Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.370
Filtrar
1.
Sci Rep ; 14(1): 10360, 2024 05 06.
Artigo em Inglês | MEDLINE | ID: mdl-38710733

RESUMO

An experimental design and response surface methodologies using Plackett-Burman and Box-Behnken designs were applied for selecting and optimizing the most appropriate parameters which significantly affect the separation and quantitative estimation of five skeletal muscle relaxants and four analgesic drugs (baclofen, methocarbamol, dantrolene sodium, orphenadrine citrate, cyclobenzaprine hydrochloride, ketoprofen, etoricoxib, ibuprofen, and mefenamic acid) with a relatively short duration of analysis in a single run. For the separation of the nine drugs, an INERTSIL ODS-V3-5 µm C18 column (250 × 4.6 mm I.D.) was used with the optimum mobile phase conditions (45.15 mM ammonium acetate buffer pH 5.56 adjusted with acetic acid, acetonitrile, and methanol in a ratio of 30.5:29.5:40, v/v/v with a flow rate of 1.5 mL/min) and UV-detection at 220 nm. The optimized method was successfully subjected to the validation steps as described in ICH guidelines for linearity, precision, accuracy, robustness, and sensitivity. The optimized and validated method was effectively applied to determine the content of the studied drugs in their pharmaceutical preparations and to expand its applicability to the counterfeit estimation of etoricoxib in different brands of tablet dosage forms.


Assuntos
Analgésicos , Cromatografia Líquida de Alta Pressão/métodos , Analgésicos/análise , Fármacos Neuromusculares/análise , Reprodutibilidade dos Testes , Cromatografia de Fase Reversa/métodos , Projetos de Pesquisa
2.
Chirality ; 36(5): e23672, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38693625

RESUMO

Hydroxychloroquine (HCQ), 2-([4-([7-Chloro-4-quinolyl]amino)pentyl]ethylamino)ethanol, exhibited significant biological activity, while its side effects cannot be overlooked. The RP-HPLC enantio-separation was investigated for cost-effective and convenient optical purity analysis of HCQ. The thermodynamic resolution of Rac-HCQ, driven by enthalpy and entropy, was achieved on the C18 column using Carboxymethyl-ß-cyclodextrin (CM-ß-CD) as the chiral mobile phase agent (CMPA). The effects of CCM-ß-CD, pH, and triethylamine (TEA) V% on the enantio-separation process were explored. Under the optimum conditions at 24°C, the retention times for the two enantiomers were t R 1 = 29.39 min $$ {t}_{R1}=29.39\ \min $$ and t R 2 = 32.42 min $$ {t}_{R2}=32.42\ \min $$ , resulting in R s = 1.87 $$ {R}_s=1.87 $$ . The resolution via diastereomeric salt formation of Rac-HCQ was developed to obtain the active pharmaceutical ingredient of single enantiomer S-HCQ. Di-p-Anisoyl-L-Tartaric Acid (L-DATA) was proved effective as the resolution agent for Rac-HCQ. Surprisingly, it was found that refluxing time was a key fact affecting the resolution efficiency, which meant the kinetic dominate during the process of the resolution. Four factors-solvent volume, refluxing time, filtration temperature, and molar ratio-were optimized using the single-factor method and the response surface method. Two cubic models were established, and the reliability was subsequently verified. Under the optimal conditions, the less soluble salt of 2L-DATA:S-HCQ was obtained with a yield of 96.9% and optical purity of 63.0%. The optical purity of this less soluble salt increases to 99.0% with a yield of 74.2% after three rounds recrystallization.


Assuntos
Hidroxicloroquina , Hidroxicloroquina/química , Estereoisomerismo , Cromatografia Líquida de Alta Pressão/métodos , Concentração de Íons de Hidrogênio , beta-Ciclodextrinas/química , Cromatografia de Fase Reversa/métodos , Etilaminas/química , Termodinâmica , Sais/química
3.
Methods Mol Biol ; 2788: 67-79, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38656509

RESUMO

Derivatization of monosaccharides with 1-phenyl-3-methyl-5-pyrazolone (PMP) introduces two chromophores per sugar molecule. Their separation on a superficially porous C18 reverse-phase column, using common liquid chromatography equipment, results in short analysis times (under 20 min) and high sensitivity (limit of quantitation 1 nmol). This method allows for complex monosaccharide mixtures to be separated and quantified using a reasonably simple and safe derivatization procedure.


Assuntos
Cromatografia de Fase Reversa , Monossacarídeos , Cromatografia de Fase Reversa/métodos , Monossacarídeos/química , Monossacarídeos/análise , Cromatografia Líquida de Alta Pressão/métodos , Espectrofotometria Ultravioleta/métodos , Edaravone/química , Antipirina/análogos & derivados , Antipirina/química
4.
J Chromatogr A ; 1722: 464843, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38574599

RESUMO

Reversed-phase high performance liquid chromatography (RP-HPLC) is the most widely used chromatographic method. In addition to hydrophobic interactions, additional interactions such as electrostatic interactions may participate in the retention behaviour of an analyte. This makes it possible to use RP-HPLC for many types of analyte. We describe a simple method for separating inorganic anions on a C18 column, in which retention of inorganic anions is almost entirely due to electrostatic interactions. This leads to rapid separations as well as higher theoretical plate numbers. We used 2 mM phosphoric acid containing a low concentration of disodium molybdate as the mobile phase, which allows UV detection of non-UV-absorbing anions. With this method, we determined eight inorganic anions including several non-UV-absorbing anions photometrically at 220 nm. The detection limits of the examined eight inorganic anions calculated at a signal-to-noise ratio of 3 were between 0.3 and 10 µM. The detector response was linear over three orders of magnitude of inorganic anion concentration. The proposed RP-HPLC/UV method was successfully applied to determine inorganic anions in some water samples.


Assuntos
Ânions , Cromatografia de Fase Reversa , Molibdênio , Ácidos Fosfóricos , Ânions/química , Molibdênio/química , Ácidos Fosfóricos/química , Cromatografia de Fase Reversa/métodos , Cromatografia Líquida de Alta Pressão/métodos , Limite de Detecção
5.
J Chromatogr A ; 1722: 464856, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38579610

RESUMO

Complex mixture analysis requires high-efficiency chromatography columns. Although reversed phase liquid chromatography (RPLC) is the dominant approach for such mixtures, hydrophilic interaction liquid chromatography (HILIC) is an important complement to RPLC by enabling the separation of polar compounds. Chromatography theory predicts that small particles and long columns will yield high efficiency; however, little work has been done to prepare HILIC columns longer than 25 cm packed with sub-2 µm particles. In this work, we tested the slurry packing of 75 cm long HILIC columns with 1.7 µm bridged-ethyl-hybrid amide HILIC particles at 2,100 bar (30,000 PSI). Acetonitrile, methanol, acetone, and water were tested as slurry solvents, with acetonitrile providing the best columns. Slurry concentrations of 50-200 mg/mL were assessed, and while 50-150 mg/mL provided comparable results, the 150 mg/mL columns provided the shortest packing times (9 min). Columns prepared using 150 mg/mL slurries in acetonitrile yielded a reduced minimum plate height (hmin) of 3.3 and an efficiency of 120,000 theoretical plates for acenaphthene, an unretained solute. Para-toluenesulfonic acid produced the lowest hmin of 1.9 and the highest efficiency of 210,000 theoretical plates. These results identify conditions for producing high-efficiency HILIC columns with potential applications to complex mixture analysis.


Assuntos
Acetonitrilas , Benzenossulfonatos , Interações Hidrofóbicas e Hidrofílicas , Acetonitrilas/química , Cromatografia Líquida/métodos , Cromatografia de Fase Reversa/métodos , Cromatografia de Fase Reversa/instrumentação , Metanol/química , Solventes/química , Acetona/química , Tamanho da Partícula , Pressão , Água/química
6.
J Chromatogr A ; 1722: 464828, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38581973

RESUMO

The linkages of disulfide bond (DSB) play important roles in protein stability and activity. Mass spectrometry-based (MS-based) techniques become accepted tools for DSB analysis in the recent decade. In the bottom-up approach, after enzyme digestion, the neighbouring amino acids of cysteines have great impacts on the physicochemical properties of resulting disulfide bond peptides, determining their retention behaviour on liquid chromatography (LC) and their MS ionization efficiency. In this study, the addition of supercharging reagent in LC mobile phase was used to examine the impact of supercharging reagent on the charge states of disulfide-bond peptides. The results showed that 0.1 % m-nitrobenzyl alcohol (m-NBA) in LC mobile phase increased the sensitivity and charge states of DSB peptides from our model protein, equine Interleukin-5 (eIL5), as well as the resolution of reversed-phase chromatography. Notably, also the sensitivity of C-terminal peptide with His-tag significantly improved. Our findings highlight the effectiveness of employing m-NBA as a supercharging reagent when investigating disulfide-linked peptides and the C-terminal peptide with a His-tag through nano-liquid chromatography mass spectrometry.


Assuntos
Álcoois Benzílicos , Dissulfetos , Peptídeos , Dissulfetos/química , Álcoois Benzílicos/química , Álcoois Benzílicos/isolamento & purificação , Peptídeos/química , Peptídeos/isolamento & purificação , Animais , Cavalos , Histidina/química , Cromatografia Líquida/métodos , Cromatografia de Fase Reversa/métodos , Cromatografia Líquida de Alta Pressão/métodos
7.
J Chromatogr A ; 1722: 464871, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38593520

RESUMO

Mixed-mode reversed-phase/anion-exchange chromatography (RP/AEX) is an effective method for the chromatographic analysis of acidic drugs because it combines reversed-phase chromatography (RP) with anion-exchange chromatography (AEX). However, the result repeatability for the RP/AEX analysis of acidic drugs is frequently compromised by the detrimental effects of residual silanol groups in an RP/AEX stationary phase on peak separation and analyte retention. In this study, an RP/weak-AEX stationary phase with amino anion-exchange groups, Sil-AA, was prepared. Subsequently, an RP/strong-AEX stationary phase, Sil-PBQA, was prepared by replacing the amino groups in Sil-AA with a benzene ring and a benzyl-containing quaternary ammonium salt. The chromatographic behaviors of Sil-PBQA and Sil-AA were compared, and the effect of residual silanol groups on the chromatographic behavior of an RP/AEX stationary phase was evaluated. Residual silanol groups not only caused additional electrostatic interactions for acidic analytes, but also competed with the analytes for the anion-exchange sites in an RP/AEX stationary phase. The effects of different salt-containing mobile-phase systems on the analyte-retention behavior of Sil-PBQA were investigated to develop a method that enhanced the repeatability of the RP/AEX acidic-analyte-analysis results obtained using Sil-PBQA and facilitated the separation of nonsteroidal anti-inflammatory drugs on Sil-PBQA. The ideas presented in this paper can improve the separation of peaks and repeatability of results in the RP/AEX analysis of acidic drugs.


Assuntos
Anti-Inflamatórios não Esteroides , Cromatografia de Fase Reversa , Cromatografia de Fase Reversa/métodos , Cromatografia por Troca Iônica/métodos , Anti-Inflamatórios não Esteroides/análise , Anti-Inflamatórios não Esteroides/química , Ânions/química , Ânions/análise , Reprodutibilidade dos Testes , Silanos/química , Concentração de Íons de Hidrogênio , Cromatografia Líquida de Alta Pressão/métodos
8.
J Chromatogr A ; 1722: 464889, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38598894

RESUMO

In this paper, three imidazole- and C18- bifunctional silica stationary phases (Sil-Im-C18) were prepared by adjusting introduction interval of octadecyltrichlorosilane (ODS) and 3-imidazol-1-ylpropyl(trimethoxy)silane (TMPImS), which can be used for reversed-phase liquid chromatography (RPLC) and ion exchange chromatography (IEC) with adjustable performance. The successful preparation of Sil-Im-C18 were confirmed by the characterizations of elemental analysis, infrared spectroscopy (FTIR) and contact angle (CA). Chromatographic performance of Sil-Im-C18 were evaluated by the separation of Tanaka test mixture, alkylbenzenes, linear PAHs and a set of analytes with different properties (uracil, phenol, 1,2-dinitrobenzene and naphthalene), and compared with commonly used C18 column. It was found that the chromatographic performance of Sil-Im-C18 changed significantly with the difference in bonding amount of imidazole and C18. Sil-Im-C18 demonstrated the excellent separation performance towards polycyclic aromatic hydrocarbons (PAHs), phenylesters, phenylamines, phenols and inorganic anions, and notably, nucleobases and nucleosides can be separated using pure water as mobile phases. The van Deemter plot showed that the column efficiency of Sil-Im-C18-3 was 64,933 plate·m-1 for naphthalene, indicated that Sil-Im-C18 was reasonably chromatographic columns. The RSD values of retention time were 0.22 %-0.61 % for 10 needles alkylbenzenes injected continuously at 50 °C to investigate thermal stability and repeatability, all the fluctuations of k of naphthalene were less than 2.3 % for Sil-Im-C18-1 during flushing 24 h with the mobile phase at different pH values (pH = 3 and 8), the retention time of alkylbenzenes were almost same for Sil-Im-C18-1 at different time, the RSD values of retention time of alkylbenzenes were 0.45 %-2.28 % for two batches Sil-Im-C18-1, revealing the excellent repeatability, thermal stability, durability and reproducibility of Sil-Im-C18, and implying a commercial prospect.


Assuntos
Cromatografia de Fase Reversa , Imidazóis , Hidrocarbonetos Policíclicos Aromáticos , Dióxido de Silício , Imidazóis/química , Dióxido de Silício/química , Cromatografia de Fase Reversa/métodos , Hidrocarbonetos Policíclicos Aromáticos/análise , Hidrocarbonetos Policíclicos Aromáticos/isolamento & purificação , Hidrocarbonetos Policíclicos Aromáticos/química , Silanos/química , Cromatografia por Troca Iônica/métodos
9.
Anal Chem ; 96(15): 5860-5868, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38567987

RESUMO

Supramolecular hydrogels formed through polymer-nanoparticle interactions are promising biocompatible materials for translational medicines. This class of hydrogels exhibits shear-thinning behavior and rapid recovery of mechanical properties, providing desirable attributes for formulating sprayable and injectable therapeutics. Characterization of hydrogel composition and loading of encapsulated drugs is critical to achieving the desired rheological behavior as well as tunable in vitro and in vivo payload release kinetics. However, quantitation of hydrogel composition is challenging due to material complexity, heterogeneity, high molecular weight, and the lack of chromophores. Here, we present a label-free approach to simultaneously determine hydrogel polymeric components and encapsulated payloads by coupling a reversed phase liquid chromatographic method with a charged aerosol detector (RPLC-CAD). The hydrogel studied consists of modified hydroxypropylmethylcellulose, self-assembled PEG-b-PLA nanoparticles, and a therapeutic compound, bimatoprost. The three components were resolved and quantitated using the RPLC-CAD method with a C4 stationary phase. The method demonstrated robust performance, applicability to alternative cargos (i.e., proteins) and was suitable for composition analysis as well as for evaluating in vitro release of cargos from the hydrogel. Moreover, this method can be used to monitor polymer degradation and material stability, which can be further elucidated by coupling the RPLC method with (1) a multi-angle light scattering detector (RPLC-MALS) or (2) high resolution mass spectrometry (RPLC-MS) and a Fourier-transform based deconvolution algorithm. We envision that this analytical strategy could be generalized to characterize critical quality attributes of other classes of supramolecular hydrogels, establish structure-property relationships, and provide rational design guidance in hydrogel drug product development.


Assuntos
Hidrogéis , Nanopartículas , Hidrogéis/química , Cromatografia de Fase Reversa/métodos , Polietilenoglicóis/química , Aerossóis
10.
Artigo em Inglês | MEDLINE | ID: mdl-38640792

RESUMO

The aim of this study was to improve analysis of nonpolar lipidomics sample extracts using reversed phase (RP) chromatography. A 4/3/3 (v/v/v) mixture of methanol/methyl tert-butyl ether/chloroform (MeOH/MTBE/CHCl3, MMC) was chosen for sample extraction solvent based on its proven extraction capability for several lipid classes. To avoid carry over, loss of analytes and peak distortion the loops and all capillaries of the presented LC system were flushed and filled up with methanol until the analytical column. The choice of methanol was due to its weak elution strength and being infinitely miscible with MMC and several other nonpolar solvents. This allowed injection of a 100 µl sample that was 20 µl nonpolar extraction solvent diluted fivefold with methanol. All lipids of 25 lipid classes were transferred quantitatively to the column head where the online dilution of methanol was carried out with aqueous eluent for focusing the lipid analytes. The weak elution strength of methanol prevented peak distortions. The consecutive reversed phase elution resulted in remarkably narrow peaks (full width at half maximum was 0.07-0.08 min typically) and enhanced sensitivity (limit of detection usually in sub nM region) because of increased sample injection volume and narrow peaks. Calibration and quality control samples made by diluting commercial lipid standards 200-50000 times confirmed the applicability of this approach both for targeted lipid quantification and for untargeted quantitative comparison of lipids from different sources.


Assuntos
Lipídeos , Lipídeos/química , Limite de Detecção , Animais , Metanol/química , Espectrometria de Massas/métodos , Lipidômica/métodos , Reprodutibilidade dos Testes , Cromatografia de Fase Reversa/métodos , Clorofórmio/química , Éteres Metílicos/química , Éteres Metílicos/análise , Cromatografia Líquida/métodos , Modelos Lineares , Espectrometria de Massa com Cromatografia Líquida
11.
J Chromatogr A ; 1721: 464818, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38564929

RESUMO

Comprehensive two-dimensional liquid chromatography (LCxLC) represents a valuable alternative to conventional single column, or one-dimensional, liquid chromatography (1D-LC) for resolving multiple components in a complex mixture in a short time. However, developing LCxLC methods with trial-and-error experiments is challenging and time-consuming, which is why the technique is not dominant despite its significant potential. This work presents a novel shortcut model to in-silico predicting retention time and peak width within an RPLCxRPLC separation system (i.e., LCxLC systems that use reversed-phase columns (RPLC) in both separation dimensions). Our computationally effective model uses the hydrophobic-subtraction model (HSM) to predict retention and considers limitations due to the sample volume, undersampling and the maximum pressure drop. The shortcut model is used in a two-step strategy for sample-dependent optimization of RPLCxRPLC separation systems. In the first step, the Kendall's correlation coefficient of all possible combinations of available columns is evaluated, and the best column pair is selected accordingly. In the second step, the optimal values of design variables, flow rate, pH and sample loop volume, are obtained via multi-objective stochastic optimization. The strategy is applied to method development for the separation of 8, 12 and 16 component mixtures. It is shown that the proposed strategy provides an easy way to accelerate method development for full-comprehensive 2D-LC systems as it does not require any experimental campaign and an entire optimization run can take less than two minutes.


Assuntos
Cromatografia de Fase Reversa , Cromatografia Líquida/métodos , Cromatografia de Fase Reversa/métodos
12.
Metabolomics ; 20(3): 49, 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38689195

RESUMO

INTRODUCTION: Untargeted metabolomics studies are expected to cover a wide range of compound classes with high chemical diversity and complexity. Thus, optimizing (pre-)analytical parameters such as the analytical liquid chromatography (LC) column is crucial and the selection of the column depends primarily on the study purpose. OBJECTIVES: The current investigation aimed to compare six different analytical columns. First, by comparing the chromatographic resolution of selected compounds. Second, on the outcome of an untargeted toxicometabolomics study using pooled human liver microsomes (pHLM), rat plasma, and rat urine as matrices. METHODS: Separation and analysis were performed using three different reversed-phase (Phenyl-Hexyl, BEH C18, and Gold C18), two hydrophilic interaction chromatography (HILIC) (ammonium-sulfonic acid and sulfobetaine), and one porous graphitic carbon (PGC) columns coupled to high-resolution mass spectrometry (HRMS). Their impact was evaluated based on the column performance and the size of feature count, amongst others. RESULTS: All three reversed-phase columns showed a similar performance, whereas the PGC column was superior to both HILIC columns at least for polar compounds. Comparing the size of feature count across all datasets, most features were detected using the Phenyl-Hexyl or sulfobetaine column. Considering the matrices, most significant features were detected in urine and pHLM after using the sulfobetaine and in plasma after using the ammonium-sulfonic acid column. CONCLUSION: The results underline that the outcome of this untargeted toxicometabolomic study LC-HRMS metabolomic study was highly influenced by the analytical column, with the Phenyl-Hexyl or sulfobetaine column being the most suitable. However, column selection may also depend on the investigated compounds as well as on the investigated matrix.


Assuntos
Interações Hidrofóbicas e Hidrofílicas , Metabolômica , Microssomos Hepáticos , Ratos , Animais , Humanos , Metabolômica/métodos , Microssomos Hepáticos/metabolismo , Cromatografia de Fase Reversa/métodos , Grafite/química , Plasma/química , Plasma/metabolismo , Cromatografia Líquida/métodos , Porosidade , Metaboloma
13.
J Pharm Biomed Anal ; 244: 116122, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-38547651

RESUMO

The objective of this current study is to establish a single method for potency and related proteins analysis of human insulin formulations using reverse-phase high performance liquid (RP-HPLC) chromatography technique which was validated and verified for the potency analysis in insulin formulations. Chromatographic separation was achieved using an octadecylsilane (C-18) stationary phase and a mobile phase composed of 55% (v/v) buffer (0.2 M sodium sulfate in water, {pH 2.3}) and 45% (v/v) acetonitrile. Detection was performed by UV detector at 214 nm with a flow rate of 1 ml/min and an injection volume of 20 µL, at 40°C. Currently there are separate methods available in Indian Pharmacopoeia for analysis of Potency and Related proteins in human insulin. We have validated a single method where quantitation of potency and related proteins can be performed in the same run. The method validation exhibited linearity over the concentration range of 0.08-4.5 mg/ml (r2=0.999) with limit of detection of 0.094 mg/ml The accuracy of the method was 99-102.8%. Thus, it is proposed that both potency and related proteins in insulin formulations can be precisely evaluated using a single run thus saving the time and cost for quality analysis of insulin preparations both at manufacturing and regulatory laboratories which in turn will increase the market availability of such standard quality insulin preparations for public health use.


Assuntos
Insulina , Cromatografia Líquida de Alta Pressão/métodos , Humanos , Insulina/análise , Reprodutibilidade dos Testes , Cromatografia de Fase Reversa/métodos , Limite de Detecção , Química Farmacêutica/métodos , Proteínas Recombinantes/análise , Hipoglicemiantes/análise , Hipoglicemiantes/química
14.
Artigo em Inglês | MEDLINE | ID: mdl-38513430

RESUMO

Developing a knob-into-hole asymmetric bispecific IgG1 monoclonal antibody (mAb) poses manufacturing challenges due to the expression of chain pairing variants, also called mispaired species, in the desired product. The incorrect pairing of light and heavy chains could result in heterogeneous mispaired species of homodimers, heterodimers, light chain swapping, and low molecular weight species (LMWS). Standard chromatography, capillary electrophoretic, or spectroscopic methods poorly resolve these from the main variants. Here, we report a highly sensitive reverse-phase polyphenyl ultra-high-performance liquid chromatography (RP-UHPLC) method to accurately measure mispaired species of Duet mAb format, an asymmetric IgG1 bispecific mAb, for both process development and quality control analytical tests. Coupled with electrospray ionization mass spectrometry (ESI-MS), it enabled direct online characterization of mispaired species. This single direct assay detected diverse mispaired IgG-like species and LMWS. The method resolved eight disulfide bonds dissociated LMWS and three mispaired LMWS. It also resolved three different types of IgG-like mispaired species, including two homodimers and one heterodimer. The characterization and quantification simultaneously enabled the cell line selection that produces a lesser heterogeneity and lower levels of mispaired species with the desired correctly paired product. The biological activity assessment of samples with increased levels of these species quantified by the method exhibited a linear decline in potency with increasing levels of mispaired species in the desired product. We also demonstrated the utility of the technique for testing in-process intermediate materials to determine and assess downstream purification process capability in removing diverse mispaired IgG-like species and LMWS to a certain level during the downstream purification process. Our investigation demonstrates that adopting this method was vital in developing asymmetric bispecific mAb from the initial stage of cell line development to manufacturing process development. Therefore, this tool could be used in the control strategy to monitor and control mispaired species during manufacturing, thus improving the quality control of the final product.


Assuntos
Anticorpos Biespecíficos , Espectrometria de Massas por Ionização por Electrospray , Imunoglobulina G/química , Cromatografia de Fase Reversa , Domínios Proteicos , Anticorpos Biespecíficos/química , Anticorpos Monoclonais/química
15.
Methods Mol Biol ; 2789: 67-73, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38506992

RESUMO

Ion concentration in liposomal drugs is important for drug stability and drug release profile. However, quantifying ion concentration in liposomal drugs is challenging due to the absence of chromophores or fluorophores of ions and the efficiency of their release from the liposome structure. To address these issues, a method based on reversed-phase high-performance liquid chromatography (RP-HPLC) coupled with a charged aerosol detector (CAD) has been developed to determine total, internal, and external ions in drug-loaded liposomal products. In this protocol, we focused on the quantitation of ammonium and sulfate ions in liposomal products, using generic PEGylated liposomal doxorubicin as an example. This method can be extended to calcium, acetate, and other ions in different liposomal formulations with slight modifications.


Assuntos
Doxorrubicina , Lipossomos , Lipossomos/química , Cromatografia Líquida de Alta Pressão/métodos , Doxorrubicina/química , Cromatografia de Fase Reversa , Íons , Aerossóis
16.
J Chromatogr A ; 1720: 464782, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38442498

RESUMO

Semicarbazide, as a derivative of urea, constitutes a great variety of functional molecules for different needs. Herein, novel stationary phases with an incorporated semicarbazide group were proposed. Using aliphatic (docosanoyl, C22) and aromatic (benzoyl, Bz) hydrazides, the semicarbazide-embedded ligands were synthesized before chemical modification of the silica gel, allowing for an accurate interpretation of the chromatographic properties of the corresponding packings. The new stationary phases were water-wettable, due to the presence of highly polar groups. In particular, Bz-semicarbazide (Bz-SCD) stationary phase was sufficiently hydrophilic to run in hydrophilic interaction (HILIC) mode, whilst the C22 (C22-SCD) equivalent, in spite of its reversed-phase nature, was markedly less hydrophobic than the referenced polar-embedded ones. The versatility of C22-SCD was demonstrated with a large selection of analytes, including geometric isomers and standard mixtures of polycyclic aromatic hydrocarbons, sulfonamides, sulfonylurea, substituted ureas, pyridines and carbamates, fat-soluble colorants, antifungal metabolites, angiotensin II receptor blockers and calcium channel blockers.


Assuntos
Cromatografia de Fase Reversa , Semicarbazidas , Dióxido de Silício , Cromatografia Líquida/métodos , Interações Hidrofóbicas e Hidrofílicas , Isomerismo , Dióxido de Silício/química
17.
J Chromatogr A ; 1720: 464793, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38484639

RESUMO

A generic performance comparison strategy has been developed to evaluate the impact of mobile-phase additives (ion-pairing agent / counter ion systems), distinct stationary phases on resulting resolving power, and MS detectability of oligonucleotides and their critical impurities in gradient IP-RPLC. Stationary-phase considerations included particle type (core-shell vs. fully porous particles), particle diameter, and pore size. Separations were carried out at 60°C to optimize mass transfer (C-term). The incorporation of an active column preheater mitigated thermal mismatches, leading to narrower peaks and overcoming peak splitting. Acetonitrile as organic modifier outweighed methanol in terms of peak-capacity generation and yielded a 30% lower back pressure. Performance screening experiments were conducted varying ion-pairing agents and counter ions, while adjusting gradient span achieved an equivalent effective retention window. Hexafluoromethylisopropanol yielded superior chromatographic resolution, whereas hexafluoroisopropanol yielded significantly higher MS detection sensitivity. The 1.7 µm core-shell particle columns with 100 Å pores provided maximum resolving power for small (15-35 mers) oligonucleotides. Sub-min analysis for 15-35 polyT ladders was achieved operating a 50 mm long column at the kinetic performance limits. High-resolution separations between a 21-mer modified RNA sequence oligonucleotides and its related (shortmer and phosphodiester) impurities and complementary strand were obtained using a coupled column set-up with a total length of 450 mm.


Assuntos
Espectrometria de Massa com Cromatografia Líquida , Oligonucleotídeos , Oligonucleotídeos/análise , Cromatografia de Fase Reversa/métodos , Espectrometria de Massas , Íons , Cromatografia Líquida de Alta Pressão/métodos
18.
J Chromatogr A ; 1720: 464795, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38490144

RESUMO

An accurate and efficient method was developed for the determination of azaspiracid shellfish toxins (azaspiracids-1, -2, and -3), neurotoxic shellfish toxins (brevetoxins-2 and -3), diarrhetic shellfish toxins (okadaic acid and dinophysistoxins-1 and -2), and the amnesic shellfish toxin (domoic acid) in mussels (Mytilus galloprovincialis). Lipophilic marine biotoxins (azaspiracids, brevetoxins, and okadaic acid group) were extracted with 0.5 % acetic acid in methanol under heating at 60°C to improve the extraction efficiency of okadaic acid group toxins and then cleaned up with a C18 solid-phase extraction cartridge. Domoic acid was extracted with 50 % aqueous methanol and then cleaned up with a graphitized carbon solid-phase extraction cartridge. Lipophilic marine biotoxins and domoic acid were quantified by reversed-phase liquid chromatography coupled to electrospray ionization tandem mass spectrometry. The developed method had insignificant matrix effects for the nine analytes and good recoveries in the range of 79.0 % to 97.6 % at three spiking levels for all analytes except brevetoxin-2 (43.8-49.8 %). The developed method was further validated by analyzing mussel tissue certified reference materials, and good agreement was observed between certified and determined values.


Assuntos
Bivalves , Ácido Caínico/análogos & derivados , Oxocinas , Toxinas de Poliéter , Compostos de Espiro , Espectrometria de Massas em Tandem , Animais , Ácido Okadáico/análise , Espectrometria de Massas em Tandem/métodos , Cromatografia de Fase Reversa , Metanol , Cromatografia Líquida/métodos , Frutos do Mar/análise , Toxinas Marinhas/análise , Bivalves/química , Extração em Fase Sólida
19.
Anal Methods ; 16(15): 2278-2285, 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38525815

RESUMO

Sterols are unsaponifiable lipids resulting from plant metabolism that exhibit interesting bioactive properties. Microalgae are a major source of specific phytosterols, most of which are still not fully characterized. The similarity in sterol structures and the existence of positional isomers make the separation of phytosterols challenging. A method was developed based on an offline two-dimensional (2D) system, reversed-phase liquid chromatography (RPLC)-supercritical fluid chromatography (SFC)/quadrupole time-of-flight (Q-ToF) mass spectrometry, for the identification of sterols in microalgae. Subsequent positive-mode MS/MS was used to confirm the identified phytosterols. The 2D chromatogram exhibited a pattern related to the positions of the double bonds, which were confirmed by standard injection, enabling structural elucidation. The analysis of the unsaponifiable fraction of two algae, namely Scenedesmus obliquus, a freshwater microalgae, and Padina pavonica, a marine macroalgae, highlighted the ability of the method to distinguish a large number of sterol isomers.


Assuntos
Cromatografia com Fluido Supercrítico , Microalgas , Fitosteróis , Cromatografia de Fase Reversa/métodos , Fitosteróis/análise , Espectrometria de Massas em Tandem/métodos , Cromatografia com Fluido Supercrítico/métodos , Esteróis , Plantas
20.
J Chromatogr A ; 1721: 464824, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38522405

RESUMO

Two-dimensional liquid chromatography (2D-LC), and in particular comprehensive two-dimensional liquid chromatography (LC×LC), offers increased peak capacity, resolution and selectivity compared to one-dimensional liquid chromatography. It is commonly accepted that the technique produces the best results when the separation mechanisms in the two dimensions are completely orthogonal; however, the use of similar separation mechanisms in both dimensions has been gaining popularity as it helps avoid difficulties related to mobile phase incompatibility and poor column efficiency. The remarkable advantages of using reversed phase in both dimensions (RPLC×RPLC) over other separation mechanisms made it a promising technique in the separation of complex samples. This review discusses some physical and practical considerations in method development for 2D-LC involving the use of RP in both dimensions. In addition, an extensive overview is presented of different applications that relied on RPLC×RPLC and 2D-LC with reversed phase column combinations to separate components of complex samples in different fields including food analysis, natural product analysis, environmental analysis, proteomics, lipidomics and metabolomics.


Assuntos
Cromatografia de Fase Reversa , Proteômica , Cromatografia Líquida/métodos , Cromatografia de Fase Reversa/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA