Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.872
Filtrar
Mais filtros








Intervalo de ano de publicação
1.
EuroIntervention ; 20(9): 591-601, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38726722

RESUMO

BACKGROUND: Little is known about the occurrence of subclinical new-onset atrial fibrillation (NOAF) after transcatheter aortic valve implantation (TAVI). AIMS: We aimed to evaluate the incidence, predictors, and clinical impact of subclinical NOAF after TAVI. METHODS: This was a multicentre study, including patients with aortic stenosis (AS) and no previous atrial fibrillation undergoing TAVI, with continuous ambulatory electrocardiogram (AECG) monitoring after TAVI. RESULTS: A total of 700 patients (79±8 years, 49% female, Society of Thoracic Surgeons score 2.9% [1.9-4.0]) undergoing transarterial TAVI were included (85% balloon-expandable valves). AECG was started 1 (0-1) day after TAVI (monitoring time: 14121314 days). NOAF was detected in 49 patients (7%), with a median duration of 185 (43-421) minutes (atrial fibrillation burden of 0.7% [0.3-2.8]). Anticoagulation was started in 25 NOAF patients (51%). No differences were found in baseline or procedural characteristics, except for a higher AS severity in the NOAF group (peak gradient: no NOAF: 71.9±23.5 mmHg vs NOAF: 85.2±23.8 mmHg; p=0.024; mean gradient: no NOAF: 44.4±14.7 mmHg vs NOAF: 53.8±16.8 mmHg; p=0.004). In the multivariable analysis, the baseline mean transaortic gradient was associated with a higher risk of NOAF after TAVI (odds ratio 1.04, 95% confidence interval: 1.01-1.06 for each mmHg; p=0.006). There were no differences between groups in all-cause mortality (no NOAF: 4.7% vs NOAF: 0%; p=0.122), stroke (no NOAF: 1.4% vs NOAF: 2.0%; p=0.723), or bleeding (no NOAF: 1.9% vs NOAF: 4.1%; p=0.288) from the 30-day to 1-year follow-up. CONCLUSIONS: NOAF detected with AECG occurred in 7% of TAVI recipients and was associated with a higher AS severity. NOAF detection determined the start of anticoagulation therapy in about half of the patients, and it was not associated with an increased risk of clinical events at 1-year follow-up.


Assuntos
Estenose da Valva Aórtica , Fibrilação Atrial , Eletrocardiografia Ambulatorial , Substituição da Valva Aórtica Transcateter , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Feminino , Masculino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Estenose da Valva Aórtica/cirurgia , Idoso de 80 Anos ou mais , Eletrocardiografia Ambulatorial/métodos , Fatores de Risco , Resultado do Tratamento
2.
Open Heart ; 11(1)2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38719497

RESUMO

BACKGROUND: The treatment of pulmonary hypertension (PH) has improved rapidly in recent decades. There is increasing evidence to support the role of early intervention and treatment in affecting clinical outcomes in PH. OBJECTIVES: To assess treatment effects before and after the escalation of specific PH treatments using continuous heart monitoring with a Reveal LINQ loop recorder. METHODS: Patients were compared before and after treatment escalation. Treatment escalation was defined as an additional pulmonary arterial hypertension (PAH) drug, pulmonary endarterectomy, percutaneous balloon angioplasty or bilateral lung transplantation. Specifically, changes in heart rate variability (HRV), heart rate (HR) and physical activity were assessed. RESULTS: In this prospective study, 41 patients (27 with PAH and 14 with chronic thromboembolic pulmonary hypertension (CTEPH)) were enrolled. Among them, 15 (36.6%) patients underwent PH treatment escalation. Prior to escalation, patients were monitored for a median of 100 (range: 68-100) days and after therapy escalation for a median duration of 165 (range: 89-308) days. In the escalation group, there was a significant increase in HRV, physical activity indexed by daytime HR and a significant decrease in nighttime HR assessed at baseline and after treatment escalation in both the PAH and CTEPH groups. This was paralleled by significant improvements in WHO functional class, 6-min walking distance and N-terminal pro-b-type natriuretic peptide. CONCLUSIONS: This is the first study to demonstrate an association between specific PH therapies and changes in HRV, HR nighttime and physical activity. This indicates the potential of continuous monitoring in the evaluation of treatment effects in PH.


Assuntos
Frequência Cardíaca , Hipertensão Pulmonar , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Frequência Cardíaca/fisiologia , Hipertensão Pulmonar/fisiopatologia , Hipertensão Pulmonar/diagnóstico , Hipertensão Pulmonar/terapia , Resultado do Tratamento , Endarterectomia/métodos , Idoso , Anti-Hipertensivos/uso terapêutico , Fatores de Tempo , Angioplastia com Balão/métodos , Adulto , Transplante de Pulmão , Eletrocardiografia Ambulatorial/métodos , Artéria Pulmonar/fisiopatologia
3.
J Am Heart Assoc ; 13(11): e032465, 2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38804218

RESUMO

BACKGROUND: New methods to identify patients who benefit from a primary prophylactic implantable cardioverter-defibrillator (ICD) are needed. T-wave alternans (TWA) has been shown to associate with arrhythmogenesis of the heart and sudden cardiac death. We hypothesized that TWA might be associated with benefit from ICD implantation in primary prevention. METHODS AND RESULTS: In the EU-CERT-ICD (European Comparative Effectiveness Research to Assess the Use of Primary Prophylactic Implantable Cardioverter-Defibrillators) study, we prospectively enrolled 2327 candidates for primary prophylactic ICD. A 24-hour Holter monitor reading was taken from all recruited patients at enrollment. TWA was assessed from Holter monitoring using the modified moving average method. Study outcomes were all-cause death, appropriate shock, and survival benefit. TWA was assessed both as a contiguous variable and as a dichotomized variable with cutoff points <47 µV and <60 µV. The final cohort included 1734 valid T-wave alternans samples, 1211 patients with ICD, and 523 control patients with conservative treatment, with a mean follow-up time of 2.3 years. TWA ≥60 µV was a predicter for a higher all-cause death in patients with an ICD on the basis of a univariate Cox regression model (hazard ratio, 1.484 [95% CI, 1.024-2.151]; P=0.0374; concordance statistic, 0.51). In multivariable models, TWA was not prognostic of death or appropriate shocks in patients with an ICD. In addition, TWA was not prognostic of death in control patients. In a propensity score-adjusted Cox regression model, TWA was not a predictor of ICD benefit. CONCLUSIONS: T-wave alternans is poorly prognostic in patients with a primary prophylactic ICD. Although it may be prognostic of life-threatening arrhythmias and sudden cardiac death in several patient populations, it does not seem to be useful in assessing benefit from ICD therapy in primary prevention among patients with an ejection fraction of ≤35%.


Assuntos
Morte Súbita Cardíaca , Desfibriladores Implantáveis , Eletrocardiografia Ambulatorial , Prevenção Primária , Humanos , Prevenção Primária/métodos , Masculino , Feminino , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/etiologia , Pessoa de Meia-Idade , Idoso , Estudos Prospectivos , Eletrocardiografia Ambulatorial/métodos , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/efeitos adversos , Medição de Risco/métodos , Fatores de Risco , Arritmias Cardíacas/terapia , Arritmias Cardíacas/fisiopatologia , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/prevenção & controle , Arritmias Cardíacas/mortalidade , Resultado do Tratamento , Valor Preditivo dos Testes , Fatores de Tempo , Europa (Continente)/epidemiologia , Prognóstico , Frequência Cardíaca/fisiologia
4.
J Med Syst ; 48(1): 57, 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38801649

RESUMO

Wearable electronics are increasingly common and useful as health monitoring devices, many of which feature the ability to record a single-lead electrocardiogram (ECG). However, recording the ECG commonly requires the user to touch the device to complete the lead circuit, which prevents continuous data acquisition. An alternative approach to enable continuous monitoring without user initiation is to embed the leads in a garment. This study assessed ECG data obtained from the YouCare device (a novel sensorized garment) via comparison with a conventional Holter monitor. A cohort of thirty patients (age range: 20-82 years; 16 females and 14 males) were enrolled and monitored for twenty-four hours with both the YouCare device and a Holter monitor. ECG data from both devices were qualitatively assessed by a panel of three expert cardiologists and quantitatively analyzed using specialized software. Patients also responded to a survey about the comfort of the YouCare device as compared to the Holter monitor. The YouCare device was assessed to have 70% of its ECG signals as "Good", 12% as "Acceptable", and 18% as "Not Readable". The R-wave, independently recorded by the YouCare device and Holter monitor, were synchronized within measurement error during 99.4% of cardiac cycles. In addition, patients found the YouCare device more comfortable than the Holter monitor (comfortable 22 vs. 5 and uncomfortable 1 vs. 18, respectively). Therefore, the quality of ECG data collected from the garment-based device was comparable to a Holter monitor when the signal was sufficiently acquired, and the garment was also comfortable.


Assuntos
Eletrocardiografia Ambulatorial , Eletrocardiografia , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Adulto , Eletrocardiografia Ambulatorial/instrumentação , Eletrocardiografia Ambulatorial/métodos , Idoso de 80 Anos ou mais , Eletrocardiografia/instrumentação , Eletrocardiografia/métodos , Dispositivos Eletrônicos Vestíveis , Adulto Jovem , Vestuário , Processamento de Sinais Assistido por Computador/instrumentação
5.
Open Heart ; 11(1)2024 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-38719499

RESUMO

OBJECTIVE: Implantable loop recorders (ILRs) are increasingly used for long-term rhythm monitoring after ischaemic and cryptogenic stroke, with the goal of detecting atrial fibrillation (AF) and subsequent initiation of oral anticoagulation to reduce risk of adverse clinical outcomes. There is a need to determine the effectiveness of different rhythm monitoring strategies in this context. METHODS: We conducted a retrospective cohort analysis of individuals with commercial and Medicare Advantage insurance in Optum Labs Data Warehouse who had incident ischaemic or cryptogenic stroke and no prior cardiovascular implantable electronic device from 1 January 2016 to 30 June 2021. Patients were stratified by rhythm monitoring strategy: ILR, long-term continuous external cardiac monitor (>48 hours to 30 days) or Holter monitor (≤48 hours). The primary outcome was risk-adjusted all-cause mortality at 12 months. Secondary outcomes included new diagnosis of AF and oral anticoagulation, bleeding, and costs. RESULTS: Among 48 901 patients with ischaemic or cryptogenic stroke, 9235 received an ILR, 29 103 long-term continuous external monitor and 10 563 Holter monitor only. Mean age was 69.9 (SD 11.9) years and 53.5% were female. During the 12-month follow-up period, patients who received ILRs compared with those who received long-term continuous external monitors had a higher odds of new diagnosis of AF and oral anticoagulant initiation (adjusted OR 2.27, 95% CI 2.09 to 2.48). Compared with patients who received long-term continuous external monitors, those who received ILRs had similar 12-month mortality (HR 1.00; 95% CI 0.89 to 1.12), with approximately $13 000 higher costs at baseline (including monitor cost) and $2500 higher costs during 12-month follow-up. CONCLUSIONS: In this large real-world study of patients with ischaemic or cryptogenic stroke, ILR placement resulted in more diagnosis of AF and initiation of oral anticoagulation, but no difference in mortality compared with long-term continuous external monitors.


Assuntos
Fibrilação Atrial , Eletrocardiografia Ambulatorial , AVC Isquêmico , Humanos , Feminino , Masculino , Idoso , Estudos Retrospectivos , Eletrocardiografia Ambulatorial/instrumentação , Eletrocardiografia Ambulatorial/economia , Eletrocardiografia Ambulatorial/métodos , AVC Isquêmico/economia , AVC Isquêmico/mortalidade , AVC Isquêmico/diagnóstico , AVC Isquêmico/prevenção & controle , AVC Isquêmico/etiologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/economia , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/complicações , Fibrilação Atrial/mortalidade , Estados Unidos/epidemiologia , Anticoagulantes/economia , Anticoagulantes/administração & dosagem , Fatores de Tempo , Pessoa de Meia-Idade , Seguimentos , Análise Custo-Benefício , Idoso de 80 Anos ou mais , Custos de Cuidados de Saúde
6.
Comput Methods Programs Biomed ; 249: 108157, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38582037

RESUMO

BACKGROUND AND OBJECTIVE: T-wave alternans (TWA) is a fluctuation in the repolarization morphology of the ECG. It is associated with cardiac instability and sudden cardiac death risk. Diverse methods have been proposed for TWA analysis. However, TWA detection in ambulatory settings remains a challenge due to the absence of standardized evaluation metrics and detection thresholds. METHODS: In this work we use traditional TWA analysis signal processing-based methods for feature extraction, and two machine learning (ML) methods, namely, K-nearest-neighbor (KNN) and random forest (RF), for TWA detection, addressing hyper-parameter tuning and feature selection. The final goal is the detection in ambulatory recordings of short, non-sustained and sparse TWA events. RESULTS: We train ML methods to detect a wide variety of alternant voltage from 20 to 100 µV, i.e., ranging from non-visible micro-alternans to TWA of higher amplitudes, to recognize a wide range in concordance to risk stratification. In classification, RF outperforms significantly the recall in comparison with the signal processing methods, at the expense of a small lost in precision. Despite ambulatory detection stands for an imbalanced category context, the trained ML systems always outperform signal processing methods. CONCLUSIONS: We propose a comprehensive integration of multiple variables inspired by TWA signal processing methods to fed learning-based methods. ML models consistently outperform the best signal processing methods, yielding superior recall scores.


Assuntos
Arritmias Cardíacas , Eletrocardiografia Ambulatorial , Humanos , Eletrocardiografia Ambulatorial/métodos , Frequência Cardíaca , Arritmias Cardíacas/diagnóstico , Morte Súbita Cardíaca , Processamento de Sinais Assistido por Computador , Eletrocardiografia/métodos
7.
Heart ; 110(12): 831-837, 2024 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-38580434

RESUMO

BACKGROUND: Elevated heart rate (HR) predicts cardiovascular disease and mortality, but there are no established normal limits for ambulatory HR. We used data from the Swedish CArdioPulmonary Imaging Study to determine reference ranges for ambulatory HR in a middle-aged population. We also studied clinical correlates of ambulatory HR. METHODS: A 24-hour ECG was registered in 5809 atrial fibrillation-free individuals, aged 50-65 years. A healthy subset (n=3942) was used to establish reference values (excluding persons with beta-blockers, cardiovascular disease, hypertension, heart failure, anaemia, diabetes, sleep apnoea or chronic obstructive pulmonary disease).Minimum HR was defined as the lowest 1-minute HR. Reference ranges are reported as means±SDs and 2.5th-97.5th percentiles. Clinical correlates of ambulatory HR were analysed with multivariable linear regression. RESULTS: The average mean and minimum HRs were 73±9 and 48±7 beats per minute (bpm) in men and 76±8 and 51±7 bpm in women; the reference range for mean ambulatory HR was 57-90 bpm in men and 61-92 bpm in women. Average daytime and night-time HRs are also reported. Clinical correlates, including age, sex, height, body mass index, physical activity, smoking, alcohol intake, diabetes, hypertension, haemoglobin level, use of beta-blockers, estimated glomerular filtration rate, per cent of predicted forced expiratory volume in 1 s and coronary artery calcium score, explained <15% of the interindividual differences in HR. CONCLUSION: Ambulatory HR varies widely in healthy middle-aged individuals, a finding with relevance for the management of patients with a perception of tachycardia. Differences in ambulatory HR between individuals are largely independent of common clinical correlates.


Assuntos
Eletrocardiografia Ambulatorial , Frequência Cardíaca , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Frequência Cardíaca/fisiologia , Valores de Referência , Idoso , Eletrocardiografia Ambulatorial/métodos , Suécia/epidemiologia , Fatores Etários
8.
Int J Cardiol ; 406: 132070, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38643802

RESUMO

BACKGROUND: Cardiac involvement represents a major cause of morbidity and mortality in patients with myotonic dystrophy type 1 (DM1) and prevention of sudden cardiac death (SCD) is a central part of patient care. We investigated the natural history of cardiac involvement in patients with DM1 to provide an evidence-based foundation for adjustment of follow-up protocols. METHODS: Patients with genetically confirmed DM1 were identified. Data on patient characteristics, performed investigations (12 lead ECG, Holter monitoring and echocardiography), and clinical outcomes were retrospectively collected from electronic health records. RESULTS: We included 195 patients (52% men) with a mean age at baseline evaluation of 41 years (range 14-79). The overall prevalence of cardiac involvement increased from 42% to 66% after a median follow-up of 10.5 years. There was a male predominance for cardiac involvement at end of follow-up (74 vs. 44%, p < 0.001). The most common types of cardiac involvement were conduction abnormalities (48%), arrhythmias (35%), and left ventricular systolic dysfunction (21%). Only 17% of patients reported cardiac symptoms. The standard 12­lead ECG was the most sensitive diagnostic modality and documented cardiac involvement in 24% at baseline and in 49% at latest follow-up. However, addition of Holter monitoring and echocardiography significantly increased the diagnostic yield with 18 and 13% points at baseline and latest follow-up, respectively. Despite surveillance 35 patients (18%) died during follow-up; seven due to SCD. CONCLUSIONS: In patients with DM1 cardiac involvement was highly prevalent and developed during follow-up. These findings justify lifelong follow-up with ECG, Holter, and echocardiography. CLINICAL PERSPECTIVE: What is new? What are the clinical implications?


Assuntos
Distrofia Miotônica , Humanos , Distrofia Miotônica/complicações , Distrofia Miotônica/diagnóstico , Distrofia Miotônica/fisiopatologia , Distrofia Miotônica/epidemiologia , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Seguimentos , Adulto Jovem , Estudos Retrospectivos , Adolescente , Idoso , Eletrocardiografia Ambulatorial/métodos , Ecocardiografia/métodos , Cardiopatias/etiologia , Cardiopatias/diagnóstico , Cardiopatias/epidemiologia , Eletrocardiografia
9.
IEEE J Biomed Health Inform ; 28(6): 3457-3465, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38557616

RESUMO

A novel method for tracking the tidal volume (TV) from electrocardiogram (ECG) is presented. The method is based on the amplitude of ECG-derived respiration (EDR) signals. Three different morphology-based EDR signals and three different amplitude estimation methods have been studied, leading to a total of 9 amplitude-EDR (AEDR) signals per ECG channel. The potential of these AEDR signals to track the changes in TV was analyzed. These methods do not need a calibration process. In addition, a personalized-calibration approach for TV estimation is proposed, based on a linear model that uses all AEDR signals from a device. All methods have been validated with two different ECG devices: a commercial Holter monitor, and a custom-made wearable armband. The lowest errors for the personalized-calibration methods, compared to a reference TV, were -3.48% [-17.41% / 12.93%] (median [first quartile / third quartile]) for the Holter monitor, and 0.28% [-10.90% / 17.15%] for the armband. On the other hand, medians of correlations to the reference TV were higher than 0.8 for uncalibrated methods, while they were higher than 0.9 for personal-calibrated methods. These results suggest that TV changes can be tracked from ECG using either a conventional (Holter) setup, or our custom-made wearable armband. These results also suggest that the methods are not as reliable in applications that induce small changes in TV, but they can be potentially useful for detecting large changes in TV, such as sleep apnea/hypopnea and/or exacerbations of a chronic respiratory disease.


Assuntos
Eletrocardiografia Ambulatorial , Processamento de Sinais Assistido por Computador , Volume de Ventilação Pulmonar , Dispositivos Eletrônicos Vestíveis , Humanos , Eletrocardiografia Ambulatorial/instrumentação , Eletrocardiografia Ambulatorial/métodos , Volume de Ventilação Pulmonar/fisiologia , Masculino , Adulto , Feminino , Eletrocardiografia/métodos , Eletrocardiografia/instrumentação , Pessoa de Meia-Idade , Adulto Jovem
10.
Europace ; 26(5)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38584469

RESUMO

AIMS: Brugada syndrome (BrS) diagnosis and risk stratification rely on the presence of a spontaneous type 1 (spT1) electrocardiogram (ECG) pattern; however, its spontaneous fluctuations may lead to misdiagnosis and risk underestimation. This study aims to assess the role for repeat high precordial lead (HPL) resting and ambulatory ECG monitoring in identifying a spT1, and evaluate its prognostic role. METHODS AND RESULTS: HPL resting and ambulatory monitoring ECGs of BrS subjects were reviewed retrospectively, and the presence of a spT1 associated with ventricular dysrhythmias and sudden cardiac death (SCD). Three-hundred and fifty-eight subjects (77 with spT1 pattern at presentation, Group 1, and 281 without, Group 2) were included. In total, 1651 resting HPL resting and 621 ambulatory monitoring ECGs were available for review, or adequately described. Over a median follow-up of 72 months (interquartile range - IQR - 75), 42/77 (55%) subjects in Group 1 showed a spT1 in at least one ECG. In Group 2, 36/281 subjects (13%) had a newly detected spT1 (1.9 per 100 person-year) and 23 on an HPL ambulatory recording (8%). Seven previously asymptomatic subjects, five of whom had a spT1 (four at presentation and one at follow-up), experienced arrhythmic events; survival analysis indicated that a spT1, either at presentation or during lifetime, was associated with events. Univariate models showed that a spT1 was consistently associated with increased risk [spT1 at presentation: hazard ratio (HR) 6.3, 95% confidence interval (CI) 1.4-28, P = 0.016; spT1 at follow-up: HR 3.1, 95% CI 1.3-7.2, P = 0.008]. CONCLUSION: Repeated ECG evaluation and HPL ambulatory monitoring are vital in identifying transient spT1 Brugada pattern and its associated risk.


Assuntos
Síndrome de Brugada , Morte Súbita Cardíaca , Eletrocardiografia Ambulatorial , Humanos , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/fisiopatologia , Masculino , Feminino , Eletrocardiografia Ambulatorial/métodos , Pessoa de Meia-Idade , Estudos Retrospectivos , Prognóstico , Adulto , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Medição de Risco , Valor Preditivo dos Testes , Fatores de Risco , Frequência Cardíaca , Idoso
11.
Eur Heart J ; 45(14): 1255-1265, 2024 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-38445836

RESUMO

BACKGROUND AND AIMS: Available data on continuous rhythm monitoring by implantable loop recorders (ILRs) in patients with Brugada syndrome (BrS) are scarce. The aim of this multi-centre study was to evaluate the diagnostic yield and clinical implication of a continuous rhythm monitoring strategy by ILRs in a large cohort of BrS patients and to assess the precise arrhythmic cause of syncopal episodes. METHODS: A total of 370 patients with BrS and ILRs (mean age 43.5 ± 15.9, 33.8% female, 74.1% symptomatic) from 18 international centers were included. Patients were followed with continuous rhythm monitoring for a median follow-up of 3 years. RESULTS: During follow-up, an arrhythmic event was recorded in 30.7% of symptomatic patients [18.6% atrial arrhythmias (AAs), 10.2% bradyarrhythmias (BAs), and 7.3% ventricular arrhythmias (VAs)]. In patients with recurrent syncope, the aetiology was arrhythmic in 22.4% (59.3% BAs, 25.0% VAs, and 15.6% AAs). The ILR led to drug therapy initiation in 11.4%, ablation procedure in 10.9%, implantation of a pacemaker in 2.5%, and a cardioverter-defibrillator in 8%. At multivariate analysis, the presence of symptoms [hazard ratio (HR) 2.5, P = .001] and age >50 years (HR 1.7, P = .016) were independent predictors of arrhythmic events, while inducibility of ventricular fibrillation at the electrophysiological study (HR 9.0, P < .001) was a predictor of VAs. CONCLUSIONS: ILR detects arrhythmic events in nearly 30% of symptomatic BrS patients, leading to appropriate therapy in 70% of them. The most commonly detected arrhythmias are AAs and BAs, while VAs are detected only in 7% of cases. Symptom status can be used to guide ILR implantation.


Assuntos
Síndrome de Brugada , Desfibriladores Implantáveis , Marca-Passo Artificial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Arritmias Cardíacas/complicações , Arritmias Cardíacas/diagnóstico , Síndrome de Brugada/complicações , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/terapia , Eletrocardiografia/métodos , Eletrocardiografia Ambulatorial/métodos , Adulto
12.
J Am Heart Assoc ; 13(5): e032890, 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38390808

RESUMO

BACKGROUND: Implantable loop recorders (ILRs) are increasingly placed for arrhythmia detection. However, historically, ≈75% of ILR alerts are false positives, requiring significant time and effort for adjudication. The LINQII and LUX-Dx are remotely reprogrammable ILRs with dual-stage algorithms using artificial intelligence to reduce false positives, but their utility in routine clinical practice has not been studied. METHODS AND RESULTS: We identified patients with the LINQII and LUX-Dx who were monitored by the Veterans Affairs National Cardiac Device Surveillance Program between March and June 2022. ILR programming was customized on the basis of implant indication. All alerts and every 90-day scheduled transmissions were manually reviewed. ILRs were remotely reprogrammed, as appropriate, after false-positive alerts or 2 consecutive same-type alerts, unless there was ongoing clinical need for that alert. Outcomes were total number of transmissions and false positives. We performed medical record review to determine if patients experienced any adverse clinical events, including hospitalization and mortality. Among 117 LINQII patients, there were 239 total alerts, 43 (18.0%) of which were false positives. Among 105 LUX-Dx patients, there were 300 total alerts, 115 (38.3%) of which were false positives. LINQIIs were reprogrammed 22 times, resulting in a decrease in median alerts/day from 0.13 to 0.03. LUX-Dx ILRs were reprogrammed 52 times, resulting in a decrease from 0.15 to 0.01 median alerts/day. There were no adverse clinical events that could have been identified by superior or earlier arrhythmia detection. CONCLUSIONS: ILRs with artificial intelligence algorithms and remote reprogramming ability are associated with reduced alert burden because of higher true-positive rates than prior ILRs, without missing potentially consequential arrhythmias.


Assuntos
Arritmias Cardíacas , Inteligência Artificial , Humanos , Arritmias Cardíacas/diagnóstico , Próteses e Implantes , Algoritmos , Diagnóstico Precoce , Eletrocardiografia Ambulatorial/métodos
14.
Heart Rhythm ; 21(5): 530-537, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38350520

RESUMO

BACKGROUND: Pulmonary vein isolation (PVI) is the cornerstone of atrial fibrillation (AF) ablation. A blanking period (BP) of 3 months is used in clinical trials and practice. However, the optimal BP duration after PVI remains undefined. OBJECTIVE: The aim of this study was to objectively define, using continuous monitoring by an implantable loop recorder, the optimal BP duration after cryoballoon PVI. METHODS: We enrolled consecutive patients who had cryoballoon PVI and an implantable loop recorder. We determined the time of the last confirmed episode of AF within the blanking period. This was then correlated with AF recurrence in the first year after ablation. RESULTS: There were 210 patients (66 ± 9 years; 138 [66%] male; 116 [55%] paroxysmal AF; CHA2DS2-VASc score, 2.5 ± 1.6). We defined 4 distinct groups based on the last AF episode within the BP: no AF days 0-90 (n = 96 [46%]) and last AF 0-30 days (n = 46 [22%]), 31-60 days (n = 18 [9%]), and 61-90 days (n = 50 [24%]). After the 3-month BP, 101 (48%) patients had AF recurrence at 160 ± 86 days. Compared with patients with no AF in the BP, those with recurrent AF and AF burden >0% 30 days after ablation had a significantly greater AF recurrence during long-term follow-up (P = .001). CONCLUSION: Our data show that the approximately one-third of patients in whom AF occurs and who have a burden of >0% after the first month that follows PVI are at significantly higher risk of long-term recurrent AF. We therefore suggest that the blanking period be limited to a month after cryoballoon PVI.


Assuntos
Fibrilação Atrial , Criocirurgia , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Masculino , Feminino , Criocirurgia/métodos , Idoso , Seguimentos , Recidiva , Resultado do Tratamento , Eletrocardiografia Ambulatorial/métodos , Fatores de Tempo , Sistema de Condução Cardíaco/fisiopatologia , Sistema de Condução Cardíaco/cirurgia , Pessoa de Meia-Idade , Ablação por Cateter/métodos , Estudos Retrospectivos , Eletrocardiografia/métodos
15.
J Electrocardiol ; 83: 12-20, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38185007

RESUMO

BACKGROUND: T-wave alternans (TWA) analysis was shown in >14,000 individuals studied worldwide over the past two decades to be a useful tool to assess risk for cardiovascular mortality and sudden arrhythmic death. TWA analysis by the modified moving average (MMA) method is FDA-cleared and CMS-reimbursed (CAG-00293R2). OBJECTIVE: Because the MMA technique is inherently suitable for dynamic tracking of alternans levels, it was selected for development of artificial intelligence (AI)-enabled algorithms using convolutional neural networks (CNN) to achieve rapid, efficient, and accurate assessment of P-wave alternans (PWA), R-wave alternans (RWA), and TWA. METHODS: The novel application of CNN algorithms to enhance MMA analysis generated efficient and powerful pattern-recognition algorithms for highly accurate alternans quantification. Algorithm reliability and accuracy were verified using simulated ECGs achieving R2 ≥ 0.99 (p < 0.01) in response to noise inputs and artifacts that emulate real-life conditions. RESULTS: Accuracy of the new AI-MMA algorithms in TWA analysis (n = 5) was significantly improved over unsupervised, automated MMA output (p = 0.036) and did not differ from conventional MMA analysis with expert overreading (p = 0.21). Accuracy of AI-MMA in PWA analysis (n = 45) was significantly improved over unsupervised, automated MMA output (p < 0.005) and did not differ from conventional MMA analysis with expert overreading (p = 0.89). TWA and PWA by AI-MMA were correlated with conventional MMA output over-read by an expert reader (R2 = 0.7765, R2 = 0.9504, respectively). CONCLUSION: This novel technique for AI-MMA analysis could be suitable for use in diverse in-hospital and out-of-hospital monitoring systems, including cardiac implantable electronic devices and smartwatches, for tracking atrial and ventricular arrhythmia risk.


Assuntos
Inteligência Artificial , Eletrocardiografia , Humanos , Eletrocardiografia/métodos , Reprodutibilidade dos Testes , Eletrocardiografia Ambulatorial/métodos , Arritmias Cardíacas , Redes Neurais de Computação , Átrios do Coração
16.
Heart Rhythm ; 21(5): 581-589, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38246569

RESUMO

BACKGROUND: The Apple Watch™ (AW) offers heart rate (HR) tracking by photoplethysmography (PPG) and single-lead electrocardiographic (ECG) recordings. The accuracy of AW-HR and diagnostic performance of AW-ECGs among children during both sinus rhythm and arrhythmias have not been explored. OBJECTIVE: The purposes of this study were to assess the accuracy of AW-HR measurements compared to gold standard modalities in children during sinus rhythm and arrhythmias and to identify non-sinus rhythms using AW-ECGs. METHODS: Subjects ≤18 years wore an AW during (1) telemetry admission, (2) electrophysiological study (EPS), or (3) exercise stress test (EST). AW-HRs were compared to gold standard modality values. Recorded AW-ECGs were reviewed by 3 blinded pediatric electrophysiologists. RESULTS: Eighty subjects (median age 13 years; interquartile range 1.0-16.0 years; 50% female) wore AW (telemetry 41% [n = 33]; EPS 34% [n = 27]; EST 25% [n = 20]). A total of 1090 AW-HR measurements were compared to time-synchronized gold standard modality HR values. Intraclass correlation coefficient (ICC) was high 0.99 (0.98-0.99) for AW-HR during sinus rhythm compared to gold standard modalities. ICC was poor comparing AW-HR to gold standard modality HR in tachyarrhythmias (ICC 0.24-0.27) due to systematic undercounting of AW-HR values. A total of 126 AW-ECGs were reviewed. Identification of non-sinus rhythm by AW-ECG showed sensitivity of 89%-96% and specificity of 78%-87%. CONCLUSIONS: We found high levels of agreement for AW-HR values with gold standard modalities during sinus rhythm and poor agreement during tachyarrhythmias, likely due to hemodynamic effects of tachyarrhythmias on PPG-based measurements. AW-ECGs had good sensitivity and moderate specificity in identification of non-sinus rhythm in children.


Assuntos
Arritmias Cardíacas , Frequência Cardíaca , Fotopletismografia , Humanos , Feminino , Masculino , Criança , Adolescente , Frequência Cardíaca/fisiologia , Pré-Escolar , Lactente , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Fotopletismografia/métodos , Fotopletismografia/instrumentação , Reprodutibilidade dos Testes , Telemetria/instrumentação , Telemetria/métodos , Dispositivos Eletrônicos Vestíveis , Eletrocardiografia/métodos , Desenho de Equipamento , Eletrocardiografia Ambulatorial/métodos , Eletrocardiografia Ambulatorial/instrumentação , Teste de Esforço/métodos
17.
Heart Rhythm ; 21(5): 521-529, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38246570

RESUMO

BACKGROUND: Early recurrence of atrial tachyarrhythmia (ERAT) is associated with ablation-induced proarrhythmogenic inflammation; however, existing studies used intermittent monitoring or nonoptimized radiofrequency (RF) applications (noncontiguous or without ablation index target value). OBJECTIVE: The purpose of this study was to investigate the relationship between ERAT and late recurrence based on insertable cardiac monitor (ICM) data. METHODS: We compiled data from Close-To-Cure and Close Maze studies, which enrolled patients who underwent RF ablation for paroxysmal or persistent atrial fibrillation (AF). All patients were implanted with an ICM 2-3 months before ablation. RESULTS: We studied 165 patients (104 with paroxysmal AF, 61 with persistent AF). Over the 1-year follow-up period, 41 of the patients experienced late recurrence. The risk of late recurrence was higher in patients experiencing ERAT (hazard ratio [HR] 6.2; 95% confidence interval [CI] 3.0-13.0), with negative and positive predictive values of 90.5% and 45.7%, respectively. Median burden of AF during the blanking period was significantly higher in patients with late recurrence (7.9% [0.0%-99.6%]) compared to those without recurrence (0.0% [0.0%-6.0]; P <.001). For each 1% increase in AF burden during the blanking period, late recurrence increased by 4.6% (HR 1.046; 95% CI 1.035-1.059). The best tradeoff for predicting AF from ERAT occurrence was AF burden of 0.6% and last ERAT at 64 days. CONCLUSION: In patients ablated for paroxysmal and persistent AF with a durable RF lesion set and implanted with a continuous monitoring device, postablation early AF recurrence and burden significantly predict late recurrence. The post-AF ablation blanking period should be reduced to 2 months.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Eletrocardiografia Ambulatorial , Recidiva , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Masculino , Feminino , Ablação por Cateter/métodos , Pessoa de Meia-Idade , Eletrocardiografia Ambulatorial/métodos , Eletrocardiografia Ambulatorial/instrumentação , Seguimentos , Idoso , Fatores de Tempo , Resultado do Tratamento , Estudos Retrospectivos
18.
J Am Heart Assoc ; 13(3): e031508, 2024 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-38240210

RESUMO

BACKGROUND: Atrial fibrillation (AF) is known to be a strong risk factor for stroke. However, the risk of stroke recurrence in patients with cryptogenic stroke with AF detected after stroke by an insertable cardiac monitor (ICM) is not well known. We sought to evaluate the risk of ischemic stroke recurrence in patients with cryptogenic stroke with and without ICM-detected AF. METHODS AND RESULTS: We retrospectively reviewed patients with cryptogenic stroke who underwent ICM implantation at 8 stroke centers in Japan. Cox regression models were developed using landmark analysis and time-dependent analysis. We set the target sample size at 300 patients based on our estimate of the annualized incidence of ischemic stroke recurrence to be 3% in patients without AF detection and 9% in patients with AF detection. Of the 370 patients, 121 were found to have AF, and 110 received anticoagulation therapy after AF detection. The incidence of ischemic stroke recurrence was 4.0% in 249 patients without AF detection and 5.8% in 121 patients with AF detection (P=0.45). In a landmark analysis, the risk of ischemic stroke recurrence was not higher in patients with AF detected ≤90 days than in those without (hazard ratio, 1.47 [95% CI, 0.41-5.28]). In a time-dependent analysis, the risk of ischemic stroke recurrence did not increase after AF detection (hazard ratio, 1.77 [95% CI, 0.70-4.47]). CONCLUSIONS: The risk of ischemic stroke recurrence in patients with cryptogenic stroke with ICM-detected AF, 90% of whom were subsequently anticoagulated, was not higher than in those without ICM-detected AF.


Assuntos
Fibrilação Atrial , AVC Isquêmico , Acidente Vascular Cerebral , Humanos , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , AVC Isquêmico/complicações , Estudos Retrospectivos , Eletrocardiografia Ambulatorial/métodos , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia
19.
Telemed J E Health ; 30(5): 1499-1503, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38294864

RESUMO

Telemedicine and remote monitoring devices, including implantable loop recorders (ILR), are increasingly adopted in the cardiologic setting. These are valuable tools in the arrhythmic stratification of patients at risk of sudden cardiac death, providing a tailored therapeutic management to prevent lethal arrhythmias. We report a case of an asymptomatic 18-year-old boy with a family history of syncope and cardiac arrest, who had a diagnosis of Brugada syndrome with an inducible type 1 pattern and carrier of a missense mutation of the SCN5A gene. In light of the risk factors, although not recommended by current guidelines, we decided to proceed with the implantation of an ILR with remote monitoring service. A few months later, an episode of asymptomatic sustained polymorphic ventricular tachycardia was promptly observed by the remote monitoring, leading to a timely implantation of a subcutaneous cardiac implantable defibrillator.


Assuntos
Síndrome de Brugada , Desfibriladores Implantáveis , Telemedicina , Humanos , Masculino , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/genética , Síndrome de Brugada/terapia , Adolescente , Telemedicina/métodos , Medição de Risco/métodos , Canal de Sódio Disparado por Voltagem NAV1.5/genética , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Eletrocardiografia , Eletrocardiografia Ambulatorial/instrumentação , Eletrocardiografia Ambulatorial/métodos , Mutação de Sentido Incorreto , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/etiologia
20.
Eur Radiol ; 34(1): 155-164, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37555957

RESUMO

OBJECTIVES: To investigate the feasibility of breast MRI exams and guided biopsies in patients with an implantable loop recorder (ILR) as well as the impact ILRs may have on image interpretation. MATERIALS AND METHODS: This retrospective study examined breast MRIs of patients with ILR, from April 2008 to September 2022. Radiological reports and electronic medical records were reviewed for demographic characteristics, safety concerns, and imaging findings. MR images were analyzed and compared statistically for artifact quantification on the various pulse sequences. RESULTS: Overall, 40/82,778 (0.049%) MRIs during the study period included ILR. All MRIs were completed without early termination. No patient-related or device-related adverse events occurred. ILRs were most commonly located in the left lower-inner quadrant (64.6%). The main artifact was a signal intensity (SI) void in a dipole formation in the ILR bed with or without areas of peripheral high SI. Artifacts appeared greatest in the cranio-caudal axis (p < 0.001), followed by the anterior-posterior axis (p < 0.001), and then the right-left axis. High peripheral rim-like SI artifacts appeared on the post-contrast and subtracted T1-weighted images, mimicking suspicious enhancement. Artifacts were most prominent on diffusion-weighted (p < 0.001), followed by T2-weighted and T1-weighted images. In eight patients, suspicious findings were found on MRI, resulting in four additional malignant lesions. Of six patients with left breast cancer, the tumor was completely visible in five cases and partially obscured in one. CONCLUSION: Breast MRI is feasible and safe among patients with ILR and may provide a significant diagnostic value, albeit with localized, characteristic artifacts. CLINICAL RELEVANCE STATEMENT: Indicated breast MRI exams and guided biopsies can be safely performed in patients with implantable loop recorder. Nevertheless, radiologists should be aware of associated limitations including limited assessment of the inner left breast and pseudo-enhancement artifacts. KEY POINTS: • Breast MRI in patients with an implantable loop recorder is an infrequent, feasible, and safe procedure. • Despite limited breast visualization of the implantable loop recorder bed and characteristic artifacts, MRI depicted additional lesions in 8/40 (20%) of cases, half of which were malignant. • Breast MRI in patients with an implantable loop recorder should be performed when indicated, taking into consideration typical associated artifacts.


Assuntos
Eletrocardiografia Ambulatorial , Imageamento por Ressonância Magnética , Humanos , Estudos Retrospectivos , Eletrocardiografia Ambulatorial/métodos , Imageamento por Ressonância Magnética/métodos , Próteses e Implantes , Radiografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA