Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 229
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38629760

RESUMO

OBJECTIVES: This study investigates effects of surgical guide manufacturing process on 3D transfer accuracy of planned dental implant position, using three production methods: additive 3D-printed (3DF), subtractive milled (MF), and analog laboratory fabricated templates (LF). MATERIAL AND METHODS: Implant position for a single-tooth gap (#26) planned digitally. 3DF and MF templates were designed digitally, while LF templates were analogously created. For each manufacturing type, 10 surgical guides were fabricated. Each guide was used for template-guided implant placement in model replicas. For evaluation of implant placement, cone beam computed tomography scans of all implanted models were superimposed, and implant positions were determined. Deviations at implant shoulder/apex were measured, and median and inter-quartile range (IQR) were determined for mesio-distal, oro-facial, coronal apico, 3D spaces, and angles. RESULTS: At implant shoulder, vertical components dominated position deviations (up to 1.04 mm, IQR 0.28 mm for 3DF). Horizontal deviations were much lower (mesio-distally up to 0.38 mm, IQR 0.36 mm (LF)). Implant apex shows similar vertical deviations, while horizontal deviations clearly increased compared to shoulder, especially in mesio-distal direction. Median angular deviations were between 2.1° (IQR 2.0 mm, max. 4.2°) for 3DF and 3.3° (IQR 1.9 mm, max. 5.3°) for MF. No statistical differences were found between manufacturing types (Kruskal-Wallis test, p = .05). CONCLUSIONS: The study showed the method of implant guide fabrication did not affect the accuracy of implant placement within the limits of an in vitro environment. All methods resulted in implant placement which did not exceed the accepted safety deviation envelope (1.5-2.0 mm).

2.
Orthod Craniofac Res ; 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38887908

RESUMO

OBJECTIVES: Investigating the impact of thermal and mechanical loading on the force generation of orthodontic aligners made from various thermoplastic materials and different compositions. MATERIALS AND METHODS: Five distinct materials were utilized including, three multi-layer (Zendura FLX, Zendura VIVA, CA Pro) and two single-layer (Zendura A and Duran). A total of 50 thermoformed aligners (n = 10) underwent a 48-hour ageing protocol, which involved mechanical loading resulting from a 0.2 mm facial malalignment of the upper right central incisor (Tooth 11) and thermal ageing through storage in warm distilled water at 37°C. The force exerted on Tooth 11 of a resin model was measured both before and after ageing using pressure-sensitive films and a biomechanical setup. RESULTS: Before ageing, pressure-sensitive films recorded normal contact forces ranging from 83.1 to 149.7 N, while the biomechanical setup measured resultant forces ranging from 0.1 to 0.5 N, with lingual forces exceeding facial forces. Multi-layer materials exhibited lower force magnitudes compared to single-layer materials. After ageing, a significant reduction in force was observed, with some materials experiencing up to a 50% decrease. Notably, multi-layer materials, especially Zendura VIVA, exhibited lower force decay. CONCLUSIONS: The force generated by aligners is influenced by both the aligner material and the direction of movement. Multi-layer materials exhibit superior performance compared to single-layer materials, primarily because of their lower initial force, which enhances patient comfort, and their capability to maintain consistent force application even after undergoing ageing.

3.
Orthod Craniofac Res ; 2024 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-38459802

RESUMO

OBJECTIVES: To use the finite element method (FEM) to investigate the effect of various attachment configurations and trimming line designs of orthodontic aligners on their biomechanical performance. METHOD: A 3D upper jaw model was imported into 3D design software. The upper right central incisor tooth (Tooth 11) was made mobile, and its periodontal ligament (PDL) and bone structures were designed. Aligners were modelled with three distinct attachment configurations: No attachment, rectangular horizontal, rectangular vertical, and two trimming line designs; scalloped and straight extended, with a homogeneous thickness of 0.6 mm. These models were then imported into an FE software. Simulations were conducted for three different movements, including facial translation, distalization, and extrusion. RESULTS: Forces were recorded at 1.3-2.6 N during facial translation, 1.4-5.9 N in distalization, and 0.0-2.0 N in extrusion. The straight extended trimming line consistently generated higher forces than the scalloped design. Attachments had no significant impact on force components during facial translation but were more effective in distalization and extrusion. The combination of a straight extended trimming line with horizontal attachments exhibited the least stresses at the apical third during distalization, and the highest stresses during extrusion, suggesting superior retention. CONCLUSIONS: Rectangular attachments offer limited benefits in facial translation, but horizontal rectangular attachments can intensify load in distalization and are crucial for force generation in extrusion. Horizontal attachments are preferred over vertical options. Additionally, the straight extended trim line enhances control of tooth movement and can replace attachments in certain cases. CLINICAL RELEVANCE: These findings provide biomechanical evidence and an optimal protocol to guide clinical practice in planning diverse teeth movements. The emphasis is on the influence of attachment utilization and the specific design of aligner trimming lines to enhance control over tooth movement.

4.
Clin Oral Investig ; 28(5): 258, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38637429

RESUMO

OBJECTIVES: To investigate the effects of material type and thickness on force generation and distribution by aligners. MATERIALS AND METHODS: Sixty aligners were divided into six groups (n = 10): one group with a thickness of 0.89 mm using Zendura Viva (Multi-layer), four groups with a thickness of 0.75 mm using Zendura FLX (Multi-layer), CA Pro (Multi-layer), Zendura (Single-layer), and Duran (Single-layer) sheets, and one group with a thickness of 0.50 mm using Duran sheets. Force measurements were conducted using Fuji® pressure-sensitive films. RESULTS: The lowest force values, both active and passive, were recorded for the multi-layered sheets: CA Pro (83.1 N, 50.5 N), Zendura FLX (88.9 N, 60.7 N), and Zendura Viva (92.5 N, 68.5 N). Conversely, the highest values were recorded for the single-layered sheets: Duran (131.9 N, 71.8 N) and Zendura (149.7 N, 89.8 N). The highest force was recorded at the middle third of the aligner, followed by the incisal third, and then the cervical third. The net force between the incisal and cervical thirds (FI-FC) showed insignificant difference across different materials. However, when comparing the incisal and middle thirds, the net force (FI-FM) was higher with single-layered materials. Both overall force and net force (FI-FM) were significantly higher with 0.75 mm compared to those with a thickness of 0.50 mm. CONCLUSIONS: Multi-layered aligner materials exert lower forces compared to their single-layered counterparts. Additionally, increased thickness in aligners results in enhanced retention and greater force generation. For effective bodily tooth movement, thicker and single-layered rigid materials are preferred. CLINICAL RELEVANCE: This research provides valuable insights into the biomechanics of orthodontic aligners, which could have significant clinical implications for orthodontists. Orthodontists might use this information to more effectively tailor aligner treatments, considering the specific tooth movement required for each individual patient. In light of these findings, an exchangeable protocol for aligner treatment is suggested, which however needs to be proven clinically. This protocol proposes alternating between multi-layered and single-layered materials within the same treatment phase. This strategy is suggested to optimize treatment outcomes, particularly when planning for a bodily tooth movement.


Assuntos
Desenho de Aparelho Ortodôntico , Técnicas de Movimentação Dentária , Humanos , Fenômenos Biomecânicos , Resultado do Tratamento , Técnicas de Movimentação Dentária/métodos
5.
BMC Oral Health ; 24(1): 620, 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38807109

RESUMO

BACKGROUND: The mechanical properties of fully crystallized lithium aluminosilicate ceramics may be influenced by intraoral temperature variations and postmilling surface treatment. The purpose of this study is to explore the interplay among glazing, thermocycling, and the mechanical characteristics (namely, fracture toughness and hardness) of fully crystallized lithium aluminosilicate ceramics. METHODS: Bending bars (n = 40) cut from LisiCAD blocks (GC, Japan) were randomly assigned to glazed or unglazed groups (n = 20) and subjected to the single edge v-notch beam method to create notches. A glazing firing cycle was applied to the glazed group, while the unglazed group was not subjected to glazing. Half of the specimens (n = 10) from both groups underwent thermocycling before fracture toughness testing. The fracture toughness (KIC) was evaluated at 23 ± 1 °C using a universal testing machine configured for three-point bending, and the crack length was measured via light microscopy. Seven specimens per group were selected for the hardness test. Hardness was assessed using a Vickers microhardness tester with a 1 kg load for 20 s, and each specimen underwent five indentations following ISO 14705:2016. The Shapiro-Wilk and Kolmogorov-Smirnov tests were used to evaluate the normality of the data and a two-way ANOVA was utilized for statistical analysis. The significance level was set at (α = 0.05). RESULTS: Regardless of the thermocycling conditions, the glazed specimens exhibited significantly greater fracture toughness than did their unglazed counterparts (P < 0.001). Thermocycling had no significant impact on the fracture toughness of either the glazed or unglazed specimens. Furthermore, statistical analysis revealed no significant effects on hardness with thermocycling in either group, and glazing alone did not substantially affect hardness. CONCLUSIONS: The impact of glazing on the fracture toughness of LiSiCAD restorations is noteworthy, but it has no significant influence on their hardness. Furthermore, within the parameters of this study, thermocycling was found to exert negligible effects on both fracture toughness and hardness.


Assuntos
Silicatos de Alumínio , Cerâmica , Desenho Assistido por Computador , Dureza , Teste de Materiais , Cerâmica/química , Silicatos de Alumínio/química , Análise do Estresse Dentário , Propriedades de Superfície , Cristalização
6.
BMC Oral Health ; 24(1): 99, 2024 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-38233794

RESUMO

BACKGROUND: While conventional threaded implants (TI) have proven to be effective for replacing missing teeth, they have certain limitations in terms of diameter, length, and emergence profile when compared to customised root analogue implants (RAI). To further investigate the potential benefits of RAIs, the aim of this study was to experimentally evaluate the micromotion of RAIs compared to TIs. METHODS: A 3D model of tooth 47 (mandibular right second molar) was segmented from an existing cone beam computed tomography (CBCT), and a RAI was designed based on this model. Four RAI subgroups were fabricated as follows: 3D-printed titanium (PT), 3D-printed zirconia (PZ), milled titanium (MT), milled zirconia (MZ), each with a sample size of n = 5. Additionally, two TI subgroups (B11 and C11) were used as control, each with a sample size of n = 5. All samples were embedded in polyurethane foam artificial bone blocks and subjected to load application using a self-developed biomechanical Hexapod Measurement System. Micromotion was quantified by analysing the load/displacement curves. RESULTS: There were no statistically significant differences in displacement in Z-axis (the loading direction) between the RAI group and the TI group. However, within the RAI subgroups, PZ exhibited significantly higher displacement values compared to the other subgroups (p < 0.05). In terms of the overall total displacement, the RAI group showed a statistically significant higher displacement than the TI group, with mean displacement values of 96.5 µm and 55.8 µm for the RAI and TI groups, respectively. CONCLUSIONS: The RAI demonstrated promising biomechanical behaviour, with micromotion values falling within the physiological limits. However, their performance is less predictable due to varying anatomical designs.


Assuntos
Implantes Dentários , Humanos , Titânio , Zircônio , Software
7.
BMC Oral Health ; 24(1): 455, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38622680

RESUMO

BACKGROUND: The aim of this study is to evaluate the biomechanical behavior of the mesial and distal off-axial extensions of implant-retained prostheses in the posterior maxilla with different prosthetic materials using finite element analysis (FEA). METHODS: Three dimensional (3D) finite element models with three implant configurations and prosthetic designs (fixed-fixed, mesial cantilever, and distal cantilever) were designed and modelled depending upon cone beam computed tomography (CBCT) images of an intact maxilla of an anonymous patient. Implant prostheses with two materials; Monolithic zirconia (Zr) and polyetherketoneketone (PEKK) were also modeled .The 3D modeling software Mimics Innovation Suite (Mimics 14.0 / 3-matic 7.01; Materialise, Leuven, Belgium) was used. All the models were imported into the FE package Marc/Mentat (ver. 2015; MSC Software, Los Angeles, Calif). Then, individual models were subjected to separate axial loads of 300 N. Von mises stress values were computed for the prostheses, implants, and bone under axial loading. RESULTS: The highest von Mises stresses in implant (111.6 MPa) and bone (100.0 MPa) were recorded in distal cantilever model with PEKK material, while the lowest values in implant (48.9 MPa) and bone (19.6 MPa) were displayed in fixed fixed model with zirconia material. The distal cantilever model with zirconia material yielded the most elevated levels of von Mises stresses within the prosthesis (105 MPa), while the least stresses in prosthesis (35.4 MPa) were recorded in fixed fixed models with PEKK material. CONCLUSIONS: In the light of this study, the combination of fixed fixed implant prosthesis without cantilever using a rigid zirconia material exhibits better biomechanical behavior and stress distribution around bone and implants. As a prosthetic material, low elastic modulus PEKK transmitted more stress to implants and surrounding bone especially with distal cantilever.


Assuntos
Implantes Dentários , Zircônio , Humanos , Análise de Elementos Finitos , Maxila/cirurgia , Prótese Dentária Fixada por Implante , Análise do Estresse Dentário/métodos , Estresse Mecânico
8.
Artigo em Inglês | MEDLINE | ID: mdl-37565539

RESUMO

OBJECTIVES: Surgical guides are frequently used for dental implant placement. The aim of this study was to evaluate the impact of the 3D printing process itself and subsequent steam autoclaving on the dimensional stability of five different resin/printer combinations (RPCs). MATERIALS AND METHODS: Fifty identical surgical guides (10 per group) were produced consisting of five RPCs. Half of the guides (5 per group) were steam autoclaved with cycle 1 (121°C, 1 bar, 20.5 min) and the other half with cycle 2 (134°C, 2 bar, 5.5 min). All guides were scanned with a structured-light (SL) 3D scanner before (T0) and after (T1) autoclaving. Linear measurements along the x-, y-, and z-axes were performed at landmarks on the original STL file and on SL scans at T0 and T1, respectively. Wilcoxon signed-rank test, Kruskal-Wallis test, and linear mixed-effects models were performed, depending on the analysis. RESULTS: Three-dimensional printing was associated with significant dimensional alterations for all RPCs. Steam autoclaving using cycle 1 was associated with significant shrinkage in x- (1 RPC), y- (2 RPCs), and z-direction (2 RPCs), while cycle 2 was also associated with shrinkage in x- (2 RPCs), y- (1 RPC), and z-direction (1 RPC). One resin did not present any dimensional changes independently of the cycle. CONCLUSIONS: The majority of the guides presented minor but significant shrinkage due to 3D printing itself and both steam autoclaving cycles, the extent varied between different RPCs. Whether these changes compromise implant placement accuracy remains to be investigated.

9.
J Mater Sci Mater Med ; 34(11): 60, 2023 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-37962680

RESUMO

Half a million different plant species are occurring worldwide, of which only 1% has been phytochemically considered. Thus, there is great potential for discovering novel bioactive compounds. In dentistry, herbal extracts have been used as antimicrobial agents, analgesics, and intracanal medicaments. Glass-ionomer cement (GIC) and bioactive glass (BAG) are attractive materials in dentistry due to their bioactivity, adhesion, and remineralisation capabilities. Thus, this review summarizes the evidence around the use of phytotherapeutics in dental glass-based materials. This review article covers the structure, properties, and clinical uses of GIC and BAG materials within dentistry, with an emphasis on all the attempts that have been made in the last 20 years to enhance their properties naturally using the wisdom of traditional medicines. An extensive electronic search was performed across four databases to include published articles in the last 20 years and the search was concerned only with the English language publications. Publications that involved the use of plant extracts, and their active compounds for the green synthesis of nanoparticles and the modification of GIC and BAG were included up to May 2023. Plant extracts are a potential and effective candidate for modification of different properties of GIC and BAG, particularly their antimicrobial activities. Moreover, natural plant extracts have shown to be very effective in the green synthesis of metal ion nanoparticles in an ecological, and easy way with the additional advantage of a synergistic effect between metal ions and the phytotherapeutic agents. Medicinal plants are considered an abundant, cheap source of biologically active compounds and many of these phytotherapeutics have been the base for the development of new lead pharmaceuticals. Further research is required to assess the safety and the importance of regulation of phytotherapeutics to expand their use in medicine.


Assuntos
Medicina Herbária , Nanopartículas Metálicas , Extratos Vegetais , Cimentos de Ionômeros de Vidro , Odontologia
10.
Clin Oral Investig ; 27(7): 3673-3682, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37017760

RESUMO

OBJECTIVES: Although a new super-quick setting polyether impression material has been commercially recently introduced, its properties have not been yet reported. Thus, it was the aim of this study to assess the dimensional stability, tear strength, and elastic recovery of the new material and to compare it with another commonly used polyether and polyvinyl siloxane. MATERIALS AND METHODS: A new super-quick set polyether, a regular set polyether and a polyvinylsiloxane (PVS) impression material have been used in the study. Dimensional changes were measured using a modified mold as per ISO 4823:2000 after 1 h and 7 days. Tear strength was evaluated by subjecting specimens to tension until failure with a crosshead speed of 250 mm/min. Elastic recovery was measured by deforming specimens using a materials testing machine to a height of 16 mm (20% strain). The change in length (ΔL) was measured afterwards and elastic recovery was calculated in percentages. RESULTS: Dimensional changes of the super quick and regular set polyether were comparable in both the vertical and horizontal dimensions after 24 h and 7 days. All the tested materials showed dimensional change values far below the maximum accepted ISO requirement (1.5%). The super quick setting polyether showed significantly improved tear strength (4.9 N/mm) in comparison to the regular set polyether (3.5 N/mm) and similar to PVS (5.2 N/mm). The elastic recovery of PVS (99.6%) was the highest among all the groups. CONCLUSIONS AND CLINICAL RELEVANCE: The newly available super-fast set polyether offers a great potential for a reduced chair side time and comfort for both, the patient and the dentist. Super quick polyether showed as well improved tear strength, which is considered one of the shortcomings of the regular set polyether. In addition, the new polyether was as accurate as the regular set polyether and with good elastic recovery.


Assuntos
Materiais para Moldagem Odontológica , Siloxanas , Humanos , Polivinil , Teste de Materiais
11.
Clin Oral Investig ; 27(10): 6125-6133, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37615777

RESUMO

OBJECTIVES: The aim of this study was to evaluate the effect of cyclic mechanical loading on the fracture resistance of 3D-printed zirconia crowns in comparison to milled zirconia crowns. MATERIALS AND METHODS: Monolithic zirconia crowns (n = 30) were manufactured using subtractive milling (group M) and 3D additive printing (group P). Nine samples of each group were fractured under one-time loading while the other 6 samples were subjected to cyclic loading for 1.2 million cycles before being subjected to one-time loading until fracture. Scanning electron microscope (SEM) fractographic analysis was carried out on fractured fragments of representative samples. RESULTS: The mean for fracture resistance of group M was 1890 N without cyclic loading and 1642 N after being subjected to cyclic loading, and they were significantly higher than that of group P (1658 N and 1224 N respectively). CONCLUSIONS: The fabrication technique and cyclic loading affect the fracture resistance of zirconia crowns. Although the fracture resistance values for the 3D-printed crowns were lower than those of the milled, still they are higher than the masticatory forces and thus could be considered being clinically acceptable. CLINICAL RELEVANCE: Concerning fracture resistance, 3D-printed crowns can withstand the masticatory forces for the long term without any cracks or failure.

12.
Clin Oral Investig ; 27(6): 2653-2665, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36574045

RESUMO

OBJECTIVES: To evaluate and compare fracture resistance, translucency, and color reproducibility, as well as the effect of aging on the fracture load and color stability of novel monolithic CAD/CAM ceramics. MATERIALS AND METHODS: One hundred crowns of uniform thickness were milled from five ceramic blocks (n = 20): partially crystallized lithium disilicate (PLD) and fully crystallized lithium disilicate (FLD), lithium metasilicate (LMS), 4Y-TZP (SMZ), and 5Y-TZP (UMZ) monolithic zirconia. PLD crowns were glazed, LMS was fired, and FLD was polished. SMZ and UMZ crowns were sintered and polished. Crowns were adhesively cemented to epoxy dies. Half of the crowns (n = 10) were subjected to 1.200.000 load cycles with thermal cycling. Color space values L, a, b defined by the Commission Internationale de l´Eclairage (CIELAB) were measured before and after aging, and (∆E) was calculated. Both aged and non-aged specimens were loaded until fracture in a universal testing machine and the fracture load was recorded. X-ray diffraction (XRD) and scanning electron microscope (SEM) fractographic analysis were carried out on fractured fragments of representative samples. For translucency and color reproducibility, 50 rectangular-shaped specimens were fabricated and processed as described previously. Color values were measured over black and white backgrounds, and the translucency parameter (TP) was computed. Using the shade verification mode, (∆E) to shade A3 was calculated. Data were statistically analyzed using one-way and two-way ANOVA, and t-test. RESULTS: Aging did not affect fracture resistance significantly (p > 0.05). The highest mean fracture load was obtained for the SMZ and UMZ. A significant color change was observed after aging in all groups. The highest TP was noted for FLD. SMZ and UMZ had the best shade match. CONCLUSIONS: Zirconia showed higher fracture resistance and color stability than lithium silicate ceramics. Lithium silicate ceramics were more translucent. The experimental FLD demonstrated high translucency. CLINICAL RELEVANCE: Tested ceramics showed sufficient stability to withstand masticatory forces. Characterization of final restorations might be mandatory for better color match.


Assuntos
Estética Dentária , Lítio , Humanos , Cerâmica , Cor , Desenho Assistido por Computador , Coroas , Porcelana Dentária , Análise do Estresse Dentário , Teste de Materiais , Reprodutibilidade dos Testes , Silicatos , Propriedades de Superfície , Zircônio
13.
Clin Oral Investig ; 27(11): 6677-6688, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37775587

RESUMO

OBJECTIVES: Disinfection of alginate impression materials is a mandatory step to prevent cross-infection in dental clinics. However, alginate disinfection methods are time-consuming and exert a negative impact on accuracy and mechanical properties. Thus, this study aimed to prepare disinfecting agents (CHX and AgNO3) and silver nanoparticles reduced by a natural plant extract to produce a self-disinfecting dental alginate. METHODS: Conventional alginate impression material was used in this study. Silver nitrate (0.2% AgNO3 group) and chlorohexidine (0.2% CHX group) solutions were prepared using distilled water, and these solutions were later employed for alginate preparation. Moreover, a 90% aqueous plant extract was prepared from Boswellia sacra (BS) oleoresin and used to reduce silver nitrate to form silver nanoparticles that were incorporated in the dental alginate preparation (BS+AgNPs group). The plant extract was characterized by gas chromatography/mass spectrometry (GC/MS) analysis while green-synthesized silver nanoparticles (AgNPs) were characterized by UV-visible (UV-vis) spectroscopy and scanning electron microscopy (SEM). An agar disc diffusion assay was used to test the antimicrobial activity against Candida albicans, Streptococcus mutans, Escherichia coli, methicillin-resistant and susceptible Staphylococcus aureus strains, and Micrococcus luteus. Agar plates were incubated at 37 ± 1 °C for 24 h to allow microbial growth. Diameters of the circular inhibition zones formed around each specimen were measured digitally by using ImageJ software. RESULTS: Chemical analysis of the plant extract revealed the presence of 41 volatile and semi-volatile active compounds. UV-Vis spectrophotometry, SEM, and EDX confirmed the formation of spherical silver nanoparticles using the BS extract. CHX, AgNO3, and the BS+AgNPs modified groups showed significantly larger inhibition zones than the control group against all tested strains. BS+AgNPs and CHX groups showed comparable efficacy against all tested strains except for Staphylococcus aureus, where the CHX-modified alginate had a significantly higher effect. CONCLUSIONS AND CLINICAL RELEVANCE: CHX, silver nitrate, and biosynthesized silver nanoparticles could be promising inexpensive potential candidates for the preparation of a self-disinfecting alginate impression material without affecting its performance. Green synthesis of metal nanoparticles using Boswellia sacra extract could be a very safe, efficient, and nontoxic way with the additional advantage of a synergistic action between metal ions and the phytotherapeutic agents of the plant extract.


Assuntos
Alginatos , Nanopartículas Metálicas , Alginatos/farmacologia , Desinfecção , Nitrato de Prata/farmacologia , Nanopartículas Metálicas/química , Ágar/farmacologia , Cromatografia Gasosa-Espectrometria de Massas , Prata , Extratos Vegetais/farmacologia , Staphylococcus aureus , Nanotecnologia/métodos , Antibacterianos/farmacologia , Testes de Sensibilidade Microbiana
14.
Clin Oral Investig ; 27(1): 115-124, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35989373

RESUMO

OBJECTIVES: To design a finite element (FE) model that might facilitate understanding of the complex mechanical behavior of orthodontic aligners. The designed model was validated by comparing the generated forces - during 0.2-mm facio-lingual translation of upper left central incisor (Tooth 21) - with the values reported by experimental studies in literature. MATERIALS AND METHODS: A 3D digital model, obtained from scanning of a typodont of upper jaw, was imported into 3-matic software for designing of aligners with different thicknesses: 0.4, 0.5, 0.6, 0.7 mm. The model was exported to Marc/Mentat FE software. Suitable parameters for FE simulation were selected after a series of sensitivity analyses. Different element classes of the model and different rigidity values of the aligner were also investigated. RESULTS: The resultant maximum forces generated on facio-lingual translation of Tooth 21 were within the range of 1.3-18.3 N. The force was direction-dependent, where lingual translation transmitted higher forces than facial translation. The force increases with increasing the thickness of the aligner, but not linearly. We found that the generated forces were almost directly proportional to the rigidity of the aligner. The contact normal stress map showed an uneven but almost repeatable distribution of stresses all over the facial surface and concentration of stresses at specific points. CONCLUSIONS: A validated FE model could reveal a lot about mechanical behavior of orthodontic aligners. CLINICAL RELEVANCE: Understanding the force systems of clear aligner by means of FE will facilitate better treatment planning and getting optimal outcomes.


Assuntos
Desenho de Aparelho Ortodôntico , Técnicas de Movimentação Dentária , Análise de Elementos Finitos , Simulação por Computador , Computadores
15.
Clin Oral Investig ; 27(2): 797-805, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36625961

RESUMO

OBJECTIVE: To identify tooth mobility (TM) by time-dependent tooth displacement using an electronic intra-oral loading device (ILD) in periodontally healthy and periodontally compromised patients. MATERIALS AND METHODS: Twenty-eight untreated periodontitis and 20 periodontally healthy patients [25 female and 26 male; ages: 20-81 years], contributing with 68 teeth (periodontitis: nteeth = 28; non-periodontitis: nteeth = 40), participated in the study. TM was measured in vivo by displacing central or lateral incisors to a maximum of 0.2 mm orally over durations of 0.5 s, 1 s, and 10 s with the ILD. The maximum force (Fmax) was extracted from the measured force/deflection curves for every single measurement. RESULTS: Differences in TM-ILD values were found for periodontitis as compared to non-periodontitis patients derived from the same loading durations (differences of 3.9 (0.5 s), 3.1 (1 s), 2.8 (10 s), (95% CI for 0.5 s (1.2-6.7), p = 0.024; 1 s (1.4-6.0), p = 0.067; 10 s (0.2-5.3), p = 0.001), rejecting the null hypothesis of no difference (T-test) for durations of 0.5 and 10 s. There was a significant correlation of TM-ILD (Fmax) with BOP at 0.5 s (- 0.52) and with attachment loss at all time durations (- 0.47 at 0.5 s; - 0.57 at 1 s; - 0.47 at 10 s). CONCLUSIONS: This clinical investigation could demonstrate that time-dependent tooth displacements using a new computerized electronic device were associated with attachment loss and bleeding on probing. CLINICAL RELEVANCE: ILD can improve the monitoring of tooth mobility, as TM-ILD values reflect qualitative (inflammatory status interpreted by BOP) and quantitative parameters (interpreted as the amount of CAL loss) of periodontal disease.


Assuntos
Doenças Periodontais , Periodontite , Mobilidade Dentária , Humanos , Masculino , Feminino , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Periodontite/complicações , Periodonto , Doenças Periodontais/complicações , Incisivo , Perda da Inserção Periodontal
16.
J Craniofac Surg ; 34(5): e453-e458, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36941242

RESUMO

OBJECTIVES: Eagle syndrome is a rare disease caused by an elongated styloid process (type I) or ossified stylohyoid ligament (type II) and causes a heterogeneous symptom complex, ranging from pain in the throat and neck to neurological symptoms and neurovascular entrapment. The 2 different types present differing shapes and ultrastructures and cause different symptoms. This study aimed to distinguish the 2 types by investigating the structures by micro-computed tomography. METHODS: Micro-computed tomography was performed and evaluated in n=10 resected styloid processes from patients diagnosed with Eagle syndrome. The tissues were measured for their shape, ratio of soft tissue and bone amounts, bone volume, and ultrastructure, and compared within the groups. RESULTS: The shapes of the different types were different and the ultrastructure differed between the 2 groups, with an absence of trabecular architecture in type II. The area of bone to nonbone tissues in type I samples was significantly higher compared with type II ( P =0.007). Alike these results, the bone volume and bone-to-soft tissue ratio were significantly higher in type I compared with type II ( P =0.009). CONCLUSIONS: The findings suggest that both the popular theories (hyperplasia and metaplasia) may be probable but each solely valid for 1 type of Eagle. Type I may derive from bone hyperplasia with cancellous bone formation and rather high bone density in the elongated styloid process. Type II most likely originates from ligament metaplasia into bone without a compact structure.


Assuntos
Ossificação Heterotópica , Humanos , Microtomografia por Raio-X , Hiperplasia/patologia , Ossificação Heterotópica/diagnóstico por imagem , Ossificação Heterotópica/cirurgia , Ossificação Heterotópica/complicações , Osso Temporal/anormalidades , Cervicalgia/etiologia
17.
BMC Oral Health ; 23(1): 105, 2023 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-36797710

RESUMO

Biomimetics is a branch of science that explores the technical beauty of nature. The concept of biomimetics has been brilliantly applied in famous applications such as the design of the Eiffel Tower that has been inspired from the trabecular structure of bone. In dentistry, the purpose of using biomimetic concepts and protocols is to conserve tooth structure and vitality, increase the longevity of restorative dental treatments, and eliminate future retreatment cycles. Biomimetic dental materials are inherently biocompatible with excellent physico-chemical properties. They have been successfully applied in different dental fields with the advantages of enhanced strength, sealing, regenerative and antibacterial abilities. Moreover, many biomimetic materials were proven to overcome significant limitations of earlier available generation counterpart. Therefore, this review aims to spot the light on some recent developments in the emerging field of biomimetics especially in restorative and regenerative dentistry. Different approaches of restoration, remineralisation and regeneration of teeth are also discussed in this review. In addition, various biomimetic dental restorative materials and tissue engineering materials are discussed.


Assuntos
Biomimética , Dente , Humanos , Engenharia Tecidual/métodos , Assistência Odontológica , Materiais Biocompatíveis/uso terapêutico
18.
BMC Oral Health ; 23(1): 448, 2023 07 04.
Artigo em Inglês | MEDLINE | ID: mdl-37403169

RESUMO

BACKGROUND: This study aimed to evaluate and compare the marginal gap using two different methods and the internal fit of 3D printed and zirconia crowns. METHODS: 3Y-TZP zirconia crowns (n = 20) were manufactured using subtractive milling (group M) and 3D printed (group P). The marginal gap was measured at 60 points using vertical marginal gap technique (VMGT). On the other hand, the silicone replica technique (SRT) was used to evaluate the internal fit and was divided into 4 groups: marginal gap, cervical gap, axial gap, and occlusal gap where the thickness of light impression was measured at 16 references. The numerical data was tested for normality using Shapiro-Wilk's test. They were found to be normally distributed and were analyzed using an independent t-test. RESULTS: Using VMGT, group P had significantly higher mean marginal gap values of 80 ± 30 µm compared to group M = 60 ± 20 µm (p < 0.001). Also, with the SRT, the marginal gap of group P (100 ± 10 µm) had significantly higher values compared to group M (60 ± 10 µm). The internal fit showed significant difference between the tested groups except for Axial Gap. CONCLUSIONS: Although milled crowns showed better results. The 3D printed zirconia crowns offer clinically acceptable results in terms of marginal adaptation and internal fit. Both VMGT and SRT are reliable methods for the assessment of the marginal gap.


Assuntos
Desenho Assistido por Computador , Adaptação Marginal Dentária , Humanos , Planejamento de Prótese Dentária , Coroas , Impressão Tridimensional
19.
BMC Oral Health ; 23(1): 207, 2023 04 07.
Artigo em Inglês | MEDLINE | ID: mdl-37029396

RESUMO

BACKGROUND: The aim of the study was to investigate the effect of material and occlusal preparation design on the internal fit and marginal gap of endocrowns made of Polyether ether ketone (PEEK) and lithium disilicate. METHODS: 32 endocrowns were fabricated on prepared mandibular molars and divided into two groups (n = 16) according to the material. Group L: lithium disilicate and Group P: PEEK. Each group was further subdivided into two subgroups (n = 8) according to the occlusal preparation design: full occlusal coverage (LF and PF) and partial occlusal coverage (LP and PP). Samples were analyzed using microcomputed tomography (µCT) with a voxel size of 6 µm to evaluate internal fit, and an optical microscope was used to evaluate the marginal gap. Data were collected, tabulated, and statistically analyzed. Numerical data were described as mean and standard deviation and compared using the ANOVA test. The level of significance was set at α P ≤ 0.05. RESULTS: All groups' internal fit and marginal gaps values were within the acceptable clinical range. However, the lithium disilicates group recorded statistically significantly higher mean internal gap values than the PEEK groups. Regardless of the material, the difference between the two occlusal designs was not statistically significant in both internal fit and marginal gap records. CONCLUSION: Within the limitations of this study, PEEK endocrown restorations revealed better internal fit and marginal gap than lithium disilicate endocrown restorations. The marginal and internal fit of both lithium disilicate and PEEK endocrown restorations were within the clinically acceptable range. The occlusal preparation design had no influence on the internal fit and marginal gap of the endocrown restoration.


Assuntos
Cerâmica , Coroas , Humanos , Microtomografia por Raio-X , Desenho Assistido por Computador , Adaptação Marginal Dentária , Planejamento de Prótese Dentária/métodos , Éteres , Teste de Materiais
20.
Clin Oral Investig ; 26(4): 3707-3719, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34935067

RESUMO

OBJECTIVES: The aim of the study was to determine differences between Locator and CM LOC attachment systems regarding patient satisfaction and wear of the abutments and their inserts. Plaque accumulation onto the polyetherketoneketone (PEKK) framework and polymethylmethacrylate (PMMA) was investigated for the implant-supported overdentures. METHODS: Seventeen edentulous patients were randomised to receive either Locator or CM LOC system for the first year. The total number of implants was 53. After the randomisation, 25 implants received Locator system, and 28 implants received CM LOC system in the first year. After a period of 12 months, the attachment system was exchanged from either Locator to CM LOC or vice versa. Oral Health Impact Profile (OHIP-14) questionnaires were used to evaluate patient satisfaction, chewing comfort, and pressure lesions. Prosthesis hygiene on the PMMA and PEKK surfaces was evaluated by using Stark plaque index. After the exchange of the abutments, they were stored until the end of the 24 months, and the surface wear of the abutments was analysed using a scanning electron microscope. RESULTS: Three patients (10 implants) died shortly before the end of the first year. Two patients (7 implants) received only Locator system since CM LOC was not indictable for their implant system. Patient's satisfaction was increased when the attachment system was changed from Locator to CM LOC after 12 months of wearing time. Chewing ability and comfort were increased when the attachment system was changed from CM LOC to Locator after 12-month wearing time. There was no influence of the change of the attachment system on pressure lesions. The observed plaque accumulation was higher on the PMMA than on the PEKK surface. For the 8 investigated Locator abutments, the wear was within low and middle level. For the 28 investigated CM LOC abutments, the wear was within middle and high level for the terminal implants and between low and middle for the central implants (for patients who received 4 implants). CONCLUSIONS: Patient's satisfaction and wearing comfort can be improved with implant-supported overdentures with CM LOC abutments in comparison to Locator. There was no clear difference between both attachment systems concerning the chewing ability of the patients. Plaque accumulation was observed on both attachment systems in different areas. Plaque accumulation on PEKK surface was less than on PMMA surface. CLINICAL RELEVANCE: The CM LOC attachment system offers stable and comfortable wearing conditions for implant-supported overdentures. The use of PEKK as a framework material could reduce the incidence of pressure lesions.


Assuntos
Implantes Dentários , Arcada Edêntula , Benzofenonas , Prótese Dentária Fixada por Implante , Retenção de Dentadura , Revestimento de Dentadura , Humanos , Mandíbula , Mucosa , Projetos Piloto , Polímeros
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA