Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 99(1): 68-73, 2022 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-33533535

RESUMO

OBJECTIVES: This study aims to evaluate the diagnostic performance of quantitative flow ratio (QFR) pre transcatheter aortic valve implantation (TAVI) in patients with aortic valve stenosis (AS) and coronary artery disease (CAD). Post-TAVI fractional flow reserve (FFR) and instantaneous wave-free ratio (iFR) was used as reference. BACKGROUND: CAD is prevalent in patients with AS, but the hemodynamics of AS confounds evaluation using pressure wire-based assessments. QFR might be less sensitive to the presence of AS thereby allowing for CAD evaluation before aortic valve replacement. Further, QFR does not require the use of pressure wire and therefore has the potential for reducing costs and complications related to insertion of a coronary pressure wire. METHODS: The diagnostic performance of QFR in coronary angiograms from 28 patients undergoing TAVI was evaluated. In all patients, both FFR and iFR were measured pre- and immediately post-TAVI while QFR was measured pre-TAVI. RESULTS: Using post-TAVI FFR and iFR as reference the diagnostic accuracy of pre-TAVI QFR were 83% (95%CI; 68-97) and 52% (95%CI; 30-74) p = .008, respectively. CONCLUSIONS: Pre-TAVI QFR showed a good diagnostic performance using post-TAVI FFR as reference. QFR could become a wire-free, safe, and quick way of evaluating CAD in patients with severe AS undergoing TAVI.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Substituição da Valva Aórtica Transcateter , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários , Humanos , Valor Preditivo dos Testes , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
2.
Europace ; 23(12): 2020-2028, 2021 12 07.
Artigo em Inglês | MEDLINE | ID: mdl-34125232

RESUMO

AIMS: In patients with Brugada syndrome (BrS) but without spontaneous Type-1 electrocardiogram, several electrocardiographic characteristics have been studied, including the ß-angle. Previous studies suggested that the ß-angle might be useful in distinguishing BrS-patients from patients with only suggestive repolarization patterns without performing sodium channel blocker provocation testing. In this study, we aimed to determine the diagnostic value of the ß-angle in patients suspected of BrS. METHODS AND RESULTS: A large cohort (n = 1430) of consecutive patients who underwent provocation testing was evaluated. ß-angles were measured in leads V1, V2, and their corresponding positions over the second and third intercostal space. Receiver-operating characteristic curves were constructed and the diagnostic accuracy of previously reported ß-angle cut-offs were calculated and evaluated. The importance of the ß-angle for predicting the provocation test outcome was determined using a prediction model constructed with logistic regression. The optimum ß-angle cut-off in our cohort for ruling out a positive provocation test was 15°; sensitivities were 80-98% and negative predictive values were 79-96% among the right precordial leads. Previously reported ß-angle cut-offs performed less well, indicated by lower Youden indices. In the optimism-corrected prediction model [C-statistic: 0.78 (95% CI: 0.75-0.81)], the ß-angle had large value (Z-score: 2.1-10.3) and aided construction of a nomogram to predict test outcome. CONCLUSION: To predict the outcome of provocation testing for BrS, the ß-angle alone does not demonstrate strong diagnostic characteristics. However, the ß-angle is an important variable to predict provocation test outcome and thus has added value.


Assuntos
Síndrome de Brugada , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/tratamento farmacológico , Eletrocardiografia/métodos , Humanos , Curva ROC , Bloqueadores dos Canais de Sódio/uso terapêutico , Canais de Sódio
3.
Int J Mol Sci ; 22(2)2021 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-33418933

RESUMO

Patients with Brugada syndrome (BrS) can show a leftward deviation of the frontal QRS-axis upon provocation with sodium channel blockers. The cause of this axis change is unclear. In this study, we aimed to determine (1) the prevalence of this left axis deviation and (2) to evaluate its cause, using the insights that could be derived from vectorcardiograms. Hence, from a large cohort of patients who underwent ajmaline provocation testing (n = 1430), we selected patients in whom a type-1 BrS-ECG was evoked (n = 345). Depolarization and repolarization parameters were analyzed for reconstructed vectorcardiograms and were compared between patients with and without a >30° leftward axis shift. We found (1) that the prevalence of a left axis deviation during provocation testing was 18% and (2) that this left axis deviation was not explained by terminal conduction slowing in the right ventricular outflow tract (4th QRS-loop quartile: +17 ± 14 ms versus +13 ± 15 ms, nonsignificant) but was associated with a more proximal conduction slowing (1st QRS-loop quartile: +12[8;18] ms versus +8[4;12] ms, p < 0.001 and 3rd QRS-loop quartile: +12 ± 10 ms versus +5 ± 7 ms, p < 0.001). There was no important heterogeneity of the action potential morphology (no difference in the ventricular gradient), but a left axis deviation did result in a discordant repolarization (spatial QRS-T angle: 122[59;147]° versus 44[25;91]°, p < 0.001). Thus, although the development of the type-1 BrS-ECG is characterized by a terminal conduction delay in the right ventricle, BrS-patients with a left axis deviation upon sodium channel blocker provocation have an additional proximal conduction slowing, which is associated with a subsequent discordant repolarization. Whether this has implications for risk stratification is still undetermined.


Assuntos
Ajmalina/uso terapêutico , Síndrome de Brugada/tratamento farmacológico , Bloqueadores dos Canais de Sódio/uso terapêutico , Adulto , Ajmalina/farmacologia , Síndrome de Brugada/fisiopatologia , Eletrocardiografia , Potenciais Evocados/efeitos dos fármacos , Feminino , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Bloqueadores dos Canais de Sódio/farmacologia , Função Ventricular/efeitos dos fármacos
4.
Heart Vessels ; 35(12): 1735-1745, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32591894

RESUMO

Permanent pacemaker implantation (PPI) is a widely recognized complication associated with TAVI (incidence up to 20%). Smaller registries have identified several variables associated with PPI. The objective was to validate patient- and transcatheter aortic valve implantation (TAVI)-related procedural variables associated with PPI. We performed a retrospective analysis of patients from six European centers undergoing TAVI with the Edwards SAPIEN 3 prosthesis. Baseline variables and pre-procedural ECG characteristics and CT-scans were taken into account. Data for 1745 patients were collected; 191 (10.9%) required PPI after TAVI. The baseline variables pulmonary hypertension (OR 1.64; 95% CI 1.01-2.59), QRS duration > 117 ms (OR 2.58; 95% CI 1.73-3.84), right bundle branch block (RBBB; OR 5.14; 95% CI 3.39-7.72), left anterior hemi block (OR 1.92; 95% CI 1.19-3.02) and first-degree atrioventricular block (AVB, OR 1.63; 95%CI 1.05-2.46) were significantly associated with PPI. RBBB (OR 8.11; 95% CI 3.19-21.86) and first-degree AVB (OR 2.39; 95% CI 1.18-4.66) remained significantly associated in a multivariate analysis. Procedure-related variables included access site (TF; OR 1.97; 95% CI 1.07-4.05), implanted valve size (29 mm; OR 1.88; 95% CI 1.35-2.59), mean TAVI valve implantation depth below the annulus > 30% (OR 3.75; 95% CI 2.01-6.98). Patients receiving PPI had longer ICU stays and later discharges. Acute kidney injury stage 2/3 was more common in patients with PPI until discharge (15.2 vs. 3.1%; p = 0.007), but was not statistically significant thereafter. Further differences in outcomes at 30 days did not reach significance. The data will aid pre- and post-procedural patient management and prevent adverse long-term outcomes.Clinical Trial: NCT03497611.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Valvuloplastia com Balão/efeitos adversos , Estimulação Cardíaca Artificial , Bloqueio Cardíaco/terapia , Frequência Cardíaca , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Europa (Continente) , Feminino , Bloqueio Cardíaco/diagnóstico , Bloqueio Cardíaco/etiologia , Bloqueio Cardíaco/fisiopatologia , Humanos , Masculino , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
5.
Catheter Cardiovasc Interv ; 93(2): 216-221, 2019 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-30232824

RESUMO

OBJECTIVES: To investigate the relative performance of treatment with a paclitaxel-eluting balloon (PEB) compared with an everolimus-eluting stent (EES) for in-stent restenosis (ISR) in patients with diabetes mellitus (DM). BACKGROUND: ISR remains a challenge in contemporary clinical practice, particularly in patients with DM. METHODS: In the multicenter randomized DARE trial, patients with BMS or DES ISR were randomized in a 1:1 fashion to treatment with a PEB or an EES. Patients underwent angiographic follow-up after 6 months. For the purpose of this analysis, the relative performance of PEB versus EES in diabetic patients was investigated. RESULTS: Of 278 patients enrolled in DARE, 88 (32%) had DM, of whom 46 were randomized to EES and 42 to PEB treatment. Of patients with DM, 48 (55%) had DES-ISR. Angiographic follow-up was available in 30 patients (72%) in the PEB group and 36 patients (78%) in the DES group. There were no differences in terms of 6-months minimal lumen diameter in diabetic patients treated with EES (1.46 ± 0.66 mm) versus PEB (1.78 ± 0.58 mm, P = 0.15). Adverse events at one year follow-up were similar in both groups, with Major Adverse Events (MAE, death, target vessel MI, or TVR) occurring in 17.4% in the EES group versus 11.9% in the PEB group, P = 0.44. CONCLUSIONS: In patients with ISR and DM, use of a PEB resulted in similar 6-months in-segment minimal lumen diameter and comparable rates of MAE. In-segment late loss at 6 months was significantly lower in the PEB arm. Although larger trials in DM patients with ISR are necessary, PEB is a promising treatment option obviating the need for additional stent implantation.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Cateteres Cardíacos , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Doença da Artéria Coronariana/terapia , Reestenose Coronária/terapia , Diabetes Mellitus , Stents Farmacológicos , Everolimo/administração & dosagem , Paclitaxel/administração & dosagem , Intervenção Coronária Percutânea/instrumentação , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Fármacos Cardiovasculares/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Diabetes Mellitus/diagnóstico , Everolimo/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Países Baixos , Paclitaxel/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
6.
Catheter Cardiovasc Interv ; 93(4): E248-E254, 2019 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-30208263

RESUMO

OBJECTIVES: The aim of this study was to assess the predictive value of PMA measurement for mortality. BACKGROUND: Current surgical risk stratification have limited predictive value in the transcatheter aortic valve implantation (TAVI) population. In TAVI workup, a CT scan is routinely performed but body composition is not analyzed. Psoas muscle area (PMA) reflects a patient's global muscle mass and accordingly PMA might serve as a quantifiable frailty measure. METHODS: Multi-slice computed tomography scans (between 2010 and 2016) of 583 consecutive TAVI patients were reviewed. Patients were divided into equal sex-specific tertiles (low, mid, and high) according to an indexed PMA. Hazard ratios (HR) and their confidence intervals (CI) were determined for cardiac and all-cause mortality after TAVI. RESULTS: Low iPMA was associated with cardiac and all-cause mortality in females. One-year adjusted cardiac mortality HR in females for mid-iPMA and high-iPMA were 0.14 [95%CI, 0.05-0.45] and 0.40 [95%CI, 0.15-0.97], respectively. Similar effects were observed for 30-day and 2-years cardiac and all-cause mortality. In females, adding iPMA to surgical risk scores improved the predictive value for 1-year mortality. C-statistics changed from 0.63 [CI = 0.54-0.73] to 0.67 [CI: 0.58-0.75] for EuroSCORE II and from 0.67 [CI: 0.59-0.77] to 0.72 [CI: 0.63-0.80] for STS-PROM. CONCLUSIONS: Particularly in females, low iPMA is independently associated with an higher all-cause and cardiac mortality. Prospective studies should confirm whether PMA or other body composition parameters should be extracted automatically from CT-scans to include in clinical decision making and outcome prediction for TAVI.


Assuntos
Estenose da Valva Aórtica/cirurgia , Composição Corporal , Fragilidade/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Músculos Psoas/diagnóstico por imagem , Sarcopenia/diagnóstico por imagem , Substituição da Valva Aórtica Transcateter/mortalidade , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Feminino , Fragilidade/mortalidade , Fragilidade/fisiopatologia , Nível de Saúde , Humanos , Masculino , Valor Preditivo dos Testes , Músculos Psoas/fisiopatologia , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Sarcopenia/mortalidade , Sarcopenia/fisiopatologia , Fatores Sexuais , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
7.
J Invasive Cardiol ; 33(10): E823-E832, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34609327

RESUMO

OBJECTIVES: To analyze the effect of percutaneous coronary intervention (PCI) before transcatheter aortic valve replacement (TAVR) on all-cause and cardiovascular mortality after TAVR, differentiating between significant proximal lesions and the non-proximal (residual) lesions. METHODS: An institutional TAVR database was complemented with data on the extent of coronary artery disease (CAD), lesion location, lesion severity, and the location of PCI. Survival analysis was performed to investigate the impact on 6-month and 3-year mortality after TAVR in all patients and in subgroups of patients with significant proximal lesions (>70% diameter stenosis [DS], >50% DS in left main), the non-proximal residual lesions, and in a propensity score matched cohort. RESULTS: Among the 577 included patients, mean age was 83 years, 50% were female, and 31% had diabetes mellitus. Preprocedural PCI of unselected lesions was independently associated with increased 6-month mortality (hazard ratio, 2.2; 95% confidence interval, 1.0-4.6; P=.04), but selective PCI of significant proximal lesions did not have an association with higher mortality, nor did we find a significant effect of PCI on mortality in the propensity-matched cohort. CONCLUSION: Routine pre-TAVR PCI is not associated with mortality reduction in TAVR patients with coronary lesions in any segment or in patients with proximal coronary lesions. Despite the lack of a beneficial effect of routine pre-TAVR PCI, we cannot exclude a beneficial effect in a selection of patients with proximal lesions. Therefore, we strongly support the current clinical guidelines to only consider pre-TAVR PCI in proximal coronary lesions, while advocating a restrictive pre-TAVR PCI strategy.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia , Feminino , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
8.
J Am Heart Assoc ; 9(5): e015133, 2020 03 03.
Artigo em Inglês | MEDLINE | ID: mdl-32102615

RESUMO

Background As younger patients are being considered for transcatheter aortic valve implantation (TAVI), the assessment and treatment of concomitant coronary artery disease is taking on increased importance. Methods and Results Thirteen contemporary lower-risk patients with TAVI with severe aortic stenosis (AS) and moderate-severe coronary lesions were included. Patients underwent assessment of coronary hemodynamics in the presence of severe AS (pre-TAVI), in the absence of severe AS (immediately post-TAVI), and at longer-term follow-up (6 months post-TAVI). Fractional flow reserve decreased from 0.85 (0.76-0.88) pre-TAVI to 0.79 (0.74-0.83) post-TAVI, and then to 0.71 (0.65-0.77) at 6-month follow-up (P<0.001 for all comparisons). Conversely, instantaneous wave-free ratio was not significantly different: 0.82 (0.80-0.90) pre-TAVI, 0.83 (0.77-0.88) post-TAVI, and 0.83 (0.73-0.89) at 6 months (P=0.735). These changes are explained by the underlying coronary flow. Hyperemic whole-cycle coronary flow (fractional flow reserve flow) increased from 26.36 cm/s (23.82-31.82 cm/s) pre-TAVI to 30.78 cm/s (29.70-34.68 cm/s) post-TAVI (P=0.012), to 40.20 cm/s (32.14-50.00 cm/s) at 6-month follow-up (P<0.001 for both comparisons). Resting flow during the wave-free period of diastole was not significantly different: 25.48 cm/s (21.12-33.65 cm/s) pre-TAVI, 24.54 cm/s (20.74-27.88 cm/s) post-TAVI, and 25.89 cm/s (22.57-28.96 cm/s) at 6 months (P=0.500). Conclusions TAVI acutely improves whole-cycle hyperemic coronary flow, with ongoing sustained improvements at longer-term follow-up. This enhanced response to hyperemic stimuli appears to make fractional flow reserve assessment less suitable for patients with severe AS. Conversely, resting diastolic flow is not significantly influenced by the presence of severe AS. Resting indices of coronary stenosis severity, therefore, appear to be more appropriate for this patient population, although large-scale prospective randomized trials will be required to determine the role of coronary physiology in patients with severe AS.


Assuntos
Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Doença da Artéria Coronariana/fisiopatologia , Estenose Coronária/fisiopatologia , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/complicações , Doença da Artéria Coronariana/complicações , Circulação Coronária/fisiologia , Estenose Coronária/complicações , Feminino , Seguimentos , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Humanos , Masculino , Fatores de Tempo , Resultado do Tratamento , Resistência Vascular/fisiologia
9.
JACC Case Rep ; 1(2): 101-104, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34316759

RESUMO

This case report underlines the complexity of the transcatheter aortic valve replacement (TAVR) procedure where rare complications sometimes are inevitable, even in experienced hands. Supra-annular dislocation of the balloon-expandable prosthesis was caused by loss of capture of the temporary transvenous pacemaker lead and treated successfully by retracting it towards the abdominal aorta. (Level of Difficulty: Advanced.).

10.
Ned Tijdschr Geneeskd ; 1632019 10 24.
Artigo em Holandês | MEDLINE | ID: mdl-31682089

RESUMO

In recent years, transcatheter aortic valve implantation (TAVI) has evolved from a treatment for patients who are inoperable or at high risk of surgical complications, to an equivalent alternative to surgical valve replacement for almost all patients with symptomatic, severe aortic valve stenosis. In the Netherlands, the number of patients who undergo TAVI gradually increases, while outcomes after TAVI improve and complication rates decrease. Before TAVI can be considered as the preferred treatment for aortic valve stenosis, however, additional insight is needed in valve durability, selection criteria for patients who benefit most from TAVI, and treatment outcomes regarding quality of life.


Assuntos
Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter , Ensaios Clínicos como Assunto , Humanos , Países Baixos , Avaliação de Resultados da Assistência ao Paciente , Seleção de Pacientes , Qualidade de Vida , Substituição da Valva Aórtica Transcateter/tendências
11.
JACC Cardiovasc Interv ; 12(10): 911-920, 2019 05 27.
Artigo em Inglês | MEDLINE | ID: mdl-31122347

RESUMO

OBJECTIVES: This study aimed to compare differences in patient characteristics and clinical outcomes of nonagenarians undergoing transcatheter aortic valve replacement (TAVR) versus patients younger than 90 years of age and to test the predictive accuracy of the logistic EuroSCORE (European System for Cardiac Operative Risk Evaluation), the EuroSCORE II, and the STS-PROM (Society of Thoracic Surgeons Predicted Risk of Mortality) for mortality after TAVR in nonagenarians. BACKGROUND: The prevalence of severe aortic valve stenosis is increasing due to the rising life expectancy. However, there are limited data evaluating outcomes in patients older than 90 years of age. Moreover, the predictive accuracy of risk scores for mortality has not been evaluated in nonagenarian patients undergoing transfemoral TAVR. METHODS: The CENTER (Cerebrovascular EveNts in Patients Undergoing TranscathetER Aortic Valve Implantation) collaboration (N = 12,381) is an international collaboration consisting of 3 national registries, 6 local or multicenter registries, and 1 prospective clinical study, selected through a systematic online search. The primary endpoint of this study was the difference in 30-day all-cause mortality and stroke after TAVR in nonagenarians versus patients younger than 90 years of age. Secondary endpoints included differences in baseline characteristics, in-hospital outcomes, and the differences in predictive accuracy of the logistic EuroSCORE, the EuroSCORE II, and STS-PROM. RESULTS: A total of 882 nonagenarians and 11,499 patients younger than 90 years of age undergoing transfemoral TAVR between 2007 and 2018 were included. Nonagenarians had considerably fewer comorbidities than their counterparts. Nevertheless, rates of 30-day mortality (9.9% vs. 5.4%; relative risk [RR]: 1.8; 95% confidence interval [CI]: 1.4 to 2.3; p = 0.001), in-hospital stroke (3.0% vs. 1.9%; RR: 1.5; 95% CI: 1.0 to 2.3; p = 0.04), major or life-threatening bleeding (8.1% vs. 5.5%; RR: 1.6; 95% CI: 1.1 to 2.2; p = 0.004), and new-onset atrial fibrillation (7.9% vs. 5.2%; RR: 1.6; 95% CI: 1.1 to 2.2; p = 0.01) were higher in nonagenarians. The STS-PROM adequately estimated mortality in nonagenarians, with an observed-expected mortality ratio of 1.0. CONCLUSIONS: In this large, global, patient-level analysis, mortality after transfemoral TAVR was 2-fold higher in nonagenarians compared with patients younger than 90 years of age, despite the lower prevalence of baseline comorbidities. Moreover, nonagenarians had a higher risk of in-hospital stroke, major or life-threatening bleeding, and new-onset atrial fibrillation. The STS-PROM was the only surgical risk score that accurately predicted the risk of mortality in nonagenarians.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Cateterismo Periférico , Artéria Femoral , Substituição da Valva Aórtica Transcateter , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/mortalidade , Feminino , Hemodinâmica , Humanos , Masculino , Complicações Pós-Operatórias/etiologia , Punções , Ensaios Clínicos Controlados Aleatórios como Assunto , Recuperação de Função Fisiológica , Sistema de Registros , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Índices de Gravidade do Trauma , Resultado do Tratamento
12.
Circ Cardiovasc Interv ; 12(12): e008263, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31752515

RESUMO

BACKGROUND: Patients with severe aortic stenosis (AS) often have coronary artery disease. Both the aortic valve and the coronary disease influence the blood flow to the myocardium and its ability to respond to stress; leading to exertional symptoms. In this study, we aim to quantify the effect of severe AS on the coronary microcirculation and determine if this is influenced by any concomitant coronary disease. We then compare this to the effect of coronary stenoses on the coronary microcirculation. METHODS: Group 1: 55 patients with severe AS and intermediate coronary stenoses treated with transcatheter aortic valve implantation (TAVI) were included. Group 2: 85 patients with intermediate coronary stenoses and no AS treated with percutaneous coronary intervention were included. Coronary pressure and flow were measured at rest and during hyperemia in both groups, before and after TAVI (group 1) and before and after percutaneous coronary intervention (group 2). RESULTS: Microvascular resistance over the wave-free period of diastole increased significantly post-TAVI (pre-TAVI, 2.71±1.4 mm Hg·cm·s-1 versus post-TAVI 3.04±1.6 mm Hg·cm·s-1 [P=0.03]). Microvascular reserve over the wave-free period of diastole significantly improved post-TAVI (pre-TAVI 1.88±1.0 versus post-TAVI 2.09±0.8 [P=0.003]); this was independent of the severity of the underlying coronary stenosis. The change in microvascular resistance post-TAVI was equivalent to that produced by stenting a coronary lesion with an instantaneous wave-free ratio of ≤0.74. CONCLUSIONS: TAVI improves microcirculatory function regardless of the severity of underlying coronary disease. TAVI for severe AS produces a coronary hemodynamic improvement equivalent to the hemodynamic benefit of stenting coronary stenoses with instantaneous wave-free ratio values <0.74. Future trials of physiology-guided revascularization in severe AS may consider using this value to guide treatment of concomitant coronary artery disease.


Assuntos
Estenose da Valva Aórtica/diagnóstico , Valva Aórtica/fisiopatologia , Cateterismo Cardíaco , Doença da Artéria Coronariana/diagnóstico , Circulação Coronária , Estenose Coronária/diagnóstico , Vasos Coronários/fisiopatologia , Hemodinâmica , Microcirculação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Velocidade do Fluxo Sanguíneo , Doença da Artéria Coronariana/fisiopatologia , Doença da Artéria Coronariana/terapia , Estenose Coronária/fisiopatologia , Europa (Continente) , Feminino , Humanos , Masculino , Intervenção Coronária Percutânea , Valor Preditivo dos Testes , Recuperação de Função Fisiológica , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter , Resultado do Tratamento
13.
Trends Cardiovasc Med ; 28(6): 412-418, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29428159

RESUMO

Transcatheter aortic valve implantation (TAVI) in patients with aortic valve stenosis is associated with an improvement of clinical outcomes, quality of life, and self-sufficiency. The most feared TAVI-related complication is the occurrence of stroke. In order to reduce peri-procedural cerebral embolizations, diverse cerebral protection devices have been developed. These devices work though deflection or filtering of emboli, and are in different stages of testing. Silent cerebral infarctions identified by diffusion-weighted magnetic resonance imaging (DW-MRI) are used as surrogate primary outcomes, but the clinical significance is still unclear. This review provides a synopsis of the diverse cerebral protection devices and summarizes the current evidence on their efficacy during TAVI.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Dispositivos de Proteção Embólica , Embolia Intracraniana/prevenção & controle , Acidente Vascular Cerebral/prevenção & controle , Substituição da Valva Aórtica Transcateter/instrumentação , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Imagem de Difusão por Ressonância Magnética , Humanos , Embolia Intracraniana/diagnóstico por imagem , Embolia Intracraniana/etiologia , Desenho de Prótese , Fatores de Risco , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
14.
Am J Cardiol ; 121(12): 1581-1586, 2018 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-29627110

RESUMO

In patients who underwent transcatheter aortic valve implantation (TAVI), postoperative mortality risk is commonly assessed with risk scores such as the Society of Thoracic Surgeons-Postoperative Risk of Mortality (STS-PROM) and EuroSCORE II, in which age plays a dominant role. However, we reason that in the naturally selected oldest-old patients (nonagenarians), this may not be completely justified and that therefore age should play a minor role in decision-making. The objective of this study was to compare procedural outcome and mid-term mortality of transfemoral (TF)-TAVI patients aged ≥90 years with patients aged <90 years. In this single-center analysis of 599 prospectively acquired consecutive TF-TAVI patients between 2009 and 2017, we compared patients aged ≥90 (i.e., nonagenarians, n = 47) with patients aged <90 years (n = 552), using Kaplan-Meyer analysis and multivariate logistic regression. In the nonagenarians, we found more aortic regurgitation, moderate to severe paravalvular leakage, strokes and vascular complications, and less device success and bleeding complications compared with patients <90 years. Both groups showed similar symptomatic improvement. The predicted (STS-PROM) and actual procedural mortality were 8.033% and 2.1% (3.8×) and 4.868% and 1.8% (2.7×) for the nonagenarians and controls, respectively. Survival was not statistically different at the 1-, 2-, 3-, 4-, and 5-year mark. In conclusion, nonagenarians had similar symptomatic improvement and acceptable procedural outcome and mid-term survival to TF-TAVI patients aged <90 years. Thus, age is not a risk factor in predicting postoperative outcome and mortality and therefore should not be a reason to deny the oldest-old patient transfemoral TAVI.


Assuntos
Insuficiência da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/cirurgia , Hemorragia Pós-Operatória/epidemiologia , Acidente Vascular Cerebral/epidemiologia , Substituição da Valva Aórtica Transcateter , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Feminino , Mortalidade Hospitalar , Humanos , Modelos Logísticos , Masculino , Análise Multivariada , Razão de Chances , Complicações Pós-Operatórias/epidemiologia , Modelos de Riscos Proporcionais , Resultado do Tratamento
15.
Open Heart ; 5(2): e000879, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30275957

RESUMO

Objective: Transcatheter aortic valve implantation (TAVI) provides a significant symptom relief and mortality reduction in most patients; however, a substantial group of patients does not experience the same beneficial results according to physician-determined outcomes. Methods: Single-centre prospective design; the population comprises all consecutive patients undergoing TAVI in 2012-2017. TAVI futility was defined as the combined endpoint of either no symptomatic improvement or mortality at 1 year. We actively gathered telephone follow-up using a predefined questionnaire. Results: Guideline defined TAVI futility was present in 212/741 patients. Multivariate regression showed lower albumin and non-transfemoral approach to be predictive for futility. In addition to these, chronic obstructive pulmonary disease, lower estimated glomerular filtration rate, atrial fibrillation, low-flow-low-gradient aortic stenosis and lower Body Mass Index were predictive for 1-year mortality. Patients who showed symptomatic benefit estimated the percentage in which their symptoms were remedied higher than patients who did not (80% vs 60%, p<0.001). Guideline-defined TAVI futility occurs frequently, contrasting with patient-reported outcome measures (PROMs). The vast majority in both groups would again choose for TAVI treatment. Conclusion: Lower albumin and non-transfemoral access route were predictors for guideline-defined TAVI futility, defined as mortality within 1 year or no objective symptomatic improvement in New York Heart Association class. Futility according to this definition occurred frequently in this study, contrasting with much more positive PROMs. The majority of patients would undergo a TAVI again, underlining the patients' experienced value of TAVI and putting the definition of TAVI futility further on debate. In the near future, less-strict criteria for TAVI futility, that is, using a shorter warranted life expectancy and incorporating patients' perceived outcomes, should be used.

16.
Am J Cardiol ; 121(7): 856-861, 2018 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-29415808

RESUMO

Over the years increasing experience and technical device improvements in transcatheter aortic valve implantation (TAVI) have led to treatment of patients with lower surgical risks. Specifically for this population, device performance and longer term outcome are of great importance. In this single center, we performed a retrospective analysis of 515 consecutive patients with low- to intermediate surgical risk (STS-PROM ≤8), who underwent transfemoral TAVI between January 2009 and February 2017 with the SXT and ES3 prostheses, and we assessed procedural outcome and procedural and 3-year survival. Mean age (82 years in both groups, p = 0.344) and STS-PROM risk score (3.862 vs 3.992, p = 0.154) did not differ between the ES3 and SXT group. ES3-treated patients showed favorable procedural outcomes, with significantly higher device success (90% vs 73%, p <0.0001) and less paravalvular leakage (7% vs 13%, p <0.0001). Procedural mortality (0.87% vs 1.45%, p = 0.245) and the very low rate of permanent pacemaker implantations (7.4% vs 6.1%, p = 0.234) did not differ significantly. Three-year survival was 87% in the ES3 vs 80% in the SXT group (log-rank p = 0.385). In conclusion, we showed excellent survival and procedural outcomes in patients receiving a transfemoral TAVI with either the SAPIEN 3 or the SAPIEN XT device. The newer SAPIEN 3 even outperforms the SAPIEN XT in terms of less major bleeding complications, substantially higher device success rates, and less paravalvular leakage, with the permanent pacemaker implantation rate being very low in both groups. Survival curves show a nonsignificant trend toward better midterm survival in the ES3 group.


Assuntos
Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Complicações Pós-Operatórias/epidemiologia , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Marca-Passo Artificial , Hemorragia Pós-Operatória/epidemiologia , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Acidente Vascular Cerebral/epidemiologia , Taxa de Sobrevida , Resultado do Tratamento
17.
Am J Cardiol ; 121(10): 1231-1238, 2018 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-29703437

RESUMO

Vascular complications (VCs) after transfemoral transcatheter aortic valve implantation (TAVI) have always been reported to occur frequently. Studies addressing VCs have been conducted with older-generation prostheses. We aimed to evaluate the incidence, predictors, and impact of VCs after transfemoral TAVI with the balloon-expandable SAPIEN 3. We report a single-center retrospective analysis of 400 consecutive patients of a prospectively acquired cohort. All patients underwent transfemoral TAVI with SAPIEN 3 between January 2014 and December 2016. VC was defined according to the Valve Academic Research Consortium. In this cohort 83 patients had VCs (20.8%), 5.8% major and 15.0% minor. Sheath-to-iliofemoral artery ratio was the only predictor of major VCs (odds ratio 7.51, 95% confidence interval 1.61 to 34.95, p = 0.010). The area under the receiver-operator characteristic curve for sheath-to-iliofemoral artery ratio was 0.63 (poor accuracy). Thirty-day mortality rates were 17.4%, 1.7%, and 0.6% for major, minor, and no VCs, respectively (log-rank p ≤0.001). After adjustment, only major VCs were associated with 30-day mortality (adjusted hazard ratio 48.31, 95% confidence interval 7.80 to 299.24). Mortality from 30 days until 1 year did not differ between patients with and without VCs (log-rank p = 0.61). In conclusion we report that VCs remain an issue of transfemoral TAVI with the SAPIEN 3, and their prediction continues to be difficult, albeit the low-incidence, major VCs were associated with higher 30-day mortality. However, after these first 30 days, they were not of influence on survival anymore.


Assuntos
Estenose da Valva Aórtica/cirurgia , Complicações Pós-Operatórias/epidemiologia , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Dissecção Aórtica/epidemiologia , Falso Aneurisma/epidemiologia , Angiografia por Tomografia Computadorizada , Falha de Equipamento/estatística & dados numéricos , Feminino , Artéria Femoral/anatomia & histologia , Próteses Valvulares Cardíacas , Ventrículos do Coração/lesões , Hematoma/epidemiologia , Humanos , Artéria Ilíaca/anatomia & histologia , Incidência , Modelos Logísticos , Masculino , Mortalidade , Tamanho do Órgão , Hemorragia Pós-Operatória/epidemiologia , Desenho de Prótese , Curva ROC , Estudos Retrospectivos , Fatores de Risco , Dispositivos de Oclusão Vascular
18.
JACC Cardiovasc Interv ; 11(3): 275-283, 2018 02 12.
Artigo em Inglês | MEDLINE | ID: mdl-29413242

RESUMO

OBJECTIVES: The authors sought to evaluate the relative performance of a drug-eluting balloon (DEB) and a drug-eluting stent (DES) in patients with any (bare-metal or drug-eluting stent) in-stent restenosis (ISR). BACKGROUND: The treatment of ISR remains challenging in contemporary clinical practice. METHODS: In a multicenter randomized noninferiority trial, patients with any ISR were randomly allocated in a 1:1 fashion to treatment with a DEB (SeQuent Please paclitaxel-eluting balloon, B. Braun Melsungen, Melsungen, Germany), or a DES (XIENCE everolimus-eluting stent, Abbott Vascular, Santa Clara, California). The primary endpoint was noninferiority in terms of in-segment minimal lumen diameter (MLD) at 6-month angiographic follow-up. Secondary endpoints included angiographic parameters at 6 months and clinical follow-up up to 12 months. RESULTS: A total of 278 patients, of whom 56% had DES-ISR, were randomized at 8 sites to treatment with DEB (n = 141) or DES (n = 137). As compared with DEB, DES was associated with larger MLD and lower % stenosis immediately post-procedure (1.84 ± 0.46 vs. 1.72 ± 0.35; p = 0.018; and 26 ± 10% vs. 30 ± 10%; p = 0.03). Angiographic follow up was completed at 196 ± 53 days in 79% of patients. With respect to the primary endpoint of in-segment MLD at 6 months, DEB was noninferior to DES (DEB 1.71 ± 0.51 mm vs. DES 1.74 ± 0.61 mm; p for noninferiority <0.0001). Target vessel revascularization at 12-month follow-up was similar in both groups (DES 7.1% vs. DEB 8.8%; p = 0.65). CONCLUSIONS: In patients with ISR, treatment with DEB was noninferior compared with DES in terms of 6-month MLD. There were no differences in clinical endpoints, including target vessel revascularization up to 12 months. Therefore, use of a DEB is an attractive treatment option for in-stent restenosis, withholding the need for additional stent implantation.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Cateteres Cardíacos , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Reestenose Coronária/cirurgia , Stents Farmacológicos , Everolimo/administração & dosagem , Paclitaxel/administração & dosagem , Intervenção Coronária Percutânea/instrumentação , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Fármacos Cardiovasculares/efeitos adversos , Angiografia Coronária , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Everolimo/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Países Baixos , Paclitaxel/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Reoperação , Fatores de Tempo , Resultado do Tratamento
19.
JACC Clin Electrophysiol ; 3(12): 1400-1408, 2017 12 11.
Artigo em Inglês | MEDLINE | ID: mdl-29759671

RESUMO

OBJECTIVES: This study evaluated the yield of ajmaline testing and assessed the occurrence of confounding responses in a large cohort of families with unexplained cardiac arrest (UCA) or sudden unexplained death (SUD). BACKGROUND: Ajmaline testing to diagnose Brugada syndrome (BrS) is routinely used in the evaluation of SUD and UCA, but its yield, limitations, and appropriate dosing have not been studied in a large cohort. METHODS: We assessed ajmaline test response and genetic testing results in 637 individuals from 482 families who underwent ajmaline testing for SUD or UCA. RESULTS: Overall, 89 individuals (14%) from 88 families (18%) had a positive ajmaline test result. SCN5A mutations were identified in 9 of 86 ajmaline-positive cases (10%). SCN5A mutation carriers had positive test results at significantly lower ajmaline doses than noncarriers (0.75 [range: 0.64 to 0.98] mg/kg vs. 1.03 [range: 0.95 to 1.14] mg/kg, respectively; p < 0.01). In 7 of 88 families (8%), it was concluded that the positive ajmaline response was a confounder, either in the presence of an alternative genetic diagnosis accounting for UCA/SUD (5 cases) or noncosegregation of positive ajmaline response and arrhythmia (2 cases). The rate of confounding responses was significantly higher in positive ajmaline responses obtained at >1 mg/kg than in those obtained at ≤1 mg/kg (7 of 48 vs. 0 of 41 individuals; Fisher's exact test: p = 0.014). CONCLUSIONS: In line with previous, smaller studies, a positive ajmaline response was observed in a large proportion of UCA/SUD families. Importantly, our data emphasize the potential for confounding possibly false-positive ajmaline responses in this population, particularly at high doses, which could possibly lead to a misdiagnosis. Clinicians should consider all alternative causes in UCA/SUD and avoid ajmaline doses >1 mg/kg.


Assuntos
Ajmalina/administração & dosagem , Síndrome de Brugada/diagnóstico , Morte Súbita Cardíaca/etiologia , Parada Cardíaca/etiologia , Administração Intravenosa , Adulto , Síndrome de Brugada/epidemiologia , Síndrome de Brugada/genética , Morte Súbita Cardíaca/epidemiologia , Erros de Diagnóstico/prevenção & controle , Feminino , Testes Genéticos/métodos , Parada Cardíaca/epidemiologia , Heterozigoto , Humanos , Masculino , Pessoa de Meia-Idade , Mutação , Canal de Sódio Disparado por Voltagem NAV1.5/genética , Linhagem , Fenótipo , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/epidemiologia , Fibrilação Ventricular/fisiopatologia , Bloqueadores do Canal de Sódio Disparado por Voltagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA