Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 81
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Cell ; 147(4): 773-88, 2011 Nov 11.
Artigo em Inglês | MEDLINE | ID: mdl-22078878

RESUMO

Although eukaryotic nuclei contain distinct architectural structures associated with noncoding RNAs (ncRNAs), their potential relationship to regulated transcriptional programs remains poorly understood. Here, we report that methylation/demethylation of Polycomb 2 protein (Pc2) controls relocation of growth-control genes between Polycomb bodies (PcGs) and interchromatin granules (ICGs) in response to growth signals. This movement is the consequence of binding of methylated and unmethylated Pc2 to the ncRNAs TUG1 and MALAT1/NEAT2, located in PcGs and ICGs, respectively. These ncRNAs mediate assembly of multiple corepressors/coactivators and can serve to switch mark recognition by "readers" of the histone code. Additionally, binding of NEAT2 to unmethylated Pc2 promotes E2F1 SUMOylation, leading to activation of the growth-control gene program. These observations delineate a molecular pathway linking the actions of subnuclear structure-specific ncRNAs and nonhistone protein methylation to relocation of transcription units in the three-dimensional space of the nucleus, thus achieving coordinated gene expression programs.


Assuntos
Núcleo Celular/metabolismo , Regulação da Expressão Gênica , RNA não Traduzido/metabolismo , Proteínas Repressoras/metabolismo , Sequência de Aminoácidos , Linhagem Celular , Cromatina/metabolismo , Fator de Transcrição E2F1/metabolismo , Células HeLa , Humanos , Ligases , Metilação , Metiltransferases/metabolismo , Dados de Sequência Molecular , Proteínas do Grupo Polycomb , RNA Longo não Codificante , Proteínas Repressoras/química , Sumoilação , Transcrição Gênica , Ubiquitina-Proteína Ligases , Ubiquitinação
2.
JAMA ; 331(6): 500-509, 2024 02 13.
Artigo em Inglês | MEDLINE | ID: mdl-38349372

RESUMO

Importance: The US heart allocation system prioritizes medically urgent candidates with a high risk of dying without transplant. The current therapy-based 6-status system is susceptible to manipulation and has limited rank ordering ability. Objective: To develop and validate a candidate risk score that incorporates current clinical, laboratory, and hemodynamic data. Design, Setting, and Participants: A registry-based observational study of adult heart transplant candidates (aged ≥18 years) from the US heart allocation system listed between January 1, 2019, and December 31, 2022, split by center into training (70%) and test (30%) datasets. Adult candidates were listed between January 1, 2019, and December 31, 2022. Main Outcomes and Measures: A US candidate risk score (US-CRS) model was developed by adding a predefined set of predictors to the current French Candidate Risk Score (French-CRS) model. Sensitivity analyses were performed, which included intra-aortic balloon pumps (IABP) and percutaneous ventricular assist devices (VAD) in the definition of short-term mechanical circulatory support (MCS) for the US-CRS. Performance of the US-CRS model, French-CRS model, and 6-status model in the test dataset was evaluated by time-dependent area under the receiver operating characteristic curve (AUC) for death without transplant within 6 weeks and overall survival concordance (c-index) with integrated AUC. Results: A total of 16 905 adult heart transplant candidates were listed (mean [SD] age, 53 [13] years; 73% male; 58% White); 796 patients (4.7%) died without a transplant. The final US-CRS contained time-varying short-term MCS (ventricular assist-extracorporeal membrane oxygenation or temporary surgical VAD), the log of bilirubin, estimated glomerular filtration rate, the log of B-type natriuretic peptide, albumin, sodium, and durable left ventricular assist device. In the test dataset, the AUC for death within 6 weeks of listing for the US-CRS model was 0.79 (95% CI, 0.75-0.83), for the French-CRS model was 0.72 (95% CI, 0.67-0.76), and 6-status model was 0.68 (95% CI, 0.62-0.73). Overall c-index for the US-CRS model was 0.76 (95% CI, 0.73-0.80), for the French-CRS model was 0.69 (95% CI, 0.65-0.73), and 6-status model was 0.67 (95% CI, 0.63-0.71). Classifying IABP and percutaneous VAD as short-term MCS reduced the effect size by 54%. Conclusions and Relevance: In this registry-based study of US heart transplant candidates, a continuous multivariable allocation score outperformed the 6-status system in rank ordering heart transplant candidates by medical urgency and may be useful for the medical urgency component of heart allocation.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Obtenção de Tecidos e Órgãos , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Bilirrubina , Serviços de Laboratório Clínico , Coração , Fatores de Risco , Medição de Risco , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/cirurgia , Estados Unidos , Alocação de Recursos para a Atenção à Saúde/métodos , Valor Preditivo dos Testes , Obtenção de Tecidos e Órgãos/métodos , Obtenção de Tecidos e Órgãos/organização & administração
3.
J Card Fail ; 29(11): 1543-1555, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37633442

RESUMO

The accurate assessment of hemodynamics is paramount to providing timely and efficacious care for patients presenting in cardiogenic shock. Recently, the regular use of the pulmonary artery catheter in cardiogenic shock has had a resurgence with emerging data indicating improved survival in the modern era. Optimal multidisciplinary management of advanced heart failure and cardiogenic shock relies on our ability to effectively communicate and understand the complete hemodynamic assessment. Standardization of data acquisition and a renewed focus on the physiological processes, and thresholds driving disease progression, including the coupling ratio and myocardial reserve, are needed to fully understand and interpret the hemodynamic assessment. This State-of-the-Art review discusses best practices in the cardiac catheterization laboratory as well as emerging data on the prognostic role of emerging advanced hemodynamic parameters.


Assuntos
Insuficiência Cardíaca , Humanos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Choque Cardiogênico , Hemodinâmica/fisiologia , Cateterismo Cardíaco , Padrões de Referência
4.
J Card Fail ; 29(11): 1507-1518, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37352965

RESUMO

BACKGROUND: Invasive hemodynamic measurement via right heart catheterization has shown divergent data in its role in the treatment of patients with heart failure (HF) and cardiogenic shock. We hypothesized that variation in data acquisition technique and interpretation might contribute to these observations. We sought to assess differences in hemodynamic acquisition and interpretation by operator subspecialty as well as level of experience. METHODS AND RESULTS: Individual-level responses to how physicians both collect and interpret hemodynamic data at the time of right heart catheterization was solicited via a survey distributed to international professional societies in HF and interventional cardiology. Data were stratified both by operator subspecialty (HF specialists or interventional cardiologists [IC]) and operator experience (early career [≤10 years from training] or late career [>10 years from training]) to determine variations in clinical practice. For the sensitivity analysis, we also look at differences in each subgroup. A total of 261 responses were received. There were 141 clinicians (52%) who self-identified as HF specialists, 99 (38%) identified as IC, and 20 (8%) identified as other. There were 142 early career providers (54%) and late career providers (119 [46%]). When recording hemodynamic values, there was considerable variation in practice patterns, regardless of subspecialty or level of experience for the majority of the intracardiac variables. There was no agreement or mild agreement among HF and IC as to when to record right atrial pressures or pulmonary capillary wedge pressures. HF cardiologists were more likely to routinely measure both Fick and thermodilution cardiac output compared with IC (51% vs 29%, P < .001), something mirrored in early career vs later career cardiologists. CONCLUSIONS: Significant variation exists between the acquisition and interpretation of right heart catheterization measurements between HF and IC, as well as those early and late in their careers. With the growth of the heart team approach to management of patients in cardiogenic shock, standardization of both assessment and management practices is needed.


Assuntos
Insuficiência Cardíaca , Choque Cardiogênico , Humanos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Hemodinâmica , Cateterismo Cardíaco/métodos , Débito Cardíaco
5.
Artif Organs ; 47(3): 574-581, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36305735

RESUMO

BACKGROUND: Invasive hemodynamic variables obtained from right heart catheterization have been used for risk-stratifying patients with advanced heart failure (HF). However, there is a paucity of data on the prognostic value of invasive hemodynamic variables in patients with left ventricular assist devices (LVAD). We hypothesized that cardiac power output (CPO), cardiac power efficiency (CPE), and left ventricular stroke work index (LVSWI) can serve as prognostic markers in patients with LVADs. METHODS: Baseline hemodynamic data from patients who had LVAD ramp studies at our institution from 4/2014 to 7/2018 were prospectively collected, from which advanced hemodynamic variables (CPO, CPE, and LVSWI) were retrospectively analyzed. Univariate and multivariable analyses were performed for hemocompatibility-related adverse events (HRAE), HF admissions, and mortality. RESULTS: Ninety-one participants (age 61 ± 11 years, 34% women, 40% Black or African American, and 38% ischemic cardiomyopathy) were analyzed. Low CPE was significantly associated with mortality (HR 2.42, 95% CI 1.02-5.74, p = 0.045) in univariate analysis and Kaplan-Meier analysis (p = 0.04). Low LVSWI was significantly associated with mortality (HR 2.13, 95% CI 1.09-4.17, p = 0.03) in univariate analysis and Kaplan-Meier analysis (p = 0.02). CPO was not associated with mortality. CPO, CPE, and LVSWI were not associated with HRAE or HF admissions. CONCLUSIONS: Advanced hemodynamic variables can serve as prognostic indicators for patients with LVADs. Low CPE and LVSWI are prognostic for higher mortality, but no variables were associated with HF admissions or HRAEs.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Prognóstico , Coração Auxiliar/efeitos adversos , Estudos Retrospectivos , Hemodinâmica , Débito Cardíaco
6.
J Card Fail ; 28(5): 845-862, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34980564

RESUMO

The HeartMate 3 left ventricular assist device (LVAD) is now the only centrifugal pump intended for durable support being actively manufactured and implanted for adults in the United States. The changes in preload and afterload that accompany common clinical scenarios experienced by patients with an LVAD will cause specific changes to the LVAD pump parameters, namely, the pump power, pulsatility index, and flow. Appropriate care of this unique, and growing, population requires a full understanding of these variables as well as the underlying physiologic principles governing their derivation. The aim of this review is to focus on the updated functionality of the HeartMate 3, specifically in comparison to the HeartMate II, as well as the application of pump parameter interpretation to common clinical scenarios.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Adulto , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/cirurgia , Humanos
7.
J Card Fail ; 28(5): 866-869, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34774746

RESUMO

BACKGROUND: The initial derivation of cardiac power output (CPO) included the difference between mean arterial pressure (MAP) and right atrial pressure (RAP) in the numerator, before multiplying by cardiac output (CO). We hypothesized that the inclusion of RAP (CPO-RAP) would enhance the prognostic performance of this parameter in those with an elevated RAP. METHODS AND RESULTS: We obtained patient-level data from the ESCAPE trial via the Biolincc database. Participants with full final hemodynamics were included in the analysis. The CPO-RAP was calculated as [(MAP - RAP) × CO)]/451 Watts (W), and the CPO was calculated as (MAP × CO)/451. The primary outcome was freedom from left ventricular assist device, heart transplant, or death at 6 months. Included participants (n = 157) were a median of 58 years of age (interquartile range [IQR] 49-67 years), 27% were women, and 59% had ischemic cardiomyopathy. The median CPO was 0.70 W (IQR 0.50-0.90 W), and the median CPO-RAP was 0.62 W (IQR 0.47-0.79 W). In univariable logistic regressions, the CPO was not associated with the primary outcome (odds ratio 0.32, 95% confidence interval 0.08-1.29, P = .11), but the CPO-RAP was (odds ratio 0.10, 95% confidence interval 0.02-0.54, P < .01). In Kaplan-Meier analyses, there were no significant difference in outcomes with CPO (76% vs 64%, P = .08), but for CPO-RAP, there were significant differences in outcomes (81% vs 63%, P = .01). When further delineating CPO-RAP by RAP above or below the median, there was no significant difference in the outcome for participants with a RAP 8 or less (94% vs 79%, P = .07), but a significant difference in participants with a RAP of more than 8 mm Hg (66% vs 45%, P < .05). CONCLUSIONS: The inclusion of RAP resulted in a significant association with the primary outcome; CPO alone was not.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Idoso , Pressão Atrial , Débito Cardíaco , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico
8.
Nature ; 534(7609): 700-4, 2016 06 30.
Artigo em Inglês | MEDLINE | ID: mdl-27357797

RESUMO

Many organs are composed of complex tissue walls that are structurally organized to optimize organ function. In particular, the ventricular myocardial wall of the heart comprises an outer compact layer that concentrically encircles the ridge-like inner trabecular layer. Although disruption in the morphogenesis of this myocardial wall can lead to various forms of congenital heart disease and non-compaction cardiomyopathies, it remains unclear how embryonic cardiomyocytes assemble to form ventricular wall layers of appropriate spatial dimensions and myocardial mass. Here we use advanced genetic and imaging tools in zebrafish to reveal an interplay between myocardial Notch and Erbb2 signalling that directs the spatial allocation of myocardial cells to their proper morphological positions in the ventricular wall. Although previous studies have shown that endocardial Notch signalling non-cell-autonomously promotes myocardial trabeculation through Erbb2 and bone morphogenetic protein (BMP) signalling, we discover that distinct ventricular cardiomyocyte clusters exhibit myocardial Notch activity that cell-autonomously inhibits Erbb2 signalling and prevents cardiomyocyte sprouting and trabeculation. Myocardial-specific Notch inactivation leads to ventricles of reduced size and increased wall thickness because of excessive trabeculae, whereas widespread myocardial Notch activity results in ventricles of increased size with a single-cell-thick wall but no trabeculae. Notably, this myocardial Notch signalling is activated non-cell-autonomously by neighbouring Erbb2-activated cardiomyocytes that sprout and form nascent trabeculae. Thus, these findings support an interactive cellular feedback process that guides the assembly of cardiomyocytes to morphologically create the ventricular myocardial wall and more broadly provide insight into the cellular dynamics of how diverse cell lineages organize to create form.


Assuntos
Ventrículos do Coração/citologia , Ventrículos do Coração/embriologia , Morfogênese , Miócitos Cardíacos/citologia , Peixe-Zebra/embriologia , Animais , Proteínas Morfogenéticas Ósseas/metabolismo , Proteínas de Ligação ao Cálcio/metabolismo , Linhagem da Célula , Retroalimentação Fisiológica , Ventrículos do Coração/anatomia & histologia , Proteína Jagged-2 , Miócitos Cardíacos/metabolismo , Tamanho do Órgão , Organogênese , Receptor ErbB-2/antagonistas & inibidores , Receptor ErbB-2/metabolismo , Receptores Notch/antagonistas & inibidores , Receptores Notch/metabolismo , Transdução de Sinais , Peixe-Zebra/genética , Peixe-Zebra/metabolismo , Proteínas de Peixe-Zebra/metabolismo
9.
Heart Vessels ; 37(12): 1995-2001, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35794489

RESUMO

OBJECTIVES: The purpose of this study is to investigate the early and late outcomes of axillary intra-aortic balloon pump (IABP) implantation as a bridge to heart transplantation, comparing the grafted technique with the percutaneous technique. METHODS: Between July 2009 and January 2020, 163 patients underwent an axillary IABP insertion as a bridge to heart transplantation. Among them, 97 patients underwent axillary IABP implantation through a graft sutured onto the axillary artery (Group A) and 66 patients underwent percutaneously (Group B). Propensity matching identified 53 matched pairs for analysis (C-statistics 0.741). The primary outcomes of interest included IABP-related complications, success rate of a bridge to transplantation, in-hospital mortality, and late survival. RESULTS: In the propensity-score matched cohort, there were no significant differences in the baseline characteristics between the two groups. The operation time was significantly longer in Group A than in Group B (141.5 ± 38.3 min vs 42.7 ± 19.3 min, p < 0.01). The complication rates including stroke, re-exploration for bleeding, and aortic event were not significantly different between Group A and B. However, Group A required more transfusion and re-exploration for bleeding. The success rate of a bridge to transplantation was similar between Group A (47/53, 88.7%) and Group B (47/53, 88.7%). There were no significant differences in in-hospital mortality and late survival between two groups. CONCLUSION: In the propensity score matching analysis, there were not any significant differences between the two groups in IABP-related complications, in-hospital mortality, and late survival. The percutaneous technique provided a shorter operation time and less requirement of transfusion and re-exploration for bleeding compared to the grafted technique. The percutaneous technique might be favorable when feasible.


Assuntos
Transplante de Coração , Coração Auxiliar , Humanos , Pontuação de Propensão , Estudos Retrospectivos , Balão Intra-Aórtico/efeitos adversos , Resultado do Tratamento
10.
Heart Vessels ; 37(4): 647-653, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34585275

RESUMO

We sought to assess the impact of the aortic root geometry on developing de novo aortic insufficiency (AI) in patients undergoing left ventricular assist device (LVAD). In total, 114 patients underwent LVAD implantation between February 2016 and January 2020 were included in this study (HeartMate3 N = 68, HeartWare N = 46). Significant aortic insufficiency was defined as mild-to-moderate or greater in echocardiography. The cohort was divided into two groups; those who developed significant AI (Group AI: n = 13) and did not (Group non-AI: n = 101). The primary outcomes of interest included late survival and predictors for significant AI. The patients in Group AI were older than Group non-AI (62.6 ± 11.9 vs 51.3 ± 14.0 years, p < 0.01). The diameter of proximal ascending aorta in Group AI was larger than Group non-AI (31.0 ± 5.0 vs 27.4 ± 4.3 mm, p < 0.01). Aortic valve remained closed in 53.8% in Group AI and 36.6% in Group non-AI (p = 0.24). The late survival was not significantly different between the groups (67.1% vs 76.0% at 3 years, log rank = 0.97). The Cox hazard model showed that larger proximal ascending aortic diameter/BSA (HR 1.55, CI 1.19-2.04, p < 0.01) and not-opening aortic valve (HR 4.73, CI 1.43-16.9, p = 0.01) were independent risk factors for significant AI. The cutoff value of proximal ascending aortic diameter/BSA was 15.5 (area under curve: 0.770, sensitivity: 0.69, specificity: 0.79). Dilated proximal ascending aorta at the time of LVAD surgery and not-opening aortic valve during follow-up were associated with the incidence of de novo significant AI.


Assuntos
Insuficiência da Valva Aórtica , Coração Auxiliar , Aorta/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico , Insuficiência da Valva Aórtica/epidemiologia , Insuficiência da Valva Aórtica/etiologia , Coração Auxiliar/efeitos adversos , Humanos , Incidência , Estudos Retrospectivos , Função Ventricular Esquerda
11.
Ann Vasc Surg ; 83: 42-52, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34995740

RESUMO

OBJECTIVE: Axillary Intra-aortic balloon pump (IABP) has been increasingly utilized for hemodynamic support in heart failure patients. Vascular complications associated with axillary IABP such as dissection or rupture are relatively rare but not negligible that could negatively affect clinical outcomes. We summarized our experiences. METHODS: This is a retrospective study reviewing of all patients receiving an axillary IABP between June 2016 and November 2020. A total of 199 patients underwent percutaneous axillary IABP placement. 6 patients (6/199, 3.0%) were complicated with arterial/aortic dissection or rupture during the procedures or the course of treatment. We described their clinical presentations and outcomes. RESULTS: Vascular complications included acute type A aortic dissection in 2 patients, descending aortic rupture in 1 patient, abdominal aortic rupture along with type B aortic dissection in 1 patient, and the localized left subclavian artery dissection in 2 patient. 2 type A aortic dissection cases were surgically treated: 1 with emergent left ventricle assist device and ascending aorta replacement, the other with emergent left ventricle assist device. Emergent endovascular treatment was successfully performed in 2 aortic rupture cases. The left subclavian artery dissection cases were managed medically. The postoperative/treatment course was uneventful in all patients. CONCLUSION: Percutaneous axillary IABP therapy can cause significant vascular complications. Early diagnosis and prompt treatment would be the key to improve the clinical outcomesv.


Assuntos
Dissecção Aórtica , Ruptura Aórtica , Coração Auxiliar , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Ruptura Aórtica/diagnóstico por imagem , Ruptura Aórtica/etiologia , Ruptura Aórtica/cirurgia , Coração Auxiliar/efeitos adversos , Humanos , Estudos Retrospectivos , Resultado do Tratamento
12.
Artif Organs ; 2022 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-36574590

RESUMO

PURPOSE: Tolvaptan, a selective vasopressin type-2 antagonist, has been shown to increase serum sodium (Na) and urine output in hyponatremic left ventricular assist device (LVAD) patients in retrospective studies. In this prospective randomized pilot study, we aimed to assess the efficacy of tolvaptan in this population. METHODS: We conducted a prospective, randomized, non-blinded pilot study of LVAD recipients with post-operative hyponatremia (Na < 135 mEq/L) (NCT05408104). Eligible participants were randomized to receive tolvaptan 15 mg daily in addition to usual care versus usual care alone. The primary outcome was a change in Na level and estimated glomerular filtration rate (eGFR), from the first post-operative day of hyponatremia (the day of randomization) to discharge. RESULTS: A total of 33 participants were enrolled, and 28 underwent randomization (median age 55 [IQR 50-62]), 21% women, 54% Black, 32% ischemic cardiomyopathy, median baseline Na 135 (IQR 134-138). Fifteen participants were randomized to tolvaptan (TLV) and 13 were randomized to usual care alone (No-TLV). Mean change in Na from randomization to discharge in the TLV group was 2.7 mEq/L (95%CI 0.7-4.7, p = 0.013) and 1.8 (95%CI 0.5-4.0, p = 0.11) in the No-TLV group, though baseline and final Na levels were similar between groups. The mean change in eGFR was 2.6 ml/min/1.73 m2 (95%CI 10.1-15.3, p = 0.59) in TLV versus 7.5 ml/min/1.73 m2 (95%CI 5.2-20.2, p = 0.15) in No-TLV. TLV participants had significantly more urine output than No-TLV patients during their first 24 h after randomization (3294 vs 2155 ml, p = 0.043). CONCLUSION: TLV significantly increases urine output, with nominal improvement in Na level, in hyponatremic post-operative LVAD patients without adversely impacting renal function.

13.
J Card Fail ; 27(10): 1045-1052, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34048919

RESUMO

BACKGROUND: Right heart catheterization for invasive hemodynamics has shown only modest correlation with clinical outcomes. We designed a novel hemodynamic variable that incorporates ventricular output and filling pressure. We anticipated that the aortic pulsatility index (API) would correlate with clinical outcomes in patients with heart failure. METHODS AND RESULTS: We retrospectively analyzed consecutive patients undergoing right heart catheterization with milrinone drug study at our institution (February 2013 to November 2019). The API was calculated as (systolic blood pressure - diastolic blood pressure)/pulmonary capillary wedge pressure. The primary outcome was freedom from advanced therapies, defined as the need for inotropes, temporary mechanical circulatory support, a left ventricular assist device, or orthotopic heart transplantation, or death at 30 days. A total of 224 patient encounters, age 57 years (48-66 years; 34% women; 31% ischemic cardiomyopathy) were included. In univariable analysis, lower baseline API was significantly associated with progression to advanced therapies or death at 30-days (odds ratio 0.43, 95% confidence interval 0.30-0.61; P < .001) compared with those on continued medical management. Receiver operator characteristic analysis specified an optimal cutpoint of 1.45 for API. A Kaplan-Meier analysis indicated an association of API with the primary outcome (79% for API ≥ 1.45 vs 48% for API < 1.45). In multivariable analysis, higher API was strongly associated with freedom from advanced therapies or death (odds ratio 0.38, 95% confidence interval 0.22-0.65, P ≤ .001), even when adjusted for baseline characteristics and routine right heart catheterization measurements. CONCLUSIONS: The API is a novel invasive hemodynamic measurement that is associated independently with freedom from advanced therapies or death at 30-day follow-up.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Pressão Propulsora Pulmonar , Estudos Retrospectivos
14.
Artif Organs ; 45(3): 297-302, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33098153

RESUMO

Aortic insufficiency remains a difficult to treat and highly morbid condition even in the era of HeartMate 3 left ventricular assist devices (LVADs). The prognostic nature of the longitudinal progression of aortic insufficiency, however, remains unknown. We prospectively collected data on patients who received HeartMate 3 LVAD implantation, who had assessments of aortic insufficiency using a novel Doppler echocardiography obtained at outflow graft at three (baseline) and 6 months postimplant. Patients with moderate or greater aortic insufficiency at baseline were excluded. The risk of aortic insufficiency progression on 1-year death and readmission for heart failure was investigated. In total, 41 patients (median 51 years old and 29 males) were included. All patients had less than moderate aortic insufficiency at baseline. Of them, 22 patients had worsening aortic insufficiency for 3 months following baseline assessments, which was associated with a significantly higher risk of 1-year death or heart failure readmission rate (41% vs. 11%, P = .023) with a hazard ratio of 3.24 (95% confidence interval 1.02-18.5, P = .038) adjusted for device speed at baseline and destination therapy indication. In patients with HeartMate 3 LVADs, progressive aortic insufficiency may be associated with a higher risk of 1-year death or readmission for heart failure. Close monitoring of patients with baseline aortic insufficiency should be considered as a measure to risk-stratify those for future adverse events.


Assuntos
Insuficiência da Valva Aórtica/diagnóstico , Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Complicações Pós-Operatórias/diagnóstico , Adulto , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/etiologia , Progressão da Doença , Ecocardiografia Doppler , Feminino , Seguimentos , Insuficiência Cardíaca/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Readmissão do Paciente/estatística & dados numéricos , Complicações Pós-Operatórias/etiologia , Modelos de Riscos Proporcionais , Estudos Prospectivos , Estudos Retrospectivos , Índices de Gravidade do Trauma , Resultado do Tratamento , Função Ventricular Esquerda/fisiologia
15.
J Artif Organs ; 24(4): 425-432, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33792816

RESUMO

Preoperative cardiopulmonary exercise testing (CPET) is well validated for prognostication before advanced surgical heart failure therapies, but its role in prognostication after LVAD surgery has never been studied. VE/VCO2 slope is an important component of CPET which has direct pathophysiologic links to right ventricular (RV) performance. We hypothesized that VE/VCO2 slope would prognosticate RV dysfunction after LVAD. All CPET studies from a single institution were collected between September 2009 and February 2019. Patients who ultimately underwent LVAD implantation were selectively analyzed. Peak VO2 and VE/VCO2 slope were measured for all patients. We evaluated their association with hemodynamic, echocardiographic and clinical markers of RV dysfunction as well mortality. Patients were stratified into those with a ventilatory class of III or greater. (VE/VCO2 slope of ≥ 36, n = 43) and those with a VE/VCO2 slope < 36 (n = 27). We compared the mortality between the 2 groups, as well as the hemodynamic, echocardiographic and clinical markers of RV dysfunction. 570 patients underwent CPET testing. 145 patients were ultimately referred to the advanced heart failure program and 70 patients later received LVAD implantation. Patients with VE/VCO2 slope of ≥ 36 had higher mortality (30.2% vs. 7.4%, p = 0.02) than patients with VE/VCO2 slope < 36 (n = 27). They also had a higher incidence of clinically important RVF (Acute severe 9.3% vs. 0%, Severe 32.6% vs 25.9%, p = 0.03). Patients with a VE/VCO2 slope ≥ 36 had a higher CVP than those with a lower VE/VCO2 slope (11.2 ± 6.1 vs. 6.0 ± 4.8 mmHg, p = 0.007), and were more likely to have a RA/PCWP ≥ 0.63 (65% vs. 19%, p = 0.008) and a PAPI ≤ 2 (57% vs. 13%, p = 0.008). In contrast, peak VO2 < 12 ml/kg/min was not associated with postoperative RV dysfunction or mortality. Elevated preoperative VE/VCO2 slope is a predictor of postoperative mortality, and is associated with postoperative clinical and hemodynamic markers of impaired RV performance.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Disfunção Ventricular Direita , Teste de Esforço , Insuficiência Cardíaca/diagnóstico , Humanos , Consumo de Oxigênio , Prognóstico
16.
BMC Med Inform Decis Mak ; 21(1): 106, 2021 03 20.
Artigo em Inglês | MEDLINE | ID: mdl-33743685

RESUMO

BACKGROUND: A central goal among researchers and policy makers seeking to implement clinical interventions is to identify key facilitators and barriers that contribute to implementation success. Despite calls from a number of scholars, empirical insights into the complex structural and cultural predictors of why decision aids (DAs) become routinely embedded in health care settings remains limited and highly variable across implementation contexts. METHODS: We examined associations between "reach", a widely used indicator (from the RE-AIM model) of implementation success, and multi-level site characteristics of nine LVAD clinics engaged over 18 months in implementation and dissemination of a decision aid for left ventricular assist device (LVAD) treatment. Based on data collected from nurse coordinators, we explored factors at the level of the organization (e.g. patient volume), patient population (e.g. health literacy; average sickness level), clinician characteristics (e.g. attitudes towards decision aid; readiness for change) and process (how the aid was administered). We generated descriptive statistics for each site and calculated zero-order correlations (Pearson's r) between all multi-level site variables including cumulative reach at 12 months and 18 months for all sites. We used principal components analysis (PCA) to examine any latent factors governing relationships between and among all site characteristics, including reach. RESULTS: We observed strongest inclines in reach of our decision aid across the first year, with uptake fluctuating over the second year. Average reach across sites was 63% (s.d. = 19.56) at 12 months and 66% (s.d. = 19.39) at 18 months. Our PCA revealed that site characteristics positively associated with reach on two distinct dimensions, including a first dimension reflecting greater organizational infrastructure and standardization (characteristic of larger, more established clinics) and a second dimension reflecting positive attitudinal orientations, specifically, openness and capacity to give and receive decision support among coordinators and patients. CONCLUSIONS: Successful implementation plans should incorporate specific efforts to promote supportive and mutually informative interactions between clinical staff members and to institute systematic and standardized protocols to enhance the availability, convenience and salience of intervention tool in routine practice. Further research is needed to understand whether "core predictors" of success vary across different intervention types.


Assuntos
Letramento em Saúde , Coração Auxiliar , Humanos , Motivação
17.
J Card Fail ; 26(4): 342-348, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31981696

RESUMO

BACKGROUND: HVAD left ventricular assist device flow waveforms provides graphical real-time information linking device performance with invasive hemodynamics. Previous studies have demonstrated a good correlation between the slopes of the ventricular filling phase slope (VFPS) and directly measured pulmonary capillary wedge pressure (PCWP). We aimed to validate the utility of VFPS to estimate PCWP and predict clinical outcomes. METHODS: In this prospective blinded study, screenshots from the HVAD monitor and simultaneous invasive hemodynamic measurements were obtained. Each screenshot was digitized and the VFPS was calculated by 2 independent reviewers who were blinded to the hemodynamic results. The equation PCWP = 7.053 +1.365 × (VFPS) was derived from a previously published dataset and the estimated PCWP was correlated to the actually measured PCWP. RESULTS: One hundred thirty-one sets of simultaneous measurements (VFPS and PCWP) were obtained from 27 HVAD patients (mean age 55 years, 47% male). A previously proposed cutoff of VFPS ≥5.8 L/min/s predicted PCWP ≥ 18 mmHg with 91.5% sensitivity and 95.2% specificity with the area under curve of 0.987. The estimated PCWP significantly correlated with measured PCWP (R2 = 0.65, P < .001) and showed acceptable agreement with measured PCWP. Patients with VFPS ≥ 5.8 L/min/s experienced significantly higher heart failure readmission rates than those without (0.24 vs 0.05 events/y, P < .001). CONCLUSIONS: VFPS of the HVAD flow waveform is a novel noninvasive parameter that can estimate PCWP.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Feminino , Insuficiência Cardíaca/diagnóstico , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Pressão Propulsora Pulmonar
18.
J Card Fail ; 26(10): 863-869, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32473380

RESUMO

BACKGROUND: Aortic insufficiency (AI) is associated with morbidity and mortality in patients with continuous-flow left ventricular assist devices (LVADs), whereas its impact on the HeartMate 3 LVAD cohorts remains uninvestigated. We aimed to investigate the clinical impact of AI on patients with HeartMate 3 LVADs. METHODS AND RESULTS: Consecutive 61 patients (median age 54 years; 67% male) implanted with HeartMate 3 LVAD between 2015 and 2019 were enrolled and underwent echocardiography at 3 months after LVAD implantation. AI severity was quantified by the novel Doppler echocardiographic method obtained at the outflow cannula and the calculated regurgitation fraction of 30% or greater (moderate or greater) was defined as significant. At 3 months after implant, 12 patients (20%) had significant AI. They had a higher incidence of death or heart failure readmissions compared with those without significant AI during a 1-year observational period (70% vs 24%, P = .003) with an adjusted hazard ratio of 2.76 (95% confidence interval 1.03-7.88). CONCLUSIONS: In patients with HeartMate 3 LVAD support, significant AI remains both prevalent and a clinically significant downstream complication.


Assuntos
Insuficiência da Valva Aórtica , Insuficiência Cardíaca , Coração Auxiliar , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/epidemiologia , Insuficiência da Valva Aórtica/etiologia , Pré-Escolar , Ecocardiografia , Ecocardiografia Doppler , Feminino , Insuficiência Cardíaca/terapia , Coração Auxiliar/efeitos adversos , Humanos , Masculino , Estudos Retrospectivos
20.
J Card Fail ; 25(10): 787-794, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31419485

RESUMO

AIM: Hemocompatibility-related adverse events (HRAE) are a major cause of readmissions in patients with left ventricular assist devices (LVAD). The impact of aortic insufficiency (AI) on HRAE remains uncertain. We aimed to investigate the impact of AI on HRAE. METHODS AND RESULTS: Patients who underwent LVAD implantation between August 2014 and July 2017 and had echocardiograms 3 months post-LVAD implantation were enrolled. AI severity was assessed by measuring the systolic/diastolic ratio of flow and the rate of diastolic flow acceleration using Doppler echocardiography of the outflow cannula. Regurgitation fraction was derived from these parameters. Significant AI was defined as regurgitation fraction > 30%. Among 105 patients (median age, 56 years; 76% male), 36 patients (34%) had significant AI. Baseline characteristics were statistically not significantly different between those with and without significant AI except for higher rates of ischemic etiology and atrial fibrillation in the significant AI group (P < 0.05 for both). One-year survival free from HRAE was 44% in patients with AI compared to 67% in patients without significant AI (P = 0.018). The average hemocompatibility score, which defines the net burden of HRAE, was higher in the AI group (1.72 vs 0.64; P = 0.009), due mostly to higher tier I (mild HRAE; P = 0.034) and tier IIIB scores (severe HRAE; P = 0.011). CONCLUSION: Significant AI, as assessed by Doppler echocardiographic parameters, was associated with HRAE during LVAD support.


Assuntos
Insuficiência da Valva Aórtica , Insuficiência Cardíaca , Coração Auxiliar/efeitos adversos , Insuficiência da Valva Aórtica/complicações , Insuficiência da Valva Aórtica/diagnóstico , Insuficiência da Valva Aórtica/fisiopatologia , Ecocardiografia Doppler/métodos , Feminino , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/cirurgia , Monitorização Hemodinâmica/métodos , Humanos , Masculino , Teste de Materiais/métodos , Pessoa de Meia-Idade , Estudos Retrospectivos , Índice de Gravidade de Doença , Estados Unidos , Função Ventricular Esquerda
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA