Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.645
Filtrar
Más filtros

Intervalo de año de publicación
1.
Proc Natl Acad Sci U S A ; 121(3): e2309842121, 2024 Jan 16.
Artículo en Inglés | MEDLINE | ID: mdl-38194447

RESUMEN

Cardiac contractions and hemodynamic forces are essential for organ development and homeostasis. Control over cardiac contractions can be achieved pharmacologically or optogenetically. However, these approaches lack specificity or require direct access to the heart. Here, we compare two genetic approaches to control cardiac contractions by modulating the levels of the essential sarcomeric protein Tnnt2a in zebrafish. We first recombine a newly generated tnnt2a floxed allele using multiple lines expressing Cre under the control of cardiomyocyte-specific promoters, and show that it does not recapitulate the tnnt2a/silent heart mutant phenotype in embryos. We show that this lack of early cardiac contraction defects is due, at least in part, to the long half-life of tnnt2a mRNA, which masks the gene deletion effects until the early larval stages. We then generate an endogenous Tnnt2a-eGFP fusion line that we use together with the zGRAD system to efficiently degrade Tnnt2a in all cardiomyocytes. Using single-cell transcriptomics, we find that Tnnt2a depletion leads to cardiac phenotypes similar to those observed in tnnt2a mutants, with a loss of blood and pericardial flow-dependent cell types. Furthermore, we achieve conditional degradation of Tnnt2a-eGFP by splitting the zGRAD protein into two fragments that, when combined with the cpFRB2-FKBP system, can be reassembled upon rapamycin treatment. Thus, this Tnnt2a degradation line enables non-invasive control of cardiac contractions with high spatial and temporal specificity and will help further understand how they shape organ development and homeostasis.


Asunto(s)
Perciformes , Pez Cebra , Animales , Pez Cebra/genética , Degrones , Miocitos Cardíacos , Alelos
2.
Proc Natl Acad Sci U S A ; 120(23): e2221244120, 2023 06 06.
Artículo en Inglés | MEDLINE | ID: mdl-37252999

RESUMEN

Missense variant Ile79Asn in human cardiac troponin T (cTnT-I79N) has been associated with hypertrophic cardiomyopathy and sudden cardiac arrest in juveniles. cTnT-I79N is located in the cTnT N-terminal (TnT1) loop region and is known for its pathological and prognostic relevance. A recent structural study revealed that I79 is part of a hydrophobic interface between the TnT1 loop and actin, which stabilizes the relaxed (OFF) state of the cardiac thin filament. Given the importance of understanding the role of TnT1 loop region in Ca2+ regulation of the cardiac thin filament along with the underlying mechanisms of cTnT-I79N-linked pathogenesis, we investigated the effects of cTnT-I79N on cardiac myofilament function. Transgenic I79N (Tg-I79N) muscle bundles displayed increased myofilament Ca2+ sensitivity, smaller myofilament lattice spacing, and slower crossbridge kinetics. These findings can be attributed to destabilization of the cardiac thin filament's relaxed state resulting in an increased number of crossbridges during Ca2+ activation. Additionally, in the low Ca2+-relaxed state (pCa8), we showed that more myosin heads are in the disordered-relaxed state (DRX) that are more likely to interact with actin in cTnT-I79N muscle bundles. Dysregulation of the myosin super-relaxed state (SRX) and the SRX/DRX equilibrium in cTnT-I79N muscle bundles likely result in increased mobility of myosin heads at pCa8, enhanced actomyosin interactions as evidenced by increased active force at low Ca2+, and increased sinusoidal stiffness. These findings point to a mechanism whereby cTnT-I79N weakens the interaction of the TnT1 loop with the actin filament, which in turn destabilizes the relaxed state of the cardiac thin filament.


Asunto(s)
Miofibrillas , Troponina T , Humanos , Miofibrillas/genética , Miofibrillas/patología , Troponina T/genética , Troponina T/química , Actinas/genética , Mutación , Citoesqueleto de Actina/genética , Miosinas , Calcio
3.
Physiol Genomics ; 56(6): 436-444, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38586874

RESUMEN

This study aimed to investigate the relationship between pre- and postexercise cardiac biomarker release according to athletic status (trained vs. untrained) and to establish whether the I/D polymorphism in the angiotensin-converting enzyme (ACE) gene had an influence on cardiac biomarkers release with specific regard on the influence of the training state. We determined cardiac troponin I (cTnI) and N-terminal pro-brain natriuretic peptide (NT-proBNP) in 29 trained and 27 untrained male soccer players before and after moderate-intensity continuous exercise (MICE) and high-intensity interval exercise (HIIE) running tests. Trained soccer players had higher pre (trained: 0.014 ± 0.007 ng/mL; untrained: 0.010 ± 0.005 ng/mL) and post HIIE (trained: 0.031 ± 0.008 ng/mL; untrained: 0.0179 ± 0.007) and MICE (trained: 0.030 ± 0.007 ng/mL; untrained: 0.018 ± 0.007) cTnI values than untrained subjects, but the change with exercise (ΔcTnI) was similar between groups. There was no significant difference in baseline and postexercise NT-proBNP between groups. NT-proBNP levels were elevated after both HIIE and MICE. Considering three ACE genotypes, the mean pre exercise cTnI values of the trained group (DD: 0.015 ± 0.008 ng/mL, ID: 0.015 ± 0.007 ng/mL, and II: 0.014 ± 0.008 ng/mL) and their untrained counterparts (DD: 0.010 ± 0.004 ng/mL, ID: 0.011 ± 0.004 ng/mL, and II: 0.010 ± 0.006 ng/mL) did not show any significant difference. To sum up, noticeable difference in baseline cTnI was observed, which was related to athletic status but not ACE genotypes. Neither athletic status nor ACE genotypes seemed to affect the changes in cardiac biomarkers in response to HIIE and MICE, indicating that the ACE gene does not play a significant role in the release of exercise-induced cardiac biomarkers indicative of cardiac damage in Iranian soccer players.NEW & NOTEWORTHY Our study investigated the impact of athletic status and angiotensin-converting enzyme (ACE) gene I/D polymorphism on cardiac biomarkers in soccer players. Trained players showed higher baseline cardiac troponin I (cTnI) levels, whereas postexercise ΔcTnI remained consistent across groups. N-terminal pro-brain natriuretic peptide increased after exercise in both groups, staying within normal limits. ACE genotypes did not significantly affect pre-exercise cTnI. Overall, athletic status influences baseline cTnI, but neither it nor ACE genotypes significantly impact exercise-induced cardiac biomarker responses in this population.


Asunto(s)
Biomarcadores , Ejercicio Físico , Péptido Natriurético Encefálico , Fragmentos de Péptidos , Peptidil-Dipeptidasa A , Polimorfismo Genético , Troponina I , Masculino , Humanos , Peptidil-Dipeptidasa A/genética , Biomarcadores/sangre , Péptido Natriurético Encefálico/sangre , Péptido Natriurético Encefálico/genética , Troponina I/sangre , Troponina I/genética , Fragmentos de Péptidos/sangre , Ejercicio Físico/fisiología , Adulto Joven , Adulto , Entrenamiento de Intervalos de Alta Intensidad/métodos , Fútbol/fisiología , Mutación INDEL/genética , Corazón/fisiología
4.
J Biol Chem ; 299(1): 102767, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36470422

RESUMEN

PKA-mediated phosphorylation of sarcomeric proteins enhances heart muscle performance in response to ß-adrenergic stimulation and is associated with accelerated relaxation and increased cardiac output for a given preload. At the cellular level, the latter translates to a greater dependence of Ca2+ sensitivity and maximum force on sarcomere length (SL), that is, enhanced length-dependent activation. However, the mechanisms by which PKA phosphorylation of the most notable sarcomeric PKA targets, troponin I (cTnI) and myosin-binding protein C (cMyBP-C), lead to these effects remain elusive. Here, we specifically altered the phosphorylation level of cTnI in heart muscle cells and characterized the structural and functional effects at different levels of background phosphorylation of cMyBP-C and with two different SLs. We found Ser22/23 bisphosphorylation of cTnI was indispensable for the enhancement of length-dependent activation by PKA, as was cMyBP-C phosphorylation. This high level of coordination between cTnI and cMyBP-C may suggest coupling between their regulatory mechanisms. Further evidence for this was provided by our finding that cardiac troponin (cTn) can directly interact with cMyBP-C in vitro, in a phosphorylation- and Ca2+-dependent manner. In addition, bisphosphorylation at Ser22/Ser23 increased Ca2+ sensitivity at long SL in the presence of endogenously phosphorylated cMyBP-C. When cMyBP-C was dephosphorylated, bisphosphorylation of cTnI increased Ca2+ sensitivity and decreased cooperativity at both SLs, which may translate to deleterious effects in physiological settings. Our results could have clinical relevance for disease pathways, where PKA phosphorylation of cTnI may be functionally uncoupled from cMyBP-C phosphorylation due to mutations or haploinsufficiency.


Asunto(s)
Proteínas Portadoras , Proteínas Quinasas Dependientes de AMP Cíclico , Miofibrillas , Troponina I , Calcio/metabolismo , Proteínas Quinasas Dependientes de AMP Cíclico/metabolismo , Miocardio/metabolismo , Miofibrillas/metabolismo , Fosforilación , Troponina I/metabolismo , Proteínas Portadoras/metabolismo
5.
Crit Rev Clin Lab Sci ; 61(1): 1-22, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37466395

RESUMEN

Acute myocardial infarction (AMI) is a leading cause of mortality globally, highlighting the need for timely and accurate diagnostic strategies. Cardiac troponin has been the biomarker of choice for detecting myocardial injury. A dynamic change in concentrations supports the diagnosis of AMI in the setting of evidence of acute myocardial ischemia. The new generation of high-sensitivity cardiac troponin (hs-cTn) assays has significantly improved analytical sensitivity but at the expense of decreased clinical specificity. As a result, sophisticated algorithms are required to differentiate AMI from non-AMI patients. Establishing optimal hs-cTn cutoffs for these algorithms to rule out and rule in AMI has been the subject of intensive investigations. These efforts have evolved from examining the utility of the hs-cTn 99th percentile upper reference limit, comparing the percentage versus absolute delta thresholds, and evaluating the performance of an early European Society of Cardiology-recommended 3 h algorithm, to the development of accelerated 1 h and 2 h algorithms that combine the admission hs-cTn concentrations and absolute delta cutoffs to rule out and rule in AMI. Specific cutoffs for individual confounding factors such as sex, age, and renal insufficiency have also been investigated. At the same time, concerns such as whether the small delta thresholds exceed the analytical and biological variations of hs-cTn assays and whether the algorithms developed in European study populations fit all other patient cohorts have been raised. In addition, the accelerated algorithms leave a substantial number of patients in a non-diagnostic observation zone. How to properly diagnose patients falling in this zone and those presenting with elevated baseline hs-cTn concentrations due to the presence of confounding factors or comorbidities remain open questions. Here we discuss the developments described above, focusing on criteria and underlying considerations for establishing optimal cutoffs. In-depth analyses are provided on the influence of biological variation, analytical imprecision, local AMI rate, and the timing of presentation on the performance metrics of the accelerated hs-cTn algorithms. Developing diagnostic strategies for patients who remain in the observation zone and those presenting with confounding factors are also reviewed.


Asunto(s)
Infarto del Miocardio , Humanos , Infarto del Miocardio/diagnóstico , Biomarcadores , Algoritmos , Troponina , Medición de Riesgo
6.
Small ; : e2402676, 2024 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-38847072

RESUMEN

Fluorescent lateral flow immunoassays (FLFIA) is a well-established rapid detection technique for quantitative analysis. However, achieving accurate analysis of biomarkers at the pg mL-1 level using FLFIA still poses challenges. Herein, an ultrasensitive FLFIA platform is reported utilizing a kiwi-type magneto-fluorescent silica nanohybrid (designated as MFS) that serves as both a target-enrichment substrate and an optical signal enhancement label. The spatially-layered architecture comprises a Fe3O4 core, an endocarp-fibers like dendritic mesoporous silica, seed-like quantum dots, and a kiwi-flesh like silica matrix. The MFS demonstrates heightened fluorescence brightness, swift magnetic response, excellent size uniformity, and dispersibility in water. Through liquid-phase capturing and fluorescence-enhanced signal amplification, as well as magnetic-enrichment sample amplification and magnetic-separation noise reduction, the MFS-based FLFIA is successfully applied to the detection of cardiac troponin I that achieved a limit of detection at 8.4 pg mL-1, tens of times lower than those of previously published fluorescent and colorimetric lateral flow immunoassays. This work offers insights into the strategic design of magneto-fluorescent synergetic signal amplification on LFIA platform and underscores their prospects in high-sensitive rapid and on-site diagnosis of biomarkers.

7.
Cardiovasc Diabetol ; 23(1): 83, 2024 02 24.
Artículo en Inglés | MEDLINE | ID: mdl-38402162

RESUMEN

BACKGROUND: Whether distributions and prognostic values of high-sensitivity cardiac troponin (hs-cTn) T and I are different across normoglycemic, prediabetic, and diabetic populations is unknown. METHODS: 10127 adult participants from the National Health and Nutrition Examination Survey 1999-2004 with determined glycemic status and measurement of at least one of hs-cTn assays were included, from whom healthy participants and presumably healthy diabetic and prediabetic participants were selected to investigate pure impacts of glycemic status on distributions of hs-cTn. The nonparametric method and bootstrapping were used to derive the 99th upper reference limits of hs-cTn and 95% CI. Participants with available follow-up and hs-cTn concentrations of all 4 assays were included in prognostic analyses. Associations of hs-cTn with all-cause and cardiac-specific mortality were modeled by Cox proportional hazard regression under the complex survey design. The incremental value of hs-cTn to an established risk score in predicting cardiac-specific mortality was assessed by the 10-year area under time-dependent receiver operating characteristic curve (AUC) using the Fine-Grey competing risk model. RESULTS: Among 9714 participants included in prognostic analyses, 5946 (61.2%) were normoglycemic, 2172 (22.4%) prediabetic, and 1596 (16.4%) diabetic. Hyperglycemic populations were older than the normoglycemic population but sex and race/ethnicity were similar. During the median follow-up of 16.8 years, hs-cTnT and hs-cTnI were independently associated with all-cause and cardiac-specific mortality across glycemic status. In the diabetic population, adjusted hazard ratios per 1-standard deviation increase of log-transformed hs-cTnT and hs-cTnI (Abbott) concentrations were 1.77 (95% CI 1.48-2.12; P < .001) and 1.83 (95% CI 1.33-2.53; P < .001), respectively, regarding cardiac-specific mortality. In the diabetic but not the normoglycemic population, adding either hs-cTnT (difference in AUC: 0.062; 95% CI 0.038-0.086; P < 0.001) or hs-cTnI (Abbott) (difference in AUC: 0.071; 95% CI 0.046-0.097; P < 0.001) would significantly increase the discriminative ability of the risk score; AUC of the score combined with hs-cTnT would be further improved by incorporating hs-cTnI (0.018; 95%CI 0.006-0.029; P = 0.002). The 99th percentile of hs-cTnT of the presumably healthy diabetic population was higher than the healthy population and had no overlap in 95% CIs, however, for hs-cTnI 99th percentiles of the two populations were very close and 95% CIs extensively overlapped. CONCLUSIONS: Hs-cTnT and hs-cTnI demonstrated consistent prognostic associations across glycemic status but incremental predictive values in hyperglycemic populations only. The susceptibility of hs-cTnT 99th percentiles to diabetes plus the additive value of hs-cTnI to hs-cTnT in diabetic cardiovascular risk stratification suggested hs-cTnI and hs-cTnT may be differentially associated with glycemic status, but further research is needed to illustrate the interaction between hyperglycemia and hs-cTn.


Asunto(s)
Infarto del Miocardio , Estado Prediabético , Adulto , Humanos , Pronóstico , Troponina T , Infarto del Miocardio/diagnóstico , Biomarcadores , Encuestas Nutricionales , Estado Prediabético/diagnóstico , Troponina I
8.
Anal Biochem ; 689: 115505, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38460900

RESUMEN

Cardiovascular diseases (CVD) are a range of diseases, pointing the functional hindrances in the heart and blood vessels of the human system that contributes to 48.6 % of the world's adult death rate. The diagnosis of CVD relies upon the Electro Cardio Gram (ECG) and detection of muscle markers such as troponins. Among the cardiac trio, Cardiac Troponin I (cTnI) weighing 23 KiloDalton (kDa) is a sorted biomarker for CVD. cTnI remains high in the blood after 1-2 weeks of myocardial damage. Testing of cTnI in CVD patients aids in diagnosis and risk stratification of the disease. Different determination systems including optical, electrochemical, and acoustic have been put forward for monitoring the cTnI which are Point of Care (POC) that promotes simple and sensitive detection of cTnI. The modern era has paved way to high-sensitivity Troponin I (hscTnI) devices that can detect up to 0.01 ng/ml in human blood/plasma/serum. Yet, the practice of hscTnI is impracticable due to cost inefficiency. Development of new hscTnI devices with minimal investment and maximal detection range will meet the global requirement. This review gives an over view on different detection systems of cardiac troponin I which stands as a translational detection molecule for CVDs.


Asunto(s)
Enfermedades Cardiovasculares , Troponina I , Adulto , Humanos , Troponina T , Relevancia Clínica , Biomarcadores
9.
Clin Chem Lab Med ; 62(4): 729-739, 2024 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-37937808

RESUMEN

OBJECTIVES: Chronic myocardial injury (CMI) is defined as stable concentrations of cardiac troponin T or I (cTnT or cTnI) above the assay-specific 99th percentile upper reference limit (URL) and signals poor outcome. The clinical implications of diagnosing CMI are unclear. We aimed to assess prevalence and association of CMI with long-term prognosis using three different high-sensitivity cTn (hs-cTn) assays. METHODS: A total of 1,292 hospitalized patients without acute myocardial injury had cTn concentrations quantified by hs-cTn assays by Roche Diagnostics, Abbott Diagnostics and Siemens Healthineers. The median follow-up time was 4.1 years. The prevalence of CMI and hazard ratios for mortality and cardiovascular (CV) events were calculated based on the URL provided by the manufacturers and compared to the prognostic accuracy when lower percentiles of cTn (97.5, 95 or 90), limit of detection or the estimated bioequivalent concentrations between assays were used as cutoff values. RESULTS: There was no major difference in prognostic accuracy between cTnT and cTnI analyzed as continuous variables. The correlation between cTnT and cTnI was high (r=0.724-0.785), but the cTnT assay diagnosed 3.9-4.5 times more patients with having CMI based on the sex-specific URLs (TnT, n=207; TnI Abbott, n=46, TnI Siemens, n=53) and had higher clinical sensitivity and AUC at the URL. CONCLUSIONS: The prevalence of CMI is highly assay-dependent. cTnT and cTnI have similar prognostic accuracy for mortality or CV events when measured as continuous variables. However, a CMI diagnosis according to cTnT has higher prognostic accuracy compared to a CMI diagnosis according to cTnI.


Asunto(s)
Síndrome Coronario Agudo , Masculino , Femenino , Humanos , Pronóstico , Síndrome Coronario Agudo/diagnóstico , Troponina T , Troponina I , Bioensayo , Biomarcadores
10.
Clin Chem Lab Med ; 62(2): 361-370, 2024 Jan 26.
Artículo en Inglés | MEDLINE | ID: mdl-37556843

RESUMEN

OBJECTIVES: End-stage renal disease is associated with a high risk of cardiovascular disease. We compared the concentration and prognostic ability of high sensitivity cardiac troponin T (hs-cTnT) and I (hs-cTnI) and cardiac myosin-binding protein C (cMyC) among stable hemodialysis patients. METHODS: Patients were sampled before and after hemodialysis. We measured hs-cTnI, hs-cTnT and cMyC and used Cox regressions to assess the association between quartiles of concentrations and all-cause mortality and a combination of cardiovascular events and all-cause mortality during follow-up. RESULTS: A total of 307 patients were included, 204 males, mean age 66 years (SD 14). Before dialysis, 299 (99 %) had a hs-cTnT concentration above the 99th percentile, compared to 188 (66 %) for cMyC and 35 (11 %) for hs-cTnI. Hs-cTnT (23 %, p<0.001) and hs-cTnI (15 %, p=0.049) but not cMyC (4 %, p=0.256) decreased during dialysis. Follow-up was a median of 924 days (492-957 days); patients in the 3rd and 4th quartiles of hs-cTnT (3rd:HR 3.0, 95 % CI 1.5-5.8, 4th:5.2, 2.7-9.8) and the 4th quartile of hs-cTnI (HR 3.8, 2.2-6.8) had an increased risk of mortality. Both were associated with an increased risk of the combined endpoint for patients in the 3rd and 4th quartiles. cMyC concentrations were not associated with risk of mortality or cardiovascular event. CONCLUSIONS: Hs-cTnT was above the 99th percentile in almost all patients. This was less frequent for hs-cTnI and cMyC. High cTn levels were associated with a 3-5-fold higher mortality. This association was not present for cMyC. These findings are important for management of hemodialysis patients.


Asunto(s)
Infarto del Miocardio , Masculino , Humanos , Anciano , Estudios de Cohortes , Biomarcadores , Infarto del Miocardio/diagnóstico , Troponina T , Diálisis Renal , Troponina I
11.
Clin Chem Lab Med ; 62(5): 979-987, 2024 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-37999934

RESUMEN

OBJECTIVES: To evaluate the analytical characteristics of a novel high-sensitivity cardiac troponin T (hs-cTnT) test on the automatic light-initiated chemiluminescent assay (LiCA®) system, and validated its diagnostic performance for non-ST-segment elevation myocardial infarction (NSTEMI). METHODS: Studies included an extensive analytical evaluation and established the 99th percentile upper reference limit (URL) from apparently healthy individuals, followed by a diagnostic performance validation for NSTEMI. RESULTS: Sex-specific 99th percentile URLs were 16.0 ng/L (1.7 % CV: coefficient of variation) for men (21-92 years) and 13.4 ng/L (2.0 % CV) for women (23-87 years) in serum, and 30.6 ng/L (0.9 % CV) for men (18-87 years) and 20.2 ng/L (1.4 % CV) for women (18-88 years) in heparin plasma. Detection rates in healthy individuals ranged from 98.9 to 100 %. An excellent agreement was identified between LiCA® and Elecsys® assays with a correlation coefficient of 0.993 and mean bias of -0.7 % (-1.8-0.4 %) across the full measuring range, while the correlation coefficient and overall bias were 0.967 and -1.1 % (-2.5-0.3 %) for the lower levels of cTnT (10-100 ng/L), respectively. At the specific medical decision levels (14.0 and 52.0 ng/L), assay difference was estimated to be <5.0 %. No significant difference was found between these two assays in terms of area under curve (AUC), sensitivity and specificity, negative predictive value (NPV) and positive predictive value (PPV) for the diagnosis of NSTEMI. CONCLUSIONS: LiCA® hs-cTnT is a reliable 3rd-generation (level 4) high-sensitivity assay for detecting cardiac troponin T. The assay is acceptable for practical use in the diagnosis of NSTEMI.


Asunto(s)
Infarto del Miocardio , Infarto del Miocardio sin Elevación del ST , Infarto del Miocardio con Elevación del ST , Masculino , Humanos , Femenino , Troponina T , Infarto del Miocardio/diagnóstico , Heparina , Sensibilidad y Especificidad , Biomarcadores
12.
Clin Chem Lab Med ; 62(2): 353-360, 2024 Jan 26.
Artículo en Inglés | MEDLINE | ID: mdl-37746851

RESUMEN

OBJECTIVES: Cardiac troponin (cTn) is the key biomarker for diagnosis of acute coronary syndrome (ACS). We performed a complete assessment of the high-sensitivity cardiac troponin I (hs-cTnI) (CLIA) assay on the analytical performance and clinical diagnostic performance, which was compared with Abbott ARCHITECT hs-cTnI assay. METHODS: Sex-specific 99th percentile upper reference limits (URLs) were determined from a healthy population of 424 males and 408 females. High-sensitivity performance was assessed by examining the imprecision at sex-specific URLs and the detectable results above LoD in a cohort of healthy population. The diagnostic performance of the hs-cTnI (CLIA) assay was validated in a population of 934 patients with suspected ACS. RESULTS: The 99th percentile URLs were 15.3 ng/L for female, 31.3 ng/L for male and 24.2 ng/L for overall population. The total imprecision near the sex-specific 99th percentile URLs were <5 %. 76.74 % of females, 97.12 % of males and 86.69 % of overall population had cTnI values exceeding the LoD, which met the criteria of high-sensitivity troponin assay. No cross-reactivity or interference was identified. The diagnostic sensitivity, specificity, PPV, NPV, and AUC of hs-cTnI (CLIA) assay were 97.97 , 90.70, 79.02, 99.21 % and 0.9885, respectively, which were comparable to ARCHITECT hs-cTnI assay. CONCLUSIONS: hs-cTnI (CLIA) assay is a high-sensitivity troponin I method with high precision, sensitivity and specificity. The clinical diagnostic performance of hs-cTnI (CLIA) is comparable to the established ARCHITECT hs-cTnI assay. Mindray's hs-cTnI (CLIA) assay is an attractive alternative for diagnosis of myocardial infarction with a high level of accuracy and safety.


Asunto(s)
Síndrome Coronario Agudo , Infarto del Miocardio , Humanos , Masculino , Femenino , Troponina I , Sensibilidad y Especificidad , Infarto del Miocardio/diagnóstico , Síndrome Coronario Agudo/diagnóstico , Bioensayo , Biomarcadores , Troponina T
13.
Clin Chem Lab Med ; 2024 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-38738903

RESUMEN

OBJECTIVES: Heparin is a highly charged polysaccharide used as an anticoagulant to prevent blood coagulation in patients with presumed myocardial infarction and to prepare heparin plasma samples for laboratory tests. There are conflicting data regarding the effects of heparin on the measurement of cardiac isoforms of troponin I (cTnI) and troponin T (cTnT), which are used for the immunodiagnosis of acute myocardial infarction. In this study, we investigated the influence of heparin on the immunodetection of human cardiac troponins. METHODS: Gel filtration (GF) techniques and sandwich fluoroimmunoassay were performed. The regions of сTnI and cTnT that are affected by heparin were investigated with a panel of anti-cTnI and anti-cTnT monoclonal antibodies, specific to different epitopes. RESULTS: Heparin was shown to bind to the human cardiac full-size ternary troponin complex (ITC-complex) and free cTnT, which increased their apparent molecular weights in GF studies. Heparin did not bind to the low molecular weight ITC-complex and to binary cTnI-troponin С complex. We did not detect any sites on cTnI in the ITC-complex that were specifically affected by heparin. In contrast, cTnT regions limited to approximately 69-99, 119-138 and 145-164 amino acid residues (aar) in the ITC-complex and a region that lies approximately between 236 and 255 aar of free cTnT were prone to heparin influence. CONCLUSIONS: Heparin binds to the ITC-complex via cTnT, interacting with several sites on the N-terminal and/or central parts of the cTnT molecule, which might influence the immunodetection of analytes in human blood.

14.
Clin Chem Lab Med ; 2024 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-38801528

RESUMEN

OBJECTIVES: This study performed an analytical validation study of the Mindray high-sensitivity cardiac troponin I (hs-cTnI) assay addressing limit of blank (LoB), limit of detection (LoD), precision, linearity, analytical specificity and sex-specific 99th percentile upper reference limits. METHODS: LoB, LoD, precision, linearity and analytical specificity were studied according to Clinical and Laboratory Standards Institute. We used one reagent lot and one CL1200i analyzer. Skeletal troponin I and T, cardiac troponin T, troponin C, actin, tropomyosin, myosin light chain, myoglobin and creatine kinase (CK-MB) were studied for cross-reactivity. Interference with biotin was examined. Lithium heparin samples (one freeze thaw cycle) from healthy males and females were measured to determine the 99th percentiles by using the non-parametric method. Analyses were performed before and after excluding subjects with clinical conditions and/or increased surrogate biomarkers. RESULTS: The Mindray hs-cTnI assay met criteria to be considered as a hs-cTn assay. LoB and LoD was <0.1 ng/L and 0.1 ng/L, respectively. Repeatability had a coefficient of variation 1.2-3.8 %, and within-laboratory imprecision 1.7-5.0 %. The measuring interval ranged from 1.1 to 28,180 ng/L. The analytical specificity was clinically acceptable for the interferents studied. After exclusions, the 99th percentile URLs obtained were 10 ng/L overall, 5 ng/L for females and 12 ng/L for males. CONCLUSIONS: Analytical observations of the Mindray hs-cTnI assay demonstrated excellent LoB, LoD, precision, linearity and analytical specificity, that were in alignment with the manufacturer's claims and regulatory guidelines for hs-cTnI. The assay is suitable for clinical investigation for patient-oriented studies.

15.
Clin Chem Lab Med ; 62(6): 1158-1166, 2024 May 27.
Artículo en Inglés | MEDLINE | ID: mdl-38353154

RESUMEN

OBJECTIVES: To accurately evaluate non-ST-elevated acute cardiac syndrome (NSTE-ACS), the quality of high-sensitive cardiac troponin (hs-cTn) assays is of vital importance. The 2020 revision of the NSTE-ACS guideline includes clinical decision-limits (CDL's) to both rule-in and rule-out NSTE-ACS for most commercially available platforms, providing both 0/1 h and 0/2 h delta limits. Our study evaluated whether laboratories are able to meet the analytical performance specifications for imprecision (APS) for hs-cTnT. METHODS: Results from external quality assurance (EQA) in commutable samples were used to evaluate the current and historic performance of analyzers. The performance of analyzers that either passed or failed to comply with 0/1 h-APS were used on a real-world dataset of first hs-cTnT-values to simulate 10.000 samples of t=0, t=1 and t=2 h values with multiple delta's for all relevant CDL's. We compared the simulated values to the input values to obtain the percentage of aberrant results simulated. RESULTS: The majority of analyzers complies with APS for rule-in in 2022 (0/1 h: 90.4 % and 0/2 h: 100 %), compliance for the 0/1 h rule-out is still far from optimal (0/1 h: 30.7 %, 0/2 h: 75.4 %), with improving compliance over the past years (rule-in p=<0.0001, rule-out p=0.011, χ2). Whilst 0/1 h-APS-passing analyzers have a minute risk to falsely rule-out patients whom should be ruled-in (0.0001 %), failing performance increases this risk to 2.1 % upon using 0/1 h CDL's. Here, adopting 0/2 h CDL's is favorable (0.01 %). CONCLUSIONS: Laboratories that fail to meet hs-cTnT 0/1 h-APS should improve their performance to the required and achievable level. Until performance is reached clinics should adopt the 0/2 h CDL's.


Asunto(s)
Troponina T , Humanos , Troponina T/sangre , Troponina T/análisis , Síndrome Coronario Agudo/diagnóstico , Síndrome Coronario Agudo/sangre , Control de Calidad , Garantía de la Calidad de Atención de Salud , Guías de Práctica Clínica como Asunto
16.
Clin Chem Lab Med ; 2024 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-38669209

RESUMEN

OBJECTIVES: About 10 million individuals in USA presented annually in the emergency department (ED) with chest pain or with signs and symptoms of acute coronary syndrome (ACS). The advent of point of care (POC) devices, able to measure high sensitivity troponin, are a very interesting tool in the ED setting for its rapid turnaround time (<10 min). METHODS: The present study evaluates the diagnostic performance of the Atellica VTLi (Siemens) in real life setting using the clinical data derived from integrated diagnoses of emergency room staff and cardiologist and in comparison with standard laboratory hs-cTnT assay (Cobas 8000, Elecsys, Roche). 966 patients admitted to the emergency department of "G. Mazzini Hospital" in Teramo, Italy, from July 27, 2022, through June 09, 2023, were enrolled. RESULTS: The diagnostic performance of POC hs-cTnI was evaluated. An appropriate POC hs-cTnI threshold values <4 ng/L supplied a sensitivity and an NPV of 100 % (95 % CI: 99.5-100) in order to achieve rapid rule out for MI through a single measurement at patient presentation in the ED. Furthermore, a derivation POC hs-cTnI concentration >54 ng/L provided a specificity of 97.2 % (95 % CI: 95.9-98.1) and a PPV of 43.5 % (95 % CI: 40.3-46.7) for ruling in MI. CONCLUSIONS: This platform showed comparable diagnostic performance for myocardial infarction to the central laboratory. Our data suggest the possible use of the Atellica VTLi hs-cTnI POC assay either in emergency department of urban medical centre, either in rural hospital for triage and patient management.

17.
Br J Anaesth ; 132(4): 653-666, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38262855

RESUMEN

Assay-specific increases in circulating cardiac troponin are observed in 20-40% of patients after noncardiac surgery, depending on patient age, type of surgery, and comorbidities. Increased cardiac troponin is consistently associated with excess morbidity and mortality after noncardiac surgery. Despite these findings, the underlying mechanisms are unclear. The majority of interventional trials have been designed on the premise that ischaemic cardiac disease drives elevated perioperative cardiac troponin concentrations. We consider data showing that elevated circulating cardiac troponin after surgery could be a nonspecific marker of cardiomyocyte stress. Elevated concentrations of circulating cardiac troponin could reflect coordinated pathological processes underpinning organ injury that are not necessarily caused by ischaemia. Laboratory studies suggest that matching of coronary artery autoregulation and myocardial perfusion-contraction coupling limit the impact of systemic haemodynamic changes in the myocardium, and that type 2 ischaemia might not be the likeliest explanation for cardiac troponin elevation in noncardiac surgery. The perioperative period triggers multiple pathological mechanisms that might cause cardiac troponin to cross the sarcolemma. A two-hit model involving two or more triggers including systemic inflammation, haemodynamic strain, adrenergic stress, and autonomic dysfunction might exacerbate or initiate acute myocardial injury directly in the absence of cell death. Consideration of these diverse mechanisms is pivotal for the design and interpretation of interventional perioperative trials.


Asunto(s)
Infarto del Miocardio , Isquemia Miocárdica , Humanos , Infarto del Miocardio/etiología , Complicaciones Posoperatorias/diagnóstico , Isquemia Miocárdica/complicaciones , Miocardio , Troponina , Biomarcadores
18.
BMC Cardiovasc Disord ; 24(1): 260, 2024 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-38769516

RESUMEN

INTRODUCTION: Use of doxorubicin, an anthracycline chemotherapeutic agent has been associated with late-occurring cardiac toxicities. Detection of early-occurring cardiac effects of cancer chemotherapy is essential to prevent occurrence of adverse events including toxicity, myocardial dysfunction, and death. OBJECTIVE: To investigate the prevalence of elevated cardiac troponin T (cTnT) and associated factors of myocardial injury in children on doxorubicin cancer chemotherapy. METHODS: Design: A cross-sectional study. SETTING AND SUBJECTS: A hospital-based study conducted on children aged 1-month to 12.4-years who had a diagnosis of cancer and were admitted at Kenyatta National Hospital (KNH). INTERVENTIONS AND OUTCOMES: The patients underwent Echocardiography (ECHO) before their scheduled chemotherapy infusion. Twenty-four (24) hours after the chemotherapy infusion the patients had an evaluation of the serum cardiac troponin T (cTnT) and a repeat ECHO. Myocardial injury was defined as cTnT level > 0.014 ng/ml or a Fractional Shortening (FS) of < 29% on ECHO. RESULTS: One hundred (100) children were included in the final analysis. Thirty-two percent (32%) of the study population had an elevated cTnT. A cumulative doxorubicin dose of > 175 mg/m2 was significantly associated with and elevated cTnT (OR, 10.76; 95% CI, 1.18-97.92; p = 0.035). Diagnosis of nephroblastoma was also associated with an elevated cTnT (OR, 3.0; 95% CI, 1.23-7.26) but not statistically significant (p = 0.105). Nine percent (9%) of the participants had echocardiographic evidence of myocardial injury. CONCLUSION: When compared to echocardiography, elevated levels of cTnT showed a higher association with early-occurring chemotherapy-induced myocardial injury among children on cancer treatment at a tertiary teaching and referral hospital in Kenya.


Asunto(s)
Antibióticos Antineoplásicos , Biomarcadores , Cardiotoxicidad , Doxorrubicina , Neoplasias , Centros de Atención Terciaria , Troponina T , Humanos , Estudios Transversales , Masculino , Femenino , Doxorrubicina/efectos adversos , Niño , Kenia/epidemiología , Troponina T/sangre , Preescolar , Antibióticos Antineoplásicos/efectos adversos , Lactante , Neoplasias/tratamiento farmacológico , Neoplasias/sangre , Factores de Riesgo , Biomarcadores/sangre , Prevalencia , Factores de Tiempo , Regulación hacia Arriba , Cardiopatías/inducido químicamente , Cardiopatías/epidemiología , Cardiopatías/diagnóstico por imagen , Cardiopatías/diagnóstico , Cardiopatías/sangre , Factores de Edad , Medición de Riesgo , Ecocardiografía
19.
Environ Res ; 261: 119632, 2024 Jul 25.
Artículo en Inglés | MEDLINE | ID: mdl-39025350

RESUMEN

BACKGROUND: Cardiovascular consequences of phthalates exposure have been given increasing attention, but the association of phthalates with subclinical cardiovascular disease (CVD) was unknown. Accordingly, this study aimed to investigate the association between phthalates exposure and high-sensitivity cardiac troponin I (hs-cTnI), a marker of myocardial injury, which was detectable in the subclinical stage of CVD. METHODS: Participants aged 6 years or older with available urinary phthalates metabolites and serum hs-cTnI concentrations were included in the National Health and Nutrition Examination Survey 2003-2004 cycle. Multivariable linear regression and weighted quantiles sum (WQS) regression were used to assess the association of hs-cTnI with individual phthalates and their co-exposure. Di-2-ethylhexylphthalate (ΣDEHP), high-molecular-weight phthalate (ΣHMWP), and low-molecular-weight phthalate (ΣLMWP) were defined as the molecular sum of phthalates metabolites in urine. RESULTS: 2241 participants were finally included. The percent change of serum hs-cTnI concentrations related to per 1-standard deviation increase of logarithmic urinary phthalates concentrations was 3.4% (0.1-6.7, P = 0.04) for ΣDEHP, 3.6% (0.3-6.9, P = 0.03) for ΣHMWP, and 3.5% (0.2-6.8, P = 0.04) for ΣLMWP. Co-exposure to phthalates metabolites expressed as the WQS index also demonstrated a positive association with hs-cTnI. A similar association pattern was found in the population with no prior CVD. CONCLUSIONS: This study indicated the potential of phthalates to myocardial injury which may occur even before clinically apparent CVD was identified, emphasizing the significance of reducing phthalates in the prevention of CVD.

20.
Scand J Med Sci Sports ; 34(5): e14667, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38773919

RESUMEN

The relationship between exercise-induced troponin elevation and non-obstructive coronary artery disease (CAD) is unclear. This observational study assessed non-obstructive CAD's impact on exercise-induced cardiac Troponin I (cTnI) elevation in middle-aged recreational athletes. cTnI levels of 40 well-trained recreational athletes (73% males, 50 ± 9 years old) were assessed by a high-sensitive cTnI assay 24 h before, and at 3 and 24 h following two high-intensity exercises of different durations; a cardiopulmonary exercise test (CPET), and a 91-km mountain bike race. Workload was measured with power meters. Coronary computed tomography angiography was used to determine the presence or absence of non-obstructive (<50% obstruction) CAD. A total of 15 individuals had non-obstructive CAD (Atherosclerotic group), whereas 25 had no atherosclerosis (normal). There were higher post-exercise cTnI levels following the race compared with CPET, both at 3 h (77.0 (35.3-112.4) ng/L vs. 11.6 (6.4-22.5) ng/L, p < 0.001) and at 24 h (14.7 (6.7-16.3) vs. 5.0 (2.6-8.9) ng/L, p < 0.001). Absolute cTnI values did not differ among groups. Still, the association of cTnI response to power output was significantly stronger in the CAD versus Normal group both at 3 h post-exercise (Rho = 0.80, p < 0.001 vs. Rho = -0.20, p = 0.33) and 24-h post-exercise (Rho = 0.87, p < 0.001 vs. Rho = -0.13, p = 0.55). Exercise-induced cTnI elevation was strongly correlated with exercise workload in middle-aged athletes with non-obstructive CAD but not in individuals without CAD. This finding suggests that CAD influences the relationship between exercise workload and the cTnI response even without coronary artery obstruction.


Asunto(s)
Enfermedad de la Arteria Coronaria , Prueba de Esfuerzo , Ejercicio Físico , Troponina I , Humanos , Masculino , Persona de Mediana Edad , Enfermedad de la Arteria Coronaria/sangre , Femenino , Troponina I/sangre , Ejercicio Físico/fisiología , Adulto , Ciclismo/fisiología , Carga de Trabajo , Angiografía por Tomografía Computarizada , Atletas , Angiografía Coronaria
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA