavage irrigation will be used before wound closure. The primary outcome will be the incidence rate of PJI based on the number of patients with PJI occurrence within 90 days after arthroplasty. The occurrence will be determined using a combined approach, including reviewing hospital records for readmissions and follow-up phone interviews with patients. The infection will be diagnosed based on Musculoskeletal Infection Society criteria. The chi-square test will be used to compare the infection rates between the two studied groups. Risk and odds ratios for the between-groups comparison purposes will also be estimated. Medical cost analysis will also be performed. DISCUSSION: A randomized clinical trial comparing the effect of combined usage of povidone-iodine irrigation and vancomycin powder to the use of povidone-iodine irrigation alone in preventing PJIs after primary arthroplasty is crucial to advancing knowledge in orthopedic surgery, improving patient outcomes, and guiding evidence-based clinical practices. TRIAL REGISTRATION: ClinicalTrials.gov NCT05972603 . Registered on 2 August 2023.


Assuntos
Administração Tópica , Antibacterianos , Anti-Infecciosos Locais , Artroplastia de Quadril , Artroplastia do Joelho , Povidona-Iodo , Infecções Relacionadas à Prótese , Ensaios Clínicos Controlados Aleatórios como Assunto , Irrigação Terapêutica , Vancomicina , Humanos , Antibacterianos/administração & dosagem , Antibacterianos/efeitos adversos , Anti-Infecciosos Locais/administração & dosagem , Artroplastia de Quadril/efeitos adversos , Artroplastia do Joelho/efeitos adversos , Incidência , Estudos Multicêntricos como Assunto , Povidona-Iodo/administração & dosagem , Pós , Estudos Prospectivos , Infecções Relacionadas à Prótese/prevenção & controle , Infecções Relacionadas à Prótese/epidemiologia , Irrigação Terapêutica/métodos , Resultado do Tratamento , Vancomicina/administração & dosagem
15.
Artigo em Inglês | MEDLINE | ID: mdl-39031337

RESUMO

BACKGROUND: Total knee arthroplasty (TKA) is a widely performed surgical procedure aimed at alleviating pain and restoring functionality in individuals suffering from knee osteoarthritis. Despite substantial benefits of TKA, patients are exposed to potential risks, including the occurrence of falls during their recovery period following discharge from the hospital. OBJECTIVE: This integrative review endeavors to comprehensively investigate the existing body of literature to identify and assess the diverse factors that contribute to occurrence of post-discharge falls among TKA patients. Through the synthesis of available research, this study seeks to offer valuable insights that can guide clinical practices and interventions designed to mitigate the incidence of post-TKA falls, ultimately enhancing patient outcomes and quality of healthcare. METHODS: An integrative review was conducted and databases were searched including Pubmed, PEDro, Cochrane, and SPORTDiscus from 2000 to 2024. A thorough search was performed to retrieve articles missed through databases as well as unpublished grey literature. Methodological quality assessment was performed using Newcastle-Ottawa Scale for Case Control and Cohort studies and AXIS tool for cross-sectional study. RESULTS: Eleven articles finally met the inclusion criteria and were included in the review based on eligibility. There were 8 cohort studies (7 prospective cohorts, 1 retrospective cohort), 2 case control studies, and 1 cross-sectional study. The prospective cohort studies included in the review collected data in real-time as events occurred, making them particularly relevant for studying post-TKA falls. CONCLUSION: Patients who underwent TKA are at risk of post-discharge falls. Several key risk factors have been identified, including advancing age, female gender, reduced proprioception, psychiatric disorders, living alone, and knee pain in the operated knee. It is important to recognize that the significance of these risk factors can vary depending on individual circumstances and contexts.

16.
Artigo em Inglês | MEDLINE | ID: mdl-39031664

RESUMO

PURPOSE: The objective of this study was to describe a planning method for medial unicompartmental knee arthroplasty (UKA) implantation using preoperative stress radiographs to measure the thickness of tibial and femoral bone resections and to validate this method with data from an image-based robotic surgery system. Having such method for preoperative planning would be of interest for surgeons performing UKA in order to anticipate optimal bone resection on both tibia and femoral sides. METHODS: A new planning method for medial UKA based on valgus stress knee radiographs validated it with an image-based robotic surgery system (Restoris MCK, MAKO®, Stryker Corporation) was proposed. This retrospective study involved radiographic measurements of 76 patients who underwent image-based robotic medial UKA between April 2022 and February 2023. Preoperative anteroposterior stress radiographs of the knee were used to simulate UKA implantation. The UKA technique was based on Cartier's angle and aimed at restoring the joint line. The total dimension measured was 14 mm (8 mm for minimal tibial component and polyethylene insert + 4 mm for femoral component + 2 mm for safety laxity). Bone resections were measured in the preoperative valgus stress radiographs and then against the intraoperative bone resection data provided by the robotic system. Inter- and intra-observer reliability was assessed using 25 measurements. RESULTS: The mean planned tibial resection measured in the radiographs was 4.3 ± 0.4 [2.9-5.8], while the mean robotic resection was 4.2 ± 0.5 [2.7-5.8] (mean difference = 0.15 mm, 95% confidence interval [CI] [-0.27 to 0.57]). There was a strong correlation between these two values (Pearson's rank R = 0.79, p < 0.001). Intra- and inter-observer reliability were also very strong (Pearson's rank R = 0.91, p < 0.001, and Pearson's rank R = 0.82, p < 0.001, respectively). The mean planned femoral bone resection measured in the radiographs was 2.7 ± 0.7 mm [1-4.5], while the mean robotic resection was 2.5 ± 0.9 [1-5] (mean difference = 0.21 mm, 95% CI [-0.66 to 1.08]). There was a strong correlation between these two values (Pearson's rank R = 0.82, p < 0.001). Intra- and inter-observer reliability were also strong (Pearson's rank R = 0.88, p < 0.001, and Pearson's rank R = 0.84, p < 0.001, respectively). CONCLUSION: This study describes and validates with robotic information a simple and reproducible preoperative planning method to determine femoral and tibial bone resection for medial UKA implantation using antero-posterior valgus stress knee radiographs, leaving a medial safety laxity of 2 mm. It represents a very valuable contribution to the understanding of UKA principles, which can serve to extend its indications and increase reproducibility of the surgical technique. LEVEL OF EVIDENCE: III. Retrospective cohort study.

17.
Soc Sci Med ; 355: 117112, 2024 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-39029443

RESUMO

Risk communication is a key legal and ethical component of shared decision-making. Decisions about total knee replacement, a common surgery, must contend with the fact that a minority of cases result in unintended outcomes, some of which have devastating effects. To understand how risks are communicated during decision-making, we audio-recorded and analysed 62 consultations between surgeons and patients. Various communication methods were evident, including listing risks without elaboration, discussing them in a conversational manner, abrogating discussion of risk, or using decision-tools. Discussion of risks was often brief in nature, and risk communication was sometimes curtailed or deferred by both patients and surgeons. Risks could also be observed to play a part in reinforcing policy norms of the doctor-patient relationship that highlighted patient responsibility. Nevertheless, patients and surgeons in the observed consultations appeared more interested in developing trusting relationships than in discussing risks. Because patients had sometimes experienced considerable deterioration in their knee function before their consultation, were in pain and struggled with mobility, the realities of clinical practice clashed with the policy norms of choice and patient responsibility. Rather, decisions could appear coerced by the disease process rather than being clear-cut examples of self-determination. While policy norms putatively use risk disclosure to frame communication between patients and clinicians as a transaction between customer and technician, the lack of conformity to these norms in the consultations may indicate resistance to this framing. A greater emphasis on determining positive roles for trust and care would help policy to present a nuanced understanding of decision-making. Risk communication could be seen as a factor in the formation of trusting relationships, improving its role in decision-making processes while recognising its inherent tensions with practice.

18.
Front Bioeng Biotechnol ; 12: 1426388, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39015137

RESUMO

Introduction: The formation of bacterial biofilms on knee arthroplasty implants can have catastrophic consequences. The aim of this study was to analyze the effectiveness of the bioelectric effect in the elimination of bacterial biofilms on cultivated knee arthroplasty implants. Methods: A novel device was designed to deliver a bioelectric effect on the surface of knee arthroplasty implants. 4-femoral prosthetic implants were cultivated with a staphylococcus aureus inoculum for 15 days. The components were divided into four different groups: A (not treated), B (normal saline 20-minutes), C (bioelectric effect 10-minutes), D (bioelectric effect 20-minutes). The implants were sonicated, and the detached colonies were quantified as the number of colony-forming unit (CFUs). The implants were sterilised and the process was repeated in a standardized manner four more times, to obtain a total of five samples per group. Results: The number of the CFUs after a 10-minute exposure to the bioelectric effect was of 208.2 ± 240.4, compared with 6,041.6 ± 2010.7 CFUs in group A, representing a decrease of 96.5% ± 4.3 (p = 0.004). And a diminution of 91.8% ± 7.9 compared with 2,051.0 ± 1,364.0 CFUs in group B (p = 0.109). The number of bacterial colonies after a 20-minute exposure to the bioelectric effect was 70 ± 126.7 CFUs, representing a decrease of 98.9% ± 1.9 (p = 0.000) compared with group A. And a decrease of 97.8% ± 3.0 (p = 0.019) compared with group B. Conclusions: The bioelectric effect was effective in the elimination of bacterial biofilm from knee arthroplasty implants. This method could be used in the future as part of conventional surgical procedures.

19.
Orthop Rev (Pavia) ; 16: 120308, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38957745

RESUMO

The diagnosis of periprosthetic joint infections (PJI) presents a formidable challenge to orthopaedic surgeons due to its complex and diverse manifestations. Accurate diagnosis is of utmost importance, as even mild pain following joint replacement surgery may indicate PJI in the absence of a definitive gold standard diagnostic test. Numerous diagnostic modalities have been suggested in the literature, and international societies have continually updated diagnostic criteria for this debilitating complication. This review article aims to comprehensively examine the latest evidence-based approaches for diagnosing PJI. Through a thorough analysis of current literature, we explore promising diagnostic strategies that have demonstrated effectiveness in identifying PJI. These strategies encompass the utilization of laboratory markers, such as erythrocyte sedimentation rate (ESR) and C-reactive protein (CRP), alongside imaging techniques such as magnetic resonance imaging (MRI) and leukocyte scintigraphy. Additionally, we highlight the importance of synovial fluid analysis, including the potential role of alpha-defensin as a biomarker, and examine evolving international diagnostic criteria to standardize and improve diagnostic accuracy.

20.
Knee ; 49: 147-157, 2024 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-38964260

RESUMO

BACKGROUND: Day surgery for unicompartmental knee replacement (UKR) could potentially reduce hospital costs. We aimed to measure the impact of introducing a day surgery UKR pathway on mean length of stay (LOS) and costs for the UK NHS, compared to an accelerated inpatient pathway. Secondly, the study aimed to compare the magnitude of costs using three costing approaches: top-down costing; simple micro-costing; and real-world costing. METHODS: We conducted an observational, before-and-after study of 2,111 UKR patients at one NHS hospital: 1,094 patients followed the day surgery pathway between September 2017 and February 2020; and 1,017 patients followed the accelerated inpatient pathway between September 2013 and February 2016. Top-down costs were estimated using Average NHS Costs. Simple micro-costing used the cost per bed-day. Real-world costs for this centre were estimated by costing actual changes in staffing levels. RESULTS: 532 (48.5%) patients in the day surgery pathway were discharged on the day of surgery compared with 36 (3.5%) patients in the accelerated inpatient pathway. The day surgery pathway reduced the mean LOS by 2.2 (95% CI: 1.81, 2.53) nights and was associated with an 18% decrease in Average NHS Costs (p < 0.001). Mean savings were £1,429 per patient with the Average NHS Costs approach, £905 per patient with the micro-costing approach, and £577 per patient with the "real-world" costing approach. Overall, moving NHS UKR surgeries to a day surgery pathway could save the NHS £8,659,740 per year. CONCLUSION: Day surgery for UKR could produce substantial cost savings for hospitals and the NHS.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA