Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Arq. bras. med. vet. zootec ; 68(1): 252-256, jan.-fev. 2016. ilus, tab
Artigo em Português | LILACS, VETINDEX | ID: biblio-874992

Resumo

Acupuncture derives from traditional Chinese medicine, which aims to restore homeostasis. The action mechanism of this technique involves stimulation of certain points on the skin by inserting a needle. The aim of this study was to evaluate the influence of stimulation of acupoints C7 and PC6 on the heart rate variability, heart rate and heart rhythm in healthy dogs. 30 male and female adult dogs were used, with no breed restriction. The animals were analyzed at two different times in weekly intervals. Firstly were applied needles in the true acupoints, and on the second time we applied needles in false acupoints. Previously to the acupuncture an ECG with 2 minutes of recorder was performed, and after an insertion of needles the electrocardiographic recording was maintained during the 30 minutes of acupuncture. Results showed no significant difference between the HR when comparing true and false acupoints (p = 0.890). For heart rate variability a small difference was observed between the groups (p = 0.0051), however, when comparing the baseline with 15 and 25 minutes of monitoring in the false acupoint group, no significant results were found when compared with true acupoint. In conclusion, it is suggested that the stimulation of acupoints C-7 and PC-6 in healthy dogs does not promote change in sympathovagal balance, specifically on the heart rate variability, heart rate and heart rhythm on healthy dogs.(AU)


Assuntos
Animais , Cães , Pontos de Acupuntura , Terapia por Acupuntura/veterinária , Frequência Cardíaca , Sistema Nervoso Parassimpático , Sistema Nervoso Simpático
2.
Artigo em Português | VETINDEX | ID: vti-447915

Resumo

Acupuncture derives from traditional Chinese medicine, which aims to restore homeostasis. The action mechanism of this technique involves stimulation of certain points on the skin by inserting a needle. The aim of this study was to evaluate the influence of stimulation of acupoints C7 and PC6 on the heart rate variability, heart rate and heart rhythm in healthy dogs. 30 male and female adult dogs were used, with no breed restriction. The animals were analyzed at two different times in weekly intervals. Firstly were applied needles in the true acupoints, and on the second time we applied needles in false acupoints. Previously to the acupuncture an ECG with 2 minutes of recorder was performed, and after an insertion of needles the electrocardiographic recording was maintained during the 30 minutes of acupuncture. Results showed no significant difference between the HR when comparing true and false acupoints (p = 0.890). For heart rate variability a small difference was observed between the groups (p = 0.0051), however, when comparing the baseline with 15 and 25 minutes of monitoring in the false acupoint group, no significant results were found when compared with true acupoint. In conclusion, it is suggested that the stimulation of acupoints C-7 and PC-6 in healthy dogs does not promote change in sympathovagal balance, specifically on the heart rate variability, heart rate and heart rhythm on healthy dogs.

3.
Ars vet ; 31(1): 57-62, 2015. tab, graf
Artigo em Português | VETINDEX | ID: biblio-1463244

Resumo

The present study aimed to determine the accuracy of measurement of blood pressure (BP) by digital palpation of peripheral pulse (indirect method) in anesthetized dogs. Indirect determination of BP was performed using a sphygmomanometer and a cuff placed proximal to carpus and BP was defined as the value recorded by sphygmomanometer at the time that digital palpation of the pulse in metacarpal artery returned after occlusion and subsequent gradual cuff deflation. Blood pressure was measured simultaneously by invasive (direct) method. Data were compared by Bland Altman analysis to verify the agreement between methods. A total of 131, 65 and 56 observations were performed in 31 dogs during normotension, hypotension and hypertension, respectively. During hypotension, normotension and hypertension, values of bias for systolic arterial pressure (SAP) between methods were respectively - 2, 8 and 12 mmHg, demonstrating underestimation of SAP by the indirect method during normotension and hypertension. Percentages of differences between methods for SAP that were 10 e 20 mmHg were: hypotension, 49 and 88%; normotension, 47 and 79%; hypertension, 25 and 52%. For determination of SAP in dogs, indirect method reported here have lower agreement with the invasive method compared with Doppler and similar to many oscillometric monitors reported in the literature, but do not meet the requirements established by the ACVIM. Use of digital palpation of peripheral pulse for monitoring blood pressure during anesthesia in dogs requires further studies to more accurately determine the accuracy of this method


Com o presente estudo, buscou-se determinar a acurácia da aferição da pressão arterial (PA) pela palpação digital do pulso periférico (método indireto) em cães anestesiados. A determinação indireta da PA foi realizada com auxílio de manguito e esfigmomanômetro posicionados proximais ao carpo e o valor da PA foi considerado aquele registrado pelo esfigmomanômetro no momento em que a palpação do pulso retornava na artéria metacarpiana após a oclusão e subsequente desinsuflação gradual do manguito. A PA foi mensurada simultaneamente pelo método invasivo (direto). Os dados foram comparados pela análise de Bland Altman para verificar a concordância entre os métodos. Foram realizadas 131, 65 e 56 observações em 31 cães, respectivamente em normotensão, hipotensão e hipertensão. Durante a normotensão, hipotensão e hipertensão, os valores do viés para a pressão arterial sistólica (PAS) entre os métodos foram respectivamente 8, -2 e 12 mmHg, demonstrando subestimação desta variável pelo método indireto na normotensão e hipertensão. Para a PAS, as diferenças entre os métodos que constituíram 10 e 20 mmHg foram respectivamente: hipotensão, 49 e 88%; normotensão, 47 e 79%; hipertensão, 25 e 52%. Quando utilizado para a determinação da PAS em cães, o método de palpação digital do pulso periférico apresenta concordância inferior com o método invasivo em relação ao Doppler e similar em relação à PAS mensurada por diversos monitores oscilométricos relatados na literatura, mas não cumpre as exigências estabelecidas pelo CAMIV. O uso do método de palpação do pulso periférico para a monitoração da pressão arterial em cães durante a anestesia requer outros estudos para determinar com maior precisão a acurácia desse método


Assuntos
Animais , Cães , Palpação/veterinária , Pressão Arterial , Pulso Arterial/veterinária , Determinação da Pressão Arterial/veterinária , Ecocardiografia Doppler/veterinária , Frequência Cardíaca , Oscilometria/veterinária , Pressão Sanguínea
4.
Ars Vet. ; 31(1): 57-62, 2015. tab, graf
Artigo em Português | VETINDEX | ID: vti-304355

Resumo

The present study aimed to determine the accuracy of measurement of blood pressure (BP) by digital palpation of peripheral pulse (indirect method) in anesthetized dogs. Indirect determination of BP was performed using a sphygmomanometer and a cuff placed proximal to carpus and BP was defined as the value recorded by sphygmomanometer at the time that digital palpation of the pulse in metacarpal artery returned after occlusion and subsequent gradual cuff deflation. Blood pressure was measured simultaneously by invasive (direct) method. Data were compared by Bland Altman analysis to verify the agreement between methods. A total of 131, 65 and 56 observations were performed in 31 dogs during normotension, hypotension and hypertension, respectively. During hypotension, normotension and hypertension, values of bias for systolic arterial pressure (SAP) between methods were respectively - 2, 8 and 12 mmHg, demonstrating underestimation of SAP by the indirect method during normotension and hypertension. Percentages of differences between methods for SAP that were 10 e 20 mmHg were: hypotension, 49 and 88%; normotension, 47 and 79%; hypertension, 25 and 52%. For determination of SAP in dogs, indirect method reported here have lower agreement with the invasive method compared with Doppler and similar to many oscillometric monitors reported in the literature, but do not meet the requirements established by the ACVIM. Use of digital palpation of peripheral pulse for monitoring blood pressure during anesthesia in dogs requires further studies to more accurately determine the accuracy of this method(AU) 


Com o presente estudo, buscou-se determinar a acurácia da aferição da pressão arterial (PA) pela palpação digital do pulso periférico (método indireto) em cães anestesiados. A determinação indireta da PA foi realizada com auxílio de manguito e esfigmomanômetro posicionados proximais ao carpo e o valor da PA foi considerado aquele registrado pelo esfigmomanômetro no momento em que a palpação do pulso retornava na artéria metacarpiana após a oclusão e subsequente desinsuflação gradual do manguito. A PA foi mensurada simultaneamente pelo método invasivo (direto). Os dados foram comparados pela análise de Bland Altman para verificar a concordância entre os métodos. Foram realizadas 131, 65 e 56 observações em 31 cães, respectivamente em normotensão, hipotensão e hipertensão. Durante a normotensão, hipotensão e hipertensão, os valores do viés para a pressão arterial sistólica (PAS) entre os métodos foram respectivamente 8, -2 e 12 mmHg, demonstrando subestimação desta variável pelo método indireto na normotensão e hipertensão. Para a PAS, as diferenças entre os métodos que constituíram 10 e 20 mmHg foram respectivamente: hipotensão, 49 e 88%; normotensão, 47 e 79%; hipertensão, 25 e 52%. Quando utilizado para a determinação da PAS em cães, o método de palpação digital do pulso periférico apresenta concordância inferior com o método invasivo em relação ao Doppler e similar em relação à PAS mensurada por diversos monitores oscilométricos relatados na literatura, mas não cumpre as exigências estabelecidas pelo CAMIV. O uso do método de palpação do pulso periférico para a monitoração da pressão arterial em cães durante a anestesia requer outros estudos para determinar com maior precisão a acurácia desse método(AU)


Assuntos
Animais , Cães , Pressão Arterial , Palpação/veterinária , /veterinária , Pulso Arterial/veterinária , Frequência Cardíaca , Pressão Sanguínea , Determinação da Pressão Arterial/veterinária , Ecocardiografia Doppler/veterinária , Oscilometria/veterinária
5.
Arq. bras. med. vet. zootec. (Online) ; 67(4): 1025-1032, jul.-ago. 2015. tab, ilus
Artigo em Português | VETINDEX | ID: vti-324241

Resumo

A eletrocardiografia computadorizada é mais precisa e prática quando comparada à convencional e por essa razão vem ganhando espaço na rotina clínica. No entanto os valores de referência devem diferir para os dois métodos. O objetivo desse trabalho foi analisar e comparar o exame eletrocardiográfico computadorizado com o exame obtido pelo método convencional em equinos. O estudo demonstrou diferenças na amplitude da onda P (P<0,0001) com valor médio de 0,21 mV para o método convencional e 0,17 mV para o computadorizado; duração do intervalo PR (p=0,0005), tendo o valor médio de 260,49 ms para o método convencional e 242,37 ms para o informatizado e duração do complexo QRS (p=0,0003), sendo a média de valores para o método convencional de 75,61ms e 84,83 ms para o computadorizado. Essas diferenças devem ser levadas em consideração com o intuito de evitar equívocos na interpretação da eletrocardiografia na espécie equina.(AU)


Computerized electrocardiography has been gaining space in clinic routines because it is more practical and precise when compared to the conventional method. However, their reference values may differ from each other. The aim of this paper was to analyze and compare computerized and conventional electrocardiography in horses. Differences were observed between P wave amplitude (P<0001) with a mean of 0.21mV in the conventional method and 0.17mV in the computerized method, PR interval duration (p=0.0005) with a mean of 260.49 ms and 242.37 ms in the conventional and computerized methods respectively, and QRS complex duration (p=0.0003) with a mean of 75.61 ms in the conventional method and 84.83 ms in the computerized method. These differences should be taken into consideration in order to avoid misunderstandings in the interpretation of the electrocardiogram in equine species.(AU)


Assuntos
Animais , Cavalos , Eletrocardiografia , Informática Médica/tendências , Informática Médica/métodos , Exames Médicos/análise
6.
Arq. bras. med. vet. zootec ; 66(1): 310-314, fev. 2014. ilus
Artigo em Português | VETINDEX | ID: vti-10283

Resumo

This paper describes the occurrence of cor triatriatum sinister, a rare cardiac malformation in dogs, associated with pulmonary edema and pulmonary hypertension in a 5-year-old Poodle female with history of acute dyspnea and cyanosis. The animal presented acute respiratory failure, heart failure with low cardiac output, progressing to acute tubular necrosis and death. The diagnosis was made posmortem due to the clinical instability of the dog. This malformation was diagnosed by the subdivision of the left atrium into two compartments separated by an abnormal fibromuscular membrane, absence of structural abnormalities of the mitral valve and thickening of pulmonary artery tunica media associated with renal tubular degeneration. The occurrence of cor triatriatum in dogs is most common in the right atrium, defined as cor triatriatum dexter. Additionally, pulmonary arterial hypertension associated with this malformation is described only in humans with this heart defect.(AU)


Assuntos
Animais , Cães , Hipertensão/patologia , Artéria Pulmonar/anatomia & histologia , Cardiopatias Congênitas/diagnóstico , Cães/classificação
7.
Ars vet ; 29(3): 132-138, 2013.
Artigo em Português | VETINDEX | ID: biblio-1463059

Resumo

A pressão arterial (PA) é definida pela força exercida pelo sangue por unidade de superfície da parede vascular, refletindo a interação do débito cardíaco com a resistência periférica sistêmica. A pressão sistólica representa a mais alta pressão nas artérias, sendo associada com a sístole ventricular cardíaca. A aferição indireta da pressão arterial ainda é subutilizada na medicina equina, mas oscilações já foram descritas em casos de cólica, laminite e epistaxe. São diversas as formas de aferição usadas, destacando-se as técnicas invasivas e não invasivas (oscilométrica e guiada pelo uso do Doppler). O presente trabalho teve como objetivo avaliar a influência do exercício físico (marcha) sobre os valores registrados para pressão arterial sistólica em equinos. Foram avaliados 10 equinos da raça Mangalarga Marchador, com idade de 6,7 ± 2,95 anos e peso médio de 426,60 ± 32,44 Kg, sendo quatro machos e seis fêmeas. Procedeu-se avaliação indireta da PA por método oscilométrico em dois diferentes momentos: repouso (T0) e com 5 minutos (T1) após o término do exercício, representado por 40 minutos de marcha. Os resultados foram analisados através da comparação entre médias (teste-t), considerando o nível de significância de 5%. Foram registrados valores CUCV (valores coccígeos não corrigidos) de 147±7 mmHg e 169±9 mmHg, respectivamente nos momentos T0 e T1. A análise dos resultados demonstrou que a marcha influenciou de forma significativa os valores registrados para pressão arterial sistólica (p<0,0001) e esse aumento pode ser justificado pela elevação do débito cardíaco em função da intensidade do exercício. Tal variável poderia ser um índice cardíaco utilizado para avaliar a condição física cavalos.


Arterial blood pressure can be defined by the blood pressure per surface unit of vascular wall, reflecting the interaction between cardiac output and peripherical vascular resistance. Systolic arterial pressure is the highest value on arteries, being associated with cardiac ventricular systole. Indirect blood pressure measurement is infrequently carried out in horses, but variations from normal have been reported in colic, laminitis and epistaxis. A number of methods for indirectly measuring arterial blood pressure have been reported including invasive and non-invasive (oscillometric and ultrasonic-Doppler) techniques. The aim of this study was evaluate the influence of physical exercise (marcha gait) on values of systolic arterial pressure in horses. The study included ten adult Mangalarga Marchador horses (four males and six females) with mean weight of 426.60 ± 32.44 Kg and mean age of 6.7 ± 2.95 years old. Indirect measurements were obtained by oscillometric method in two different moments: rest (T0) and 5 minutes (T1) after the exercise. Comparisons between the moments were made using t-test and a value of p<0.05 was considered significant for all comparisons. Coccygeal, uncorrected values (CUCV) were 147±7 mmHg and 169±9 mmHg, respectively, at T0 and T1. The results showed that marcha gait leaded to significantly increase on systolic arterial pressure (p<0.0001) and this occurred because of an increase of cardiac output due exercise. This clinical parameter could be used as a cardiac index for the evaluation of athletic horses.


Assuntos
Animais , Cavalos/anormalidades , Cavalos/sangue
8.
Ars Vet. ; 29(3): 132-138, 20130000.
Artigo em Português | VETINDEX | ID: vti-11757

Resumo

A pressão arterial (PA) é definida pela força exercida pelo sangue por unidade de superfície da parede vascular, refletindo a interação do débito cardíaco com a resistência periférica sistêmica. A pressão sistólica representa a mais alta pressão nas artérias, sendo associada com a sístole ventricular cardíaca. A aferição indireta da pressão arterial ainda é subutilizada na medicina equina, mas oscilações já foram descritas em casos de cólica, laminite e epistaxe. São diversas as formas de aferição usadas, destacando-se as técnicas invasivas e não invasivas (oscilométrica e guiada pelo uso do Doppler). O presente trabalho teve como objetivo avaliar a influência do exercício físico (marcha) sobre os valores registrados para pressão arterial sistólica em equinos. Foram avaliados 10 equinos da raça Mangalarga Marchador, com idade de 6,7 ± 2,95 anos e peso médio de 426,60 ± 32,44 Kg, sendo quatro machos e seis fêmeas. Procedeu-se avaliação indireta da PA por método oscilométrico em dois diferentes momentos: repouso (T0) e com 5 minutos (T1) após o término do exercício, representado por 40 minutos de marcha. Os resultados foram analisados através da comparação entre médias (teste-t), considerando o nível de significância de 5%. Foram registrados valores CUCV (valores coccígeos não corrigidos) de 147±7 mmHg e 169±9 mmHg, respectivamente nos momentos T0 e T1. A análise dos resultados demonstrou que a marcha influenciou de forma significativa os valores registrados para pressão arterial sistólica (p<0,0001) e esse aumento pode ser justificado pela elevação do débito cardíaco em função da intensidade do exercício. Tal variável poderia ser um índice cardíaco utilizado para avaliar a condição física cavalos.(AU)


Arterial blood pressure can be defined by the blood pressure per surface unit of vascular wall, reflecting the interaction between cardiac output and peripherical vascular resistance. Systolic arterial pressure is the highest value on arteries, being associated with cardiac ventricular systole. Indirect blood pressure measurement is infrequently carried out in horses, but variations from normal have been reported in colic, laminitis and epistaxis. A number of methods for indirectly measuring arterial blood pressure have been reported including invasive and non-invasive (oscillometric and ultrasonic-Doppler) techniques. The aim of this study was evaluate the influence of physical exercise (marcha gait) on values of systolic arterial pressure in horses. The study included ten adult Mangalarga Marchador horses (four males and six females) with mean weight of 426.60 ± 32.44 Kg and mean age of 6.7 ± 2.95 years old. Indirect measurements were obtained by oscillometric method in two different moments: rest (T0) and 5 minutes (T1) after the exercise. Comparisons between the moments were made using t-test and a value of p<0.05 was considered significant for all comparisons. Coccygeal, uncorrected values (CUCV) were 147±7 mmHg and 169±9 mmHg, respectively, at T0 and T1. The results showed that marcha gait leaded to significantly increase on systolic arterial pressure (p<0.0001) and this occurred because of an increase of cardiac output due exercise. This clinical parameter could be used as a cardiac index for the evaluation of athletic horses.(AU)


Assuntos
Animais , Cavalos/anormalidades , Cavalos/sangue
9.
Ars vet ; 27(2): 085-093, 2011. tab
Artigo em Inglês, Português | VETINDEX | ID: biblio-1462909

Resumo

Severe degenerative myxomatous mitral valve disease (DMMVD) is a common condition in dogs. Therefore, a clinical study was conducted to determine the effectiveness of different treatment protocols based on enalapril maleate, furosemide, spironolactone, and their associations, to treat dogs with DMMVD belonging to functional class II congestive heart failure (CHF). For this purpose, 20 dogs were divided into two groups (n = 10), where the first received enalapril maleate (0.5 mg/kg) and furosemide (2 mg/kg) and the second enalapril maleate spironolactone (1 mg/kg) and furosemide, administered once a day for 56 days. The dogs were evaluated four different times regarding clinical signs, radiographic, electrocardiographic, echocardiographic and blood pressure. However, hematological and biochemical-serum, which included mainly serum concentrations of angiotensin converting enzyme (ACE) and aldosterone, were implemented at the beginning and end of the experiment. The results were characterized by animals with mitral murmur grade III to V/VI with reduced clinical signs after administration of therapeutic protocols. Laboratory tests revealed significant reduction (p<0.01) for values of ACE and aldosterone in both groups. The radiographic examination showed significant reductions (p<0.05) in VHS and variable wave Pms ECG in both groups. Moreover, the Doppler echocardiography showed significant decrease (p<0.05) variables LVD d/s IVS d/s, mean LA/AO, FS% and the speed of mitral valve regurgitation. Therefore, the analysis of the results showed the effectiveness of treatment protocols used, especially when combined with spironolactone.


Devido à prevalência de cães portadores da doença degenerativa mixomatosa da válvula mitral (DMMVD) realizou-se uma investigação clínica da eficácia de diferentes protocolos terapêuticos a base de maleato de enalapril, furosemida. espironolactona e suas associações, em cães com DMMVD pertencentes à classe funcional II da insuficiência cardíaca congestiva (ICC). Para tanto, utilizaram-se 20 cães distribuídos em dois grupos (n=10), com o primeiro recebendo maleato de enalapril (0.5 mg/kg) e furosemida (2 mg/kg) e o segundo, maleato de enalapril associado à espironolactona (1 mg/kg) e furosemida, administrados uma vez ao dia durante 56 dias. Os cães foram avaliados em quatro momentos quanto aos sinais clínicos, avaliações radiográficas, eletrocardiográficas, ecodopplercardiográficas e aferição da pressão arterial. Entretanto, em relação aos parâmetros hematológicos e bioquímico-séricos, que incluíram mormente as concentrações séricas da enzima conversora da angiotensina (ECA) e aldosterona, estas foram executadas no início e ao final do experimento. Os resultados obtidos caracterizaram-se animais portadores de sopro foco mitral grau III a V/VI com redução dos sinais clínicos após administração das terapias. Os exames laboratoriais revelaram redução significativa (p<0,01) dos valores de ECA e aldosterona em ambos os grupos. Ao exame radiográfico observou-se reduções significativas (p<0,05) nos valores VHS e na variável onda Pms do eletrocardiograma nos grupos. Outrossim, o ecodopplercardiograma evidenciou diminuição significativa (p<0,05) dos DIVEd/s, ESIVd/s, relação AE/Ao, FEC% e na velocidade da regurgitação válvula mitral. Portanto, os resultados evidenciaram efetividade dos protocolos terapêuticos utilizados, principalmente com associação à espironolactona.


Assuntos
Animais , Cães , Espironolactona/administração & dosagem , Enalapril/administração & dosagem , Furosemida/administração & dosagem , Doenças das Valvas Cardíacas/veterinária , Valva Mitral/patologia
10.
Arq. bras. med. vet. zootec ; 63(2): 317-321, abr. 2011. ilus, tab
Artigo em Português | VETINDEX | ID: vti-5937

Resumo

Estudaram-se os parâmetros eletrocardiográficos utilizando-se os métodos convencional, computadorizado e computadorizado impresso de 30 cães da raça Beagle clinicamente normais. As medidas eletrocardiográficas dos três diferentes traçados foram analisadas na derivação DII. A comparação entre os métodos revelou diferença nos valores da onda P, onda R, complexo QRS, intervalo QT e intervalo PR e na polaridade da onda T. Este fato deve ser levado em consideração, na dependência do método a ser utilizado.(AU)


Electrocardiographic parameters were studied in thirty healthy adult Beagles, using conventional and computerized methods and reading the computerized registration printed on paper. The electrocardiographic measurements of the three different tracings were analyzed in lead II. The results obtained showed that there are differences among the three methods for P wave, R wave, QRS complex, QT interval, PR interval and polarity of the T wave. Special attention should be given to these differences, depending on the chosen method.(AU)


Assuntos
Animais , Eletrocardiografia , Cães/classificação , Arritmias Cardíacas/veterinária
11.
Ars vet ; 26(3): 132-137, 2010. tab
Artigo em Inglês | VETINDEX | ID: biblio-1419078

Resumo

The cardiovascular response to acute normovolemic anemia is related to activation of compensatory mechanisms that can cause changes in the electrocardiogram. The electrocardiographic examination demonstrates the occurrence of arrhythmias and may suggest the presence of atrial and ventricular enlargement or myocardium hypoxia. The aim of this study is to describe cardiac rhythm, heart rate and ECG pattern in dogs undergoing acute normovolemic anemia. The dogs were submitted to computerized electrocardiography 15 minutes and 24 hours after induction of anemia and evaluated by Holter, with 24 hours of continuous electrocardiographic monitoring. Anemic dogs had no arrhythmias or premature ventricular and atrial complexes related to hypoxia and it were observed reductions in the incidence of sinus arrhythmia. Although there was no development of sinus tachycardia, there was a significant increase (P = 0.01) in heart rate (bpm) in both assessments made after installation of anemia (100.90 ± 23.1 to 132.50 ± 12.7 and 132.70 ± 23.9). The increased heart rate was linearly related to the fall in hematocrit (R2 = 0.27, P = 0.018). In addition, this study identified changes in the amplitude and duration of P wave and PR interval, without clinical significance because they were within the normal range for the specie. Therefore, dogs with acute normovolemic anemia and volemic reposition with Ringer's lactate solution and hydroxyethyl starch-based, with hematocrit of 14.37 ± 2.99%, did not develop significantly arrhythmias, extrasystoles or electrocardiographic patterns consistent with myocardial hypoxia and the electrocardiographic changes found may be related compensatory mechanisms activated.


A resposta cardiovascular à anemia normovolêmica aguda está relacionada à ativação de mecanismos compensatórios que podem acarretar alterações ao eletrocardiograma. O exame eletrocardiográfico demonstra a ocorrência de arritmias, bem como pode sugerir a presença de sobrecarga atrial e ventricular ou hipóxia do miocárdio. O objetivo deste estudo é descrever o ritmo cardíaco, freqüência cardíaca e padrão eletrocardiográfico em cães submetidos à anemia normovolêmica aguda. Foram realizados registros eletrocardiográficos computadorizados e eletrocardiografia dinâmica com holter de 24 horas. Os cães anêmicos não apresentaram arritmias ou extrassístoles atriais e ventriculares relacionadas à hipóxia e observou-se diminuição da incidência de arritmia sinusal. Apesar de não haver desenvolvimento de taquicardia sinusal, houve aumento significativo (P=0.01) da frequência cardíaca (bpm) nas duas avaliações realizadas após a instalação da anemia (100,90 23,1 para 132,50 ± 12,7 e 132,70 ± 23,9), relacionando-se ao hematócrito (R² = 0,27; P = 0,018). Foram identificadas alterações na amplitude e duração de onda P e intervalo PR porém sem significado clínico pois estavam dentro dos valores de normalidade para a espécie. Portanto, cães com anemia normovolêmica aguda e reposição volêmica com solução Ringer com lactato e amido hidroxietílico, com hematocrito de 14,37 ± 2,99%, não desenvolveram arritmias ou alterações eletrocardiográficas compatíveis com hipóxia do miocárdio significativas, apresentaram aumento da frequência cardíaca linearmente relacionado à queda do hematocrito e as alterações encontradas podem ter relação com os mecanismos compensatórios ativados.


Assuntos
Animais , Cães , Arritmias Cardíacas/veterinária , Hemoglobinas/análise , Eletrocardiografia/veterinária , Coração/fisiologia , Hemodiluição/veterinária
12.
Ars vet ; 25(3): 125-128, 2009. ilus
Artigo em Inglês | VETINDEX | ID: biblio-1452579

Resumo

The exocrine pancreatic insufficiency (EPI) is a digestive disease caused by atrophy or inflammation of pancreatic acinar cells, resulting in nutrient malabsorption and clinical signs related to malnutrition. Three German Shepherds were presented at the Veterinary Hospital with background and clinical signs compatible with EPI, what was confirmed by routine laboratory testing. On physical examination, both presented bradyarrhythmias confirmed by computerized electrocardiogram. After therapy for EPI, the bradyarrhythmias were solved. The authors discuss the influence of the gastrointestinal hormone cholecystokinin, which can increase in pancreatic exocrine impairment, possibly reflecting a failure to provide feedback down-modulation of CCK release, causing cardiovascular effects, such as chronotropic and inotropic negative actions and promoting bradycardia.


A insuficiência pancreática exócrina (IPE) é uma enfermidade causada por atrofia ou inflamação das células acinares pancreáticas, resultando em má absorção de nutrientes e sinais clínicos relacionados à desnutrição. Três pastores alemães foram atendidos no Hospital Veterinário com histórico e sinais clínicos compatíveis com IPE, diagnosticada através de testes laboratoriais de rotina. Ao exame físico, os três animais apresentaram bradiarritmias, que foram confirmadas por eletrocardiograma computadorizado. Após o tratamento da IPE, houve normalização dos valores de freqüência cardíaca de todos os pacientes. Os autores discutem a influência do hormônio colecistoquinina, que pode estar elevado em casos de insuficiência pancreática exócrina e que, por sua vez, exerce efeitos cardiovasculares tais como cronotropismo e inotropismo negativos, promovendo desta forma a bradicardia destes pacientes.


Assuntos
Animais , Cães , Insuficiência Pancreática Exócrina/veterinária , Bradicardia/veterinária , Colecistocinina/análise , Frequência Cardíaca , Eletrocardiografia/veterinária , Contração Miocárdica
13.
Arq. bras. med. vet. zootec ; 60(5): 1045-1052, out. 2008. ilus
Artigo em Inglês | VETINDEX | ID: vti-6610

Resumo

The effects of topical levobunolol with the fixed combination of 2 percent dorzolamide-0.5 percent timolol and the association of 2 percent dorzolamide with 0.5 percent levobunolol on intraocular pressure (IOP), pupil size (PS), heart rate (HR), and conjunctival hyperemia in eighteen halthy cats were investigated and compared. IOP, PS, HR, and conjuntival hyperemia were daily recorded at three times (9a.m., 2p.m., and 6p.m.). Three groups were formed (n=6), and one eye of each animal was randomly selected and treated with topical levobunolol (L), or commercial combination of dorzolamide-timolol (DT), or the association of dorzolamide with levobunolol (DL). The first day (0) consisted of recording of baseline values. On the next four consecutive days, drugs were instilled at 8a.m. and 8p.m. and measurements were taken at the same times fore cited. Comparing with the baseline values, all evaluated parameters significantly decreased (P<0.001). Conjuntival hyperemia was not seen. Levobunolol significantly declined IOP, PS, and HR in normal cats, and showed a stronger effect in lowering HR, when compared to dorzolamide-timolol effect. No synergistic effect in IOP declining was noted when levobunolol dorzolamide was added to levobunolol.(AU)


Estudaram-se e compararam-se os efeitos do levobunolol, da combinação fixa de dorzolamida 2 por cento-timolol 0,5 por cento e da associação de dorzolamida 2 por cento com levobunolol 0,5 por cento sobre a pressão intra-ocular (PIO), o diâmetro pupilar (DP), a freqüência cardíaca (FC) e a hiperemia conjuntival em 18 gatos saudáveis. PIO, DP, FC e hiperemia conjuntival foram aferidos diariamente, em três horários distintos (9h, 14h e 18h). Três grupos foram formados (n=6) e um olho de cada animal recebeu, aleatoriamente, uma gota de levobunolol (L), ou a combinação comercial à base de dorzolamida-timolol (DT), ou a associação de dorzolamida com levobunolol (DL). Parâmetros basais foram aferidos no primeiro dia (dia 0). Nos quatro dias consecutivos, os fármacos foram instilados às 8h e 20h e os parâmetros aferidos nos mesmos horários. Todos os parâmetros decresceram significativamente em relação aos valores basais (P<0,001) e não se observou hiperemia conjuntival. O levobunolol reduziu significativamente a PIO, o DP e a FC e o foi o fármaco que mais reduziu a FC. Não se observou efeito sinérgico na redução da PIO quando a dorzolamida foi adicionada ao levobulol.(AU)


Assuntos
Animais , Levobunolol/efeitos adversos , Pressão Intraocular , Pupila/fisiologia , Frequência Cardíaca , Gatos
14.
Ars vet ; 31(1): 57-62, 2015.
Artigo em Português | VETINDEX | ID: vti-765016

Resumo

Com o presente estudo, buscou-se determinar a acurácia da aferição da pressão arterial (PA) pela palpação digital do pulso periférico (método indireto) em cães anestesiados. A determinação indireta da PA foi realizada com auxílio de manguito e esfigmomanômetro posicionados proximais ao carpo e o valor da PA foi considerado aquele registrado pelo esfigmomanômetro no momento em que a palpação do pulso retornava na artéria metacarpiana após a oclusão e subsequente desinsuflação gradual do manguito. A PA foi mensurada simultaneamente pelo método invasivo (direto). Os dados foram comparados pela análise de Bland Altman para verificar a concordância entre os métodos. Foram realizadas 131, 65 e 56 observações em 31 cães, respectivamente em normotensão, hipotensão e hipertensão. Durante a normotensão, hipotensão e hipertensão, os valores do viés para a pressão arterial sistólica (PAS) entre os métodos foram respectivamente 8, -2 e 12 mmHg, demonstrando subestimação desta variável pelo método indireto na normotensão e hipertensão. Para a PAS, as diferenças entre os métodos que constituíram

15.
Braz. j. vet. res. anim. sci ; 40: 228-229, 2003.
Artigo em Português | VETINDEX | ID: vti-711105

Resumo

O artigo não apresenta resumo.

16.
Braz. j. vet. res. anim. sci ; 40: 172-173, 2003.
Artigo em Português | VETINDEX | ID: vti-710932

Resumo

O artigo não apresenta resumo.

17.
Ars Vet. ; 26(3): 132-137, 2010.
Artigo em Português | VETINDEX | ID: vti-714760

Resumo

The cardiovascular response to acute normovolemic anemia is related to activation of compensatory mechanisms that can cause changes in the electrocardiogram. The electrocardiographic examination demonstrates the occurrence of arrhythmias and may suggest the presence of atrial and ventricular enlargement or myocardium hypoxia. The aim of this study is to describe cardiac rhythm, heart rate and ECG pattern in dogs undergoing acute normovolemic anemia. The dogs were submitted to computerized electrocardiography 15 minutes and 24 hours after induction of anemia and evaluated by Holter, with 24 hours of continuous electrocardiographic monitoring. Anemic dogs had no arrhythmias or premature ventricular and atrial complexes related to hypoxia and it were observed reductions in the incidence of sinus arrhythmia. Although there was no development of sinus tachycardia, there was a significant increase (P = 0.01) in heart rate (bpm) in both assessments made after installation of anemia (100.90 ± 23.1 to 132.50 ± 12.7 and 132.70 ± 23.9). The increased heart rate was linearly related to the fall in hematocrit (R2 = 0.27, P = 0.018). In addition, this study identified changes in the amplitude and duration of P wave and PR interval, without clinical significance because they were within the normal range for the specie. Therefore, dogs with acute normovolemic anemia and volemic reposition with

18.
Ars Vet. ; 27(2): 085-093, 2011.
Artigo em Português | VETINDEX | ID: vti-714738

Resumo

Devido à prevalência de cães portadores da doença degenerativa mixomatosa da válvula mitral (DMMVD) realizou-se uma investigação clínica da eficácia de diferentes protocolos terapêuticos a base de maleato de enalapril, furosemida, espironolactona e suas associações, em cães com DMMVD pertencentes à classe funcional II da insuficiência cardíaca congestiva (ICC). Para tanto, utilizaram-se 20 cães distribuídos em dois grupos (n=10), com o primeiro recebendo maleato de enalapril (0,5 mg/kg) e furosemida (2 mg/kg) e o segundo, maleato de enalapril associado à espironolactona (1 mg/kg) e furosemida, administrados uma vez ao dia durante 56 dias. Os cães foram avaliados em quatro momentos quanto aos sinais clínicos, avaliações radiográficas, eletrocardiográficas, ecodopplercardiográficas e aferição da pressão arterial. Entretanto, em relação aos parâmetros hematológicos e bioquímico-séricos, que incluíram mormente as concentrações séricas da enzima conversora da angiot

19.
Ars vet ; 27(2): 085-093, 2011.
Artigo em Português | VETINDEX | ID: vti-765108

Resumo

Devido à prevalência de cães portadores da doença degenerativa mixomatosa da válvula mitral (DMMVD) realizou-se uma investigação clínica da eficácia de diferentes protocolos terapêuticos a base de maleato de enalapril, furosemida, espironolactona e suas associações, em cães com DMMVD pertencentes à classe funcional II da insuficiência cardíaca congestiva (ICC). Para tanto, utilizaram-se 20 cães distribuídos em dois grupos (n=10), com o primeiro recebendo maleato de enalapril (0,5 mg/kg) e furosemida (2 mg/kg) e o segundo, maleato de enalapril associado à espironolactona (1 mg/kg) e furosemida, administrados uma vez ao dia durante 56 dias. Os cães foram avaliados em quatro momentos quanto aos sinais clínicos, avaliações radiográficas, eletrocardiográficas, ecodopplercardiográficas e aferição da pressão arterial. Entretanto, em relação aos parâmetros hematológicos e bioquímico-séricos, que incluíram mormente as concentrações séricas da enzima conversora da angiot

20.
Ars vet ; 26(3): 132-137, 2010.
Artigo em Português | VETINDEX | ID: vti-765094

Resumo

The cardiovascular response to acute normovolemic anemia is related to activation of compensatory mechanisms that can cause changes in the electrocardiogram. The electrocardiographic examination demonstrates the occurrence of arrhythmias and may suggest the presence of atrial and ventricular enlargement or myocardium hypoxia. The aim of this study is to describe cardiac rhythm, heart rate and ECG pattern in dogs undergoing acute normovolemic anemia. The dogs were submitted to computerized electrocardiography 15 minutes and 24 hours after induction of anemia and evaluated by Holter, with 24 hours of continuous electrocardiographic monitoring. Anemic dogs had no arrhythmias or premature ventricular and atrial complexes related to hypoxia and it were observed reductions in the incidence of sinus arrhythmia. Although there was no development of sinus tachycardia, there was a significant increase (P = 0.01) in heart rate (bpm) in both assessments made after installation of anemia (100.90 ± 23.1 to 132.50 ± 12.7 and 132.70 ± 23.9). The increased heart rate was linearly related to the fall in hematocrit (R2 = 0.27, P = 0.018). In addition, this study identified changes in the amplitude and duration of P wave and PR interval, without clinical significance because they were within the normal range for the specie. Therefore, dogs with acute normovolemic anemia and volemic reposition with

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA