Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Langmuir ; 27(1): 187-95, 2011 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-21141900

RESUMO

Nitrogen adsorption isotherms of silicas and other oxidic materials are distorted by the presence of micropore adsorption and capillary condensation. This distortion affects the determination of the specific area of the material, depending on the chosen calculation procedure. Correction of the initial (total) isotherm for micropore capacity decreases or eliminates this source of error to give a useful estimate of the external surface area. In the present work, 26 silica-based adsorbent materials were studied to obtain total and external specific surface areas by the Brunauer-Emmett-Teller (BET), I-point, and α-plot procedures, using the micropore capacities from the α-plots to obtain the corrected (external) isotherms. Errors in the specific surface areas due to the presence of micropores are given by the equation ΔsA = 3.267 (m(2)/cm(3) STP) sV(mic), where sA is the specific surface area in m(2)/g and sV(mic) is the micropore capacity in cm(3) STP/g. A consistent set of conversion factors was obtained by which the external specific surface area obtained using one of these procedures can be converted, with part-per-thousand precision, to either of the others. Although the I-point procedure presents the advantage of not requiring a defined p/p(0) range, the α-plot procedure is recommended for routine determinations of external specific areas of silicas and other oxidic materials, except for cases in which the shapes of the adsorption isotherms of the sample and the reference differ significantly from one another in the p/p(0) range used for the determination.

2.
J Chromatogr A ; 1191(1-2): 90-8, 2008 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-18243228

RESUMO

To further extend our studies in the search for reversed phases with enhanced durability at high pH, zirconized silica has now been explored as an alternative support. The synthesis of the new stationary phases involves silanization of a zirconium-modified silica support with a C(18) trifunctional silane, followed by endcapping. The chromatographic properties of the C(18) phases based on zirconized silica are similar to their titanized silica counterparts. Accelerated high pH stability tests, using phosphate mobile phases and elevated temperature, have shown that the zirconized silica phases have promising advantages not only over similarly prepared non-metalized phases but also over titanized silica C(18) phases.


Assuntos
Cromatografia Líquida de Alta Pressão/instrumentação , Silanos/síntese química , Dióxido de Silício/química , Zircônio/química , Fenômenos Químicos , Físico-Química , Estabilidade de Medicamentos , Concentração de Íons de Hidrogênio , Espectroscopia de Ressonância Magnética , Espectrometria por Raios X , Espectrofotometria Infravermelho
3.
J Chromatogr A ; 1156(1-2): 51-9, 2007 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-17084847

RESUMO

The preparation of stationary phases with enhanced chemical stability in alkaline eluents has been the principal objective of many chromatographers. New and improved silica substrates and advanced chemical modification methods are among the possibilities being investigated to reach this objective. The present work has evaluated these two possibilities for new stationary phases. First, the silica surface was modified by reaction with zirconium tetrabutoxide to produce zirconized silica particles having about 21% (w/w) of zirconium. Then poly(methyltetradecylsiloxane) (PMTDS) was immobilized onto this surface using different doses (50-120 kGy) of gamma radiation. These new phases were characterized using elemental analysis and infrared and solid-state (29)Si-nuclear magnetic resonance (NMR) spectroscopies. These new stationary phases presented column efficiencies of about 68,000 plates m(-1), symmetric peaks for apolar compounds and retention factors that depend on the irradiation dose and show improved stability in high pH mobile phases. The separation of several pharmaceuticals at pH 11 is presented.


Assuntos
Cromatografia Líquida de Alta Pressão/instrumentação , Dióxido de Silício/efeitos da radiação , Siloxanas/efeitos da radiação , Acetaminofen/isolamento & purificação , Alprazolam/isolamento & purificação , Derivados de Benzeno/isolamento & purificação , Ibuprofeno/isolamento & purificação , Lorazepam/isolamento & purificação , Espectroscopia de Ressonância Magnética , Siloxanas/síntese química , Siloxanas/química , Espectrofotometria Infravermelho , Uracila/isolamento & purificação , Zircônio
4.
J Chromatogr A ; 1156(1-2): 60-7, 2007 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-17462660

RESUMO

Batches of poly(methyloctylsiloxane) (PMOS)-loaded silica were prepared by deposition from a solution of PMOS into the pores of HPLC silica. Portions of PMOS-loaded silica were subjected to a thermal treatment at 100 degrees C for 24h (condition 1) in a tube furnace under a nitrogen atmosphere. After that, the material was heated for 4h at higher temperatures (150-400 degrees C) (condition 2). Heating at higher temperatures produces polymer bilayers. Non-immobilized and thermally treated stationary phases were characterized by percent carbon, (29)Si cross-polarization magic angle spinning nuclear magnetic resonance spectroscopy and reversed-phase chromatographic performance. The results show that thermal treatment between 150 and 300 degrees C accelerates the immobilization process, possibly due to some bond breaking of the polysiloxane, with formation of strong linkages to the surface of the support, resulting in more complete coverage of the silica. The chromatographic results show an improvement of efficiency with the increase of the temperature of condition 2 up to 300 degrees C and an increase in the resolution of the components, mainly for the phase heated at 300 degrees C. Such results demonstrate that a two-step thermal treatment (100 degrees C then 150-300 degrees C) produces stationary phases with good properties for use in reversed-phase high-performance liquid chromatography.


Assuntos
Cromatografia Líquida de Alta Pressão/instrumentação , Siloxanas/síntese química , Temperatura Alta , Dióxido de Silício/química
5.
J Chromatogr A ; 1119(1-2): 135-9, 2006 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-16430910

RESUMO

Reversed phases for high-performance liquid chromatography (RP-HPLC) were obtained by thermal immobilization of polysiloxanes having different length chains (C1, C8 and C14) onto HPLC silica particles. The importance both of percent loading of the stationary phase promoted by each immobilization procedure and of the length of the lateral chain of the polymer on the chromatographic performances of the phases obtained is compared and discussed.


Assuntos
Cromatografia Líquida de Alta Pressão/instrumentação , Cromatografia Líquida de Alta Pressão/métodos , Dióxido de Silício/química , Siloxanas/química , Acenaftenos/isolamento & purificação , Compostos de Anilina/isolamento & purificação , Derivados de Benzeno/isolamento & purificação , Temperatura Alta , Interações Hidrofóbicas e Hidrofílicas , Naftalenos/isolamento & purificação , Fenol/isolamento & purificação , Uracila/isolamento & purificação
6.
J Chromatogr A ; 1122(1-2): 114-22, 2006 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-16696991

RESUMO

The modification of silica with zirconium oxide followed by sorption and thermal immobilization of poly(methyltetradecylsiloxane) (PMTDS) is used to prepare a reversed stationary phase for high-performance liquid chromatography. The thermal immobilization of PMTDS on zirconized silica was optimized using a central composite design. The new stationary phase was characterized by spectroscopic and chromatographic methods. Stationary phases with good reproducibility and good chromatographic performance for various compounds were obtained. PMTDS thermally immobilized on zirconized silica presented quite significant chemical stability at pH 10 and 50 degrees C.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Polímeros/química , Dióxido de Silício/química , Siloxanas/química , Zircônio/química , Estrutura Molecular , Polienos , Polímeros/síntese química , Reprodutibilidade dos Testes , Siloxanas/síntese química , Temperatura , Termogravimetria/métodos
7.
J Chromatogr A ; 1114(1): 45-52, 2006 May 05.
Artigo em Inglês | MEDLINE | ID: mdl-16515790

RESUMO

To extend pH stability, protective metal oxide layers, such as titanium oxide, that are more stable in alkaline medium, can be chemically bonded to the chromatographic silica surface prior to reaction with silanes. In the present work, the influence of the titanium oxide content on the chromatographic performance was investigated by synthesizing a C18 phase onto a doubly-titanized silica support and comparing its chromatographic performance with a C18 phase on singly-titanized silica. The Engelhardt and Tanaka test mixtures were used for chromatographic characterizations using short HPLC columns. The column lifetimes of these titanized phases were also compared by performing accelerated aging tests at 50 degrees C using aggressive phosphate mobile phases at pH 10.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Concentração de Íons de Hidrogênio , Titânio/química , Cromatografia Líquida de Alta Pressão/instrumentação , Espectroscopia de Ressonância Magnética
8.
J Chromatogr A ; 1075(1-2): 87-94, 2005 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-15974121

RESUMO

This work describes the preparation and characterization of six stationary phases for high-performance liquid chromatography (HPLC) obtained by deposition of poly(dimethylsiloxane) (PDMS) in HPLC silica particles, followed by immobilization using different processes (thermal treatments, thermal treatment + microwave irradiation, self-immobilization + gamma irradiation and self-immobilization + microwave irradiation). The chromatographic parameters of all the phases were evaluated with a mixture of test compounds having varied natures (acid, basic and neutral). The stability of one of these phases was evaluated in both a neutral mobile phase and a higher pH mobile phase used at an elevated temperature, with promising results.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Dimetilpolisiloxanos/química , Dióxido de Silício/química , Silicones/química , Concentração de Íons de Hidrogênio
9.
J Chromatogr A ; 1087(1-2): 29-37, 2005 Sep 16.
Artigo em Inglês | MEDLINE | ID: mdl-16130694

RESUMO

A new stationary phase containing embedded urea groups (-NH-C(O)-NH-) was prepared by a procedure based on the synthesis of a trifunctional C18 urea-alkoxysilane, followed by modification of titanized silica and further endcapping to evaluate if the embedded group would minimize the higher retention and tailing for basic compounds seen with C18 titanized silica phases. Infrared, 13C and 29Si spectroscopies were employed to characterize the C18-urea titanized silica phase. Chromatographic evaluations used hydrophobic, polar and basic compounds to verify the effects of the polar urea groups embedded in the C18 urea phase. The chromatographic parameters, especially for the separation of basic compounds, compare favorably with those obtained on a C18 titanized silica stationary phase, prepared by silanization of titanized silica with octadecyltrimethoxysilane.


Assuntos
Dióxido de Silício/química , Titânio/química , Varredura Diferencial de Calorimetria , Espectroscopia de Ressonância Magnética , Espectrometria de Massas
10.
J Chromatogr A ; 1073(1-2): 155-62, 2005 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-15909517

RESUMO

To enhance the high pH stability of silica based reversed phases, chemically bonded octadecyl phases were prepared through silanization of titanized silica particles containing approximately 14% titanium oxide on the surface. The present work describes some spectroscopic characterizations using infrared, solid-state 13C and 29Si nuclear magnetic resonance (NMR) and X-ray absorption spectroscopy (XAS). Chromatographic characterizations for the titanized phase as well as for a conventional C18 phase, based on the same silica support without titanization, are also described using three different test mixtures containing neutral, polar and basic compounds. After an artificial stability test at pH 10, the titanized phase was again characterized by elemental and X-ray fluorescence analyses to determine the remaining carbon and titanium contents. As an application to real world samples, the separation of some herbicides and highly basic drugs using buffered mobile phases are also shown.


Assuntos
Cromatografia por Troca Iônica/instrumentação , Dióxido de Silício/química , Titânio/química , Cromatografia por Troca Iônica/métodos , Concentração de Íons de Hidrogênio
11.
J Chromatogr A ; 1073(1-2): 147-53, 2005 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-15909516

RESUMO

This work describes the preparation of an anion-exchange phase based on silica, using a two-step modification process. First, 10 microm Davisil silica particles were silanized with chloropropyltrimethoxysilane to yield chloropropyl silica. The modified silica was then reacted with pyridine to produce positively charged propylpyridinium groups on the surface, the anion-exchange sites. The phase was characterized by thermogravimetric analysis and infrared and solid state 13C and 29Si NMR spectroscopies. HPLC separations of common inorganic anions, including chloride, nitrite, bromide and nitrate, were performed using 150 x 3.9 HPLC columns packed with the phase, using a phthalate buffer solution as mobile phase with non-suppressed conductivity detection. Efficiency and resolution were calculated and the results show that the new phase has significant promise for the analysis of these anions in environmental samples.


Assuntos
Resinas de Troca Aniônica , Cromatografia Líquida de Alta Pressão/instrumentação , Cromatografia por Troca Iônica/instrumentação , Eletroquímica , Espectrofotometria Infravermelho
12.
J Colloid Interface Sci ; 291(2): 353-60, 2005 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-15996677

RESUMO

Kinetic adsorption isotherms were obtained by gravimetric determination of water adsorption into fully hydroxylated mesoporous silicas using samples exposed to controlled humidity air at 22+/-2 degrees C. Twenty kinetic isotherms at several relative humidities (11, 33, 43, 51, 75, and 85%) were obtained with 11 different batches of silica using this simple procedure to obtain quantitative information on the formation of H2O adsorbates. The H2O surface concentrations obtained from the plateau data of individual kinetic adsorption isotherms at 43 and 51% RH, typically precise to about +/-1%, show that a complete monolayer is formed with negligible second-layer adsorption at these relative humidities. This monolayer has a surface concentration of 7.68+/-0.30 micromol H2O/m2, which is lower than the quasi-equilibrium concentration at these relative humidities obtained by the conventional equilibrium-isotherm procedure. Comparison with the Kiselev-Zhuravlev concentration of silanol groups on fully hydroxylated silicas (7.6+/-0.8 micromol SiOH/m2) confirms 1:1 H2O:SiOH stoichiometry of this monolayer. The presence of partial-layer structures at 2.85+/-0.1 and 5.7+/-0.1 micromol H2O/m2 is suggested by isotherms at 11 and 33% RH, respectively, while a bilayer at approximately 14+/-1 micromol H2O/m2 is suggested by kinetic isotherms at 75 and 85% RH.

13.
J Chromatogr A ; 987(1-2): 93-101, 2003 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-12613801

RESUMO

Several reversed-phase materials for high-performance liquid chromatography were obtained by deposition of poly(methyloctylsiloxane) (PMOS) on HPLC silica particles, followed by immobilization using different procedures. Each phase had characteristic physicochemical and chromatographic properties. The present work evaluates the stability of these phases with both neutral and basic mobile phases. All of the stationary phases were quite stable to neutral mobile phase, with less stability at higher pH. However, one thermally immobilized phase presented high stability even at an elevated temperature with a pH 10.0 mobile phase.


Assuntos
Cromatografia Líquida de Alta Pressão/instrumentação , Polímeros/química , Dióxido de Silício/química , Siloxanas/química , Microscopia Eletrônica de Varredura
14.
J Chromatogr A ; 948(1-2): 109-19, 2002 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-12831188

RESUMO

This work describes the chromatographic characterization of stationary phases prepared by deposition of poly(methyloctylsiloxane) (PMOS) on silica followed by immobilization using one of several different processes: thermal treatments (120 or 220 degrees C for 4 h), microwave irradiation (495 W for 15 min), gamma radiation (dose of 80 kGy) or self-immobilization. This evaluation was based on the chromatographic parameters of several test solutes. The stationary phases immobilized at 220 degrees C and which underwent self-immobilization were not appropriate for chromatographic use but the other immobilized phases presented chromatographic performances similar in most respects to a commercial phase (Rainin C8) while the peak characteristics of the basic probe were significantly better with these phases.


Assuntos
Polímeros/química , Siloxanas/química , Carbono/química , Fenômenos Químicos , Físico-Química , Cromatografia Líquida de Alta Pressão , Raios gama , Indicadores e Reagentes , Micro-Ondas , Dióxido de Silício/química , Solventes , Temperatura
15.
J Chromatogr A ; 987(1-2): 77-85, 2003 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-12613799

RESUMO

Polybutadiene (PBD) has been immobilized on HPLC silica by gamma radiation doses in the range from 5 to 180 kGy. Columns prepared from these reversed-phase materials, as well as from similar non-irradiated materials, were tested with standard sample mixtures and characterized by elemental analysis (% C) and infrared spectroscopy. A low dose of 5 kGy is sufficient to produce a layer of immobilized PBD which functions as an efficient and stable stationary phase. Higher doses give thicker immobilized layers having less favorable chromatographic properties.


Assuntos
Butadienos/química , Cromatografia Líquida de Alta Pressão/instrumentação , Polímeros/química , Elastômeros , Raios gama , Espectrofotometria Infravermelho
16.
J Chromatogr A ; 987(1-2): 87-92, 2003 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-12613800

RESUMO

The preparation of stationary phases for HPLC using polymers deposited on silica usually includes an immobilization step involving cross-linking by free radicals induced by ionizing radiation or by other radical initiators. The present paper reports changes which occur at ambient temperature in the character of poly(methyloctylsiloxane) deposited on porous silica particles as a function of the time interval between particle loading and column packing. Column performance and retention factors increase with time and these changes are attributed to rearrangement (self-assembly) which result in "self-immobilization" of the polymer molecules on the silica surface.


Assuntos
Cromatografia Líquida de Alta Pressão/instrumentação , Equipamentos e Provisões/normas
17.
J Chromatogr A ; 1030(1-2): 209-15, 2004 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-15043271

RESUMO

Silica supports having their surface modified with titanium oxide were prepared and coated with poly(methyloctylsiloxane) (PMOS). Subsequently, immobilization of the polysiloxane was induced by thermal treatment or microwave radiation. The thermal treatment was carried out for different times (4, 8, 16 and 24 h) at temperatures ranging between 100 and 220 degrees C. For PMOS immobilization by microwave radiation, 452, 520 and 586 W power levels and exposure times of 5, 15 and 30 min were used. After extraction of non-immobilized polymer, the chromatographic properties of the phases were evaluated. The phase immobilized at 120 degrees C for 8 h presented the best chromatographic parameters, suggesting that the quantity of acidic hydroxyl groups on the support surface was reduced, resulting in fewer undesirable interactions of a basic solute with the silanols not removed or covered on the support surface.


Assuntos
Cromatografia Líquida/instrumentação , Polímeros/química , Siloxanas/química , Titânio/química
18.
J Chromatogr A ; 1030(1-2): 225-9, 2004 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-15043273

RESUMO

Polybutadiene (PBD) has been immobilized on high-performance liquid chromatography (HPLC) silica by microwave radiation at various power levels (52-663 W) and actuation times (3-60 min). Columns prepared from these reversed-phase HPLC materials, as well as from similar non-irradiated materials, were tested with standard sample mixtures and characterized by elemental analysis (%C) and infrared spectroscopy. A microwave irradiation of 20 min at 663 W gives a layer of immobilized PBD that presented good performance. Longer irradiation times give thicker immobilized layers having less favorable chromatographic properties.


Assuntos
Butadienos/química , Cromatografia Líquida de Alta Pressão/instrumentação , Micro-Ondas , Polímeros/química , Elastômeros , Espectrofotometria Infravermelho
19.
J Chromatogr A ; 1030(1-2): 231-6, 2004 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-15043274

RESUMO

A 100 ml bottle of polybutadiene, PBD, was repeatedly exposed to air over a period of 6 months. Samples were taken at time zero (PBD-0), after 3 months (PBD-3) and 6 months (PBD-6). These samples were sorbed onto HPLC silica by an open-air solution-evaporation procedure, which involved exposure to the atmosphere for 6 days. Portions of the three sets of samples were used to compare self-immobilization and the effects of 100 degrees C thermal treatments in air or nitrogen on HPLC performance of the resulting phases. It is concluded that self-immobilization is enhanced by prior exposure of sorbed PBD to air and subsequent heating at 100 degrees C further enhances column performance. The best performance (10(5) plates m(-1)) resulted from 4 h heating of PBD-6 material in nitrogen.


Assuntos
Ar , Butadienos/química , Cromatografia em Gel/métodos , Cromatografia Líquida de Alta Pressão/métodos , Polímeros/química , Elastômeros
20.
J Chromatogr A ; 1030(1-2): 149-55, 2004 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-15043264

RESUMO

A procedure is presented for the rapid evaluation of HPLC stationary phase stability at pH 8.4 or 10.1 using a temperature of 60 degrees C. Mobile phase (MeOH-0.1 mol l(-1) aqueous NaHCO3, 50:50, v/v) is continuously passed through the column with periodic injections of a test solution until the several chromatographic parameters of the resulting chromatograms are degraded. The tests were applied to several commercial and laboratory-made stationary phases. After degradation two of these phases, one commercial and one laboratory-made, were examined by elemental analysis and scanning electron microscopy to elucidate the degradation process.


Assuntos
Cromatografia Líquida de Alta Pressão/instrumentação , Concentração de Íons de Hidrogênio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA