1.
Cytokine ; 111: 481-489, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-29908923

RESUMO

BACKGROUND: Quantification of biofluid cytokines is a rapidly growing area of translational research. However, comparability across the expanding number of available assay platforms for detection of the same proteins remains to be determined. We aimed to directly compare a panel of commonly measured cytokines in plasma of typically aging adults across two high sensitivity quantification platforms, Meso Scale Discovery high performance electrochemiluminiscence (HPE) and single-molecule immunosorbent assays (Simoa) by Quanterix. METHODS: 57 community-dwelling older adults completed a blood draw, neuropsychological assessment, and brain MRI as part of a healthy brain aging study. Plasma samples from the same draw dates were analyzed for IL-10, IP-10, IL-6, TNFα, and IL-1ß on HPE and Simoa, separately. Reliable detectability (coefficient of variance (CV) < 20% and outliers 3 interquartiles above the median removed), intra-assay precision, absolute concentrations, reproducibility across platforms, and concurrent associations with external variables of interest (e.g., demographics, peripheral markers of vascular health, and brain health) were examined. RESULTS: The proportion of cytokines reliably measured on HPE (87.7-93.0%) and Simoa (75.4-93.0%) did not differ (ps > 0.32), with the exception of IL-1ß which was only reliably measured using Simoa (68.4%). On average, CVs were acceptable at <8% across both platforms. Absolute measured concentrations were higher using Simoa for IL-10, IL-6, and TNFα (ps < 0.05). HPE and Simoa shared only small-to-moderate proportions of variance with one another on the same cytokine proteins (range: r = 0.26 for IL-10 to r = 0.64 for IL-6), though platform agreement did not dependent on cytokine concentrations. Cytokine ratios within each platform demonstrated similar relative patterns of up- and down-regulation across HPE and Simoa, though still significantly differed (ps < 0.001). Supporting concurrent validity, all 95% confidence intervals of the correlations between cytokines and external variables overlapped between the two platforms. Moreover, most associations were in expected directions and consistently so across platforms (e.g., IL-6 and TNFα), though with several notable exceptions for IP-10 and IL-10. CONCLUSIONS: HPE and Simoa showed comparable detectability and intra-assay precision measuring a panel of commonly examined cytokine proteins, with the exception of IL-1ß which was not reliably detected on HPE. However, Simoa demonstrated overall higher concentrations and the two platforms did not show agreement when directly compared against one another. Relative cytokine ratios and associations demonstrated similar patterns across platforms. Absolute cytokine concentrations may not be directly comparable across platforms, may be analyte dependent, and interpretation may be best limited to discussion of relative associations.


Assuntos
Biomarcadores/sangue , Biomarcadores/metabolismo , Citocinas/sangue , Citocinas/metabolismo , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Imunoensaio/métodos , Interleucina-10/sangue , Interleucina-10/metabolismo , Interleucina-1beta/sangue , Interleucina-1beta/metabolismo , Interleucina-6/sangue , Interleucina-6/metabolismo , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Fator de Necrose Tumoral alfa/sangue , Fator de Necrose Tumoral alfa/metabolismo
2.
Anal Biochem ; 509: 73-78, 2016 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-27387056

RESUMO

A new technology from Quanterix called SiMoA (single molecule array) which employs a fully automated system capable of ultrasensitive sandwich based ELISA detection was explored. Our studies focused upon the inhibition of the autophagy initiating kinase ULK1 by measuring the both total Atg13 and the phosphorylation of Atg13(pSer(318)) from control and following compound treatment in either overexpressing or wild type tissue culture samples. The results show linear protein concentration dependence over two orders of magnitude and provide an assay window of 8- to 100-fold signal to background for inhibition of phosphorylation for both wild type and overexpressed samples, respectively. Moreover, overexpressed samples displayed 17-fold pSer(318)-Atg13 above wild type levels of with no apparent differences in compound potency. Lastly, the inhibition of ULK1 from mouse derived wild type xenografts also demonstrated loss of pSer(318)-Atg13 upon ULK1 inhibitor treatment that compared favorably to Western blot. These results show that the SiMoA technology can detect quantitatively low levels of endogenous biomarkers with the ability to detect the loss of pSer(318)-Atg13 upon ULK1 inhibition.


Assuntos
Proteínas Adaptadoras de Transdução de Sinal/metabolismo , Proteína Homóloga à Proteína-1 Relacionada à Autofagia/metabolismo , Proteínas Relacionadas à Autofagia/metabolismo , Peptídeos e Proteínas de Sinalização Intracelular/metabolismo , Análise Serial de Proteínas/métodos , Animais , Linhagem Celular Tumoral , Ensaio de Imunoadsorção Enzimática/métodos , Xenoenxertos , Humanos , Camundongos , Transplante de Neoplasias , Fosforilação
3.
J Alzheimers Dis ; 92(1): 241-260, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36744338

RESUMO

BACKGROUND: Phosphorylated cytoplasmic tau inclusions correlate with and precede cognitive deficits in Alzheimer's disease (AD). However, pathological tau accumulation and relationships to synaptic changes remain unclear. OBJECTIVE: To address this, we examined postmortem brain from 50 individuals with the full spectrum of AD (clinically and neuropathologically). Total tau, pTau231, and AMPA GluR1 were compared across two brain regions (entorhinal and middle frontal cortices), as well as clinically stratified groups (control, amnestic mild cognitive impairment, AD dementia), NIA-AA Alzheimer's Disease Neuropathologic Change designations (Not, Low, Intermediate, High), and Braak tangle stages (1-6). Significant co-existing pathology was excluded to isolate changes attributed to pathologic AD. METHODS: Synaptosomal fractionation and staining were performed to measure changes in total Tau, pTau231, and AMPA GluR1. Total Tau and pTau231 were quantified in synaptosomal fractions using Quanterix Simoa HD-X. RESULTS: Increasing pTau231 in frontal postsynaptic fractions correlated positively with increasing clinical and neuropathological AD severity. Frontal cortex is representative of early AD, as it does not become involved by tau tangles until late in AD. Entorhinal total tau was significantly higher in the amnestic mild cognitive impairment group when compared to AD, but only after accounting for AD associated synaptic changes. Alterations in AMPA GluR1 observed in the entorhinal cortex, but not middle frontal cortex, suggest that pTau231 mislocalization and aggregation in postsynaptic structures may impair glutamatergic signaling by promoting AMPA receptor dephosphorylation and internalization. CONCLUSION: Results highlight the potential effectiveness of early pharmacological interventions targeting pTau231 accumulation at the postsynaptic density.


Assuntos
Doença de Alzheimer , Disfunção Cognitiva , Humanos , Doença de Alzheimer/patologia , Proteínas tau/metabolismo , Densidade Pós-Sináptica/metabolismo , Ácido alfa-Amino-3-hidroxi-5-metil-4-isoxazol Propiônico , Encéfalo/patologia , Disfunção Cognitiva/patologia
4.
Am Heart J Plus ; 13: 100110, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38560066

RESUMO

Background: Associations between elevated circulating cardiac troponin I (cTnI) levels and adverse cardiac outcomes were established prior to the ability to measure extremely low levels of cTnI. Immunoassays that achieve precise ultra-highly sensitive quantification of cTnI (u-hs-cTnI) will allow accurate measurement in healthy subjects. We aimed to evaluate the distribution of u-hs-cTnI values measured by (Simoa HD-1 Analyzer, Quanterix Corporation, Lexington, MA) in healthy subjects and characterize relations to sex and age. Methods: Two independent, healthy cohorts (total of 200 women, 200 men) aged 18-86 years were analyzed in duplicate using the u-hs-cTnI Immunoassay. The u-hs-cTnI 99th percentiles were calculated as the upper limits considering a robust estimation against outliers with 90% confidence intervals. The Quanterix immunoassay analytical performance was established and compared to an existing clinical assay (ARCHITECT STAT High Sensitivity Troponin I, Abbott Laboratories, Wiesbaden, Germany). Results: The lower limit of detection of the u-hs-cTnI assay was calculated to be 0.005 ng/L; we accurately quantified u-hs-cTnI in 95% of healthy individuals. The Quanterix immunoassay within overlapping concentrations correlated with the Abbott assay (R2 = 0.932). The calculated combined 99th percentile was 7.94 ng/L (90% Confidence Interval [CI], 5.47-10.52). Women had lower mean u-hs-cTnI concentrations than men under the age of 40 years. The sex-specific 99th percentile for female vs. male individuals was 4.89 ng/L (90%CI, 3.71-6.25) and 10.49 ng/L (90%CI, 5.19-15.06), respectively. Conclusion: The Quanterix immunoassay provides precise quantification in 95% of healthy individuals. Women under the age of 40 years have significantly lower levels of u-hs-cTnI than men.

5.
Curr Med Sci ; 41(3): 618-625, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34169424

RESUMO

Recombinant batroxobin (S3101) is a thrombin-like serine protease that binds to fibrinogen or is taken up by the reticuloendothelial system. A literature survey showed no adequate method that could determine sufficient concentrations to evaluate pharmacokinetic parameters for phase I clinical studies. Therefore, a sensitive method is urgently needed to support the clinical pharmacokinetic evaluation of S3101. In this study, a sensitive bioanalytical method was developed and validated, using a Quanterix single molecular array (Simoa) assay. Moreover, to thoroughly assess the platform, enzyme-linked immunosorbent assay and electrochemiluminescence assay were also developed, and their performance was compared with that of this novel technology platform. The assay was validated in compliance with the current guidelines. Measurements with the Simoa assay were precise and accurate, presenting a valid assay range from 6.55 to 4000 pg/mL. The intra- and inter-run accuracy and precision were within -19.3% to 15.3% and 5.5% to 17.0%, respectively. S3101 was stable in human serum for 280 days at -20°C and -70°C, for 2 h prior to pre-treatment and 24 h post pre-treatment at room temperature (22°C-28°C), respectively, and after five and two freeze-thaw cycles at -70°C and -20°C, respectively. The Simoa assay also demonstrated sufficient dilution linearity, assay sensitivity, and parallelism for quantifying S3101 in human serum. The Simoa assay is a sensitive and adequate method for evaluating the pharmacokinetic parameters of S3101 in human serum.


Assuntos
Batroxobina/sangue , Ensaio de Imunoadsorção Enzimática , Proteínas Recombinantes/sangue , Batroxobina/isolamento & purificação , Batroxobina/farmacocinética , Feminino , Fibrinogênio/metabolismo , Humanos , Masculino , Ligação Proteica/genética , Proteínas Recombinantes/isolamento & purificação , Proteínas Recombinantes/farmacocinética
6.
Bioanalysis ; 12(19): 1377-1388, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32975431

RESUMO

Aim: Tryptase is a tetrameric trypsin-like serine protease contained within the secretory granules of mast cells and is an important mediator of allergic inflammatory responses in respiratory diseases. Detection of active tryptase in the airway may provide important information about asthma and other respiratory diseases. Materials & Methods: An activity based probe has been incorported within an immunoassay to allow for measurement of active tryptase in human tissues. Results: A specific Simoa immunoassay to measure active tryptase in nasosorption samples was developed and qualified using an activity-based probe label and a specific antitryptase capture antibody. Conclusion: The assay was capable of measuring active tryptase in human samples, which will enable evaluation of the role of tryptase proteolytic activity in human disease.


Assuntos
Imunoensaio/métodos , Testes Imunológicos/métodos , Mastócitos/patologia , Triptases/metabolismo , Humanos
7.
Bioanalysis ; 11(11): 1045-1054, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31251105

RESUMO

Aim: IL-13 is a biomarker of type 2 inflammation that plays a critical role in asthma. IL-13 is present in serum at subpicogram levels. Methods: Simoa HD-1 technology was evaluated for the detection and quantitation of IL-13 by using a commercially available IL-13 kit and compared with a Simoa HomeBrew (HB) IL-13 assay as well as Immunological Multi-Parameter Chip Technology (IMPACT), an internal Roche platform. Performance of the assays was evaluated based on preset criteria for sensitivity, standard curve and controls' accuracy and precision, reproducibility and parallelism of endogenous analyte in serum samples. Results: The Simoa platform offered high assay sensitivity for evaluation of IL-13. Conclusion: This paper discusses the challenges and considerations when evaluating kits and/or developing HomeBrew assays using ultrasensitive platforms.


Assuntos
Asma/sangue , Ensaio de Imunoadsorção Enzimática , Interleucina-13/sangue , Humanos
8.
Bioanalysis ; 11(15): 1405-1418, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31401845

RESUMO

Background: Neurofilament light (NfL) chain is an established cerebrospinal fluid (CSF) biomarker for neuroaxonal injury. The highly sensitive Quanterix Simoa™ platform is evaluated for NfL measurement in both CSF and blood. There is a need to link historical ELISA data that use bovine NfL to that of Simoa using a recombinant human (rhuman) NfL standard. Results/Methodology: The Simoa NF-light® Advantage Kit was validated for CSF and qualified for serum and plasma, using both rhuman and bovine NfL calibrators. Matched CSF, serum and plasma samples from 112 multiple sclerosis patients were analyzed using both calibrators. Conclusion: In multiple sclerosis, there is a good correlation between blood and CSF NfL levels. A conversion factor of approximately 5:1 was established between bovine and rhuman NfL calibrators.


Assuntos
Análise Química do Sangue/métodos , Proteínas de Neurofilamentos/sangue , Proteínas de Neurofilamentos/líquido cefalorraquidiano , Animais , Análise Química do Sangue/normas , Calibragem , Bovinos , Humanos , Limite de Detecção , Proteínas de Neurofilamentos/química , Recidiva , Padrões de Referência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA