Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 781
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
Magn Reson Med ; 91(5): 1951-1964, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38181169

RESUMEN

PURPOSE: Simultaneous PET-MRI improves inflammatory cardiac disease diagnosis. However, challenges persist in respiratory motion and mis-registration between free-breathing 3D PET and 2D breath-held MR images. We propose a free-breathing non-rigid motion-compensated 3D T2 -mapping sequence enabling whole-heart myocardial tissue characterization in a hybrid 3T PET-MR system and provides non-rigid respiratory motion fields to correct also simultaneously acquired PET data. METHODS: Free-breathing 3D whole-heart T2 -mapping was implemented on a hybrid 3T PET-MRI system. Three datasets were acquired with different T2 -preparation modules (0, 28, 55 ms) using 3-fold undersampled variable-density Cartesian trajectory. Respiratory motion was estimated via virtual 3D image navigators, enabling multi-contrast non-rigid motion-corrected MR reconstruction. T2 -maps were computed using dictionary-matching. Approach was tested in phantom, 8 healthy subjects, 14 MR only and 2 PET-MR patients with suspected cardiac disease and compared with spin echo reference (phantom) and clinical 2D T2 -mapping (in-vivo). RESULTS: Phantom results show a high correlation (R2 = 0.996) between proposed approach and gold standard 2D T2 mapping. In-vivo 3D T2 -mapping average values in healthy subjects (39.0 ± 1.4 ms) and patients (healthy tissue) (39.1 ± 1.4 ms) agree with conventional 2D T2 -mapping (healthy = 38.6 ± 1.2 ms, patients = 40.3 ± 1.7 ms). Bland-Altman analysis reveals bias of 1.8 ms and 95% limits of agreement (LOA) of -2.4-6 ms for healthy subjects, and bias of 1.3 ms and 95% LOA of -1.9 to 4.6 ms for patients. CONCLUSION: Validated efficient 3D whole-heart T2 -mapping at hybrid 3T PET-MRI provides myocardial inflammation characterization and non-rigid respiratory motion fields for simultaneous PET data correction. Comparable T2 values were achieved with both 3D and 2D methods. Improved image quality was observed in the PET images after MR-based motion correction.


Asunto(s)
Miocarditis , Miocardio , Humanos , Imagen por Resonancia Magnética , Movimiento (Física) , Imagenología Tridimensional/métodos , Tomografía de Emisión de Positrones , Corazón/diagnóstico por imagen , Fantasmas de Imagen
2.
Magn Reson Med ; 2024 Aug 11.
Artículo en Inglés | MEDLINE | ID: mdl-39129209

RESUMEN

PURPOSE: Echo modulation curve (EMC) modeling enables accurate quantification of T2 relaxation times in multi-echo spin-echo (MESE) imaging. The standard EMC-T2 mapping framework, however, requires sufficient echoes and cumbersome pixel-wise dictionary-matching steps. This work proposes a deep learning version of EMC-T2 mapping, called DeepEMC-T2 mapping, to efficiently estimate accurate T2 maps from fewer echoes. METHODS: DeepEMC-T2 mapping was developed using a modified U-Net to estimate both T2 and proton density (PD) maps directly from MESE images. The network implements several new features to improve the accuracy of T2/PD estimation. A total of 67 MESE datasets acquired in axial orientation were used for network training and evaluation. An additional 57 datasets acquired in coronal orientation with different scan parameters were used to evaluate the generalizability of the framework. The performance of DeepEMC-T2 mapping was evaluated in seven experiments. RESULTS: Compared to the reference, DeepEMC-T2 mapping achieved T2 estimation errors from 1% to 11% and PD estimation errors from 0.4% to 1.5% with ten/seven/five/three echoes, which are more accurate than standard EMC-T2 mapping. By incorporating datasets acquired with different scan parameters and orientations for joint training, DeepEMC-T2 exhibits robust generalizability across varying imaging protocols. Increasing the echo spacing and including longer echoes improve the accuracy of parameter estimation. The new features proposed in DeepEMC-T2 mapping all enabled more accurate T2 estimation. CONCLUSIONS: DeepEMC-T2 mapping enables simplified, efficient, and accurate T2 quantification directly from MESE images without dictionary matching. Accurate T2 estimation from fewer echoes allows for increased volumetric coverage and/or higher slice resolution without prolonging total scan times.

3.
Magn Reson Med ; 92(3): 1064-1078, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38726772

RESUMEN

PURPOSE: This study aims to develop and evaluate a novel cardiovascular MR sequence, MyoFold, designed for the simultaneous quantifications of myocardial tissue composition and wall motion. METHODS: MyoFold is designed as a 2D single breathing-holding sequence, integrating joint T1/T2 mapping and cine imaging. The sequence uses a 2-fold accelerated balanced SSFP (bSSFP) for data readout and incorporates electrocardiogram synchronization to align with the cardiac cycle. MyoFold initially acquires six single-shot inversion-recovery images, completed during the diastole of six successive heartbeats. T2 preparation (T2-prep) is applied to introduce T2 weightings for the last three images. Subsequently, over the following six heartbeats, segmented bSSFP is performed for the movie of the entire cardiac cycle, synchronized with an electrocardiogram. A neural network trained using numerical simulations of MyoFold is used for T1 and T2 calculations. MyoFold was validated through phantom and in vivo experiments, with comparisons made against MOLLI, SASHA, T2-prep bSSFP, and the conventional cine. RESULTS: In phantom studies, MyoFold exhibited a 10% overestimation in T1 measurements, whereas T2 measurements demonstrated high accuracy. In vivo experiments revealed that MyoFold T1 had comparable accuracy to SASHA and precision similar to MOLLI. MyoFold demonstrated good agreement with T2-prep bSSFP in myocardial T2 measurements. No significant differences were observed in the quantification of left-ventricle wall thickness and function between MyoFold and the conventional cine. CONCLUSION: MyoFold presents as a rapid, simple, and multitasking approach for quantitative cardiovascular MR examinations, offering simultaneous assessment of tissue composition and wall motion. The sequence's multitasking capabilities make it a promising tool for comprehensive cardiac evaluations in clinical settings.


Asunto(s)
Corazón , Imagen por Resonancia Cinemagnética , Fantasmas de Imagen , Adulto , Femenino , Humanos , Masculino , Algoritmos , Electrocardiografía , Corazón/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Cinemagnética/métodos , Miocardio , Reproducibilidad de los Resultados
4.
Magn Reson Med ; 92(3): 1138-1148, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38730565

RESUMEN

PURPOSE: To develop a highly accelerated multi-echo spin-echo method, TEMPURA, for reducing the acquisition time and/or increasing spatial resolution for kidney T2 mapping. METHODS: TEMPURA merges several adjacent echoes into one k-space by either combining independent echoes or sharing one echo between k-spaces. The combined k-space is reconstructed based on compressed sensing theory. Reduced flip angles are used for the refocusing pulses, and the extended phase graph algorithm is used to correct the effects of indirect echoes. Two sequences were developed: a fast breath-hold sequence; and a high-resolution sequence. The performance was evaluated prospectively on a phantom, 16 healthy subjects, and two patients with different types of renal tumors. RESULTS: The fast TEMPURA method reduced the acquisition time from 3-5 min to one breath-hold (18 s). Phantom measurements showed that fast TEMPURA had a mean absolute percentage error (MAPE) of 8.2%, which was comparable to a standardized respiratory-triggered sequence (7.4%), but much lower than a sequence accelerated by purely k-t undersampling (21.8%). High-resolution TEMPURA reduced the in-plane voxel size from 3 × 3 to 1 × 1 mm2, resulting in improved visualization of the detailed anatomical structure. In vivo T2 measurements demonstrated good agreement (fast: MAPE = 1.3%-2.5%; high-resolution: MAPE = 2.8%-3.3%) and high correlation coefficients (fast: R = 0.85-0.98; high-resolution: 0.82-0.96) with the standardized method, outperforming k-t undersampling alone (MAPE = 3.3-4.5%, R = 0.57-0.59). CONCLUSION: TEMPURA provides fast and high-resolution renal T2 measurements. It has the potential to improve clinical throughput and delineate intratumoral heterogeneity and tissue habitats at unprecedented spatial resolution.


Asunto(s)
Algoritmos , Neoplasias Renales , Riñón , Fantasmas de Imagen , Humanos , Neoplasias Renales/diagnóstico por imagen , Riñón/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Femenino , Adulto , Masculino , Interpretación de Imagen Asistida por Computador/métodos , Reproducibilidad de los Resultados , Persona de Mediana Edad , Aumento de la Imagen/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Contencion de la Respiración
5.
Magn Reson Med ; 91(6): 2532-2545, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38321592

RESUMEN

PURPOSE: The increasing incidence of kidney diseases is a global concern, and current biomarkers and treatments are inadequate. Changes in renal tubule luminal volume fraction (TVF) serve as a rapid biomarker for kidney disease and improve understanding of renal (patho)physiology. This study uses the amplitude of the long T2 component as a surrogate for TVF in rats, by applying multiexponential analysis of the T2-driven signal decay to examine micromorphological changes in renal tissue. METHODS: Simulations were conducted to identify a low mean absolute error (MAE) protocol and an accelerated protocol customized for the in vivo study of T2 mapping of the rat kidney at 9.4 T. We then validated our bi-exponential approach in a phantom mimicking the relaxation properties of renal tissue. This was followed by a proof-of-principle demonstration using in vivo data obtained during a transient increase of renal pelvis and tubular pressure. RESULTS: Using the low MAE protocol, our approach achieved an accuracy of MAE < 1% on the mechanical phantom. The T2 mapping protocol customized for in vivo study achieved an accuracy of MAE < 3%. Transiently increasing pressure in the renal pelvis and tubules led to significant changes in TVF in renal compartments: ΔTVFcortex = 4.9%, ΔTVFouter_medulla = 4.5%, and ΔTVFinner_medulla = -14.6%. CONCLUSION: These results demonstrate that our approach is promising for research into quantitative assessment of renal TVF in in vivo applications. Ultimately, these investigations have the potential to help reveal mechanism in acute renal injury that may lead to chronic kidney disease, which will support research into renal disorders.


Asunto(s)
Lesión Renal Aguda , Insuficiencia Renal Crónica , Ratas , Animales , Imagen por Resonancia Magnética/métodos , Riñón/diagnóstico por imagen , Túbulos Renales/diagnóstico por imagen
6.
Magn Reson Med ; 91(5): 1936-1950, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38174593

RESUMEN

PURPOSE: Widely used conventional 2D T2 * approaches that are based on breath-held, electrocardiogram (ECG)-gated, multi-gradient-echo sequences are prone to motion artifacts in the presence of incomplete breath holding or arrhythmias, which is common in cardiac patients. To address these limitations, a 3D, non-ECG-gated, free-breathing T2 * technique that enables rapid whole-heart coverage was developed and validated. METHODS: A continuous random Gaussian 3D k-space sampling was implemented using a low-rank tensor framework for motion-resolved 3D T2 * imaging. This approach was tested in healthy human volunteers and in swine before and after intravenous administration of ferumoxytol. RESULTS: Spatial-resolution matched T2 * images were acquired with 2-3-fold reduction in scan time using the proposed T2 * mapping approach relative to conventional T2 * mapping. Compared with the conventional approach, T2 * images acquired with the proposed method demonstrated reduced off-resonance and flow artifacts, leading to higher image quality and lower coefficient of variation in T2 *-weighted images of the myocardium of swine and humans. Mean myocardial T2 * values determined using the proposed and conventional approaches were highly correlated and showed minimal bias. CONCLUSION: The proposed non-ECG-gated, free-breathing, 3D T2 * imaging approach can be performed within 5 min or less. It can overcome critical image artifacts from undesirable cardiac and respiratory motion and bulk off-resonance shifts at the heart-lung interface. The proposed approach is expected to facilitate faster and improved cardiac T2 * mapping in those with limited breath-holding capacity or arrhythmias.


Asunto(s)
Corazón , Miocardio , Humanos , Animales , Porcinos , Corazón/diagnóstico por imagen , Respiración , Contencion de la Respiración , Imagen por Resonancia Cinemagnética/métodos , Imagen por Resonancia Magnética , Imagenología Tridimensional/métodos
7.
Magn Reson Med ; 92(4): 1511-1524, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38872384

RESUMEN

PURPOSE: To develop and validate a highly efficient motion compensated free-breathing isotropic resolution 3D whole-heart joint T1/T2 mapping sequence with anatomical water/fat imaging at 0.55 T. METHODS: The proposed sequence takes advantage of shorter T1 at 0.55 T to acquire three interleaved water/fat volumes with inversion-recovery preparation, no preparation, and T2 preparation, respectively. Image navigators were used to facilitate nonrigid motion-compensated image reconstruction. T1 and T2 maps were jointly calculated by a dictionary matching method. Validations were performed with simulation, phantom, and in vivo experiments on 10 healthy volunteers and 1 patient. The performance of the proposed sequence was compared with conventional 2D mapping sequences including modified Look-Locker inversion recovery and T2-prepared balanced steady-SSFP sequence. RESULTS: The proposed sequence has a good T1 and T2 encoding sensitivity in simulation, and excellent agreement with spin-echo reference T1 and T2 values was observed in a standardized T1/T2 phantom (R2 = 0.99). In vivo experiments provided good-quality co-registered 3D whole-heart T1 and T2 maps with 2-mm isotropic resolution in a short scan time of about 7 min. For healthy volunteers, left-ventricle T1 mean and SD measured by the proposed sequence were both comparable with those of modified Look-Locker inversion recovery (640 ± 35 vs. 630 ± 25 ms [p = 0.44] and 49.9 ± 9.3 vs. 54.4 ± 20.5 ms [p = 0.42]), whereas left-ventricle T2 mean and SD measured by the proposed sequence were both slightly lower than those of T2-prepared balanced SSFP (53.8 ± 5.5 vs. 58.6 ± 3.3 ms [p < 0.01] and 5.2 ± 0.9 vs. 6.1 ± 0.8 ms [p = 0.03]). Myocardial T1 and T2 in the patient measured by the proposed sequence were in good agreement with conventional 2D sequences and late gadolinium enhancement. CONCLUSION: The proposed sequence simultaneously acquires 3D whole-heart T1 and T2 mapping with anatomical water/fat imaging at 0.55 T in a fast and efficient 7-min scan. Further investigation in patients with cardiovascular disease is now warranted.


Asunto(s)
Tejido Adiposo , Imagenología Tridimensional , Fantasmas de Imagen , Humanos , Imagenología Tridimensional/métodos , Masculino , Tejido Adiposo/diagnóstico por imagen , Adulto , Corazón/diagnóstico por imagen , Reproducibilidad de los Resultados , Algoritmos , Femenino , Imagen por Resonancia Magnética/métodos , Respiración , Agua Corporal/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Voluntarios Sanos
8.
Magn Reson Med ; 91(5): 2010-2027, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38098428

RESUMEN

PURPOSE: To develop a deep image prior (DIP) reconstruction for B1 + -corrected 2D cine MR fingerprinting (MRF). METHODS: The proposed method combines low-rank (LR) modeling with a DIP to generate cardiac phase-resolved parameter maps without motion correction, employing self-supervised training to enforce consistency with undersampled spiral k-space data. Two implementations were tested: one approach (DIP) for cine T1 , T2 , and M0 mapping, and a second approach (DIP with effective B1 + estimation [DIP-B1]) that also generated an effective B1 + map to correct for errors due to RF transmit inhomogeneities, through-plane motion, and blood flow. Cine MRF data were acquired in 14 healthy subjects and four reconstructions were compared: LR, low-rank motion-corrected (LRMC), DIP, and DIP-B1. Results were compared to diastolic ECG-triggered MRF, MOLLI, and T2 -prep bSSFP. Additionally, bright-blood and dark-blood images calculated from cine MRF maps were used to quantify ventricular function and compared to reference cine measurements. RESULTS: DIP and DIP-B1 outperformed other cine MRF reconstructions with improved noise suppression and delineation of high-resolution details. Within-segment variability in the myocardium (reported as the coefficient of variation for T1 /T2 ) was lowest for DIP-B1 (2.3/8.3%) followed by DIP (2.7/8.7%), LRMC (3.5/10.5%), and LR (15.3/39.6%). Spatial homogeneity improved with DIP-B1 having the lowest intersegment variability (2.6/4.1%). The mean bias in ejection fraction was -1.1% compared to reference cine scans. CONCLUSION: A DIP reconstruction for 2D cine MRF enabled cardiac phase-resolved mapping of T1 , T2 , M0 , and the effective B1 + with improved noise suppression and precision compared to LR and LRMC.


Asunto(s)
Corazón , Imagen por Resonancia Magnética , Humanos , Imagen por Resonancia Magnética/métodos , Corazón/diagnóstico por imagen , Miocardio , Procesamiento de Imagen Asistido por Computador/métodos , Voluntarios Sanos , Fantasmas de Imagen
9.
Magn Reson Med ; 91(5): 2089-2103, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38156822

RESUMEN

PURPOSE: To investigate whether a T2 inter-slice variation could occur when a multi-slice multi-echo spin echo (MESE) sequence is used for image acquisition and to propose an enhanced method for reconstructing T2 maps that can effectively address and correct these variations. METHODS: Bloch simulations were performed accounting for the direct saturation effect to evaluate magnetization changes in multi-slice 2D MESE sequence. Experimental phantom scans were performed to validate these simulations. An improved version of the dictionary-based reconstruction approach was proposed, enabling the creation of a multi-slice dictionary of echo modulation curves (EMC). The corresponding method has been assayed considering inter-slice T2 variation with phantoms and in lower leg. RESULTS: Experimental and numerical study illustrate that direct saturation leads to a bias of EMCs. This bias during the T2 maps reconstructions using original single-slice EMC-dictionary method led to inter-slice T2 variation of 2.03% in average coefficient of variation (CV) in agarose phantoms, and up to 2.8% in vivo (for TR = 2 s, slice gap = 0%). A reduction of CV was observed when increasing the gap up to 100% (0.36% in phantoms, and up to 1.5% in vivo) or increasing TR up to 4 s (0.76% in phantoms, and up to 1.9% in vivo). Matching the multi-slice experimental data with multi-slice dictionaries provided a reduced CV of 0.54% in phantoms and up to 2.3% in vivo. CONCLUSION: T2 values quantified from multi-slice MESE images using single-slice dictionaries are biased. A dedicated multi-slice EMC method providing the appropriate dictionaries can reduce the inter-slice T2 variation.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Imagen por Resonancia Magnética/métodos , Reproducibilidad de los Resultados , Fantasmas de Imagen , Procesamiento de Imagen Asistido por Computador/métodos , Encéfalo/diagnóstico por imagen
10.
J Magn Reson Imaging ; 59(3): 865-876, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37316971

RESUMEN

BACKGROUND: In most cases, lateral patellar dislocation (LPD) is accompanied by chondral injury and may initiate gradual degeneration of patellar cartilage, which might be detected with a T2 mapping, a well-established method for cartilage lesions assessment. PURPOSE: To examine short-term consequences of single first-time LPD in teenagers by T2 mapping of the patellar-cartilage state. STUDY TYPE: Prospective. POPULATION: 95 patients (mean age: 15.1 ± 2.3; male/female: 46/49) with first-time, complete, traumatic LPD and 51 healthy controls (mean age: 14.7 ± 2.2, male/female: 29/22). FIELD STRENGTH/SEQUENCE: 3.0 T; axial T2 mapping acquired using a 2D turbo spin-echo sequence. ASSESSMENT: MRI examination was conducted 2-4 months after first LPD. T2 values were calculated in manually segmented cartilage area via averaging over three middle level slices in six cartilage regions: deep, intermediate, superficial layers, and medial lateral parts. STATISTICAL TESTS: ANOVA analysis with Tukey's multiple comparison test, one-vs.-rest logistic regression analysis. The threshold of significance was set at P < 0.05. RESULTS: In lateral patellar cartilage, a significant increase in T2 values was found in deep and intermediate layers in both patient groups with mild (deep: 34.7 vs. 31.3 msec, intermediate: 38.7 vs. 34.6 msec, effect size = 0.55) and severe (34.8 vs. 31.3 msec, 39.1 vs. 34.6 msec, 0.55) LPD consequences as compared to controls. In the medial facet, only severe cartilage damage showed significant prolongation of T2 times in the deep layer (34.3 vs. 30.7 msec, 0.55). No significant changes in T2 values were found in the lateral superficial layer (P = 0.99), whereas mild chondromalacia resulted in a significant decrease of T2 in the medial superficial layer (41.0 vs. 43.8 msec, 0.55). DATA CONCLUSION: The study revealed substantial difference in T2 changes after LPD between medial and lateral areas of patellar cartilage. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY STAGE: 2.


Asunto(s)
Enfermedades de los Cartílagos , Cartílago Articular , Luxación de la Rótula , Adolescente , Humanos , Masculino , Femenino , Niño , Luxación de la Rótula/complicaciones , Luxación de la Rótula/diagnóstico , Luxación de la Rótula/patología , Estudios Prospectivos , Rótula , Imagen por Resonancia Magnética/métodos , Cartílago Articular/patología , Enfermedades de los Cartílagos/complicaciones
11.
J Magn Reson Imaging ; 2024 May 04.
Artículo en Inglés | MEDLINE | ID: mdl-38703134

RESUMEN

BACKGROUND: Cartilage T2 can detect joints at risk of developing osteoarthritis. The quantitative double-echo steady state (qDESS) sequence is attractive for knee cartilage T2 mapping because of its acquisition time of under 5 minutes. Understanding the reproducibility errors associated with qDESS T2 is essential to profiling the technical performance of this biomarker. PURPOSE: To examine the combined acquisition and segmentation reproducibility of knee cartilage qDESS T2 using two different regional analysis schemes: 1) manual segmentation of subregions loaded during common activities and 2) automatic subregional segmentation. STUDY TYPE: Prospective. SUBJECTS: 11 uninjured participants (age: 28 ± 3 years; 8 (73%) female). FIELD STRENGTH/SEQUENCE: 3-T, qDESS. ASSESSMENT: Test-retest T2 maps were acquired twice on the same day and with a 1-week interval between scans. For each acquisition, average cartilage T2 was calculated in four manually segmented regions encompassing tibiofemoral contact areas during common activities and 12 automatically segmented regions from the deep-learning open-source framework for musculoskeletal MRI analysis (DOSMA) encompassing medial and lateral anterior, central, and posterior tibiofemoral regions. Test-retest T2 values from matching regions were used to evaluate reproducibility. STATISTICAL TESTS: Coefficients of variation (%CV), root-mean-square-average-CV (%RMSA-CV), and intraclass correlation coefficients (ICCs) assessed test-retest T2 reproducibility. The median of test-retest standard deviations was used for T2 precision. Bland-Altman (BA) analyses examined test-retest biases. The smallest detectable difference (SDD) was defined as the BA limit of agreement of largest magnitude. Significance was accepted for P < 0.05. RESULTS: All cartilage regions across both segmentation schemes demonstrated intraday and interday qDESS T2 CVs and RMSA-CVs of ≤5%. T2 ICC values >0.75 were observed in the majority of regions but were more variable in interday tibial comparisons. Test-retest T2 precision was <1.3 msec. The T2 SDD was 3.8 msec. DATA CONCLUSION: Excellent CV and RMSA-CV reproducibility may suggest that qDESS T2 increases or decreases >5% (3.8 msec) could represent changes to cartilage composition. TECHNICAL EFFICACY: Stage 2.

12.
J Magn Reson Imaging ; 59(3): 825-834, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37338016

RESUMEN

BACKGROUND: Few studies assessed myocardial inflammation using Cardiovascular Magnetic Resonance Imaging in Kawasaki disease (KD) patients. PURPOSE: To quantify myocardial edema in KD patients using T2 mapping and explore the independent predictors of T2 values. STUDY TYPE: Prospective. SUBJECTS: Ninety KD patients including 40 in acute phase (26 males, 65.0%) and 50 in chronic phase (34 males, 68.0%). Thirty-one healthy volunteers (21 males, 70.0%). FIELD STRENGTH/SEQUENCE: 3.0 T T2-weighted Turbo Spin Echo-Short Time of Inversion Recovery sequence, True fast imaging with steady precession flash sequence and fast low-angle shot 3D spoiled gradient echo sequence. ASSESSMENT: T2 values were compared among KD groups and controls. STATISTICAL TEST: Student's t test and Fisher's exact test; One-way analysis of variance; Pearson correlation analysis; Receiver operating curve analysis; Multivariable linear regression. RESULTS: Global T2 value of KD patients in acute phase was the highest, followed by those of chronic-phase patients and controls (38.83 ± 2.41 msec vs. 37.55 ± 2.28 msec vs. 36.05 ± 1.64 msec). Regional T2 values showed a same trend. There were no significant differences in global and regional T2 values between KD patients with and without coronary artery (CA) dilation, no matter in acute or chronic phase (all KD patients: P = 0.51, 0.51, 0.53, 0.72; acute KD: P = 0.61, 0.37, 0.33, 0.83; chronic KD: P = 0.65, 0.79, 0.62, 0.79). No significant difference was observed in global T2 values between KD patients with Z score > 5.0 and 2.0 < Z score ≤ 5.0 (P = 0.65). Multivariate analysis demonstrated that stage of disease (ß = -0.123) and heart rate (ß = 0.280) were independently associated with global T2 values. DATA CONCLUSION: The degree of myocardial edema was more severe in acute-phase than in chronic-phase KD patients. Myocardial edema persists in patients regardless of the existence or degree of CA dilation. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 2.


Asunto(s)
Síndrome Mucocutáneo Linfonodular , Masculino , Niño , Humanos , Estudios Prospectivos , Miocardio/patología , Imagen por Resonancia Magnética/métodos , Edema
13.
J Magn Reson Imaging ; 2024 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-38380700

RESUMEN

BACKGROUND: T2 mapping is valuable to evaluate pathophysiology in kidney disease. However, variations in T2 relaxation time measurements across MR scanners and vendors may occur requiring additional correction. PURPOSE: To harmonize renal T2 measurements between MR vendor platforms, and use an extended-phase-graph-based fitting method ("StimFit") to correct stimulated echoes and reduce between-vendor variations. STUDY TYPE: Prospective. SUBJECTS: 8 healthy "travelling" volunteers (37.5% female, 32 ± 6 years) imaged on four MRI systems across three vendors at four sites, 10 healthy volunteers (50% female, 32 ± 8 years) scanned multiple times on a given MR scanner for repeatability evaluation. ISMRM/NIST system phantom scanned for evaluation of T2 accuracy. FIELD STRENGTH/SEQUENCE: 3T, multiecho spin-echo sequence. ASSESSMENT: T2 images fit using conventional monoexponential fitting and "StimFit." Mean absolute percentage error (MAPE) of phantom measurements with reference T2 values. Average cortex and medulla T2 values compared between MR vendors, with masks obtained from T2 -weighted images and T1 maps. Full-width-at-half-maximum (FWHM) T2 distributions to evaluate local homogeneity of measurements. STATISTICAL TESTS: Coefficient of variation (CV), linear mixed-effects model, analysis of variance, student's t-tests, Bland-Altman plots, P-value <0.05 considered statistically significant. RESULTS: In the ISMRM/NIST phantom, "StimFit" reduced the MAPE from 4.9%, 9.1%, 24.4%, and 18.1% for the four sites (three vendors) to 3.3%, 3.0%, 6.6%, and 4.1%, respectively. In vivo, there was a significant difference in kidney T2 measurements between vendors using a monoexponential fit, but not with "StimFit" (P = 0.86 and 0.92, cortex and medulla, respectively). The intervendor CVs of T2 measures were reduced from 8.0% to 2.6% (cortex) and 7.1% to 2.8% (medulla) with StimFit, resulting in no significant differences for the CVs of intravendor repeat acquisitions (P = 0.13 and 0.05). "StimFit" significantly reduced the FWHM of T2 distributions in the cortex and whole kidney. DATA CONCLUSION: Stimulated-echo correction reduces renal T2 variation across MR vendor platforms. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY: Stage 1.

14.
J Magn Reson Imaging ; 2024 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-38708838

RESUMEN

BACKGROUND: Chronic kidney disease (CKD) is associated with increased, and early cardiovascular disease risk. Changes in hemodynamics within the left ventricle (LV) respond to cardiac remodeling. The LV hemodynamics in nondialysis CKD patients are not clearly understood. PURPOSE: To use four-dimensional blood flow MRI (4D flow MRI) to explore changes in LV kinetic energy (KE) and the relationship between LV KE and LV remodeling in CKD patients. STUDY TYPE: Retrospective. POPULATION: 98 predialysis CKD patients (Stage 3: n = 21, stage 4: n = 21, and stage 5: n = 56) and 16 age- and sex-matched healthy controls. FIELD STRENGTH/SEQUENCE: 3.0 T/balanced steady-state free precession (SSFP) cine sequence, 4D flow MRI with a fast field echo sequence, T1 mapping with a modified Look-Locker SSFP sequence, and T2 mapping with a gradient recalled and spin echo sequence. ASSESSMENT: Demographic characteristics (age, sex, height, weight, blood pressure, heart rate, aortic regurgitation, and mitral regurgitation) and laboratory data (eGFR, Creatinine, hemoglobin, ferritin, transferrin saturation, potassium, and carbon dioxide bonding capacity) were extracted from patient records. Myocardial T1, T2, LV ejection fraction, end diastolic volume (EDV), end systolic volume, LV flow components (direct flow, delayed ejection, retained inflow, and residual volume) and KE parameters (peak systolic, systolic, diastolic, peak E-wave, peak A-wave, E/A ratio, and global) were assessed. The KE parameters were normalized to EDV (KEiEDV). Parameters were compared between disease stage in CKD patients, and between CKD patients and healthy controls. STATISTICAL TESTS: Differences in clinical and imaging parameters between groups were compared using one-way ANOVA, Kruskal Walls and Mann-Whitney U tests, chi-square test, and Fisher's exact test. Pearson or Spearman's correlation coefficients and multiple linear regression analysis were used to compare the correlation between LV KE and other clinical and functional parameters. A P-value of <0.05 was considered significant. RESULTS: Compared with healthy controls, peak systolic (24.76 ± 5.40 µJ/mL vs. 31.86 ± 13.18 µJ/mL), systolic (11.62 ± 2.29 µJ/mL vs. 15.27 ± 5.10 µJ/mL), diastolic (7.95 ± 1.92 µJ/mL vs. 13.33 ± 5.15 µJ/mL), peak A-wave (15.95 ± 4.86 µJ/mL vs. 31.98 ± 14.51 µJ/mL), and global KEiEDV (9.40 ± 1.64 µJ/mL vs. 14.02 ± 4.14 µJ/mL) were significantly increased and the KEiEDV E/A ratio (1.16 ± 0.67 vs. 0.69 ± 0.53) was significantly decreased in CKD patients. As the CKD stage progressed, both diastolic KEiEDV (10.45 ± 4.30 µJ/mL vs. 12.28 ± 4.85 µJ/mL vs. 14.80 ± 5.06 µJ/mL) and peak E-wave KEiEDV (15.30 ± 7.06 µJ/mL vs. 14.69 ± 8.20 µJ/mL vs. 19.33 ± 8.29 µJ/mL) increased significantly. In multiple regression analysis, global KEiEDV (ß* = 0.505; ß* = 0.328), and proportion of direct flow (ß* = -0.376; ß* = -0.410) demonstrated an independent association with T1 and T2 times. DATA CONCLUSION: 4D flow MRI-derived LV KE parameters show altered LV adaptations in CKD patients and correlate independently with T1 and T2 mapping that may represent myocardial fibrosis and edema. TECHNICAL EFFICACY: Stage 3.

15.
J Magn Reson Imaging ; 2024 Mar 14.
Artículo en Inglés | MEDLINE | ID: mdl-38483105

RESUMEN

BACKGROUND: Quantification of the T2 signal by means of T2 mapping in acute pancreatitis (AP) has the potential to quantify the parenchymal edema. Quantitative T2 mapping may overcome the limitations of previously reported scoring systems for reliable assessment of AP. PURPOSE: To evaluate MR-derived pancreatic T2 mapping values in AP and correlate them with markers of disease severity. STUDY TYPE: Prospective single-center study. POPULATION: 76 adults with AP (20-91 years, females/males: 39/37). FIELD STRENGTH/SEQUENCE: Fat suppressed multiecho spin-echo prototype sequence to quantify T2 signal at 3T MRI. ASSESSMENT: The severity of AP was assessed clinically, biologically, and by contrast-enhanced CT (CECT) performed 48-72 hours after symptom onset. MRI was then performed ≤24 hours after CT. Two readers blinded to any clinical information independently evaluated the T2 values by placing three regions of interest inside the pancreatic head, body, and tail on the T2 mapping MR sequence. Results were compared with corresponding CECT images as the standard and clinical severity parameters, using the length of hospital stay as our primary endpoint. STATISTICAL TESTS: Continuous variables were compared using the Spearman's rank correlation coefficient, analysis of variance (ANOVA) or Student's t-test. RESULTS: T2 values significantly correlated with the length of hospital stay (rs (74) = 0.29), CT severity index (CTSI) (rs (73) = 0.61; CTSI 0-3: 72 ± 14 msec, CTSI 4-10: 88 ± 15), intensive care unit (ICU) admission (t(2.77) = -3.41) and presence of organ failure (t(6.72) = -3.42), whereas the CTSI and Ranson score were not significantly related with ICU admission (CTSI: P = 0.24; Ranson score: P = 0.24) and organ failure (CTSI: P = 0.11; Ranson score P = 0.11). CONCLUSION: T2 mapping correlates with AP severity parameters and is useful for assessing the severity of AP with higher sensitivity than the usual clinical and radiological scoring systems. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY: Stage 2.

16.
J Magn Reson Imaging ; 2024 Feb 04.
Artículo en Inglés | MEDLINE | ID: mdl-38311966

RESUMEN

BACKGROUND: Myocardial injury is common in end-stage renal disease (ESRD) patients, but the presence and severity of myocardial injury in different left ventricular (LV) phenotypes were still not fully explored. PURPOSE: To evaluate myocardial tissue characteristics and deformation in ESRD patients on peritoneal dialysis separated into normal geometry, concentric remodeling, concentric left ventricular hypertrophy (LVH) and eccentric LVH patterns by multiparametric cardiac MRI. STUDY TYPE: Prospective. POPULATION: A total of 142 subjects, including 102 on peritoneal dialysis (69 males) and 40 healthy controls (27 males). FIELD STRENGTH/SEQUENCE: At 3.0 T, cine sequence, T1 mapping and T2 mapping. ASSESSMENT: LV mass index and LV remodeling index were used to create four subgroups with normal geometry, concentric remodeling, concentric LVH, and eccentric LVH. LV function, strain and strain rate, myocardial native T1 and T2 were measured. STATISTICAL TESTS: Descriptive statistics, analysis of variance and analysis of covariance, Pearson/Spearman correlation, stepwise regression, and intraclass correlation coefficient. P-value <0.05 was considered statistically significant. RESULTS: Even in normal geometry, LV strain parameters still diminished compared with the controls (global radial strain: 30.5 ± 7.7% vs. 37.1 ± 7.9%; global circumferential strain: -18.2 ± 2.6% vs. -20.6 ± 2.2%; global longitudinal strain: -13.3 ± 2.5% vs. -16.0 ± 2.8%). Eccentric LVH had significantly lower global circumferential systolic strain rate than concentric LVH (-0.82 ± 0.21%/- second vs. -0.96 ± 0.20%/- second). Compared with the controls, the four subgroups all revealed elevated native T1 and T2, especially in eccentric LVH, while concentric remodeling had the least changes including native T1, T2, and LV ejection fraction. After adjusting for covariates, there was no statistically significant difference in T2 between the four subgroups (P = 0.359). DATA CONCLUSIONS: Eccentric LVH is associated with the most pronounced evidence of myocardial tissue characteristics and function impairment, while as a benign remodeling, the concentric remodeling subgroup had the least increase in native T1. This study further confirms that native T1 and strain indicators can reflect the severity of myocardial injury in ESRD, providing better histological and functional basis for future grouping treatments. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY: Stage 3.

17.
Muscle Nerve ; 70(3): 346-351, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38924089

RESUMEN

INTRODUCTION/AIMS: T2 magnetic resonance imaging (MRI) mapping has been applied to carpal tunnel syndrome (CTS) for quantitative assessment of the median nerve. However, quantitative changes in the median nerve before and after surgery using T2 MRI mapping remain unclear. We aimed to investigate whether pathological changes could be identified by pre- and postoperative T2 MRI mapping of the median nerve in CTS patients after open carpal tunnel release. METHODS: This was a prospective study that measured median nerve T2 and cross-sectional area (CSA) values at the distal carpal tunnel, hamate bone, proximal carpal tunnel, and forearm levels pre- and postoperatively. Associations between T2, CSA, and nerve conduction latency were also evaluated. RESULTS: A total of 36 patients with CTS (mean age, 64.5 ± 11.7 years) who underwent surgery were studied. The mean preoperative T2 values significantly decreased from 56.3 to 46.9 ms at the proximal carpal tunnel levels (p = .001), and from 52.4 to 48.7 ms at the hamate levels postoperatively (p = .04). Although there was a moderate association between preoperative T2 values at the distal carpal tunnel levels and distal motor latency values (r = -.46), other T2 values at all four carpal tunnel levels were not significantly associated with CSA or nerve conduction latency pre- or postoperatively. DISCUSSION: T2 MRI mapping of the carpal tunnel suggested a decrease in nerve edema after surgery. T2 MRI mapping provides quantitative information on the median nerve before and after surgery.


Asunto(s)
Síndrome del Túnel Carpiano , Imagen por Resonancia Magnética , Nervio Mediano , Conducción Nerviosa , Humanos , Síndrome del Túnel Carpiano/cirugía , Síndrome del Túnel Carpiano/diagnóstico por imagen , Nervio Mediano/diagnóstico por imagen , Femenino , Masculino , Persona de Mediana Edad , Anciano , Conducción Nerviosa/fisiología , Estudios Prospectivos , Adulto
18.
J Cardiovasc Magn Reson ; 26(1): 101033, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38460840

RESUMEN

BACKGROUND: Left ventricular ejection fraction (LVEF) is the most commonly clinically used imaging parameter for assessing cancer therapy-related cardiac dysfunction (CTRCD). However, LVEF declines may occur late, after substantial injury. This study sought to investigate cardiovascular magnetic resonance (CMR) imaging markers of subclinical cardiac injury in a miniature swine model. METHODS: Female Yucatan miniature swine (n = 14) received doxorubicin (2 mg/kg) every 3 weeks for 4 cycles. CMR, including cine, tissue characterization via T1 and T2 mapping, and late gadolinium enhancement (LGE) were performed on the same day as doxorubicin administration and 3 weeks after the final chemotherapy cycle. In addition, magnetic resonance spectroscopy (MRS) was performed during the 3 weeks after the final chemotherapy in 7 pigs. A single CMR and MRS exam were also performed in 3 Yucatan miniature swine that were age- and weight-matched to the final imaging exam of the doxorubicin-treated swine to serve as controls. CTRCD was defined as histological early morphologic changes, including cytoplasmic vacuolization and myofibrillar loss of myocytes, based on post-mortem analysis of humanely euthanized pigs after the final CMR exam. RESULTS: Of 13 swine completing 5 serial CMR scans, 10 (77%) had histological evidence of CTRCD. Three animals had neither histological evidence nor changes in LVEF from baseline. No absolute LVEF <40% or LGE was observed. Native T1, extracellular volume (ECV), and T2 at 12 weeks were significantly higher in swine with CTRCD than those without CTRCD (1178 ms vs. 1134 ms, p = 0.002, 27.4% vs. 24.5%, p = 0.03, and 38.1 ms vs. 36.4 ms, p = 0.02, respectively). There were no significant changes in strain parameters. The temporal trajectories in native T1, ECV, and T2 in swine with CTRCD showed similar and statistically significant increases. At the same time, there were no differences in their temporal changes between those with and without CTRCD. MRS myocardial triglyceride content substantially differed among controls, swine with and without CTRCD (0.89%, 0.30%, 0.54%, respectively, analysis of variance, p = 0.01), and associated with the severity of histological findings and incidence of vacuolated cardiomyocytes. CONCLUSION: Serial CMR imaging alone has a limited ability to detect histologic CTRCD beyond LVEF. Integrating MRS myocardial triglyceride content may be useful for detection of early potential CTRCD.


Asunto(s)
Cardiotoxicidad , Modelos Animales de Enfermedad , Doxorrubicina , Imagen por Resonancia Cinemagnética , Miocardio , Valor Predictivo de las Pruebas , Volumen Sistólico , Porcinos Enanos , Función Ventricular Izquierda , Animales , Femenino , Miocardio/patología , Miocardio/metabolismo , Porcinos , Función Ventricular Izquierda/efectos de los fármacos , Volumen Sistólico/efectos de los fármacos , Factores de Tiempo , Espectroscopía de Resonancia Magnética , Antibióticos Antineoplásicos/efectos adversos , Medios de Contraste , Disfunción Ventricular Izquierda/inducido químicamente , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/fisiopatología , Disfunción Ventricular Izquierda/patología , Disfunción Ventricular Izquierda/metabolismo
19.
Br J Anaesth ; 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-39095237

RESUMEN

Myocardial injury after noncardiac surgery (MINS) and perioperative myocardial injury are associated with increased morbidity and mortality. Both are diagnosed by a perioperative increase in troponin, yet there is controversy if MINS is a genuine myocardial insult. We applied postoperative cardiovascular magnetic resonance T2 mapping techniques to visualise acute myocardial injury (i.e. oedema) in six patients with multiple cardiovascular risk factors who underwent aortic surgery. The burden of myocardial oedema was substantially higher in four patients with elevated troponin qualifying for MINS, compared with patients without MINS. The data and images suggest that MINS represents genuine myocardial injury.

20.
MAGMA ; 2024 Jul 23.
Artículo en Inglés | MEDLINE | ID: mdl-39042205

RESUMEN

OBJECTIVE: Quantitative parameter mapping conventionally relies on curve fitting techniques to estimate parameters from magnetic resonance image series. This study compares conventional curve fitting techniques to methods using neural networks (NN) for measuring T2 in the prostate. MATERIALS AND METHODS: Large physics-based synthetic datasets simulating T2 mapping acquisitions were generated for training NNs and for quantitative performance comparisons. Four combinations of different NN architectures and training corpora were implemented and compared with four different curve fitting strategies. All methods were compared quantitatively using synthetic data with known ground truth, and further compared on in vivo test data, with and without noise augmentation, to evaluate feasibility and noise robustness. RESULTS: In the evaluation on synthetic data, a convolutional neural network (CNN), trained in a supervised fashion using synthetic data generated from naturalistic images, showed the highest overall accuracy and precision amongst the methods. On in vivo data, this best performing method produced low-noise T2 maps and showed the least deterioration with increasing input noise levels. DISCUSSION: This study showed that a CNN, trained with synthetic data in a supervised manner, may provide superior T2 estimation performance compared to conventional curve fitting, especially in low signal-to-noise regions.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA