Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Nature ; 627(8002): 80-87, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38418888

RESUMO

Integrated microwave photonics (MWP) is an intriguing technology for the generation, transmission and manipulation of microwave signals in chip-scale optical systems1,2. In particular, ultrafast processing of analogue signals in the optical domain with high fidelity and low latency could enable a variety of applications such as MWP filters3-5, microwave signal processing6-9 and image recognition10,11. An ideal integrated MWP processing platform should have both an efficient and high-speed electro-optic modulation block to faithfully perform microwave-optic conversion at low power and also a low-loss functional photonic network to implement various signal-processing tasks. Moreover, large-scale, low-cost manufacturability is required to monolithically integrate the two building blocks on the same chip. Here we demonstrate such an integrated MWP processing engine based on a 4 inch wafer-scale thin-film lithium niobate platform. It can perform multipurpose tasks with processing bandwidths of up to 67 GHz at complementary metal-oxide-semiconductor (CMOS)-compatible voltages. We achieve ultrafast analogue computation, namely temporal integration and differentiation, at sampling rates of up to 256 giga samples per second, and deploy these functions to showcase three proof-of-concept applications: solving ordinary differential equations, generating ultra-wideband signals and detecting edges in images. We further leverage the image edge detector to realize a photonic-assisted image segmentation model that can effectively outline the boundaries of melanoma lesion in medical diagnostic images. Our ultrafast lithium niobate MWP engine could provide compact, low-latency and cost-effective solutions for future wireless communications, high-resolution radar and photonic artificial intelligence.


Assuntos
Micro-Ondas , Nióbio , Óptica e Fotônica , Óxidos , Fótons , Inteligência Artificial , Diagnóstico por Imagem/instrumentação , Diagnóstico por Imagem/métodos , Melanoma/diagnóstico por imagem , Melanoma/patologia , Óptica e Fotônica/instrumentação , Óptica e Fotônica/métodos , Radar , Tecnologia sem Fio , Humanos
2.
J Biol Chem ; 299(4): 103025, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36805336

RESUMO

Gastric cancer is one of the cancers with high morbidity and mortality worldwide. The aryl sulfonamide indisulam inhibits the proliferation of several types of cancer cells through its function as a molecular glue to promote the ubiquitination and degradation of RNA-binding motif protein 39 (RBM39). However, it is unknown whether and how indisulam regulates the migration of cancer cells. In this work, using label-free quantitative proteomics, we discover that indisulam significantly attenuates N-cadherin, a marker for epithelial to mesenchymal transition and migration of cancer cells. Our bioinformatics analysis and biochemical experiments reveal that indisulam promotes the interaction between the zinc finger E-box-binding homeobox 1 (ZEB1), a transcription factor of N-cadherin, and DCAF15, a substrate receptor of CRL4 E3 ubiquitin ligase, and enhances ZEB1 ubiquitination and proteasomal degradation. In addition, our cell line-based experiments demonstrate that indisulam inhibits the migration of gastric cancer cells in a ZEB1-dependent manner. Analyses of patient samples and datasets in public databases reveal that tumor tissues from patients with gastric cancer express high ZEB1 mRNA and this high expression reduces patient survival rate. Finally, we show that treatment of gastric tumor samples with indisulam significantly reduces ZEB1 protein levels. Therefore, this work discloses a new mechanism by which indisulam inhibits the migration of gastric cancer cells, indicating that indisulam exhibits different biological functions through distinct signaling molecules.


Assuntos
Neoplasias Gástricas , Humanos , Neoplasias Gástricas/tratamento farmacológico , Neoplasias Gástricas/genética , Neoplasias Gástricas/metabolismo , Fatores de Transcrição/genética , Fatores de Transcrição/metabolismo , Linhagem Celular Tumoral , Transição Epitelial-Mesenquimal/genética , Ubiquitinação , Sulfonamidas/farmacologia , Homeobox 1 de Ligação a E-box em Dedo de Zinco/genética , Homeobox 1 de Ligação a E-box em Dedo de Zinco/metabolismo , Movimento Celular , Caderinas/genética , Caderinas/metabolismo
3.
J Appl Clin Med Phys ; 25(1): e14226, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38009990

RESUMO

PURPOSE: The purpose of this study was to evaluate the performance of our quality assurance (QA) automation system and to evaluate the machine performance of a new type linear accelerator uRT-linac 506c within 6 months using this system. METHODS: This QA automation system consists of a hollow cylindrical phantom with 18 steel balls in the phantom surface and an analysis software to process electronic portal imaging device (EPID) measurement image data and report the results. The performance of the QA automation system was evaluated by the tests of repeatability, archivable precision, detectability of introduced errors, and the impact of set-up errors on QA results. The performance of this linac was evaluated by 31 items using this QA system over 6 months. RESULTS: This QA system was able to automatically deliver QA plan, EPID image acquisition, and automatic analysis. All images acquiring and analysis took approximately 4.6 min per energy. The preset error of 0.1 mm in multi-leaf collimator (MLC) leaf were detected as 0.12 ± 0.01 mm for Bank A and 0.10 ± 0.01 mm in Bank B. The 2 mm setup error was detected as -1.95 ± 0.01 mm, -2.02 ± 0.01 mm, 2.01 ± 0.01 mm for X, Y, Z directions, respectively. And data from the tests of repeatability and detectability of introduced errors showed the standard deviation were all within 0.1 mm and 0.1°. and data of the machine performance were all within the tolerance specified by AAPM TG-142. CONCLUSIONS: The QA automation system has high precision and good performance, and it can improve the QA efficiency. The performance of the new accelerator has also performed very well during the testing period.


Assuntos
Aceleradores de Partículas , Radioterapia de Intensidade Modulada , Humanos , Software , Radioterapia de Intensidade Modulada/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Imagens de Fantasmas , Automação , Garantia da Qualidade dos Cuidados de Saúde
4.
Opt Lett ; 48(9): 2218-2221, 2023 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-37126238

RESUMO

Waveguide crossings are elementary passive components for signal routing in photonic integrated circuits. Here, we design and characterize two multimode interferometer (MMI)-based waveguide crossings to serve the various routing directions in the anisotropic x-cut thin-film lithium niobate (TFLN) platform. To address the large measurement uncertainties in traditional cut-back characterization methods, we propose and demonstrate a resonator-assisted approach that dramatically reduces the uncertainty of insertion loss measurement (< 0.021 dB) and the lower bound of crosstalk measurement (-60 dB) using only two devices. Based on this approach, we demonstrate and verify TFLN waveguide crossings with insertion losses of < 0.070 dB and crosstalk of < -50 dB along all three routing directions at 1550 nm. The low-loss and low-crosstalk waveguide crossings in this work, together with the simple and efficient characterization strategy, could provide important layout design flexibility for future large-scale classical and quantum TFLN photonic circuits.

5.
J Appl Clin Med Phys ; 24(10): e14050, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37248800

RESUMO

To investigate the difference of the fluence map optimization (FMO) and Stochastic platform optimization (SPO) algorithm in a newly-introduced treatment planning system (TPS). METHODS: 34 cervical cancer patients with definitive radiation were retrospectively analyzed. Each patient has four plans: FMO with fixed jaw plans (FMO-FJ) and no fixed jaw plans (FMO-NFJ); SPO with fixed jaw plans (SPO-FJ) and no fixed jaw plans (SPO-NFJ). Dosimetric parameters, Modulation Complexity Score (MCS), Gamma Pass Rate (GPR) and delivery time were analyzed among the four plans. RESULTS: For target coverage, SPO-FJ plans are the best ones (P ≤ 0.00). FMO plans are better than SPO-NFJ plans (P ≤ 0.00). For OARs sparing, SPO-FJ plans are better than FMO plans for mostly OARs (P ≤ 0.04). Additionally, SPO-FJ plans are better than SPO-NFJ plans (P ≤ 0.02), except for rectum V45Gy. Compared to SPO-NFJ plans, the FMO plans delivered less dose to bladder, rectum, colon V40Gy and pelvic bone V40Gy (P ≤ 0.04). Meanwhile, the SPO-NFJ plans showed superiority in MU, delivery time, MCS and GPR in all plans. In terms of delivery time and MCS, the SPO-FJ plans are better than FMO plans. FMO-FJ plans are better than FMO-NFJ plans in delivery efficiency. MCSs are strongly correlated with PCTV length, which are negatively with PCTV length (P ≤ 0.03). The delivery time and MUs of the four plans are strongly correlated (P ≤ 0.02). Comparing plans with fixed or no fixed jaw in two algorithms, no difference was found in FMO plans in target coverage and minor difference in Kidney_L Dmean, Mu and delivery time between PCTV width≤15.5 cm group and >15.5 cm group. For SPO plans, SPO-FJ plans showed more superiority in target coverage and OARs sparing than the SPO-NFJ plans in the two groups. CONCLUSIONS: SPO-FJ plans showed superiority in target coverage and OARs sparing, as well as higher delivery efficiency in the four plans.


Assuntos
Radioterapia de Intensidade Modulada , Neoplasias do Colo do Útero , Feminino , Humanos , Neoplasias do Colo do Útero/radioterapia , Estudos Retrospectivos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Órgãos em Risco
6.
Phys Rev Lett ; 123(16): 165701, 2019 Oct 18.
Artigo em Inglês | MEDLINE | ID: mdl-31702358

RESUMO

The topological edge state (TES) in a one-dimensional optical lattice has exhibited robust field localization or waveguiding against the structural perturbations that would give rise to fault-tolerant photonic integrations. However, the zero mode as a kind of TES usually deviates from the exact zero-energy state in a finite Hermitian lattice due to the coupling between these edge states, which inevitably weaken the topological protection. Here, we first show such a breakup of zero modes in finite Su-Schriffer-Heeger optical lattices and then reveal their recovery by introducing non-Hermitian degeneracies with parity-time (PT) symmetry. We carry out experiments in a finite silicon waveguide lattice, where a passive-PT symmetry was implemented with carefully controlled lossy silicon waveguides. The experimental results are fully compatible with the theoretical prediction. Our results show that the topological property of an open system can be tuned by non-Hermitian lattice engineering, which offers a route to enhance the topological protection in a finite system.

7.
Opt Lett ; 43(11): 2482-2485, 2018 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-29856409

RESUMO

Very sharp 90°micro-bends for adiabatic optical wave propagation in multimode waveguides are demonstrated by an inverse design method, and the devices are fabricated on a silicon-on-insulator platform. The compact bending structures are based on digital waveguide metastructures with footprints as small as 2.6 µm×2.6 µm. For waveguides with widths of 2 µm and bending radii of only 1 µm, the TE00 mode is able to turn around the sharp corner with 1 dB loss and >20 dB suppression ratio to higher-order modes. The transmission spectra of the devices are measured with ∼1 dB loss over a 40 nm bandwidth which are consistent with the numerical simulations.

8.
PLoS Comput Biol ; 13(5): e1005533, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28531187

RESUMO

Mitotic rounding during cell division is critical for preventing daughter cells from inheriting an abnormal number of chromosomes, a condition that occurs frequently in cancer cells. Cells must significantly expand their apical area and transition from a polygonal to circular apical shape to achieve robust mitotic rounding in epithelial tissues, which is where most cancers initiate. However, how cells mechanically regulate robust mitotic rounding within packed tissues is unknown. Here, we analyze mitotic rounding using a newly developed multi-scale subcellular element computational model that is calibrated using experimental data. Novel biologically relevant features of the model include separate representations of the sub-cellular components including the apical membrane and cytoplasm of the cell at the tissue scale level as well as detailed description of cell properties during mitotic rounding. Regression analysis of predictive model simulation results reveals the relative contributions of osmotic pressure, cell-cell adhesion and cortical stiffness to mitotic rounding. Mitotic area expansion is largely driven by regulation of cytoplasmic pressure. Surprisingly, mitotic shape roundness within physiological ranges is most sensitive to variation in cell-cell adhesivity and stiffness. An understanding of how perturbed mechanical properties impact mitotic rounding has important potential implications on, amongst others, how tumors progressively become more genetically unstable due to increased chromosomal aneuploidy and more aggressive.


Assuntos
Forma Celular/fisiologia , Células Epiteliais/citologia , Células Epiteliais/fisiologia , Mitose/fisiologia , Animais , Linhagem Celular , Biologia Computacional , Drosophila , Humanos , Modelos Biológicos
9.
J Appl Clin Med Phys ; 19(5): 609-615, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30058257

RESUMO

PURPOSE: The purpose of this study was to study the influence of the minimum segment width (MSW) on volumetric modulated arc therapy (VMAT) plan quality, delivery accuracy, and efficiency for cervical cancer treatment. METHODS: Nineteen patients with cervical cancer were randomly selected to design VMAT plans. Three VMAT plans were generated for each patient incorporating MSWs of 0.5, 1.0, and 1.5 cm while other planning parameters remained constant using the Monaco treatment planning system (TPS) with 6 MV X rays delivered from an Elekta Synergy linear accelerator. Plan quality and delivery efficiency were evaluated based on dose-volume histograms (DVHs), control points, monitor units (MUs), dosimetric measurement verification results, and plan delivery time. RESULTS: Except for the small difference in target dose coverage and maximum dose, there were no statistically significant differences between the other dosimetric parameters in the planning target volumes. The 1.0 and 1.5 cm MSW plans showed lower maximum doses to the spinal cord than the 0.5 cm plan; doses to other organs at risks were similar regardless of MSWs. The mean reductions of total MUs when compared with the 0.5 cm plan were 14.5 ± 6.1% and 20.9 ± 7.9% for MSWs of 1.0 and 1.5 cm, respectively. The calculated gamma indices using the 3% and 3 mm criteria were 96.2 ± 0.6%, 97.0 ± 0.6%, and 97.6 ± 0.6% for the 0.5, 1.0 and 1.5 cm MSW plans, respectively. The plan delivery times decreased with increasing MSWs (p < 0.05). CONCLUSION: Increasing the MSW allows for improved plan delivery accuracy and efficiency without significantly affecting the VMAT plan quality. MSWs of 1.0 and 1.5 cm improved the plan quality, delivery accuracy, and efficiency for cervical VMAT radiation therapy.


Assuntos
Neoplasias do Colo do Útero , Adulto , Idoso , Feminino , Humanos , Pessoa de Meia-Idade , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada
10.
Opt Lett ; 42(4): 855-858, 2017 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-28198882

RESUMO

Integrated optical power splitters are one of the fundamental building blocks in photonic integrated circuits. Conventional multimode interferometer-based power splitters are widely used as they have reasonable footprints and are easy to fabricate. However, it is challenging to realize arbitrary split ratios, especially for multi-outputs. In this Letter, an ultra-compact power splitter with a QR code-like nanostructure is designed by a nonlinear fast search method. The highly functional structure is composed of a number of freely designed square pixels with the size of 120×120 nm which could be either dielectric or air. The light waves are scattered by a number of etched squares with optimized locations, and the scattered waves superimpose at the outputs with the desired power ratio. We demonstrate 1×2 splitters with 1:1, 1:2, and 1:3 split ratios, and a 1×3 splitter with the ratio of 1:2:1. The footprint for all the devices is only 3.6×3.6 µm. Well-controlled split ratios are measured for all the cases. The measured transmission efficiencies of all the splitters are close to 80% over 30 nm wavelength range.

11.
Opt Express ; 23(19): 24257-64, 2015 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-26406631

RESUMO

Monochromaticity and directionality are two key characteristics of lasers. However, the combination of directional emission and single-mode operation is quite challenging, especially for the on-chip devices. Here we propose a microdisk laser with single-mode operation and directional emissions by exploiting the recent developments associated with parity-time (PT) symmetry. This is accomplished by introducing one-dimensional periodic gain and loss into a circular microdisk, which induces a coupling between whispering gallery modes with different radial numbers. The lowest threshold mode is selected at the positions with least initial wavelength difference. And the directional emissions are formed by the introduction of additional grating vectors by the periodic distribution of gain and loss regions. We believe this research will impact the practical applications of on-chip microdisk lasers.

12.
Adv Mater ; 36(17): e2308840, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38181412

RESUMO

On-chip optical microresonators are essential building blocks in integrated optics. The ability to arbitrarily engineer their resonant frequencies is crucial for exploring novel physics in synthetic frequency dimensions and practical applications like nonlinear optical parametric processes and dispersion-engineered frequency comb generation. Photonic crystal ring (PhCR) resonators are a versatile tool for such arbitrary frequency engineering, by controllably creating mode splitting at selected resonances. To date, these PhCRs have mostly been demonstrated in isotropic photonic materials, while such engineering can be significantly more complicated in anisotropic platforms that often offer more fruitful optical properties. Here, the spectral engineering of chip-scale optical microresonators is realized in the anisotropic lithium niobate (LN) crystal by a gradient design that precisely compensates for variations in both refractive index and perturbation strength. Controllable frequency splitting is experimentally demonstrated at single and multiple selected resonances in LN PhCR resonators with different sizes, while maintaining high quality-factors up to 1 × 106. Moreover, a sharp boundary is experimentally constructed in the synthetic frequency dimension based on an actively modulated x-cut LN gradient-PhCR, opening up new paths toward the arbitrary control of electro-optic comb spectral shapes and exploration of novel physics in the frequency degree of freedom.

13.
Phys Med ; 117: 103204, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38154373

RESUMO

PURPOSE: The purpose of this study was to accurately predict or classify the beam GPR with an ensemble model by using machine learning for SBRT(VMAT) plans. METHODS: A total of 128 SBRT VMAT plans with 330 arc beams were retrospectively selected, and 216 radiomics and 34 plan complexity features were calculated for each arc beam. Three models for GPR prediction and classification using support vector machine algorithm were as follows: (1) plan complexity feature-based model (plan model); (2) radiomics feature-based model (radiomics model); and (3) an ensemble model combining the two models (ensemble model). The prediction performance was evaluated by calculating the mean absolute error (MAE), root mean square error (RMSE), and Spearman's correlation coefficient (SC), and the classification performance was measured by calculating the area under the receiver operating characteristic curve (AUC), accuracy, specificity, and sensitivity. RESULTS: The MAE, RMSE and SC at the 2 %/2 mm gamma criterion in the test dataset were 1.4 %, 2.57 %, and 0.563, respectively, for the plan model; 1.42 %, and 2.51 %, and 0.508, respectively, for the radiomics model; and 1.33 %, 2.49 %, and 0.611, respectively, for the ensemble model. The accuracy, specificity, sensitivity, and AUC at the 2 %/2 mm gamma criterion in the test dataset were 0.807, 0.824, 0.681, and 0.854, respectively, for the plan model; 0.860, 0.893, 0.624, and 0.877, respectively, for the radiomics model; and 0.852, 0.871, 0.710, and 0.896, respectively, for the ensemble model. CONCLUSIONS: The ensemble model can improve the prediction and classification performance for the GPR of SBRT (VMAT).


Assuntos
Radiocirurgia , Radioterapia de Intensidade Modulada , Estudos Retrospectivos , Algoritmos , Aprendizado de Máquina , Raios gama , Etoposídeo
14.
Front Public Health ; 11: 1167234, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37521991

RESUMO

Background: Adolescent depression has become a leading problem around the world, especially as the COVID-19 pandemic has remained prevalent and heavily influenced people's mental health. While gender difference has always been a topic in the field of psychiatry, there are cultural differences across the world that must be taken into account. The current study is examining gender differences in symptoms of Chinese adolescents with depression. Methods: The sample was obtained from a total of 574 adolescent patients (172 males and 402 females) diagnosed with depression following the DSM-IV/ICD-10 diagnostic criteria; patients who also had other severe mental or physical illnesses were excluded. The ages of participants ranged from 10 to 19 years. Additionally, independent t-test and one-way ANOVA were used to examine differences in symptoms between different gender and age groups. The LPA was used to examine whether females and males were having different patterns of symptoms. Results: Our analysis showed that compared to males, females exhibited higher rates of depression and more severe depressive symptoms across age groups. Likewise, the analysis also revealed an earlier onset of depression among Chinese adolescents compared to that in Western countries in previous studies. Finally, the LPA showed that mild to moderate depression was predominant in male patients, while severe depression was predominant in female patients. Conclusion: This study highlights the gender differences in the prevalence and severity of depressive symptoms in Chinese adolescents. The current study highlighted the importance of gender equality and developing gender-friendly interventions in maintaining the overall mental health of adolescents in China.


Assuntos
Depressão , Fatores Sexuais , Adolescente , Feminino , Humanos , Masculino , Depressão/psicologia , População do Leste Asiático , Criança
15.
Technol Cancer Res Treat ; 22: 15330338231169601, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37078143

RESUMO

BACKGROUND: To analyze the relationship between the rotational and residual setup errors and the dose deviation on nasopharyngeal carcinoma (NPC) treated by helical tomotherapy (HT). METHODS: From 25 July 2017 to 20 August 2019, 16 treated NPC patients were enrolled in the study. These patients were scanned with full target range megavoltage computed tomography (MVCT) every other day. Adaptive radiotherapy function application software MIM7.1.3 were used to accumulate the actual dose. The dose deviation with the initial plan dose of the patients' target and organs at risk (OAR) were compared, and the correlation between the dose change and the setup errors (rotational setup errors and neck residual setup error) was analyzed. RESULTS: Translational setup errors increased farther away from the head. Statistically significant difference among 3 groups was achieved in the directions of left-right (P < .001) and anteroposterior (P < .001) by analysis of variance test. Compared with the initial plan dose, the actual accumulated dose of the target area decreased with the actual exposure dose of the OAR increased. However, most of the dosimetric parameters differed by less than 5%. No correlation was found between dose deviation values and the translational setup errors of target. However, sagittal rotational setup errors (pitch) had a positive relationship (P < .05) with the avearge dose of PTVnd (L) (r = 0.885), PTVnd(R) (r = 0.547) PTV1(r = 0.633) and PTV2(r = 0.584). Transverse rotational setup errors (roll) had a positive relationship (P < .05) with the avearge dose of PTVnd(R) (r = 0.593), PTV1(r = 0.505) and PTV2(r = 0.662). CONCLUSIONS: Dose deviation between the actual accumulated and initial plan is not negligible, but most indicators difference is less than 5%, NPC patients treated by HT with MVCT correction setup errors every other day did not need adaptive radiotherapy model unless got rapid tumor shrinkage or weight loss. Moreover, to minimize the dose deviation, more attention should be paid to the reduction of pitch, roll, and residual error of cervical vertebrae during body positioning.


Assuntos
Neoplasias Nasofaríngeas , Radioterapia Conformacional , Radioterapia de Intensidade Modulada , Humanos , Radioterapia de Intensidade Modulada/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Carcinoma Nasofaríngeo/radioterapia , Radioterapia Conformacional/métodos , Dosagem Radioterapêutica , Erros de Configuração em Radioterapia/prevenção & controle , Neoplasias Nasofaríngeas/radioterapia
16.
Phys Med Biol ; 67(12)2022 06 08.
Artigo em Inglês | MEDLINE | ID: mdl-35588723

RESUMO

Objective.To develop and validate a graphics processing unit (GPU) based superposition Monte Carlo (SMC) code for efficient and accurate dose calculation in magnetic fields.Approach.A series of mono-energy photons ranging from 25 keV to 7.7 MeV were simulated with EGSnrc in a water phantom to generate particle tracks database. SMC physics was extended with charged particle transport in magnetic fields and subsequently programmed on GPU as gSMC. Optimized simulation scheme was designed by combining variance reduction techniques to relieve the thread divergence issue in general GPU-MC codes and improve the calculation efficiency. The gSMC code's dose calculation accuracy and efficiency were assessed through both phantoms and patient cases.Main results.gSMC accurately calculated the dose in various phantoms for bothB = 0 T andB = 1.5 T, and it matched EGSnrc well with a root mean square error of less than 1.0% for the entire depth dose region. Patient cases validation also showed a high dose agreement with EGSnrc with 3D gamma passing rate (2%/2 mm) large than 97% for all tested tumor sites. Combined with photon splitting and particle track repeating techniques, gSMC resolved the thread divergence issue and showed an efficiency gain of 186-304 relative to EGSnrc with 10 CPU threads.Significance.A GPU-superposition Monte Carlo code called gSMC was developed and validated for dose calculation in magnetic fields. The developed code's high calculation accuracy and efficiency make it suitable for dose calculation tasks in online adaptive radiotherapy with MR-LINAC.


Assuntos
Campos Magnéticos , Planejamento da Radioterapia Assistida por Computador , Humanos , Método de Monte Carlo , Imagens de Fantasmas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos
17.
Technol Cancer Res Treat ; 21: 15330338211072680, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35023424

RESUMO

Background and Purpose: In this study, the absolute dose achievable between helical tomotherapy (HT) plans and RapidArc (RA) plans for total dura mater irradiation (TDMI) was compared. Materials and methods: A planning study was conducted on nine children's case datasets with dura mater metastasis of neuroblastoma. The target included the entire calvarium and skull base and formed a closed volume with a certain thickness around the brain. HT and RA plans with four coplanar full arcs (RA4) with half-field technique were generated for the comparison of absolute dose achievable. In total, 30.6 Gy was prescribed as D95% (ie, dose to 95% of PTV volume). Results: In the dosimetric comparison between the two modalities, HT provided more homogenous dose distribution than RA4 (mean HI5-95%: 1.046 vs 1.088, P < .001). The V107% and D2Gy of PTV in HT versus RA4 were 3.06% versus 30.47% and 32.59 Gy versus 33.45 Gy, respectively. HT reduced the Dmean and V5Gy of the brain, brainstem, and hippocampus by 25%-48% and 27%-56% compared with RA4, respectively. Conclusion: Both techniques could provide sufficient coverage for targets, but HT offered more homogenous dose to PTV and lower dose to the central region of the brain involving the brainstem and hippocampus. RA4 could be completed in a shorter time with lower MUs, but with relatively higher dose to the brain or hippocampus. In terms of dosimetry, HT may improve long-term cognitive decline in these young pediatric patients with TDMI.


Assuntos
Irradiação Craniana , Dura-Máter/patologia , Dura-Máter/efeitos da radiação , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Radioterapia de Intensidade Modulada/normas , Fatores Etários , Neoplasias Encefálicas/diagnóstico , Neoplasias Encefálicas/radioterapia , Criança , Fracionamento da Dose de Radiação , Humanos , Tratamentos com Preservação do Órgão , Radiometria , Radioterapia Guiada por Imagem , Resultado do Tratamento
18.
Chin J Cancer ; 29(2): 217-22, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20109355

RESUMO

BACKGROUND AND OBJECTIVE: To ensure the accuracy of dose calculation for radiation treatment plans is an important part of quality assurance (QA) procedures for radiotherapy. This study evaluated the Monitor Units (MU) calculation accuracy of a third-party QA software and a 3-dimensional treatment planning system (3D TPS), to investigate the feasibility and reliability of independent verification for radiation treatment planning. METHODS: Test plans in a homogenous phantom were designed with 3-D TPS, according to the International Atomic Energy Agency (IAEA) Technical Report No. 430, including open, blocked, wedge, and multileaf collimator (MLC) fields. Test plans were delivered and measured in the phantom. The delivered doses were input to the QA software and the independent calculated MUs were compared with delivery. All test plans were verified with independent calculation and phantom measurements separately, and the differences of the two kinds of verification were then compared. RESULTS: The deviation of the independent calculation to the measurements was (0.1 +/- 0.9)%, the biggest difference fell onto the plans that used block and wedge fields (2.0%). The mean MU difference between the TPS and the QA software was (0.6 +/- 1.0)%, ranging from -0.8% to 2.8%. The deviation in dose of the TPS calculation compared to the measurements was (-0.2 +/- 1.7)%, ranging from -3.9% to 2.9%. CONCLUSIONS: MU accuracy of the third-party QA software is clinically acceptable. Similar results were achieved with the independent calculations and the phantom measurements for all test plans. The tested independent calculation software can be used as an efficient tool for TPS plan verification.


Assuntos
Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Software , Algoritmos , Imagens de Fantasmas , Controle de Qualidade , Dosagem Radioterapêutica
19.
Nat Commun ; 11(1): 4862, 2020 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-32978397

RESUMO

Lead halide perovskite microlasers have been very promising for versatile optoelectronic applications. However, most perovskite microlasers are linearly polarized with uniform wavefront. The structured laser beams carrying orbital angular momentum have rarely been studied and the applications of perovskites in next-generation optical communications are thus hindered. Herein, we experimentally demonstrate the perovskite vortex microlasers with highly directional outputs and well-controlled topological charges. High quality gratings have been experimentally fabricated in perovskite film and the subsequent vertical cavity surface emitting lasers (VCSELs) with divergent angles of 3o are achieved. With the control of Archimedean spiral gratings, the wavefront of the perovskite VCSELs has been switched to be helical with topological charges of q = -4 to 4. This research is able to expand the potential applications of perovskite microlasers in hybrid integrated photonic networks, as well as optical computing.

20.
Front Oncol ; 10: 598, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32391275

RESUMO

Purpose: To aid in the selection of a suitable combination of irradiation mode and jaw width in helical tomotherapy (HT) for the treatment of nasopharyngeal carcinoma (NPC). Materials and Methods: Twenty patients with NPC who underwent radiotherapy were retrospectively selected. Four plans using a jaw width of 2.5 or 5-cm in dynamic jaw (DJ) or fix jaw (FJ) modes for irradiation were designed (2.5DJ, 2.5FJ, 5.0DJ, and 5.0FJ). The dose parameters of planning target volume (PTV) and organs at risk (OARs) of the plans were compared and analyzed, as well as the beam on time (BOT) and monitor unit (MU). The plans in each group were ranked by scoring the doses received by the OARs and the superity was assessed in combination with the planned BOT and MU. Results: The prescribed dose coverage of PTV met the clinical requirements for all plans in the four groups. The groups using a 2.5-cm jaw width or a DJ mode provided better protection to most OARs, particularly for those at the longitudinal edges of the PTV (P < 0.05). The 2.5DJ group had the best ranking for OAR-dose, followed by the 2.5FJ and 5.0DJ groups with a same score. The BOT and MU of the groups using a 5.0-cm jaw width reduced nearly 45% comparing to those of the 2.5-cm jaw groups. Conclusion: 2.5DJ has the best dose distribution, while 5.0DJ has satisfactory dose distribution and less BOT and MU that related to the leakage dose. Both 2.5DJ or 5DJ were recommended for HT treatment plan for NPC based on the center workload.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA