Resumo
The cardiopulmonary and acid-base effects of butorphanol in desflurane anesthetized dogs breathing spontaneously were evaluated. Twenty adult healthy, male and female dogs were used. They were separated into two groups of 10 animals each (GS and GB). Anesthesia was induced with propofol (8.4±0.8mg kg-1 IV) and maintained with desflurane (10V%). After 40 minutes of induction, the animals from GS received saline solution at 0.9% (0.05mL kg-1) and from GB received butorphanol (0.4mg kg-1), both applied intramuscularly. Heart (HR) and respiratory (RR) rates; systolic (SAP), diastolic (DAP) and mean (MAP) arterial pressures; arterial blood pH (pH), arterial partial pressure of O2 (PaO2) and arterial partial pressure of CO2 (PaCO2); base deficit (BD), arterial oxygen saturation (SaO2) and bicarbonate ion concentration (HCO3) were measured. The measurements were taken immediately before the application of the agents (M0). Serial measurements were carried out at 15 minutes intervals after the administration of butorphanol or saline up to 75 minutes (M15, M30, M45, M60 and M75). Data were submitted to Profile Analysis (P 0.05). After butorphanol administration HR, SAP, DAP and MAP decreased significantly. PaO2 had discreet alterations, however without clinical meaning. RR and pH decreased after butorphanol administration while PaCO2 increased significantly. It was possible to conclude that butorphanol administration in desflurane anesthetized dogs produced reduction in the averages of heart rate and arterial pressure and relatively to the respiratory parameters, the opioid produced hypoventilation in spontaneously breathing dogs.
Este experimento teve por objetivos avaliar as possíveis alterações cardiopulmonares e hemogasométricas decorrentes do uso do butorfanol em cães submetidos à anestesia pelo desfluorano sob ventilação espontânea. Para tal, foram utilizados vinte cães adultos, clinicamente saudáveis, pesando 12±3kg. Os animais foram distribuídos igualmente em dois grupos, GS e GB, e induzidos à anestesia com propofol (8,4±0,8mg kg-1, IV), intubados e submetidos à anestesia inalatória pelo desfluorano (10V%). Decorridos 40 minutos da indução, foi administrado aos animais do GS 0,05mL kg-1 de solução fisiológica a 0,9% (salina), enquanto que, no GB, foi aplicado butorfanol na dose de 0,4mg kg-1, ambos pela via intramuscular. As observações das variáveis freqüências cardíaca (FC) e respiratória (f), pressões arteriais sistólica (PAS), diastólica (PAD) e média (PAM), pH arterial (pH), pressão parcial de oxigênio no sangue arterial (PaO2), pressão parcial de dióxido de carbono no sangue arterial (PaCO2), déficit de base (DB), bicarbonato (HCO3) e saturação de oxigênio na hemoglobina (SatO2) tiveram início imediatamente antes da aplicação do opióide ou salina (M0). Novas mensurações foram realizadas 15 minutos após a administração do butorfanol ou salina (M15) e as demais colheitas foram realizadas a intervalos de 15 minutos, por um período de 60 minutos (M30, M45, M60 e M75). Os dados numéricos dessas variáveis foram submetidos à Análise de Perfil (P 0,05). A freqüência cardíaca apresentou alteração no GB, com média de M0 maior que as demais. As PAS, PAD e PAM, assim como a f e o pH, apresentaram valores menores após a administração do opióide no GB, em comparação ao GS. A PaO2 apresentou discretas alterações, entretanto sem significado clínico, enquanto que a PaCO2 e o DB apresentaram valores de M0 menores que os demais após a aplicação do butorfanol. Os resultados obtidos permitem concluir que a administração do butorfanol em cães submetidos à anestesia pelo desfluorano, sob ventilação espontânea, reduz a freqüência cardíaca e a pressão arterial e promove certo grau de hipoventilação.
Resumo
The cardiopulmonary and acid-base effects of butorphanol in desflurane anesthetized dogs breathing spontaneously were evaluated. Twenty adult healthy, male and female dogs were used. They were separated into two groups of 10 animals each (GS and GB). Anesthesia was induced with propofol (8.4±0.8mg kg-1 IV) and maintained with desflurane (10V%). After 40 minutes of induction, the animals from GS received saline solution at 0.9% (0.05mL kg-1) and from GB received butorphanol (0.4mg kg-1), both applied intramuscularly. Heart (HR) and respiratory (RR) rates; systolic (SAP), diastolic (DAP) and mean (MAP) arterial pressures; arterial blood pH (pH), arterial partial pressure of O2 (PaO2) and arterial partial pressure of CO2 (PaCO2); base deficit (BD), arterial oxygen saturation (SaO2) and bicarbonate ion concentration (HCO3) were measured. The measurements were taken immediately before the application of the agents (M0). Serial measurements were carried out at 15 minutes intervals after the administration of butorphanol or saline up to 75 minutes (M15, M30, M45, M60 and M75). Data were submitted to Profile Analysis (P 0.05). After butorphanol administration HR, SAP, DAP and MAP decreased significantly. PaO2 had discreet alterations, however without clinical meaning. RR and pH decreased after butorphanol administration while PaCO2 increased significantly. It was possible to conclude that butorphanol administration in desflurane anesthetized dogs produced reduction in the averages of heart rate and arterial pressure and relatively to the respiratory parameters, the opioid produced hypoventilation in spontaneously breathing dogs.
Este experimento teve por objetivos avaliar as possíveis alterações cardiopulmonares e hemogasométricas decorrentes do uso do butorfanol em cães submetidos à anestesia pelo desfluorano sob ventilação espontânea. Para tal, foram utilizados vinte cães adultos, clinicamente saudáveis, pesando 12±3kg. Os animais foram distribuídos igualmente em dois grupos, GS e GB, e induzidos à anestesia com propofol (8,4±0,8mg kg-1, IV), intubados e submetidos à anestesia inalatória pelo desfluorano (10V%). Decorridos 40 minutos da indução, foi administrado aos animais do GS 0,05mL kg-1 de solução fisiológica a 0,9% (salina), enquanto que, no GB, foi aplicado butorfanol na dose de 0,4mg kg-1, ambos pela via intramuscular. As observações das variáveis freqüências cardíaca (FC) e respiratória (f), pressões arteriais sistólica (PAS), diastólica (PAD) e média (PAM), pH arterial (pH), pressão parcial de oxigênio no sangue arterial (PaO2), pressão parcial de dióxido de carbono no sangue arterial (PaCO2), déficit de base (DB), bicarbonato (HCO3) e saturação de oxigênio na hemoglobina (SatO2) tiveram início imediatamente antes da aplicação do opióide ou salina (M0). Novas mensurações foram realizadas 15 minutos após a administração do butorfanol ou salina (M15) e as demais colheitas foram realizadas a intervalos de 15 minutos, por um período de 60 minutos (M30, M45, M60 e M75). Os dados numéricos dessas variáveis foram submetidos à Análise de Perfil (P 0,05). A freqüência cardíaca apresentou alteração no GB, com média de M0 maior que as demais. As PAS, PAD e PAM, assim como a f e o pH, apresentaram valores menores após a administração do opióide no GB, em comparação ao GS. A PaO2 apresentou discretas alterações, entretanto sem significado clínico, enquanto que a PaCO2 e o DB apresentaram valores de M0 menores que os demais após a aplicação do butorfanol. Os resultados obtidos permitem concluir que a administração do butorfanol em cães submetidos à anestesia pelo desfluorano, sob ventilação espontânea, reduz a freqüência cardíaca e a pressão arterial e promove certo grau de hipoventilação.
Resumo
The aim of this article was to establish the correlation between different rates of continuous infusion of propofol and the alterations that might occur with the physiologic parameters most commonly measured by the anesthesiologists. Twenty four adult dogs were randomly divided into 3 groups (P2, P4, P8). All the animals were induced with propofol (10mg/kg), followed immediately by the continuous infusion of the agent: 0.2mg/kg/min (P2), 0.4mg/kg/min (P4) and 0.8mg/kg/min (P8). The heart rate (HR), systolic, diastolic and mean arterial pressures (SAP, DAP and MAP), electrocardiography (ECG), respiratory rate (RR), and body temperature (T) were measured before any drug administration (M0) and 10, 20, 30, 40 and 50 minutes after the start of the continuous infusion of propofol. The numerical data were submitted to Profile of Variance followed by F Test (P 0.05). The HR showed differences among groups at M20 (P2: 91 ± 14,92; P4: 113 ± 17,18; P8: 120 ± 14,84), M30 (P2: 89 ± 13,79; P4: 110 ± 14,3; P8: 114 ± 10,89), and M40 (P2: 88 ± 17,3; P4: 103 ± 16; P8: 109 ± 8,2), wich could be justified because P2 demonstrated minor reduction of MAP. There is no need of HR increasing to establish the cardiac output, and consequently, to maintain the AP. A reduction in SAP about 26,9% to P2, 23,6% to P4 and 30,6% to P8, in PAP about 36,2% to P2; 38,1 to P4 and 52,7% to P8I; and in MAP about 32% to P2, 26,3% to P4 and 38,4% to P8 were observed. These reductions could be related to the decrease of peripheral vascular resistance. It was possible to conclude that the decrease observed in SAP, DAP, MAP and RR are dependent on the infusion rate of propofol, which also caused reduction of the rectal temperature in the 3 groups.
A fim de determinar possíveis alterações nos principais parâmetros fisiológicos determinados pela infusão contínua de propofol, em diferentes doses, foram utilizados 24 cães adultos distribuídos aleatoriamente em 3 grupos (P2, P4 e P8). Os animais foram induzidos à anestesia pela administração intravenosa de propofol (10mg/kg) e, ato contínuo, os cães receberam o anestésico, em infusão contínua nas doses de 0,2mg/kg/min (P2), 0,4mg/kg/min (P4) e 0,8mg/kg/min (P8). As mensurações dos valores das variáveis cardiorrespiratórias [freqüência cardíaca (FC); pressões arteriais sistólica, diastólica e média (PAS, PAD e PAM, respectivamente); eletrocardiografia e freqüência respiratória (f)] e temperatura retal (T) foram realizadas antes da aplicação do fármaco (M0) e após 10, 20, 30, 40 e 50 minutos do início da infusão contínua. Os dados numéricos das variáveis estudadas foram submetidos à Análise de Variância (ANOVA) seguida pelo Teste F (P 0,05). Para FC, observaram-se diferenças entre os grupos no M20 (P2: 91 ± 14,92; P4: 113 ± 17,18; P8: 120 ± 14,84), M30 (P2: 89 ± 13,79; P4: 110 ± 14,3; P8: 114 ± 10,89) e em M40 (P2: 88 ± 17,3; P4: 103 ± 16; P8: 109 ± 8,2), que podem ser justificadas por P2 apresentar menor redução da PAM, não havendo a necessidade de aumento da FC para estabilizar o débito cardíaco e consequentemente para manter a PA. A PAS registrou redução de 26,9% para P2, 23,6% para P4 e 30,6% para P8. Para PAD foram observados decréscimos de 36,2% para P2; 38,1 para P4 e 52,7% para P8, enquanto para PAM a diminuição foi de 32% para P2, 26,3% para P4 e 38,4% para P8. Essas reduções poderiam ser ocasionadas pela diminuição da resistência periférica vascular. Concluiu-se que as reduções ocorridas na PAS, PAD, PAM e f são dependentes da dose de infusão do fármaco, que também proporcionou discreta redução na temperatura retal nos três grupos.
Resumo
The aim of this article was to establish the correlation between different rates of continuous infusion of propofol and the alterations that might occur with the physiologic parameters most commonly measured by the anesthesiologists. Twenty four adult dogs were randomly divided into 3 groups (P2, P4, P8). All the animals were induced with propofol (10mg/kg), followed immediately by the continuous infusion of the agent: 0.2mg/kg/min (P2), 0.4mg/kg/min (P4) and 0.8mg/kg/min (P8). The heart rate (HR), systolic, diastolic and mean arterial pressures (SAP, DAP and MAP), electrocardiography (ECG), respiratory rate (RR), and body temperature (T) were measured before any drug administration (M0) and 10, 20, 30, 40 and 50 minutes after the start of the continuous infusion of propofol. The numerical data were submitted to Profile of Variance followed by F Test (P 0.05). The HR showed differences among groups at M20 (P2: 91 ± 14,92; P4: 113 ± 17,18; P8: 120 ± 14,84), M30 (P2: 89 ± 13,79; P4: 110 ± 14,3; P8: 114 ± 10,89), and M40 (P2: 88 ± 17,3; P4: 103 ± 16; P8: 109 ± 8,2), wich could be justified because P2 demonstrated minor reduction of MAP. There is no need of HR increasing to establish the cardiac output, and consequently, to maintain the AP. A reduction in SAP about 26,9% to P2, 23,6% to P4 and 30,6% to P8, in PAP about 36,2% to P2; 38,1 to P4 and 52,7% to P8I; and in MAP about 32% to P2, 26,3% to P4 and 38,4% to P8 were observed. These reductions could be related to the decrease of peripheral vascular resistance. It was possible to conclude that the decrease observed in SAP, DAP, MAP and RR are dependent on the infusion rate of propofol, which also caused reduction of the rectal temperature in the 3 groups.
A fim de determinar possíveis alterações nos principais parâmetros fisiológicos determinados pela infusão contínua de propofol, em diferentes doses, foram utilizados 24 cães adultos distribuídos aleatoriamente em 3 grupos (P2, P4 e P8). Os animais foram induzidos à anestesia pela administração intravenosa de propofol (10mg/kg) e, ato contínuo, os cães receberam o anestésico, em infusão contínua nas doses de 0,2mg/kg/min (P2), 0,4mg/kg/min (P4) e 0,8mg/kg/min (P8). As mensurações dos valores das variáveis cardiorrespiratórias [freqüência cardíaca (FC); pressões arteriais sistólica, diastólica e média (PAS, PAD e PAM, respectivamente); eletrocardiografia e freqüência respiratória (f)] e temperatura retal (T) foram realizadas antes da aplicação do fármaco (M0) e após 10, 20, 30, 40 e 50 minutos do início da infusão contínua. Os dados numéricos das variáveis estudadas foram submetidos à Análise de Variância (ANOVA) seguida pelo Teste F (P 0,05). Para FC, observaram-se diferenças entre os grupos no M20 (P2: 91 ± 14,92; P4: 113 ± 17,18; P8: 120 ± 14,84), M30 (P2: 89 ± 13,79; P4: 110 ± 14,3; P8: 114 ± 10,89) e em M40 (P2: 88 ± 17,3; P4: 103 ± 16; P8: 109 ± 8,2), que podem ser justificadas por P2 apresentar menor redução da PAM, não havendo a necessidade de aumento da FC para estabilizar o débito cardíaco e consequentemente para manter a PA. A PAS registrou redução de 26,9% para P2, 23,6% para P4 e 30,6% para P8. Para PAD foram observados decréscimos de 36,2% para P2; 38,1 para P4 e 52,7% para P8, enquanto para PAM a diminuição foi de 32% para P2, 26,3% para P4 e 38,4% para P8. Essas reduções poderiam ser ocasionadas pela diminuição da resistência periférica vascular. Concluiu-se que as reduções ocorridas na PAS, PAD, PAM e f são dependentes da dose de infusão do fármaco, que também proporcionou discreta redução na temperatura retal nos três grupos.
Resumo
The aim of this work was to evaluate the alterations due to butorphanol administration in desflurane anesthetized dogs over heart rate (HR) and electrocardiography (ECG). Twenty adult dogs, males and females, clinically healthy were randomly distributed in two groups of ten animals each (GS and GB). General anesthesia was induced by intravenous administration of propofol (8.4± 0.8mg kg-1) and immediately, the dogs were intubated and submitted to inhalatory anesthesia with desflurane (10V%). After 40 minutes of induction, animals from GS received saline solution at 0.9% (0.05mL kg-1) and from GB received butorphanol (0.4mg kg-1), both applied intramuscularly. Observations of the variables heart rate (HR), duration and amplitude of P wave (Ps e PmV), P-R intervals (PR), QRS complex duration (QRSs), R wave amplitude (RmV), Q-T intervals (QT) and R-R intervals (RR) started immediately before the application of the agents (M0). Serial measurements were carried out in 15 minute intervals after the administration of butorphanol or saline up to 75 minutes, respectively M15, M30, M45, M60 and M75. Numeric data were submitted to Profile Analysis (p 0.05). Heart rate (HR) decreased significantly after butorphanol administration while RR and QT intervals increased. These results allowed to conclude that butorphanol administration in desflurane anesthetized dogs decreases heart rate and promotes a delay in ventricular repolarization.
Objetivou-se com este experimento avaliar as possíveis alterações eletrocardiográficas decorrentes do uso do butorfanol em cães, durante anestesia geral inalatória com desfluorano. Para tal, foram utilizados vinte cães adultos, clinicamente saudáveis, distribuídos em dois grupos (n=10) denominados de GS e GB. Os animais foram induzidos à anestesia com propofol (8,4 ± 0,8mg kg-1, IV) intubados com sonda orotraqueal de Magill e submetidos à anestesia inalatória pelo desfluorano (10V%). Decorridos 40 minutos da indução, foi administrado aos animais do GS, por via intramuscular, 0,05mL kg-1 de solução fisiológica a 0,9% (salina), enquanto que no GB, foi aplicado butorfanol na dose de 0,4mg kg-1 pela mesma via e em volume equivalente ao empregado no grupo anterior. As observações das variáveis freqüência cardíaca (FC), duração e amplitude da onda P (Ps e PmV), intervalo entre as ondas P e R (PR), duração do complexo QRS (QRSs), amplitude da onda R (RmV), duração do intervalo entre as ondas Q e T (QT) e intervalo entre duas ondas R (RR) tiveram início imediatamente antes da aplicação do opióide ou salina (M0). Novas mensurações foram realizadas 15 minutos após a administração do butorfanol ou salina (M15) e as demais colheitas foram realizadas à intervalos de 15 minutos, por um período de 60 minutos (M30, M45, M60 e M75). Os dados numéricos destas variáveis foram submetidos à Análise de Perfil (p 0,05). A freqüência cardíaca apresentou alteração no GB, com média de M0 maior que as demais enquanto que os intervalos RR e QT apresentaram valores de M0 menor que os demais no GB. Os resultados obtidos permitem concluir que a administração do butorfanol em cães submetidos à anestesia pelo desfluorano reduz a freqüência cardíaca e promove retardo na repolarização ventricular.
Resumo
The aim of this study was to evaluate comparatively the effects of buprenorphine administered intramuscularly or intravenously on cardiovascular variables in dogs anesthetized with desflurane. Sixteen adult healthy male and female mongrel dogs were randomly distributed in two groups of eigth animals each (GI and GII). The anesthetic induction was done using propofol (IV), and immediately, the dogs were intubated and submited to desflurane anaesthesia administrated at 1.5 MAC. Thirty minutes after beginning the inhalatory anaesthesia, the GI received buprenorphine (0.02 mg/kg) intravenously whereas the GII group received the opioid at the same dose, by IM injection. Heart Rate (HR); Systolic, Diastolic and Mean Arterial Blood Pressure (SAP, DAP and MAP); Cardiac Output (CO); Central Venous Pressure (CVP) and Pulmonar Arterial Pressure (PAP) were evaluated. The measurements were registered 30 minutes after beginning the inhalatory anaesthesia and before opioid administration (M1); 15 minutes after buprenorphine administration (M2). Serial measurements were carried out in 15-minute intervals after the administration of buprenorphine up to 45 minutes (M3, M4 and M5). The numerical data were submited to Profile Analysis (p 0.05). In both groups, SAP, MAP, CO, CVP and PAP values were not significant. However, only in GI, the HR and DAP decreased significantly after opioid administration. The results allow us to conclude that buprenorphine IV or IM did not produce alterations on the cardiovascular parameters that could provide any significant clinics effects in dogs anesthetized with desflurane.
Objetivou-se avaliar comparativamente os efeitos da buprenorfina, administrada pelas vias intramuscular(IM) ou intravenosa (IV), sobre variáveis cardiovasculares, em cães anestesiados com desfluorano. Para tanto, foram utilizados dezesseis cães adultos, clinicamente saudáveis, distribuídos em dois grupos (n=8) denominados de GI e GII. Em ambos os grupos, a anestesia foi induzida com propofol (8 mg/kg, IV) e em seguida os animais foram intubados com sonda orotraqueal de Magill, a qual foi conectada ao aparelho de anestesia volátil para administração de desfluorano (1,5 CAM). Após 30 minutos do início da anestesia inalatória, foi aplicado no GI buprenorfina na dose de 0,02 mg/kg pela via IV, enquanto no GII administrou-se o opióide na mesma dose porém pela via IM. Avaliaram-se: freqüência cardíaca (FC); pressões arteriais sistólica, diastólica e média (PAS, PAD e PAM); débito cardíaco (DC); pressão venosa central (PVC) e pressão da artéria pulmonar (PAP). As colheitas foram feitas nos seguintes momentos: M1 - 30 minutos após o início da anestesia inalatória antes da aplicação do opióide; M2 - 15 minutos após a administração da buprenorfina; M3, M4 e M5 - de 15 em 15 minutos após M2. A avaliação estatística dos dados foi efetuada por meio de Análise de Perfil (p 0,05). As variáveis PAS, PAM, DC, PVC e PAP, não apresentaram alterações significativas de seus valores em ambos os grupos. Entretanto, a FC e a PAD apresentaram reduções significativas após a administração do opióide apenas no GI. Assim, pôde-se concluir que a buprenorfina administrada pelas vias IV ou IM não interferiu nos índices cardiovasculares de forma a manifestar efeitos clínicos importantes em cães anestesiados com desfluorano.
Resumo
The aim of this study was to evaluate comparatively the effects of buprenorphine administered intramuscularly or intravenously on cardiovascular variables in dogs anesthetized with desflurane. Sixteen adult healthy male and female mongrel dogs were randomly distributed in two groups of eigth animals each (GI and GII). The anesthetic induction was done using propofol (IV), and immediately, the dogs were intubated and submited to desflurane anaesthesia administrated at 1.5 MAC. Thirty minutes after beginning the inhalatory anaesthesia, the GI received buprenorphine (0.02 mg/kg) intravenously whereas the GII group received the opioid at the same dose, by IM injection. Heart Rate (HR); Systolic, Diastolic and Mean Arterial Blood Pressure (SAP, DAP and MAP); Cardiac Output (CO); Central Venous Pressure (CVP) and Pulmonar Arterial Pressure (PAP) were evaluated. The measurements were registered 30 minutes after beginning the inhalatory anaesthesia and before opioid administration (M1); 15 minutes after buprenorphine administration (M2). Serial measurements were carried out in 15-minute intervals after the administration of buprenorphine up to 45 minutes (M3, M4 and M5). The numerical data were submited to Profile Analysis (p 0.05). In both groups, SAP, MAP, CO, CVP and PAP values were not significant. However, only in GI, the HR and DAP decreased significantly after opioid administration. The results allow us to conclude that buprenorphine IV or IM did not produce alterations on the cardiovascular parameters that could provide any significant clinics effects in dogs anesthetized with desflurane.
Objetivou-se avaliar comparativamente os efeitos da buprenorfina, administrada pelas vias intramuscular(IM) ou intravenosa (IV), sobre variáveis cardiovasculares, em cães anestesiados com desfluorano. Para tanto, foram utilizados dezesseis cães adultos, clinicamente saudáveis, distribuídos em dois grupos (n=8) denominados de GI e GII. Em ambos os grupos, a anestesia foi induzida com propofol (8 mg/kg, IV) e em seguida os animais foram intubados com sonda orotraqueal de Magill, a qual foi conectada ao aparelho de anestesia volátil para administração de desfluorano (1,5 CAM). Após 30 minutos do início da anestesia inalatória, foi aplicado no GI buprenorfina na dose de 0,02 mg/kg pela via IV, enquanto no GII administrou-se o opióide na mesma dose porém pela via IM. Avaliaram-se: freqüência cardíaca (FC); pressões arteriais sistólica, diastólica e média (PAS, PAD e PAM); débito cardíaco (DC); pressão venosa central (PVC) e pressão da artéria pulmonar (PAP). As colheitas foram feitas nos seguintes momentos: M1 - 30 minutos após o início da anestesia inalatória antes da aplicação do opióide; M2 - 15 minutos após a administração da buprenorfina; M3, M4 e M5 - de 15 em 15 minutos após M2. A avaliação estatística dos dados foi efetuada por meio de Análise de Perfil (p 0,05). As variáveis PAS, PAM, DC, PVC e PAP, não apresentaram alterações significativas de seus valores em ambos os grupos. Entretanto, a FC e a PAD apresentaram reduções significativas após a administração do opióide apenas no GI. Assim, pôde-se concluir que a buprenorfina administrada pelas vias IV ou IM não interferiu nos índices cardiovasculares de forma a manifestar efeitos clínicos importantes em cães anestesiados com desfluorano.
Resumo
The aim of this work was to evaluate the alterations due to butorphanol administration in desflurane anesthetized dogs over heart rate (HR) and electrocardiography (ECG). Twenty adult dogs, males and females, clinically healthy were randomly distributed in two groups of ten animals each (GS and GB). General anesthesia was induced by intravenous administration of propofol (8.4± 0.8mg kg-1) and immediately, the dogs were intubated and submitted to inhalatory anesthesia with desflurane (10V%). After 40 minutes of induction, animals from GS received saline solution at 0.9% (0.05mL kg-1) and from GB received butorphanol (0.4mg kg-1), both applied intramuscularly. Observations of the variables heart rate (HR), duration and amplitude of P wave (Ps e PmV), P-R intervals (PR), QRS complex duration (QRSs), R wave amplitude (RmV), Q-T intervals (QT) and R-R intervals (RR) started immediately before the application of the agents (M0). Serial measurements were carried out in 15 minute intervals after the administration of butorphanol or saline up to 75 minutes, respectively M15, M30, M45, M60 and M75. Numeric data were submitted to Profile Analysis (p 0.05). Heart rate (HR) decreased significantly after butorphanol administration while RR and QT intervals increased. These results allowed to conclude that butorphanol administration in desflurane anesthetized dogs decreases heart rate and promotes a delay in ventricular repolarization.
Objetivou-se com este experimento avaliar as possíveis alterações eletrocardiográficas decorrentes do uso do butorfanol em cães, durante anestesia geral inalatória com desfluorano. Para tal, foram utilizados vinte cães adultos, clinicamente saudáveis, distribuídos em dois grupos (n=10) denominados de GS e GB. Os animais foram induzidos à anestesia com propofol (8,4 ± 0,8mg kg-1, IV) intubados com sonda orotraqueal de Magill e submetidos à anestesia inalatória pelo desfluorano (10V%). Decorridos 40 minutos da indução, foi administrado aos animais do GS, por via intramuscular, 0,05mL kg-1 de solução fisiológica a 0,9% (salina), enquanto que no GB, foi aplicado butorfanol na dose de 0,4mg kg-1 pela mesma via e em volume equivalente ao empregado no grupo anterior. As observações das variáveis freqüência cardíaca (FC), duração e amplitude da onda P (Ps e PmV), intervalo entre as ondas P e R (PR), duração do complexo QRS (QRSs), amplitude da onda R (RmV), duração do intervalo entre as ondas Q e T (QT) e intervalo entre duas ondas R (RR) tiveram início imediatamente antes da aplicação do opióide ou salina (M0). Novas mensurações foram realizadas 15 minutos após a administração do butorfanol ou salina (M15) e as demais colheitas foram realizadas à intervalos de 15 minutos, por um período de 60 minutos (M30, M45, M60 e M75). Os dados numéricos destas variáveis foram submetidos à Análise de Perfil (p 0,05). A freqüência cardíaca apresentou alteração no GB, com média de M0 maior que as demais enquanto que os intervalos RR e QT apresentaram valores de M0 menor que os demais no GB. Os resultados obtidos permitem concluir que a administração do butorfanol em cães submetidos à anestesia pelo desfluorano reduz a freqüência cardíaca e promove retardo na repolarização ventricular.
Resumo
Nowadays, in the attempt to complement anesthetic patient monitoring, clinical variables analyzes and electrophysiologic techniques are being used. However it is difficult to obtain determinant and uniform information about anesthetic plans for all types of anesthetic agents. Consequently, a monitor of anesthetic depth known as bispectral index (BIS) has been developed through multiple studies and technical advances. Therefor, this review aimed to provide information about the BIS in dogs. Additionally, considerations related to its development, function and proper manipulation were made, and also behavior aspects of this parameter when applied in different anesthetics.
Atualmente, na tentativa de complementar a monitoração anestésica dos pacientes, utilizam-se a análise de variáveis clínicas ou técnicas eletrofisiológicas. Entretanto, é difícil utilizá-las para se obterem informações determinantes e uniformes dos planos anestésicos, para todos os agentes anestésicos. Conseqüentemente, foi desenvolvido, através de múltiplas investigações e avanços tecnológicos, o que se pode definir como monitor de profundidade anestésica, o monitor de índice biespectral (BIS). Desta forma, objetivou-se com este trabalho, fornecer informações a respeito do monitoramento do BIS, em cães. Além disso, foram abordadas considerações relativas ao seu desenvolvimento, função, manipulação adequada e aspectos referentes ao comportamento desta variável quando usada com diferentes agentes anestésicos.
Resumo
The records of 1153 dogs that underwent inhalant general anesthesia at the Veterinary Teaching Hospital of São Paulo State University (UNESP, Campus of Jaboticabal, São Paulo, Brazil) from July 2000 until January 2003 were reviewed. We aimed at determining the mortality and morbidity rates, as well as their correlation with inhalation agents used for anesthetic maintenance, and the American Society of Anesthesiologists (ASA) classification of the patients. The overall morbidity rate was 9.19%, whereas mortality rate was 1.13%. Although the data analysis showed the occurrence of complications and death in patients initially thought to be risk free and in patients where safe anesthetic agents were used, no statistical correlation was determined to exist between morbidity or mortality and either the ASA classification of the animals or the anesthetic agent.
Foram avaliados os prontuários de 1.153 cães submetidos a anestesia geral inalatória no Hospital Veterinário Governador Laudo Natel, da Universidade Estadual Paulista, Campus de Jaboticabal-SP, no período de Julho de 2000 a Janeiro de 2003. Objetivou-se determinar a incidência de mortalidade e morbidade, tentando correlacioná-las com os agentes anestésicos empregados para manutenção anestésica e a classificação do paciente de acordo com a American Society of Anesthesiologists (ASA). A taxa de morbidade e mortalidade foi de, respectivamente, 9,19% e 1,13%. A análise dos dados revelou que as complicações e óbitos podem ocorrer em pacientes cuja previsão de risco é inicialmente pequena, ou ainda naqueles onde os agentes anestésicos considerados mais seguros e estáveis foram utilizados. Entretanto, de acordo com a análise estatística, não houve correlação entre morbidade ou mortalidade e a classificação ASA, do paciente ou o agente anestésico utilizado.
Resumo
The records of 1153 dogs that underwent inhalant general anesthesia at the Veterinary Teaching Hospital of São Paulo State University (UNESP, Campus of Jaboticabal, São Paulo, Brazil) from July 2000 until January 2003 were reviewed. We aimed at determining the mortality and morbidity rates, as well as their correlation with inhalation agents used for anesthetic maintenance, and the American Society of Anesthesiologists (ASA) classification of the patients. The overall morbidity rate was 9.19%, whereas mortality rate was 1.13%. Although the data analysis showed the occurrence of complications and death in patients initially thought to be risk free and in patients where safe anesthetic agents were used, no statistical correlation was determined to exist between morbidity or mortality and either the ASA classification of the animals or the anesthetic agent.
Foram avaliados os prontuários de 1.153 cães submetidos a anestesia geral inalatória no Hospital Veterinário Governador Laudo Natel, da Universidade Estadual Paulista, Campus de Jaboticabal-SP, no período de Julho de 2000 a Janeiro de 2003. Objetivou-se determinar a incidência de mortalidade e morbidade, tentando correlacioná-las com os agentes anestésicos empregados para manutenção anestésica e a classificação do paciente de acordo com a American Society of Anesthesiologists (ASA). A taxa de morbidade e mortalidade foi de, respectivamente, 9,19% e 1,13%. A análise dos dados revelou que as complicações e óbitos podem ocorrer em pacientes cuja previsão de risco é inicialmente pequena, ou ainda naqueles onde os agentes anestésicos considerados mais seguros e estáveis foram utilizados. Entretanto, de acordo com a análise estatística, não houve correlação entre morbidade ou mortalidade e a classificação ASA, do paciente ou o agente anestésico utilizado.