Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 166
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Cardiovasc Electrophysiol ; 35(2): 348-359, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38180129

RESUMO

INTRODUCTION: It would be helpful in determining ablation strategy if the occurrence of perimitral atrial tachycardia (PMAT) could be predicted in advance. We investigated whether estimated perimitral conduction time (E-PMCT), namely, twice the time between coronary sinus (CS) pacing and the ensuing wave-front collision at the opposite side of the mitral annulus, correlated with the cycle length of PMAT and could predict future PMAT. METHODS AND RESULTS: We retrospectively (retrospective cohort) and prospectively (validation cohort) investigated atrial fibrillation patients who had received pulmonary vein isolation (PVI) and in whom left atrial maps had been created during CS pacing. We calculated their E-PMCT. PMAT was observed either by provocation or during follow-up in 25, AT other than PMAT was observed in 24 (non-PMAT AT group), and 53 patients never displayed any AT (no-AT group) in the retrospective cohort. In the PMAT group of the retrospective cohort, a strong positive correlation was observed between the PMAT CL and E-PMCT (r = .85, p < 0.001). PMAT was never induced nor observed in patients with E-PMCT less than 176 ms, and the best cut-off value for PMAT was 180 ms by receiver-operating characteristic curve analysis. In the validation cohort of 76 patients, the cut-off value of the E-PMAT less than 180 ms predicted noninducibility of PMAT, with a sensitivity of 78.6%, specificity of 100%, positive predictive value of 100%, and negative predictive value of 25.0%. CONCLUSION: Short E-PMCT may predict noninducibility of PMAT and guide a less invasive ablation strategy.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Taquicardia Supraventricular , Humanos , Estudos Retrospectivos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/etiologia , Taquicardia Supraventricular/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Frequência Cardíaca , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Resultado do Tratamento , Veias Pulmonares/cirurgia
2.
Ann Noninvasive Electrocardiol ; 29(1): e13100, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38115789

RESUMO

BACKGROUND: Posteroseptal accessory pathways (APs) associated with coronary sinus (CS) diverticulum present a rare and challenge for ablation. This study aimed to compare the safety and efficacy of conventional approach and three-dimensional (3D) mapping system in the catheter ablation. METHODS AND RESULTS: This was a retrospective study of all patients (from January 2013 to July 2022) who underwent catheter ablation of posteroseptal AP associated with CS diverticula in our center. Patients who underwent catheter ablation using the traditional fluoroscopy method were included in the conventional method group (n = 13). Patients who underwent catheter ablation using the 3D mapping method were included in the 3D mapping group (n = 11). Clinical characteristics, ablation procedure, and outcomes were recorded and analyzed between the two groups. Out of 669 patients with posteroseptal APs, 24 of them (3.6%) were associated with CS diverticula. All patients in both groups successfully completed the electrophysiological study. In the conventional method group, two patients experienced complications (one patient with pericardial effusion and the other patient with femoral arterial hematoma), and two patients had recurrence. However, no patients suffered from complications or recurrence during follow-up. The procedure time and fluoroscopy time in the conventional method group were significantly longer than those in the 3D mapping method group. CONCLUSIONS: The utilization of 3D mapping led to reduced fluoroscopy time, shorter procedure duration, enhanced acute success rates, and decreased incidence of complications.


Assuntos
Feixe Acessório Atrioventricular , Ablação por Cateter , Seio Coronário , Divertículo , Cardiopatias Congênitas , Humanos , Seio Coronário/diagnóstico por imagem , Seio Coronário/cirurgia , Estudos Retrospectivos , Eletrocardiografia/métodos , Feixe Acessório Atrioventricular/diagnóstico por imagem , Feixe Acessório Atrioventricular/cirurgia , Cardiopatias Congênitas/cirurgia , Ablação por Cateter/métodos , Divertículo/complicações , Divertículo/diagnóstico por imagem , Divertículo/cirurgia
3.
Pediatr Cardiol ; 45(2): 368-376, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38071252

RESUMO

In verapamil-sensitive left posterior fascicular ventricular tachycardia (LPF-VT), radiofrequency catheter ablation (RFA) is performed targeting mid-to-late diastolic potential (P1) and presystolic potential (P2) during tachycardia. This study included four patients who had undergone electrophysiological study (EPS) and pediatric patients with verapamil-sensitive LPF-VT who had undergone RFA using high-density three-dimensional (3D) mapping. The included patients were 11-14 years old. During EPS, right bundle branch block and superior configuration VT were induced in all patients. VT mapping was performed via the transseptal approach. P1 and P2 during VT were recorded in three of the four patients. All patients initially underwent RFA via the transseptal approach. In three patients, P1 during VT was targeted, and VT was terminated. The lesion size indices in which VT was terminated were 4.6, 4.6, and 4.7. For one patient whose P1 could not be recorded, linear ablation was performed perpendicularly in the area where P2 was recorded during VT. Among the three patients in whom VT was terminated, linear ablation was performed in two to eliminate the ventricular echo beats. In all patients, VT became uninducible in the acute phase and had not recurred 8-24 months after RFA. High-density 3D mapping with an HD Grid Mapping Catheter allows recording of P1 and P2 during VT and may improve the success rate of RFA in pediatric patients with verapamil-sensitive LPF-VT.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Criança , Adolescente , Taquicardia Ventricular/cirurgia , Eletrocardiografia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Bloqueio de Ramo , Ablação por Cateter/métodos , Verapamil/uso terapêutico , Resultado do Tratamento
4.
Sensors (Basel) ; 24(8)2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38676111

RESUMO

This paper introduces an innovative approach to 3D environmental mapping through the integration of a compact, handheld sensor package with a two-stage sensor fusion pipeline. The sensor package, incorporating LiDAR, IMU, RGB, and thermal cameras, enables comprehensive and robust 3D mapping of various environments. By leveraging Simultaneous Localization and Mapping (SLAM) and thermal imaging, our solution offers good performance in conditions where global positioning is unavailable and in visually degraded environments. The sensor package runs a real-time LiDAR-Inertial SLAM algorithm, generating a dense point cloud map that accurately reconstructs the geometric features of the environment. Following the acquisition of that point cloud, we post-process these data by fusing them with images from the RGB and thermal cameras and produce a detailed, color-enriched 3D map that is useful and adaptable to different mission requirements. We demonstrated our system in a variety of scenarios, from indoor to outdoor conditions, and the results showcased the effectiveness and applicability of our sensor package and fusion pipeline. This system can be applied in a wide range of applications, ranging from autonomous navigation to smart agriculture, and has the potential to make a substantial benefit across diverse fields.

5.
J Synchrotron Radiat ; 30(Pt 2): 445-448, 2023 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-36891858

RESUMO

In Bragg coherent diffractive imaging, the precise location of the measured crystals in the interior of the sample is usually missing. Obtaining this information would help the study of the spatially dependent behavior of particles in the bulk of inhomogeneous samples, such as extra-thick battery cathodes. This work presents an approach to determine the 3D position of particles by precisely aligning them at the instrument axis of rotation. In the test experiment reported here, with a 60 µm-thick LiNi0.5Mn1.5O4 battery cathode, the particles were located with a precision of 20 µm in the out-of-plane direction, and the in-plane coordinates were determined with a precision of 1 µm.

6.
J Cardiovasc Electrophysiol ; 34(8): 1658-1664, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37393583

RESUMO

BACKGROUND: Although atrial flutter (AFL) is a common arrhythmia that is based on a macro-reentrant tachycardia around the tricuspid annulus, the factors giving rise to typical AFL (t-AFL) versus reverse typical AFL (rt-AFL) are unknown. To investigate the difference between t-AFL and rt-AFL circuits using ultrahigh resolution mapping of the right atrium. METHODS: We investigated 30 isthmus-dependent AFL patients (mean age 71, 28 male) who underwent first-time cavo-tricuspid isthmus (CTI) ablation guided by Boston Scientific's Rhythmia mapping system and divided them into two groups: t-AFL (22 patients) and rt-AFL (8 patients). We compared the anatomy and electrophysiology of their reentrant circuits. RESULTS: Baseline patient characteristics, use of antiarrhythmic drugs, prevalence of atrial fibrillation, AFL cycle length (227.1 ± 21.4 vs. 245.5 ± 36.0 ms, p = .10), and CTI length (31.9 ± 8.3 vs. 31.1 ± 5.2 mm, p = .80) did not differ between the two groups. Functional block was observed at the crista terminalis in 16 patients and at the sinus venosus in 11. No functional block was observed in three patients, all of whom belonged to the rt-AFL group. That is, functional block was observed in 100% of the t-AFL group as opposed to 5/8 (62.5%) of the rt-AFL (p < .05). Slow conduction zones were frequently observed at the intra-atrial septum in the t-AFL group and at the CTI in the rt-AFL group. CONCLUSION: Mapping with ultrahigh-resolution mapping showed differences between t-AFL and rt-AFL in conduction properties in the right atrium and around the tricuspid valve, which suggested directional mechanisms.


Assuntos
Flutter Atrial , Ablação por Cateter , Humanos , Masculino , Flutter Atrial/diagnóstico , Flutter Atrial/cirurgia , Átrios do Coração , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Frequência Cardíaca/fisiologia
7.
J Cardiovasc Electrophysiol ; 34(1): 35-43, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36217991

RESUMO

INTRODUCTION: Variability of the bipolar atrial electrogram amplitude may affect voltage maps created during ablation procedures, and thus also the extent of ablations. Therefore, the aim of the study was to assess the beat-to-beat electrogram amplitude variability in the left atrium in patients undergoing atrial fibrillation ablation. METHODS: In 11 patients undergoing ablation for atrial fibrillation, 362 mapping points were collected in two series. At each point, three consecutive beats were recorded and verified including the bipolar electrogram amplitude, contact force (CF), and orientation of the catheter tip. The repeatability and reproducibility of obtained measurements between consecutive beats and series were assessed by the Pearson correlation coefficient (r), the Bland-Altman test, repeatability coefficient (RC), relative standard deviation (RSD), and concordance correlation coefficient (CCC). RESULTS: A total of 1086 beats were analyzed. The correlation coefficient for bipolar atrial electrogram amplitude for the first two beats, and for the first and the third beats were 0.94 and 0.86, respectively. The average of differences between the first two beats and between the first and the third beats were 0.06 and 0.13 mV with 95% limits of agreement (LoA) within ±0.98 and ±1.74 mV, respectively. For CF values ≤5 and ≥20 g, the 95% LoA were narrower compared to other CF ranges and were ±0.49 and ±0.71 mV from the average value, respectively. When the analyzes were performed within the predefined ranges of bipolar electrogram amplitude: 0.05-1; 1-2; 2-3 mV, the 95% LoA were within ±0.33, ±0.98, and ±0.84 mV from the average value, respectively. RC and RSD were 1.41 mV and 20.8%, respectively. For repeated measurement between series, CCC ranged from 0.67 to 0.71 and the 95% LoA were within ±2.7 to 2.9 mV from the average value. CONCLUSION: Bipolar atrial electrogram amplitude recorded at a given site during ablation procedures is variable to an extent that may be clinically relevant. The magnitude of the observed variability is greater during remapping.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Técnicas Eletrofisiológicas Cardíacas/métodos , Reprodutibilidade dos Testes , Átrios do Coração , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
8.
J Cardiovasc Electrophysiol ; 34(9): 2002-2005, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37526239

RESUMO

BACKGROUND: A 70-year-old man revealed a rare type of atrioventricular nodal re-entrant tachycardia (AVNRT) involving distinct retrograde pathways, superior slow pathway, and inferolateral left atrial slow pathway. RESULT: Radiofrequency ablation was successfully performed on the noncoronary cusp and in the left atrium, respectively, to eliminate the tachycardias. DISCUSSION AND CONCLUSION: Due to the anomalous electrical conduction patterns, careful diagnosis and ablation strategies were necessary to avoid the risk of atrioventricular block. These findings underscore the diversity and complexity of AVNRT and highlight the importance of tailored therapeutic approaches.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Taquicardia por Reentrada no Nó Atrioventricular , Masculino , Humanos , Idoso , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Fibrilação Atrial/cirurgia , Eletrocardiografia , Fascículo Atrioventricular , Átrios do Coração
9.
J Muscle Res Cell Motil ; 44(4): 255-270, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37258982

RESUMO

The thick filament-associated A-band region of titin is a highly repetitive component of the titin chain with important scaffolding properties that support thick filament assembly. It also has a demonstrated link to human disease. Despite its functional significance, it remains a largely uncharacterized part of the titin protein. Here, we have performed an analysis of sequence and structure conservation of A-band titin, with emphasis on poly-FnIII tandem components. Specifically, we have applied multi-dimensional sequence pairwise similarity analysis to FnIII domains and complemented this with the crystallographic elucidation of the 3D-structure of the FnIII-triplet A84-A86 from the fourth long super-repeat in the C-zone (C4). Structural models serve here as templates to map sequence conservation onto super-repeat C4, which we show is a prototypical representative of titin's C-zone. This templating identifies positionally conserved residue clusters in C super-repeats with the potential of mediating interactions to thick-filament components. Conservation localizes to two super-repeat positions: Ig domains in position 1 and FnIII domains in position 7. The analysis also allows conclusions to be drawn on the conserved architecture of titin's A-band, as well as revisiting and expanding the evolutionary model of titin's A-band.


Assuntos
Proteínas Musculares , Sarcômeros , Humanos , Conectina/metabolismo , Proteínas Musculares/metabolismo , Sarcômeros/metabolismo
10.
Europace ; 25(3): 1126-1134, 2023 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-36610064

RESUMO

AIMS: Transseptal puncture (TP) for left-sided catheter ablation procedures is routinely performed under fluoroscopic or echocardiographic guidance [transoesophageal echocardiography (TEE) or intracardiac echocardiography (ICE)], although three-dimensional (3D) mapping systems are readily available in most electrophysiology laboratories. Here, we sought to assess the feasibility and safety of a right atrial (RA) 3D map-guided TP. METHODS AND RESULTS: In 104 patients, 3D RA mapping was performed to identify the fossa ovalis (FO) using the protrusion technique. The radiofrequency transseptal needle was visualized and navigated to the desired potential FO-TP site. Thereafter, the interventionalist was unblinded to TEE and the potential FO-TP site was reassessed regarding its convenience and safety. After TP, the exact TP site was documented using a 17-segment-FO model. Reliable identification of the FO was feasible in 102 patients (98%). In these, 114 3D map-guided TP attempts were performed, of which 96 (84%) patients demonstrated a good position and 18 (16%) an adequate position after TEE unblinding. An out-of-FO or dangerous position did not occur. A successful 3D map-guided TP was performed in 110 attempts (97%). Four attempts (3%) with adequate positions were aborted in order to seek a more convenient TP site. The median time from RA mapping until the end of the TP process was 13 (12-17) min. No TP-related complications occurred. Ninety-eight TP sites (85.1%) were in the central portion or in the inner loop of the FO. CONCLUSION: A 3D map-guided TP is feasible and safe. It may assist to decrease radiation exposure and the need for TEE/ICE during left-sided catheter ablation procedures.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Estudos de Viabilidade , Cateterismo Cardíaco/métodos , Átrios do Coração , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Punções , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Resultado do Tratamento
11.
Pacing Clin Electrophysiol ; 46(6): 543-547, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36815543

RESUMO

The recently published "electrophysiologically guided low-voltage bridge (LVB) strategy" is effective in the ablation of atrioventricular nodal re-entry tachycardia (AVNRT) in children. This study aimed to evaluate its efficacy and safety in children <26 kgs. Fourteen children [64% males, median age 6.5 years (IQR 6-8 years), median weight 25.5 kg (IQR 24-26 kg)] with AVNRT were treated. In all patients, we detected a LVB associated to a typical slow pathway potential. The acute success rate was 100% with a mean of 5.5 cryoablation deliveries. All procedures were performed with near-zero fluoroscopic exposure (median time 0.15 min, IQR 0-0.7 min), in six patients fluoroscopy was 0 min. There were no complications or recurrences during the follow-up (median 20.91 months, IQR 11.7-26.7 months).


Assuntos
Ablação por Cateter , Criocirurgia , Taquicardia por Reentrada no Nó Atrioventricular , Masculino , Humanos , Criança , Feminino , Criocirurgia/métodos , Resultado do Tratamento , Potenciais de Ação , Fatores de Tempo , Recidiva
12.
Pacing Clin Electrophysiol ; 46(8): 875-881, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37483154

RESUMO

AIM: The implementation of 3D mapping systems plays an important role in interventional electrophysiology (EP) in recent years. The aim of the present study was to evaluate use of 3D mapping systems regarding fluoroscopy and procedure duration. METHOD: In the "Go for Zero Fluoroscopy" project 25 European centers provided data of consecutive EP procedures. Data on use of 3D mapping systems as well as utilization of contact force catheters and multipolar mapping catheters were associated with fluoroscopy time, dose area product (DAP), and procedure duration. RESULT: A 3D mapping system was used in 966 (54%) cases. Use of 3D mapping for atrioventricular nodal reentry tachycardia (AVNRT) was associated with reduced fluoroscopy time (p < 0.001), DAP (p = 0.04) but increased procedure time (p = 0.029). Moreover, fluoroscopy time (p < 0.001) and DAP (p = 0.005) were significantly lower in the 3D mapping group in ablation of typical atrial flutter. However, the procedure time (p < 0.001) increased. Use of 3D mapping in the ablation of accessory pathway (AP) was associated with reduced fluoroscopy time (p < 0.001) and DAP (p < 0.001) with no significant increase in procedure time (p = 0.066). In the case of atrial fibrillation, a 3D mapping system was used in 485 patients (75.8%). Additional use of a contact force catheter was associated with lower fluoroscopy time (p < 0.001) and DAP (p < 0.001). Use of a multipolar mapping catheter was associated with lower fluoroscopy time (p = 0.002). The implementation of 3D mapping systems in the ablation of ventricular tachycardias resulted in a significant increase in the procedure time (p = 0.001) without significant differences regarding the DAP (p = 0.773) and fluoroscopy time (p = 0.249). CONCLUSION: Use of 3D mapping systems in ablation of supraventricular tachycardias is associated with lower radiation exposure. Nevertheless, the procedure time often increases, except in the case of ablation for AP. Use of contact force catheters and multipolar mapping catheters is associated with yet lower radiation exposure values. Prospective randomized studies are needed to further elucidate potential benefit of these technological tools.


Assuntos
Feixe Acessório Atrioventricular , Fibrilação Atrial , Ablação por Cateter , Humanos , Estudos Prospectivos , Resultado do Tratamento , Fibrilação Atrial/cirurgia , Feixe Acessório Atrioventricular/cirurgia , Eletrofisiologia Cardíaca , Fluoroscopia/métodos , Ablação por Cateter/métodos
13.
Cardiol Young ; 33(5): 754-759, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-35673794

RESUMO

BACKGROUND: Electroanatomic mapping systems are increasingly used during ablations to decrease the need for fluoroscopy and therefore radiation exposure. For left-sided arrhythmias, transseptal puncture is a common procedure performed to gain access to the left side of the heart. We aimed to demonstrate the radiation exposure associated with transseptal puncture. METHODS: Data were retrospectively collected from the Catheter Ablation with Reduction or Elimination of Fluoroscopy registry. Patients with left-sided accessory pathway-mediated tachycardia, with a structurally normal heart, who had a transseptal puncture, and were under 22 years of age were included. Those with previous ablations, concurrent diagnostic or interventional catheterisation, and missing data for fluoroscopy use or procedural outcomes were excluded. Patients with a patent foramen ovale who did not have a transseptal puncture were selected as the control group using the same criteria. Procedural outcomes were compared between the two groups. RESULTS: There were 284 patients in the transseptal puncture group and 70 in the patent foramen ovale group. The transseptal puncture group had a significantly higher mean procedure time (158.8 versus 131.4 minutes, p = 0.002), rate of fluoroscopy use (38% versus 7%, p < 0.001), and mean fluoroscopy time (2.4 versus 0.6 minutes, p < 0.001). The acute success and complication rates were similar. CONCLUSIONS: Performing transseptal puncture remains a common reason to utilise fluoroscopy in the era of non-fluoroscopic ablation. Better tools are needed to make non-fluoroscopic transseptal puncture more feasible.


Assuntos
Ablação por Cateter , Forame Oval Patente , Exposição à Radiação , Humanos , Estudos Retrospectivos , Resultado do Tratamento , Punções/métodos , Ablação por Cateter/métodos
14.
Sensors (Basel) ; 23(3)2023 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-36772591

RESUMO

This paper describes an affordable robotic mobile 3D mapping system. It is built with Livox Mid-40 lidar with a conic field of view extended by a custom rotating planar reflector. This 3D sensor is compared with the more expensive Velodyne VLP 16 lidar. It is shown that the proposed sensor reaches satisfactory accuracy and range. Furthermore, it is able to preserve the metric accuracy and non-repetitive scanning pattern of the unmodified sensor. Due to preserving the non-repetitive scan pattern, our system is capable of covering the entire field of view of 38.4 × 360 degrees, which is an added value of conducted research. We show the calibration method, mechanical design, and synchronization details that are necessary to replicate our system. This work extends the applicability of solid-state lidars since the field of view can be reshaped with minimal loss of measurement properties. The solution was part of a system that was evaluated during the 3rd European Robotics Hackathon in the Zwentendorf Nuclear Power Plant. The experimental part of the paper demonstrates that our affordable robotic mobile 3D mapping system is capable of providing 3D maps of a nuclear facility that are comparable to the more expensive solution.

15.
Sensors (Basel) ; 23(14)2023 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-37514826

RESUMO

The architectural heritage of the 20th century is affected by several conservation problems in terms of material preservation, structural analysis, and reuse. Among these, material degradation and durability issues are the ones that have the most effect on the health state and, consequently, the survival of the constructions of the period. In order to conduct a proper analysis for preservation purposes, an interdisciplinary approach is necessary. The parabolic arch in Morano sul Po (Italy) is a reinforced concrete landmark in the Casale Monferrato area and is related to the industrial vocation of the territory, which is indissolubly linked to the cement production chain. The present paper reports the results of a non-destructive test campaign by a Politecnico di Torino multidisciplinary group, which combined acquisitions using different methods. The paper highlights the importance of a structured procedure to integrate different information coming from different techniques. The aim was to assess the health state of the structure and define the best procedures for building an information system based on the as-built modeling strategy, which could serve as the basis to provide conservation guidelines.

16.
Eur J Orthop Surg Traumatol ; 33(5): 1713-1719, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35918618

RESUMO

PURPOSE: To characterize the fracture patterns of acetabular fractures and create fracture maps and comminution zones based on three-dimensional (3D) computed tomography (CT) images. METHODS: Sixty-eight computed tomography images of 67 patients (47 male [70.1%] and 20 female [29.9%], mean age: 45.2 ± 17.2 [range, 18-85 years] with the diagnosis of intra-articular acetabulum fracture were analyzed. Individual fracture lines were drawn and superimposed to a healthy acetabular template according to Judet-Letournel and simplified fracture classification systems. Fracture line, comminution zone, and heat maps were created using the computed tomography mapping technique. RESULTS: Fracture lines were distributed mainly in a horizontal and oblique orientation, which concentrated in the anteroinferior part of the joint in anterior fractures. Posterior fractures mostly had an oblique orientation, which lied between the acetabular dome and middle part of the posterior wall. In complex fractures, fracture lines were concentrated just above the cotyloid fossa, acetabular dome, and posterosuperior part of the acetabulum. The most common comminuted zones were around the central area of the articular surface and the anterior wall in anterior fractures, between the cotyloid fossa and dome in complex fractures, and the upper half posterior wall. CONCLUSION: Fracture patterns and comminution zones of acetabular fractures displayed certain characteristics. Some areas had higher comminution zones, and some areas remained intact in repeatable fracture patterns. These results may help surgeons in fixing acetabular fractures, designing new implants, and placement of acetabular component while performing THA after acetabular fractures.


Assuntos
Fraturas Ósseas , Fraturas Cominutivas , Fraturas do Quadril , Fraturas Intra-Articulares , Fraturas da Coluna Vertebral , Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Fraturas Ósseas/diagnóstico por imagem , Fraturas Cominutivas/diagnóstico por imagem , Fraturas Cominutivas/cirurgia , Tomografia Computadorizada por Raios X/métodos , Fixação Interna de Fraturas/métodos , Fraturas Intra-Articulares/diagnóstico por imagem , Fraturas Intra-Articulares/cirurgia , Acetábulo/cirurgia
17.
Eur J Orthop Surg Traumatol ; 33(7): 3001-3010, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36934361

RESUMO

PURPOSE: One of the major limitations of the 2D fracture evaluation (Schatzker classification) is its failure to adequately assess fracture lines in the frontal plane and fracture displacement in the antero-posterior direction. 3D fracture line mapping includes steric assessment which can aid decision making with regards to the surgical approach and fixation scheme. We hypothesized that there are consistent fracture patterns and zones of comminution for proximal tibial fractures. METHODS: Radiographic data of 228 proximal tibia fractures were retrospectively included in this study. Fracture lines and zones of comminution were graphically superimposed onto a 3D template of an intact tibia after virtual reduction and normalization to identify major patterns of fracture and comminution. RESULTS: Out of 206 male and 21 female patients, 89 had a fracture of the lateral condyle only (Schatzker I and II), 53 involved the medial plateau only (Schatzker IV) and 86 had a high-grade fracture involving both the condyles (Schatzker V and VI). 64.5% of the fracture lines involving the medial plateau alone were in the coronal plane, and this number was even lesser (44.2%) in medial plateau involvement of bicondylar fractures. In bicondylar fractures, lines were usually not seen to pass directly through the posteromedial region. CONCLUSIONS: Medial tibial plateau fractures have a mix of coronal or sagittal fracture alignment. A clearer understanding of the 3D orientations of fractures based on CT scans can aid in diagnosing the pattern of fracture and adequate positioning of plates can be done to eventually improve operative outcomes.


Assuntos
Fraturas Cominutivas , Fraturas da Tíbia , Humanos , Masculino , Feminino , Tíbia/diagnóstico por imagem , Tíbia/cirurgia , Estudos Retrospectivos , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/cirurgia , Imageamento Tridimensional , Fixação Interna de Fraturas
18.
J Cardiovasc Electrophysiol ; 33(6): 1183-1189, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35419906

RESUMO

INTRODUCTION: Ablation for atrioventricular nodal reentrant tachycardia (AVNRT) classically utilizes evaluation of signal morphology within the anatomic region of the slow pathway (SP), which involves subjectivity. Ripple mapping (RM; CARTO-3© Biosense Webster Inc) displays each electrogram at its three-dimensional coordinate as a bar changing in length according to its voltage-time relationship. This allows prolonged, low-amplitude signals to be displayed in their entirety, helping identify propagation in low-voltage areas. We set out to evaluate the ability of RM to locate the anatomic site of the SP and assess its use in guiding ablation for AVNRT. METHODS: Patients ≤18 years with AVNRT in the EP laboratory between 2017 and 2021 were evaluated. RM was performed to define region of SP conduction in patients from 2019 to 2021, whereas standard electro-anatomical mapping was used from 2017 to 2019. All ablations were performed using cryotherapy. Demographics, outcomes, and analysis of variance in number of test lesions until success was compared between groups. RESULTS: A total of 115 patients underwent AVRNT ablation during the study; 46 patients were in the RM group and 69 were in the control group. There were no demographic differences between groups. All procedures, in both groups, were acutely successful. In RM group, 89% of first successful lesions were within 4 mm of the predicted site. There was significantly reduced variability in number of test lesions until success in the RM group (p = .01). CONCLUSION: RM is a novel technique that can help identify SP location, allowing for successful ablation of AVNRT with decreased variability.


Assuntos
Ablação por Cateter , Taquicardia por Reentrada no Nó Atrioventricular , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Frequência Cardíaca , Humanos , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Fatores de Tempo , Resultado do Tratamento
19.
Rev Cardiovasc Med ; 23(3): 103, 2022 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-35345270

RESUMO

Outflow tract (OT) premature ventricular complexes (PVCs) are being recognized as a common and often troubling, clinical electrocardiographic finding. The OT areas consist of the Right Ventricular Outflow Tract (RVOT), the Left Ventricular Outflow Tract (LVOT), the Aortomitral Continuity (AMC), the aortic cusps and the Left Ventricular (LV) summit. By definition, all OT PVCs will exhibit an inferior QRS axis, defined as positive net forces in leads II, III and aVF. Activation mapping using the contemporary 3D mapping systems followed by pace mapping is the cornerstone strategy of every ablation procedure in these patients. In this mini review we discuss in brief all the modern mapping and ablation modalities for successful elimination of OT PVCs, along with the potential advantages and disadvantages of each ablation technique.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Complexos Ventriculares Prematuros , Ablação por Cateter/efeitos adversos , Eletrocardiografia/métodos , Ventrículos do Coração , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/cirurgia
20.
Pacing Clin Electrophysiol ; 45(3): 431-434, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34752651

RESUMO

An 84-year-old woman with type B Wolff-Parkinson-White (WPW) with Ebstein anomaly was admitted with heart failure. She had rapid wide QRS tachycardia due to accessory pathway (AP) conduction associated with atrial fibrillation (AF). Since transesophageal echocardiography before catheter ablation showed a left atrial thrombus, ablation was performed using a 3D mapping system under AF. After marking the functional tricuspid anulus with intra-cardiac echocardiography, 3D intra-cardiac electrogram visualization (ripple map) during AF enabled clear identification of location of the AP. After ablation, there was no complication of cerebral infarction, and the heart failure improved.


Assuntos
Feixe Acessório Atrioventricular , Fibrilação Atrial , Ablação por Cateter , Anomalia de Ebstein , Insuficiência Cardíaca , Síndrome de Wolff-Parkinson-White , Feixe Acessório Atrioventricular/complicações , Feixe Acessório Atrioventricular/cirurgia , Idoso de 80 Anos ou mais , Ablação por Cateter/efeitos adversos , Anomalia de Ebstein/complicações , Anomalia de Ebstein/cirurgia , Eletrocardiografia , Feminino , Insuficiência Cardíaca/complicações , Humanos , Síndrome de Wolff-Parkinson-White/complicações , Síndrome de Wolff-Parkinson-White/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA