Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 253
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Surg Endosc ; 35(3): 1052-1057, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32095953

RESUMO

BACKGROUND: An intragastric satiety-inducing device (ISD) (Full Sense Device; Baker, Foote, Kemmeter, Walburn, LLC, Grand Rapids, MI) is a novel weight-loss device, which may induce satiety by applying continuous pressure on the gastric cardia. This study investigated the effect of the ISD on food intake and body weight gain in a rodent model. METHODS: Thirty-two male Sprague-Dawley rats (weight, 250-300 g) were randomly divided into four groups of eight individuals. Single-disk (SD) and double-disk (DD) group animals underwent peroral placement of a single- or double-disk ISD, respectively, under fluoroscopic guidance. The ISD comprised a 4 mm × 1.5 cm nitinol stent placed in the lower esophagus and one (single-disk) or two (double-disk) 2.5-cm-diameter star-shaped nitinol disks placed in the gastric fundus. Esophageal stent (ES) and sham-operated (SO) group animals underwent peroral placement of the ES part of the ISD and a sham operation, respectively. RESULTS: Food intake was significantly different among the four groups over the 4-week study period (P < 0.001); food intake was significantly lower in the SD and DD groups than in the SO group (P = 0.016 and P = 0.002, respectively) but was not significantly different between the SD and DD groups (P > 0.999) and between the ES and SO groups (P = 0.677). Body weight was significantly different among the four groups by the end of the study period (P < 0.001); body weight was significantly lower in the DD group than in the SD, ES, and SO groups (P = 0.010, P < 0.001, and P < 0.001, respectively) and in the SD group than in the SO group (P = 0.001), but it was not significantly different between the ES and SO groups (P = 0.344). CONCLUSION: ISD reduced food intake and suppressed body weight gain in a rodent model.


Assuntos
Ingestão de Alimentos , Fisiologia/instrumentação , Saciação , Estômago/fisiologia , Aumento de Peso/fisiologia , Animais , Jejum/sangue , Grelina/sangue , Masculino , Modelos Animais , Ratos Sprague-Dawley , Roedores
2.
J Vasc Interv Radiol ; 30(10): 1562-1566, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31409566

RESUMO

PURPOSE: To prospectively evaluate the midterm outcomes of fluoroscopic eustachian tube (E-tube) balloon dilation by using a flexible guide wire in patients with obstructive E-tube dysfunction. MATERIALS AND METHODS: From October 2016 to September 2017, adult outpatients with persistent otitis media who were unable to perform the Valsalva maneuver were prospectively enrolled. The analysis included 32 E-tubes from 31 patients (18 women, 13 men; mean age, 47 years old, range 25-72 years). Participants underwent fluoroscopic E-tube balloon dilation with a 0.035-inch flexible guide wire and a 6- × 20-mm balloon catheter. Clinical examinations to check for the ability to perform the Valsalva maneuver and otomicroscopy were conducted at 1 week and then at 1, 3, 12, and 18 months after the procedure. RESULTS: Balloon dilation was technically successful in all E-tubes. The mean time required for the procedure was 6.9 minutes (range, 5.8-10.3 minutes). The Valsalva maneuver was successful in opening 25 of 32 E-tubes (78.1%) at 3 months after balloon dilation. During the median follow-up of 15.9 months, failure of the Valsalva maneuver occurred in 4 of 25 improved E-tubes (16%), yielding a 2-year patency rate of 84%. CONCLUSIONS: The fluoroscopic balloon dilation results were encouraging, and using a flexible guide wire for E-tube balloon dilation did not cause a false passage.


Assuntos
Cateterismo/instrumentação , Catéteres , Otopatias/terapia , Tuba Auditiva/fisiopatologia , Radiografia Intervencionista , Adulto , Idoso , Cateterismo/efeitos adversos , Dilatação , Otopatias/diagnóstico por imagem , Otopatias/fisiopatologia , Desenho de Equipamento , Tuba Auditiva/diagnóstico por imagem , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Tempo , Resultado do Tratamento
3.
Biochem Biophys Res Commun ; 500(3): 783-789, 2018 06 07.
Artigo em Inglês | MEDLINE | ID: mdl-29684347

RESUMO

Postoperative peritoneal adhesions, fibrous bands formed in the peritoneal cavity following surgery, represent a common, challenging and costly problem faced by surgeons and patients, for which effective therapeutic options are lacking. Since aberrant inflammation is one of the key mechanisms underlying peritoneal adhesion formation, here we set out to study the role of developmental endothelial locus-1 (Del-1), which has been recently identified as an endogenous inhibitor of inflammation, in the formation of postoperative peritoneal adhesions using a mouse model of peritoneal adhesions induced by ischemic buttons. Del-1-deficient mice had a higher incidence of adhesions, and their adhesions had higher quality and tenacity scores. Del-1 deficiency also led to enhanced inflammation mediators and collagen production. Finally, Del-1 supplementation decreased the incidence and severity of postoperative peritoneal adhesions. Taken together, these results indicate a protective role for Del-1 in postoperative peritoneal adhesion formation.


Assuntos
Proteínas de Transporte/metabolismo , Doenças Peritoneais/metabolismo , Doenças Peritoneais/prevenção & controle , Peritônio/patologia , Aderências Teciduais/metabolismo , Aderências Teciduais/prevenção & controle , Animais , Proteínas de Ligação ao Cálcio , Moléculas de Adesão Celular , Matriz Extracelular/metabolismo , Proteínas da Matriz Extracelular/metabolismo , Inflamação/patologia , Peptídeos e Proteínas de Sinalização Intercelular , Masculino , Camundongos Endogâmicos C57BL , Inibidor 1 de Ativador de Plasminogênio/metabolismo , Complicações Pós-Operatórias/etiologia , Receptores Fc/metabolismo , Índice de Gravidade de Doença , Aderências Teciduais/etiologia
4.
Radiology ; 286(1): 140-148, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28787263

RESUMO

Purpose To investigate the use of sirolimus-eluting biodegradable stents (SEBSs) to suppress granulation tissue formation after stent placement in a rat urethral model. Materials and Methods All experiments were approved by the animal research committee. A total of 36 male Sprague-Dawley rats were randomized into three equal groups after biodegradable stent placement. Group A received control biodegradable stents. Groups B and C received stents coated with 90 µg/cm2 and 450 µg/cm2 sirolimus, respectively. Six rats in each group were sacrificed after 4 weeks; the remaining rats were sacrificed after 12 weeks. The therapeutic effectiveness of SEBSs was assessed by comparing the results of retrograde urethrography and histologic examination. Analysis of variance with post hoc comparisons was used to evaluate statistical differences. Results SEBS placement was technically successful in all rats. Urethrographic and histologic examinations revealed significantly less granulation tissue formation at both time points in the rats receiving SEBSs (groups B and C) compared with those that received control stents (group A) (P < .05 for all). There were no significant differences in urethrographic and histologic findings between groups B and C (P > .05 for all). However, the mean number of epithelial layers in group B was higher than that in group C at 4 weeks after stent placement (P < .001). Apoptosis increased in group C compared with groups A and B (P < .05 for all). Conclusion The use of SEBSs suppressed granulation tissue formation secondary to stent placement in a rat urethral model; local therapy with SEBSs may be used to decrease stent-related granulation tissue formation. © RSNA, 2017.


Assuntos
Stents Farmacológicos , Poliésteres/farmacologia , Sirolimo/farmacologia , Uretra/efeitos dos fármacos , Animais , Antibióticos Antineoplásicos/farmacologia , Masculino , Ratos , Ratos Sprague-Dawley , Uretra/citologia , Uretra/patologia
5.
Eur Radiol ; 28(3): 910-919, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28956124

RESUMO

OBJECTIVES: To prospectively evaluate the technical feasibility and safety of fluoroscopy-guided balloon dilation in patients with Eustachian tube (ET) dysfunction. METHODS: Patients who could not do a Valsalva manoeuvre for more than 6 months and diagnosed with chronic otitis media or ET dysfunction were prospectively enrolled. A 0.035-in. guide wire and 6-mm long balloon catheter with a diameter of 2 mm were used to dilate the cartilaginous portion of the ET under fluoroscopic guidance. The balloon was inflated by manual injection twice for 1 min each time. Clinical outcomes were assessed by the patient's ability to perform a Valsalva manoeuvre, and symptoms were assessed using the 7-item Eustachian Tube Dysfunction Questionnaire (ETDQ-7) score. RESULTS: Balloon dilation was attempted in a total of ten adult patients from October 2016 to March 2017. Technical success was achieved in all procedures (10/10). Ninety percent (9/10) of the balloons were fully dilated without waist deformity. There were no major complications. All patients were able to perform a Valsalva manoeuvre at the time of their last visit and/or improvement of at least one ETDQ-7 score. CONCLUSION: Fluoroscopy-guided balloon dilation seems to be technically feasible and safe in the treatment of ET dysfunction. KEY POINTS: • Fluoroscopy-guided balloon dilation without general anaesthesia was well-tolerated in all patients. • Location of the balloon catheter can be monitored during the procedure. • Inflation state of the balloon catheter can be monitored during the procedure. • Using guide-wire during the procedure would prevent false passage creation. • All patients had clinical improvement within 3 months after balloon dilation.


Assuntos
Dilatação/métodos , Endoscopia/métodos , Tuba Auditiva , Fluoroscopia/métodos , Otite Média/terapia , Adulto , Idoso , Doença Crônica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Otite Média/diagnóstico , Inquéritos e Questionários , Resultado do Tratamento
6.
Eur Radiol ; 28(9): 3685-3691, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29619519

RESUMO

OBJECTIVES: To evaluate the technical feasibility of direct Eustachian tube catheterisation and subtraction Eustachian tubography in a cadaver model. METHODS: A total of 12 separate sessions were performed on both sides of the Eustachian tube (ET) in six human cadavers. Cadavers were positioned for the submentovertical view on a fluoroscopy table. Endoscopy-guided ET selection was used in the first three cadavers, whereas fluoroscopy-guided ET selection was used in the remaining three. Eustachian tubography was performed by injecting 2 ml of contrast media through a 5-Fr catheter. We recorded the success of ET selection, number of attempts, procedure time, and tubography quality using native and subtraction images (range, 0-3). RESULTS: Both endoscopy- and fluoroscopy-guided selections were successfully performed in five of six sessions (83.3%). There were no statistically significant differences between the endoscopy- and fluoroscopy-guided procedures in terms of the number of attempts, procedure time, rate of immediate contrast leak to the middle ear cavity, and quality of tubography (p > 0.05). An excellent quality of tubography was obtained in 83.3% (10 of 12 sessions) of subtraction images and in 33.3% (4 of 12 sessions) of native images. The tubography quality score was significantly higher for the subtraction images than for the native images (p = 0.04). CONCLUSION: Subtraction Eustachian tubography using direct catheterisation seems to be technically feasible. The entire ET can be well visualised; thus, this technique can be used as a simple tool for assessment of ET function and anatomy. KEY POINTS: • Direct catheterisation of the Eustachian tube is technically feasible. • The entire Eustachian tube could be well visualised by direct Eustachian tubography. • Subtraction Eustachian tubography images have better image quality than native images. • Subtraction Eustachian tubography can provide objective assessment of ET function and anatomy.


Assuntos
Cateterismo/métodos , Endoscopia/métodos , Tuba Auditiva/diagnóstico por imagem , Cadáver , Meios de Contraste , Estudos de Viabilidade , Feminino , Fluoroscopia/métodos , Humanos , Masculino , Intensificação de Imagem Radiográfica
7.
J Vasc Interv Radiol ; 29(3): 320-327, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-28917485

RESUMO

PURPOSE: To identify predictors associated with clinical outcomes (initial clinical failure, stent patency, and survival) after self-expandable metal stent (SEMS) placement for malignant esophagorespiratory fistulas (ERFs). MATERIALS AND METHODS: Using logistic and Cox regression analyses, this study reviewed 88 patients (mean age 59.4 y ± 8.4; 84 men [95.5%] and 4 women [4.5%]) who underwent fluoroscopic SEMS placement for palliating malignant ERF from January 2000 to December 2016. RESULTS: Technical success was achieved in all patients. Initial clinical success was achieved in 78.4% (69/88; 95% confidence interval [CI], 68.7%-85.7%). Among the 69 patients in whom initial clinical success was achieved, aspiration symptoms recurred in 37.7% (26/69; 95% CI, 27.2%-49.5%). Overall major complication rate was 25.0% (22/88; 95% CI, 17.1%-35.0%). Cumulative stent patency and cumulative survival rates at 1, 3, 6, and 12 months were 72.8%, 38.9%, 32.4%, and 21.6% and 81.4%, 51.9%, 30.5%, and 13.3%, respectively. Stricture of the upper esophagus was an independent predictor of initial clinical failure (odds ratio, 3.760; 95% CI, 1.207-11.811) and shorter stent patency (hazard ratio [HR], 2.036; 95% CI, 1.170-3.544). Initial clinical failure was an independent predictor of shorter survival (HR, 2.902; 95% CI, 1.587-5.305). CONCLUSIONS: SEMS placement offers sufficient short-term relief despite considerable major complications. Stricture of the upper esophagus is an independent predictor of initial clinical failure and shorter stent patency. Initial clinical failure is an independent predictor of shorter survival.


Assuntos
Fístula Esofágica/terapia , Neoplasias Esofágicas/terapia , Neoplasias Pulmonares/terapia , Cuidados Paliativos/métodos , Fístula do Sistema Respiratório/terapia , Stents Metálicos Autoexpansíveis , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Estudos Retrospectivos , Taxa de Sobrevida , Resultado do Tratamento
8.
J Vasc Interv Radiol ; 29(12): 1756-1763, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30266211

RESUMO

PURPOSE: To evaluate the feasibility of self-expanding metal stent (SEMS) placement and fluorescence microendoscopic monitoring for determination of fibroblast cell proliferation after stent placement in an esophageal mouse model. MATERIALS AND METHODS: Twenty fibroblast-specific protein (FSP)-1 green fluorescent protein (GFP) transgenic mice were analyzed. Ten mice (Group A) underwent SEMS placement, and fluoroscopic and fluorescence microendoscopic images were obtained biweekly until 8 weeks thereafter. Ten healthy mice (Group B) were used for control esophageal values. RESULTS: SEMS placement was technically successful in all mice. The relative average number of fibroblast GFP cells and the intensities of GFP signals in Group A were significantly higher than in Group B after stent placement. The proliferative cellular response, including granulation tissue, epithelial layer, submucosal fibrosis, and connective tissue, was increased in Group A. FSP-1-positive cells were more prominent in Group A than in Group B. CONCLUSIONS: SEMS placement was feasible and safe in an esophageal mouse model, and proliferative cellular response caused by fibroblast cell proliferation after stent placement was longitudinally monitored using a noninvasive fluorescence microendoscopic technique. The results have implications for the understanding of proliferative cellular response after stent placement in real-life patients and provide initial insights into new clinical therapeutic strategies for restenosis.


Assuntos
Proliferação de Células , Esofagoscopia/instrumentação , Esôfago/patologia , Fibroblastos/patologia , Microscopia de Fluorescência , Stents Metálicos Autoexpansíveis , Animais , Esofagoscopia/efeitos adversos , Esôfago/metabolismo , Estudos de Viabilidade , Fibroblastos/metabolismo , Genes Reporter , Proteínas de Fluorescência Verde/genética , Proteínas de Fluorescência Verde/metabolismo , Teste de Materiais , Camundongos Transgênicos , Desenho de Prótese , Proteína A4 de Ligação a Cálcio da Família S100/genética , Proteína A4 de Ligação a Cálcio da Família S100/metabolismo , Fatores de Tempo
9.
J Vasc Interv Radiol ; 29(8): 1187-1193, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-30056936

RESUMO

PURPOSE: To investigate the technical feasibility of stent placement in the cartilaginous portion of the Eustachian tube (ET). MATERIALS AND METHODS: Twelve ETs of 6 cadavers were used. Two different-sized stents were placed on either the right (2.5 mm in diameter) or left (3.5 mm in diameter) side of the ET. The procedural feasibility was assessed by subtraction Eustachian tubography, computed tomography before and after the procedure, and fluoroscopic and endoscopic images. The stent location, inner luminal diameter of the stented ET, radiation dose, procedural time, and fluoroscopy time were analyzed. RESULTS: Stent placement was successful in 11 of 12 cadaveric specimens without procedure-related complications. In the 1 specimen, the balloon catheter with crimped stent was passed into the bony canal of the ET without any resistance. The distal end of the stent was located in the middle ear cavity. Stents were located within the cartilaginous portion of the ET (n = 1), the proximal tip bridging the nasopharyngeal orifice of the ET (n = 5), or the proximal end of the stent protruded from the tubal orifice (n = 5). The mean luminal diameter in the outer segment was significantly smaller than in the middle (P < .001) and inner (P < .001) segments. The mean procedure time was 128 ± 37 seconds. The mean radiation dose and fluoroscopy time of each cadaver were 3235.4 ± 864.8 cGy/cm2 and 139 ± 49 seconds, respectively. CONCLUSIONS: Stent placement of the ET under endoscopic and fluoroscopic guidance is technically feasible in a human cadaver model.


Assuntos
Cateterismo/instrumentação , Ligas de Cromo , Dilatação/instrumentação , Endoscopia/métodos , Tuba Auditiva , Radiografia Intervencionista/métodos , Stents , Cadáver , Tuba Auditiva/diagnóstico por imagem , Estudos de Viabilidade , Fluoroscopia , Humanos , Desenho de Prótese , Doses de Radiação , Tomografia Computadorizada por Raios X
10.
Acta Radiol ; 59(3): 313-321, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28573925

RESUMO

Background Balloon dilation is safe and effective for the treatment of radiation-induced esophageal stricture (RIES), with favorable short-term and mid-term outcomes; however, few reports of long-term outcomes exist. Few studies have evaluated factors associated with recurrence after balloon dilation. Purpose To evaluate the long-term outcome of balloon dilation in patients with RIES and to identify factors associated with stricture recurrence. Material and Methods The medical records of 62 consecutive patients who had undergone fluoroscopic balloon dilation for RIES at our institution between December 1998 and June 2016 were reviewed. Results One hundred and twenty balloon dilation sessions were performed in 62 patients (mean = 1.9 sessions per patient). Clinical success was achieved in 53 (86%) patients after single (n = 37) or multiple (n = 16) dilation sessions. Complications occurred in 27% of the dilation sessions. The primary patency rates at one, two, three, and five years were 60%, 56%, 52%, and 52%, respectively. Secondary patency rates at one, two, three, and five years were 87%, 85%, 85%, and 80%, respectively. Multivariate logistic regression analysis identified an interval from radiation therapy (RT) to stricture of ≥6 months (hazard ratio [HR] = 0.205; P < 0.001), strictures located at the cervical esophagus (HR = 5.846; P < 0.001), and stricture length of ≥2 cm (HR = 2.923; P = 0.006) as significant predictors of recurrence. Conclusion Despite the high incidence of ruptures and recurrences, fluoroscopic balloon dilation is valuable as an initial therapeutic option for patients with RIES.


Assuntos
Dilatação/métodos , Estenose Esofágica/terapia , Lesões por Radiação/terapia , Radiografia Intervencionista/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Estenose Esofágica/etiologia , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Lesões por Radiação/complicações , Recidiva , Estudos Retrospectivos , Resultado do Tratamento
11.
Clin Otolaryngol ; 43(6): 1573-1577, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30160368

RESUMO

OBJECTIVES: To measure the diameter of inflated balloons at different pressures during Eustachian tube (ET) balloon dilation under fluoroscopic guidance. DESIGN: Prospective cohort study. SETTING: Tertiary academic referral centre. PARTICIPANTS: Eighteen patients who underwent ET balloon dilation with use of a balloon catheter, 20 mm long and 6 mm in diameter, under combined endoscopic and fluoroscopic guidance. MAIN OUTCOME MEASURES: Degrees of inflation at three different portions (proximal, middle and distal) of the balloon at controlled pressures (3, 5, 8 and 10 atmospheres [atm]) and at the maximum pressure manually applied. RESULTS: The mean proximal, middle and distal diameters of the inflated balloons were 5.3 ± 0.4 mm, 5.3 ± 0.4 mm and 4.9 ± 0.5 mm at 10 atm. The distal diameters were significantly smaller than middle and proximal diameters at all the pressures (P < 0.01). When compared to the distal diameter (100%, 4.9 ± 0.5 mm) at 10 atm, the distal diameters were 73% (3.6 ± 0.6 mm) at 3 atm, 88% (4.3 ± 0.5 mm) at 5 atm and 96% (4.7 ± 0.4 mm) at 8 atm. The distal diameter (4.1 ± 0.3 mm) at the maximum pressure manually applied was in between those at 3 and 5 atm. CONCLUSIONS: The distal diameter of the balloon increased significantly as a function of the pressure and most (88%) inflation occurred at a low pressure of 5 atm, which was sufficient to inflate the distal diameter of the balloon more than 3 mm. The manual pressurisation could inflate a balloon by as much as could be expected, at between 3 and 5 atm.


Assuntos
Cateterismo/instrumentação , Dilatação/instrumentação , Endoscopia/métodos , Tuba Auditiva/diagnóstico por imagem , Fluoroscopia/métodos , Otite Média com Derrame/diagnóstico , Adulto , Idoso , Doença Crônica , Desenho de Equipamento , Tuba Auditiva/fisiopatologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Otite Média com Derrame/terapia , Pressão , Estudos Prospectivos , Tomografia Computadorizada por Raios X
12.
Gastrointest Endosc ; 86(1): 219-228, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28137596

RESUMO

BACKGROUND AND AIMS: Self-expanding metallic stent (SEMS) placement is a well-established method for treating malignant esophageal strictures; however, this procedure has not gained widespread acceptance for treating benign esophageal strictures because of granulation tissue formation. The aim of the present study was to investigate whether EW-7197, a novel per-oral transforming growth factor-ß type I receptor kinase inhibitor, suppressed granulation tissue formation after SEMS placement in the rat esophagus. METHODS: Sixty rats underwent SEMS placement and were randomly divided into 4 groups. Group A (n = 20) received vehicle-treated control for 4 weeks. Group B (n = 20) received 20 mg/kg/day EW-7197 for 4 weeks. Group C (n = 10) received 20 mg/kg/day EW-7197 for 4 weeks followed by vehicle-treated control for 4 weeks. Group D (n = 10) received 20 mg/kg/day EW-7197 for 8 weeks. RESULTS: SEMS placement was technically successful in all rats. Eleven rats, however, were excluded because of stent migration (n = 9) and procedure-related death (n = 2). The luminal diameter in group A was significantly smaller than those in groups B, C, and D (all P < .001). The percentage of granulation tissue area, number of epithelial layers, thickness of submucosal fibrosis, percentage of connective tissue area, and degree of collagen deposition were significantly higher in group A than in groups B, C, and D (all P < .001); however, there were no significant differences among groups B, C, and D. EW-7197 decreased the expression levels of phospho-Smad 3, N-cadherin, fibronectin, α-smooth muscle actin, and transforming growth factor-ß1 and increased the expression level of E-cadherin (all P < .01). CONCLUSIONS: EW-7197 suppressed granulation tissue formation after SEMS placement in the rat esophagus.


Assuntos
Compostos de Anilina/farmacologia , Esôfago/efeitos dos fármacos , Tecido de Granulação/efeitos dos fármacos , Tecido de Granulação/patologia , Inibidores de Proteínas Quinases/farmacologia , Stents Metálicos Autoexpansíveis/efeitos adversos , Triazóis/farmacologia , Actinas/metabolismo , Animais , Caderinas/metabolismo , Esôfago/diagnóstico por imagem , Esôfago/metabolismo , Esôfago/patologia , Fibronectinas/metabolismo , Tecido de Granulação/diagnóstico por imagem , Tecido de Granulação/metabolismo , Masculino , Proteínas do Tecido Nervoso/metabolismo , Fosforilação , Proteínas Serina-Treonina Quinases/antagonistas & inibidores , Radiografia , Ratos , Ratos Sprague-Dawley , Receptor do Fator de Crescimento Transformador beta Tipo I , Receptores de Fatores de Crescimento Transformadores beta/antagonistas & inibidores , Proteína Smad3/metabolismo , Fator de Crescimento Transformador beta1/metabolismo
13.
Eur Radiol ; 27(1): 105-112, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27048529

RESUMO

OBJECTIVES: The purpose of this study is to investigate the incidence and management of oesophageal ruptures following fluoroscopic balloon dilatation (FBD) in children with benign oesophageal strictures. METHODS: Sixty-two children with benign oesophageal strictures underwent FBDs. Oesophageal rupture was categorized as intramural (type 1), transmural (type 2), or transmural with free leakage (type 3). The possible risk factors for oesophageal ruptures were analyzed. RESULTS: One hundred and twenty-nine FBDs were performed in these patients. The oesophageal rupture rate was 17.1 % (22/129). The majority (21/22) of ruptures were type 1 and type 2, both were treated conservatively. Only one patient had a type 3 rupture and underwent oesophagoesophagostomy. The patient gender, age, and the length and cause of the stricture showed no significant effect on the rupture (P > 0.05). However, for the patients ≤2 years old, the initial balloon with a diameter ≥10 mm showed a higher oesophageal rupture rate than those <10 mm during the first session (P = 0.03). CONCLUSIONS: Although the oesophageal rupture rate in children was 17.1 %, the type 3 rupture rate was 0.8 %, which usually requires aggressive treatment. For children ≤2 years old, the initial balloon diameter should be <10 mm in the first session for decreasing the risk of oesophageal rupture. KEY POINTS: • The oesophageal rupture rate following balloon dilatation in children was 17.1 %. • The incidence of transmural rupture with free leakage is very low. • Only transmural rupture with free leakage needs aggressive treatment. • For children ≤2 years, the initial balloon diameter should be <10 mm.


Assuntos
Cateterismo/efeitos adversos , Dilatação/efeitos adversos , Estenose Esofágica/terapia , Esôfago/lesões , Fluoroscopia , Adolescente , Criança , Pré-Escolar , Estenose Esofágica/diagnóstico , Esôfago/diagnóstico por imagem , Feminino , Humanos , Incidência , Lactente , Recém-Nascido , Masculino , Fatores de Risco , Ruptura , Resultado do Tratamento
14.
Eur Radiol ; 27(3): 1257-1266, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27329523

RESUMO

OBJECTIVES: To evaluate clinical outcomes of fluoroscopic removal of retrievable self-expandable metal stents (SEMSs) for malignant oesophageal strictures, to compare clinical outcomes of three different removal techniques, and to identify predictive factors of successful removal by the standard technique (primary technical success). METHODS: A total of 137 stents were removed from 128 patients with malignant oesophageal strictures. Primary overall technical success and removal-related complications were evaluated. Logistic regression models were constructed to identify predictive factors of primary technical success. RESULTS: Primary technical success rate was 78.8 % (108/137). Complications occurred in six (4.4 %) cases. Stent location in the upper oesophagus (P=0.004), stricture length over 8 cm (P=0.030), and proximal granulation tissue (P<0.001) were negative predictive factors of primary technical success. If granulation tissue was present at the proximal end, eversion technique was more frequently required (P=0.002). CONCLUSIONS: Fluoroscopic removal of retrievable SEMSs for malignant oesophageal strictures using three different removal techniques appeared to be safe and easy. The standard technique is safe and effective in the majority of patients. The presence of proximal granulation tissue, stent location in the upper oesophagus, and stricture length over 8 cm were negative predictive factors for primary technical success by standard extraction and may require a modified removal technique. KEY POINTS: • Fluoroscopic retrievable SEMS removal is safe and effective. • Standard removal technique by traction is effective in the majority of patients. • Three negative predictive factors of primary technical success were identified. • Caution should be exercised during the removal in those situations. • Eversion technique is effective in cases of proximal granulation tissue.


Assuntos
Remoção de Dispositivo/métodos , Estenose Esofágica/terapia , Stents , Feminino , Fluoroscopia , Humanos , Masculino , Metais , Pessoa de Meia-Idade , Resultado do Tratamento
15.
J Vasc Interv Radiol ; 28(11): 1584-1591, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28893465

RESUMO

PURPOSE: To assess the long-term outcomes of covered retrievable self-expandable metallic stent (REMS) placement for recurrent benign urethral stricture and to compare the outcomes associated with 3 types of covered REMSs. MATERIALS AND METHODS: A retrospective study was performed in 54 male patients in whom 114 REMSs were placed between November 1998 and December 2016. These included 26 polyurethane-covered REMSs in 13 patients (group A), 47 internally polytetrafluoroethylene (PTFE)-covered REMSs in 21 patients (group B), and 41 externally PTFE-covered REMSs in 20 patients (group C). The outcomes were analyzed and compared between the groups. RESULTS: Overall clinical success was achieved in 14 of the 54 patients (24%) at 5-year follow-up (group A, 12%; group B, 19%; group C, 40%). The overall complication rate was 60.5%, and the complication rate was significantly higher in group B than in groups A or C (group A vs B, P = .018; group B vs C, P = .002). The median stent indwelling time and maintained patency period were 3.1 months and 108 months, respectively. In multivariate analysis, stent indwelling time was the only significant factor associated with maintained patency. CONCLUSIONS: The long-term outcome of covered REMSs has not achieved the desired success rate for the standard treatment of recurrent urethral stricture. However, externally PTFE-covered REMSs showed a better long-term outcome than the other studied types.


Assuntos
Stents Metálicos Autoexpansíveis , Estreitamento Uretral/cirurgia , Adolescente , Adulto , Idoso , Materiais Revestidos Biocompatíveis , Feminino , Humanos , Masculino , Metais , Pessoa de Meia-Idade , Politetrafluoretileno , Poliuretanos , Recidiva , Estudos Retrospectivos , Resultado do Tratamento
16.
J Vasc Interv Radiol ; 28(8): 1147-1153, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28291717

RESUMO

PURPOSE: To evaluate the frequency, severity, and clinical significance of stent abutment (SA) after gastroduodenal stent placement in patients with gastric outlet obstruction caused by unresectable gastric cancer. MATERIALS AND METHODS: A retrospective study was conducted in a single tertiary referral university hospital to identify the incidence and clinical significance of SA in 318 patients who underwent self-expandable metallic stent placement. SA was defined as abutment of the distal end of the stent to the duodenal wall and/or superior duodenal flexure. The outcomes included technical and clinical success, complications, repeat intervention, stent patency, and survival. RESULTS: A total of 318 patients, 107 with SA (33.6%) and 211 without, were included. SA occurred partially (n = 64; 59.8%) and completely (n = 43; 40.2%). The technical and clinical outcomes and survival were similar in the groups with and without SA. Food impaction and resultant repeat intervention rates were higher in the SA group than in the non-SA group (P < .001 and P < .001, respectively), and were associated with complete SA (P = .007). Stent patency rate was lower in the SA group than in the non-SA group (P = .003). CONCLUSIONS: SA was associated with increased food impaction, resulting in a greater incidence of stent malfunction and shorter stent patency compared with a lack of SA. The concept of SA may be useful for the improvement of stent patency and avoidance of food impaction.


Assuntos
Obstrução da Saída Gástrica/etiologia , Obstrução da Saída Gástrica/terapia , Falha de Prótese , Stents/efeitos adversos , Neoplasias Gástricas/complicações , Idoso , Idoso de 80 Anos ou mais , Feminino , Obstrução da Saída Gástrica/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Cuidados Paliativos , Desenho de Prótese , Retratamento , Estudos Retrospectivos , Neoplasias Gástricas/mortalidade , Resultado do Tratamento
17.
J Vasc Interv Radiol ; 28(8): 1141-1146, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28283402

RESUMO

PURPOSE: To evaluate safety and effectiveness of fluoroscopic balloon dilation (FBD) for treating postoperative nonanastomotic strictures in proximal small bowel. MATERIALS AND METHODS: Data of 44 patients (26 men and 18 women; mean age, 53.7 y ± 13.0) treated with FBD for postoperative nonanastomotic strictures in the proximal small bowel between January 2000 and February 2016 were retrospectively reviewed. Site of stricture was located in the first portion of duodenum in 8 (18.2%) patients, second portion of duodenum in 8 (18.2%) patients, third portion of duodenum in 1 (2.3%) patient, fourth portion of duodenum in 1 (2.3%) patient, and proximal jejunum in 26 (59.1%) patients. Mean distance between the most anal-side lesion and the oral cavity was 63.9 cm ± 15.0. RESULTS: Technical success was achieved in 39 (88.6%) patients. Mean stricture length was 3.0 cm ± 1.8. Technical failure because of inability to negotiate the guide wire through the stricture occurred in 5 (13.6%) patients. Complete resolution of obstructive symptoms and resumption of oral intake of soft or solid food within 3 days occurred in 34 patients after 1 (n = 32) or 2 (n = 2) FBD sessions, rendering a clinical success rate of 87.2%. There were no major complications directly related to FBD. Median follow-up period was 1,406 days (interquartile range, 594-2,236 d). Nine (26.5%) patients had recurrence within a median 47 days (interquartile range, 20-212 d). CONCLUSIONS: FBD may be safe and effective for treating postoperative nonanastomotic strictures in the proximal small bowel.


Assuntos
Dilatação/métodos , Enteropatias/terapia , Intestino Delgado , Complicações Pós-Operatórias/terapia , Constrição Patológica , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
18.
Acta Radiol ; 58(8): 959-963, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28084810

RESUMO

Background Fluoroscopic or endoscopic placement of metallic stents is used as a safe, non-surgical, palliative treatment option for malignant gastroduodenal obstructions. However, endoscopic stent placement is not always feasible, due to the tight or tortuous stricture of the obstructed area and insufficient visualization of the stomach due to remnant food material. Purpose To assess the technical feasibility and clinical outcomes of fluoroscopic-guided stent placement in malignant gastroduodenal obstructions following the technical failure of endoscopic stent placement. Material and Methods In all, 19 patients (14 men, 5 women; age range, 36-85 years) were referred due to technical failures of tentative endoscopic stent placement. Indications were failure to pass the guide wire through the obstruction (n = 13), failure to reach the stricture lesion due to short endoscope (n = 5), and acute angulation of the stricture lesion (n = 1). Data were retrospectively collected regarding the technical and clinical success of the fluoroscopy, the dysphagia score before and after stent placement, and major complications and their management. Results Fluoroscopic stent placement was technically successful in 15/19 patients (79%). Failures were due to complete obstruction (n = 3) and acute angulation of the stricture lesion (n = 1). Clinical success was achieved in all 15 patients with successful stent placement. The dysphagia score significantly improved after stent placement ( P < 0.001). Complications occurred in 4/15 patients (27%), including tumor overgrowth (n = 2), stent collapse (n = 1), and jaundice (n = 1). Conclusion Fluoroscopic stent placement in malignant gastroduodenal obstructions following a technical failure of endoscopic stent placement is technically feasible and has an acceptable clinical outcome.


Assuntos
Obstrução da Saída Gástrica/patologia , Obstrução da Saída Gástrica/cirurgia , Radiografia Intervencionista , Stents , Neoplasias Gástricas/patologia , Neoplasias Gástricas/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Fluoroscopia , Obstrução da Saída Gástrica/diagnóstico por imagem , Humanos , Masculino , Metais , Pessoa de Meia-Idade , Estudos Retrospectivos , Neoplasias Gástricas/diagnóstico por imagem , Resultado do Tratamento
19.
Acta Radiol ; 58(5): 565-572, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-27687252

RESUMO

Background Self-expandable metallic stent (SEMS) placement is a well-established palliative treatment approach for malignant gastroduodenal obstruction. In patients with a long (>10 cm) stricture, multiple stents placed in an overlapping fashion are often required. Purpose To investigate the outcomes of overlapping SEMS placement for the palliative treatment of malignant gastroduodenal obstruction in patients with a long (>10 cm) stricture. Material and Methods The medical records of 40 patients who underwent fluoroscopic overlapping SEMS placement for malignant gastroduodenal obstruction due to a long (>10 cm) stricture were reviewed. Results The technical and clinical success rates were 100% and 65.0%, respectively. The mean length of the stricture was 17.0 ± 4.7 cm and the mean number of stents placed in each patient was 2.2 ± 0.5. Metastatic cancer (odds ratio [OR], 0.315; P = 0.018), Eastern Cooperative Oncology Group (ECOG) score ≥3 (OR, 0.018; P = 0.006), and carcinomatosis with ascites (OR, 0.025; P = 0.017) were independent predictors of poor clinical success. The rates of minor and major complications were 27.5% and 2.5%, respectively. The median stent patency and survival were 33 days (interquartile range [IQR], 19-60 days) and 35 days (IQR, 19-73 days), respectively. An ECOG score ≥3 was an independent predictor of a poor survival outcome (hazard ratio, 4.681; P < 0.001). Conclusion Overlapping SEMS placement may be safe and effective for the palliative treatment of malignant gastroduodenal obstruction in patients with a long (>10 cm) stricture.


Assuntos
Obstrução da Saída Gástrica/etiologia , Obstrução da Saída Gástrica/cirurgia , Cuidados Paliativos/métodos , Stents Metálicos Autoexpansíveis , Neoplasias Gástricas/complicações , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Estômago/cirurgia , Resultado do Tratamento
20.
J Korean Med Sci ; 32(7): 1062-1071, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28581260

RESUMO

Esophageal stents have been used to palliate patients with dysphagia caused by esophageal cancer. Early rigid plastic prostheses have been associated with a high risk of complications. However, with the development of self-expanding stents, it has developed into a widely accepted method for treating malignant esophageal strictures and esophagorespiratory fistulas (ERFs). The present review covers various aspects of self-expanding metallic stent placement for palliating esophageal cancer, including its types, placement procedures, indications, contraindications, complications, and some of innovations that will become available in the future.


Assuntos
Transtornos de Deglutição/cirurgia , Neoplasias Esofágicas/patologia , Estenose Esofágica/cirurgia , Cuidados Paliativos/métodos , Stents , Transtornos de Deglutição/complicações , Neoplasias Esofágicas/cirurgia , Estenose Esofágica/patologia , Esôfago/patologia , Esôfago/cirurgia , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA