1.
Biosens Bioelectron ; 89(Pt 1): 400-410, 2017 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-27268013

RESUMO

Dopamine (DA) is a monoamine neurotransmitter responsible for regulating a variety of vital life functions. In vivo detection of DA poses a challenge due to the low concentration and high speed of physiological signaling. Fast scan cyclic voltammetry at carbon fiber microelectrodes (CFEs) is an effective method to monitor real-time in vivo DA signaling, however the sensitivity is somewhat limited. Electrodeposition of poly(3,4-ethylene dioxythiophene) (PEDOT)/graphene oxide (GO) onto the CFE surface is shown to increase the sensitivity and lower the limit of detection for DA compared to bare CFEs. Thicker PEDOT/GO coatings demonstrate higher sensitivities for DA, but display the negative drawback of slow adsorption and electron transfer kinetics. The moderate thickness resulting from 25 s electrodeposition of PEDOT/GO produces the optimal electrode, exhibiting an 880% increase in sensitivity, a 50% decrease in limit of detection and minimally altered electrode kinetics. PEDOT/GO coated electrodes rapidly and robustly detect DA, both in solution and in the rat dorsal striatum. This increase in DA sensitivity is likely due to increasing the electrode surface area with a PEDOT/GO coating and improved adsorption of DA's oxidation product (DA-o-quinone). Increasing DA sensitivity without compromising electrode kinetics is expected to significantly improve our understanding of the DA function in vivo.


Assuntos
Compostos Bicíclicos Heterocíclicos com Pontes/química , Corpo Estriado/química , Dopamina/análise , Técnicas Eletroquímicas/métodos , Grafite/química , Polímeros/química , Animais , Técnicas Biossensoriais/métodos , Galvanoplastia , Limite de Detecção , Masculino , Microeletrodos , Ratos , Ratos Sprague-Dawley
2.
J Mater Chem B ; 5(42): 8417, 2017 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-32264509

RESUMO

Correction for 'Aptamer-functionalized neural recording electrodes for the direct measurement of cocaine in vivo' by I. Mitch Taylor et al., J. Mater. Chem. B, 2017, 5, 2445-2458.

3.
J Mater Chem B ; 5(13): 2445-2458, 2017 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-28729901

RESUMO

Cocaine is a highly addictive psychostimulant that acts through competitive inhibition of the dopamine transporter. In order to fully understand the region specific neuropathology of cocaine abuse and addiction, it is unequivocally necessary to develop cocaine sensing technology capable of directly measuring real-time cocaine transient events local to different brain regions throughout the pharmacokinetic time course of exposure. We have developed an electrochemical aptamer-based in vivo cocaine sensor on a silicon based neural recording probe platform capable of directly measuring cocaine from discrete brain locations using square wave voltammetry (SWV). The sensitivity of the sensor for cocaine follows a modified exponential Langmuir model relationship and complete aptamer-target binding occurs in < 2 sec and unbinding in < 4 sec. The resulting temporal resolution is a 75X increase from traditional microdialysis sampling methods. When implanted in the rat dorsal striatum, the cocaine sensor exhibits stable SWV signal drift (modeled using a logarithmic exponential equation) and is capable of measuring real-time in vivo response to repeated local cocaine infusion as well as systemic IV cocaine injection. The in vivo sensor is capable of obtaining reproducible measurements over a period approaching 3 hours, after which signal amplitude significantly decreases likely due to tissue encapsulation. Finally, aptamer functionalized neural recording probes successfully detect spontaneous and evoked neural activity in the brain. This dual functionality makes the cocaine sensor a powerful tool capable of monitoring both biochemical and electrophysiological signals with high spatial and temporal resolution.

4.
Biosensors (Basel) ; 5(4): 618-46, 2015 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-26473938

RESUMO

Neural electrodes hold tremendous potential for improving understanding of brain function and restoring lost neurological functions. Multi-walled carbon nanotube (MWCNT) and dexamethasone (Dex)-doped poly(3,4-ethylenedioxythiophene) (PEDOT) coatings have shown promise to improve chronic neural electrode performance. Here, we employ electrochemical techniques to characterize the coating in vivo. Coated and uncoated electrode arrays were implanted into rat visual cortex and subjected to daily cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) for 11 days. Coated electrodes experienced a significant decrease in 1 kHz impedance within the first two days of implantation followed by an increase between days 4 and 7. Equivalent circuit analysis showed that the impedance increase is the result of surface capacitance reduction, likely due to protein and cellular processes encapsulating the porous coating. Coating's charge storage capacity remained consistently higher than uncoated electrodes, demonstrating its in vivo electrochemical stability. To decouple the PEDOT/MWCNT material property changes from the tissue response, in vitro characterization was conducted by soaking the coated electrodes in PBS for 11 days. Some coated electrodes exhibited steady impedance while others exhibiting large increases associated with large decreases in charge storage capacity suggesting delamination in PBS. This was not observed in vivo, as scanning electron microscopy of explants verified the integrity of the coating with no sign of delamination or cracking. Despite the impedance increase, coated electrodes successfully recorded neural activity throughout the implantation period.


Assuntos
Anti-Inflamatórios/química , Compostos Bicíclicos Heterocíclicos com Pontes/química , Materiais Revestidos Biocompatíveis/química , Dexametasona/química , Nanotubos de Carbono/química , Próteses Neurais , Polímeros/química , Córtex Visual/fisiologia , Animais , Impedância Elétrica , Técnicas Eletroquímicas , Masculino , Microeletrodos , Ratos , Ratos Long-Evans , Córtex Visual/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA