Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Ci. Rural ; 39(4)2009.
Artigo em Português | VETINDEX | ID: vti-706285

Resumo

Prospective study was made performing Doppler ultrasonographic exams of fifty kidneys belonging to Persian adult cats. The animals were classified as healthy by laboratorial exams and measurement of arterial systolic pressure. Maximal systolic blood flow velocity (VPS), minimal diastolic blood flow velocity (VDF) and resistivity index (IR) of renal arteries (AR) and aorta (AO) of each animal were evaluated. The results are: left renal artery VPS 40.96±9.08cm s-1 and IR 0.55±0.07; right artery VPS 41.39±9.89cm s-1 and IR 0.52±0.07. It was not observed any statistical significant difference among the sides. Considering both renal arteries it was calculated VPS 41.17±9.40cm s-1 and IR 0.53±0.07. Renal arterial diameter was 0.15±0.02cm. The aorta VPS obtained was 53.17±13.46cm s-1 and the diameter was 0.38±0.04cm. Correlation velocities of renal artery and aorta resuled in a relation 0.38 as minimal and 1.52 as maximal, with 0.82±0.30.


Foi realizado um estudo prospectivo com 50 unidades renais de gatos adultos jovens da raça persa, as quais foram examinadas ao ultrassom Doppler. Os animais foram selecionados como sadios por meio de exames laboratoriais e de pressão arterial sistólica. Foram mensurados os seguintes parâmetros: a velocidade de pico sistólico máximo (VPS), a velocidade diastólica mínima (VDF) e os índices de resistividade (IR) das artérias renais (AR) e da aorta (AO). Para a AR esquerda, foram obtidos VPS 40,96±9,08cm s-1 e IR 0,55±0,07 e, para a AR direita, VPS 41,39±9,89cm s-1 e IR 0,52±0,07. Não foi observada diferença estatisticamente significante entre os lados. Assim, ao serem consideradas ambas as AR, obteve-se a média de VPS 41,17±9,40cm s-1 e IR 0,53±0,07. A média do diâmetro da AR foi de 0,15±0,02cm. Para a aorta, obteve-se VPS 53,17±13,46cm s-1 e média de diâmetro de 0,38±0,04cm. Correlacionando-se os valores de VPS da AR e da AO, obteve-se um índice mínimo de 0,38 e máximo de 1,52, com média de 0,82±0,30.

2.
Ci. Rural ; 39(5)2009.
Artigo em Inglês | VETINDEX | ID: vti-706274

Resumo

The objective of this research was to verify if the study of portal hemodynamic parameters through duplex Doppler ultrasonography (DUS) is able to help to detect portosystemic shunt (PSS) and the shunted vessel origin. It was detected PSS in 20 dogs by abdominal DUS and confirmed at surgery or necropsy from March of 2004 until March 2007. Main ultrasonographic findings were: identification of a tortuous vessel shunting portal flow being: portocaval shunt (16/20 or 80%), esplenocaval shunt (2/20 or 10%), gastrocaval shunt (1/20 or 5%), portoazigo shunt (1/20 or 5%); 2) elevated portal flow velocity before shunt (17/20 or 81%), 3) lower portal flow velocity after shunt (17/20 or 81%), 4) turbulence in the caudal vena cava (10/20 or 47,5%) and 5) reduced liver size (15/20 or 71%). The others ultrasonographic findings associated with clinical records were similar to that described in literature. With this work we could conclude that hemodynamic assessment of portal vein with DUS may be a useful tool for PSS diagnosis and to detect the shunted vessel origin.


O objetivo desta pesquisa foi verificar se o estudo dos parâmetros hemodinâmicos, por meio da ultrassonografia duplex Doppler (USD), é capaz de auxiliar na detecção do desvio portossistêmico (DPS) e na origem do vaso desviado. Por meio da USD abdominal, foram detectados, no período de março de 2004 a março de 2007, casos de DPS em 20 cães, os quais foram confirmados pela cirurgia ou necropsia. Os principais achados ultrassonográficos foram: 1) identificação de um vaso tortuoso, desviando o fluxo portal, sendo: desvio portocaval (16/20 ou 80%), desvio esplenocaval (2/20 ou 10%), desvio gastrocaval (1/20 ou 5%), desvio portoázigos (1/20 ou 5%); 2) velocidade de fluxo portal elevada antes do desvio (17/20 ou 81%); 3) velocidade de fluxo portal diminuída após o desvio (17/20 ou 81%); 4) fluxo turbulento na veia cava caudal (10/20 ou 47,5%); e 5) fígado de tamanho diminuído (15/20 ou 71%). Os outros achados ultrassonográficos associados com dados clínicos foram semelhantes aos descritos na literatura. Com este trabalho, pode-se concluir que a avaliação hemodinâmica da veia portal com USD pode ser uma ferramenta diagnóstica útil na detecção do DPS e na origem do vaso desviado.

3.
Ci. Rural ; 39(5)2009.
Artigo em Inglês | VETINDEX | ID: vti-705961

Resumo

The objective of this research was to verify if the study of portal hemodynamic parameters through duplex Doppler ultrasonography (DUS) is able to help to detect portosystemic shunt (PSS) and the shunted vessel origin. It was detected PSS in 20 dogs by abdominal DUS and confirmed at surgery or necropsy from March of 2004 until March 2007. Main ultrasonographic findings were: identification of a tortuous vessel shunting portal flow being: portocaval shunt (16/20 or 80%), esplenocaval shunt (2/20 or 10%), gastrocaval shunt (1/20 or 5%), portoazigo shunt (1/20 or 5%); 2) elevated portal flow velocity before shunt (17/20 or 81%), 3) lower portal flow velocity after shunt (17/20 or 81%), 4) turbulence in the caudal vena cava (10/20 or 47,5%) and 5) reduced liver size (15/20 or 71%). The others ultrasonographic findings associated with clinical records were similar to that described in literature. With this work we could conclude that hemodynamic assessment of portal vein with DUS may be a useful tool for PSS diagnosis and to detect the shunted vessel origin.


O objetivo desta pesquisa foi verificar se o estudo dos parâmetros hemodinâmicos, por meio da ultrassonografia duplex Doppler (USD), é capaz de auxiliar na detecção do desvio portossistêmico (DPS) e na origem do vaso desviado. Por meio da USD abdominal, foram detectados, no período de março de 2004 a março de 2007, casos de DPS em 20 cães, os quais foram confirmados pela cirurgia ou necropsia. Os principais achados ultrassonográficos foram: 1) identificação de um vaso tortuoso, desviando o fluxo portal, sendo: desvio portocaval (16/20 ou 80%), desvio esplenocaval (2/20 ou 10%), desvio gastrocaval (1/20 ou 5%), desvio portoázigos (1/20 ou 5%); 2) velocidade de fluxo portal elevada antes do desvio (17/20 ou 81%); 3) velocidade de fluxo portal diminuída após o desvio (17/20 ou 81%); 4) fluxo turbulento na veia cava caudal (10/20 ou 47,5%); e 5) fígado de tamanho diminuído (15/20 ou 71%). Os outros achados ultrassonográficos associados com dados clínicos foram semelhantes aos descritos na literatura. Com este trabalho, pode-se concluir que a avaliação hemodinâmica da veia portal com USD pode ser uma ferramenta diagnóstica útil na detecção do DPS e na origem do vaso desviado.

4.
Ci. Rural ; 39(4)2009.
Artigo em Português | VETINDEX | ID: vti-705910

Resumo

Prospective study was made performing Doppler ultrasonographic exams of fifty kidneys belonging to Persian adult cats. The animals were classified as healthy by laboratorial exams and measurement of arterial systolic pressure. Maximal systolic blood flow velocity (VPS), minimal diastolic blood flow velocity (VDF) and resistivity index (IR) of renal arteries (AR) and aorta (AO) of each animal were evaluated. The results are: left renal artery VPS 40.96±9.08cm s-1 and IR 0.55±0.07; right artery VPS 41.39±9.89cm s-1 and IR 0.52±0.07. It was not observed any statistical significant difference among the sides. Considering both renal arteries it was calculated VPS 41.17±9.40cm s-1 and IR 0.53±0.07. Renal arterial diameter was 0.15±0.02cm. The aorta VPS obtained was 53.17±13.46cm s-1 and the diameter was 0.38±0.04cm. Correlation velocities of renal artery and aorta resuled in a relation 0.38 as minimal and 1.52 as maximal, with 0.82±0.30.


Foi realizado um estudo prospectivo com 50 unidades renais de gatos adultos jovens da raça persa, as quais foram examinadas ao ultrassom Doppler. Os animais foram selecionados como sadios por meio de exames laboratoriais e de pressão arterial sistólica. Foram mensurados os seguintes parâmetros: a velocidade de pico sistólico máximo (VPS), a velocidade diastólica mínima (VDF) e os índices de resistividade (IR) das artérias renais (AR) e da aorta (AO). Para a AR esquerda, foram obtidos VPS 40,96±9,08cm s-1 e IR 0,55±0,07 e, para a AR direita, VPS 41,39±9,89cm s-1 e IR 0,52±0,07. Não foi observada diferença estatisticamente significante entre os lados. Assim, ao serem consideradas ambas as AR, obteve-se a média de VPS 41,17±9,40cm s-1 e IR 0,53±0,07. A média do diâmetro da AR foi de 0,15±0,02cm. Para a aorta, obteve-se VPS 53,17±13,46cm s-1 e média de diâmetro de 0,38±0,04cm. Correlacionando-se os valores de VPS da AR e da AO, obteve-se um índice mínimo de 0,38 e máximo de 1,52, com média de 0,82±0,30.

5.
Artigo em Português | LILACS-Express | VETINDEX | ID: biblio-1477580

Resumo

Prospective study was made performing Doppler ultrasonographic exams of fifty kidneys belonging to Persian adult cats. The animals were classified as healthy by laboratorial exams and measurement of arterial systolic pressure. Maximal systolic blood flow velocity (VPS), minimal diastolic blood flow velocity (VDF) and resistivity index (IR) of renal arteries (AR) and aorta (AO) of each animal were evaluated. The results are: left renal artery VPS 40.96±9.08cm s-1 and IR 0.55±0.07; right artery VPS 41.39±9.89cm s-1 and IR 0.52±0.07. It was not observed any statistical significant difference among the sides. Considering both renal arteries it was calculated VPS 41.17±9.40cm s-1 and IR 0.53±0.07. Renal arterial diameter was 0.15±0.02cm. The aorta VPS obtained was 53.17±13.46cm s-1 and the diameter was 0.38±0.04cm. Correlation velocities of renal artery and aorta resuled in a relation 0.38 as minimal and 1.52 as maximal, with 0.82±0.30.


Foi realizado um estudo prospectivo com 50 unidades renais de gatos adultos jovens da raça persa, as quais foram examinadas ao ultrassom Doppler. Os animais foram selecionados como sadios por meio de exames laboratoriais e de pressão arterial sistólica. Foram mensurados os seguintes parâmetros: a velocidade de pico sistólico máximo (VPS), a velocidade diastólica mínima (VDF) e os índices de resistividade (IR) das artérias renais (AR) e da aorta (AO). Para a AR esquerda, foram obtidos VPS 40,96±9,08cm s-1 e IR 0,55±0,07 e, para a AR direita, VPS 41,39±9,89cm s-1 e IR 0,52±0,07. Não foi observada diferença estatisticamente significante entre os lados. Assim, ao serem consideradas ambas as AR, obteve-se a média de VPS 41,17±9,40cm s-1 e IR 0,53±0,07. A média do diâmetro da AR foi de 0,15±0,02cm. Para a aorta, obteve-se VPS 53,17±13,46cm s-1 e média de diâmetro de 0,38±0,04cm. Correlacionando-se os valores de VPS da AR e da AO, obteve-se um índice mínimo de 0,38 e máximo de 1,52, com média de 0,82±0,30.

6.
Artigo em Inglês | LILACS-Express | VETINDEX | ID: biblio-1477632

Resumo

The objective of this research was to verify if the study of portal hemodynamic parameters through duplex Doppler ultrasonography (DUS) is able to help to detect portosystemic shunt (PSS) and the shunted vessel origin. It was detected PSS in 20 dogs by abdominal DUS and confirmed at surgery or necropsy from March of 2004 until March 2007. Main ultrasonographic findings were: identification of a tortuous vessel shunting portal flow being: portocaval shunt (16/20 or 80%), esplenocaval shunt (2/20 or 10%), gastrocaval shunt (1/20 or 5%), portoazigo shunt (1/20 or 5%); 2) elevated portal flow velocity before shunt (17/20 or 81%), 3) lower portal flow velocity after shunt (17/20 or 81%), 4) turbulence in the caudal vena cava (10/20 or 47,5%) and 5) reduced liver size (15/20 or 71%). The others ultrasonographic findings associated with clinical records were similar to that described in literature. With this work we could conclude that hemodynamic assessment of portal vein with DUS may be a useful tool for PSS diagnosis and to detect the shunted vessel origin.


O objetivo desta pesquisa foi verificar se o estudo dos parâmetros hemodinâmicos, por meio da ultrassonografia duplex Doppler (USD), é capaz de auxiliar na detecção do desvio portossistêmico (DPS) e na origem do vaso desviado. Por meio da USD abdominal, foram detectados, no período de março de 2004 a março de 2007, casos de DPS em 20 cães, os quais foram confirmados pela cirurgia ou necropsia. Os principais achados ultrassonográficos foram: 1) identificação de um vaso tortuoso, desviando o fluxo portal, sendo: desvio portocaval (16/20 ou 80%), desvio esplenocaval (2/20 ou 10%), desvio gastrocaval (1/20 ou 5%), desvio portoázigos (1/20 ou 5%); 2) velocidade de fluxo portal elevada antes do desvio (17/20 ou 81%); 3) velocidade de fluxo portal diminuída após o desvio (17/20 ou 81%); 4) fluxo turbulento na veia cava caudal (10/20 ou 47,5%); e 5) fígado de tamanho diminuído (15/20 ou 71%). Os outros achados ultrassonográficos associados com dados clínicos foram semelhantes aos descritos na literatura. Com este trabalho, pode-se concluir que a avaliação hemodinâmica da veia portal com USD pode ser uma ferramenta diagnóstica útil na detecção do DPS e na origem do vaso desviado.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA