Resumo
Hydroxyapatite, chitosan, and carbon nanotube composite biomaterial were developed to improve bone healing. Previous studies suggested that a combination of biomaterials and mesenchymal stem cells (MSCs) can potentially help promote bone regeneration. In the present study, we first developed hydroxyapatite, chitosan, and carbon nanotube composite biomaterial. Then, the effect of different concentrations of the extract on the viability of Vero cells (ATCC CCL-81) and MSCs obtained from sheep bone marrow using methylthiazol tetrazolium (MTT) and propidium iodide (PI) assays were evaluated. The biomaterial group demonstrated an absence of cytotoxicity, similar to the control group. Samples with 50% and 10% biomaterial extract concentrations showed higher cell viability compared to samples from the control group (MTT assay). These results suggest that the presence of this composite biomaterial can be used with MSCs. This study also concluded that hydroxyapatite, chitosan, and carbon nanotube composite biomaterial were not cytotoxic. Therefore, these could be used for performing in vivo tests.(AU)
O compósito à base de hidroxiapatita, quitosana e nanotubo de carbono foi desenvolvido com o intuito de auxiliar na consolidação óssea. Estudos anteriores sugerem que a combinação de substitutos ósseos e células-tronco mesenquimais (CTM) podem auxiliar a potencializar e promover a regeneração óssea. No presente estudo, o biomaterial foi desenvolvido e a viabilidade e a citotoxicidade de células Vero (ATCC CCL-81) e CTM obtidas de medula óssea provenientes de ovinos utilizando ensaios metil-tiazol-tetrazólio, MTT e iodeto de propídeo (PI) foram avaliadas em diferentes concentrações de extrato desse compósito. O compósito demonstrou ausência de citotoxicidade com comportamento semelhante ao grupo controle. Amostras com 50% e 10% de concentração de extrato do compósito mostraram resultados maiores comparados ao grupo controle (ensaio MTT). Esses resultados também sugerem que a presença do biomaterial pode ser utilizada em associação a CTM. Assim, esse estudo conclui que o compósito apresentado de hidroxiapatita, quitosana e nanotubo de cabono não foi considerado citotóxico e pode ser utilizado em teste in vivo.(AU)
Assuntos
Animais , Materiais Biocompatíveis , Durapatita , Quitosana , Citotoxicidade Imunológica , Nanotubos de Carbono , Células-Tronco MesenquimaisResumo
Hydroxyapatite, chitosan, and carbon nanotube composite biomaterial were developed to improve bone healing. Previous studies suggested that a combination of biomaterials and mesenchymal stem cells (MSCs) can potentially help promote bone regeneration. In the present study, we first developed hydroxyapatite, chitosan, and carbon nanotube composite biomaterial. Then, the effect of different concentrations of the extract on the viability of Vero cells (ATCC CCL-81) and MSCs obtained from sheep bone marrow using methylthiazol tetrazolium (MTT) and propidium iodide (PI) assays were evaluated. The biomaterial group demonstrated an absence of cytotoxicity, similar to the control group. Samples with 50% and 10% biomaterial extract concentrations showed higher cell viability compared to samples from the control group (MTT assay). These results suggest that the presence of this composite biomaterial can be used with MSCs. This study also concluded that hydroxyapatite, chitosan, and carbon nanotube composite biomaterial were not cytotoxic. Therefore, these could be used for performing in vivo tests.(AU)
O compósito à base de hidroxiapatita, quitosana e nanotubo de carbono foi desenvolvido com o intuito de auxiliar na consolidação óssea. Estudos anteriores sugerem que a combinação de substitutos ósseos e células-tronco mesenquimais (CTM) podem auxiliar a potencializar e promover a regeneração óssea. No presente estudo, o biomaterial foi desenvolvido e a viabilidade e a citotoxicidade de células Vero (ATCC CCL-81) e CTM obtidas de medula óssea provenientes de ovinos utilizando ensaios metil-tiazol-tetrazólio, MTT e iodeto de propídeo (PI) foram avaliadas em diferentes concentrações de extrato desse compósito. O compósito demonstrou ausência de citotoxicidade com comportamento semelhante ao grupo controle. Amostras com 50% e 10% de concentração de extrato do compósito mostraram resultados maiores comparados ao grupo controle (ensaio MTT). Esses resultados também sugerem que a presença do biomaterial pode ser utilizada em associação a CTM. Assim, esse estudo conclui que o compósito apresentado de hidroxiapatita, quitosana e nanotubo de cabono não foi considerado citotóxico e pode ser utilizado em teste in vivo.(AU)
Assuntos
Animais , Materiais Biocompatíveis , Durapatita , Quitosana , Citotoxicidade Imunológica , Nanotubos de Carbono , Células-Tronco MesenquimaisResumo
The aim of this study was to analyze the biological behavior and osteogenic potential of magnesium (Mg) substituted hydroxyapatite (HA) microspheres, implanted in a critical bone defect, considering that this ion is of great clinical interest, since it is closely associated with homeostasis and bone mineralization. For the purpose of this study, 30 rats were used to compose three experimental groups: GI - bone defect filled with HA microspheres; GII - bone defect filled with HA microspheres replaced with Mg; GIII - empty bone defect; evaluated at biological points of 15 and 45 days. The histological results, at 15 days, showed, in all the groups, a discrete chronic inflammatory infiltrate; biomaterials intact and surrounded by connective tissue; and bone neoformation restricted to the borders. At 45 days, in the GI and GII groups, an inflammatory response of discrete granulomatous chronic type was observed, and in the GIII there was a scarce presence of mononuclear inflammatory cells; in GI and GII, the microspheres were seen to be either intact or fragmented, surrounded by fibrous connective tissue rich in blood vessels; and discrete bone neoformation near the edges and surrounding some microspheres. In GIII, the mineralization was limited to the borders and the remaining area was filled by fibrous connective tissue. It was concluded that the biomaterials were biocompatible and osteoconductive, and the percentage of Mg used as replacement ion in the HA did not favor a greater bone neoformation in relation to the HA without the metal.(AU)
O objetivo deste estudo foi analisar o comportamento biológico de microesferas de hidroxiapatita (HA) substituída com magnésio (Mg) durante o reparo de defeito ósseo crítico, tendo em vista que este íon é de grande interesse clínico, pois está intimamente associado à homeostasia e à mineralização óssea. Para tanto, utilizou-se 30 ratos para compor três grupos experimentais: GI - defeito ósseo preenchido com microesferas de HA; GII - defeito ósseo preenchido com microesferas de HA substituída com Mg; GIII (controle) - defeito ósseo vazio; avaliados nos pontos biológicos de 15 e 45 dias. Os resultados histológicos evidenciaram, aos 15 dias, discreto infiltrado inflamatório crônico e neoformação óssea restrita às bordas, em todos os grupos. Nos grupos GI e GII, os biomateriais mantiveram-se íntegros e circundados por tecido conjuntivo frouxo. Aos 45 dias, notou-se resposta inflamatória do tipo crônica granulomatosa discreta nos grupos GI e GII, e no GIII presença escassa de células inflamatórias mononucleares. As microesferas implantadas no GI e GII mantiveram-se, em sua maioria, íntegras e envolvidas por tecido conjuntivo fibroso. Notou-se discreta neoformação óssea próxima às bordas e circunjacente a algumas microesferas. No GIII, a mineralização limitou-se às bordas e a área remanescente foi preenchida por tecido conjuntivo fibroso. Conclui-se que os biomateriais foram biocompatíveis, bioativos, osteocondutores e apresentaram biodegradação lenta, indicando seu grande potencial para em aplicações clínica como biomaterial de preenchimento.(AU)
Assuntos
Animais , Ratos , Durapatita , Magnésio , Regeneração Óssea , Materiais BiocompatíveisResumo
A não união óssea é uma complicação ortopédica que ocorre normalmente devido à instabilidade da fratura em decorrência de uma escolha de fixação inadequada ou inapropriada, suprimento sanguíneo deficiente, osteomielite e afastamento excessivo dos fragmentos; sendo mais comumente em cães de raças pequenas e miniatura; e de maior ocorrência em regiões distais de rádio, ulna, tíbia e fíbula. Este trabalho relata a utilização da associação entre Hidroxiapatita e Plasma Rico em Plaqueta no tratamento de uma não união óssea de rádio e ulna e esclarece os benefícios desses biomateriais no processo de regeneração do tecido ósseo. O presente trabalho tem por objetivo relatar o caso de um canino com não união óssea de rádio/ulna devido ao alinhamento inadequado dos fragmentos ósseos no tratamento conservador com bandagem, proporcionando instabilidade do foco da fratura. O tratamento cirúrgico consistiu na colocação de uma placa óssea e enxertia com Hidroxiapatita e Plasma Rico em Plaqueta para melhor regeneração óssea. A utilização de tais biomateriais no tratamento da não união foi benéfica para a formação do calo ósseo primário, não produzindo efeitos adversos para o paciente. A partir desse resultado pode-se concluir que, a utilização desses biomateriais e enxertia precisa ser mais bem estudada e aprimorada na reparação óssea de uma não união, visto que, a aplicabilidade dessa associação mostrou-se um método eficiente, não apresentando sinais de infecção e nem evidência de rejeição.(AU)
Bone nonunion is an orthopedic complication that usually occurs due to fracture instability as a result of an inadequate or inappropriate choice of fixation, deficient blood supply, osteomyelitis, and excessive removal of fragments; which is more commonly seen in small and miniature breeds; and more frequent in the distal regions of radius, ulna, tibia, and fibula. This paper reports on the use of the association between Hydroxyapatite and Platelet-Rich Plasma in the treatment of a radius and ulna nonunion and clarifies the benefits of these biomaterials in the bone tissue regeneration process. This study reports the case of a dog presenting nonunion of radius and ulna bone due to inadequate alignment of bone fragments in a conservative treatment with bandage, providing instability of the fracture focus. The surgical treatment consisted of placing a bone plate and grafting with Hydroxyapatite and Platelet-Rich Plasma for better bone regeneration. The use of such biomaterials in the treatment of nonunion injuries was beneficial for the formation of the primary bone callus, without producing adverse effects for the patient. From this result, it can be concluded that the use of these biomaterials and grafting needs to be further studied and improved for use in bone repair of nonunion cases, since the applicability of this association proved to be an efficient method, with no signs of infection or evidence of rejection.(AU)
Ausencia de unión ósea es uma complicación ortopédica que normalmente ocurre debido a la instabilidade de la fractura como resultado de uma elección de fijación inadecuada o inapropriada, aporte sanguíneo deficiente, osteomielitis y remoción excessiva de fragmentos; que se observa com mayor frecuencia en perros de razas pequeñas y miniaturas; y más frecuente em regiones distales de radio, cúbito, tíbia y peroné. Este artículo informa sobre el uso de la asociación de Hidroxiapatita y Plasma rico en plaqueta en el tratamiento de ausencia de unión del radio e el cúbito, y aclara los benefícios de esos biomateriales en el processo de regeneración del tejido ósseo. Esa investigación ha tenido como objetivo reportar el caso de un perro sin unión de radio / cúbito por alineación inadecuada de fragmentos óseos en tratamiento conservador con vendaje, proporcionando inestabilidad del foco de la fractura. El tratamiento quirúrgico consistió en la colocación de una placa ósea e injerto con Hidroxiapatita y Plasma rico en plaqueta para uma mejor regeneración ósea. El uso de tales biomateriales en el tratamiento de ausencia de unión ha sido beneficioso para la formación del callo óseo primario, sin producir efectos adversos para el paciente. A partir de ese resultado se puede concluir que, el uso de esos biomateriales e injertos necesitan ser mejor estudiado y mejorado en la reparación de ausencia ósea, ya que la aplicabilidad de esa asociación demostró ser um método eficaz, sin presentar signos de infección y evidencia de rechazo.(AU)
Assuntos
Animais , Regeneração Óssea/efeitos dos fármacos , Cães/lesões , Fraturas Ósseas/veterinária , Plasma Rico em Plaquetas/efeitos dos fármacos , Fraturas do Punho/tratamento farmacológico , Durapatita/químicaResumo
Purpose:To analyze, histomorphologically, the influence of the geometry of nanostructured hydroxyapatite and alginate (HAn/Alg) composites in the initial phase of the bone repair.Methods:Fifteen rats were distributed to three groups: MiHA - bone defect filled with HAn/Alg microspheres; GrHA - bone defect filled with HAn/Alg granules; and DV - empty bone defect; evaluated after 15 days postoperatively. The experimental surgical model was the critical bone defect, ≅8.5 mm, in rat calvaria. After euthanasia the specimens were embedded in paraffin and stained with hematoxylin and eosin, picrosirius and Masson-Goldners trichrome.Results:The histomorphologic analysis showed, in the MiHA, deposition of osteoid matrix within some microspheres and circumjacent to the others, near the bone edges. In GrHA, the deposition of this matrix was scarce inside and adjacent to the granules. In these two groups, chronic granulomatous inflammation was noted, more evident in GrHA. In the DV, it was observed bone neoformation restricted to the bone edges and formation of connective tissue with reduced thickness in relation to the bone edges, throughout the defect.Conclusion:The geometry of the biomaterials was determinant in the tissue response, since the microspheres showed more favorable to the bone regeneration in relation to the granules.(AU)
Assuntos
Animais , Ratos , Durapatita/análise , Nanoestruturas , Alginatos/ultraestrutura , Microesferas , Polímeros , Osso e Ossos/cirurgia , Regeneração ÓsseaResumo
RESUMO: As biocerâmicas microporosas de fosfatos de cálcio e bifásicas de hidroxiapatita e fosfato tricálcico beta (HA/TCP-β) na forma de biomateriais granulados microporosos, são temas de pesquisas e se destacam como substitutos ósseos em aplicações biomédicas. As biocerâmicas bifásicas são biocompatíveis, bioativas, osteoindutoras e promovem a osteointegração, quando aplicados in vivo ou em meio simulado. Outro ponto diferencial dessas biocerâmicas está associado à capacidade de solubilidade que esses biomateriais apresentam quando aplicados em meio biológico, permitindo a liberação gradual de íons cálcio e fosfatos para o meio biológico, estes são absorvíeis e promovem a neoformação de um novo tecido ósseo. As biocerâmicas bifásicas de fosfatos de cálcio também se apresentam promissores em aplicações traumatológicas na reparação do tecido ósseo traumatizado e na liberação controlada de medicamentos, em tratamentos da estrutura óssea. O desempenho desses biomateriais como substitutos ósseos e na liberação controlada de medicamentos, estão associados, as suas características físicas, químicas, morfológicas e de superfície. O objetivo desse estudo foi realizar a caracterização morfológica, microestrutural dos biomateriais pela técnica de microscopia eletrônica de varredura (MEV), física com difratometria de raios X (DRX) e método de Arthur para determinação da porosidade aberta. A densidade teórica dos biomateriais bifásicos foi determinada pelo método teórico das concentrações bifásicas. Por fim, se realizou avaliação do comportamento da neoformação óssea e osteointegração dos diferentes biomateriais de fosfatos de cálcio em testes in vivo em ovinos. Os testes in vivo foram realizados em tíbias de ovinos com tempo de implantação de 03 meses. Os biomateriais implantados foram hidroxiapatita (HA), fosfato tricálcico-β (TCP-β) e composições bifásicas HA/TCP-β nas proporções: 80/20, 20/80, 70/30 e 30/70. Foram utilizadas 08 ovelhas mestiças Texel, com 12 meses de idade e peso médio de 30 kg (±5 kg), nas quais foram produzidos três defeitos ósseos em cada tíbia, sendo que quatro desses defeitos foram preenchidos por biomateriais, e dois por fragmentos ósseos (autoenxerto), grupo controle. Os animais foram eutanasiados aos 03 meses após a implantação dos biomateriais. Após a eutanásia, foram coletadas as tíbias para avaliação com o uso da técnica de microscopia eletrônica de varredura (MEV). Os resultados encontrados mostram que os biomateriais granulados microporosos são formados por uma morfologia irregular com tamanho de grânulos entre 200 μm e 500μm, outra constatação foi microestrutura microporosa interconectada dos biomateriais. O resultado obtido da porosidade aberta mostrou que os biomateriais apresentam porosidade superior a 68%. A densidade teórica se apresentou semelhante entre os biomateriais granulados de fosfatos de cálcio e sugerem boa capacidade de neoformação óssea para todos os biomateriais, sendo que o bifásico 20/80 apresentou absorção do biomaterial e neoformação óssea mais rápida quando comparada com os outros biomateriais avaliados neste estudo.
ABSTRACT: Microporous bioceramics of calcium phosphate and biphasic hydroxyapatite and tricalcium phosphate beta (HA/TCP- β) in the form of microporous granules biomaterials are research subjects and stand out as bone substitutes in biomedical application. The biphasic bioceramics are biocompatible, bioactive, osteoinductive and promote osseointegration when applied in vivo or through simulated. Another aspect of such differential solubility bioceramics is associated with the capacity that these biomaterials exhibit when applied in biological environment, enabling the gradual release of calcium and phosphate ions to the biological environment they are absorbable and promote neogenesis of new bone tissue. The biphasic bioceramics of calcium phosphate also have promising applications in traumatology in the repair of injured bone and controlled release of drugs in the bone structure treatments. The performance of these biomaterials as bone substitutes and controlled release of drugs, are associated, their physical, chemical, morphological and surface. The aim of this study was to make morphological, microstructural of biomaterials by the technique of scanning electron microscopy (SEM), physics with X-ray diffraction (XRD) and Arthur method for determination of open porosity. The theoretical density of biphasic biomaterials was determined by theoretical method of biphasic concentrations. Finally, we conducted evaluation of osteogenesis and osseointegration behavior of different biomaterials of calcium phosphates in vivo tests on sheep. In vivo tests were performed on tibias of sheep up to of 03 months. The biomaterials implanted were hydroxyapatite (HA), tricalcium phosphate-β (β-TCP) and biphasic compositions as HA/TCP-β in rates: 80/20, 20/80, 70/30 and 30/70. Eight crossbred Texel sheep, with 12 months of age and average weight of 30 kg (±5 kg) were used, in which were produced three bone defects in the tibia, four of these defects were filled with biomaterials, and two by bone fragments (autograft), as control group. The animals were euthanized at 03 months after implantation of biomaterials. After euthanasia, the tibias were collected for evaluation using the scanning electron microscopy technique (SEM). The results show that the microporous biomaterial granules are formed by an irregular morphology with grain size between 200 μm and 500μm, another finding was microporous interconnected microstructure of biomaterials. The result showed that the open porosity of the biomaterials exhibit porosity greater than 68%. The theoretical density was relatively similar between the granulates biomaterials of calcium phosphates and suggest good capacity of osteogenesis for all biomaterials, with the biphasic absorption of the biomaterial introduced 20/80 and more rapid bone formation when compared with other biomaterials evaluated in study.
Assuntos
Animais , Fosfatos de Cálcio/análise , Ovinos/metabolismo , Durapatita/análiseResumo
As biocerâmicas microporosas de fosfatos de cálcio e bifásicas de hidroxiapatita e fosfato tricálcico beta (HA/TCP-β) na forma de biomateriais granulados microporosos, são temas de pesquisas e se destacam como substitutos ósseos em aplicações biomédicas. As biocerâmicas bifásicas são biocompatíveis, bioativas, osteoindutoras e promovem a osteointegração, quando aplicados in vivo ou em meio simulado. Outro ponto diferencial dessas biocerâmicas está associado à capacidade de solubilidade que esses biomateriais apresentam quando aplicados em meio biológico, permitindo a liberação gradual de íons cálcio e fosfatos para o meio biológico, estes são absorvíeis e promovem a neoformação de um novo tecido ósseo. As biocerâmicas bifásicas de fosfatos de cálcio também se apresentam promissores em aplicações traumatológicas na reparação do tecido ósseo traumatizado e na liberação controlada de medicamentos, em tratamentos da estrutura óssea. O desempenho desses biomateriais como substitutos ósseos e na liberação controlada de medicamentos, estão associados, as suas características físicas, químicas, morfológicas e de superfície. O objetivo desse estudo foi realizar a caracterização morfológica, microestrutural dos biomateriais pela técnica de microscopia eletrônica de varredura (MEV), física com difratometria de raios X (DRX) e método de Arthur para determinação da porosidade aberta. A densidade teórica dos biomateriais bifásicos foi determinada pelo método teórico das concentrações bifásicas. Por fim, se realizou avaliação do comportamento da neoformação óssea e osteointegração dos diferentes biomateriais de fosfatos de cálcio em testes in vivo em ovinos. Os testes in vivo foram realizados em tíbias de ovinos com tempo de implantação de 03 meses. Os biomateriais implantados foram hidroxiapatita...(AU)
Microporous bioceramics of calcium phosphate and biphasic hydroxyapatite and tricalcium phosphate beta (HA/TCP- β) in the form of microporous granules biomaterials are research subjects and stand out as bone substitutes in biomedical application. The biphasic bioceramics are biocompatible, bioactive, osteoinductive and promote osseointegration when applied in vivo or through simulated. Another aspect of such differential solubility bioceramics is associated with the capacity that these biomaterials exhibit when applied in biological environment, enabling the gradual release of calcium and phosphate ions to the biological environment they are absorbable and promote neogenesis of new bone tissue. The biphasic bioceramics of calcium phosphate also have promising applications in traumatology in the repair of injured bone and controlled release of drugs in the bone structure treatments. The performance of these biomaterials as bone substitutes and controlled release of drugs, are associated, their physical, chemical, morphological and surface. The aim of this study was to make morphological, microstructural of biomaterials by the technique of scanning electron microscopy (SEM), physics with X-ray diffraction (XRD) and Arthur method for determination of open porosity. The theoretical density of biphasic biomaterials was determined by theoretical method of biphasic concentrations. Finally, we conducted evaluation of osteogenesis and osseointegration behavior of different biomaterials of calcium phosphates in vivo tests on sheep. In vivo tests were performed on tibias of sheep up to of 03 months. The biomaterials implanted were hydroxyapatite (HA), tricalcium phosphate-β (β-TCP) and biphasic compositions as HA/TCP-β in rates: 80/20, 20/80, 70/30 and 30/70. Eight crossbred Texel sheep, with 12 months of age and average weight of 30 kg (±5 kg) were used...(AU)
Assuntos
Animais , Fosfatos de Cálcio/análise , Ovinos/metabolismo , Durapatita/análiseResumo
Purpose: To evaluate the polymer doped rods behavior with bioactive glass and hydroxyapatite for possible application as a fracture fixing method. Methods Twenty eight Rattus norvegicus Wistar underwent bone defect for access to the femoral medullary canal and distributed into three experimental groups: group A - doped castor bean polymer with bioactive glass; group B - castor bean polymer and; group C - castor bean polymer doped with bioactive glass and hydroxyapatite. After 15 and 60 evaluation days, the femurs were removed and sent for histology and scanning electron microscopy. Results Initially mild and moderate inflammatory infiltrate is observed that decreases as time goes by, and the presence of connective tissue capsule around the graft in all groups. Regarding the biomaterials resorption little was observed. The implanted rods did not favor the osteoconductive process in the femoral medullary canal which was observed only in the C15 group. Conclusions The association of castor bean polymer, bioactive glass and hydroxyapatite was biocompatible and osteointegrable. The osteoconductive only occurred in the presence of hydroxyapatite and bioactive glass (C15 Group) and little biodegradation was observed.(AU)
Assuntos
Animais , Ratos , Ricinus communis , Poliuretanos/uso terapêutico , Durapatita/uso terapêutico , Materiais Biocompatíveis/uso terapêutico , Fixação Intramedular de Fraturas , Ratos Wistar , Fraturas Ósseas/terapiaResumo
The study aimed to evaluate biocompatibility, osteoconduction and osseointegration of a pasty composite of hydroxyapatite (20%) and lignin (80%) as a promoter of metal implant and bone tissue integration. An intramedullary Schanz pin was implanted in both tibias of fifteen bitches. In the left tibia, the pin was coated with the biomaterial at the time of surgery. Marrow cavity was also filled with the biomaterial. Right limb did not receive the biomaterial, then constituting the control group. Tibias were harvested from five animals at 8, 60 and 150 days after surgery; three of them were analyzed by histological and biomechanical assessment and the two remaining tibias by X-ray diffraction. Results showed that the biomaterial is biocompatible, with osteoconductivity and osseointegration properties. Histological analysis and diffractograms showed the presence of hydroxyapatite in samples in all periods, although the presence of organic material of low crystallinity was variable. There was no statistical difference in the forces required for removal of the biocompatibility, osteoconductivity and osseointegration, it was not able to promote a better intramedullary pin anchorage.(AU)
O trabalho objetivou avaliar a biocompatibilidade, a osteocondução e a osseointegração de um compósito pastoso de hidroxiapatita (20%) e lignina (80%) como promotor de integração entre implante metálico e tecido ósseo. Um pino intramedular de Schanz foi implantado em ambas as tíbias de quinze cadelas. Na tíbia esquerda, o pino foi coberto com o biomaterial no momento da cirurgia. A cavidade medular também foi preenchida com o biomaterial. O membro direito não recebeu o biomaterial, constituindo assim o grupo controle. As tíbias foram coletadas de cinco animais aos oito, 60 e 150 dias após a cirurgia, sendo três encaminhadas para avaliação histológica e biomecânica e as duas restantes, para difração de raios X. Os resultados revelaram biocompatibilidade do material, com propriedades de osteocondução e osseointegração. As análises histológicas e os difratogramas mostraram presença da hidroxiapatita no tecido em todos os períodos avaliados, embora a presença de material orgânico de baixa cristalinidade tenha sido variável. Não houve diferença estatística na força necessária para remoção do pino intramedular entre os tempos ou tratamentos. Embora o biomaterial tenha apresentado biocompatibilidade, osteocondutividade e osseointegração, ele não foi capaz de promover uma melhor ancoragem do pino intramedular.(AU)
Assuntos
Animais , Cães , Durapatita , Durapatita/síntese química , Lignina , Osso e Ossos , CãesResumo
The present study aims to assess the effects of cigarette smoke inhalation and/or coffee consumption on bone formation and osseous integration of a dense hydroxyapatite (DHA) implant in rats. For this study, 20 male rats were divided into four groups (n = 5): CT (control) group, CE (coffee) group, CI (cigarette) group and CC (coffee + cigarette) group. During 16 weeks, animals in the CI group were exposed to cigarette smoke inhalation equivalent to 6 cigarettes per day; specimens in the CE group drank coffee as liquid diet; and rats in the CC group were submitted to both substances. In the 6th week a 5 mm slit in the parietal bone and a 4 mm slit in the tibia were performed on the left side: the former was left open while the latter received a DHA implant. As soon as surgeries were finished, the animals returned to their original protocols and after 10 weeks of exposure they were euthanised (ethically sacrificed) and the mentioned bones collected for histological processing. Data showed that exposure to cigarette smoke inhalation and coffee consumption did not interfere in weight gain and that solid and liquid diet consumption was satisfactory. Rats in the CC group showed a decrease in bone neoformation around the tibial DHA implant (31.8 ± 2.8) as well as in bone formation in the parietal slit (28.6 ± 2.2). On their own, cigarette smoke inhalation or coffee consumption also led to diminished bone neoformation around the implant and delayed the bone repair process in relation to the CT group. However, reduction in the bone repair process was accentuated with exposure to both cigarette smoke inhalation and coffee consumption in this study.(AU)
O presente estudo teve como objetivo avaliar os efeitos do tabagismo e do consumo de café, isolada ou concomitantemente, sobre a formação óssea e a osseointegração de implantes hidroxiapatita densa. Foram utilizados 20 ratos machos, divididos em quatro grupos (n = 5): grupo CT (controle); grupo CA (café); grupo CI (cigarro), e grupo CC (cigarro + café). Durante 16 semanas, os animais do grupo CI foram expostos à fumaça de seis cigarros/dia; os animais do grupo CA consumiram café como dieta líquida, e os animais do grupo CC, ambas as substâncias. Após seis semanas de exposição, uma falha óssea de 5 mm foi produzida no osso parietal esquerdo e de 4 mm, na tíbia esquerda dos animais. A falha do parietal foi mantida aberta, enquanto na tíbia corpos cerâmicos de hidroxiapatita densa (HAD) foram implantados em cavidade produzida cirurgicamente. Após as cirurgias, os animais retornaram aos protocolos experimentais e, ao término de dez semanas, foram eutanasiados, sendo as tíbias e os parietais coletados para processamento histológico. A exposição à fumaça do cigarro e o consumo de café não interferiram no ganho de peso dos animais, e os consumos de dieta líquida e sólida foram satisfatórios entre os grupos. Os animais do grupo CC apresentaram menor volume de osso neoformado ao redor do implante de HAD na tíbia (31,8 ± 2,8) e menor osteogênese na falha produzida no osso parietal (28,6 ± 2,2). O café e o cigarro consumidos isoladamente provocam a diminuição do volume de osso ao redor do implante e o atraso no processo de reparação óssea. Observou-se que o consumo de café associado à exposição à fumaça do cigarro reduziu de forma acentuada o processo de reparação óssea, no presente estudo.(AU)
Assuntos
Animais , Ratos , Próteses e Implantes/efeitos adversos , Cafeína/efeitos adversos , Nicotina/efeitos adversos , Osteogênese , Durapatita , Osso e Ossos , Materiais BiocompatíveisResumo
PURPOSE: Articular Cartilage has limited potential for self-repair and tissue engineering approaches attempt to repair articular cartilage by scaffolds. We hypothesized that the combined hydroxyapatite and zirconia stabilized yttria would enhance the quality of cartilage healing. METHODS: In ten New Zealand white rabbits bilateral full-thickness osteochondral defect, 4 mm in diameter and 3 mm depth, was created on the articular cartilage of the patellar groove of the distal femur. In group I the scaffold was implanted into the right stifle and the same defect was created in the left stifle without any transplant (group II). Specimens were harvested at 12 weeks after implantation, examined histologically for morphologic features, and stained immunohistochemically for type-II collagen. RESULTS: In group I the defect was filled with a white translucent cartilage tissue In contrast, the defects in the group II remained almost empty. In the group I, the defects were mostly filled with hyaline-like cartilage evidenced but defects in group II were filled with fibrous tissue with surface irregularities. Positive immunohistochemical staining of type-II collagen was observed in group I and it was absent in the control group. CONCLUSION: The hydroxyapatite/yttria stabilized zirconia scaffold would be an effective scaffold for cartilage tissue engineering.(AU)
Assuntos
Animais , Coelhos , Cartilagem Articular/anatomia & histologia , Durapatita/análise , Colágeno/análise , Coelhos/classificaçãoResumo
A fim de avaliar a resposta biológica da hidroxiapatita sintética (HAP-91) nos alvéolos de felinos domésticos, este biomaterial foi implantado após extração do terceiro pré-molar inferior direito em 12 gatos e mantida por meio de uma membrana de celulose bacteriana. No lado esquerdo, os alvéolos foram apenas recobertos com a membrana de celulose bacteriana, formando o grupo-controle. Observou-se, durante a avaliação clínica, que todos os animais voltaram a comer normalmente ração úmida, sem apresentarem sinais de dor ou desconforto após a recuperação anestésica. A cicatrização da ferida cirúrgica ocorreu de forma satisfatória, sendo que a membrana de celulose bacteriana evitou a saída precoce da hidroxiapatita. Radiograficamente, aos 50 dias, todos os animais apresentaram radiopacidade óssea homogênea em ambos os lados. À análise histomorfométrica, observou-se adiantamento do processo de reparo do osso alveolar nos oito primeiros dias do grupo-tratado quando comparado ao grupo-controle, bem como atraso aos 30 dias, porém, aos 50 dias, ambos os grupos apresentavam porcentagem de tecido ósseo semelhante e morfologicamente normal. Os resultados sugerem que a hidroxiapatita é biocompatível, integra-se ao tecido ósseo alveolar e pode ser utilizada em felinos.(AU)
The biocompatibility of a material depends on its characteristics, as well as the species and the environment recipient. In order to evaluate the biological response of the synthetic hydroxyapatite (HAP-91) in feline dental alveoli, it was implanted in the right inferior third premolar after extraction in 12 cats and maintained through a bacterial cellulose membrane. On the left side the alveoli was covered with a bacterial cellulose membrane (control group). During clinical evaluations it was observed that the animals started to eat after the anesthetic recovery time, without clinical signs of pain. There was a satisfactory cicatrization of the surgical wound and the bacterial cellulose membrane aided in repairing the gum, avoiding the loss of the hydroxyapatite. Radiographs taken 50 days post surgery presented homogeneous bone radiopacity on both sides. The histological and histomorfometrical analysis showed a positive progress of the alveolar repair in the first 8 days in the treated group when compared to the control group and a delay at 30 days, however at 50 days both presented a similar and morphologically normal percentage of bone tissue. These findings suggest that HAP-91 is biocompatible and integrates into the feline alveolar bone.(AU)
Assuntos
Animais , Gatos , Gatos/metabolismo , Gatos/microbiologia , Durapatita/análise , Durapatita , Alvéolo Dental , Celulose/análiseResumo
Alcohol consumption compromises bone tissue, and thus may either impair or stop the fixation and maintenance of osseointegrated implants. To evaluate the effects of 5 percent and 15 percent ethanol on bone neoformation around porous hydroxiapatite implants. Fifteen rats were separated into 3 groups of 5 animals each: control (CT); 5 percent alcohol (A); and 15 percent alcohol (AA). After four weeks of ethanol consumption, the rats received porous hydroxiapatite implants into surgically made cavities in the femur. After surgery, the animals continued to consume ethanol until day 90 of the experiment, when they were euthanised and their femurs removed for histological processing. Bone tissue was found around the ceramic specimens of all the animals. The largest volume of neoformed bone around ceramic specimens occurred in the CT group, and the smallest in the AA group, followed by the A group. It was concluded that ethanol consumption produced a negative effect on osteogenesis around hydroxyapatite implants. Even small doses, such as the 5 percent ethanol dilution can interfere with bone repair.
O consumo de álcool é prejudicial à integridade do tecido ósseo; consequentemente, pode dificultar ou até mesmo impedir a fixação e manutenção dos implantes osseointegráveis. Avaliar os efeitos do etanol (5 por cento e 15 por cento) sobre a neoformação óssea ao redor de implantes de hidroxiapatita porosa. Foram utilizados 15 ratos divididos em três grupos de 5: controle (CT); álcool 5 por cento (A); e álcool 15 por cento (AA). Após quatro semanas de consumo de etanol, a hidroxiapatita porosa foi implantada em cavidades produzidas cirurgicamente nos fêmures dos animais. Após as cirurgias, os animais continuaram a consumir etanol até completar 90 dias de experimento, quando foram sacrificados e os fêmures isolados para o processamento histológico. Em todos os animais foi encontrado tecido ósseo junto aos corpos cerâmicos. O volume de osso formado ao redor dos corpos cerâmicos foi maior no grupo CT em relação aos demais grupos. Os animais do grupo AA foram aqueles que apresentaram menor volume de osso neoformado, seguidos dos animais do grupo A. Conclui-se que o consumo de etanol produziu efeito negativo sobre a osteogênese ao redor dos implantes de HAP, e que mesmo doses pequenas, como a diluição de etanol 5 por cento, podem interferir na reparação óssea.
Assuntos
Animais , Masculino , Ratos , Substitutos Ósseos , Durapatita , Etanol/farmacologia , Fêmur/cirurgia , Osseointegração/efeitos dos fármacos , Osteogênese/efeitos dos fármacos , Fêmur/patologia , Porosidade , Próteses e Implantes , Ratos WistarResumo
Avaliou-se mecanicamente o compósito de poli-hidroxibutirato 70 por cento e hidroxiapatita 30 por cento na forma de placas para fixação óssea. Foram utilizadas 15 placas do compósito com 60mm de comprimento por 10mm de largura e espessura variando de 3mm no centro a 5mm nas extremidades, com seis orifícios. As placas foram fixadas em um modelo acrílico de fêmur de gato, e o conjunto foi submetido aos testes de flexão com quatro pontos, compressão axial e torção, empregando-se como referência microplacas de aço ASTM-F138 2,0mm. As médias das forças máximas nos testes de flexão e de compressão foram, respectivamente, de 323,20N e 617,70N, para as placas de compósito, e de 352,33N e 547,70N, para as placa de aço. No teste de torção, as médias dos torques máximos foram de 1,01Nm para as placas de compósito e de 1,15Nm para as placas de aço. Não houve diferença estatística entre as placas de compósito e de aço. O comportamento físico do material foi diferente, pois as placas de compósito se romperam e as de aço apenas se deformaram, revelando baixa ductilidade das placas de compósito.(AU)
Fixation bone plates made of 70 percent polyhydroxybutyrate and 30 percent hydroxyapatite composite were mechanically evaluated. The fifteen composite plates employed presented six holes and measured 60 x 10mm, length and width, respectively, with thickness ranging from 3 to 5mm according to the region. The plates were fixed in acrylic models of cat femur, then were subjected to tests of four-points bending, axial compression, and torsion, using as reference 2mm stainless steel plates. The means of the maximum force in flexion and compression tests were, respectively, 323.20N and 617,70N for the composite plates and 352.33N and 547.70N for the steel plates. In the torsional test, the means of torque were 1.01Nm for the composite plates and 1.15Nm for steel plates. There were no statistical differences between the plates of composite and steel. The physical behavior of the material was different once the composite plates broke up while the stainless steel ones only presented deformation, revealing the low ductility of the composite plates.(AU)
Assuntos
Gatos , Gatos/classificação , Durapatita/análise , Osso e Ossos/anatomia & histologiaResumo
Avaliou-se o compósito de poli-hidroxibutirado (PHB) 70 por cento e hidroxiapatita (HA) 30 por cento na forma de placas para fixação óssea em gatos. Foram usadas placas do compósito com 60mm de comprimento por 10mm de largura e espessura variando de 3mm no centro a 5mm nas extremidades, com seis orifícios. A placa do compósito foi empregada na fixação de osteotomia de fêmur em quatro gatos, totalizando seis intervenções. Verificou-se a ruptura de cinco placas (83,3 por cento) até o quarto dia e de uma placa (16,7 por cento) aos 21 dias, quando se observou um calo ósseo exuberante. O resultado da implantação da placa no gato mostrou que o compósito não possui resistência suficiente para ser empregado como placas de fixação de fêmur em gatos.(AU)
The composite of polyhydroxybutyrate (PHB) 70 percent and hydroxyapatite (HA) 30 percent was evaluated as plate for bone fixation in cats. The employed composite plates presented six orifices and measured 60 x 10mm, length and width, respectively, with thickness ranging from 3 to 5mm according to the region. The composite plate was used in the fixation of femoral osteotomy in four cats, in a total of six interventions. There were ruptures in five plates (83.3 percent) until day 4 and in one plate (16.7 percent) on the day 21, when it was possible to observe an exuberant osseous callus. The result of the plate deployment in the cat showed that the composite does not have sufficient strength to be used as plate of femoral fixation in cats.(AU)
Assuntos
Animais , Gatos , Materiais Biocompatíveis/uso terapêutico , Fixação de Fratura/veterinária , Hidroxibutiratos , Durapatita , GatosResumo
Avaliou-se a hidroxiapatita com alandronato e hidroxiapatita com colágeno na aceleração da consolidação óssea do rádio de cadelas adultas submetidas à ovariossalpingo-histerectomia (OSH). Utilizaram-se 14 cadelas adultas, distribuídas aleatoriamente em dois grupos: grupo-controle e grupo OSH (submetidas à OSH). Quatro meses após a OSH, as cadelas dos dois grupos foram submetidas à cirurgia para produção de uma falha óssea de 4mm de diâmetro nos terços distal e proximal do rádio. No terço distal do membro direito, foi utilizada a hidroxiapatita com alandronato e, no membro esquerdo, a hidroxiapatita com colágeno; no terço proximal, não se utilizou nenhum biomaterial. Houve retardo na consolidação das falhas ósseas nas cadelas submetidas à OSH comparadas com as não submetidas. A hidroxiapatita com alandronato acelerou o processo de reparação e, em todos os animais dos dois grupos, a densidade óssea foi significativamente maior no terço distal onde foi implantada. Os dois biomateriais apresentaram biocompatibilidade, constatada pela ausência de reação inflamatória ou outra reação indesejável.(AU)
The hydroxyapatite with alendronate and hydroxyapatite with collagen were evaluated in the acceleration of the bony consolidation of adult spayed bitch radius. For that, 14 adult bitches were distributed in two groups (control and spayed). Four months after ovariohysterectomy, the groups were submitted to the surgery for production of a 4mm diameter bony flaw in the distal and proximal third regions of the radius. In the distal region of the right thoracic limb, hydroxyapatite with alendronate was used. In the distal region of the left thoracic limb, hydroxyapatite with collagen was used. Any biomaterial was used in proximal part of the limb. There was a retard in bony flaws consolidation in the spayed bitches. Hydroxyapatite with alendronate showed better result, since the place it was implanted considerably increased the bony formation. Both biomaterials presented biocompatibility, verified by the absence of inflammatory reaction or other undesirable reaction.(AU)
Assuntos
Animais , Cães , Durapatita/análise , Alendronato/análise , Colágeno/análise , Rádio (Anatomia)/cirurgia , Tubas Uterinas/cirurgia , Histerectomia/métodos , Ovariectomia/métodos , Calo ÓsseoResumo
Para avaliar o compósito hidroxiapatita-lignina na osseointegração entre implante metálico e o tecido ósseo, foram utilizados 20 coelhos adultos, nos quais foi realizada uma falha óssea na face lateral proximal de ambas as tíbias. Na tíbia esquerda, introduziu-se, no canal medular, um pino intramedular de Schanz revestido com o compósito em sua parte rosqueada, após o preenchimento daquele com 1000mg do compósito. A falha cortical foi preenchida com o compósito. O mesmo foi feito na tíbia direita, porém sem a utilização do compósito, servindo como controle. A avaliação clínica baseou-se na deiscência, claudicação, sensibilidade dolorosa e circunferência tibial. Foram realizadas radiografias imediatamente após a cirurgia e aos oito, 30, 60, 90 e 120 dias do pós-operatório. A maioria dos animais apresentou evolução clínica normal. Nas radiografias do grupo tratado, houve decréscimo da radiopacidade no defeito e no espaço medular até tornar-se semelhante à do osso circunvizinho, quadro inverso ao do grupo-controle. Conclui-se que o compósito hidroxiapatita-lignina não mostrou indícios clínicos de rejeição e que o tecido visualizado na altura da falha óssea e ao redor do pino intramedular tinha radiopacidade semelhante à do osso circunvizinho, o que sugere que o material promoveu a integração com o tecido ósseo.(AU)
This study evaluated a sinthetic hydroxyapatite-lignin composite for osseoingration between metallic implant and bone tissue. Twenty New Zealand rabbits were used. A defect was made a the proximal region of lateral surfaces of both tibias. An intramedullary pin was inserted in the medullary cavity of the left tibia after filling the cavity with 1,000mg of the composite and covering the thread part of the pin with the composite. The same procedure was made in control tibias without the composite. Clinical evaluation was based on inflammatory reaction, dehiscence, lameness, pain, and tibial circumference. Radiographs were made immediately after surgery and then on days eight, 30, 60, 90, and 120. Most of the animals presented normal clinical progression. Radiographies of treated group showed decrease in the defect and medullary cavity radiopacity to the same pattern of the surrounding bone, while the contrary happened in control group; but, in this group, the medullary cavity remained radioluscent at the last observation date. It can be concluded that the hydroxyapatite-lignin composite did not show clinical signs of rejection and that radiopacity of the tissue in the bone defect and surrounding the pin was similar to bone radiopacity, suggesting that the material promoted osseointegration.(AU)
Assuntos
Animais , Masculino , Osseointegração , Durapatita/análise , Durapatita , Lignina , Próteses e Implantes/veterinária , Osso e Ossos , Osso e Ossos/cirurgia , Pinos Ortopédicos , CoelhosResumo
Avaliaram-se a biocompatibilidade, a osseointegração, a osseocondução e a biodegradação de compósitos de 50 por cento hidroxiapatita (HAP-91®) e 50 por cento poli-hidroxibutirato. O compósito foi implantado em defeitos ósseos em 12 coelhos (grupo experimental), sendo comparado a defeitos não preenchidos (grupo-controle, de igual número). Os parâmetros clínicos dor, claudicação, infecção, deiscência e edema foram avaliados nos primeiros oito dias após a cirurgia e aos 45 e 90 dias. Radiografias foram realizadas aos oito, 45 e 90 dias após a cirurgia em quatro animais por grupo que, em seguida, foram submetidos à eutanásia para coleta de amostras destinadas a análises histológica e histomorfométrica. Não ocorreram diferenças entre os grupos para todos os parâmetros clínicos. Radiografias demonstraram um compósito com radiopacidade semelhante à do osso vizinho e contato direto entre osso e compósito aos 45 e 90 dias. Diferença significativa foi observada entre a porcentagem dos tecidos ósseo e conjuntivo dentro do defeito nos dias oito, 45 e 90, assim como na interface aos 45 e 90 dias. Foram observadas projeções dos tecidos ósseo e conjuntivo no interior do compósito e sinais de biodegradação na ausência de infiltrado inflamatório. Pode-se concluir que o compósito é biocompatível, osseocondutor, biodegradável e se integra ao tecido ósseo.(AU)
The biocompatibility, osseointegration, osseoconductivity, and biodegradation of a 50-50 percent hydroxyapatite (HAP-91®)-polyhydroxybutyrate were evaluated. The composite was implanted in bone defects of 12 rabbits (experimental group), being compared to unfilled defects (control group, 12 animals). The clinical parameters of pain, lameness, infection, dehiscence, and edema were evaluated during the first eight days and on the 45th and 90th days after surgery. Radiographs were taken in four animals per group at 8, 45, and 90 days after surgery, when animals were euthanized to collect samples for histology and histomorphometry. Significant differences between groups for all clinical parameters were not observed. Radiographs showed a similar radiopacity of the composite and bone and their direct contact. More bone than connective tissue was found within the defect at 8, 45, and 90 days and at the interface on the 45th and 90th days. Projections of bone and connective tissue were seen inside the composite. Biodegradation signs became evident, with absence of inflammatory infiltrate. Data support that such composite is biocompatible, osseoconductive, biodegradable, and integrate to bone.(AU)
Assuntos
Animais , Masculino , Adulto , Resinas Compostas , Durapatita/administração & dosagem , Hidroxibutiratos/administração & dosagem , Osso e Ossos/anormalidades , Substitutos Ósseos , Condução Óssea , Implantes Absorvíveis , CoelhosResumo
Avaliou-se o efeito da hidroxiapatita sintética na regeneração do osso alveolar e o efeito no tecido vivo de cães. Em dois grupos de 14 cães adultos hígidos, pesando entre 10 e 15kg, foram criados defeitos de 6 x 5mm na superfície vestibular do processo alveolar mandibular direito até atingir a raiz do quarto pré-molar. Em um grupo (tratado), o defeito foi preenchido com hidroxiapatita sintética; o grupo sem tratamento foi usado como controle. Efetuaram-se avaliações clínicas diárias durante uma semana, avaliações radiográficas após a cirurgia e aos oito, 21, 42, 60, 90 e 120 dias do pós-operatório. Vinte e quatro cães apresentaram inflamação, sendo a recuperação no grupo tratado mais lenta. Todos os animais tiveram sangramento com a hidroxiapatita. No grupo-controle houve aumento crescente da radiopacidade dos defeitos, no entanto, aos 120 dias do pós-operatório, os defeitos ainda eram visíveis. No grupo tratado, inicialmente a radiopacidade foi maior que a do osso normal, com diminuição gradual até se tornar semelhante à do osso vizinho, 60 dias após a cirurgia. A hidroxiapatita T290800-1 acelerou o preenchimento do defeito provocado no processo alveolar e acarretou inflamação e hemorragia gengival, o que, no entanto, não contra-indicou o seu uso.(AU)
The effect of the synthetic hydroxyapatite on the regeneration of the alveolar bone of dogs and on the alive tissue were evaluated. In two groups of 14 adult healthy dogs, weighing from 10 to 15kg, some defects around 6 x 5mm were provoked on the vestibular surface of the right jaw alveolar process until reaching the root of the forth premolar. In one group, the defect was infilled with synthetic hydroxyapatite. The no treated group dogs were used as control. Clinical evaluations were daily performed over one week, as well as radiographic evaluations after surgery, and on 8, 21, 42, 60, 90 and 120 days after surgery. Twenty-four dogs showed inflammation and the recovery in the treated group was slower than in the control group. Bleeding at the presence of hydroxyapatite was observed in all the animals. The radiographic examination presented an increasing radiopacity in the control group; however, this defect was still visible on day 120 after operation. Initially, in the treated group, radiopacity was higher than that of the normal bone and a gradual decrease occurred until becoming similar to the adjacent bone on day 60 days after surgery. The hydroxyapatite T290800-1 accelerated the infilling of the defect provoked in the alveolar process and caused gingival inflammation and hemorrhage; however, this does not contraindicate its use.(AU)
Assuntos
Animais , Durapatita/efeitos adversos , Processo Alveolar/transplante , Transplante Autólogo/métodos , Transplante Autólogo/efeitos adversos , Implante de Prótese Mandibular/métodos , Implante de Prótese Mandibular/efeitos adversos , Cães , Regeneração Óssea , Radiografia Dentária/métodosResumo
Twenty-five arthrodeses were performed in four cats and 17 dogs using synthetic hydroxyapatite as fresh autogenous graft cancellous bone substitute. Arthrodesis was performed in the carpal joint in eight cases, in the tarsal joint in 10, in the elbow joint in six, and in the knee joint in one case. The mean radiographic follow-up time was 30 days in one animal, 45 days in another animal and 60 days in the 19 remaining cases. Bone union was observed in 24 arthrodeses. Non-union of one elbow arthrodesis was due to failure of stabilization. Restoration of limb functionality was classified as good to excellent in 22 cases. Hydroxyapatite was able to promote bone growth and is suitable for using in routine surgical procedures for small animals(AU)
Realizaram-se 25 artrodeses em 21 casos, quatro em gatos e 17 em cães, utilizando hidroxiapatita sintética como substituto ao enxerto ósseo autógeno esponjoso fresco, sendo oito na articulação do carpo, 10 na articulação do tarso, seis na do cotovelo e uma na do joelho. As avaliações radiográficas foram realizadas aos 30 dias em um animal, aos 45 dias em outro e aos 60 dias nos 19 casos restantes. Visibilizou-se união óssea em 24 artrodeses e a não-união em um cotovelo foi atribuída a falha na estabilização. O retorno à função do membro foi classificado de bom a excelente em 22 casos. A hidroxiapatita foi capaz de viabilizar o crescimento ósseo e mostrou-se factível para utilização na prática cirúrgica rotineira em pequenos animais(AU)