Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Sensors (Basel) ; 24(7)2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38610527

RESUMO

Electrothermal piezoresistive resonant cantilever sensors have been fabricated with embedded actuating (heating resistor) and sensing (piezo resistors) parts, with the latter configured in a Wheatstone bridge circuit. Due to the close spacing between these two elements, a direct thermal parasitic effect on the resonant sensor during the actuating-sensing process leads to asymmetric amplitude and reversing phase spectral responses. Such a condition affects the precise determination of the cantilever's resonant frequency, f0. Moreover, in the context of phase-locked loop-based (PLL) resonance tracking, a reversing phase spectral response hinders the resonance locking due to its ambiguity. In this work, a replica of the baseline spectral was applied to remove the thermal parasitic effect on the resonance spectra of the cantilever sensor, and its capability was simulated through mathematical analysis. This replica spectral was subtracted from the parasitized spectral using a particular calculation, resulting in optimized spectral responses. An assessment using cigarette smoke particles performed a desired spectral shifting into symmetrical amplitude shapes and monotonic phase transitions, subsequently allowing for real-time PLL-based frequency tracking.

2.
Sensors (Basel) ; 23(7)2023 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-37050430

RESUMO

It is expected that human iPS cell-derived cardiomyocytes (hiPSC-CMs) can be used to treat serious heart diseases. However, the properties and functions of human adult cardiomyocytes and hiPSC-CMs, including cell maturation, differ. In this study, we focused on the temperature dependence of hiPSC-CMs by integrating the temperature regulation system into our sensor platform, which can directly and quantitatively measure their mechanical motion. We measured the beating frequency of hiPSC-CMs at different environmental temperatures and found that the beating frequency increased as the temperature increased. Although the rate at which the beating frequency increased with temperature varied, the temperature at which the beating stopped was relatively stable at approximately 20 °C. The stopping of beating at this temperature was stable, even in immature hiPSC-CMs, and was considered to be a primitive property of cardiomyocytes.


Assuntos
Células-Tronco Pluripotentes Induzidas , Sistemas Microeletromecânicos , Adulto , Humanos , Células-Tronco Pluripotentes Induzidas/fisiologia , Temperatura , Diferenciação Celular , Miócitos Cardíacos/fisiologia , Células Cultivadas
3.
Sensors (Basel) ; 23(4)2023 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-36850600

RESUMO

We addressed the coating 5 mm-long cantilever microprobes with a viscoelastic material, which was intended to considerably extend the range of the traverse speed during the measurements of the 3D surface topography by damping contact-induced oscillations. The damping material was composed of epoxy glue, isopropyl alcohol, and glycerol, and its deposition onto the cantilever is described, as well as the tests of the completed cantilevers under free-oscillating conditions and in contact during scanning on a rough surface. The amplitude and phase of the cantilever's fundamental out-of-plane oscillation mode was investigated vs. the damping layer thickness, which was set via repeated coating steps. The resonance frequency and quality factor decreased with the increasing thickness of the damping layer for both the free-oscillating and in-contact scanning operation mode, as expected from viscoelastic theory. A very low storage modulus of E'≈100kPa, a loss modulus of E″≈434kPa, and a density of ρ≈1.2gcm-3 were yielded for the damping composite. Almost critical damping was observed with an approximately 130 µm-thick damping layer in the free-oscillating case, which was effective at suppressing the ringing behavior during the high-speed in-contact probing of the rough surface topography.

4.
Sensors (Basel) ; 21(12)2021 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-34198533

RESUMO

An electrothermal piezoresistive cantilever (EPC) sensor is a low-cost MEMS resonance sensor that provides self-actuating and self-sensing capabilities. In the platform, which is of MEMS-cantilever shape, the EPC sensor offers several advantages in terms of physical, chemical, and biological sensing, e.g., high sensitivity, low cost, simple procedure, and quick response. However, a crosstalk effect is generated by the coupling of parasitic elements from the actuation part to the sensing part. This study presents a parasitic feedthrough subtraction (PFS) method to mitigate a crosstalk effect in an electrothermal piezoresistive cantilever (EPC) resonance sensor. The PFS method is employed to identify a resonance phase that is, furthermore, deployed to a phase-locked loop (PLL)-based system to track and lock the resonance frequency of the EPC sensor under cigarette smoke exposure. The performance of the EPC sensor is further evaluated and compared to an AFM-microcantilever sensor and a commercial particle counter (DC1100-PRO). The particle mass-concentration measurement result generated from cigarette-smoke puffs shows a good agreement between these three detectors.


Assuntos
Sistemas Microeletromecânicos , Fumar
5.
Sensors (Basel) ; 20(3)2020 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-31979161

RESUMO

In this study, we investigate the performance of two piezoresistive micro-electro-mechanical system (MEMS)-based silicon cantilever sensors for measuring target analytes (i.e., ultrafine particulate matters). We use two different types of cantilevers with geometric dimensions of 1000 × 170 × 19.5 µm3 and 300 × 100 × 4 µm3, which refer to the 1st and 2nd types of cantilevers, respectively. For the first case, the cantilever is configured to detect the fundamental in-plane bending mode and is actuated using a resistive heater. Similarly, the second type of cantilever sensor is actuated using a meandering resistive heater (bimorph) and is designed for out-of-plane operation. We have successfully employed these two cantilevers to measure and monitor the changes of mass concentration of carbon nanoparticles in air, provided by atomizing suspensions of these nanoparticles into a sealed chamber, ranging from 0 to several tens of µg/m3 and oversize distributions from ~10 nm to ~350 nm. Here, we deploy both types of cantilever sensors and operate them simultaneously with a standard laboratory system (Fast Mobility Particle Sizer, FMPS, TSI 3091) as a reference.

6.
Sensors (Basel) ; 20(13)2020 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-32630829

RESUMO

Tracking of biological and physiological processes on the nanoscale is a central part of the growing field of nanomedicine. Although atomic force microscopy (AFM) is one of the most appropriate techniques in this area, investigations in non-transparent fluids such as human blood are not possible with conventional AFMs due to limitations caused by the optical readout. Here, we show a promising approach based on self-sensing cantilevers (SSC) as a replacement for optical readout in biological AFM imaging. Piezo-resistors, in the form of a Wheatstone bridge, are embedded into the cantilever, whereas two of them are placed at the bending edge. This enables the deflection of the cantilever to be precisely recorded by measuring the changes in resistance. Furthermore, the conventional acoustic or magnetic vibration excitation in intermittent contact mode can be replaced by a thermal excitation using a heating loop. We show further developments of existing approaches enabling stable measurements in turbid liquids. Different readout and excitation methods are compared under various environmental conditions, ranging from dry state to human blood. To demonstrate the applicability of our laser-free bio-AFM for nanomedical research, we have selected the hemostatic process of blood coagulation as well as ultra-flat red blood cells in different turbid fluids. Furthermore, the effects on noise and scanning speed of different media are compared. The technical realization is shown (1) on a conventional optical beam deflection (OBD)-based AFM, where we replaced the optical part by a new SSC nose cone, and (2) on an all-electric AFM, which we adapted for measurements in turbid liquids.


Assuntos
Acústica , Microscopia de Força Atômica , Nanomedicina , Humanos
7.
Micromachines (Basel) ; 13(5)2022 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-35630112

RESUMO

Wearable sensor devices with minimal discomfort to the wearer have been widely developed to realize continuous measurements of vital signs (body temperature, blood pressure, respiration rate, and pulse wave) in many applications across various fields, such as healthcare and sports. Among them, microelectromechanical systems (MEMS)-based differential pressure sensors have garnered attention as a tool for measuring pulse waves with weak skin tightening. Using a MEMS-based piezoresistive cantilever with an air chamber as the pressure change sensor enables highly sensitive pulse-wave measurements to be achieved. Furthermore, the initial static pressure when attaching the sensor to the skin is physically excluded because of air leakage around the cantilever, which serves as a high-pass filter. However, if the frequency characteristics of this mechanical high-pass filter are not appropriately designed, then the essential information of the pulse-wave measurement may not be reflected. In this study, the frequency characteristics of a sensor structure is derived theoretically based on the air leakage rate and chamber size. Subsequently, a pulse wave sensor with a MEMS piezoresistive cantilever element, two air chambers, and a skin-contacted membrane is designed and fabricated. The developed sensor is 30 mm in diameter and 8 mm in thickness and realizes high-pass filter characteristics of 0.7 Hz. Finally, pulse wave measurement at the neck of a participant is demonstrated using the developed sensor. It is confirmed that the measured pulse wave contains signals in the designed frequency band.

8.
Micromachines (Basel) ; 12(5)2021 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-33946579

RESUMO

Angular acceleration sensors are attracting attention as sensors for monitoring rotational vibration. Many angular acceleration sensors have been developed; however, multiaxis measurement is still in a challenging stage. In this study, we propose a biaxial angular acceleration sensor with two uniaxial sensor units arranged orthogonally. The sensor units consist of two rotational-symmetric spiral channels and microelectromechanical system (MEMS) piezoresistive cantilevers. The cantilever is placed to interrupt the flow at the junctions of parallelly aligned spirals in each channel. When two cantilevers are used as the resistance of the bridge circuit in the two-gauge method, the rotational-symmetric spiral channels enhance the sensitivity in the target axis, while the nontarget axis sensitivities are canceled. The fabricated device responds with approximately constant sensitivity from 1 to 15 Hz, with a value of 3.86 × 10-5/(rad/s2), which is equal to the theoretical value. The nontarget axis sensitivity is approximately 1/400 of the target axis sensitivity. In addition, we demonstrate that each unit responds according to the tilt angle when the device is tilted along the two corresponding rotational axis planes. Thus, it is concluded that the developed device realizes biaxial angular acceleration measurement with low crosstalk.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA