Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Acta sci. vet. (Impr.) ; 50: Pub. 1897, 2022. ilus, tab
Artigo em Inglês | VETINDEX | ID: biblio-1414950

Resumo

Background: Cranial cruciate ligament failure is one of the leading causes of pelvic limb lameness in dogs and one of the most recommended treatments is tibial plateau leveling osteotomy (TPLO) surgery. However, this procedure may lead to some complications as fractures of the fibula, laceration in varying degrees of the popliteal vasculature and its branches, neuropraxia, neurotmeses, among others. The goals of this study were to compare the effectiveness of 8 methods used during TPLO, to prevent damage to the cranial tibial artery, fibula, tibial and fibular nerve (surgical compresses, specific surgical retractors I and II and an osteotomy technique variation). Materials, Methods & Results: A total of 40 canine cadavers weighing 25.9 ± 3.7 kg were submitted to TPLO. Animals were previously prepared with 1: 4 barium red latex solution, to provide radiopacity of arteries surrounding the knee (n = 80). TPLO was performed using 8 methods to protect the cranial tibial artery, fibula, and tibial and fibular nerves. Each method was used in one of the knees of 5 animals. The contralateral knee was maintained as a control (without protection). The knees were radiographed in orthogonal projections before and after the osteotomies and then anatomically dissected. The evaluated structures were photographed, and the images sent to four blind evaluators (visual macroscopy) to classify the possible injuries. The highest incidence of injuries was identified when protection methods were used. However, this difference was not significant (P > 0.05). No significant differences regarding efficacy were found between all 8 protection methods. Discussion: In this study, the total incidence of injuries following TPLO was 20% was much higher than that presented in the literature which indicates when considering only intraoperative injuries. The dogs cadavers tissue resistance and stiffened latex may have predisposed the osteotomy injury, as soft tissues with greater flexibility are less susceptible to trauma caused by the oscillatory saw. When compared to others cadaveric studies that also evaluated the efficacy of surgical dressings to protect the cranial tibial artery, during TPLO, we also find a higher incidence of damage. Maybe the limb's position was responsible for this difference, once in the after mentioned researches the limb was positioned suspended to simulate a dorsal decubitus position and we choose the limb position with the lateral face resting on the surface of the operating table, and this may have provided extra pressure from the structures towards the osteotomy saw, increasing the occurrence of those damages. Although the present study did not reveal a significant difference for the use of protection methods, we believe that the dimensions of the compresses used herein may have contributed to a higher incidence of injuries. They probably increased the tissue trauma needed for their allocation and led to a lower positioning accuracy for the isolation of these structures. Maybe for the same reason, the specific type II surgical retractor was the only shield that, observationally, did not increase the occurrence of injuries, once less dissection was required to allocate it. The difference in geometric dimensions between the retractors may justify the superiority of the retractor II, since it allows a more careful and apparently less traumatic allocation. Performing TPLO without adopting these protection methods did not lead to a higher risk of injury to the cranial tibial artery, fibula, and tibial and fibular nerves.


Assuntos
Animais , Cães , Osteotomia/métodos , Osteotomia/veterinária , Joelho de Quadrúpedes/cirurgia , Tíbia/cirurgia
2.
Acta cir. bras. ; 36(2): e360206, 2021. ilus, tab
Artigo em Inglês | VETINDEX | ID: vti-30547

Resumo

Purpose To evaluate clinical outcome following minimally invasive plate osteosynthesis (MIPO) associated with percutaneous transplantation of allogeneic adipose-derived mesenchymal stem cells (AD-MSC) at the tibial fracture site in dogs. Methods Thirty-six dogs presenting with nonarticular complete tibial fracture were included in this study. All fractures were treated by the same MIPO technique. The animals were divided in group 1 (n = 20) received a percutaneous application of 3 × 106 AD-MSC at the fracture site and group 2 (n = 16) did not receive any adjuvant treatment. Postoperative radiographic examinations were made at 15, 30, 60, 90 and 120 days. Results Fifty-eight percent of the patients were classified as skeletally immature. The median weight of the animals was 18.8 kg. The mean radiographic union time differed statistically between the AD-MSC group (28.5 days) and the control group (70.3 days). Sixty percent of dogs in group 1 and 56.25% of the group 2 were considered immature. Conclusions The use of allogeneic AD-MSC cell therapy and MIPO is a safe, viable and effective technique for promoting bone healing in nonarticular tibial fractures in dogs.(AU)


Assuntos
Animais , Cães , Células-Tronco Mesenquimais , Fixação Interna de Fraturas/veterinária , Lesões do Menisco Tibial/veterinária , Cicatrização
3.
Ci. Rural ; 51(4)2021. ilus, tab
Artigo em Inglês | VETINDEX | ID: vti-31163

Resumo

This study determined the canal flare index (CFI) of four dog breeds using two distinct femoral regions as a reference. Thirty-five radiographs of the hip joints of Golden Retrievers (GRG), German Shepherds (GSG), Labrador Retrievers (LRG), and Rottweilers (RG) of both sexes were used. Seventy experimental units were submitted to CFI calculation. Objective (CFIob) and subjective (CFIsub) values of the CFI of each experimental unit were determined according to the anatomical reference used for the calculation. A significant difference in the CFIob between the Golden Retriever and German Shepherd breeds (1.68 ± 0.16 and 1.49 ± 0.08), and in the CFIsub between Golden Retriever, German Shepherd, and Rottweiler breeds (2.09 ± 0.31, 1.86 ± 0.11, and 1.84 ± 0.18) was reported. The subjective form of measurement showed higher values than the objective form (GRG: 2.09 ± 0.31; GSG: 1.86 ± 0.11; LRG: 2.07 ± 0.12; RG: 1.84 ± 0.18). The CFI values of each breed were similar, suggesting a certain racial pattern. A significant difference in the interobserver assessment for both CFIsub and CFIob, in all races was observed. The CFI analysis identified morphological patterns of the proximal femur in the different races. Results indicated the need for standardization of the anatomical references used to calculate the CFI because there were statistical differences among the measurements among the observers.(AU)


Objetivou-se determinar o canal flare index (CFI) de quatro raças específicas de cães, utilizando-se duas regiões femorais distintas como referência. Foram analisadas 35 radiografias de articulações coxofemorais de cães das raças Golden Retriever (GGR), Pastor Alemão (GPA), Labrador Retriever (GLR) e Rottweiler (GR), de ambos os sexos, configurando 70 unidades experimentais submetidas ao cálculo do CFI. Determinaram-se os valores objetivo (CFIob) e subjetivo (CFIsub) do CFI de cada unidade experimental de acordo com a referência anatômica utilizada para o cálculo. Houve diferença significativa do CFIob entre as raças Golden Retriever e Pastor Alemão (1,68 ± 0,16 e 1,49 ± 0,08), e do CFIsub entre as raças Golden Retriever, Pastor Alemão e Rottweiler (2,09 ± 0,31, 1,86 ± 0,11 e 1,84 ± 0,18). A forma subjetiva de mensuração apresentou valores maiores que a forma objetiva (GGR: 2,09 ± 0,31; GPA: 1,86 ± 0,11; GLR: 2,07 ± 0,12; GR: 1,84 ± 0,18). Os valores de CFI de cada raça se apresentaram similares, sugerindo haver determinado padrão racial. Houve diferença significativa na avaliação interobservadores, tanto do CFIsub quanto CFIob, em todas as raças. A análise do CFI identificou padrões morfológicos do fêmur proximal nas diferentes raças. Os resultados indicaram a necessidade de padronização dos referenciais anatômicos utilizados para o cálculo do CFI, uma vez que houve relevância estatística entre as diferentes mensurações entre os observadores.(AU)


Assuntos
Animais , Cães , Artroplastia/instrumentação , Artroplastia/normas , Prótese de Quadril/estatística & dados numéricos , Prótese de Quadril/veterinária
4.
Ciênc. rural (Online) ; 51(09): 1-9, 2021. tab, ilus
Artigo em Inglês | VETINDEX | ID: biblio-1480209

Resumo

This study assessed radiographically changes in tibial alignment in the frontal and sagittal planes in dogs that underwent minimally invasive plate osteosynthesis (MIPO) without the aid of image intensifiers. Radiographs of dogs with complete non-articular tibial fractures submitted to MIPO were included and evaluated, without the aid of a transoperative image intensifier and / or an association of implants. The tibial mechanical angles (mMPTA, mMDTA, mCaPTA and mCrDTA) were measured by three evaluators. The data obtained were compared with results from previously published studies. Twenty-seven animals were included in the study. The mean and standard deviation of the angular changes were as follows: mMPTA, 2.54° ± 3.10 (-1.1º to 8.7º); mMDTA, 0.03º ± 0.16 (-3.44º to 0.79º); mCaPTA, 37º ± 4.29 (-6.23º to 14.87º); and mCrDTA, 8.25° ± 5.53 (-0.2º to 17.28º). There was a negative correlation between “mCaPTA” and “mCrDTA”. MIPO of the tibia without using image intensifiers and implant association can potentially cause angular changes, which can lead to clinically relevant deformities after bone healing.


Este estudo teve como objetivo avaliar radiograficamente as alterações no alinhamento da tíbia nos planos frontal e sagital em cães submetidos à osteossíntese minimamente invasiva com placa (MIPO) sem o auxílio de intensificadores de imagem. Foram incluídas e avaliadas radiografias de cães com fraturas completas da tíbia não articulares submetidos a MIPO, sem o auxílio de intensificador de imagem transoperatório e/ou associação de implantes. Os ângulos mecânicos tibiais (mMPTA, mMDTA, mCaPTA e mCrDTA) foram mensurados por três avaliadores. Os dados obtidos pela média de todas as avaliações foram comparados com resultados de estudos previamente publicados. Vinte e sete animais foram incluídos no estudo. A média e desvio padrão das alterações angulares foram os seguintes: mMPTA= 2,54° ± 3,10 (-1,1º a 8,7º); mMDTA= 0,03º ± 0,16 (-3,44º a 0,79º); mCaPTA= 37º ± 4,29 (-6,23º a 14,87º); e mCrDTA= 8,25° ± 5,53 (-0,2º a 17,28º). Houve uma correlação negativa entre “mCaPTA” e “mCrDTA”. A realização de MIPO em tíbia sem o uso de intensificadores de imagem e associação de implantes pode causar alterações angulares, o que pode levar a deformidades clinicamente relevantes após a cicatrização óssea.


Assuntos
Animais , Cães , Fraturas da Tíbia/complicações , Fraturas da Tíbia/diagnóstico , Fraturas da Tíbia/veterinária
5.
Ci. Rural ; 51(09): 1-9, 2021. tab, ilus
Artigo em Inglês | VETINDEX | ID: vti-32018

Resumo

This study assessed radiographically changes in tibial alignment in the frontal and sagittal planes in dogs that underwent minimally invasive plate osteosynthesis (MIPO) without the aid of image intensifiers. Radiographs of dogs with complete non-articular tibial fractures submitted to MIPO were included and evaluated, without the aid of a transoperative image intensifier and / or an association of implants. The tibial mechanical angles (mMPTA, mMDTA, mCaPTA and mCrDTA) were measured by three evaluators. The data obtained were compared with results from previously published studies. Twenty-seven animals were included in the study. The mean and standard deviation of the angular changes were as follows: mMPTA, 2.54° ± 3.10 (-1.1º to 8.7º); mMDTA, 0.03º ± 0.16 (-3.44º to 0.79º); mCaPTA, 37º ± 4.29 (-6.23º to 14.87º); and mCrDTA, 8.25° ± 5.53 (-0.2º to 17.28º). There was a negative correlation between “mCaPTA” and “mCrDTA”. MIPO of the tibia without using image intensifiers and implant association can potentially cause angular changes, which can lead to clinically relevant deformities after bone healing.(AU)


Este estudo teve como objetivo avaliar radiograficamente as alterações no alinhamento da tíbia nos planos frontal e sagital em cães submetidos à osteossíntese minimamente invasiva com placa (MIPO) sem o auxílio de intensificadores de imagem. Foram incluídas e avaliadas radiografias de cães com fraturas completas da tíbia não articulares submetidos a MIPO, sem o auxílio de intensificador de imagem transoperatório e/ou associação de implantes. Os ângulos mecânicos tibiais (mMPTA, mMDTA, mCaPTA e mCrDTA) foram mensurados por três avaliadores. Os dados obtidos pela média de todas as avaliações foram comparados com resultados de estudos previamente publicados. Vinte e sete animais foram incluídos no estudo. A média e desvio padrão das alterações angulares foram os seguintes: mMPTA= 2,54° ± 3,10 (-1,1º a 8,7º); mMDTA= 0,03º ± 0,16 (-3,44º a 0,79º); mCaPTA= 37º ± 4,29 (-6,23º a 14,87º); e mCrDTA= 8,25° ± 5,53 (-0,2º a 17,28º). Houve uma correlação negativa entre “mCaPTA” e “mCrDTA”. A realização de MIPO em tíbia sem o uso de intensificadores de imagem e associação de implantes pode causar alterações angulares, o que pode levar a deformidades clinicamente relevantes após a cicatrização óssea.(AU)


Assuntos
Animais , Cães , Fraturas da Tíbia/complicações , Fraturas da Tíbia/diagnóstico , Fraturas da Tíbia/veterinária
6.
Acta sci. vet. (Online) ; 46(supl): 1-4, 2018. ilus
Artigo em Português | VETINDEX | ID: vti-734034

Resumo

Background: Tibiotarsal joint luxations are mostly traumatic and due to automobile accidents. The arthrodesis of this joint is considered the final solution for trauma with ligament lesions without repair, luxations without possibility of joint recovery and chronic joint diseases. The direction to which the joint is dislocated is associated with the forces of trauma, and bilateral ligament injuries are not uncommon. However, the medial ligaments are more frequently injured. The aim of this study is to describe the performance of pantarsal arthrodesis using a customized titanium plate for application to the medial surface of the joint.Case: An undefined breed dog, weighing 21.5 kg, was attended at the Veterinary Hospital of the Federal University of Lavras (UFLA) with history of trauma and injury in the right pelvic limb. After physical and radiographic examinations it was diagnosed with an exposed luxation of the tibiotarsal joint and tissue loss in the region. The tibiotarsal region was cleaned and a bandage was made daily until the first surgical procedure, which occurred five days later. Initially, it was treated without success with the use of a transarticular external fixator1 . Subsequently, pantarsal arthrodesis was performed using a customized titanium angled plate (Made by a private manufacturer based on the functional angulation of the tibiotarsal joint of the contralateral limb). The joint was accessed for exposure of the distal portion of the tibia, tarsal and metatarsals bones. Wear of the articular surfaces was performed and then the customized angulation plate for pantarsal arthrodesis was placed on the medial side of the joint. Bicortical drillings were performed, starting with the proximal orifice. According to the holes of the plate, five 3.5 mm diameter screws1 (four at the distal tibia and one at the tarsus) and four 2.7 mm diameter screws were used in the metatarsal bones.[...](AU)


Assuntos
Animais , Adulto , Cães , Artrodese/veterinária , Placas Ósseas/veterinária , Tarso Animal/cirurgia , Tarso Animal/lesões , Titânio/uso terapêutico
7.
Acta sci. vet. (Impr.) ; 46(supl): 1-4, 2018. ilus
Artigo em Português | VETINDEX | ID: biblio-1457973

Resumo

Background: Tibiotarsal joint luxations are mostly traumatic and due to automobile accidents. The arthrodesis of this joint is considered the final solution for trauma with ligament lesions without repair, luxations without possibility of joint recovery and chronic joint diseases. The direction to which the joint is dislocated is associated with the forces of trauma, and bilateral ligament injuries are not uncommon. However, the medial ligaments are more frequently injured. The aim of this study is to describe the performance of pantarsal arthrodesis using a customized titanium plate for application to the medial surface of the joint.Case: An undefined breed dog, weighing 21.5 kg, was attended at the Veterinary Hospital of the Federal University of Lavras (UFLA) with history of trauma and injury in the right pelvic limb. After physical and radiographic examinations it was diagnosed with an exposed luxation of the tibiotarsal joint and tissue loss in the region. The tibiotarsal region was cleaned and a bandage was made daily until the first surgical procedure, which occurred five days later. Initially, it was treated without success with the use of a transarticular external fixator1 . Subsequently, pantarsal arthrodesis was performed using a customized titanium angled plate (Made by a private manufacturer based on the functional angulation of the tibiotarsal joint of the contralateral limb). The joint was accessed for exposure of the distal portion of the tibia, tarsal and metatarsals bones. Wear of the articular surfaces was performed and then the customized angulation plate for pantarsal arthrodesis was placed on the medial side of the joint. Bicortical drillings were performed, starting with the proximal orifice. According to the holes of the plate, five 3.5 mm diameter screws1 (four at the distal tibia and one at the tarsus) and four 2.7 mm diameter screws were used in the metatarsal bones.[...]


Assuntos
Animais , Adulto , Cães , Artrodese/veterinária , Placas Ósseas/veterinária , Tarso Animal/cirurgia , Tarso Animal/lesões , Titânio/uso terapêutico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA