Influencia do peso na hemodinâmica testicular em cães avaliados através da ultrassonografia Doppler / Influence of weight on testicular hemodynamics in dogs evaluated by Doppler ultrasound
R. bras. Reprod. Anim.
; 44(4): 129-134, out.-dez. 2020. ilus, tab
Article
em Pt
| VETINDEX
| ID: vti-763421
Biblioteca responsável:
BR68.1
Localização: BR68.1
RESUMO
A ultrassonografia com ferramenta Doppler é o melhor método de avaliação da vascularização testicular. Objetivou-se comparar a influência do peso dos animais e do lado testicular em relação à hemodinâmica da artéria testicular de cães. Foram utilizados 17 cães machos sadios, com idades entre 8 e 48 meses. Os animais foram pesados e divididos em dois grupos 1) 0-20 kg e 2) >20 kg, colocados em decúbito dorsal e a artéria testicular foi localizada na região de cordão espermático, com a ferramenta Doppler colorido e pulsado. Os parâmetros de velocidade do fluxo sanguíneo e os índices hemodinâmicos foram determinados em avaliação única. Utilizou-se o Modelo misto do SAS para determinar os efeitos de peso (> ou < 20kg) e lado (direito e esquerdo) das variáveis (VPS, VFD, TAMEAN, TAMAX, RI, PI, S/D, DA). A onda encontrada nessa região foi de padrão de baixa resistividade. Não foram identificados efeitos de lado nas variáveis avaliadas. O diâmetro da artéria testicular foi maior (AU)
ABSTRACT
Doppler ultrasonography is the best method to evaluate testicular vascularization. The objective of this study was to compare the influence of animal weight and testicular side on the hemodynamics of testicular artery in dogs. Seventeen healthy male dogs, aged between 8 and 48 months, were used. The animals were weighed and divided into 1) 0-20 kg and 2)> 20 kg., Placed in dorsal decubitus position and the testicular artery was located in the region of the spermatic cord, using the pulsed and colored Doppler tool. The parameters of blood flow velocity and hemodynamic indices were determined in a single evaluation. The mixed SAS model was used to determine the effects of weight (> or < 20Kg) and side (right and left) variables (VPS, VFD, TAMEAN, TAMAX, RI, PI, S / D, DA, VFS). The wave found in this region was pattern of low resistance. No side effects were identified in the variables evaluated. Diameter of the testicular artery was higher (p<0.05) (1.86mm) in the group of animals of greater weight. In dogs, testicular diameter may be influenced by animal weight. It should be taken into account at the time of interpretation as this may influence the estimates of arterial diameter.(AU)
Palavras-chave
Texto completo:
1
Base de dados:
VETINDEX
Idioma:
Pt
Revista:
R. bras. Reprod. Anim.
/
Rev. bras. reprod. anim
Ano de publicação:
2020
Tipo de documento:
Article