Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Sex Transm Dis ; 45(1): 42-48, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28876298

RESUMO

BACKGROUND: Testing for high-risk human papillomavirus (HPV) infection using mailed, self-collected samples is a promising approach to increase screening in women who do not attend clinic screening at recommended intervals. METHODS: To assess this intervention among high-risk women in the United States, 429 women without a Papanicolaou (Pap) test in 4 or more years (overdue by US guidelines) were recruited from the general population. Participants aged 30 to 65 years were mailed a kit to self-collect a cervicovaginal sample at home, return the sample by mail, and receive HPV results by telephone, with referral to follow-up cytological Pap testing at a local clinic. Cervicovaginal self-samples were collected with a Viba brush, stored in Scope mouthwash, and tested by Hybrid Capture 2. Data were collected in 2010 to 2011 and analyzed in 2017. RESULTS: Two-thirds (64%) of participants returned a self-collected sample, of whom 15% tested HPV DNA positive. Human papillomavirus self-test-positive women reported higher rates of follow-up Pap tests (82%) than did those with self-test negative results (51%). No demographic differences were found in self-test return rate or HPV positivity. High acceptability was reported in participant surveys: most women (81%) had "mostly positive" overall thoughts about the self-test, and most reported being comfortable receiving the kit in the mail (99%), returning their self-collected sample by mail (82%), and receiving their test results by telephone (97%). CONCLUSIONS: Conducting HPV self-testing through population-based recruitment, mailed kit delivery and return by mail, and results delivery by telephone has the potential to reach a broad segment of US underscreened women.


Assuntos
Detecção Precoce de Câncer/métodos , Testes de DNA para Papilomavírus Humano , Programas de Rastreamento/métodos , Teste de Papanicolaou , Papillomaviridae/isolamento & purificação , Infecções por Papillomavirus/diagnóstico , Neoplasias do Colo do Útero/virologia , Adulto , Estudos de Viabilidade , Feminino , Humanos , Pessoa de Meia-Idade , Aceitação pelo Paciente de Cuidados de Saúde/estatística & dados numéricos , Cooperação do Paciente/estatística & dados numéricos , Encaminhamento e Consulta , Autocuidado , Manejo de Espécimes , Estados Unidos/epidemiologia , Neoplasias do Colo do Útero/prevenção & controle , Esfregaço Vaginal
2.
J Clin Microbiol ; 54(8): 2008-13, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27194690

RESUMO

Herpes simplex virus (HSV) causes acute and relapsing symptoms characterized by ulcerative lesions. Laboratory diagnosis of HSV in cutaneous or mucocutaneous lesions has historically been performed with the use of viral cell culture systems; however, these tests are laborious and suffer decreased sensitivity for advanced-stage lesions. The recent availability of FDA-cleared moderately complex assays has resulted in the increased use of molecular diagnostics for the routine detection of HSV in superficial swab specimens. We performed a clinical evaluation of the recently FDA-cleared illumigene HSV 1&2 loop-mediated isothermal amplification (LAMP) assay (Meridian Bioscience, Cincinnati OH) for the detection and differentiation of HSV-1 and HSV-2 in cutaneous and mucocutaneous swab specimens. A total of 1,153 clinical swab specimens were collected and tested at 7 different clinical centers. Each specimen was tested for the presence of HSV-1 and HSV-2 using the illumigene assay, and results were compared to those of the enzyme-linked virus-inducible system (ELVIS) as the reference method. Overall, the illumigene assay demonstrated a sensitivity and specificity of 94.8% and 95.5%, respectively, for the detection of HSV-1. Detection of HSV-2 was similar, with a sensitivity of 98.9% and a specificity of 95.5%. Discrepant analysis was performed using an alternative molecular test (AmpliVue HSV1+2 assay; Quidel Molecular, San Diego, CA) on 91/99 specimens that were recorded as false positive (FP) or false negative (FN) compared to the reference method. In total, 57/78 (73%) FP and 9/13 (69%) FN illumigene results were supported by the AmpliVue result. The illumigene HSV 1&2 assay demonstrated high sensitivity and specificity to detect and differentiate HSV in clinical specimens and identified 57 additional specimens that were positive for HSV compared to culture. The use of LAMP eliminates the need for the cycling of temperatures and provides results in less than 60 min, with approximately 2 min of hands-on time per specimen.


Assuntos
Herpes Genital/diagnóstico , Herpes Simples/diagnóstico , Herpesvirus Humano 1/isolamento & purificação , Herpesvirus Humano 2/isolamento & purificação , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Amplificação de Ácido Nucleico/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Adulto Jovem
3.
J Med Virol ; 88(8): 1427-37, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-26815906

RESUMO

The lymphotropic herpesviruses, cytomegalovirus (CMV), Epstein-Barr virus (EBV), and human herpesvirus 6B (HHV-6B) can reactivate and cause disease in organ transplant recipients; the contributions of HHV-6A and HHV-7 to disease are less certain. Less is known about their pathogenic roles in children undergoing treatment for malignancies. Children with newly diagnosed cancer were followed for 24 months. Clinical information and blood samples were collected during routine visits and during acute visits for fever or possible viral infections. Lymphotropic herpesvirus DNA in blood was measured by polymerase chain reaction (PCR). Although HHV-6B DNA was detected at least once in about half of the patients; the other viruses were seldom detected. There was no association between HHV-6B detection and individual acute clinical events, however, HHV-6B detection was more common in children who experienced more frequent acute clinical events. In children being treated for various malignancies, HHV-6B detection was common, but was not associated with individual events of acute illness. Thus, if HHV-6B is not assessed longitudinally, clinical events may be misattributed to the virus. The elevated frequency of detection of HHV-6B in sicker children is consistent with prior reports of its detection during apparently unrelated acute clinical events. J. Med. Virol. 88:1427-1437, 2016. © 2016 Wiley Periodicals, Inc.


Assuntos
Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos/virologia , Herpesvirus Humano 6/isolamento & purificação , Neoplasias/complicações , Neoplasias/tratamento farmacológico , Infecções por Roseolovirus/virologia , Doença Aguda , Adolescente , Adulto , Criança , Pré-Escolar , Estudos de Coortes , DNA Viral/sangue , Tratamento Farmacológico , Feminino , Herpesvirus Humano 6/genética , Herpesvirus Humano 7/genética , Herpesvirus Humano 7/isolamento & purificação , Humanos , Lactente , Estudos Longitudinais , Masculino , Neoplasias/virologia , Reação em Cadeia da Polimerase , Infecções por Roseolovirus/diagnóstico , Infecções por Roseolovirus/etiologia , Carga Viral , Adulto Jovem
4.
J Clin Microbiol ; 53(11): 3474-7, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26292304

RESUMO

The goal of this retrospective study was to evaluate the performance of different diagnostic tests for Legionnaires' disease in a clinical setting where Legionella pneumophila PCR had been introduced. Electronic medical records at the Cleveland Clinic were searched for Legionella urinary antigen (UAG), culture, and PCR tests ordered from March 2010 through December 2013. For cases where two or more test methods were performed and at least one was positive, the medical record was reviewed for relevant clinical and epidemiologic factors. Excluding repeat testing on a given patient, 19,912 tests were ordered (12,569 UAG, 3,747 cultures, and 3,596 PCR) with 378 positive results. The positivity rate for each method was 0.4% for culture, 0.8% for PCR, and 2.7% for UAG. For 37 patients, at least two test methods were performed with at least one positive result: 10 (27%) cases were positive by all three methods, 16 (43%) were positive by two methods, and 11 (30%) were positive by one method only. For the 32 patients with medical records available, clinical presentation was consistent with proven or probable Legionella infection in 84% of the cases. For those cases, the sensitivities of culture, PCR, and UAG were 50%, 92%, and 96%, respectively. The specificities were 100% for culture and 99.9% for PCR and UAG.


Assuntos
Antígenos de Bactérias/urina , Testes Diagnósticos de Rotina/métodos , Testes Imunológicos/métodos , Doença dos Legionários/diagnóstico , Reação em Cadeia da Polimerase/métodos , Adulto , Idoso , Antígenos de Bactérias/imunologia , Feminino , Humanos , Legionella pneumophila/genética , Legionella pneumophila/imunologia , Doença dos Legionários/microbiologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
5.
J Clin Microbiol ; 53(12): 3922-5, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26468497

RESUMO

The AmpliVue HSV 1+2 assay was compared to the ELVIS HSV ID and D(3) Typing Culture System for the qualitative detection and differentiation of herpes simplex virus 1 (HSV-1) and HSV-2 DNA in 1,351 cutaneous and mucocutaneous specimens. Compared to ELVIS, AmpliVue had sensitivities of 95.7 and 97.6% for detecting HSV-1 and HSV-2, respectively. Following arbitration of discordant results by an independent molecular method, the AmpliVue assay had a resolved sensitivity and specificity of 99.2 and 99.7%, respectively, for both HSV-1 and HSV-2, whereas ELVIS had a resolved sensitivity of 87.1% for HSV-1 and 84.5% for HSV-2.


Assuntos
Herpes Simples/diagnóstico , Herpesvirus Humano 1/isolamento & purificação , Herpesvirus Humano 2/isolamento & purificação , Técnicas de Diagnóstico Molecular/métodos , Mucosa/virologia , Pele/virologia , Cultura de Vírus/métodos , Herpes Simples/virologia , Humanos , Sensibilidade e Especificidade
6.
Clin Transplant ; 28(12): 1416-23, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25303316

RESUMO

BACKGROUND: Infections with cytomegalovirus (CMV) and Epstein-Barr virus (EBV) remain important in solid organ transplantation. Quantitative viral nucleic acid testing is a major advance to patient management. These assays are limited by a lack of standardization, resulting in viral load measurements that differ among clinical laboratories. The variability in viral load measurements makes interpretation of multicenter clinical trials data difficult. This study compares the current practices in CMV and EBV viral load testing at four large transplant centers participating in multicenter Clinical Trials in Organ Transplantation and the Clinical Trials in Organ Transplantation in Children (CTOT and CTOTC). METHODS: Viral load testing was performed on well-defined viral preparations according to standard operating procedures at each site. RESULTS: Among centers, CMV viral load testing was accurate compared to WHO International Standards and within acceptable variation for this testing method. Epstein-Barr virus viral load data were more variable and less accurate despite the use of international standards. CONCLUSIONS: These data suggest that comparison of CMV, but not EBV, viral load measurements at these sites is possible using current assays and control standards. Standardization of these assays is facilitated using the WHO International Standards and will allow comparison of viral load results among transplant centers. Assay standardization must be performed prior to initiation of multicenter trials.


Assuntos
Infecções por Citomegalovirus/virologia , DNA Viral/sangue , Infecções por Vírus Epstein-Barr/virologia , Laboratórios/normas , Reação em Cadeia da Polimerase/normas , Carga Viral/métodos , Citomegalovirus/genética , Citomegalovirus/isolamento & purificação , Infecções por Citomegalovirus/diagnóstico , DNA Viral/genética , Infecções por Vírus Epstein-Barr/diagnóstico , Herpesvirus Humano 4/genética , Herpesvirus Humano 4/isolamento & purificação , Humanos , Agências Internacionais , Transplante de Órgãos , Kit de Reagentes para Diagnóstico , Padrões de Referência
7.
Clin Infect Dis ; 56(6): 817-24, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23196955

RESUMO

BACKGROUND: Cytomegalovirus (CMV) disease remains an important problem in solid-organ transplant recipients, with the greatest risk among donor CMV-seropositive, recipient-seronegative (D(+)/R(-)) patients. CMV-specific cell-mediated immunity may be able to predict which patients will develop CMV disease. METHODS: We prospectively included D(+)/R(-) patients who received antiviral prophylaxis. We used the Quantiferon-CMV assay to measure interferon-γ levels following in vitro stimulation with CMV antigens. The test was performed at the end of prophylaxis and 1 and 2 months later. The primary outcome was the incidence of CMV disease at 12 months after transplant. We calculated positive and negative predictive values of the assay for protection from CMV disease. RESULTS: Overall, 28 of 127 (22%) patients developed CMV disease. Of 124 evaluable patients, 31 (25%) had a positive result, 81 (65.3%) had a negative result, and 12 (9.7%) had an indeterminate result (negative mitogen and CMV antigen) with the Quantiferon-CMV assay. At 12 months, patients with a positive result had a subsequent lower incidence of CMV disease than patients with a negative and an indeterminate result (6.4% vs 22.2% vs 58.3%, respectively; P < .001). Positive and negative predictive values of the assay for protection from CMV disease were 0.90 (95% confidence interval [CI], .74-.98) and 0.27 (95% CI, .18-.37), respectively. CONCLUSIONS: This assay may be useful to predict if patients are at low, intermediate, or high risk for the development of subsequent CMV disease after prophylaxis. CLINICAL TRIALS REGISTRATION: NCT00817908.


Assuntos
Infecções por Citomegalovirus/imunologia , Imunidade Celular , Transplantes/efeitos adversos , Adulto , Idoso , Antivirais/uso terapêutico , Quimioprevenção/métodos , Estudos de Coortes , Feminino , Humanos , Hospedeiro Imunocomprometido , Imunossupressores/efeitos adversos , Testes de Liberação de Interferon-gama , Leucócitos Mononucleares/imunologia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Medição de Risco
8.
J Clin Microbiol ; 49(8): 2854-8, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21697326

RESUMO

The performance characteristics of four different assays for hepatitis B virus (HBV) quantification were assessed: the Abbott RealTime HBV IUO, the Roche Cobas AmpliPrep/Cobas TaqMan HBV test, the Roche Cobas TaqMan HBV test with HighPure system, and the Qiagen artus HBV TM ASR. Limit of detection (LOD), linear range, reproducibility, and agreement were determined using a serially diluted plasma sample from a single chronically infected subject. Each assay was tested by at least three laboratories. The LOD of the RealTime and two TaqMan assays was approximately 1.0 log(10) IU/ml; for artus HBV (which used the lowest volume of extracted DNA), it was approximately 1.5 log(10) IU/ml. The linear range spanned 1.0 to at least 7.0 log(10) IU/ml for all assays. Median values were consistently lowest for artus HBV and highest for Cobas AmpliPrep/Cobas TaqMan HBV. Assays incorporating automated nucleic acid extraction were the most reproducible; however, the overall variability was minor since the standard deviations for the means of all tested concentrations were ≤0.32 log(10) IU/ml for all assays. False-positive results were observed with all assays; the highest rates occurred with tests using manual nucleic acid extraction. The performance characteristics of these assays suggest that they are useful for management and therapeutic monitoring of chronic HBV infection.


Assuntos
DNA Viral/isolamento & purificação , Vírus da Hepatite B/isolamento & purificação , Hepatite B/virologia , Reação em Cadeia da Polimerase em Tempo Real/métodos , Carga Viral/métodos , DNA Viral/genética , Vírus da Hepatite B/genética , Humanos , Plasma/virologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
10.
J Clin Microbiol ; 48(7): 2337-43, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20463154

RESUMO

This multicenter study evaluated the clinical performance of the 3M Rapid Detection RSV test (3MRSV) compared to a composite reference standard of R-Mix culture and direct specimen immunofluorescence for detection of respiratory syncytial virus (RSV). The performance of the BinaxNOW RSV test was also evaluated using this reference standard. In a secondary analysis, discordant results were arbitrated using the Gen-Probe/Prodesse ProFlu+ reverse transcription-PCR (RT-PCR) assay. Subjects were stratified into three groups as follows: group 1 (G1), all ages; G2, subjects <22 years old (FDA-cleared ages for 3MRSV testing); and G3, subjects <5 years old (FDA-cleared ages for BinaxNOW RSV testing). A total of 1,306 specimens (G1, n = 1,306; G2, n = 1,140; G3, n = 953) from subjects of all ages presenting with respiratory symptoms met study criteria for analysis. Sensitivities, specificities, positive predictive values, and negative predictive values of 3MRSV for G1 were 86.5%, 95.8%, 91.4%, and 93.2%, respectively, and those for G2 were 87.3%, 95.6%, 92.4%, and 92.5%, respectively. For those samples analyzed by both 3MRSV and BinaxNOW, the 3MRSV was more sensitive (G1, 86.3%; G2, 87.2%; and G3, 89.9%) than was BinaxNOW (G1, 70.84%; G2, 72.0%; and G3, 72.4%) (P < 0.05). Specificities for RSV detection from nasopharyngeal (NP) aspirates and NP swabs for all groups were comparable for 3MRSV and BinaxNOW, but 3MRSV was less specific than BinaxNOW when nasal washes/aspirates were tested (P < 0.05). The 3MRSV assay performed well for the detection of RSV, and the overall assay performance was superior to that of BinaxNOW. The 3MRSV reader eliminated user misinterpretation and provided test result and quality control documentation.


Assuntos
Antígenos Virais/análise , Imunoensaio/métodos , Infecções por Vírus Respiratório Sincicial/diagnóstico , Vírus Sinciciais Respiratórios/isolamento & purificação , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Secreções Corporais/virologia , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Pulmão/virologia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Kit de Reagentes para Diagnóstico/virologia , Estatísticas não Paramétricas , Fatores de Tempo
11.
Am J Clin Pathol ; 151(1): 122-126, 2019 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-30239569

RESUMO

Objectives: To compare multiplex nucleic acid amplification tests (NAATs) that detect and differentiate herpes simplex virus (HSV) and varicella-zoster virus (VZV) with traditional virologic assays. Methods: The HSV ELVIS Test System (Quidel, San Diego, CA) and/or Light Diagnostics VZV direct fluorescent antibody (DFA) kit (Millipore Sigma, Billerica, MA), as well as an ARIES HSV 1&2/VZV assay (Luminex, Austin, TX) and the Solana HSV1 + 2/VZV Assay (Quidel), were performed on non-cerebrospinal fluid specimens. Results: The sensitivities/specificities for the ELVIS, Aries, and Solana assays for HSV were 71.1%/93.2%, 94.9%/93.2%, and 94.7%/100%, respectively. The sensitivities/specificities for the DFA, Aries, and Solana assays for VZV were 71.4%/100%, 100%/96.0%, and 95.3%/100%, respectively. HSV and VZV were detected but clinically unsuspected in 5.4% and 4.2% of the specimens, respectively. Conclusions: Both NAAT assays were comparable and more sensitive than traditional methods. The recovery of unsuspected HSV and VZV from clinical specimens supports the implementation of a combined HSV/VZV assay.


Assuntos
Herpesvirus Humano 2/isolamento & purificação , Herpesvirus Humano 3/isolamento & purificação , Simplexvirus/isolamento & purificação , Técnica Direta de Fluorescência para Anticorpo , Herpesvirus Humano 2/genética , Herpesvirus Humano 3/genética , Humanos , Reação em Cadeia da Polimerase Multiplex , Sensibilidade e Especificidade , Simplexvirus/genética , Infecção pelo Vírus da Varicela-Zoster
12.
Emerg Infect Dis ; 14(4): 579-85, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18394275

RESUMO

We conducted a cross-sectional study of beta-herpesviruses in febrile pediatric oncology patients (n = 30), with a reference group of febrile pediatric solid-organ transplant recipients (n = 9). One (3.3%) of 30 cancer patients and 3 (33%) of 9 organ recipients were PCR positive for cytomegalovirus. Four (13%) of 30 cancer patients and 3 (33%) of 9 transplant recipients had human herpesvirus 6B (HHV-6B) DNAemia, which was more common within 6 months of initiation of immune suppression (4 of 16 vs. 0 of 14 cancer patients; p = 0.050). HHV-6A and HHV-7 were not detected. No other cause was identified in children with HHV-6B or cytomegalovirus DNAemia. One HHV-6B-positive cancer patient had febrile disease with concomitant hepatitis. Other HHV-6B-positive children had mild "viral" illnesses, as did a child with primary cytomegalovirus infection. Cytomegalovirus and HHV-6B should be included in the differential diagnosis of febrile disease in children with cancer.


Assuntos
Betaherpesvirinae/isolamento & purificação , Infecções por Herpesviridae/complicações , Infecções por Herpesviridae/virologia , Hospedeiro Imunocomprometido , Neoplasias/complicações , Adolescente , Adulto , Criança , Pré-Escolar , Estudos Transversais , Feminino , Humanos , Lactente , Masculino , Transplante de Órgãos/efeitos adversos , Viremia/complicações , Viremia/virologia
13.
Leuk Res ; 32(2): 275-85, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17659339

RESUMO

The Hodgkin cells and Reed-Sternberg cells (HRS) of classical Hodgkin lymphoma (CHL) are derived from germinal center B cells. The pathogenesis of CHL is unclear but constitutive activation of NFkappaB may contribute. Proteasome inhibition aimed at inhibiting NFkappaB has been shown to result in apoptosis in HRS cells. Here we investigated the effects of bortezomib, a proteasome inhibitor, in HRS cells with a combination of functional assays and gene expression profiling (GEP). Exposure of KMH2 and L428 cells to bortezomib resulted in inhibition of proliferation and induction of apoptosis. Gene expression analysis of KMH2 cells by oligonucleotide cDNA microarrays showed that a limited set of genes were differentially expressed involving several key cellular pathways including cell cycle and apoptosis. Among them, the caspase 8 inhibitor cFLIP was down-regulated and confirmed by Q-PCR. Given the evidence that cFLIP in HRS cells contribute to cells' insensitive to death receptor-mediated apoptosis, we combined bortezomib and TRAIL. This combination caused further down-regulation of cFLIP protein and increased apoptosis in CHL cells demonstrated by PARP p85 immunohistochemistry and immunoblotting. Such apoptotic effects were inhibited by caspase inhibitor z-VAD-FMK, confirming the pro-apoptotic effects of bortezomib and TRAIL are caspase-dependent. Bortezomib has no detectable effect on expression of TRAIL receptor DR4/DR5 in these two cell lines. Tissue microarray analysis of primary Hodgkin lymphomas displayed that 82% cases (95/116) expressed cFLIP in Reed-Sternberg cells. The discovery of apoptotic pathways that can be manipulated by proteasome inhibition provides rationale for the combination of bortezomib and agents such as TRAIL in CHL treatment.


Assuntos
Antineoplásicos/farmacologia , Apoptose/efeitos dos fármacos , Ácidos Borônicos/farmacologia , Proteína Reguladora de Apoptosis Semelhante a CASP8 e FADD/efeitos dos fármacos , Expressão Gênica/efeitos dos fármacos , Doença de Hodgkin/metabolismo , Pirazinas/farmacologia , Apoptose/fisiologia , Western Blotting , Bortezomib , Proteína Reguladora de Apoptosis Semelhante a CASP8 e FADD/metabolismo , Caspases/metabolismo , Linhagem Celular Tumoral , Proliferação de Células/efeitos dos fármacos , Citometria de Fluxo , Perfilação da Expressão Gênica , Doença de Hodgkin/genética , Humanos , Imuno-Histoquímica , Análise de Sequência com Séries de Oligonucleotídeos , Células de Reed-Sternberg/efeitos dos fármacos , Células de Reed-Sternberg/metabolismo , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Ligante Indutor de Apoptose Relacionado a TNF/metabolismo , Ligante Indutor de Apoptose Relacionado a TNF/farmacologia , Análise Serial de Tecidos
14.
Diagn Microbiol Infect Dis ; 61(3): 351-3, 2008 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-18420370

RESUMO

Epstein-Barr virus serologic profiles were obtained from 618 patients using an automated platform, including the new BioPlex heterophile assay. When compared with 2 IgM viral capsid antigen (VCA) assays and a predicate heterophile assay, the BioPlex heterophile assay was more likely to be associated with serologic patterns of acute infection.


Assuntos
Anticorpos Heterófilos , Anticorpos Antivirais/sangue , Automação , Infecções por Vírus Epstein-Barr/diagnóstico , Herpesvirus Humano 4/isolamento & purificação , Imunoensaio/métodos , Adolescente , Adulto , Criança , Pré-Escolar , Herpesvirus Humano 4/imunologia , Humanos
16.
Inflamm Bowel Dis ; 24(4): 877-882, 2018 03 19.
Artigo em Inglês | MEDLINE | ID: mdl-29562270

RESUMO

Background: Tumor necrosis factor alpha (TNF-α) inhibitors are linked with increased risk of reactivation of active tuberculosis. The QuantiFERON-TB Gold In-Tube test is approved for screening latent tuberculosis infection in children and adults. There are limited data on the test performance in children on long-term treatment with TNF-α inhibitors. The objective of this study was to assess the proportion of indeterminate results for the QuantiFERON-TB Gold In-Tube in children with inflammatory bowel disease (IBD) on long-term infliximab treatment and to evaluate the range of interferon-γ responses to mitogen. Methods: A single-center prospective study of children 5 to 19 years of age with IBD on long-term infliximab treatment (>3 months). Each child was assessed for tuberculosis exposure risk and had blood drawn for the QuantiFERON-TB Gold In-Tube. Data on the range of interferon-γ responses and final QuantiFERON-TB Gold In-Tube test results were collected. Results: Ninety-three children were included, with a median age of 16 years. The median total duration of infliximab therapy was 34 months (range, 3-119 months). The QuantiFERON-TB Gold In-Tube was indeterminate in 1 patient (1.1%), positive in 2 patients, and negative in 90 patients. The maximum interferon-γ response to mitogen (10 IU/mL) was observed in 82 patients (88%), with only 1 patient having an inadequate response. The proportion of indeterminate results was significantly lower than the prospectively hypothesized rate of 8%, based on prior studies in nonimmunosuppressed patients (P = 0.004). Conclusions: Pediatric patients with IBD on long-term treatment with infliximab had an adequate interferon-γ response to mitogen and a low indeterminate rate when assessed with the QuantiFERON-TB Gold In-Tube test. This study demonstrates a robust interferon gamma response to phytohemagglutinin stimulation in a pediatric population on long-term therapy with infliximab. The QuantiFERON-TB Gold In-Tube test may therefore be useful as a periodic screening tactic for latent TB in children on long-term infliximab therapy.


Assuntos
Doenças Inflamatórias Intestinais/microbiologia , Infliximab/uso terapêutico , Testes de Liberação de Interferon-gama/estatística & dados numéricos , Tuberculose Latente/diagnóstico , Fator de Necrose Tumoral alfa/antagonistas & inibidores , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Doenças Inflamatórias Intestinais/tratamento farmacológico , Modelos Lineares , Masculino , Programas de Rastreamento , Estudos Prospectivos , Teste Tuberculínico/estatística & dados numéricos , Adulto Jovem
18.
PLoS One ; 12(2): e0168786, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28178290

RESUMO

Maternal viral infections can have pathological effects on the developing fetus which last long after birth. Recently, maternal-fetal transmission of respiratory syncytial virus (RSV) was shown to cause postnatal airway hyperreactivity (AHR) during primary early-life reinfection; however, the influence of prenatal exposure to RSV on offspring airway immunity and smooth muscle contractility during recurrent postnatal reinfections remains unknown. Therefore, we sought to determine whether maternal RSV infection impairs specific aspects of cell-mediated offspring immunity during early-life reinfections and the mechanisms leading to AHR. Red fluorescent protein-expressing recombinant RSV (rrRSV) was inoculated into pregnant rat dams at midterm, followed by primary and secondary postnatal rrRSV inoculations of their offspring at early-life time points. Pups and weanlings were tested for specific lower airway leukocyte populations by flow cytometry; serum cytokine/chemokine concentrations by multiplex ELISA and neurotrophins concentrations by standard ELISA; and ex vivo lower airway smooth muscle (ASM) contraction by physiological tissue bath. Pups born to RSV-infected mothers displayed elevated total CD3+ T cells largely lacking CD4+ and CD8+ surface expression after both primary and secondary postnatal rrRSV infection. Cytokine/chemokine analyses revealed reduced IFN-γ, IL-2, IL-12, IL-17A, IL-18, and TNF-α, as well as elevated nerve growth factor (NGF) expression. Prenatal exposure to RSV also increased ASM reactivity and contractility during early-life rrRSV infection compared to non-exposed controls. We conclude that maternal RSV infection can predispose offspring to postnatal lower airways dysfunction by altering immunity development, NGF signaling, and ASM contraction during early-life RSV reinfections.


Assuntos
Exposição Materna , Efeitos Tardios da Exposição Pré-Natal , Infecções por Vírus Respiratório Sincicial/imunologia , Infecções por Vírus Respiratório Sincicial/fisiopatologia , Vírus Sinciciais Respiratórios/imunologia , Animais , Biomarcadores , Hiper-Reatividade Brônquica/imunologia , Hiper-Reatividade Brônquica/metabolismo , Hiper-Reatividade Brônquica/fisiopatologia , Citocinas/metabolismo , Modelos Animais de Doenças , Feminino , Imunofenotipagem , Contração Muscular , Músculo Liso , Fenótipo , Gravidez , Ratos , Infecções por Vírus Respiratório Sincicial/virologia , Subpopulações de Linfócitos T/imunologia , Subpopulações de Linfócitos T/metabolismo
19.
Diagn Microbiol Infect Dis ; 89(1): 44-46, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28647065

RESUMO

The processing of specimens often occurs in a central processing area within laboratories. We demonstrated that plasma centrifuged in the central laboratory but allowed to remain within the primary tube following centrifugation was associated with spuriously elevated HIV viral loads compared with recentrifugation of the plasma just prior to testing.


Assuntos
Infecções por HIV/diagnóstico , Infecções por HIV/virologia , Manejo de Espécimes/métodos , Carga Viral/métodos , Humanos
20.
J Clin Virol ; 95: 5-9, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28818691

RESUMO

Point of Care Testing (POCT) provides the capability for rapid laboratory test results in patient care environments where a traditional clinical laboratory is not available. POCTs have shorter turn-around times (TATs), they may be performed by non-laboratory personnel, and the need for transport time is eliminated. The Food and Drug Administration (FDA) recently granted Clinical Laboratory Improvements Amendment (CLIA) waiver status to the cobas® Influenza A/B & RSV assay, a rapid, accurate point-of-care test for Influenza and respiratory syncytial virus (RSV) performed on the Liat® System. The performance characteristics of this test were determined though a multi-site study consisting of different point of care testing environments. Prospectively collected Nasopharyngeal (NP) swabs from 1361 patients seen at 8 primary care clinics and 4 emergency departments (EDs) and 295 retrospectively identified specimens were tested for Influenza A/B and RSV on the cobas® Liat® platform. Performance characteristics were determined through comparison to ProFlu+, a laboratory-based PCR test for Influenza A/B and RSV (reference test). Discordant specimens were adjudicated following bi-directional sequencing. The cobas® Influenza A/B and RSV assay showed sensitivities of 99.6%, 99.3%, and 96.8% for Influenza A, Influenza B, and RSV, respectively as determined from percent positive agreement (PPA) following comparison to the reference test. Sequencing confirmed cobas® Influenza A/B and RSV results in 49.2% of reference test discordant specimens, while crossing threshold data suggest increased sensitivity compared to the reference test. The cobas® Influenza A/B and RSV assay was found to be a rapid, sensitive POCT for the detection of these viruses, and provides laboratory-quality PCR-based diagnostic results in point of care settings.


Assuntos
Influenza Humana/diagnóstico , Influenza Humana/virologia , Técnicas de Diagnóstico Molecular/métodos , Sistemas Automatizados de Assistência Junto ao Leito , Infecções por Vírus Respiratório Sincicial/diagnóstico , Infecções por Vírus Respiratório Sincicial/virologia , Adolescente , Adulto , Idoso , Criança , Feminino , Humanos , Vírus da Influenza A/genética , Vírus da Influenza A/isolamento & purificação , Vírus da Influenza B/genética , Vírus da Influenza B/isolamento & purificação , Influenza Humana/classificação , Influenza Humana/epidemiologia , Masculino , Pessoa de Meia-Idade , Nasofaringe/virologia , Reação em Cadeia da Polimerase/métodos , Vírus Sincicial Respiratório Humano/genética , Estudos Retrospectivos , Sensibilidade e Especificidade , Estados Unidos/epidemiologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA