Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Pediatr Blood Cancer ; 71(9): e31164, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38953144

RESUMO

BACKGROUND: Organs at risk (OAR) dose reporting for total body irradiation (TBI) patients is limited, and standardly reported only as mean doses to the lungs and kidneys. Consequently, dose received and effects on other OAR remain unexplored. To remedy this gap, this study reports dose data on an extensive list of OAR for patients treated at a single institution using the modulated arc total body irradiation (MATBI) technique. METHOD: An audit was undertaken of all patients treated with MATBI between January 2015 and March 2021 who had completed their course of treatment. OAR were contoured on MATBI patient treatment plans, with 12 Gy in six fraction prescription. OAR dose statistics and dose volume histogram data are reported for the whole body, lungs, kidneys, bones, brain, lens, heart, liver and bowel bag. RESULTS: The OAR dose data for 29 patients are reported. Mean dose results are body 11.77 Gy, lungs 9.86 Gy, kidneys 11.84 Gy, bones 12.03 Gy, brain 12.12 Gy, right lens 12.31 Gy, left lens 12.64 Gy, heart 11.07 Gy, liver 11.81 Gy and bowel bag 12.06 Gy. Dose statistics at 1-Gy intervals of V6-V13 for lungs and V10-V13 for kidneys are also included. CONCLUSION: This is the first time an extensive list of OAR data has been reported for any TBI technique. Due to the paucity of reporting, this information could be used by centres implementing the MATBI technique, in addition to aiding comparison between TBI techniques, with the potential for greater understanding of the relationship between dose volume data and toxicity.


Assuntos
Órgãos em Risco , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada , Irradiação Corporal Total , Humanos , Órgãos em Risco/efeitos da radiação , Irradiação Corporal Total/métodos , Criança , Masculino , Feminino , Radioterapia de Intensidade Modulada/métodos , Radioterapia de Intensidade Modulada/efeitos adversos , Pré-Escolar , Adolescente , Planejamento da Radioterapia Assistida por Computador/métodos , Lactente , Adulto , Seguimentos , Prognóstico , Adulto Jovem
2.
J Appl Clin Med Phys ; 25(5): e14345, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38664894

RESUMO

PURPOSE: To establish the clinical applicability of deep-learning organ-at-risk autocontouring models (DL-AC) for brain radiotherapy. The dosimetric impact of contour editing, prior to model training, on performance was evaluated for both CT and MRI-based models. The correlation between geometric and dosimetric measures was also investigated to establish whether dosimetric assessment is required for clinical validation. METHOD: CT and MRI-based deep learning autosegmentation models were trained using edited and unedited clinical contours. Autosegmentations were dosimetrically compared to gold standard contours for a test cohort. D1%, D5%, D50%, and maximum dose were used as clinically relevant dosimetric measures. The statistical significance of dosimetric differences between the gold standard and autocontours was established using paired Student's t-tests. Clinically significant cases were identified via dosimetric headroom to the OAR tolerance. Pearson's Correlations were used to investigate the relationship between geometric measures and absolute percentage dose changes for each autosegmentation model. RESULTS: Except for the right orbit, when delineated using MRI models, the dosimetric statistical analysis revealed no superior model in terms of the dosimetric accuracy between the CT DL-AC models or between the MRI DL-AC for any investigated brain OARs. The number of patients where the clinical significance threshold was exceeded was higher for the optic chiasm D1% than other OARs, for all autosegmentation models. A weak correlation was consistently observed between the outcomes of dosimetric and geometric evaluations. CONCLUSIONS: Editing contours before training the DL-AC model had no significant impact on dosimetry. The geometric test metrics were inadequate to estimate the impact of contour inaccuracies on dose. Accordingly, dosimetric analysis is needed to evaluate the clinical applicability of DL-AC models in the brain.


Assuntos
Neoplasias Encefálicas , Aprendizado Profundo , Imageamento por Ressonância Magnética , Órgãos em Risco , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Tomografia Computadorizada por Raios X , Humanos , Órgãos em Risco/efeitos da radiação , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/diagnóstico por imagem , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Radiometria/métodos , Processamento de Imagem Assistida por Computador/métodos
3.
Rep Pract Oncol Radiother ; 29(3): 300-308, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39144272

RESUMO

Background: Task Group 43 (TG-43) formalism does not consider the tissue and applicator heterogeneities. This study is to compare the effect of model-based dose calculation algorithms, like Advanced Collapsed Cone Engine (ACE), on dose calculation with the TG-43 dose calculation formalism in patients with cervical carcinoma. Materials and methods: 20 patients of cervical carcinoma treated with a high dose rate of intracavitary brachytherapy were prospectively studied. The target volume and organs at risk (OARs) were contoured in the Oncentra treatment planning system (Elekta, Veenendaal, The Netherlands). All patients were planned with cobalt-60 (Co-60) and iridium-192 (Ir-192) sources with doses of 21 Gy in 3 fractions. These plans were calculated with TG-43 formalism and a model-based dose calculation algorithm ACE. The dosimetric parameters of TG-43 and ACE-based plans were compared in terms of target coverage and OAR doses. Results: For Co-60-based plans, the percentage differences in the D90 and V100 values for high-risk clinical target volume (HR-CTV) were 0.36 ± 0.43% and 0.17 ± 0.31%, respectively. For the bladder, rectum and sigmoid, the percentage differences for D2cc volumes were -0.50 ± 0.51%, -0.16 ± 0.53% and -0.37 ± 1.21%, respectively. For Ir-192-based plans, the percentage difference in the D90 for HR-CTV was 0.54 ± 0.79%, while V100 was 0.24 ± 0.29%. For the bladder, rectum and sigmoid, the doses to 2cc volume were 0.35 ± 1.06%, 0.99 ± 0.74% and 0.74 ± 1.92%, respectively. No significant differences were found in the dosimetric parameters calculated with ACE and TG-43. Conclusion: The ACE algorithm reduced doses to OARs and targets. However, ACE and TG-43 did not show significant differences in the dosimetric parameters of the target and OARs with both sources.

4.
Rep Pract Oncol Radiother ; 29(3): 348-356, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39144264

RESUMO

Background: Definitive concurrent chemoradiotherapy (CRT) is the standard of care in advanced stages of head and neck cancer (HNC). With evident increase in survival rate there is also simultaneous increase in toxicity affecting the quality of life. One of the less researched late toxicity is radiation induced brachial plexopathy (RIBP). In this dosimetric study we intent to contour the brachial plexus (BP) as an organ at risk (OAR) and determine the factors that contribute to dose variations to BP, and clinically evaluate the patients for RIBP during follow-up using a questionnaire. Materials and methods: 30 patients with HNC planned for CRT from September 2020 to June 2022 were accrued. Patients were treated to a dose of 6600 cGy with intensity modulated radiotherapy using the simultaneous integrated boost technique. From the dose-volume histogram (DVH) statistics the BP volume, Dmax and other parameters like V66, V60 were assessed and was correlated with respect to primary tumour and nodal stage. Results: On corelation, more than the T stage, the N stage and the primary location had a significant impact on the Dmax. With a median follow-up of 17.9 months, the incidence of RIBP was 6.67%. The 2-year disease free survival and the 2-year overall survival were 53.7% and 59.4%, respectively. Conclusions: In oropharyngeal/hypopharyngeal primaries and in advanced nodal disease, BP receives higher doses contributing to RIBP. Primary tumor and nodal stage also impacted V60 and V66 of BP. Hence, contouring of BP as an OAR becomes imperative, and respecting the DVH parameters is essential.

5.
Clin Transl Radiat Oncol ; 46: 100752, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38425691

RESUMO

Background: Advances in local and systemic therapies have improved the outcomes of patients with breast cancer (BC), leading to a possible increased risk for postoperative radiation therapy (RT) late adverse events. The most adequate technologies and dose constraints for organs at risk (OAR) in BC RT have yet to be defined. Methods: An online survey was distributed to radiation oncologists (ROs) practicing in Europe and Latin America including the Caribbean (LAC) through personal contacts, RO and BC professional groups' networks. Demographic data and clinical practice information were collected. Results:  The study included 585 responses from ROs practicing in 57 different countries. The most frequently contoured OAR by European and LAC participants were the whole heart (96.6 % and 97.7 %), the ipsilateral (84.3 % and 90.8 %), and contralateral lung (71.3 % and 77.4 %), whole lung (69.8 % and 72.9 %), and the contralateral breast (66.4 % and. 83.2 %). ESTRO guidelines were preferred in Europe (33.3 %) and the RTOG contouring guideline was the most popular in LAC (62.2 %), while some participants used both recommendations (13.2 % and 19.2 %). IMRT (68.6 % and 59.1 %) and VMAT (65.6 % and 60.2 %) were the preferred modalities used in heart sparing strategies, followed by deep inspiration breath-hold (DIBH) (54.8 % and 37.4 %) and partial breast irradiation (PBI) (41.6 % and 24.6 %). Only a small percentage of all ROs reported the dose-volume constraints for OAR used in routine clinical practice. A mean heart dose (Heart-Dmean) between 4 and 5 Gy was the most frequently reported parameter (17.2 % and 39.3 %). Conclusion:  The delineation approaches and sparing techniques for OAR in BC RT vary between ROs worldwide. The low response rate to the dose constraints subset of queries reflects the uncertainty surrounding this topic and supports the need for detailed consensus recommendations in the clinical practice.

6.
Phys Med ; 123: 103427, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38959576

RESUMO

BACKGROUND: Reirradiation of head and neck cancer (HNC) became more accessible in the last decade, owing to modern irradiation techniques which offer a reduction in treatment related toxicities. The aim of this paper was to comparatively evaluate the dosimetric aspects derived from intensity modulated photon vs. proton treatment planning in reirradiated HNC patients. METHODS: Six recurrent HNC patients were enrolled in this retrospective study. For each patient two treatment plans were created: one IMRT/VMAT and one IMPT plan. The prescribed dose for the second irradiation was between 50 and 70 Gy RBE. The study comparatively analyzed the CTV coverage, doses to organs at risk (OARs) and low doses received by the healthy tissue (other than OAR). RESULTS: Similar CTV coverage was achieved for photon vs proton plans, with the latter presenting better homogeneity in four cases. Maximum dose to CTV was generally higher for photon plans, with differences ranging from 0.3 to 1.9%. For parotid glands and body, the mean dose was lower for proton plans. A notable reduction of low dose to healthy tissue (other than OARs) could be achieved with protons, with an average of 60% and 64% for D10% and Dmean, respectively. CONCLUSION: The dosimetric comparison between photon and proton reirradiation of HNC showed a great need for treatment individualization, concluding that protons should be considered for reirradiation on an individual basis.


Assuntos
Neoplasias de Cabeça e Pescoço , Órgãos em Risco , Fótons , Terapia com Prótons , Radiometria , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Reirradiação , Humanos , Neoplasias de Cabeça e Pescoço/radioterapia , Terapia com Prótons/métodos , Fótons/uso terapêutico , Radioterapia de Intensidade Modulada/métodos , Reirradiação/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Órgãos em Risco/efeitos da radiação , Estudos Retrospectivos
7.
Front Oncol ; 14: 1335623, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38800394

RESUMO

Purpose: Differences in the contours created during magnetic resonance imaging-guided online adaptive radiotherapy (MRgOART) affect dose distribution. This study evaluated the interobserver error in delineating the organs at risk (OARs) in patients with pancreatic cancer treated with MRgOART. Moreover, we explored the effectiveness of drugs that could suppress peristalsis in restraining intra-fractional motion by evaluating OAR visualization in multiple patients. Methods: This study enrolled three patients who underwent MRgOART for pancreatic cancer. The study cohort was classified into three conditions based on the MRI sequence and butylscopolamine administration (Buscopan): 1, T2 imaging without butylscopolamine administration; 2, T2 imaging with butylscopolamine administration; and 3, multi-contrast imaging with butylscopolamine administration. Four blinded observers visualized the OARs (stomach, duodenum, small intestine, and large intestine) on MR images acquired during the initial and final MRgOART sessions. The contour was delineated on a slice area of ±2 cm surrounding the planning target volume. The dice similarity coefficient (DSC) was used to evaluate the contour. Moreover, the OARs were visualized on both MR images acquired before and after the contour delineation process during MRgOART to evaluate whether peristalsis could be suppressed. The DSC was calculated for each OAR. Results: Interobserver errors in the OARs (stomach, duodenum, small intestine, large intestine) for the three conditions were 0.636, 0.418, 0.676, and 0.806; 0.725, 0.635, 0.762, and 0.821; and 0.841, 0.677, 0.762, and 0.807, respectively. The DSC was higher in all conditions with butylscopolamine administration compared with those without it, except for the stomach in condition 2, as observed in the last session of MR image. The DSCs for OARs (stomach, duodenum, small intestine, large intestine) extracted before and after contouring were 0.86, 0.78, 0.88, and 0.87; 0.97, 0.94, 0.90, and 0.94; and 0.94, 0.86, 0.89, and 0.91 for conditions 1, 2, and 3, respectively. Conclusion: Butylscopolamine effectively reduced interobserver error and intra-fractional motion during the MRgOART treatment.

8.
Diagnostics (Basel) ; 14(15)2024 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-39125508

RESUMO

This study aimed to determine the relationship between geometric and dosimetric agreement metrics in head and neck (H&N) cancer radiotherapy plans. A total 287 plans were retrospectively analyzed, comparing auto-contoured and clinically used contours using a Dice similarity coefficient (DSC), surface DSC (sDSC), and Hausdorff distance (HD). Organs-at-risk (OARs) with ≥200 cGy dose differences from the clinical contour in terms of Dmax (D0.01cc) and Dmean were further examined against proximity to the planning target volume (PTV). A secondary set of 91 plans from multiple institutions validated these findings. For 4995 contour pairs across 19 OARs, 90% had a DSC, sDSC, and HD of at least 0.75, 0.86, and less than 7.65 mm, respectively. Dosimetrically, the absolute difference between the two contour sets was <200 cGy for 95% of OARs in terms of Dmax and 96% in terms of Dmean. In total, 97% of OARs exhibiting significant dose differences between the clinically edited contour and auto-contour were within 2.5 cm PTV regardless of geometric agreement. There was an approximately linear trend between geometric agreement and identifying at least 200 cGy dose differences, with higher geometric agreement corresponding to a lower fraction of cases being identified. Analysis of the secondary dataset validated these findings. Geometric indices are approximate indicators of contour quality and identify contours exhibiting significant dosimetric discordance. For a small subset of OARs within 2.5 cm of the PTV, geometric agreement metrics can be misleading in terms of contour quality.

9.
Med Phys ; 51(3): 2175-2186, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38230752

RESUMO

BACKGROUND: Accurate and consistent contouring of organs-at-risk (OARs) from medical images is a key step of radiotherapy (RT) cancer treatment planning. Most contouring approaches rely on computed tomography (CT) images, but the integration of complementary magnetic resonance (MR) modality is highly recommended, especially from the perspective of OAR contouring, synthetic CT and MR image generation for MR-only RT, and MR-guided RT. Although MR has been recognized as valuable for contouring OARs in the head and neck (HaN) region, the accuracy and consistency of the resulting contours have not been yet objectively evaluated. PURPOSE: To analyze the interobserver and intermodality variability in contouring OARs in the HaN region, performed by observers with different level of experience from CT and MR images of the same patients. METHODS: In the final cohort of 27 CT and MR images of the same patients, contours of up to 31 OARs were obtained by a radiation oncology resident (junior observer, JO) and a board-certified radiation oncologist (senior observer, SO). The resulting contours were then evaluated in terms of interobserver variability, characterized as the agreement among different observers (JO and SO) when contouring OARs in a selected modality (CT or MR), and intermodality variability, characterized as the agreement among different modalities (CT and MR) when OARs were contoured by a selected observer (JO or SO), both by the Dice coefficient (DC) and 95-percentile Hausdorff distance (HD 95 $_{95}$ ). RESULTS: The mean (±standard deviation) interobserver variability was 69.0 ± 20.2% and 5.1 ± 4.1 mm, while the mean intermodality variability was 61.6 ± 19.0% and 6.1 ± 4.3 mm in terms of DC and HD 95 $_{95}$ , respectively, across all OARs. Statistically significant differences were only found for specific OARs. The performed MR to CT image registration resulted in a mean target registration error of 1.7 ± 0.5 mm, which was considered as valid for the analysis of intermodality variability. CONCLUSIONS: The contouring variability was, in general, similar for both image modalities, and experience did not considerably affect the contouring performance. However, the results indicate that an OAR is difficult to contour regardless of whether it is contoured in the CT or MR image, and that observer experience may be an important factor for OARs that are deemed difficult to contour. Several of the differences in the resulting variability can be also attributed to adherence to guidelines, especially for OARs with poor visibility or without distinctive boundaries in either CT or MR images. Although considerable contouring differences were observed for specific OARs, it can be concluded that almost all OARs can be contoured with a similar degree of variability in either the CT or MR modality, which works in favor of MR images from the perspective of MR-only and MR-guided RT.


Assuntos
Neoplasias de Cabeça e Pescoço , Planejamento da Radioterapia Assistida por Computador , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Pescoço , Tomografia Computadorizada por Raios X , Imageamento por Ressonância Magnética , Cabeça , Órgãos em Risco , Variações Dependentes do Observador , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/radioterapia
10.
J Contemp Brachytherapy ; 16(1): 28-34, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38584889

RESUMO

Purpose: The aim of the study was to dosimetrically compare intra-cavitary brachytherapy technique (ICBT) with free-hand (intra-cavitary + interstitial, IC + IS) technique. Material and methods: Twenty seven locally advanced carcinoma cervix patients were included in the study. Patients with more than medial 1/3rd parametrial residual disease without extending upto lateral pelvic wall were included, following external beam radiotherapy (EBRT), in which cobalt-60 high-dose-rate (60Co HDR) brachytherapy source was used. Dose for both plans were 6.5 Gy × 4 fractions, 2 fractions per day, 6 hours apart, over 2 days. Free-hand brachytherapy technique, consisted of placement of central tandem and 2 ovoids along with needles without using template, was applied. Two plans were generated by activating and deactivating the needles, and compared by normalizing to V100. Results: A total of 79 needles were applied. Using paired-t test, dosimetric comparison of both the plans was done. Free-hand plan had a significant higher mean V90 (volume receiving 90% of the dose) of 94.2% compared with 87.22% in ICBT plan (p ≤ 0.0001). Free-hand and ICBT plans presented a mean V100 values of 89.06% and 81.51% (p ≤ 0.0001), respectively, favoring free-hand plan. The mean D90 (dose to 90% volume), D98, and D100 of free-hand plan were 6.28 Gray (Gy), 4.91 Gy, and 3.62 Gy, respectively, but equivalent parameters in ICBT plan were 5.26 Gy, 3.72 Gy, and 2.61 Gy, with p value ≤ 0.0001. In both the plans, D2cc of the bladder, rectum, and sigmoid were 4.59 Gy, 3.98 Gy, 2.77 Gy, and 4.46 Gy, 3.90 Gy, 2.67 Gy, respectively, with no statistical significance. Conclusions: Free-hand brachytherapy (IC + IS) achieves a statistically significant better dose distribution to high-risk clinical target volume (HR-CTV) comparing with ICBT technique with similar dose to organs at risk.

11.
Cureus ; 16(5): e59583, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38832195

RESUMO

Novel hybrid approaches for chest wall irradiation show promising outcomes regarding target coverage and sparing organs at risk (OARs). In this systematic review, we compared hybrid volumetric modulated arc therapy (H-VMAT) or hybrid intensity-modulated radiotherapy (H-IMRT) techniques with non-hybrid techniques, such as three-dimensional conformal radiation therapy (3DCRT), field-in-field (FIF), intensity-modulated arc therapy (IMRT), and volumetric modulated arc therapy (VMAT), for breast cancer patients with mastectomy. Our focus was the plan quality and dose distribution to the OARs. Using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) checklist, we performed a systematic review and quality appraisal of primary studies evaluating hybrid therapy to the chest wall and the OARs. An extensive online search of PubMed and Scopus databases was conducted using appropriate keywords. The dose to the OARs (lung, heart, and contralateral breast), planning target volume (PTV), homogeneity index (HI), and conformity index (CI) were extracted. The data were then tabulated and compared for the outcomes between modalities among the studies. Nine studies that met the search criteria were selected to evaluate the PTV coverage and dosimetric results of hybrid and non-hybrid techniques. In terms of 95% PTV coverage, among nine reviewed studies, the largest difference between the two techniques was between VMAT (47.6 Gy) and H-VMAT (48.4 Gy); for the conformity index, the largest difference was noted between 3DCRT (0.58) and H-VMAT (0.79). In both cases, differences were statistically significant (P < 0.005). Two studies showed dose homogeneity improvement within the treatment target in H-VMAT (0.15 and 0.07) compared with 3DCRT (0.41 and 0.12), with a P value of <0.001. Two studies did not report on the homogeneity index, and three others observed no statistical difference. Regarding OARs, in the comparison of H-VMAT and VMAT, the largest significant change was in the volume receiving 5 Gy (V5Gy) of the ipsilateral lung and the V10Gy of the contralateral lung. For the ipsilateral lung, V5Gy was 90.7% with VMAT versus 51.45% with H-VMAT. For the contralateral lung, V10Gy was 54.9% with VMAT versus 50.5% with H-VMAT. In six studies, the mean dose of the contralateral breast was lower in hybrid techniques than in single modalities: VMAT (4.2%, 6.0%, 1.9%, 7.1%, 4.57%) versus H-VMAT (1.4%, 3.4%, 1.8%, 3.5%, 2.34%) and IMRT (9.1%) versus H-IMRT (4.69%). Although most studies did not report on monitor units and treatment time, those that included them showed that hybrids had lower monitor units and shorter treatment times. Hybrid techniques in radiotherapy, such as combining two modalities, can indeed facilitate lower doses to OARs for patients with a high risk of toxicities. Prospective clinical studies are needed to determine the outcomes of breast cancer treated with hybrid techniques.

12.
Clin Oncol (R Coll Radiol) ; 36(6): e154-e162, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38553363

RESUMO

BACKGROUND AND PURPOSE: For high-risk neuroblastoma, planning target volume coverage is often compromised to respect adjacent kidney tolerance. This trial investigated whether intensity-modulated arc radiotherapy techniques (IMAT) could facilitate dose escalation better than conventional techniques. MATERIALS AND METHODS: Children with high-risk abdominal neuroblastoma referred for radiotherapy to the primary tumour site and involved regional lymph nodes were randomised to receive either standard dose (21 Gy in 14 fractions) or escalated dose (36 Gy in 24 fractions) radiotherapy. Dual planning with both a conventional anterior-posterior parallel opposed pair radiotherapy technique and an IMAT technique was performed. The quality of target volume and organ-at-risk delineation, and dosimetric plans, were externally reviewed. Dosimetric parameters were used to judge the superior technique for treatment. This feasibility trial was not powered to detect improvement in outcome with dose escalation. RESULTS: Between 2017 and 2020, 50 patients were randomised and dual-planned. The IMAT technique was judged more favourable in 48 patients. In all patients randomised to receive 36 Gy, IMAT would have permitted delivery of the full dose (median D50% 36.0 Gy, inter-quartile range 36.0-36.1 Gy) to the target volume, whereas dose compromise would have been required with conventional planning (median D50% 35.6 Gy, inter-quartile range 28.7-35.9 Gy). CONCLUSION: IMAT facilitates safe dose escalation to 36 Gy in patients receiving radiotherapy for neuroblastoma. The value of dose escalation is now being evaluated in a current prospective phase III randomised trial.


Assuntos
Estudos de Viabilidade , Neuroblastoma , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada , Humanos , Neuroblastoma/radioterapia , Radioterapia de Intensidade Modulada/métodos , Masculino , Feminino , Pré-Escolar , Criança , Lactente , Planejamento da Radioterapia Assistida por Computador/métodos , Órgãos em Risco/efeitos da radiação
13.
Radiother Oncol ; 198: 110410, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38917883

RESUMO

BACKGROUND AND PURPOSE: To promote the development of auto-segmentation methods for head and neck (HaN) radiation treatment (RT) planning that exploit the information of computed tomography (CT) and magnetic resonance (MR) imaging modalities, we organized HaN-Seg: The Head and Neck Organ-at-Risk CT and MR Segmentation Challenge. MATERIALS AND METHODS: The challenge task was to automatically segment 30 organs-at-risk (OARs) of the HaN region in 14 withheld test cases given the availability of 42 publicly available training cases. Each case consisted of one contrast-enhanced CT and one T1-weighted MR image of the HaN region of the same patient, with up to 30 corresponding reference OAR delineation masks. The performance was evaluated in terms of the Dice similarity coefficient (DSC) and 95-percentile Hausdorff distance (HD95), and statistical ranking was applied for each metric by pairwise comparison of the submitted methods using the Wilcoxon signed-rank test. RESULTS: While 23 teams registered for the challenge, only seven submitted their methods for the final phase. The top-performing team achieved a DSC of 76.9 % and a HD95 of 3.5 mm. All participating teams utilized architectures based on U-Net, with the winning team leveraging rigid MR to CT registration combined with network entry-level concatenation of both modalities. CONCLUSION: This challenge simulated a real-world clinical scenario by providing non-registered MR and CT images with varying fields-of-view and voxel sizes. Remarkably, the top-performing teams achieved segmentation performance surpassing the inter-observer agreement on the same dataset. These results set a benchmark for future research on this publicly available dataset and on paired multi-modal image segmentation in general.


Assuntos
Neoplasias de Cabeça e Pescoço , Imageamento por Ressonância Magnética , Órgãos em Risco , Planejamento da Radioterapia Assistida por Computador , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Imageamento por Ressonância Magnética/métodos , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/radioterapia , Órgãos em Risco/efeitos da radiação , Planejamento da Radioterapia Assistida por Computador/métodos
14.
Radiother Oncol ; 194: 110145, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38341093

RESUMO

BACKGROUND AND PURPOSE: Adaptive radiotherapy (ART) relies on re-planning to correct treatment variations, but the optimal timing of re-planning to account for dose changes in head and neck organs at risk (OARs) is still under investigation. We aimed to find out the optimal timing of re-planning in head and neck ART. MATERIALS AND METHODS: A total of 110 head and neck cancer patients were retrospectively enrolled. A semi auto-segmentation method was applied to obtain the weekly mean dose (Dmean) to OARs. The K-nearest-neighbour method was used for missing data imputation of weekly Dmean. A dose deviation map was built using the planning Dmean and weekly Dmean values and then used to simulate different ART scenarios consisting of 1 to 6 re-plannings. The difference between accumulated Dmean and planning Dmean before re-planning (ΔDmean_acc_noART) and after re-planning (ΔDmean_acc_ART) were evaluated and compared. RESULTS: Among all the OARs, supraglottic showed the largest ΔDmean_acc_noART (1.23 ± 3.13 Gy) and most cases of ΔDmean_acc_noART > 3 Gy (26 patients). The 3rd week is suggested in the optimal timing of re-planning for 10 OARs. For all the organs except arytenoid, 2 re-plannings were able to guarantee the ΔDmean_acc_ART below 3 Gy while the average |ΔDmean_acc_ART| was below 1 Gy. ART scenarios of 2_4, 3_4, 3_5 (week of re-planning separated with "_") were able to guarantee ΔDmean_acc_ART of 99 % of patients below 3 Gy simultaneously for 19 OARs. CONCLUSIONS: The optimal timing of re-planning was suggested for different organs at risk in head and neck adaptive radiotherapy. Generic scenarios of timing and frequency for re-planning can be applied to guarantee the increase of accumulated mean dose within 3 Gy simultaneously for multiple organs.


Assuntos
Neoplasias de Cabeça e Pescoço , Órgãos em Risco , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Humanos , Neoplasias de Cabeça e Pescoço/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Estudos Retrospectivos , Órgãos em Risco/efeitos da radiação , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Fatores de Tempo , Adulto , Radioterapia de Intensidade Modulada/métodos , Idoso de 80 Anos ou mais
15.
Artigo em Inglês | MEDLINE | ID: mdl-38192583

RESUMO

Purpose: To investigate estimated delivered dose distributions using weekly cone-beam computed tomography (CBCT) scans for pelvic organs at risk (OARs) in salvage radiotherapy (SRT) after radical prostatectomy. Furthermore, to compare them with the originally planned dose distributions and analyse associations with gastrointestinal (GI) and genitourinary (GU) side effects. Methods: This study is part of a phase II trial involving SRT for recurrent prostate cancer. Treatment was personalised based on PSA response during SRT, classifying patients as PSA responders or non-responders. Estimated radiation dose distributions were obtained using deformable image registration from weekly CBCT scans. GI and GU toxicities were assessed using the RTOG toxicity scale, while patient-reported symptoms were monitored through self-assessment questionnaires. Results: The study included 100 patients, with similar treatment-related side effects observed in both responders and non-responders. Differences in dose-volume metrics between the planned and estimated delivered doses for the examined OARs were mostly modest, although generally statistically significant. We identified statistically significant associations between QUANTEC-recommended dose-volume constraints and acute bowel toxicity, as well as late urinary patient-reported symptoms, for both the estimated delivered and planned dose distributions. Conclusion: We found small but statistically significant differences between estimated delivered and planned doses to OARs. These differences showed trends toward improved associations for estimated delivered dose distributions with side effects. Enhanced registration methods and imaging techniques could potentially further enhance the assessment of truly delivered doses and yield more reliable dose-volume constraints for future therapies.

16.
Radiat Oncol ; 19(1): 4, 2024 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-38191400

RESUMO

BACKGROUND: The aim of the present study is to examine the impact of kV-CBCT-based online adaptive radiation therapy (ART) on dosimetric parameters in comparison to image-guided-radiotherapy (IGRT) in consecutive patients with tumors in the head and neck region from a prospective registry. METHODS: The study comprises all consecutive patients with tumors in the head and neck area who were treated with kV-CBCT-based online ART or IGRT-modus at the linear-accelerator ETHOS™. As a measure of effectiveness, the equivalent-uniform-dose was calculated for the CTV (EUDCTV) and organs-at-risk (EUDOAR) and normalized to the prescribed dose. As an important determinant for the need of ART the interfractional shifts of anatomic landmarks related to the tongue were analyzed and compared to the intrafractional shifts. The latter determine the performance of the adapted dose distribution on the verification CBCT2 postadaptation. RESULTS: Altogether 59 consecutive patients with tumors in the head-and-neck-area were treated from 01.12.2021 to 31.01.2023. Ten of all 59 patients (10/59; 16.9%) received at least one phase within a treatment course with ART. Of 46 fractions in the adaptive mode, irradiation was conducted in 65.2% of fractions with the adaptive-plan, the scheduled-plan in the remaining. The dispersion of the distributions of EUDCTV-values from the 46 dose fractions differed significantly between the scheduled and adaptive plans (Ansari-Bradley-Test, p = 0.0158). Thus, the 2.5th percentile of the EUDCTV-values by the adaptive plans amounted 97.1% (95% CI 96.6-99.5%) and by the scheduled plans 78.1% (95% CI 61.8-88.7%). While the EUDCTV for the accumulated dose distributions stayed above 95% at PTV-margins of ≥ 3 mm for all 8 analyzed treatment phases the scheduled plans did for margins ≥ 5 mm. The intrafractional anatomic shifts of all 8 measured anatomic landmarks were smaller than the interfractional with overall median values of 8.5 mm and 5.5 mm (p < 0.0001 for five and p < 0.05 for all parameters, pairwise comparisons, signed-rank-test). The EUDOAR-values for the larynx and the parotid gland were significantly lower for the adaptive compared with the scheduled plans (Wilcoxon-test, p < 0.001). CONCLUSIONS: The mobile tongue and tongue base showed considerable interfractional variations. While PTV-margins of 5 mm were sufficient for IGRT, ART showed the potential of decreasing PTV-margins and spare dose to the organs-at-risk.


Assuntos
Neoplasias de Cabeça e Pescoço , Radioterapia Guiada por Imagem , Humanos , Planejamento da Radioterapia Assistida por Computador , Neoplasias de Cabeça e Pescoço/radioterapia , Cabeça , Pescoço
17.
Phys Imaging Radiat Oncol ; 29: 100527, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38222671

RESUMO

Background and purpose: Autocontouring for radiotherapy has the potential to significantly save time and reduce interobserver variability. We aimed to assess the performance of a commercial autocontouring model for head and neck (H&N) patients in eight orientations relevant to particle therapy with fixed beam lines, focusing on validation and implementation for routine clinical use. Materials and methods: Autocontouring was performed on sixteen organs at risk (OARs) for 98 adult and pediatric patients with 137 H&N CT scans in eight orientations. A geometric comparison of the autocontours and manual segmentations was performed using the Hausdorff Distance 95th percentile, Dice Similarity Coefficient (DSC) and surface DSC and compared to interobserver variability where available. Additional qualitative scoring and dose-volume-histogram (DVH) parameters analyses were performed for twenty patients in two positions, consisting of scoring on a 0-3 scale based on clinical usability and comparing the mean (Dmean) and near-maximum (D2%) dose, respectively. Results: For the geometric analysis, the model performance in head-first-supine straight and hyperextended orientations was in the same range as the interobserver variability. HD95, DSC and surface DSC was heterogeneous in other orientations. No significant geometric differences were found between pediatric and adult autocontours. The qualitative scoring yielded a median score of ≥ 2 for 13/16 OARs while 7/32 DVH parameters were significantly different. Conclusions: For head-first-supine straight and hyperextended scans, we found that 13/16 OAR autocontours were suited for use in daily clinical practice and subsequently implemented. Further development is needed for other patient orientations before implementation.

18.
Diagnostics (Basel) ; 14(5)2024 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-38472938

RESUMO

Multi-criteria optimization (MCO) function has been available on commercial radiotherapy (RT) treatment planning systems to improve plan quality; however, no study has compared Eclipse and RayStation MCO functions for prostate RT planning. The purpose of this study was to compare prostate RT MCO plan qualities in terms of discrepancies between Pareto optimal and final deliverable plans, and dosimetric impact of final deliverable plans. In total, 25 computed tomography datasets of prostate cancer patients were used for Eclipse (version 16.1) and RayStation (version 12A) MCO-based plannings with doses received by 98% of planning target volume having 76 Gy prescription (PTV76D98%) and 50% of rectum (rectum D50%) selected as trade-off criteria. Pareto optimal and final deliverable plan discrepancies were determined based on PTV76D98% and rectum D50% percentage differences. Their final deliverable plans were compared in terms of doses received by PTV76 and other structures including rectum, and PTV76 homogeneity index (HI) and conformity index (CI), using a t-test. Both systems showed discrepancies between Pareto optimal and final deliverable plans (Eclipse: -0.89% (PTV76D98%) and -2.49% (Rectum D50%); RayStation: 3.56% (PTV76D98%) and -1.96% (Rectum D50%)). Statistically significantly different average values of PTV76D98%,HI and CI, and mean dose received by rectum (Eclipse: 76.07 Gy, 0.06, 1.05 and 39.36 Gy; RayStation: 70.43 Gy, 0.11, 0.87 and 51.65 Gy) are noted, respectively (p < 0.001). Eclipse MCO-based prostate RT plan quality appears better than that of RayStation.

19.
J Natl Cancer Cent ; 2(4): 306-313, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-39036546

RESUMO

Precision radiotherapy is a critical and indispensable cancer treatment means in the modern clinical workflow with the goal of achieving "quality-up and cost-down" in patient care. The challenge of this therapy lies in developing computerized clinical-assistant solutions with precision, automation, and reproducibility built-in to deliver it at scale. In this work, we provide a comprehensive yet ongoing, incomplete survey of and discussions on the recent progress of utilizing advanced deep learning, semantic organ parsing, multimodal imaging fusion, neural architecture search and medical image analytical techniques to address four corner-stone problems or sub-problems required by all precision radiotherapy workflows, namely, organs at risk (OARs) segmentation, gross tumor volume (GTV) segmentation, metastasized lymph node (LN) detection, and clinical tumor volume (CTV) segmentation. Without loss of generality, we mainly focus on using esophageal and head-and-neck cancers as examples, but the methods can be extrapolated to other types of cancers. High-precision, automated and highly reproducible OAR/GTV/LN/CTV auto-delineation techniques have demonstrated their effectiveness in reducing the inter-practitioner variabilities and the time cost to permit rapid treatment planning and adaptive replanning for the benefit of patients. Through the presentation of the achievements and limitations of these techniques in this review, we hope to encourage more collective multidisciplinary precision radiotherapy workflows to transpire.

20.
Radiol. bras ; 42(5): 303-308, set.-out. 2009. graf, tab
Artigo em Português | LILACS | ID: lil-530178

RESUMO

OBJETIVO: Comparar e quantificar os volumes pulmonares irradiados utilizando planejamentos bidimensional (2D) e tridimensional (3D) conformado na radioterapia de tumores de pulmão. MATERIAIS E MÉTODOS: Em 27 pacientes portadores de câncer de pulmão foi feito planejamento 3D e outro correspondente em 2D. As doses prescritas variaram de 45 a 66 Gy. Foram avaliadas as doses no volume alvo planejado (PTV), volume tumoral macroscópico (GTV) e pulmões (volume de pulmão que recebe 20 Gy ou 30 Gy - V20 e V30, respectivamente, e dose média). Os órgãos de risco adjacentes (medula espinhal, esôfago e coração) receberam doses abaixo dos limites de tolerância. RESULTADOS: O GTV variou de 10,5 a 1.290,0 cm³ (média de 189,65 cm³). Nos planejamentos 2D foi utilizado, em média, um total de 59,33 campos, e nos planejamentos 3D, 75,65 campos. Em todas as situações analisadas houve significante (p < 0,05) preservação dos volumes pulmonares com o planejamento 3D, com diminuição de cerca de 15 por cento dos volumes irradiados. O pulmão sem tumor foi mais beneficiado. CONCLUSÃO: A radioterapia 3D permitiu maior preservação dos pulmões, tanto para tumores iniciais quanto avançados. A radioterapia 3D deve ser utilizada nos pacientes com tumores de pulmão, mesmo que volumosos.


OBJECTIVE: To compare and quantify irradiated lung volumes using two-dimensional (2D) and three-dimensional (3D) conformal planning for radiotherapy in the treatment of lung cancer. MATERIALS AND METHODS: 2D and 3D conformal radiotherapy plannings were performed for 27 patients with lung cancer. Prescribed doses ranged from 45 to 66 Gy. The analysis covered the doses to planning target volume (PTV), gross tumor volume (GTV) and lungs (lung volume receiving 20 Gy or 30 Gy - V20 and V30, respectively, and mean dose). The doses to adjacent organs at risk (spinal cord, esophagus and heart) were maintained below the tolerance limits. RESULTS: GTV ranged from 10.5 to 1,290.0 cm³ (mean, 189.65 cm³). On average, a total of 59.33 fields were utilized in the 2D planning and 75.65 fields in the 3D planning. Lung volumes were significantly preserved (P < 0.05) with the 3D conformal planning in all the evaluated cases, with about 15 percent decrease in the irradiated lung volumes. Lungs without tumor were most benefited from this technique. CONCLUSION: 3D radiotherapy allowed a better sparing of the lungs, both in cases of early and advanced tumors. 3D radiotherapy should be used in the treatment of patients with lung cancer, even in cases of large tumors.


Assuntos
Humanos , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/radioterapia , Radioterapia/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA