1.
Sensors (Basel) ; 23(13)2023 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-37447995

RESUMO

We investigate the MEMS resonant cantilevers for high-performance thermogravimetric analysis (TGA) of chemical decomposition, featuring high accuracy and minimized thermal lag. Each resonant cantilever is integrated with a microheater for sample heating near the free end, which is thermally isolated from the resonance excitation and readout elements at the fixed end. Combining finite element modeling and experiments, we demonstrate that the sample loading region can stabilize within ~11.2 milliseconds in response to a step heating of 500 °C, suggesting a very fast thermal response of the MEMS resonant cantilevers of more than 104 °C/s. Benefiting from such a fast thermal response, we perform high-performance TG measurements on basic copper carbonate (Cu2(OH)2CO3) and calcium oxalate monohydrate (CaC2O4·H2O). The measured weight losses better agree with the theoretical values with 5-10 times smaller thermal lags at the same heating rate, compared with those measured by using conventional TGA. The MEMS resonant cantilevers hold promise for highly accurate and efficient TG characterization of materials in various fields.

2.
Micromachines (Basel) ; 14(5)2023 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-37241554

RESUMO

The traditional thermal gravimetric analyzer (TGA) has a noticeable thermal lag effect, which restricts the heating rate, while the micro-electro-mechanical system thermal gravimetric analyzer (MEMS TGA) utilizes a resonant cantilever beam structure with high mass sensitivity, on-chip heating, and a small heating area, resulting in no thermal lag effect and a fast heating rate. To achieve high-speed temperature control for MEMS TGA, this study proposes a dual fuzzy proportional-integral-derivative (PID) control method. The fuzzy control adjusts the PID parameters in real-time to minimize overshoot while effectively addressing system nonlinearities. Simulation and actual testing results indicate that this temperature control method has a faster response speed and less overshoot compared to traditional PID control, significantly improving the heating performance of MEMS TGA.

3.
Micromachines (Basel) ; 13(3)2022 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-35334737

RESUMO

Combined use of thermal analysis techniques can realize complementarity of different characterization methods. Comprehensive thermal analysis with both thermogravimetric analysis and differential thermal analysis (TG/DTA) can measure not only mass change of a sample but also its temperature change during programmed heating-induced reaction or phase transition processes, thereby obtaining multiaspect thermal information of the material such as dehydration, structural decomposition, phase change and thermal stability. This study proposes and develops a MEMS chip-based TG/DTA microsystem that integrates both programmed heating and detecting elements into a TG chip and a DTA chip to enable the microinstrument performing TG/DTA joint characterization under microscope observation. The TG chip contains a self-heating resonant microcantilever to measure heating-induced mass change of a sample and the DTA chip is with a microheater and a temperature-detecting thermopile integrated on a suspended thermal-insulating diaphragm. Only nanogram and microgram-level samples are needed for the TG and DTA chips, thereby achieving safe measurement to energetic materials such as strong oxidants. The chip-based microinstrument surpasses the state-of-the-art commercial TG/DTA instruments that have, in the long term, suffered from large sample-amount (milligram level) requirements and have been unable to measure energetic materials. Compared with commercial instruments, the chip-based microinstrument is advantageous given its more accurate analysis, much higher heating rate, much smaller instrument volume and much lower power consumption, etc. The microinstrument has been fabricated by using wafer-level MEMS techniques. Testing results show that the mass-detection sensitivity of the TG-chip is as high as 0.45 Hz/pg in air and the temperature sensitivity of the DTA chip achieves 2.9 mV/K under the high heating rate of 25 °C/s. The strong oxidant of KMnO4 is analyzed with the TG/DTA joint characterization under microscopic observation. At the same time as microscope observation of the thermal decomposition phenomena, two-step thermal decomposition process of KMnO4 is identified and the thermal decomposition temperatures are obtained. The TG/DTA microinstrument is promising to be applied for study of various materials.

4.
Talanta ; 182: 148-155, 2018 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-29501134

RESUMO

Micromechanical resonant sensor offers many advantages for chemical detection, but it fails to maintain high quality factor (Q-factor) when working directly in liquid because of the viscous damping. To solve the problem, a gas/liquid separated sensing method is introduced to detect volatile organic compounds (VOCs) in solution with a resonant cantilever gas sensor. With the help of a waterproof and breathable expanded polytetrafluoroethylene (ePTFE) film, the resonant sensor can be physically isolated from the analyte solution. Thus, the sensor can resonate in gas phase environment with a high Q-factor, meanwhile the interference from the solvent emission can be significantly suppressed. Loaded with the sensing-group functionalized mesoporous-silica nanoparticles (MSNs), the resonant cantilever can detect the target VOC molecules that permeate from the flowing solution sample at the other side of the film. Two typical kind of resonant microcantilever VOC sensors are tested to verify the proposed method, which are loaded with carboxyl (-COOH) and amino (-NH2) sensing groups functionalized MSNs, respectively. The sensors exhibit highly sensitive (mg/L level resolution) and reproducible detection ability to aniline and acetic-acid solution, respectively. This gas/liquid separated sensing technique is promising in various on-site chemical detection applications.