Resumo
ABSTRACT Purpose To evaluate capsules formed by microtextured silicone implants with and without Parietex® mesh coverage histologically. Methods Sixty Wistar rats were divided in two groups (meshed and unmeshed). Each group was, then, divided into two subgroups for evaluation at 30 and 90 days. Capsules were analyzed based on hematoxylin and eosin (HE) and picrosirius staining. Results The number of fibroblasts, neutrophils and macrophages was similar among all subgroups. There was a higher lymphocyte reaction in the 30-day meshed group (p = 0.003). Giant cell reaction, granulation tissue and neoangiogenesis were similar among the subgroups. Synovial metaplasia was milder at 90-day in the unmeshed (p = 0.002) and meshed group (p < 0.001). Capsular thickness was significantly greater in the meshed samples (30-day p < 0.001 and 90-day p < 0.001). There was a similar amount of collagen types I and III in both groups. Conclusions The mesh-covered implants produced capsules similar to the microtextured ones when analyzing inflammatory variables. Synovial metaplasia was milder at 90 than at 30 days, and the capsular thickness was significantly greater in the meshed group. A similar amount of collagen types I and III was observed. Due to these characteristics, the mesh coverage did not seem to significantly affect the local inflammatory activity.
Assuntos
Animais , Feminino , Ratos , Silicones , Implantes de Mama/efeitos adversos , Poliésteres , Telas Cirúrgicas/efeitos adversos , Cápsulas , Colágeno , Ratos WistarResumo
Purpose To evaluate whether silicone foam implants have a different evolution pattern compared to conventional texture implants. Methods Fifty-eight female patients underwent surgery. They were divided into two groups (silicone foam Lifesil® and microtexturized silicone Lifesil®). The evolution was analyzed in postoperative consultations, with physical examination, photographic documentation and filling in a satisfaction questionnaire, in the postoperative period of one month, four months, one year and then annually, up to a maximum of 3 years of follow-up. Results There were no statistically significant differences in presence of rippling, stretch marks, breast ptosis, capsular contracture and quality of scars. There was a higher rate of patients who were very satisfied with the outcome 360 days after surgery in the group receiving silicone foam implants (p = 0.036). Conclusion In short time, silicone foam envelope implants proved to be as reliable as textured silicone envelope implants, making them an option for augmentation mammoplasty.(AU)
Assuntos
Humanos , Feminino , Benchmarking , Implante Mamário/métodos , Géis de Silicone/administração & dosagem , Mamoplastia/métodosResumo
A artroplastia total da articulação coxofemoral é a técnica cirúrgica mais efetiva para o tratamento da displasia coxofemoral canina grave. Na atualidade, o exame radiográfico é o método mais utilizado para se avaliar esse procedimento em cães, porém possui algumas limitações. Já o exame tomográfico por meio de tomografia computadorizada possibilita a aquisição de imagens sem sobreposições e, dessa forma, a determinação do posicionamento dos componentes protéticos com maior precisão. A presente pesquisa teve como objetivo avaliar, por meio de exames radiográficos e tomográficos, a utilização de uma prótese total modular híbrida da articulação coxofemoral desenvolvida e confeccionada no Brasil, aplicada experimentalmente em cães sadios. Foram utilizados seis cães esqueleticamente maduros, previamente submetidos ao procedimento cirúrgico da articulação coxofemoral esquerda. Os cães foram submetidos ao exame tomográfico aos 360 dias e três anos após a cirurgia. Todos os animais apresentaram bom posicionamento dos componentes protéticos e redução articular adequada. Ao exame tomográfico, entretanto, foram detectadas áreas de preenchimento irregular em alguns animais. Adicionalmente, o exame tomográfico permitiu a detecção e monitoração de áreas de reabsorção óssea ao redor do componente acetabular. Assim, o exame tomográfico mostrou-se útil na avaliação das articulações protéticas, com a vantagem de apresentar ótima definição das imagens e permitir quantificar alterações periprotéticas e mensurar relações articulares, fundamentais para o acompanhamento pós-cirúrgico tardio.(AU)
The total hip arthroplasty is the most effective surgical technique for the treatment of severe canine hip dysplasia. Currently, the radiographic examination is the most common method used to assess this procedure in dogs, but has some limitations. CT scan by computed tomography instead enables the acquisition of images without overlap, thereby determining the positioning of prosthetic components with greater accuracy. This research aimed to evaluate by radiography and CT scan examinations the use of a hybrid modular total hip prosthesis developed and made in Brazil, applied experimentally in healthy dogs. Six skeletally mature dogs, which previously underwent surgery on the left hip joint were used. The dogs underwent CT scan at 360 days and three years after surgery. All animals showed good positioning of prosthetic components, and proper joint reduction. In the CT scan, however, it was possible to detect irregular fill areas in some animals. In addition, CT scan allowed the detection and monitoring of areas of bone resorption around the acetabular component. Therefore, the CT scan was useful in the evaluation of prosthetic joints, with the advantage of optimum sharpness of the images and allowing for the possibility of quantifying peri-prosthetic changes and measure joint, fundamental relations for late postoperative follow-up.(AU)
Assuntos
Animais , Cães , Displasia Pélvica Canina/cirurgia , Artroplastia/veterinária , Próteses e Implantes/veterinária , Diagnóstico por Imagem/veterinária , Tomografia Computadorizada por Raios X/veterináriaResumo
A artroplastia total da articulação coxofemoral é a técnica cirúrgica mais efetiva para o tratamento da displasia coxofemoral canina grave. Na atualidade, o exame radiográfico é o método mais utilizado para se avaliar esse procedimento em cães, porém possui algumas limitações. Já o exame tomográfico por meio de tomografia computadorizada possibilita a aquisição de imagens sem sobreposições e, dessa forma, a determinação do posicionamento dos componentes protéticos com maior precisão. A presente pesquisa teve como objetivo avaliar, por meio de exames radiográficos e tomográficos, a utilização de uma prótese total modular híbrida da articulação coxofemoral desenvolvida e confeccionada no Brasil, aplicada experimentalmente em cães sadios. Foram utilizados seis cães esqueleticamente maduros, previamente submetidos ao procedimento cirúrgico da articulação coxofemoral esquerda. Os cães foram submetidos ao exame tomográfico aos 360 dias e três anos após a cirurgia. Todos os animais apresentaram bom posicionamento dos componentes protéticos e redução articular adequada. Ao exame tomográfico, entretanto, foram detectadas áreas de preenchimento irregular em alguns animais. Adicionalmente, o exame tomográfico permitiu a detecção e monitoração de áreas de reabsorção óssea ao redor do componente acetabular. Assim, o exame tomográfico mostrou-se útil na avaliação das articulações protéticas, com a vantagem de apresentar ótima definição das imagens e permitir quantificar alterações periprotéticas e mensurar relações articulares, fundamentais para o acompanhamento pós-cirúrgico tardio.(AU)
The total hip arthroplasty is the most effective surgical technique for the treatment of severe canine hip dysplasia. Currently, the radiographic examination is the most common method used to assess this procedure in dogs, but has some limitations. CT scan by computed tomography instead enables the acquisition of images without overlap, thereby determining the positioning of prosthetic components with greater accuracy. This research aimed to evaluate by radiography and CT scan examinations the use of a hybrid modular total hip prosthesis developed and made in Brazil, applied experimentally in healthy dogs. Six skeletally mature dogs, which previously underwent surgery on the left hip joint were used. The dogs underwent CT scan at 360 days and three years after surgery. All animals showed good positioning of prosthetic components, and proper joint reduction. In the CT scan, however, it was possible to detect irregular fill areas in some animals. In addition, CT scan allowed the detection and monitoring of areas of bone resorption around the acetabular component. Therefore, the CT scan was useful in the evaluation of prosthetic joints, with the advantage of optimum sharpness of the images and allowing for the possibility of quantifying peri-prosthetic changes and measure joint, fundamental relations for late postoperative follow-up.(AU)
Assuntos
Animais , Cães , Artroplastia/veterinária , Displasia Pélvica Canina/cirurgia , Próteses e Implantes/veterinária , Diagnóstico por Imagem/veterinária , Tomografia Computadorizada por Raios X/veterináriaResumo
Infecções dos sítios cirúrgicos são comuns, mesmo em pacientes utilizando antibioticoterapia profilática. As infecções do sítio cirúrgico são um dos principais contribuintes para a morbidade e mortalidade nos cuidados pós-operatórios. Os biofilmes são um grupo complexo de células microbianas que aderem a matriz de exopolissacarídeos presente na superfície de dispositivos médicos. As infecções associadas ao biofilme nos dispositivos médicos representam um grave problema para a saúde pública e afetam a função do dispositivo. A infecção no implante mamário de silicone ocorre em 7 a 24% das reconstruções mamárias. Estas infecções ocasionam morbidade e possível diminuição de qualidade de vida para os pacientes, além de altos custos com seu tratamento. Os anestésicos locais são utilizados comumente como agente para analgesia pós-operatória e tem um baixo custo, porém sua ação como agente microbicida ainda é controversa. Objetivo: Avaliar o efeito bactericida de diferentes soluções para Staphylococcus aureus e Staphylococcus epidermidis associadas infecção de feridas cirúrgicas e próteses de silicone in vitro. Material e métodos: Para este estudo, foram avaliados os seguintes microrganismos: S. aureus e S. epidermidis. Foi realizada análise com suspensões em solução salina estéril com os microrganismos. O estudo foi realizado em duas etapas: primeiro o teste de difusão em ágar e posterirormente a análise das próteses de silicone. Na primeira etapa, para o teste de difusão em ágar (avaliação das bactérias em estado planctônico), as suspensões com os microrganismos foram inoculadas com auxílio de swab estéril na superfície do ágar sangue. Na sequência, foram confeccionados orifícios equidistantes medindo 3mm de diâmetro e 3mm de profundidade no ágar sangue. Um orifício foi preenchido apenas com 1 gota da solução salina, outro com 1 gota da solução de com antisséptico, outro com 1 gota de Lidocaína pura, outro com 1 gota de solução de Lidocaína e outro com 1 gota da solução com antibiótico. Na segunda etapa, foram utilizadas 36 próteses de silicones (avaliação das bactérias em estado séssil), as quais foram divididos em 3 grupos: próteses contaminadas pelas bactérias e que não receberam tratamento; próteses contaminadas pelas bactérias que receberam tratamento antes da contaminação; e próteses contaminadas pelas bactérias que receberam tratamento após a contaminação. Os tratamentos foram realizados com clorexidina, solução de lidocaína, lidocaína pura e com solução de antibióticos (cefazolina e gentamicina). A incubação foi de 1 semana. As próteses foram semeadas por rolamento em meio de cultura ágar sangue, o qual foi incubado por 48 horas e avaliada a área com formação de colônias através de programa de análise de imagem. Resultados: As placas testadas com solução de lidocaína e a lidocaína pura não apresentaram halo de inibição. A solução de antibióticos apresentou os maiores halos de inibição em todas as bactérias testadas. Na pré-lavagem, não houve crescimento de S. epidermidis com solução de antibióticos. Na lavagem pós-contaminação, não houve crescimento de nenhuma das bactérias com a solução de antibióticos. Na lavagem pós-contaminação, houve diminuição da densidade de colonização com a clorexidina e ausência de crescimento de S. aureus com lidocaína pura e solução de lidocaína. Conclusão: A solução de antibióticos se mostrou uma boa alternativa para o controle, principalmente S. epidermidis, na lavagem pré e pós-contaminação nas próteses de silicone. A lidocaína (pura ou em solução) embora não tenham inibido o crescimento bacteriano nas placas com meio de cultura, foi capaz de diminuir a colonização por S. aureus na lavagem pós-contaminação, mostrando que pode ser utilizada como tratamento adjuvante nestes casos.
Surgical site infections are common, even in patients using prophylactic antibiotic therapy. Surgical site infections are a major contributor to morbidity and mortality in postoperative care. Biofilms are a complex group of microbial cells that adhere to the exopolysaccharide matrix present on the surface of medical devices. Infections associated with biofilm in medical devices pose a serious public health problem and affect the function of the device. Infection in the silicone breast implant occurs in 7 to 24% of breast reconstructions. These infections cause morbidity and possible decrease in quality of life for patients, in addition to high costs with their treatment. Local anesthetics are commonly used as an agent for postoperative analgesia and have a low cost, but their action as a microbicidal agent is still controversial. Objective: To evaluate the bactericidal effect of different solutions for Staphylococcus aureus and Staphylococcus epidermidis associated with surgical wound infection and silicone prostheses in vitro. Material and methods: For this study, the following microrganisms were evaluated: S. aureus and S. epidermidis. Analysis was carried out with suspensions in sterile saline solution with the microrganisms. The study was carried out in two stages: first the agar diffusion test and then the analysis of silicone prostheses. In the first stage, for the agar diffusion test (evaluation of bacteria in planktonic state), the suspensions with the microrganisms were inoculated with the aid of a sterile swab on the surface of the blood agar. Then, equidistant holes were made measuring 3mm in diameter and 3 mm deep in the blood agar. One orifice was filled with 1 drop of saline only, another with 1 drop of antiseptic solution, another with 1 drop of pure Lidocaine, another with 1 drop of Lidocaine solution and another with 1 drop of the antibiotic solution. In the second stage, 36 silicone prostheses (assessment of bacteria in sessile state) were used, which were divided into 3 groups: prostheses contaminated by the bacteria and which did not receive treatment; prostheses contaminated by bacteria and which received treatment before contamination; and prostheses contaminated by bacteria and which received treatment after contamination. Treatments were performed with chlorhexidine, lidocaine solution, pure lidocaine and antibiotics solution (cefazolin and gentamicin). The incubation was 1 week. The prostheses were sown by rolling in a blood agar culture medium, which was incubated for 48 hours and the area with colony formation was evaluated using an image analysis program. Results: The plates tested with lidocaine solution and pure lidocaine did not present an inhibition halo. The antibiotic solution showed the greatest inhibition halos in all the tested bacteria. In the prewash, there was no growth of S. epidermidis with antibiotic solution. In the post-contamination wash, none of the bacteria grew with the antibiotic solution. In post-contamination washing, there was a decrease in the density of colonization with chlorhexidine and absence of growth of S. aureus with pure lidocaine and lidocaine solution. Conclusion: The antibiotic solution proved to be a good alternative for the control, mainly S. epidermidis, in the pre and post-contamination washing in silicone prostheses. Lidocaine (pure or in solution) although it did not inhibit bacterial growth on plates with culture medium, was able to decrease colonization by S. aureus in post-contamination washing, showing that it can be used as an adjuvant treatment in these cases.
Resumo
PURPOSE:To investigate the osseointegration properties of prototyped implants with tridimensionally interconnected pores made of the Ti6Al4V alloy and the influence of a thin calcium phosphate coating.METHODS:Bilateral critical size calvarial defects were created in thirty Wistar rats and filled with coated and uncoated implants in a randomized fashion. The animals were kept for 15, 45 and 90 days. Implant mechanical integration was evaluated with a push-out test. Bone-implant interface was analyzed using scanning electron microscopy.RESULTS:The maximum force to produce initial displacement of the implants increased during the study period, reaching values around 100N for both types of implants. Intimate contact between bone and implant was present, with progressive bone growth into the pores. No significant differences were seen between coated and uncoated implants.CONCLUSION:Adequate osseointegration can be achieved in calvarial reconstructions using prototyped Ti6Al4V Implants with the described characteristics of surface and porosity.(AU)
Assuntos
Animais , Ratos , Osseointegração , Titânio , Próteses e Implantes , Materiais Biocompatíveis , Cerâmica , Crânio/lesões , Crânio/transplanteResumo
PURPOSES: To evaluate whether polyurethane foam leads more intense foreign-body reaction than silicone foam. To compare the vascularization of the capsules surrounding the foam implants. To investigate if the capsule of polyurethane foam implanted has greater amount of collagen than that of silicone foam. METHODS: Sixty-four young male Wistar rats were allocated into two groups: polyurethane foam and silicone foam. Subcutaneous discs were implanted into the dorsum of the animals in both groups. The capsules were assessed 28 days, two months, three months and six months postoperatively. Microscopic analysis with H&E stain was performed to evaluate the acute and chronic inflammatory process, foreign-body reaction and neovascularization. The analysis with picrosirius red was performed using the ImageProPlus software, to measure the number of vessels and collagen types I and III. RESULTS: There were no statistical differences between the two groups regarding the acute and chronic inflammatory processes. All rats from the polyurethane group, in all times, exhibited moderate or intense foreign-body reaction, with statistic significant difference (p=0.046) when compared with the silicone group, in which the reaction was either mild or nonexistent at two months. Vascular proliferation was significantly different between the groups at 28 days (p=0.0002), with the polyurethane group displaying greater neovascularization with H&E stain. Similar results were obtained with picrosirius red, which revealed in the polyurethane group a much greater number of vessels than in the silicone group (p=0.001). The collagen area was larger in the polyurethane group, significantly at 28 days (p=0.001) and at two months (p=0.030). CONCLUSIONS: Polyurethane foam elicited more intense foreign-body reaction when compared with silicone foam. The number of vessels was higher in the capsules of the polyurethane foam implants 28 days after the operation. The capsule of the polyurethane foam implants showed a greater amount of collagen than that of the silicone foam implants.(AU)
OBJETIVOS: Avaliar, em relação ao uso de próteses, se a espuma de poliuretano apresenta maior reação de corpo estranho no organismo ao ser comparada com a espuma de silicone. Se há diferenças na vascularização das cápsulas formada ao redor das duas espumas implantadas. Se as cápsulas dos implantes de espuma de poliuretano apresentam quantidade maior de fibras colágenas ao serem comparadas com as da espuma de silicone. MÉTODOS: Utilizou-se 64 ratos albinos da linhagem Wistar, distribuídos em dois grupos de 34, grupo espuma de poliuretano e grupo espuma de silicone e receberam implantes discóides subcutâneos em seu dorso. Foram analisadas as cápsulas peri-implante com 28 dias, dois, três e seis meses após a introdução. A análise microscópica com H&E considerou as variáveis: inflamação aguda, inflamação crônica, reação de corpo estranho e neoformação vascular. A análise da coloração com picrosirius-red usando ImageProPlus considerou o número de vasos e colágeno tipo I e tipo III. RESULTADOS: Em relação à inflamação aguda e crônica, não foram encontradas diferenças estatísticas nos dois grupos. Todos os animais do grupo poliuretano, em todos os momentos, apresentaram reação de corpo estranho moderada ou intensa e foi encontrada diferença estatística significativa (p=0,046) ao serem comparados com o grupo silicone, cuja reação era ausente ou discreta aos dois meses. A neoformação vascular apresentou diferenças significativas nos dois grupos, aos 28 dias (p=0,0002); o grupo poliuretano com H&E apresentava quantidade maior de vasos neoformados e o mesmo ocorrendo com o picrosirius, cujo número de vasos era maior que no grupo silicone (p=0,001). A área de colágeno em todos os momentos foi maior no grupo poliuretano, sendo significativa com 28 dias (p=0,001) e com dois meses (p=0,030). CONCLUSÕES: A espuma de poliuretano apresentou maior reação de corpo estranho no organismo do que a espuma de silicone. A quantidade de vasos foi maior na cápsula da espuma de poliuretano com 28 dias após o implante. Aos 28 dias as cápsulas dos implantes de espuma de poliuretano apresentaram quantidade significativamente maior de colágeno do que as de espuma de silicone.(AU)
Assuntos
Animais , Ratos , Silicones/análise , Poliuretanos/análise , Corpos Estranhos/complicações , Rejeição de Enxerto , Ratos/fisiologia , Próteses e ImplantesResumo
Purpose: To evaluate the effects of biliary stenting in rats through analysis of collagen and elastin deposition in the bile ducts. Methods: Twenty male rats underwent midline laparotomy, duodenotomy and transampullary stenting of the common bile duct with a 22Fr plastic stent. Animals were randomized in 4 groups, with 5 components in each: (I) control, (II) biliary stenting for 7 days, (III) biliary stenting for 14 days, and (IV) biliary stenting for 30 days. Sections of the common bile duct were stained using Hematoxylin Eosin; Sirius Red to quantitate the amount of collagen present; and Weigert's Resorcin-fuchsin to quantitate the amount of elastin present. Results: The percentage of area stained for collagen was 13.4; 21.5; 29.5 and 32.8, for groups I to IV, respectively. The percentage of area stained for elastin fibers was 7.0; 5.2; 4.0 and 2.9, for groups I to IV, respectively. Collagen/Elastin ratio was 2.4; 5.1; 11.0 and 14.4 for groups I to IV, respectively. Conclusions: The biliary stenting leads to collagen and elastin deposition in the bile ducts; and collagen deposition and collagen/elastin ratio are proportional to the period of stenting.(AU)
Objetivo: Avaliar os efeitos da colocação de prótese biliar em ratos, analisando a deposição de colágeno e elastina no hepatocolédoco. Métodos: Vinte ratos machos foram submetidos à laparotomia mediana, duodenotomia e colocação transpapilar de uma prótese plástica 22Fr no hepatocolédoco. Os animais foram randomizados em 4 grupos, com cinco componentes cada: (I) controle, (II) prótese biliar por 7 dias, (III) prótese biliar durante 14 dias e (IV) prótese biliar por 30 dias. Cortes do hepatocolédoco foram corados com Hematoxilina Eosina; Sirius Red para quantificar o colágeno; e Resorcina-fucsina de Weigert para quantificar a elastina. Resultados: A porcentagem de área corada para colágeno foi de 13,4; 21,5; 29,5 e 32,8 para os grupos I a IV, respectivamente. A porcentagem de área corada para fibras de elastina foi de 7,0; 5,2; 4,0 e 2,9, para os grupos I a IV, respectivamente. A razão colágeno / elastina foi de 2,4, 5,1, 11,0 e 14,4 para os grupos I a IV, respectivamente. Conclusões: O implante da prótese biliar leva à deposição de colágeno e elastina nos ductos biliares; e a deposição de colágeno e a relação colágeno / elastina são proporcionais ao tempo de permanência da prótese.(AU)
Assuntos
Animais , Masculino , Ratos , Próteses e Implantes/efeitos adversos , Colágeno , Elastina , Ducto Colédoco/cirurgia , Ducto Colédoco/patologia , RatosResumo
Há muito que se estudam métodos e materiais reparadores de córnea, em busca de uma melhor reposição tecidual e, principalmente, manutenção ou recuperação da visão. A pesquisa de novos biomateriais tem permitido produzir próteses capazes de desempenhar a função requerida, sem reação importante. Conhecendo-se os bons resultados obtidos com a utilização da poliuretana vegetal derivada de óleo de mamona (Ricinus communis L ) em vários procedimentos, estudou-se sua implantação, em forma de membrana, na córnea, objetivando oferecer novo material para a reparação de lesões corneanas e a confecção de ceratopróteses biologicamente inertes. Utilizaram-se 28 coelhos, divididos em dois grupos (G 1 e G2) e estes em subgrupos para avaliações de implantes lamelares e interlamelares aos 2, 7, 15, 30, 60 e 120 dias, e implantes penetrantes, aos 2, 7,15, 30 e 60 dias de pós-operatório. Estudaram-se parâmetros como neovascularização, inflamação, transparência de córneas e implantes, bem como a aderência e viabilidade destes, através de exames oculares, e histopatológicos à microscopia óptica. Observou-se reação inflamatória branda em todos os períodos. Os implantes lamelares e penetrantes permitiram reparação da córnea e manutenção da integridade dos globos oculares, embora sofressem deiscência entre 5 e 28 dias de pós-operatório. Concluiu-se pela boa biocompatibilidade do material e pela possibilidade de empregar-se o polímero na reparação corneana e, possivelmente, em ceratopróteses.(AU)
Assuntos
Animais , Carbamatos/administração & dosagem , Próteses e Implantes/veterinária , Córnea/cirurgia , Coelhos/cirurgiaResumo
Os aloenxertos, são retirados de fontes naturais e são utilizados em cirurgias ortopédicas em humanos e em animais há muitos anos. Desde 1952 centenas de cirurgias ortopédicas foram realizadas com sucesso usando-se tecidos e materiais doados de banco de ossos. O propósito do presente estudo é verificar o tempo de absorção, através de exames radiográficos, de parafusos confeccionados com cortical óssea bovina, inserida no tubérculo maior do úmero de sete cães, em comparação com parafusos de aço. Os resultados demonstraram que o parafuso de cortical bovino foi incorporado entre um período de 30 a 60 dias sem reação periostal exuberante.(AU)
Assuntos
Animais , Bovinos , Cães , Transplante Homólogo/veterinária , Osso e Ossos/cirurgia , Próteses e Implantes/veterinária , CãesResumo
Foram realizadas duas cirurgias de prótese total da articulação coxofemoral em cão. Em um caso observou-se luxação caudal da prótese 72 horas após a cirurgia, que foi reduzida pelo método fechado, mantendo-se bandagem de Ehmer por 15 dias.O segundo caso evoluiu favoravelmente sem complicações pós-operatórias.Os dois pacientes foram avaliados periodicamente por 18 meses, mostrando desempenho clínico satisfatório, o que mostra a eficiência da técnica.(AU)
Two canine total hip replacements were performed. In one case, caudal luxation was observed 72 hours after the surgery, and it was treated by the closed reduction method, maintaining the Ehmer's sling for 15 days. The second case evoluted favourably without any postsurgical complication. Both patients were periodically evaluated during the 18 months that followed the surgery, showing a satisfactory clinical performance, that suggests the efficacy of the surgical technique.(AU)
Assuntos
Animais , Masculino , Displasia Pélvica Canina , Osteoartrite , Cirurgia Geral , Cães , Próteses e ImplantesResumo
PURPOSE: Observing the effects produced by the prosthesis of polypropylene in the pré-peritoneal space in dogs METHODS: 10 adult cross-bread dogs (n=10) have been put trough bilateral inguinotomy where prosthesis was put on one of its sides. In the contra-lateral region, the procedure was the same, but without the use of prosthesis, serving as a control. After 30 days the animals had been submitted to a laparoscopic technique and a macroscopic evaluation was made via intraperitoneal besides being through a biopsy of fragments of the peritoneum to record histological alterations of the two inguinal regions. RESULTS: Three of the animals presented adhesions in the local of the polypropylene prosthesis was placed. No animal presented adhesion in the local without prosthesis. The microscopically alterations in side A (with prosthesis) were characterized by the proliferation of dense fibrous conjunctive tissue, besides the lack of presence of giant multinuclear showing a light inflammatory reaction. CONCLUSION: The prosthesis of polypropylene induce the formation of adhesions, when placed in the pre-peritoneal space of dogs
OBJETIVO: Observar os efeitos produzidos pela prótese de polipropileno no espaço pré-peritoneal. MÉTODOS: 10 cães (n=10), adultos e sem raça definida, foram submetidos a inguinotomia bilateral, nas quais se colocou uma prótese em um dos lados. Na região contralateral, o procedimento foi o mesmo, sem a colocação da prótese, servindo como controle. Após 30 dias os animais foram submetidos a uma videolaparoscopia e foi realizada a avaliação macroscópica por via intraperitoneal, além do registro das alterações histológicas das duas regiões inguinais. RESULTADOS: Três (03) animais apresentaram aderências epiplóicas no local de implantação da prótese de polipropileno. Nenhum animal apresentou aderência no lado B (sem prótese). As alterações microscópicas no lado A (com prótese) caracterizaram-se pela proliferação de tecido conjuntivo fibroso denso, além da escassa presença de células gigantes multinucleadas, comprovando uma reação inflamatória de leve intensidade. CONCLUSÃO: A prótese de polipropileno induz a formação de aderências em 30% dos animais, quando colocada no espaço pré-peritoneal em cães.