Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 419
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Anal Bioanal Chem ; 416(14): 3335-3347, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38661944

RESUMO

Stanozolol, a synthetic derivative of testosterone, is one of the common doping drugs among athletes and bodybuilders. It is metabolized to a large extent and metabolites are detected in urine for a longer duration than the parent compound. In this study, a novel dummy molecularly imprinted polymer (DMIP) is developed as a sorbent for solid-phase extraction of stanozolol metabolites from spiked human urine samples. The optimized DMIP is composed of stanozolol as the dummy template, methacrylic acid as the functional monomer, and ethylene glycol dimethacrylate as the cross-linker in a ratio of 1:10:80. The extracted analytes were quantitively determined using a newly developed and validated ultrahigh-performance liquid chromatography tandem mass spectrometry method, where the limits of detection and quantitation were 0.91 and 1.81 ng mL-1, respectively, fulfilling the minimum required performance limit decided on by the World Anti-Doping Agency. The mean percentage extraction recoveries for 3'-hydroxystanozolol, 4ß-hydroxystanozolol, and 16ß-hydroxystanozolol are 97.80% ± 13.80, 83.16% ± 7.50, and 69.98% ± 2.02, respectively. As such, the developed DMISPE can serve as an efficient cost-effective tool for doping and regulatory agencies for simultaneous clean-up of the stanozolol metabolites prior to their quantification.


Assuntos
Dopagem Esportivo , Limite de Detecção , Polímeros Molecularmente Impressos , Extração em Fase Sólida , Estanozolol , Estanozolol/urina , Extração em Fase Sólida/métodos , Humanos , Polímeros Molecularmente Impressos/química , Dopagem Esportivo/prevenção & controle , Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Massas em Tandem/métodos , Detecção do Abuso de Substâncias/métodos , Anabolizantes/urina , Anabolizantes/metabolismo , Impressão Molecular/métodos
2.
Anal Bioanal Chem ; 416(13): 3223-3237, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38573345

RESUMO

Over the past few decades, anabolic androgenic steroids (AASs) have been abused in and out of competition for their performance-enhancing and muscle-building properties. Traditionally, AASs were commonly detected using gas chromatography-mass spectrometry in the initial testing procedure for doping control purposes. Gas chromatography-Orbitrap high-resolution mass spectrometry (GC-Orbitrap-HRMS) is a new technology that has many advantages in comparison with GC-MS (e.g., a maximum resolving power of 240,000 (FWHM at m/z 200), excellent sub-ppm mass accuracy, and retrospective data analysis after data acquisition). Anti-doping practitioners are encouraged to take full advantage of the updated techniques of chromatography-mass spectrometry to develop sensitive, specific, and rapid screening methods for AASs. A new method for screening a wide range of AASs in human urine using GC-Orbitrap-HRMS was developed and validated. The method can qualitatively determine 70 anabolic androgenic steroids according to the minimum required performance limit of the World Anti-Doping Agency. Moreover, the validated method was successfully applied to detect six metabolites in urine after the oral administration of metandienone, and their excretion curves in vivo were studied. Metandienone M6 (17ß-hydroxymethyl-17α-methyl-18-nor-androst-1,4,13-trien-3-one) has been identified as a long-term urinary metabolite which can be detected up to 7 weeks, thus providing a longer detection window compared with previous studies. This study provides a rationale for GC-Orbitrap-HRMS in drug metabolism and non-targeted screening.


Assuntos
Anabolizantes , Dopagem Esportivo , Cromatografia Gasosa-Espectrometria de Massas , Detecção do Abuso de Substâncias , Humanos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Detecção do Abuso de Substâncias/métodos , Anabolizantes/urina , Esteroides/urina , Androgênios/urina , Limite de Detecção , Masculino , Esteróides Androgênicos Anabolizantes
3.
Metabolomics ; 19(4): 38, 2023 04 07.
Artigo em Inglês | MEDLINE | ID: mdl-37027080

RESUMO

INTRODUCTION: Despite their ban, Anabolic Androgenic Steroids (AAS) are considered as the most important threat for equine doping purposes. In the context of controlling such practices in horse racing, metabolomics has emerged as a promising alternative strategy to study the effect of a substance on metabolism and to discover new relevant biomarkers of effect. Based on the monitoring of 4 metabolomics derived candidate biomarkers in urine, a prediction model to screen for testosterone esters abuse was previously developed. The present work focuses on assessing the robustness of the associated method and define its scope of application. MATERIALS AND METHODS: Several hundred urine samples were selected from 14 different horses of ethically approved administration studies involving various doping agents' (AAS, SARMS, ß-agonists, SAID, NSAID) (328 urine samples). In addition, 553 urine samples from untreated horses of doping control population were included in the study. Samples were characterized with the previously described LC-HRMS/MS method, with the objective of assessing both its biological and analytical robustness. RESULTS: The study concluded that the measurement of the 4 biomarkers involved in the model was fit for purpose. Further, the classification model confirmed its effectiveness in screening for testosterone esters use; and it demonstrated its ability to screen for the misuse of other anabolic agents, allowing the development of a global screening tool dedicated to this class of substances. Finally, the results were compared to a direct screening method targeting anabolic agents demonstrating complementary performances of traditional and omics approaches in the screening of anabolic agents in horses.


Assuntos
Anabolizantes , Cavalos , Animais , Anabolizantes/urina , Espectrometria de Massas em Tandem/métodos , Esteroides , Metabolômica , Testosterona , Congêneres da Testosterona , Esteróides Androgênicos Anabolizantes , Ésteres , Biomarcadores/urina
4.
Rapid Commun Mass Spectrom ; 35(17): e9141, 2021 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-34106497

RESUMO

RATIONALE: The World Antidoping Agency (WADA) Monitoring program concentrates analytical data from the WADA Accredited Laboratories for substances which are not prohibited but whose potential misuse must be known. The WADA List of Monitoring substances is updated annually, where substances may be removed, introduced or transferred to the Prohibited List, depending on the prevalence of their use. Retroactive processing of old sample datafiles has the potential to create information for the prevalence of use of candidate substances for the Monitoring List in previous years. MetAlign is a freeware software with functionality to reduce the size of liquid chromatography (LC)/high-resolution (HR) full-scan (FS) mass spectrometry (MS) datafiles and to perform a fast search for the presence of substances in thousands of reduced datafiles. METHODS: Validation was performed to the search procedure of MetAlign applied to Anti-Doping Lab Qatar (ADLQ)-screened LC/HR-FS-MS reduced datafiles originated from antidoping samples for tramadol (TRA), ecdysterone (ECDY) and the ECDY metabolite 14-desoxyecdysterone (DESECDY) of the WADA Monitoring List. Searching parameters were related to combinations of accurate masses and retention times (RTs). RESULTS: MetAlign search validation criteria were based on the creation of correct identifications, false positives (FPs) and false negatives (FNs). The search for TRA in 7410 ADLQ routine LC/HR-FS-MS datafiles from the years 2017 to 2020 revealed no false identification (FPs and FNs) compared with the ADLQ WADA reports. ECDY and DESECDY were detected by MetAlign search in approximately 5% of the same cohort of antidoping samples. CONCLUSIONS: MetAlign is a powerful tool for the fast retroactive processing of old reduced datafiles collected in screening by LC/HR-FS-MS to reveal the prevalence of use of antidoping substances. The current study proposed the validation scheme of the MetAlign search procedure, to be implemented per individual substance in the WADA Monitoring program, for the elimination of FNs and FPs.


Assuntos
Anabolizantes/urina , Cromatografia Líquida/métodos , Dopagem Esportivo/métodos , Ecdisterona/urina , Espectrometria de Massas/métodos , Tramadol/urina , Dopagem Esportivo/prevenção & controle , Humanos , Urina/química
5.
Molecules ; 26(5)2021 Mar 03.
Artigo em Inglês | MEDLINE | ID: mdl-33802606

RESUMO

Metandienone and methyltestosterone are orally active anabolic-androgenic steroids with a 17α-methyl structure that are prohibited in sports but are frequently detected in anti-doping analysis. Following the previously reported detection of long-term metabolites with a 17ξ-hydroxymethyl-17ξ-methyl-18-nor-5ξ-androst-13-en-3ξ-ol structure in the chlorinated metandienone analog dehydrochloromethyltestosterone ("oral turinabol"), in this study we investigated the formation of similar metabolites of metandienone and 17α-methyltestosterone with a rearranged D-ring and a fully reduced A-ring. Using a semi-targeted approach including the synthesis of reference compounds, two diastereomeric substances, viz. 17α-hydroxymethyl-17ß-methyl-18-nor-5ß-androst-13-en-3α-ol and its 5α-analog, were identified following an administration of methyltestosterone. In post-administration urines of metandienone, only the 5ß-metabolite was detected. Additionally, 3α,5ß-tetrahydro-epi-methyltestosterone was identified in the urines of both administrations besides the classical metabolites included in the screening procedures. Besides their applicability for anti-doping analysis, the results provide new insights into the metabolism of 17α-methyl steroids with respect to the order of reductions in the A-ring, the participation of different enzymes, and alterations to the D-ring.


Assuntos
Anabolizantes/metabolismo , Anabolizantes/urina , Metandrostenolona/metabolismo , Metandrostenolona/urina , Metiltestosterona/metabolismo , Metiltestosterona/urina , Anabolizantes/química , Cromatografia Gasosa-Espectrometria de Massas , Voluntários Saudáveis , Humanos , Metandrostenolona/química , Metiltestosterona/química , Pessoa de Meia-Idade , Padrões de Referência , Espectrometria de Massas em Tandem
6.
Chemistry ; 25(7): 1740-1745, 2019 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-30427566

RESUMO

Arrayed complexes of a water-soluble deep cavitand and two fluorescent indicators show selective sensing of anabolic-androgenic steroids in aqueous environments. By combining the host-guest complexes with small amounts of heavy metal ions, discrimination between steroids that vary in structure by only a single π bond is possible. The sensing occurs through a triggered aggregation mechanism, which can be mediated by both the presence of metal ions and the steroids. The use of both "turn-on" and "turn-off" fluorophores is essential for good discrimination. As low as 10 µm steroid can be detected, and the discrimination is selective in steroid samples spiked into human urine.


Assuntos
Anabolizantes/urina , Espectrometria de Fluorescência , Congêneres da Testosterona/urina , Anabolizantes/química , Técnicas Biossensoriais , Análise Discriminante , Humanos , Metais Pesados/química , Congêneres da Testosterona/química , Água/química
7.
Rapid Commun Mass Spectrom ; 33(19): 1485-1493, 2019 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-31132805

RESUMO

RATIONALE: Isoflavones are a group of flavonoids that may be of interest in sport doping because they can be used by athletes in the recovery periods after the administration of anabolic steroids, with the aim of increasing the natural production of luteinizing hormone (LH) and, consequently, the biosynthesis of endogenous androgens. METHODS: The in vivo metabolism of methoxyisoflavone (5-methyl-7-methoxyisoflavone) and ipriflavone (7-isopropoxyisoflavone), respectively present in a dietary supplement and in a pharmaceutical preparation, was investigated. The study was carried out by the analysis of urinary samples collected from male Caucasian subjects before, during and after the oral administration of methoxyisoflavone or ipriflavone. After enzymatic hydrolysis and liquid-liquid extraction, all urinary samples were analyzed by gas chromatography/quadrupole time-of-flight (qTOF MS system/qTOF) electron ionization mass spectrometry (EI-MS). RESULTS: Eight metabolites of methoxyisoflavone and six metabolites of ipriflavone were isolated. The corresponding accurate mass spectra are specific for isoflavone structures and revealed also a retro-Diels-Alder fragmentation. CONCLUSIONS: When excreted in large amounts, the urinary metabolites of methoxyisoflavone and ipriflavone can be traced to potential confounding factors in doping analysis. As methoxyisoflavone and ipriflavone have been shown to inhibit the enzyme aromatase, thus interfering with the normal metabolic pathways of testosterone, the detection of their intake, by screening for the presence of their main metabolites in urine, might be helpful in routine doping control analysis.


Assuntos
Anabolizantes/urina , Dopagem Esportivo/métodos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Isoflavonas/urina , Espectrometria de Massas/métodos , Adulto , Anabolizantes/síntese química , Anabolizantes/metabolismo , Humanos , Isoflavonas/síntese química , Isoflavonas/metabolismo , Masculino , Redes e Vias Metabólicas
8.
Rapid Commun Mass Spectrom ; 33(6): 579-586, 2019 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-30589473

RESUMO

RATIONALE: Isotope ratio mass spectrometry (IRMS) is an analytical technique required by the World Antidoping Agency (WADA) before releasing of an adverse finding for the abuse of pseudoendogenous steroids (i.e. testosterone). For every single individual, the delta 13 C values (‰) of the selected target compounds (TCs, i.e. testosterone and/or its precursors/metabolites) are compared with those of endogenous reference compounds (ERCs). The aim of this work is to investigate the individual variation in the delta values of four different commonly used ERCs to establish the maximum acceptable variation, in order to detect potential outliers. METHODS: Routine urine samples collected for antidoping purposes were submitted to IRMS confirmation. After a specific liquid chromatographic purification of the analytes of interest, the final extracts were analyzed by gas chromatography/combustion (GC/C)-IRMS. The selected ERCs monitored were pregnanediol, pregnanetriol, 11-keto-etiocholanolone and 11ß-hydroxyandrosterone. The obtained 13 C delta values were statistically analyzed to evaluate their inter- and intra-individual distribution. RESULTS: The delta values of the ERCs studied showed a normal distribution and no major differences among genders were observed. As expected, there are differences depending on the geographical origin of the samples, reflecting different dietary habits and food sources. The intra-individual dispersion, expressed as the standard deviation (SD) of the values of the studied ERCs, did not greatly exceed the instrumental error (0.5‰), demonstrating the good preservation of the delta values along the metabolic pathway. CONCLUSIONS: For the selected ERCs of non-sporting volunteers and the urinary specimens from more than 1000 sportsmen, we can propose a maximum SD of 0.54‰ and range of 1.2‰ for delta 13 C values as acceptance criteria to detect potential outliers. These cases can be caused by the external masking effect of the administration of a substance modifying the delta values or outliers due to unforeseen procedural artifacts.


Assuntos
Espectrometria de Massas/métodos , Detecção do Abuso de Substâncias/métodos , Adulto , Anabolizantes/urina , Androsterona/análogos & derivados , Androsterona/urina , Isótopos de Carbono , Dopagem Esportivo , Etiocolanolona/análogos & derivados , Etiocolanolona/urina , Feminino , Cromatografia Gasosa-Espectrometria de Massas/métodos , Cromatografia Gasosa-Espectrometria de Massas/normas , Humanos , Masculino , Espectrometria de Massas/normas , Pregnanotriol/urina , Controle de Qualidade , Padrões de Referência , Detecção do Abuso de Substâncias/normas
9.
Br J Clin Pharmacol ; 84(8): 1830-1838, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29722428

RESUMO

AIMS: Salbutamol is used in the management of obstructive bronchospasm, including that of some elite athletes. It is claimed that high salbutamol (oral) doses may also have an anabolic effect. Therefore, inhalation of salbutamol is restricted by the World Anti-Doping Agency (WADA) to a maximal daily dose. Urine is tested for violations, but recent cases have resulted in a debate regarding the validity of this approach. It was our aim to determine whether current approaches are sufficiently able to differentiate approved usage from violations. METHODS: We extracted pharmacokinetic parameters from literature for salbutamol and its sulphated metabolite. From these parameters, a semi-physiological pharmacokinetic model of inhaled and orally administered salbutamol was synthesized, validated against literature data, and used to perform clinical trial simulations (n = 1000) of possible urine concentrations over time resulting from WADA-allowed and oral unacceptable dosages. RESULTS: The synthesized model was able to predict the literature data well. Simulations showed a very large range of salbutamol concentrations, with a significant portion of virtual subjects (15.4%) exceeding the WADA threshold limit of 1000 ng ml-1 at 1 h post-dose. CONCLUSIONS: The observed large variability in urine concentrations indicates that determining the administered dose from a single untimed urine sample is not feasible. The current threshold inadvertently leads to incorrect assumptions of violation, whereas many violations will go unnoticed, especially when samples are taken long after drug administration. These issues, combined with the dubious assertion of its anabolic effect, leads us to conclude that the large effort involved in testing should be reconsidered.


Assuntos
Albuterol/urina , Anabolizantes/urina , Dopagem Esportivo/prevenção & controle , Futilidade Médica , Modelos Biológicos , Administração por Inalação , Administração Oral , Adulto , Albuterol/administração & dosagem , Albuterol/farmacocinética , Anabolizantes/administração & dosagem , Anabolizantes/farmacocinética , Variação Biológica da População/fisiologia , Espasmo Brônquico/tratamento farmacológico , Espasmo Brônquico/urina , Dopagem Esportivo/métodos , Reações Falso-Negativas , Reações Falso-Positivas , Estudos de Viabilidade , Humanos , Eliminação Renal/fisiologia
10.
Org Biomol Chem ; 16(5): 698-702, 2018 01 31.
Artigo em Inglês | MEDLINE | ID: mdl-29319101

RESUMO

Selective androgen receptor modulators (SARMs) are a class of androgen receptor drugs, which have a high potential to be performance enhancers in human and animal sports. Arylpropionamides are one of the major SARM classes and get rapidly metabolized significantly complicating simple detection of misconduct in blood or urine sample analysis. Specific drug-derived metabolites are required as references due to a short half-life of the parent compound but are generally lacking. The difficulty in metabolism studies is the determination of the correct regio and stereoselectivity during metabolic conversion processes. In this study, we have elucidated and verified the chemical structure of two major equine arylpropionamide-based SARM metabolites using a combination of chemical synthesis and liquid chromatography-mass spectrometry (LC-MS) analysis. These synthesized SARM-derived metabolites can readily be utilized as reference standards for routine mass spectrometry-based doping control analysis of at least three commonly used performance-enhancing drugs to unambigously identify misconduct.


Assuntos
Acetamidas/metabolismo , Amidas/metabolismo , Aminofenóis/metabolismo , Anabolizantes/metabolismo , Anilidas/metabolismo , Receptores Androgênicos/metabolismo , Acetamidas/química , Acetamidas/urina , Amidas/química , Amidas/urina , Aminofenóis/química , Aminofenóis/urina , Anabolizantes/química , Anabolizantes/urina , Anilidas/química , Anilidas/urina , Animais , Cromatografia Líquida de Alta Pressão/métodos , Dopagem Esportivo , Cavalos , Humanos , Espectrometria de Massas/métodos , Detecção do Abuso de Substâncias/métodos
11.
Biomed Chromatogr ; 30(4): 555-65, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26268571

RESUMO

The relationships between the ionization profile, sensitivity, and structures of 64 exogenous anabolic steroids (groups I-IV) was investigated under electrospray ionization (ESI) conditions. The target analytes were ionized as [M + H](+) or [M + H-nH2 O](+) in the positive mode, and these ions were used as precursor ions for selected reaction monitoring analysis. The collision energy and Q3 ions were optimized based on the sensitivity and selectivity. The limits of detection (LODs) were 0.05-20 ng/mL for the 64 steroids. The LODs for 38 compounds, 14 compounds and 12 compounds were in the range of 0.05-1, 2-5 and 10-20 ng/mL, respectively. Steroids including the conjugated keto-functional group at C3 showed good proton affinity and stability, and generated the [M + H](+) ion as the most abundant precursor ion. In addition, the LODs of steroids using the [M + H](+) ion as the precursor ion were mostly distributed at low concentrations. In contrast, steroids containing conjugated/unconjugated hydroxyl functional groups at C3 generated [M + H - H2 O](+) or [M + H - 2H2 O](+) ions, and these steroids showed relatively high LODs owing to poor stability and multiple ion formation. An LC-MS/MS method based on the present ionization profile was developed and validated for the determination of 78 steroids (groups I-V) in human urine.


Assuntos
Anabolizantes/urina , Cromatografia Líquida/métodos , Espectrometria de Massas por Ionização por Electrospray/métodos , Esteroides/urina , Anabolizantes/química , Humanos , Íons/química , Limite de Detecção , Esteroides/química , Espectrometria de Massas em Tandem/métodos
12.
Rapid Commun Mass Spectrom ; 29(19): 1779-88, 2015 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-26331928

RESUMO

RATIONALE: The presence in a urinary matrix of a large number of endogenous steroids and corticosteroids with similar structures can hamper the detection of specific exogenous steroids using liquid chromatography/mass spectrometry (LC/MS) with reversed-phase columns. Therefore, the development of LC/MS methods using alternative columns is of great interest. Porous graphitized carbon is a unique stationary phase for high-performance liquid chromatography (HPLC), with properties differing from traditional silica-based and polymeric stationary phases. METHODS: The new method involves enzymatic hydrolysis, liquid-liquid extraction, and determination by high-temperature HPLC/Orbitrap mass spectrometry (HTLC/Orbitrap MS) with atmospheric pressure photoionization (APPI). To achieve APPI of doping substances, the mobile phase consisted of 0.1% CF3COOH (A) and a mixture of acetonitrile/2-propanol (25:75 v/v), containing 0.1% CF3COOH (B), which was used as an effective proton source. RESULTS: A screening method for the detection of 57 exogenous steroids has been developed. The method was validated by spiking 10 different blank urine samples at different concentration levels. Validation parameters included limit of detection (LOD), selectivity, ion suppression, extraction recovery, and repeatability. All studied compounds had an LOD lower than the minimum required performance level. Of the 57 steroids studied, 55 showed recovery better than 70%. For all of the analytes, the relative retention times proved to be stable between days, with relative standard deviations (RSDs) smaller than 0.3%. In addition, the interday RSDs of the peak area ratios ranged between 0.7% and 14.5%. CONCLUSIONS: The proposed method matches the basic requirements of all methods used to analyze drugs or metabolites in an antidoping laboratory, i.e., sensitivity, selectivity, and specificity. The acquisition of full-scan mass spectra with accurate masses can be a valuable tool in the retrospective evaluation of analyzed samples for anabolic steroids recently added to the prohibited list.


Assuntos
Anabolizantes/urina , Espectrometria de Massas/métodos , Cromatografia Líquida de Alta Pressão/métodos , Dopagem Esportivo , Grafite/química , Temperatura Alta , Humanos , Masculino , Porosidade
13.
Anal Bioanal Chem ; 407(15): 4397-409, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25503937

RESUMO

In order to detect the misuse of endogenous anabolic steroids, doping control laboratories require methods that allow differentiation between endogenous steroids and their synthetic copies. Gas chromatography combustion isotope ratio mass spectrometry (GC-C-IRMS) is capable of measuring the carbon isotope ratio of urinary steroids and this allows differentiation between both. GC-C-IRMS and its application to doping control has evolved a lot during the last decade and so have the World Anti-Doping Agency (WADA) technical documents that describe how GC-C-IRMS should be applied. Especially the WADA technical document of 2014 introduced a number of obligatory quality controls and a fixed methodology that should be used by all the doping control laboratories. This document imposed more uniform methods between the laboratories in order to decrease the interlaboratory standard deviation and acquire similar results for the analysis of the same urine samples. In this paper, 3 years of drug testing data of our GC-C-IRMS method in routine doping control practice is described, with an emphasis on the new WADA technical document and its implementation. Useful data for other doping control laboratories is presented focussing on general method setup, quality control and data collected from routine samples. The paper concentrates on how IRMS results shift or remain similar by switching to the 2014 WADA technical document and gives insight in a straightforward approach to calculate the measurement uncertainty.


Assuntos
Anabolizantes/urina , Cromatografia Gasosa-Espectrometria de Massas/métodos , Esteroides/urina , Detecção do Abuso de Substâncias/métodos , Adulto , Dopagem Esportivo , Feminino , Humanos , Masculino , Controle de Qualidade , Adulto Jovem
14.
Anal Bioanal Chem ; 407(15): 4473-84, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25736246

RESUMO

Profiling conjugated urinary steroids to detect anabolic-steroid misuse is recognized as an efficient analytical strategy in both chemical-food-safety and anti-doping fields. The relevance and robustness of such profiling rely on the analysis of glucuronide and sulfate steroids, which is expected to have properties including accuracy, specificity, sensitivity, and, if possible, rapidity. In this context, the ability of ultra-high-performance supercritical-fluid chromatography (UHPSFC) hyphenated tandem mass spectrometry (MS-MS) to provide reliable and accurate phase II analysis of steroids was assessed. Four stationary phases with sub-2 µm particles (BEH, BEH 2-ethyl-pyridine, HSS C18 SB, and CSH fluorophenyl) were screened for their capacity to separate several conjugated steroid isomers. Analytical conditions including stationary phase, modifier composition and percentage, back pressure, column temperature, and composition and flow rate of make-up solvent were investigated to improve the separation and/or the sensitivity. Thus, an analytical procedure enabling the analysis of eight glucuronide and 12 sulfate steroids by two different methods in 12 and 15 min, respectively, was optimized. The two procedures were evaluated, and UHPSFC-MS-MS analysis revealed its ability to provide sensitive (limits of quantification: 0.1 ng mL(-1) and 0.5 ng mL(-1) for sulfate and glucuronide steroids, respectively) and reliable quantitative performance (R(2) > 0.995, RSD < 20%, and bias < 30%) through the use of suitable labeled internal standards. Comparison with UHPLC-MS-MS was performed, and UHPSFC-MS-MS obtained better performance in terms of sensitivity. Finally, as a proof of concept, this so-called green technology was used in a chemical-food-safety context to profile steroid conjugates in urine samples from bovines treated with estradiol. Graphical Abstract Glucuronide and sulfate steroids analysis in urine by ultra-high performance supercritical fluid chromatography hyphenated tandem mass spectrometry.


Assuntos
Anabolizantes/urina , Bovinos/urina , Cromatografia Líquida de Alta Pressão/métodos , Estradiol/urina , Glucuronídeos/urina , Esteroides/urina , Espectrometria de Massas em Tandem/métodos , Animais , Limite de Detecção , Sulfatos/urina
15.
Anal Bioanal Chem ; 407(15): 4385-96, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25595834

RESUMO

Doping control is a main priority for regulatory bodies of both the horse racing industry and the equestrian sports. Urine and blood samples are screened for the presence of hundreds of forbidden substances including anabolic-androgenic steroids (AASs). Based on the suspected endogenous origin of some AASs, with ß-boldenone as the most illicit candidate, this study aimed to improve the knowledge of the naturally present AAS in horse urine. To this extent, a novel ultra high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method was developed and validated according to the Association of Official Racing Chemists (AORC) and European Commission (EC) guidelines, proving the power of this new method. Low limits of detection (0.2 ng/mL), good reproducibility (percentage of standard deviation (%RSD) < 10%), high recovery (94.6 to 117.1%), selectivity and specificity, and a linear response (confirmed with R(2) > 0.99 and lack-of-fit analysis) were obtained for all included AASs. With this method, urine samples of 105 guaranteed untreated horses (47 geldings, 53 mares, and 5 stallions serving as a control) were screened for ß-boldenone and five related natural steroids: androstadienedione (ADD), androstenedione (AED), alpha-testosterone (αT), beta-testosterone (ßT), and progesterone (P). Progesterone, ß-testosterone, and α-testosterone were detected in more than half of the horses at low concentrations (<2 ng/mL). Occasionally, not only testosterone and progesterone but also low concentrations of AED, ADD, and boldenone (Bol) were found (0.5-5 ng/mL). Graphical Abstract A sensitive, new and fully validated UHPLC-MS/MS method has been developed that is able to quantify low levels of anabolic-androgenic steroids naturally present in urine of untreated horses (mares and geldings).


Assuntos
Anabolizantes/urina , Androgênios/urina , Cromatografia Líquida de Alta Pressão/métodos , Cavalos/urina , Esteroides/urina , Espectrometria de Massas em Tandem/métodos , Testosterona/análogos & derivados , Animais , Dopagem Esportivo , Feminino , Limite de Detecção , Masculino , Reprodutibilidade dos Testes , Detecção do Abuso de Substâncias/métodos , Testosterona/urina
16.
Drug Test Anal ; 16(2): 112-126, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37264746

RESUMO

Boldenone is an anabolic-androgenic steroid (AAS) that is prohibited in equine sports. However, in certain situations, it is endogenous, potentially formed by the microbes in urine. An approach to the differentiation based on the detection of the biomarkers Δ1-progesterone, 20(S)-hydroxy-Δ1-progesterone and 20(S)-hydroxyprogesterone was assessed, and their concentrations were monitored in the urine of untreated female horses (n = 291) alongside boldenone, boldienone, testosterone and androstenedione. Using an ultra-sensitive analytical method, boldenone (256 ± 236 pg/mL, n = 290) and the biomarkers (Δ1-progesterone up to 57.6 pg/mL, n = 8; 20(S)-hydroxy-Δ1-progesterone 85.3 ± 181 pg/mL, n = 130; 20(S)-hydroxyprogesterone 43.5 ± 92.1 pg/mL, n = 158) were detected at low concentrations. The ex vivo production of Δ1-steroids was artificially induced following the storage of urine samples at room temperature for 7 days in order to assess the concentrations and ratios of the monitored steroids. The administration of inappropriately stored feed source also resulted in an increase in 20(S)-hydroxy-Δ1-progesterone concentrations and the biomarker ratios. Using the results from different datasets, an approach to differentiation was developed. In situations where the presence of boldenone exceeds a proposed action limit of 5 ng/mL, the presence of the biomarkers would be investigated. If Δ1-progesterone is above 50 pg/mL or if 20(S)-hydroxy-Δ1-progesterone is above 100 pg/mL with the ratio of 20(S)-hydroxy-Δ1-progesterone:20(S)-hydroxyprogesterone greater than 5:1, then this would indicate ex vivo transformation or consumption of altered feed rather than steroid administration. There remains a (small) possibility of a false negative result, but the model increases confidence that adverse analytical findings reported in female horses are caused by AAS administrations.


Assuntos
Anabolizantes , Dopagem Esportivo , Cavalos , Animais , Feminino , Progesterona , Anabolizantes/urina , Testosterona/urina , Esteroides , Hidroxiprogesteronas , Biomarcadores
17.
Clin Chim Acta ; 557: 117871, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38467244

RESUMO

Ostarine, also known as MK-2866 or enobosarm, is a selective androgen receptor modulator (SARM). It has anabolic properties and as such is widely used in doping, accounting in 2021 for 25 % of the adverse analytical findings (AAF) among the class S1.2 "Other anabolic agents" of products banned by the World Anti-Doping Agency, to which it belongs. But in some cases, it can be responsible for an AAF following contamination. We report the case of an athlete who contaminated herself by exchanging body fluids while kissing her boyfriend, who took 25 mg per day of MK-2866 for 9 days prior to the athlete's AAF (urinary concentration evaluated at 13 ng/mL) without her knowledge. Both subjects came to our lab for hair testing. The athlete's hair was black and slightly frizzy. Six segments of 2 cm then 7 × 3 cm (33 cm) were analysed and showed increasing concentrations, from 2 pg/mg on the first segment to 17.8 pg/mg on the last segment. The boyfriend's hair, light-brown, analyzed on 4 × 2 cm, also showed increasing values, from 65 to 143 pg/mg. These gradients of concentration in the hair's athlete and in her boyfriend were compatible with external contamination of the hair, confirmed by analysis of washing baths, pillowcases (150 pg on each), and the athlete's hairbrush (250 pg). Fingernails were also contaminated, with 21 pg/mg in the athlete and 1041 pg/mg in the boyfriend, with highly contaminated washing baths, and toenails were less contaminated, with 2 pg/mg in the athlete and 17.3 pg/mg in the boyfriend. Urine samples taken 35 days after the start of MK-2866 treatment showed a value of 3690 ng/mL in the boyfriend and 5.7 ng/mL in the athlete. After 6 days off, these concentrations were 3.3 ng/mL and 0.1 ng/mL, respectively. A controlled transfer study was carried out 12 days after discontinuation (urine concentrations returned to negative level). After administration of 17 mg (the 25 mg/mL vial having been controlled at 17 mg/mL), urine samples were taken from the boyfriend and the athlete (n = 10 for each) for more than 25 h after they had been living normally with each other (regular kissing in particular). The boyfriend's urine concentrations ranged from 681 ng/mL to 12822 ng/mL (Tmax = 8:30 hrs), and the athlete's from 0.3 ng/mL to 13 ng/mL with Tmax = 8:30 hrs, i.e. at 22:30 hrs, which corresponded exactly to the time of collection of the urine that showed AAF, with a similar concentration. The dose ingested by the athlete was estimated at 15 µg. These results demonstrate the transfer of ostarine via body fluids between two subjects, with a high risk of AAF in one athlete, as observed in our case.


Assuntos
Anabolizantes , Líquidos Corporais , Dopagem Esportivo , Feminino , Humanos , Anabolizantes/urina , Anilidas , Líquidos Corporais/química , Detecção do Abuso de Substâncias/métodos , Masculino
18.
J Chromatogr A ; 1727: 464993, 2024 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-38759462

RESUMO

Anabolic steroids and ß-agonists are commonly prohibited substances found in doping control studies; therefore, the determination of anabolic substances in biological samples is crucial. To analyze the anabolic compounds in urine, an adsorbent, polyethylene glycol (PEG)-grafted magnetic nanoparticle material (Fe3O4@SiO2-PEG), with low toxicity and strong biocompatibility was prepared in this investigation. Compared to those of Fe3O4 and Fe3O4@SiO2, the grafted PEG chains (approximately 5.4 wt.%) on the magnetic nanoparticles improved the extraction efficiencies by factors of 3.9-17.0 and 2.5-2.9, respectively, likely due to the electrostatic attraction and hydrogen bonding. To achieve maximum extraction efficiency, several extraction parameters were optimized, including the kind and volume of desorption solvent, pH, and the extraction and desorption time. The standard curves were linear within the range of 0.5-20 µg/L for methyltestosterone and trenbolone, and 0.02-5 µg/L for clenbuterol. The limits of detection for the three drugs were 0.01-0.12 µg/L. The limits of quantification were 0.02-0.40 µg/L. The levels of precision of the optimized method were assessed based on the respective intra- and inter-day and batch-to-batch relative standard deviations in the ranges of 3.2-5.2 % (n = 5), 5.9-11.3 % (n = 4), and 6.7-9.2 % (n = 3). The Fe3O4@SiO2-PEG nanoparticles could exclude urine matrix interferences (matrix effect of 91.8-98.1 %) and achieve satisfactory recoveries (75.5-116.1 %), affording sensitive and accurate determination of trace anabolic substances in urine.


Assuntos
Anabolizantes , Limite de Detecção , Nanopartículas de Magnetita , Polietilenoglicóis , Humanos , Polietilenoglicóis/química , Anabolizantes/urina , Anabolizantes/isolamento & purificação , Nanopartículas de Magnetita/química , Dopagem Esportivo , Adsorção , Reprodutibilidade dos Testes , Extração em Fase Sólida/métodos , Dióxido de Silício/química
19.
Artigo em Inglês | MEDLINE | ID: mdl-38581929

RESUMO

Nandrolone (NT) is a type of androgen anabolic steroid that is often illegally used in cattle farming, leading to unpredictable harm to human health via the food chain. In this study, a rapid detection method for NT in the samples of cattle farming was established using a portable mass spectrometer. The instrument parameters were optimized, including a thermal desorption temperature of 220 °C, a pump speed of 30 %, an APCI ionization voltage of 3900 v, and an injection volume of 6 µL. The samples of bovine urine, feed, sewage, and tissue were selected, and extracted using a solution of methanol:acetonitrile (1:1, v/v), followed by spiking a NT standard solution (1000 ng·mL-1) and ionization through the APCI ion source for detection. The results showed that NT could not be detected in beef and feed due to the complexity of the matrix, while clear signals of NT ions were observed in bovine urine and sewage samples, with LODs of 1000 and 100 ng·mL-1, respectively. Furthermore, quantitative analysis was attempted, and a good linear relationship (R2 = 0.9952) was observed for NT in sewage within the range of 100 to 1000 ng·mL-1. At spiked levels of 100, 500, 1000 and 2000 ng mL-1, the recovery rates ranged from 74.3 % to 92.8 %, with a relative standard deviation (n = 6) of less than 15 %. In conclusion, this detection method offers the advantages of simplicity, rapidity, strong timeliness, and specificity, making it suitable for on-site detection. It can be used for qualitative screening of nandrolone in bovine urine and quantitative analysis of nandrolone in sewage.


Assuntos
Limite de Detecção , Nandrolona , Bovinos , Animais , Nandrolona/análise , Nandrolona/urina , Modelos Lineares , Reprodutibilidade dos Testes , Espectrometria de Massas/métodos , Esgotos/química , Esgotos/análise , Ração Animal/análise , Anabolizantes/urina , Anabolizantes/análise
20.
Rapid Commun Mass Spectrom ; 27(17): 1904-12, 2013 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-23939956

RESUMO

RATIONALE: In sports drug testing, comprehensive studies on the metabolism of therapeutic agents with misuse potential are necessary to identify metabolites that provide utmost retrospectivity and specificity. By commonly employed approaches minor and/or long-term metabolites in urine might remain undetected. Hence, an alternative strategy to unambiguously identify the majority of urinary metabolites including low-abundance representatives is desirable. METHODS: Urine samples were collected for 20 days during an elimination study with an oral dose of 5 mg of 17α-C(2)H3-metandienone. The specimens were processed according to established sample preparation procedures (including fractionation and deconjugation) and subjected to gas chromatography/hydrogen isotope ratio mass spectrometry (GC/IRMS) analysis. Due to the deuteration of the administered drug, urinary metabolites bearing the deuterium label yield abundant and specific signals on the GC/IRMS instrument resulting from the substantially altered (2)H/(1)H ratio. The sample aliquots were measured by gas chromatography/time-of-flight (GC/Q-TOF) mass spectrometry using identical GC conditions, allowing high-resolution/high-accuracy mass data to be obtained on all urinary metabolites previously identified by IRMS. RESULTS: Within the IRMS chromatograms, labeled metabolites were identified up to 20 days after administration at urinary concentration down to 0.25 ng/mL. More than 50 metabolites were observed with the earlier described long-term metabolite of metandienone, 18-nor-17ß-hyroxymethyl,17α-methyl-androst-1,4,13-trien-3-one, being the most prominent glucuronidated metabolite in the studied time window. In the sulfoconjugated steroids fraction, a yet unknown metabolite was observed at m/z 283.1997 comprising the experimentally determined elemental composition of C20H21(2)H3O. CONCLUSIONS: Combining IRMS with high-resolution mass spectrometry considerably facilitates and accelerates metabolite identification of deuterium-labeled compounds in urine. Of particular relevance in doping control, the principle is applicable also to other arenas of drug research, allowing the preparation and administration of e.g. radioactively labeled substances to be omitted.


Assuntos
Anabolizantes/química , Anabolizantes/metabolismo , Cromatografia Gasosa/métodos , Espectrometria de Massas/métodos , Detecção do Abuso de Substâncias/métodos , Anabolizantes/urina , Dopagem Esportivo/prevenção & controle , Humanos , Masculino , Pessoa de Meia-Idade , Estrutura Molecular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA