1.
Clin Chem Lab Med ; 61(7): 1280-1287, 2023 06 27.
Artigo em Inglês | MEDLINE | ID: mdl-37043622

RESUMO

OBJECTIVES: Monitoring quality indicators (QIs) is an important part of laboratory quality assurance (QA). Here, the Canadian Society of Clinical Chemists (CSCC) Point of Care Testing (POCT) and QI Special Interest Groups describe a process for establishing and monitoring QIs for POCT glucose testing. METHODS: Key, error prone steps in the POCT glucose testing process were collaboratively mapped out, followed by risk assessment for each step. Steps with the highest risk and ability to detect a non-conformance were chosen for follow-up. These were positive patient identification (PPID) and repeat of critically high glucose measurements. Participating sites were asked to submit aggregate data for these indicators from their site(s) for a one-month period. The PPID QI was also included as part of a national QI monitoring program for which fifty-seven sites submitted data. RESULTS: The percentage of POCT glucose tests performed without valid PPID ranged from 0-87%. Sites without Admission-Discharge-Transfer (ADT) connectivity to POCT meters were among those with the highest percentage of POCT glucose tests performed without valid PPID. The percentage repeated critically high glucose measurements ranged from 0-50%, indicating low compliance with this recommendation. A high rate of discordance was also noted when critically high POCT glucose measurements were repeated, demonstrating the importance of repeat testing prior to insulin administration. CONCLUSIONS: Here, a process for establishing these QIs is described, with preliminary data for two QIs chosen from this process. The findings demonstrate the importance of QIs for identification and comparative performance monitoring of non-conformances to improve POCT quality.


Assuntos
Glucose , Sistemas Automatizados de Assistência Junto ao Leito , Indicadores de Qualidade em Assistência à Saúde , Canadá , Opinião Pública , Glucose/química , Testes Imediatos , Humanos
2.
Perfusion ; 36(6): 610-619, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32885714

RESUMO

BACKGROUND: In cardiac surgery on cardiopulmonary bypass (CPB), heparin anticoagulation is monitored by point-of-care measurement of activated clotting time (ACT). The objective of this study was to compare four ACT systems in cardiac surgery in terms of their reproducibility, agreement and potential clinical impact at relevant medical decision points. METHODS: The study included 40 cardiac surgery patients. Samples were taken at five time points before (T1), after heparinization for CPB (T2, T3, T4), and after heparin reversal (T5). The reproducibility, correlation, and differences in ACT values were assessed with two devices from each of the four ACT systems: Instrumentation Laboratory Hemochron Elite (Hmch), Medtronic HMS Plus (HMS), Abbott i-STAT, and Helena Abrazo. Subrange analyses were performed for low ACT values (results from T1, T5) and high ACT values (results from T2, T3, T4). RESULTS: Within-system analysis showed strong linear correlation between paired measurements (R = 0.968-0.993). However, Hmch showed poorer reproducibility with highest proportion of values that exceed a difference of 10% and highest overall standard error of 74 seconds across the measurement range compared to that of the others (range 39-47 seconds, respectively). For inter-system comparison, using Hmch as reference, ACTs were strongly correlated as follows: HMS (R = 0.938), i-STAT (R = 0.911), and Abrazo (R = 0.911). Agreement analysis in the high ACT range showed HMS tended to have higher ACT values with +11% bias over Hmch, whereas i-STAT (-8% bias) and Abrazo (-13% bias) tended to underestimate. Post-protamine ACT results were dependent on device type where Hmch yielded highest post-protamine ACT (+13% higher than baseline) compared to -16% for HMS, -10% for iSTAT and 0% for Abrazo. CONCLUSIONS: Each device had individual reproducibility and biases, which may impact peri-operative heparin management. Careful validation must be undertaken when adopting a different method as decision limits would be affected. Clinicians should also be cautious using ACT as the only indicator for full heparin reversal.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Ponte Cardiopulmonar , Anticoagulantes , Heparina , Humanos , Reprodutibilidade dos Testes , Tempo de Coagulação do Sangue Total
3.
J Oncol Pharm Pract ; 24(3): 198-200, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29284355

RESUMO

Background Dysfunctional central venous catheter prohibits the administration of potential life-saving chemotherapy and the delivery of essential supportive care needs to patients. Sodium bicarbonate injection has been shown to impede against fibrin clot formation and prolong prothrombin time and thrombin clotting time. Sodium bicarbonate injection has been tried as a second-line agent with good results in a small number of patients (internal data not published) when alteplase failed. We assessed whether the pre-filled sodium bicarbonate injection in 5 mL syringes would not only preserve sterility and retain its pH and concentration but also amount to the potential cost savings for future use when stored in a refrigerated environment. Methodology Twelve pre-filled 5 mL syringes were prepared aseptically, of which four each were tested for pH, sodium bicarbonate injection concentration and sterility when stored in refrigerated temperature over a six-week period. A standard pH meter, enzymatic carbon dioxide analyzer, and a 14-day incubation for microbial detection were employed for this study. Results Sodium bicarbonate concentration measured in the form of carbon dioxide ranged from 923 mmol/L or (1846 mosol/L) to 1006 mmol/L or (2012 mosmol/L), and pH ranged from (7.88 to 8.05) were reported over the duration of the study period. The 14-day incubation period resulted in no microbial growth. Conclusion Our study results have indicated that the pH and sodium bicarbonate injection concentration values were stable and within range, comparable to those reported by the manufacturer within the study period. The contents of the subdivided sodium bicarbonate injection 5 mL syringes retained sterility over a 14-day incubation period.


Assuntos
Temperatura Baixa , Contaminação de Medicamentos/prevenção & controle , Bicarbonato de Sódio/normas , Seringas/normas , Composição de Medicamentos/normas , Estabilidade de Medicamentos , Humanos , Concentração de Íons de Hidrogênio , Bicarbonato de Sódio/química , Seringas/microbiologia , Fatores de Tempo
4.
Prostate ; 76(2): 235-42, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26768279

RESUMO

BACKGROUND: Androgen deprivation therapy (ADT) with luteinizing hormone releasing hormone (LHRH) agonists is an effective initial therapy for men with advanced prostate cancer. LHRH agonists are usually administered indefinitely at a fixed interval. METHODS: We recruited men with advanced prostate cancer who had been on fixed-schedule injections of an LHRH agonist for ≥1 year and had castrate serum testosterone [<1.75 nmol/l (approx. 50 ng/ml)]. Testosterone levels were measured at 6-week intervals and ADT was withheld until testosterone levels were no longer in the castrate range and then reinstituted. Time to reinstitution of ADT was the primary outcome and was analyzed by the Kaplan-Meier method; Cox regression was used to identify factors predicting delay in reinstitution of treatment. Influence on quality-of-life (QoL) was evaluated by the Expanded Prostate Index Composite (EPIC). RESULTS: Forty-six evaluable men who had received LHRH agonist injections every 12 weeks were recruited. Median time to testosterone recovery (defined as testosterone outside the defined castrate level) after previous injection was >1 year. In univariable analysis, lower baseline testosterone [≤1 vs. >1 nmol/l (approx. 30 ng/dl)] and longer time on ADT (>5 vs. ≤5 years) predicted for prolonged time to testosterone recovery, but only lower baseline testosterone remained significant in multivariable analysis (Hazard Ratio = 5.2, P = 0.03). Overall EPIC scores remained stable but improvement from baseline was observed in the hormonal domain (P = 0.002). Median per-patient saving in cost was approximately USD 3,100 (1,050-6,200). CONCLUSIONS: Testosterone-guided ADT reduces exposure to LHRH agonists, with reduction in cost and improvement in some symptoms from ADT. Testosterone-guided ADT should be considered an alternative to fixed schedule treatment by physicians and policy makers.


Assuntos
Antagonistas de Androgênios/administração & dosagem , Antineoplásicos Hormonais/administração & dosagem , Gerenciamento Clínico , Neoplasias da Próstata/sangue , Neoplasias da Próstata/tratamento farmacológico , Testosterona/sangue , Idoso , Idoso de 80 Anos ou mais , Hormônio Liberador de Gonadotropina/agonistas , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Neoplasias da Próstata/diagnóstico
5.
Liver Transpl ; 22(1): 111-9, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26390093

RESUMO

We developed a novel technique of subnormothermic ex vivo liver perfusion (SNEVLP) for the storage of liver grafts before transplantation. To test the safety of SNEVLP for the nonextended criteria grafts (standard grafts), we compared it to a control group with minimal cold static storage (CS) time. Heart-beating pig liver retrieval was performed. Grafts were either stored in cold unmodified University of Wisconsin solution (CS-1), in cold University of Wisconsin solution with ex vivo perfusion additives (CS-2), or preserved with a sequence of 3 hours CS and 3 hours SNEVLP (33°C), followed by orthotopic liver transplantation. Liver function tests and histology were investigated. Aspartate aminotransferase (AST) levels during SNEVLP remained stable (54.3 ± 12.6 U/L at 1 hour to 47.0 ± 31.9 U/L at 3 hours). Posttransplantation, SNEVLP versus CS-1 livers had decreased AST levels (peak at day 1, 1081.9 ± 788.5 versus 1546.7 ± 509.3 U/L; P = 0.14; at day 2, 316.7 ± 188.1 versus 948.2 ± 740.9 U/L; P = 0.04) and alkaline phosphatase levels (peak at day 1, 150.4 ± 19.3 versus 203.7 ± 33.6 U/L; P = 0.003). Bilirubin levels were constantly within the physiological range in the SNEVLP group, whereas the CS-1 group presented a large standard deviation, including pathologically increased values. Hyaluronic acid as a marker of endothelial cell (EC) function was markedly improved by SNEVLP during the early posttransplant phase (5 hours posttransplant, 1172.75 ± 598.5 versus 5540.5 ± 2755.4 ng/mL). Peak international normalized ratio was similar between SNEVLP and CS-1 groups after transplantation. Immunohistochemistry for cleaved caspase 3 demonstrated more apoptotic sinusoidal cells in the CS-1 group when compared to SNEVLP grafts 2 hours after reperfusion (19.4 ± 19.5 versus 133.2 ± 48.8 cells/high-power field; P = 0.002). Adding normothermic CS-2 had no impact on liver injury or function after transplantation when compared to CS-1. In conclusion, SNEVLP is safe to use for standard donor grafts and is associated with improved EC and bile duct injury even in grafts with minimal CS time.


Assuntos
Transplante de Fígado , Preservação de Órgãos/métodos , Perfusão , Animais , Ductos Biliares/fisiologia , Células Endoteliais/fisiologia , Testes de Função Hepática , Masculino , Suínos , Transplantes/fisiologia
6.
Am J Physiol Renal Physiol ; 308(2): F77-83, 2015 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-25377916

RESUMO

Plasma uric acid (PUA) is associated with metabolic, cardiovascular, and renal abnormalities in patients with type 2 diabetes but is less well understood in type 1 diabetes (T1D). Our aim was to compare PUA levels and fractional uric acid excretion (FEUA) in patients with T1D vs. healthy controls (HC) during euglycemia and hyperglycemia. PUA, FEUA, blood pressure (BP), glomerular filtration rate (GFR-inulin), and effective renal plasma flow (ERPF-paraaminohippurate) were evaluated in patients with T1D (n = 66) during clamped euglycemia (glucose 4-6 mmol/l) and hyperglycemia (9-11 mmol/l), and in HC (n = 41) during euglycemia. To separate the effects of hyperglycemia vs. increased glycosuria, parameters were evaluated during clamped euglycemia in a subset of T1D patients before and after sodium glucose cotransporter 2 (SGLT2) inhibition for 8 wk. PUA was lower in T1D vs. HC (228 ± 62 vs. 305 ± 75 µmol/l, P < 0.0001). In T1D, hyperglycemia further decreased PUA (228 ± 62 to 199 ± 65 µmol/l, P < 0.0001), which was accompanied by an increase in FEUA (7.3 ± 3.8 to 11.6 ± 6.7, P < 0.0001). In T1D, PUA levels correlated positively with SBP (P = 0.029) and negatively with ERPF (P = 0.031) and GFR (P = 0.028). After induction of glycosuria with SGLT2 inhibition while maintaining clamped euglycemia, PUA decreased (P < 0.0001) and FEUA increased (P < 0.0001). PUA is lower in T1D vs. HC and positively correlates with SBP and negatively with GFR and ERPF in T1D. Glycosuria rather than hyperglycemia increases uricosuria in T1D. Future studies examining the effect of uric acid-lowering therapies should account for the impact of ambient glycemia, which causes an important uricosuric effect.


Assuntos
Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/urina , Glicosúria/sangue , Ácido Úrico/sangue , Ácido Úrico/urina , Adulto , Compostos Benzidrílicos , Estudos de Casos e Controles , Feminino , Glucosídeos , Humanos , Hiperglicemia/sangue , Hiperglicemia/urina , Masculino , Inibidores do Transportador 2 de Sódio-Glicose , Adulto Jovem
7.
Clin Chem Lab Med ; 53(1): 125-32, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25153395

RESUMO

BACKGROUND: The utility of HbA1c for the diagnosis of type 2 diabetes requires an accurate, precise and robust test measurement system. Currently, immunoassay and HPLC are the most popular methods for HbA1c quantification, noting however the limitations associated with some platforms, such as imprecision or interference from common hemoglobin variants. Abbott Diagnostics has introduced a fully automated direct enzymatic method for the quantification of HbA1c from whole blood on the ARCHITECT chemistry system. METHODS: Here we completed a method evaluation of the ARCHITECT HbA1c enzymatic assay for imprecision, accuracy, method comparison, interference from hemoglobin variants and specimen stability. This was completed at three independent clinical laboratories in North America and Europe. RESULTS: The total imprecision ranged from 0.5% to 2.2% CV with low and high level control materials. Around the diagnostic cut-off of 48 mmol/mol, the total imprecision was 0.6% CV. Mean bias using reference samples from IFCC and CAP ranged from -1.1 to 1.0 mmol/mol. The enzymatic assay also showed excellent agreement with HPLC methods, with slopes of 1.01 and correlation coefficients ranging from 0.984 to 0.996 compared to Menarini Adams HA-8160, Bio-Rad Variant II and Variant II Turbo instruments. Finally, no significant effect was observed for erythrocyte sedimentation or interference from common hemoglobin variants in patient samples containing heterozygous HbS, HbC, HbD, HbE, and up to 10% HbF. CONCLUSIONS: The ARCHITECT enzymatic assay for HbA1c is a robust and fully automated method that meets the performance requirements to support the diagnosis of type 2 diabetes.


Assuntos
Aminoácido Oxirredutases/metabolismo , Análise Química do Sangue/métodos , Hemoglobinas Glicadas/análise , Criopreservação , Diabetes Mellitus Tipo 2/sangue , Eritrócitos/citologia , Hemoglobinas Glicadas/metabolismo , Humanos , Modelos Lineares
8.
Liver Transpl ; 20(11): 1296-305, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25179693

RESUMO

An ischemic-type biliary stricture (ITBS) is a common feature after liver transplantation using donation after cardiac death (DCD) grafts. We compared sequential subnormothermic ex vivo liver perfusion (SNEVLP; 33°C) with cold storage (CS) for the prevention of ITBS in DCD liver grafts in pig liver transplantation (n = 5 for each group). Liver grafts were stored for 10 hours at 4°C (CS) or preserved with combined 7-hour CS and 3-hour SNEVLP. Parameters of hepatocyte [aspartate aminotransferase (AST), international normalized ratio (INR), factor V, and caspase 3 immunohistochemistry], endothelial cell (EC; CD31 immunohistochemistry and hyaluronic acid), and biliary injury and function [alkaline phosphatase (ALP), total bilirubin, and bile lactate dehydrogenase (LDH)] were determined. Long-term survival (7 days) after transplantation was similar between the SNEVLP and CS groups (60% versus 40%, P = 0.13). No difference was observed between SNEVLP- and CS-treated animals with respect to the peak of serum INR, factor V, or AST levels within 24 hours. CD31 staining 8 hours after transplantation demonstrated intact EC lining in SNEVLP-treated livers (7.3 × 10(-4) ± 2.6 × 10(-4) cells/µm(2)) but not in CS-treated livers (3.7 × 10(-4) ± 1.3 × 10(-4) cells/µm(2) , P = 0.03). Posttransplant SNEVLP animals had decreased serum ALP and serum bilirubin levels in comparison with CS animals. In addition, LDH in bile fluid was lower in SNEVLP pigs versus CS pigs (14 ± 10 versus 60 ± 18 µmol/L, P = 0.02). Bile duct histology revealed severe bile duct necrosis in 3 of 5 animals in the CS group but none in the SNEVLP group (P = 0.03). Sequential SNEVLP preservation of DCD grafts reduces bile duct and EC injury after liver transplantation.


Assuntos
Transplante de Fígado , Fígado/patologia , Preservação de Órgãos/métodos , Traumatismo por Reperfusão/prevenção & controle , Animais , Ductos Biliares/patologia , Células Endoteliais , Eritrócitos , Hepatócitos , Testes de Função Hepática , Masculino , Perfusão , Suínos
9.
Clin Biochem ; 125: 110731, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38360198

RESUMO

BACKGROUND: An analytical benchmark for high-sensitivity cardiac troponin (hs-cTn) assays is to achieve a coefficient of variation (CV) of ≤ 10.0 % at the 99th percentile upper reference limit (URL) used for the diagnosis of myocardial infarction. Few prospective multicenter studies have evaluated assay imprecision and none have determined precision at the female URL which is lower than the male URL for all cardiac troponin assays. METHODS: Human serum and plasma matrix samples were constructed to yield hs-cTn concentrations near the female URLs for the Abbott, Beckman, Roche, and Siemens hs-cTn assays. These materials were sent (on dry ice) to 35 Canadian hospital laboratories (n = 64 instruments evaluated) participating in a larger clinical trial, with instructions for storage, handling, and monthly testing over one year. The mean concentration, standard deviation, and CV for each instrument type and an overall pooled CV for each manufacturer were calculated. RESULTS: The CVs for all individual instruments and overall were ≤ 10.0 % for two manufacturers (Abbott CVpooled = 6.3 % and Beckman CVpooled = 7.0 %). One of four Siemens Atellica instruments yielded a CV > 10.0 % (CVpooled = 7.7 %), whereas 15 of 41 Roche instruments yielded CVs > 10.0 % at the female URL of 9 ng/L used worldwide (6 cobas e411, 1 cobas e601, 4 cobas e602, and 4 cobas e801) (CVpooled = 11.7 %). Four Roche instruments also yielded CVs > 10.0 % near the female URL of 14 ng/L used in the United States (CVpooled = 8.5 %). CONCLUSIONS: The number of instruments achieving a CV ≤ 10.0 % at the female 99th-percentile URL varies by manufacturer and by instrument. Monitoring assay precision at the female URL is necessary for some assays to ensure optimal use of this threshold in clinical practice.


Assuntos
Infarto do Miocárdio , Humanos , Masculino , Feminino , Estudos Prospectivos , Canadá , Infarto do Miocárdio/diagnóstico , Bioensaio , Troponina , Troponina T , Biomarcadores , Valores de Referência
11.
J Appl Lab Med ; 8(3): 457-468, 2023 05 04.
Artigo em Inglês | MEDLINE | ID: mdl-36869760

RESUMO

BACKGROUND: Preeclampsia is a multisystem disorder defined by new onset of hypertension with proteinuria after 20 weeks gestation. In part due to dysregulation of pro-angiogenic factors (e.g., placental growth factor [PlGF]) and anti-angiogenic factors (e.g., soluble fms-like tyrosine kinase 1 [sFlt-1]), preeclampsia results in decreased placental perfusion. An increased sFlt-1:PlGF ratio is associated with increased risk of preeclampsia. In this study, we evaluated sFlt-1:PlGF cutoffs and evaluated the clinical performance of sFlt-1:PlGF for predicting preeclampsia. METHODS: sFlt-1:PlGF results from 130 pregnant females with clinical suspicion of preeclampsia were used to evaluate the diagnostic accuracy of different sFlt-1:PlGF cutoffs and to compare the clinical performance of sFlt-1:PlGF to traditional preeclampsia markers (proteinuria and hypertension). Serum sFlt-1 and PlGF were measured using Elecsys immunoassays (Roche Diagnostics) and preeclampsia diagnosis was verified by expert chart review. RESULTS: A sFlt-1:PlGF cutoff of >38 yielded the greatest diagnostic accuracy of 90.8% (95% CI, 85.8%-95.7%). Using a cutoff of >38, sFlt-1:PlGF exhibited a greater diagnostic accuracy than traditionally used parameters such as new or worsening proteinuria or hypertension (71.9% and 68.6%, respectively). sFlt-1:PlGF >38 exhibited a negative predictive value (NPV) of 96.4% for rule-out of preeclampsia within 7 days, and a positive predictive value (PPV) of 84.8% for predicting preeclampsia within 28 days. CONCLUSIONS: Our study shows the superior clinical performance of sFlt-1:PlGF over hypertension and proteinuria alone to predict preeclampsia at a high-risk obstetrical unit.


Assuntos
Hipertensão , Pré-Eclâmpsia , Feminino , Humanos , Gravidez , Biomarcadores , Placenta , Fator de Crescimento Placentário , Pré-Eclâmpsia/diagnóstico , Receptor 1 de Fatores de Crescimento do Endotélio Vascular
12.
Adv Clin Chem ; 117: 103-161, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37973318

RESUMO

Preeclampsia is a multisystem hypertensive disorder and one of the leading causes of maternal and fetal morbidity and mortality. The clinical hallmarks such as hypertension and proteinuria, and additional laboratory tests currently available including liver enzyme testing, are neither specific nor sufficiently sensitive. Therefore, biomarkers for timely and accurate identification of patients at risk of developing preeclampsia are extremely valuable to improve patient outcomes and safety. In this chapter, we will first discuss the clinical characteristics of preeclampsia and current evidence of the role of angiogenic factors, such as placental growth factor (PlGF) and soluble FMS like tyrosine kinase 1 (sFlt-1) in the pathogenesis of preeclampsia. Second, we will review the clinical practice guidelines for preeclampsia diagnostic criteria and their recommendations on laboratory testing. Third, we will review the currently available PlGF and sFlt-1 assays in terms of their methodologies, analytical performance, and clinical diagnostic values. Finally, we will discuss the future research needs from both an analytical and clinical perspective.


Assuntos
Hipertensão , Pré-Eclâmpsia , Gravidez , Humanos , Feminino , Pré-Eclâmpsia/diagnóstico , Fator de Crescimento Placentário , Biomarcadores , Fator A de Crescimento do Endotélio Vascular
13.
Clin Biochem ; 116: 1-6, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36849050

RESUMO

BACKGROUND: Semi-quantitative and quantitative immunoassays are the most commonly used methodology to evaluate immunity post immunization. OBJECTIVES: To compare four quantitative SARS-CoV-2 serological assays in COVID-19 patients and immunized healthy individuals, cancer patients, and patients with immunosuppressive therapy. STUDY DESIGN: 210 serological samples from COVID-19 infection and vaccination cohorts were used to create a serological sample repository. Serological methods from four manufacturers, namely Euroimmun, Roche, Abbott, and DiaSorin, were evaluated for quantitative, semi-quantitative, and qualitative antibody measurements. All four methods measure IgG antibodies against the SARS-CoV-2 spike receptor-binding domain and report the results in Binding Antibody Unit/mL (BAU/mL). A Total Error Allowable (TEa) of ±25% was chosen as the criteria to determine whether two methods are clinically equivalent quantitatively. Semi-quantitative results (titers) were derived using numeric antibody concentration divided by the cut-off value for each method. RESULTS: All paired quantitative comparisons demonstrated unacceptable performance. With ±25% as TEa, the best agreement was 74 (35.2% out of 210 samples) between Euroimmun and DiaSorin, whereas the lowest agreement was 11 (5.2% out of 210 samples) between Euroimmun and Roche. Antibody titers amongst all four methods were significantly different (p < 0.001). The highest titer difference from the same sample is between Roche and DiaSorin with a 1392-fold difference. On qualitative comparison, none of the paired comparison showed acceptable comparison (p < 0.001). CONCLUSIONS: Poor correlation exists between four evaluated assays, quantitatively, semi-quantitatively, and qualitatively. Further harmonization of assays is required to achieve comparable measurements.


Assuntos
COVID-19 , Neoplasias , Humanos , COVID-19/diagnóstico , SARS-CoV-2 , Anticorpos Antivirais , Teste para COVID-19 , Imunoglobulina G , Sensibilidade e Especificidade
14.
EJIFCC ; 34(2): 153-166, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37455838

RESUMO

Lithium is the first-line treatment for maintenance therapy in bipolar disorder. It is an effective mood stabilizer agent, and may have potential benefits in neuroprotection and reducing the risk of suicide. Toxicity has been a concern in recent decades, particularly in older adults (≥60 years). In 2019, the Older Adults Task Force within the International Society for Bipolar Disorder (ISBD) published recommendations for age-stratified lithium therapeutic ranges for therapy of Older Age Bipolar Disorder (OABD), namely 0.4 - 0.8 mmol/L for ages 60 to 79 and 0.4 - 0.7 mmol/L for ages 80 and above. Clinical laboratory practice surveys in Canada indicated that adoption and implementation of the proposed ranges has been limited to date. In this article, we describe the approach and steps taken to evaluate and implement recommended lithium therapeutic ranges in Ontario and other provinces in Canada for laboratory quality improvement. Sources of variation in lithium reporting practices are discussed and shared here to highlight potential barriers to implementation. The overall goal of this article is to bring attention across the global laboratory community that lower lithium therapeutic target ranges in older patients are crucial for patient safety in OABD.

15.
Clin Biochem ; 121-122: 110681, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37913837

RESUMO

BACKGROUND: Hemodialysis patients exhibit variable immunogenicity following administration of the SARS-CoV-2 mRNA vaccine. The aim of the current study was to evaluate the use of two commercial assays in the assessment of SARS-CoV-2 antibody response in hemodialysis patients and to compare their utility to commonly used SARS-CoV-2 serological assays developed in Canada. METHODS: We evaluated serologic antibody response in 85 hemodialysis patients up to 6 months after receiving both doses of the Pfizer-BioNTech BNT162b2 COVID-19 mRNA vaccine. In addition, antibody response was assessed in 46 chronic kidney disease patients and 40 COVID-19 naïve health care workers (HCW) up to 3 months and 9 months, respectively. Anti-spike (S) and anti-nucleocapsid (N) levels were measured using Elecsys anti-SARS-CoV-2 immunoassays on the Roche analyzer and compared to ELISA-based detection of anti-S, anti-receptor binding domain (RBD), and anti-N. RESULTS: The Elecsys anti-N immunoassay showed 93 % concordance with the anti-N ELISA. The Elecsys anti-S immunoassay showed 97 % concordance with the anti-S ELISA and 89 % concordance with the anti-RBD ELISA. HCWs exhibited significantly higher anti-S levels relative to hemodialysis patients. Anti-S levels decreased significantly over a 6-month period (p < 0.001) in patients receiving maintenance hemodialysis. In addition, anti-S levels decreased significantly over a 9-month (p < 0.001) and 3-month period (p < 0.001) in HCWs and CKD patients, respectively. CONCLUSIONS: There is high concordance between commercial SARS-CoV-2 serological assays and SARS-CoV-2 serological assays developed in Canada. Hemodialysis patients exhibited varying immunogenicity following two doses of the COVID-19 mRNA vaccine with anti-S levels decreasing over time.


Assuntos
COVID-19 , Insuficiência Renal Crônica , Humanos , Vacinas contra COVID-19 , SARS-CoV-2 , Formação de Anticorpos , Vacina BNT162 , COVID-19/diagnóstico , Anticorpos Antivirais , Diálise Renal , Insuficiência Renal Crônica/terapia
16.
J Appl Lab Med ; 8(5): 856-870, 2023 09 07.
Artigo em Inglês | MEDLINE | ID: mdl-37473432

RESUMO

BACKGROUND: Vitamin D supplementation is common practice for neonates and infants due to limited stores of vitamin D at birth. Although not commonly encountered, vitamin D toxicity can occur due to over-supplementation. However, toxic concentrations are often not included in method validation experiments, and assays often are not validated in the neonatal population. METHODS: We compared serial 25 hydroxy vitamin D [25(OH)D] measurements in pre-term neonates receiving 25(OH)D supplementation and identified 12 patients wherein concentrations of 25(OH)D were above 50 ng/mL (125 nM) that required additional investigations as the 25(OH)D results did not match the clinical picture. Available samples were compared across 4 immunoassay platforms (LIAISON XL, Roche Cobas e602, Abbott Alinity i, and Siemens Centaur XP) and LC-MS/MS. RESULTS: Concentrations of 25(OH)D observed on one individual immunoassay platform (LIAISON XL) fluctuated substantially between subsequent blood draws in select neonates with elevated concentrations. Serum samples from these patients showed variable agreement between LC-MS/MS and other immunoassay platforms. These fluctuations were not explained by the presence of 3-epimer-25(OH)D or 24,25(OH)2D. CONCLUSIONS: Although we were unable to identify a cause for the variable elevated results, our findings suggest that neonatal 25(OH)D measurements alone should not be used for assessment of nutritional monitoring, and that clinical correlation and other laboratory parameters including ionized calcium should be considered.


Assuntos
Espectrometria de Massas em Tandem , Vitamina D , Recém-Nascido , Humanos , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Imunoensaio/métodos , Laboratórios
17.
Can J Diabetes ; 47(1): 43-50.e3, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36180335

RESUMO

OBJECTIVES: Pregnancy may be complicated by gestational diabetes mellitus (GDM) and/or microvascular complications like albuminuria, retinopathy and pre-eclampsia. In this study we aimed to identify whether mechanistic pathways associated with microvascular complications are active in pregnant women with GDM or microvascular disease. METHODS: Urinary albumin excretion and biomarkers of inflammation, lipoprotein metabolism and tubular injury were quantified in 355 pregnant women with and without GDM. Participants underwent fundus photography graded for retinopathy. Adjusted associations between individual biomarkers and each outcome variable of interest, including GDM status, albuminuria and retinopathy, were performed using logistic regression. RESULTS: After adjusting for age, systolic blood pressure, body mass index and ethnicity, significant associations between GDM status and apolipoprotein A1, interleukin (IL)-6, IL-8, soluble tumour necrosis factor receptor-I and -II (sTNFR-I and -II), vascular endothelial growth factor and von Willebrand factor were observed. Increased high-sensitivity C-reactive protein (hsCRP) and sTNFR-II were associated with higher levels of albuminuria. hsCRP and previous GDM were associated with retinopathy. CONCLUSION: Mechanistic pathways associated with microvascular complications appear to be active in pregnant women with GDM or microvascular disease.


Assuntos
Diabetes Gestacional , Doenças Retinianas , Gravidez , Humanos , Feminino , Fatores de Risco , Proteína C-Reativa , Albuminúria , Metabolismo dos Lipídeos , Fator A de Crescimento do Endotélio Vascular , Biomarcadores , Inflamação/complicações , Doenças Retinianas/complicações
18.
BMJ Open Qual ; 12(3)2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37495257

RESUMO

BACKGROUND: Reducing laboratory test overuse is important for high quality, patient-centred care. Identifying priorities to reduce low value testing remains a challenge. OBJECTIVE: To develop a simple, data-driven approach to identify potential sources of laboratory overuse by combining the total cost, proportion of abnormal results and physician-level variation in use of laboratory tests. DESIGN, SETTING AND PARTICIPANTS: A multicentre, retrospective study at three academic hospitals in Toronto, Canada. All general internal medicine (GIM) hospitalisations between 1 April 2010 and 31 October 2017. RESULTS: There were 106 813 GIM hospitalisations during the study period, with median hospital length-of-stay of 4.6 days (IQR: 2.33-9.19). There were 21 tests which had a cumulative cost >US$15 400 at all three sites. The costliest test was plasma electrolytes (US$4 907 775), the test with the lowest proportion of abnormal results was red cell folate (0.2%) and the test with the greatest physician-level variation in use was antiphospholipid antibodies (coefficient of variation 3.08). The five tests with the highest cumulative rank based on greatest cost, lowest proportion of abnormal results and highest physician-level variation were: (1) lactate, (2) antiphospholipid antibodies, (3) magnesium, (4) troponin and (5) partial thromboplastin time. In addition, this method identified unique tests that may be a potential source of laboratory overuse at each hospital. CONCLUSIONS: A simple multidimensional, data-driven approach combining cost, proportion of abnormal results and physician-level variation can inform interventions to reduce laboratory test overuse. Reducing low value laboratory testing is important to promote high value, patient-centred care.


Assuntos
Pacientes Internados , Médicos , Humanos , Estudos Retrospectivos , Hospitalização , Medicina Interna
20.
J Appl Lab Med ; 7(2): 555-567, 2022 03 02.
Artigo em Inglês | MEDLINE | ID: mdl-35233636

RESUMO

BACKGROUND: The ratio of the antiangiogenic factor, soluble fms-like tyrosine kinase 1 (sFlt-1), to the proangiogenic factor, placental growth factor (PlGF), is associated with increased risk of preeclampsia. Here, we describe an analytical evaluation of the Elecsys sFlt-1 and PlGF assays at the first North American site in which they were clinically implemented. METHODS: The analytical evaluation included short- and long-term imprecision, method comparison, accuracy, linearity, sample stability, limit of quantification verification, and measurement uncertainty. Quality indicators were also evaluated, including turnaround time and repeat test frequency. RESULTS: Short-term (13-day) and long-term (12-month) imprecision for sFlt-1 and PlGF were <4% CV. Method comparison (n = 40) between Roche cobas e602 and e411 exhibited r > 0.99 and bias <10%. sFlt-1/PlGF ratio rule-out cutoffs (≤33 and ≤38) and rule-in cutoffs (>38, >85, and >110) exhibited negative percent agreement and positive percent agreement of 100%, respectively (n = 40). During the first 12 months, 257 orders were placed, repeat test frequency was 17.5%, mean time between repeat orders was 23 days, and 72.0% of results were reported within 2 h from sample receipt when quality control was run continuously. CONCLUSIONS: We describe analytical performance parameters and quality indicators of the Elecsys sFlt-1 and PlGF assays, which was the first North American clinical laboratory site to implement these assays in support of the institution's high-risk obstetrical unit.


Assuntos
Indicadores de Qualidade em Assistência à Saúde , Receptor 1 de Fatores de Crescimento do Endotélio Vascular , Biomarcadores , Feminino , Humanos , Imunoensaio/métodos , Fator de Crescimento Placentário , Gravidez