Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 76
Filtrar
1.
Viruses ; 16(8)2024 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-39205164

RESUMO

The novel coronavirus SARS-CoV-2 was first isolated in late 2019; it has spread to all continents, infected over 700 million people, and caused over 7 million deaths worldwide to date. The high transmissibility of the virus and the emergence of novel strains with altered pathogenicity and potential resistance to therapeutics and vaccines are major challenges in the study and treatment of the virus. Ongoing screening efforts aim to identify new cases to monitor the spread of the virus and help determine the danger connected to the emergence of new variants. Given its sensitivity and specificity, nucleic acid amplification tests (NAATs) such as RT-qPCR are the gold standard for SARS-CoV-2 detection. However, due to high costs, complexity, and unavailability in low-resource and point-of-care (POC) settings, the available RT-qPCR assays cannot match global testing demands. An alternative NAAT, RT-LAMP-based SARS-CoV-2 detection offers scalable, low-cost, and rapid testing capabilities. We have developed an automated RT-LAMP-based microfluidic chip that combines the RNA isolation, purification, and amplification steps on the same device and enables the visual detection of SARS-CoV-2 within 40 min from saliva and nasopharyngeal samples. The entire assay is executed inside a uniquely designed, inexpensive disposable microfluidic chip, where assay components and reagents have been optimized to provide precise and qualitative results and can be effectively deployed in POC settings. Furthermore, this technology could be easily adapted for other novel emerging viruses.


Assuntos
COVID-19 , Técnicas de Diagnóstico Molecular , Nasofaringe , Técnicas de Amplificação de Ácido Nucleico , RNA Viral , SARS-CoV-2 , Saliva , Sensibilidade e Especificidade , Humanos , Saliva/virologia , SARS-CoV-2/isolamento & purificação , SARS-CoV-2/genética , Nasofaringe/virologia , COVID-19/diagnóstico , COVID-19/virologia , Técnicas de Amplificação de Ácido Nucleico/métodos , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Diagnóstico Molecular/instrumentação , RNA Viral/genética , RNA Viral/análise , RNA Viral/isolamento & purificação , Dispositivos Lab-On-A-Chip , Teste de Ácido Nucleico para COVID-19/métodos , Teste de Ácido Nucleico para COVID-19/instrumentação , Teste para COVID-19/métodos , Microfluídica/métodos , Microfluídica/instrumentação
2.
Anal Chem ; 96(35): 14197-14204, 2024 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-39161182

RESUMO

Currently, CRISPR/Cas-based molecular diagnostic techniques usually rely on the introduction of nucleic acid amplification to improve their sensitivity, which is usually more time-consuming, susceptible to aerosol contamination, and therefore not suitable for at-home molecular testing. In this research, we developed an advanced CRISPR/Cas13a-Cas12a-based lateral flow assay that facilitated the ultrasensitive and rapid detection of SARS-CoV-2 RNA directly from samples, without the need for nucleic acid amplification. This method was called CRISPR LFA enabling at-home RNA testing (CLEAR). CLEAR used a novel cascade mechanism with specially designed probes that fold into hairpin structures, enabling visual detection of SARS-CoV-2 sequences down to 1 aM sensitivity levels. More importantly, CLEAR had a positive coincidence rate of 100% and a negative coincidence rate of 100% for clinical nasopharyngeal swabs from 16 patients. CLEAR was particularly suitable for at-home molecular testing, providing a low-cost, user-friendly solution that can efficiently distinguish between different SARS-CoV-2 variants. CLEAR overcame the common limitations of high sensitivity and potential contamination associated with traditional PCR-based systems, making it a promising tool for widespread public health application, especially in environments with limited access to laboratory resources.


Assuntos
COVID-19 , Sistemas CRISPR-Cas , RNA Viral , SARS-CoV-2 , SARS-CoV-2/genética , SARS-CoV-2/isolamento & purificação , Humanos , Sistemas CRISPR-Cas/genética , RNA Viral/análise , RNA Viral/genética , COVID-19/diagnóstico , COVID-19/virologia , Teste de Ácido Nucleico para COVID-19/métodos , Teste de Ácido Nucleico para COVID-19/instrumentação , Técnicas de Amplificação de Ácido Nucleico/métodos , Técnicas de Diagnóstico Molecular/métodos , Limite de Detecção
3.
Mil Med ; 189(Supplement_3): 184-189, 2024 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-39160794

RESUMO

INTRODUCTION: Mass screening for SARS-CoV-2 using nasopharyngeal swabs (NPS) is costly, uncomfortable for patients, and increases the chance of virus exposure to health care workers. Therefore, this study focused on determining if self-collected unpreserved saliva can be an effective alternative to NPS collection in COVID-19 surveillance. MATERIALS AND METHODS: In this study, patients being tested for SARS-CoV-2 using NPS were asked to provide a saliva sample to compare their results. NPS samples were evaluated for SARS-CoV-2 using BioFire® FilmArray® Torch® or Cepheid® GeneXpert® systems while saliva samples were evaluated using an in-house developed reverse transcriptase polymerase chain reaction (RT-PCR) which targeted the Envelope (E) and Nucleocapsid (N) genes. RESULTS: Detection of SARS-CoV-2 using self-collected saliva was found to be only slightly less accurate (<5%) than testing using NPS. In addition, initial saliva RT-PCR identified 27 positive subjects, 18 of which provided amplicons sufficient for confirmatory sequencing. The sequencing data showed a genetic shift in the virus within our population sometime between 22 June and July 8, 2021 from Alpha to Delta variant. CONCLUSIONS: The saliva sample collection method identifies the E gene in SARS COVID-2 samples which provides an alternative specimen source to the NPS. This identifies the S gene and ORF1ab. Saliva collection is more convenient to the patient, yields comparable results to NPS collection, and potentially increases Covid-19 surveillance.


Assuntos
Teste de Ácido Nucleico para COVID-19 , COVID-19 , SARS-CoV-2 , Saliva , Manejo de Espécimes , Humanos , Saliva/virologia , SARS-CoV-2/genética , SARS-CoV-2/isolamento & purificação , COVID-19/diagnóstico , COVID-19/virologia , Manejo de Espécimes/métodos , Teste de Ácido Nucleico para COVID-19/métodos , Teste de Ácido Nucleico para COVID-19/instrumentação , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , Nasofaringe/virologia , Teste para COVID-19/métodos , Adulto , Feminino , Masculino
4.
Biosens Bioelectron ; 263: 116626, 2024 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-39116633

RESUMO

In the past, vast research has been conducted on biosensors and point-of-care (PoC) diagnostics. Despite rapid advances especially during the SARS-CoV-2 pandemic in this research field a low-cost molecular biosensor exhibiting the user-friendliness of a rapid antigen test, and also the sensitivity and specificity of a PCR test, has not been developed yet. To this end we developed a novel microfluidics based and handheld PoC device, that facilitates viral detection at PCR sensitivity and specificity in less than 40 min, including 15 min sample preparation. This was attained by incorporation of pulse controlled amplification (PCA), a method which uses short electrical pulses to rapidly increase the temperature of a small fraction of the sample volume. In this work, we present a low-cost PCA device with a microfluidic consumable intended for the use in a decentralized or home-setting. We used finite element analysis (FEA) simulations to display the fundamental principle and highlight the critical parameter dependency of PCA, such as pulse length and resistor shape. Furthermore, we integrated a simple and fast workflow for sample preparation and evaluated the limit of detection (LoD) for SARS-CoV-2 viral RNA, which is 0.88 copies/µL (=44 copies/reaction), and thus, comparable to conventional RT-qPCR. Additionally, target specificity of the device was validated. Our device and PCA approach enables cost-effective, rapid and mobile molecular diagnostics while remaining highly sensitive and specific.


Assuntos
Técnicas Biossensoriais , COVID-19 , SARS-CoV-2 , SARS-CoV-2/isolamento & purificação , SARS-CoV-2/genética , Humanos , COVID-19/diagnóstico , COVID-19/virologia , Técnicas Biossensoriais/instrumentação , Desenho de Equipamento , Técnicas de Amplificação de Ácido Nucleico/instrumentação , Técnicas de Amplificação de Ácido Nucleico/métodos , Teste de Ácido Nucleico para COVID-19/instrumentação , Teste de Ácido Nucleico para COVID-19/métodos , Dispositivos Lab-On-A-Chip , Sistemas Automatizados de Assistência Junto ao Leito , Limite de Detecção , Sensibilidade e Especificidade , RNA Viral/análise , RNA Viral/isolamento & purificação
5.
Analyst ; 149(17): 4418-4424, 2024 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-39011640

RESUMO

The development of ultrasensitive and visual methods is of great significance for molecular diagnosis at the point-of-care. In this study, we have integrated recombinase polymerase amplification (RPA) with the CRISPR-Cas12a system to design an ultrasensitive strategy for visual nucleic acid testing. RPA is utilized to amplify the target nucleic acid, producing amplicons that activate the single-stranded DNase property of CRISPR-Cas12a. The activated CRISPR-Cas12a then degrades the single-stranded DNA on magnetic nanoparticles (MNPs), releasing immobilized GOx from the MNPs which catalyses the chromogenic substrate. The developed method exhibits remarkable sensitivity, successfully detecting as low as 10 aM (∼6 copies per µL) of the target nucleic acid by visual colour changes in solution. The instrumental limit of detection is calculated to be 2.86 aM (∼2 copies per µL), comparable to the sensitivity of polymerase chain reaction (PCR). Importantly, this approach only requires isothermal incubation operation and does not involve costly instruments. The method has been validated by visually detecting the SARS-CoV-2 RNA gene fragment within 50 minutes. With its ultrasensitivity, simplicity of operation, and potential for integration into a point-of-care detection kit, this strategy holds great promise for nucleic acid testing in various settings.


Assuntos
COVID-19 , Sistemas CRISPR-Cas , Limite de Detecção , Técnicas de Amplificação de Ácido Nucleico , RNA Viral , SARS-CoV-2 , SARS-CoV-2/genética , SARS-CoV-2/isolamento & purificação , Sistemas CRISPR-Cas/genética , RNA Viral/análise , RNA Viral/genética , Humanos , Técnicas de Amplificação de Ácido Nucleico/métodos , COVID-19/diagnóstico , COVID-19/virologia , Teste de Ácido Nucleico para COVID-19/métodos , Teste de Ácido Nucleico para COVID-19/instrumentação , Nanopartículas de Magnetita/química , Endodesoxirribonucleases/química , Endodesoxirribonucleases/genética , Proteínas Associadas a CRISPR/genética , DNA de Cadeia Simples/química , DNA de Cadeia Simples/genética , Proteínas de Bactérias
6.
Biomed Environ Sci ; 37(6): 639-646, 2024 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-38988114

RESUMO

Objective: To develop a highly sensitive and rapid nucleic acid detection method for the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Methods: We designed, developed, and manufactured an integrated disposable device for SARS-CoV-2 nucleic acid extraction and detection. The precision of the liquid transfer and temperature control was tested. A comparison between our device and a commercial kit for SARS-Cov-2 nucleic acid extraction was performed using real-time fluorescence reverse transcription polymerase chain reaction (RT-PCR). The entire process, from SARS-CoV-2 nucleic acid extraction to amplification, was evaluated. Results: The precision of the syringe transfer volume was 19.2 ± 1.9 µL (set value was 20), 32.2 ± 1.6 (set value was 30), and 57.2 ± 3.5 (set value was 60). Temperature control in the amplification tube was measured at 60.0 ± 0.0 °C (set value was 60) and 95.1 ± 0.2 °C (set value was 95) respectively. SARS-Cov-2 nucleic acid extraction yield through the device was 7.10 × 10 6 copies/mL, while a commercial kit yielded 2.98 × 10 6 copies/mL. The mean time to complete the entire assay, from SARS-CoV-2 nucleic acid extraction to amplification detection, was 36 min and 45 s. The detection limit for SARS-CoV-2 nucleic acid was 250 copies/mL. Conclusion: The integrated disposable devices may be used for SARS-CoV-2 Point-of-Care test (POCT).


Assuntos
COVID-19 , Equipamentos Descartáveis , RNA Viral , SARS-CoV-2 , SARS-CoV-2/isolamento & purificação , COVID-19/diagnóstico , COVID-19/virologia , Humanos , RNA Viral/isolamento & purificação , RNA Viral/análise , Teste de Ácido Nucleico para COVID-19/instrumentação , Teste de Ácido Nucleico para COVID-19/métodos , Técnicas de Amplificação de Ácido Nucleico/instrumentação , Técnicas de Amplificação de Ácido Nucleico/métodos , Reação em Cadeia da Polimerase em Tempo Real/métodos , Reação em Cadeia da Polimerase em Tempo Real/instrumentação
7.
Anal Chem ; 96(28): 11181-11188, 2024 07 16.
Artigo em Inglês | MEDLINE | ID: mdl-38967089

RESUMO

The COVID-19 pandemic has highlighted the need for rapid and reliable diagnostics that are accessible in resource-limited settings. To address this pressing issue, we have developed a rapid, portable, and electricity-free method for extracting nucleic acids from respiratory swabs (i.e. nasal, nasopharyngeal and buccal swabs), successfully demonstrating its effectiveness for the detection of SARS-CoV-2 in residual clinical specimens. Unlike traditional approaches, our solution eliminates the need for micropipettes or electrical equipment, making it user-friendly and requiring little to no training. Our method builds upon the principles of magnetic bead extraction and revolves around a low-cost plastic magnetic lid, called SmartLid, in combination with a simple disposable kit containing all required reagents conveniently prealiquoted. Here, we clinically validated the SmartLid sample preparation method in comparison to the gold standard QIAamp Viral RNA Mini Kit from QIAGEN, using 406 clinical isolates, including 161 SARS-CoV-2 positives, using the SARS-CoV-2 RT-qPCR assays developed by the US Centers for Disease Control and Prevention (CDC). The SmartLid method showed an overall sensitivity of 95.03% (95% CI: 90.44-97.83%) and a specificity of 99.59% (95% CI: 97.76-99.99%), with a positive agreement of 97.79% (95% CI: 95.84-98.98%) when compared to QIAGEN's column-based extraction method. There are clear benefits to using the SmartLid sample preparation kit: it enables swift extraction of viral nucleic acids, taking less than 5 min, without sacrificing significant accuracy when compared to more expensive and time-consuming alternatives currently available on the market. Moreover, its simplicity makes it particularly well-suited for the point-of-care where rapid results and portability are crucial. By providing an efficient and accessible means of nucleic acid extraction, our approach aims to introduce a step-change in diagnostic capabilities for resource-limited settings.


Assuntos
COVID-19 , RNA Viral , SARS-CoV-2 , Humanos , SARS-CoV-2/isolamento & purificação , SARS-CoV-2/genética , COVID-19/diagnóstico , COVID-19/virologia , RNA Viral/isolamento & purificação , RNA Viral/análise , Teste de Ácido Nucleico para COVID-19/métodos , Teste de Ácido Nucleico para COVID-19/instrumentação , Manejo de Espécimes/métodos , Teste para COVID-19/métodos , Teste para COVID-19/instrumentação , Técnicas de Diagnóstico Molecular/métodos , Região de Recursos Limitados
8.
Talanta ; 278: 126487, 2024 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-39002258

RESUMO

Early screening for pathogens is crucial during pandemic outbreaks. Nucleic acid testing (NAT) is a valuable method for keeping pathogens from spreading. However, the long detection time and large size of the instruments involved significantly limited the efficiency of detection. This work described an integrated NAT microsensor that facilitated rapid and extremely sensitive detection based on nucleic acid amplification (NAA) on a chip. The biochip consisted of two layers incorporating a heater, a thermometer, an interdigital electrode (IDE) and a reaction chamber. The Pt electrode based heater and thermometer were utilized to maintain a specific temperature for the sample in the chamber. The thermometer exhibited a good linear correlation with a sensitivity of 9.36 Ω/°C and the heater achieved a heating efficiency of approximately 6.5 °C/s. Multiple ions were released during NAA, resulting in a decrease in the impedance of the amplification system solution. A large signal of impedance was generated by the released ions due to its linear correlation with the logarithm of the ion concentration. With this detection principle, IDE was employed for real-time monitoring of the in-chip reaction system impedance and NAA process. Specific nucleic acids from two pathogens (SARS-CoV-2, Vibrio vulnificus) were detected with this microsensor. The samples were qualitatively analyzed on microchip within 3 min, with a limit of detection (LOD) of 103 copies/µL. The proposed sensor presented several advantages, including reduced NAT time and increased sensitivity. Consequently, it has shown significant potential in rapid and high-quality nucleic acid testing for the field of epidemic prevention.


Assuntos
Técnicas Biossensoriais , Impedância Elétrica , Técnicas de Amplificação de Ácido Nucleico , SARS-CoV-2 , Técnicas Biossensoriais/métodos , SARS-CoV-2/isolamento & purificação , SARS-CoV-2/genética , Técnicas de Amplificação de Ácido Nucleico/métodos , Humanos , Limite de Detecção , Eletrodos , Dispositivos Lab-On-A-Chip , COVID-19/diagnóstico , COVID-19/virologia , Teste de Ácido Nucleico para COVID-19/métodos , Teste de Ácido Nucleico para COVID-19/instrumentação , RNA Viral/análise , RNA Viral/genética
9.
Lab Chip ; 24(13): 3265-3275, 2024 06 25.
Artigo em Inglês | MEDLINE | ID: mdl-38847067

RESUMO

Throughout the COVID-19 pandemic, individuals potentially infected with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) were forcibly recalled to local or central hospitals, where the diagnostic results were obtained a couple of days after the liquid biopsies were subjected to conventional polymerase chain reaction (PCR). This slow output of such a complex and time-consuming laboratory procedure hindered its widespread application. To overcome the limitations associated with such a centralized diagnostic system, we developed a hand-held and all-in-one type test kit in which the analytical results can be obtained in only 30 min. The test kit consists of three major steps for on-site SARS-CoV-2 RNA detection: 1) virus lysis by heat, 2) RNA enrichment by membrane, and 3) real-time detection by colorimetric loop-mediated isothermal amplification (c-LAMP). The proposed device operates in a sample-to-answer format, is fully automated, and reduces dependence on traditional laboratory settings, facilitating large-scale population screening.


Assuntos
COVID-19 , Colorimetria , Técnicas de Amplificação de Ácido Nucleico , RNA Viral , SARS-CoV-2 , Humanos , SARS-CoV-2/isolamento & purificação , SARS-CoV-2/genética , Colorimetria/instrumentação , Técnicas de Amplificação de Ácido Nucleico/instrumentação , COVID-19/diagnóstico , COVID-19/virologia , RNA Viral/análise , RNA Viral/genética , Técnicas de Diagnóstico Molecular/instrumentação , Técnicas de Diagnóstico Molecular/métodos , Teste de Ácido Nucleico para COVID-19/instrumentação , Teste de Ácido Nucleico para COVID-19/métodos , Kit de Reagentes para Diagnóstico
10.
Small Methods ; 8(8): e2400030, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38716631

RESUMO

High-quality, low-cost, and rapid detection is essential for the society to reopen the economy during the critical period of transition from Coronavirus Disease 2019 (COVID-19) pandemic response to pandemic control. In addition to performing sustainable and target-driven tracking of SARS-CoV-2, conducting comprehensive surveillance of variants and multiple respiratory pathogens is also critical due to the frequency of reinfections, mutation immune escape, and the growing prevalence of the cocirculation of multiple viruses. By utilizing a 0.05 cents wax interface, a Stable Interface assisted Multiplex Pathogenesis Locating Estimation in Onepot (SIMPLEone) using nested RPA and CRISPR/Cas12a enzymatic reporting system is successfully developed. This smartphone-based SIMPLEone system achieves highly sensitive one-pot detection of SARS-CoV-2 and its variants, or multiple respiratory viruses, in 40 min. A total of 89 clinical samples, 14 environmental samples, and 20 cat swab samples are analyzed by SIMPLEone, demonstrating its excellent sensitivity (3-6 copies/reaction for non-extraction detection of swab and 100-150 copies/mL for RNA extraction-based assay), accuracy (>97.7%), and specificity (100%). Furthermore, a high percentage (44.2%) of co-infection cases are detected in SARS-CoV-2-infected patients using SIMPLEone's multiplex detection capability.


Assuntos
COVID-19 , SARS-CoV-2 , Ceras , SARS-CoV-2/genética , SARS-CoV-2/isolamento & purificação , COVID-19/diagnóstico , COVID-19/virologia , Humanos , Ceras/química , Sensibilidade e Especificidade , Animais , Teste de Ácido Nucleico para COVID-19/métodos , Teste de Ácido Nucleico para COVID-19/instrumentação , Gatos , Smartphone , Técnicas de Amplificação de Ácido Nucleico/métodos , RNA Viral/genética , Sistemas CRISPR-Cas , Técnicas de Diagnóstico Molecular/métodos
11.
Anal Methods ; 16(20): 3249-3255, 2024 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-38726641

RESUMO

The past and present scenario of COVID-19 has revealed the necessity of simple point-of-care tests. When combined with the great advantages of amplification, lateral flow assay nucleic acid analysis represents a more sensitive molecular diagnostic technique compared to universal protein analysis. Room temperature operation, an enzyme-free nature, and in situ elongation make hybrid chain reaction amplification (HCR) a good candidate for amplified combined lateral flow assays (LFAs). Since dual modes of detection can not only satisfy different application scenarios, but also reduce the false-negative rate, in this paper, visual and fluorescent detection based on labelling with colloidal gold nanoparticles and fluorescence labelling were incorporated into a HCR integrated with a LFA. The detection assay was finished in 30 minutes. The linear relationship between the signal and the concentration of the characteristic segment in the COVID-19 ORF gene was demonstrated. The obtained detection limits of as low as 10 fM (6.02 × 103 copies per mL) and 1 fM (6.02 × 102 copies per mL), respectively, were comparable with those in the literature. The multi-site HCR amplification integrated with LFA of a 1053 bp nucleic acid chain was also preliminarily studied, and tri-site amplification was found to exhibit higher signal intensity than single-site amplification. This study provides a promising strategy for simple, sensitive, and wide-ranging detection of pathogenic bacteria.


Assuntos
COVID-19 , Técnicas de Amplificação de Ácido Nucleico , SARS-CoV-2 , SARS-CoV-2/genética , Humanos , COVID-19/diagnóstico , Técnicas de Amplificação de Ácido Nucleico/métodos , Limite de Detecção , Técnicas de Diagnóstico Molecular/métodos , Teste de Ácido Nucleico para COVID-19/métodos , Teste de Ácido Nucleico para COVID-19/instrumentação , Nanopartículas Metálicas/química , RNA Viral/análise , RNA Viral/genética
12.
Biosens Bioelectron ; 259: 116375, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-38749283

RESUMO

Since the outbreak of the novel severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) at the end of 2019, the spread of the virus has posed a significant threat to public health and the global economy. This work proposed a one-step, dual-structure-switching aptamer-mediated signal amplification cascade for rapid and sensitive detection of the SARS-CoV-2 nucleocapsid protein. This system consisted of two DNA aptamers with structure-switching functionality and fuel DNA, where a cascade of strand hybridization and displacement triggered fluorescence generation and signal amplification. This aptamer-based amplification cascade required neither an amplification stage using enzymes nor pre-processing steps such as washing, viral isolation, and gene extraction. The assay could distinguish SARS-CoV-2 from other respiratory viruses and detect up to 1.0 PFU/assay of SARS-CoV-2 within 30 min at room temperature. In 35 nasopharyngeal clinical samples, the assay accurately assessed 25 positive and 10 negative clinical swab samples, which were confirmed using quantitative polymerase chain reaction. The strategy reported herein can help detect newly emerging pathogens and biomarkers of various diseases in liquid samples. In addition, the developed detection system consisting of only DNA and fluorophores can be widely integrated into liquid biopsy platforms for disease diagnosis.


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , COVID-19 , Técnicas de Amplificação de Ácido Nucleico , SARS-CoV-2 , SARS-CoV-2/isolamento & purificação , SARS-CoV-2/genética , Humanos , Técnicas Biossensoriais/métodos , Aptâmeros de Nucleotídeos/química , COVID-19/virologia , COVID-19/diagnóstico , Técnicas de Amplificação de Ácido Nucleico/métodos , Proteínas do Nucleocapsídeo de Coronavírus/genética , Fosfoproteínas/química , Limite de Detecção , Teste de Ácido Nucleico para COVID-19/métodos , Teste de Ácido Nucleico para COVID-19/instrumentação
13.
Methods Mol Biol ; 2804: 195-206, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38753149

RESUMO

Clinical diagnostics of infectious diseases via nucleic acid amplification tests (NAATs) depend on a separate step of isolation of nucleic acids from cells/viruses embedded in complex biological matrices. The most recent example has been reverse transcription polymerase chain reaction (RT-PCR) for amplification and detection of SARS-CoV-2 RNA for COVID-19 diagnostics. Kits for RNA extraction and purification are commercially available; however, their integration with amplification systems is generally lacking, resulting in two separate steps, i.e., sample preparation and amplification. This makes NAATs more time-consuming, requiring skilled personnel, and can increase the likelihood of contamination. Here, we describe a setup and methodology to perform the quick extraction and detection of nucleic acids in an integrated manner. In particular, we focus on the use of an immiscible filtration device for capture, isolation, concentration, amplification, and colorimetric detection of SARS-CoV-2 RNA.


Assuntos
COVID-19 , Filtração , Técnicas de Amplificação de Ácido Nucleico , RNA Viral , SARS-CoV-2 , RNA Viral/isolamento & purificação , RNA Viral/análise , RNA Viral/genética , Humanos , SARS-CoV-2/isolamento & purificação , SARS-CoV-2/genética , Técnicas de Amplificação de Ácido Nucleico/métodos , Técnicas de Amplificação de Ácido Nucleico/instrumentação , COVID-19/diagnóstico , COVID-19/virologia , Filtração/instrumentação , Filtração/métodos , Teste de Ácido Nucleico para COVID-19/métodos , Teste de Ácido Nucleico para COVID-19/instrumentação , Colorimetria/métodos , Colorimetria/instrumentação
14.
Diagn Microbiol Infect Dis ; 109(3): 116323, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38703530

RESUMO

PURPOSE: To evaluate the performance of a newly developed 2019-nCoV nucleic acid detection kit based on Ion Proton sequencing platform and make comparation with MGI Tech (DNBSEQ-G99) platform. METHODS: References and clinical samples were used to evaluate the precision, agreement rate, limit of detection (LOD), anti-interference ability and analytical specificity. Twenty-seven clinical specimens were used to make comparison between two platforms. RESULTS: The kit showed good intra-assay, inter-assay, inter-day precision between different operators and laboratories, fine agreement rate with references, a relatively low LOD of 1 × 103 copies/ml, anti-interference capability of 5 % whole blood and 1mg/ml mucin and no cross reaction with twenty-nine common clinical pathogens. Consistency of variant classification was observed between two platforms. The WGS from Ion Proton tended to have higher coverage and less missing data. CONCLUSIONS: The newly developed kit has shown satisfactory performances and excellent consistency with DNBSEQ-G99, making it a good alternative choice clinically.


Assuntos
COVID-19 , SARS-CoV-2 , Sensibilidade e Especificidade , Humanos , SARS-CoV-2/genética , COVID-19/diagnóstico , RNA Viral/genética , Limite de Detecção , Sequenciamento de Nucleotídeos em Larga Escala/métodos , Teste de Ácido Nucleico para COVID-19/métodos , Teste de Ácido Nucleico para COVID-19/instrumentação , Kit de Reagentes para Diagnóstico/normas
15.
Diagn Microbiol Infect Dis ; 109(3): 116297, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38604076

RESUMO

The LAMPdirect Genelyzer KIT allows for the detection of SARS-CoV-2 RNA in saliva samples with a loop-mediated isothermal amplification (LAMP) method and generates results within 20 min. It has been approved by the Pharmaceuticals and Medical Devices Agency in Japan. In this study, the performance of the LAMPdirect Genelyzer KIT was compared with that of the RT-qPCR reference method using 50 nasopharyngeal swabs and 100 saliva samples. In addition, we evaluated the applicability of an alternative reverse transcriptase and the effects of an inactivation buffer. The total agreement rates were 80.0 % and 82.0 % for nasopharyngeal and saliva samples, respectively. When considering samples at the detection limit (50 copies/reaction) that increases the chance of transmission between humans, the total agreement rates were 100% and 94.1% for nasopharyngeal and saliva samples, respectively. The LAMP method is simple, fast, and inexpensive, making it useful for small medical institutions or rural areas.


Assuntos
COVID-19 , Técnicas de Diagnóstico Molecular , Nasofaringe , Técnicas de Amplificação de Ácido Nucleico , RNA Viral , SARS-CoV-2 , Saliva , Humanos , Saliva/virologia , SARS-CoV-2/genética , SARS-CoV-2/isolamento & purificação , Nasofaringe/virologia , Técnicas de Amplificação de Ácido Nucleico/métodos , RNA Viral/genética , RNA Viral/isolamento & purificação , COVID-19/diagnóstico , COVID-19/virologia , Técnicas de Diagnóstico Molecular/métodos , Sensibilidade e Especificidade , Kit de Reagentes para Diagnóstico/normas , Teste de Ácido Nucleico para COVID-19/métodos , Teste de Ácido Nucleico para COVID-19/instrumentação , Manejo de Espécimes/métodos
16.
Diagn Microbiol Infect Dis ; 109(3): 116325, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38688146

RESUMO

Following the relaxation of COVID-19 restrictions, other respiratory viruses such as influenza and respiratory syncytial virus (RSV), whose transmission were decreased due to COVID-19 precautions, are rising again. Because of similar clinical features and reported co-infections, multiplex detection of SARS-CoV-2, influenza A/B, and RSV is required to use specific treatments. This study assessed an extraction-free sample preparation (heat treatment at 95°C for 3 minutes) for multiplex detection using rRT-PCR. Despite an observed Ct-delay (∆Ct) averageing 1.26 compared to the standard method, an acceptable total sensitivity of 92 % and a negative predictive value (NPV) of 96 % were obtained. Moreover, Implementation on a microfluidic chip demonstrated efficiency, maintaining an excellent correlation (R2=0.983) with the standard method. Combining this extraction-free procedure with rRT-PCR on a microfluidic chip seems promising, because it simplifies the design and reduces the cost and complexity of the integrated assay for multiplex detection of SARS-CoV-2, influenza A/B, and RSV.


Assuntos
COVID-19 , Vírus da Influenza A , Vírus da Influenza B , Influenza Humana , Infecções por Vírus Respiratório Sincicial , SARS-CoV-2 , Humanos , COVID-19/diagnóstico , SARS-CoV-2/isolamento & purificação , SARS-CoV-2/genética , Influenza Humana/diagnóstico , Influenza Humana/virologia , Vírus da Influenza A/isolamento & purificação , Vírus da Influenza A/genética , Vírus da Influenza B/isolamento & purificação , Vírus da Influenza B/genética , Infecções por Vírus Respiratório Sincicial/diagnóstico , Infecções por Vírus Respiratório Sincicial/virologia , Sensibilidade e Especificidade , Dispositivos Lab-On-A-Chip , Reação em Cadeia da Polimerase Multiplex/métodos , Vírus Sinciciais Respiratórios/isolamento & purificação , Vírus Sinciciais Respiratórios/genética , Coinfecção/virologia , Coinfecção/diagnóstico , Teste de Ácido Nucleico para COVID-19/métodos , Teste de Ácido Nucleico para COVID-19/instrumentação
17.
Biosens Bioelectron ; 257: 116292, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38653014

RESUMO

We report the development and initial validation of a paper-based nucleic acid testing platform that integrates Loop-mediated isothermal amplification (LAMP) with clustered regularly interspaced short palindromic repeats (CRISPR) technology, referred to as PLACID (Paper-based LAMP-CRISPR Integrated Diagnostics). LAMP eliminates the need for thermal cycling, resulting in simplified instrumentation, and the CRISPR-associated protein (Cas 12a) system eliminates false positive signals from LAMP products, resulting in highly selective and sensitive assays. We optimized the assay to perform both amplification and detection entirely on paper, eliminating the need for complex fluid handling steps and lateral flow assay transfers. Additionally, we engineered a smartphone-operated system that includes a low-powered, non-contact IR heating chamber to actuate paper-based LAMP and CRISPR reactions and enable the detection of fluorescent signals from the paper. The platform demonstrates high specificity and sensitivity in detecting nucleic acid targets with a limit of detection of 50 copies/µL. We integrate an equipment-free sample preparation separation technology designed to streamline the preparation of crude samples prior to nucleic acid testing. The practical utility of our platform is demonstrated by the successful detection of spiked SARS-CoV-2 RNA fragments in saliva, E. Coli in soil, and pathogenic E. Coli in clinically fecal samples of infected patients. Furthermore, we demonstrate that the paper-based LAMP CRISPR chips employed in our assays possess a shelf life of several weeks, establishing them as viable candidates for on-site diagnostics.


Assuntos
Técnicas Biossensoriais , COVID-19 , Sistemas CRISPR-Cas , Técnicas de Diagnóstico Molecular , Técnicas de Amplificação de Ácido Nucleico , Papel , SARS-CoV-2 , Técnicas de Amplificação de Ácido Nucleico/métodos , Técnicas de Amplificação de Ácido Nucleico/instrumentação , Humanos , Técnicas Biossensoriais/métodos , SARS-CoV-2/genética , SARS-CoV-2/isolamento & purificação , COVID-19/diagnóstico , COVID-19/virologia , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Diagnóstico Molecular/instrumentação , Sistemas CRISPR-Cas/genética , Limite de Detecção , Repetições Palindrômicas Curtas Agrupadas e Regularmente Espaçadas/genética , Desenho de Equipamento , Teste de Ácido Nucleico para COVID-19/métodos , Teste de Ácido Nucleico para COVID-19/instrumentação , Escherichia coli/genética , Escherichia coli/isolamento & purificação , Proteínas Associadas a CRISPR/genética , Smartphone
18.
J Appl Lab Med ; 9(4): 716-727, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38507614

RESUMO

BACKGROUND: During the COVID-19 pandemic, many molecular diagnostic laboratories performed high-throughput SARS-CoV-2 testing often with implementation of automated workflows. In parallel, vaccination campaigns resulted increasingly in specimens from fully vaccinated patients, with resultant clinical inquiries regarding positive results in this patient population. This prompted a quality improvement initiative to investigate the semi-automated testing workflow for false-positive results. The troubleshooting workflow is described and procedural improvements are outlined that serve as a resource for other molecular diagnostic laboratories that need to overcome testing anomalies in a semi-automated environment. METHODS: This workflow utilized the MagMax-96 Viral RNA kit and the CDC 2019-nCoV RT-qPCR Panel on the Agilent Bravo Liquid-Handler (Bravo). Screening of the environment, personnel, and the mechanical performance of instrumentation using low Ct checkerboard challenges was executed to identify sources of cross-contamination. Evaluation of the assay and reporting design was conducted. RESULTS: Specimen contamination was observed during the viral extraction process on the Bravo. Changes to the program reduced plate contamination by 50% and importantly revealed consistent hallmarks of contaminated samples. We adjusted the reporting algorithm using these indicators of false positives. False positives that were identified made up 0.11% of the 45 000+ tests conducted over the following 8 months. CONCLUSIONS: These adjustments provided confident and quality results while maintaining turnaround time for patients and pandemic-related public health initiatives. This corrected false-positive rate is concordant with previously published studies from diagnostic laboratories utilizing automated systems and may be considered a laboratory performance standard for this type of testing.


Assuntos
Automação Laboratorial , COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/isolamento & purificação , SARS-CoV-2/genética , COVID-19/diagnóstico , COVID-19/virologia , Reações Falso-Positivas , Teste de Ácido Nucleico para COVID-19/métodos , Teste de Ácido Nucleico para COVID-19/instrumentação , Fluxo de Trabalho , RNA Viral/isolamento & purificação , RNA Viral/análise , RNA Viral/genética , Teste para COVID-19/métodos
19.
Sci Rep ; 12(1): 3951, 2022 03 10.
Artigo em Inglês | MEDLINE | ID: mdl-35273232

RESUMO

The SARS-CoV-2 pandemic has brought to light the need for expedient diagnostic testing. Cost and availability of large-scale testing capacity has led to a lag in turnaround time and hindered contact tracing efforts, resulting in a further spread of SARS-CoV-2. To increase the speed and frequency of testing, we developed a cost-effective single-tube approach for collection, denaturation, and analysis of clinical samples. The approach utilizes 1 µL microbiological inoculation loops to collect saliva, sodium dodecyl sulfate (SDS) to inactivate and release viral genomic RNA, and a diagnostic reaction mix containing polysorbate 80 (Tween 80). In the same tube, the SDS-denatured clinical samples are introduced to the mixtures containing all components for nucleic acids detection and Tween 80 micelles to absorb the SDS and allow enzymatic reactions to proceed, obviating the need for further handling of the samples. The samples can be collected by the tested individuals, further decreasing the need for trained personnel to administer the test. We validated this single-tube sample-to-assay method with reverse transcription quantitative real-time polymerase chain reaction (RT-qPCR) and reverse transcription loop-mediated isothermal amplification (RT-LAMP) and discovered little-to-no difference between Tween- and SDS-containing reaction mixtures, compared to control reactions. This approach reduces the logistical burden of traditional large-scale testing and provides a method of deployable point-of-care diagnostics to increase testing frequency.


Assuntos
Teste de Ácido Nucleico para COVID-19/métodos , SARS-CoV-2/genética , Saliva/virologia , Teste de Ácido Nucleico para COVID-19/instrumentação , Humanos , Técnicas de Diagnóstico Molecular , Técnicas de Amplificação de Ácido Nucleico , Reação em Cadeia da Polimerase em Tempo Real , Manejo de Espécimes/instrumentação , Manejo de Espécimes/métodos
20.
Sci Rep ; 12(1): 3775, 2022 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-35260588

RESUMO

Loop-mediated isothermal amplification is known for its high sensitivity, specificity and tolerance to inhibiting-substances. In this work, we developed a device for performing real-time colorimetric LAMP combining the accuracy of lab-based quantitative analysis with the simplicity of point-of-care testing. The device innovation lies on the use of a plastic tube anchored vertically on a hot surface while the side walls are exposed to a mini camera able to take snapshots of the colour change in real time during LAMP amplification. Competitive features are the rapid analysis (< 30 min), quantification over 9 log-units, crude sample-compatibility (saliva, tissue, swabs), low detection limit (< 5 copies/reaction), smartphone-operation, fast prototyping (3D-printing) and ability to select the dye of interest (Phenol red, HNB). The device's clinical utility is demonstrated in cancer mutations-analysis during the detection of 0.01% of BRAF-V600E-to-wild-type molecules from tissue samples and COVID-19 testing with 97% (Ct < 36.8) and 98% (Ct < 30) sensitivity when using extracted RNA and nasopharyngeal-swabs, respectively. The device high technology-readiness-level makes it a suitable platform for performing any colorimetric LAMP assay; moreover, its simple and inexpensive fabrication holds promise for fast deployment and application in global diagnostics.


Assuntos
Teste de Ácido Nucleico para COVID-19/métodos , COVID-19/diagnóstico , COVID-19/virologia , Teste de Ácido Nucleico para COVID-19/instrumentação , Colorimetria , Humanos , Limite de Detecção , Técnicas de Diagnóstico Molecular , Nasofaringe/virologia , Neoplasias/diagnóstico , Neoplasias/genética , Neoplasias/patologia , Técnicas de Amplificação de Ácido Nucleico , Testes Imediatos , Proteínas Proto-Oncogênicas B-raf/genética , RNA Viral/análise , RNA Viral/metabolismo , SARS-CoV-2/genética , SARS-CoV-2/isolamento & purificação , Sensibilidade e Especificidade , Smartphone
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA