Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 95
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Digit Imaging ; 34(6): 1376-1386, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34647199

RESUMEN

When preprocedural images are overlaid on intraprocedural images, interventional procedures benefit in that more structures are revealed in intraprocedural imaging. However, image artifacts, respiratory motion, and challenging scenarios could limit the accuracy of multimodality image registration necessary before image overlay. Ensuring the accuracy of registration during interventional procedures is therefore critically important. The goal of this study was to develop a novel framework that has the ability to assess the quality (i.e., accuracy) of nonrigid multimodality image registration accurately in near real time. We constructed a solution using registration quality metrics that can be computed rapidly and combined to form a single binary assessment of image registration quality as either successful or poor. Based on expert-generated quality metrics as ground truth, we used a supervised learning method to train and test this system on existing clinical data. Using the trained quality classifier, the proposed framework identified successful image registration cases with an accuracy of 81.5%. The current implementation produced the classification result in 5.5 s, fast enough for typical interventional radiology procedures. Using supervised learning, we have shown that the described framework could enable a clinician to obtain confirmation or caution of registration results during clinical procedures.


Asunto(s)
Diagnóstico por Imagen , Aprendizaje Automático Supervisado , Algoritmos , Humanos , Procesamiento de Imagen Asistido por Computador , Movimiento (Física)
2.
IEEE Sens J ; 17(7): 1952-1963, 2017 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-28652857

RESUMEN

Magnetic Resonance Imaging (MRI) provides both anatomical imaging with excellent soft tissue contrast and functional MRI imaging (fMRI) of physiological parameters. The last two decades have witnessed the manifestation of increased interest in MRI-guided minimally invasive intervention procedures and fMRI for rehabilitation and neuroscience research. Accompanying the aspiration to utilize MRI to provide imaging feedback during interventions and brain activity for neuroscience study, there is an accumulated effort to utilize force sensors compatible with the MRI environment to meet the growing demand of these procedures, with the goal of enhanced interventional safety and accuracy, improved efficacy and rehabilitation outcome. This paper summarizes the fundamental principles, the state of the art development and challenges of fiber optic force sensors for MRI-guided interventions and rehabilitation. It provides an overview of MRI-compatible fiber optic force sensors based on different sensing principles, including light intensity modulation, wavelength modulation, and phase modulation. Extensive design prototypes are reviewed to illustrate the detailed implementation of these principles. Advantages and disadvantages of the sensor designs are compared and analyzed. A perspective on the future development of fiber optic sensors is also presented which may have additional broad clinical applications. Future surgical interventions or rehabilitation will rely on intelligent force sensors to provide situational awareness to augment or complement human perception in these procedures.

3.
Radiology ; 274(1): 170-80, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25222067

RESUMEN

PURPOSE: To determine the detection rate, clinical relevance, Gleason grade, and location of prostate cancer ( PCa prostate cancer ) diagnosed with and the safety of an in-bore transperineal 3-T magnetic resonance (MR) imaging-guided prostate biopsy in a clinically heterogeneous patient population. MATERIALS AND METHODS: This prospective retrospectively analyzed study was HIPAA compliant and institutional review board approved, and informed consent was obtained. Eighty-seven men (mean age, 66.2 years ± 6.9) underwent multiparametric endorectal prostate MR imaging at 3 T and transperineal MR imaging-guided biopsy. Three subgroups of patients with at least one lesion suspicious for cancer were included: men with no prior PCa prostate cancer diagnosis, men with PCa prostate cancer who were undergoing active surveillance, and men with treated PCa prostate cancer and suspected recurrence. Exclusion criteria were prior prostatectomy and/or contraindication to 3-T MR imaging. The transperineal MR imaging-guided biopsy was performed in a 70-cm wide-bore 3-T device. Overall patient biopsy outcomes, cancer detection rates, Gleason grade, and location for each subgroup were evaluated and statistically compared by using χ(2) and one-way analysis of variance followed by Tukey honestly significant difference post hoc comparisons. RESULTS: Ninety biopsy procedures were performed with no serious adverse events, with a mean of 3.7 targets sampled per gland. Cancer was detected in 51 (56.7%) men: 48.1% (25 of 52) with no prior PCa prostate cancer , 61.5% (eight of 13) under active surveillance, and 72.0% (18 of 25) in whom recurrence was suspected. Gleason pattern 4 or higher was diagnosed in 78.1% (25 of 32) in the no prior PCa prostate cancer and active surveillance groups. Gleason scores were not assigned in the suspected recurrence group. MR targets located in the anterior prostate had the highest cancer yield (40 of 64, 62.5%) compared with those for the other parts of the prostate (P < .001). CONCLUSION: In-bore 3-T transperineal MR imaging-guided biopsy, with a mean of 3.7 targets per gland, allowed detection of many clinically relevant cancers, many of which were located anteriorly.


Asunto(s)
Biopsia Guiada por Imagen , Imagen por Resonancia Magnética Intervencional/métodos , Neoplasias de la Próstata/patología , Anciano , Medios de Contraste , Gadolinio DTPA , Humanos , Interpretación de Imagen Asistida por Computador , Masculino , Persona de Mediana Edad , Perineo , Estudios Prospectivos
4.
J Magn Reson Imaging ; 42(1): 63-71, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25263213

RESUMEN

PURPOSE: To demonstrate the utility of a robotic needle-guidance template device as compared to a manual template for in-bore 3T transperineal magnetic resonance imaging (MRI)-guided prostate biopsy. MATERIALS AND METHODS: This two-arm mixed retrospective-prospective study included 99 cases of targeted transperineal prostate biopsies. The biopsy needles were aimed at suspicious foci noted on multiparametric 3T MRI using manual template (historical control) as compared with a robotic template. The following data were obtained: the accuracy of average and closest needle placement to the focus, histologic yield, percentage of cancer volume in positive core samples, complication rate, and time to complete the procedure. RESULTS: In all, 56 cases were performed using the manual template and 43 cases were performed using the robotic template. The mean accuracy of the best needle placement attempt was higher in the robotic group (2.39 mm) than the manual group (3.71 mm, P < 0.027). The mean core procedure time was shorter in the robotic (90.82 min) than the manual group (100.63 min, P < 0.030). Percentage of cancer volume in positive core samples was higher in the robotic group (P < 0.001). Cancer yields and complication rates were not statistically different between the two subgroups (P = 0.557 and P = 0.172, respectively). CONCLUSION: The robotic needle-guidance template helps accurate placement of biopsy needles in MRI-guided core biopsy of prostate cancer.


Asunto(s)
Marcadores Fiduciales , Biopsia Guiada por Imagen/instrumentación , Imagen por Resonancia Magnética Intervencional/instrumentación , Neoplasias de la Próstata/patología , Robótica/instrumentación , Anciano , Anciano de 80 o más Años , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Biopsia Guiada por Imagen/métodos , Imagen por Resonancia Magnética Intervencional/métodos , Masculino , Persona de Mediana Edad , Perineo/patología , Reproducibilidad de los Resultados , Robótica/métodos , Sensibilidad y Especificidad
5.
J Oral Maxillofac Surg ; 73(10): 2005-16, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25865717

RESUMEN

PURPOSE: To assess the accuracy of a novel navigation system for maxillofacial surgery using human cadavers and a live minipig model. MATERIALS AND METHODS: We tested an electromagnetic tracking system (OsteoMark-Navigation) that uses simple sensors to determine the position and orientation of a hand-held pencil-like marking device. The device can translate 3-dimensional computed tomographic data intraoperatively to allow the surgeon to localize and draw a proposed osteotomy or the resection margins of a tumor on bone. The accuracy of the OsteoMark-Navigation system in locating and marking osteotomies and screw positions in human cadaver heads was assessed. In group 1 (n = 3, 6 sides), OsteoMark-Navigation marked osteotomies and screw positions were compared to virtual treatment plans. In group 2 (n = 3, 6 sides), marked osteotomies and screw positions for distraction osteogenesis devices were compared with those performed using fabricated guide stents. Three metrics were used to document the precision and accuracy. In group 3 (n = 1), the system was tested in a standard operating room environment. RESULTS: For group 1, the mean error between the points was 0.7 mm (horizontal) and 1.7 mm (vertical). Compared with the posterior and inferior mandibular border, the mean error was 1.2 and 1.7 mm, respectively. For group 2, the mean discrepancy between the points marked using the OsteoMark-Navigation system and the surgical guides was 1.9 mm (range 0 to 4.1). The system maintained accuracy on a live minipig in a standard operating room environment. CONCLUSION: Based on this research OsteoMark-Navigation is a potentially powerful tool for clinical use in maxillofacial surgery. It has accuracy and precision comparable to that of existing clinical applications.


Asunto(s)
Cirugía Bucal/instrumentación , Animales , Cadáver , Humanos , Reproducibilidad de los Resultados , Porcinos , Porcinos Enanos
6.
IEEE ASME Trans Mechatron ; 20(5): 2252-2263, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26380544

RESUMEN

In this paper, we present a tendon-driven continuum robot for endoscopic surgery. The robot has two sections for articulation actuated by tendon wires. By actuating the two sections independently, the robot can generate a variety of tip positions while maintaining the tip direction. This feature offers more flexibility in positioning the tip for large viewing angles of up to 180 degrees than does a conventional endoscope. To accurately estimate the tip position at large viewing angles, we employed kinematic mapping with a tension propagation model including friction between the tendon wires and the robot body. In a simulation study using this kinematic-mapping, the two-section robot at a target scale (outer diameter 1.7 mm and length 60 mm) produced a variety of tip positions within 50-mm ranges at the 180°-angle view. In the experimental validation, a 10:1 scale prototype performed three salient postures with different tip positions at the 180°-angle view. The proposed forward kinematic mapping (FKM) predicted the tip position within a tip-to-tip error of 6 mm over the 208-mm articulating length. The tip-to-tip error by FKM was significantly less than the one by conventional piecewise-constant-curvature approximation (PCCA) (FKM: 5.9 ± 2.9 mm vs. PCCA: 23.7 ± 3.6 mm, n=15, P < 0.01).

7.
IEEE ASME Trans Mechatron ; 20(4): 1920-1932, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26412962

RESUMEN

This paper presents a fully-actuated robotic system for percutaneous prostate therapy under continuously acquired live magnetic resonance imaging (MRI) guidance. The system is composed of modular hardware and software to support the surgical workflow of intra-operative MRI-guided surgical procedures. We present the development of a 6-degree-of-freedom (DOF) needle placement robot for transperineal prostate interventions. The robot consists of a 3-DOF needle driver module and a 3-DOF Cartesian motion module. The needle driver provides needle cannula translation and rotation (2-DOF) and stylet translation (1-DOF). A custom robot controller consisting of multiple piezoelectric motor drivers provides precision closed-loop control of piezoelectric motors and enables simultaneous robot motion and MR imaging. The developed modular robot control interface software performs image-based registration, kinematics calculation, and exchanges robot commands and coordinates between the navigation software and the robot controller with a new implementation of the open network communication protocol OpenIGTLink. Comprehensive compatibility of the robot is evaluated inside a 3-Tesla MRI scanner using standard imaging sequences and the signal-to-noise ratio (SNR) loss is limited to 15%. The image deterioration due to the present and motion of robot demonstrates unobservable image interference. Twenty-five targeted needle placements inside gelatin phantoms utilizing an 18-gauge ceramic needle demonstrated 0.87 mm root mean square (RMS) error in 3D Euclidean distance based on MRI volume segmentation of the image-guided robotic needle placement procedure.

8.
Arthrosc Sports Med Rehabil ; 6(2): 100855, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38328532

RESUMEN

Purpose: To investigate the relationship between the supratrochlear rim and isolated patellar chondromalacia (PC) using magnetic resonance imaging (MRI) scans of the knee. Methods: Patients without patellofemoral pain (control group) and patients with patellofemoral pain and diagnosed with stage III or IV PC based on MRI (defect group) were retrospectively identified. Patients with a history of patellar subluxation were excluded. We used patient MRI scans to perform 20 anatomical measurements of the patellofemoral joint. We also performed 2 measurements of the anterior femoral curvature. A total of 30 patients (29 ± 8.7 years) were in the control group, and 20 patients were in the defect group (29.4 ± 9.7 years). Results: The maximum curvature (P < .001) and mean curvature (P < .001) of the anterior femoral condyle were found statistically significantly different between the groups. Patellotrochlear index (P = .03) and Insall-Salvati index (P < .001) were also found statistically significantly different between the 2 groups. Patella type III and trochlear dysplasia grade B were found more common in the defect group. Conclusions: In this Level III prognostic, case-control study, we have shown through MRI knee measurements that the isolated patellar chondromalacia in patients without a history of patellar subluxation and dislocation is correlated with the increased anterior femoral curvature in combination with patella alta.

9.
Artículo en Inglés | MEDLINE | ID: mdl-38890223

RESUMEN

PURPOSE: Considering the recent implementation of lung cancer screening guidelines, it is crucial that small pulmonary nodules are accurately diagnosed. There is a significant need for quick, precise, and minimally invasive biopsy methods, especially for patients with small lung lesions in the outer periphery. Robotic bronchoscopy (RB) has recently emerged as a novel solution. The purpose of this study was to evaluate the accuracy of RB compared to the existing standard, electromagnetic navigational bronchoscopy (EM-NB). METHODS: A prospective, single-blinded, and randomized-controlled study was performed to compare the accuracy of RB to EM-NB in localizing and targeting pulmonary lesions in a porcine lung model. Four operators were tasked with navigating to four pulmonary targets in the outer periphery of a porcine lung, to which they were blinded, using both the RB and EM-NB systems. The dependent variable was accuracy. Accuracy was measured as a rate of success in lesion localization and targeting, the distance from the center of the pulmonary target, and by anatomic location. The independent variable was the navigation system, RB was compared to EM-NB using 1:1 randomization. RESULTS: Of 75 attempts, 72 were successful in lesion localization and 60 were successful in lesion targeting. The success rate for lesion localization was 100% with RB and 91% with EM- NB. The success rate for lesion targeting was 93% with RB and 80% for EM-NB. RB demonstrated superior accuracy in reaching the distance from the center of the lesion, at 0.62 mm compared to EM-NB at 1.28 mm (p = 0.001). Accuracy was improved using RB compared to EM- NB for lesions in the LLL (p = 0.025), LUL (p < 0.001), and RUL (p < 0.001). CONCLUSION: Our findings support RB as a more accurate method of navigating and localizing small peripheral pulmonary targets when compared to standard EM-NB in a porcine lung model. This may be attributed to the ability of RB to reduce substantial tissue displacement seen with standard EM-NB navigation. As the development and application of RB advances, so will the ability to accurately diagnose small peripheral lung cancer nodules, providing patients with early-stage lung cancer the best possible outcomes.

10.
Int J Comput Assist Radiol Surg ; 18(3): 449-460, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36152168

RESUMEN

PURPOSE: Understanding the three-dimensional anatomy of percutaneous intervention in prostate cancer is essential to avoid complications. Recently, attempts have been made to use machine learning to automate the segmentation of functional structures such as the prostate gland, rectum, and bladder. However, a paucity of material is available to segment extracapsular structures that are known to cause needle deflection during percutaneous interventions. This research aims to explore the feasibility of the automatic segmentation of prostate and extracapsular structures to predict needle deflection. METHODS: Using pelvic magnetic resonance imagings (MRIs), 3D U-Net was trained and optimized for the prostate and extracapsular structures (bladder, rectum, pubic bone, pelvic diaphragm muscle, bulbospongiosus muscle, bull of the penis, ischiocavernosus muscle, crus of the penis, transverse perineal muscle, obturator internus muscle, and seminal vesicle). The segmentation accuracy was validated by putting intra-procedural MRIs into the 3D U-Net to segment the prostate and extracapsular structures in the image. Then, the segmented structures were used to predict deflected needle path in in-bore MRI-guided biopsy using a model-based approach. RESULTS: The 3D U-Net yielded Dice scores to parenchymal organs (0.61-0.83), such as prostate, bladder, rectum, bulb of the penis, crus of the penis, but lower in muscle structures (0.03-0.31), except and obturator internus muscle (0.71). The 3D U-Net showed higher Dice scores for functional structures ([Formula: see text]0.001) and complication-related structures ([Formula: see text]0.001). The segmentation of extracapsular anatomies helped to predict the deflected needle path in MRI-guided prostate interventions of the prostate with the accuracy of 0.9 to 4.9 mm. CONCLUSION: Our segmentation method using 3D U-Net provided an accurate anatomical understanding of the prostate and extracapsular structures. In addition, our method was suitable for segmenting functional and complication-related structures. Finally, 3D images of the prostate and extracapsular structures could simulate the needle pathway to predict needle deflections.


Asunto(s)
Pelvis , Próstata , Humanos , Masculino , Animales , Bovinos , Recto , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Procesamiento de Imagen Asistido por Computador/métodos
11.
Int J Comput Assist Radiol Surg ; 18(4): 707-713, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36528684

RESUMEN

PURPOSE: Airway Stenosis (AS) is a condition of airway narrowing in the expiration phase. Bronchoscopy is a minimally invasive pulmonary procedure used to diagnose and/or treat AS. The AS quantification in a form of the Stenosis Index (SI), whether subjective or digital, is necessary for the physician to decide on the most appropriate form of treatment. The literature reports that the subjective SI estimation is inaccurate. In this paper, we propose an approach to quantify the SI defining the level of airway narrowing, using depth estimation from a bronchoscopic image. METHODS: In this approach we combined a generative depth estimation technique combined with depth thresholding to provide Computer-based AS quantification. We performed an interim clinical analysis by comparing AS quantification performance of three expert bronchoscopists against the proposed Computer-based method on seven patient datasets. RESULTS: The Mean Absolute Error of the subjective Human-based and the proposed Computer-based SI estimation was [Formula: see text] [%] and [Formula: see text] [%], respectively. The correlation coefficients between the CT measurements were used as the gold standard, and the Human-based and Computer-based SI estimation were [Formula: see text] and 0.46, respectively. CONCLUSIONS: We presented a new computer method to quantify the severity of AS in bronchoscopy using depth estimation and compared the performance of the method against a human-based approach. The obtained results suggest that the proposed Computer-based AS quantification is a feasible tool that has the potential to provide significant assistance to physicians in bronchoscopy.


Asunto(s)
Broncoscopía , Computadores , Humanos , Constricción Patológica/diagnóstico , Estudios de Factibilidad , Broncoscopía/métodos
12.
Int J Comput Assist Radiol Surg ; 18(2): 247-255, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35986830

RESUMEN

PURPOSE: The bronchoscopist's ability to locate the lesion with the bronchoscope is critical for a transbronchial biopsy. However, much less study has been done on the transbronchial biopsy route. This study aims to determine whether the geometrical attributes of the bronchial route can predict the difficulty of reaching tumors in bronchoscopic intervention. METHODS: This study included patients who underwent bronchoscopic diagnosis of lung tumors using electromagnetic navigation. The biopsy instrument was considered "reached" and recorded as such if the tip of the tracked bronchoscope or extended working channel was in the tumors. Four geometrical indices were defined: Local curvature (LC), plane rotation (PR), radius, and global relative angle. A Mann-Whitney U test and logistic regression analysis were performed to analyze the difference in geometrical indices between the reachable and unreachable groups. Receiver operating characteristic analysis (ROC) was performed to evaluate the geometrical indices to predict reachability. RESULTS: Of the 41 patients enrolled in the study, 16 patients were assigned to the unreachable group and 25 patients to the reachable group. LC, PR, and radius have significantly higher values in unreachable cases than in reachable cases ([Formula: see text], [Formula: see text], [Formula: see text]). The logistic regression analysis showed that LC and PR were significantly associated with reachability ([Formula: see text], [Formula: see text]). The areas under the curve with ROC analysis of the LC and PR index were 0.903 and 0.618. The LC's cut-off value was 578.25. CONCLUSION: We investigated whether the geometrical attributes of the bronchial route to the lesion can predict the difficulty of reaching the lesions in the bronchoscopic biopsy. LC, PR, and radius have significantly higher values in unreachable cases than in reachable cases. LC and PR index can be potentially used to predict the navigational success of the bronchoscope.


Asunto(s)
Broncoscopía , Neoplasias Pulmonares , Humanos , Biopsia , Bronquios/diagnóstico por imagen , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/patología , Tomografía Computarizada por Rayos X
13.
J Robot Surg ; 17(4): 1411-1420, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36689076

RESUMEN

Our objective was to evaluate the feasibility of a multi-section continuum robotic ureteroscope to address the difficulties with access into certain renal calyces during flexible ureteroscopy. First, the robotic ureteroscope developed in previous research, which utilizes three actuated bendable sections controlled by wires, was modified for use in this project. Second, using phantom models created from five randomly selected computer tomography urograms, the flexible ureteroscope and robotic ureteroscope were evaluated, focusing on several factors: time taken to access each renal calyx, time taken to aim at three targets on each renal calyx, the force generated in the renal pelvic wall associated with ureteroscope manipulation, and the distance and standard deviation between the ureteroscope and the target. As a result, the robotic ureteroscope utilized significantly less force during lower pole calyx access (flexible ureteroscope vs. robotic ureteroscope; 2.0 vs. 0.98 N, p = 0.03). When aiming at targets, the standard deviation of proper target access was smaller for each renal calyx (upper pole: 0.49 vs. 0.11 mm, middle: 0.84 vs. 0.12 mm, lower pole: 3.4 vs. 0.19 mm) in the robotic ureteroscope group, and the distance between the center point of the ureteroscope image and the target was significantly smaller in the robotic ureteroscope group (upper: 0.49 vs. 0.19 mm, p < 0.001, middle: 0.77 vs. 0.17 mm, p < 0.001, lower: 0.77 vs. 0.22 mm, p < 0.001). In conclusion, our robotic ureteroscope demonstrated improved maneuverability and facilitated accuracy and precision while reducing the force on the renal pelvic wall during access into each renal calyx.


Asunto(s)
Cálculos Renales , Procedimientos Quirúrgicos Robotizados , Humanos , Ureteroscopios , Cálculos Renales/diagnóstico por imagen , Cálculos Renales/cirugía , Ureteroscopía/métodos , Procedimientos Quirúrgicos Robotizados/métodos , Estudios de Factibilidad , Resultado del Tratamiento , Cálices Renales/diagnóstico por imagen , Cálices Renales/cirugía
14.
Phys Med Biol ; 68(10)2023 05 15.
Artículo en Inglés | MEDLINE | ID: mdl-37080237

RESUMEN

Objective.Clinical outcomes of transperineal prostate interventions, such as biopsy, thermal ablations, and brachytherapy, depend on accurate needle placement for effectiveness. However, the accurate placement of a long needle, typically 150-200 mm in length, is challenging due to needle deviation induced by needle-tissue interaction. While several approaches for needle trajectory correction have been studied, many of them do not translate well to practical applications due to the use of specialized needles not yet approved for clinical use, or to relying on needle-tissue models that need to be tailored to individual patients.Approach.In this paper, we present a robot-assisted collaborative needle insertion method that only requires an actuated passive needle guide and a conventional needle. The method is designed to assist a physician inserting a needle manually through a needle guide. If the needle is deviated from the intended path, actuators shifts the needle radially in order to steer the needle trajectory and compensate for needle deviation adaptively. The needle guide is controlled by a new data-driven algorithm which does not requirea prioriinformation about needle or tissue properties. The method was evaluated in experiments with bothin vitroandex vivophantoms.Main results.The experiments inex vivotissue reported a mean final placement error of 0.36 mm with a reduction of 96.25% of placement error when compared to insertions without the use of assistive correction.Significance.Presented results show that the proposed closed-loop formulation can be successfully used to correct needle deflection during collaborative manual insertion with potential to be easily translated into clinical application.


Asunto(s)
Agujas , Próstata , Masculino , Humanos , Biopsia , Pelvis , Algoritmos
15.
J Magn Reson Imaging ; 36(4): 987-92, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-22645031

RESUMEN

PURPOSE: To develop and evaluate image registration methodology for automated re-identification of tumor-suspicious foci from preprocedural MR exams during MR-guided transperineal prostate core biopsy. MATERIALS AND METHODS: A hierarchical approach for automated registration between planning and intra-procedural T2-weighted prostate MRI was developed and evaluated on the images acquired during 10 consecutive MR-guided biopsies. Registration accuracy was quantified at image-based landmarks and by evaluating spatial overlap for the manually segmented prostate and sub-structures. Registration reliability was evaluated by simulating initial mis-registration and analyzing the convergence behavior. Registration precision was characterized at the planned biopsy targets. RESULTS: The total computation time was compatible with a clinical setting, being at most 2 min. Deformable registration led to a significant improvement in spatial overlap of the prostate and peripheral zone contours compared with both rigid and affine registration. Average in-slice landmark registration error was 1.3 ± 0.5 mm. Experiments simulating initial mis-registration resulted in an estimated average capture range of 6 mm and an average in-slice registration precision of ±0.3 mm. CONCLUSION: Our registration approach requires minimum user interaction and is compatible with the time constraints of our interventional clinical workflow. The initial evaluation shows acceptable accuracy, reliability and consistency of the method.


Asunto(s)
Algoritmos , Interpretación de Imagen Asistida por Computador/métodos , Biopsia Guiada por Imagen/métodos , Imagen por Resonancia Magnética Intervencional/métodos , Reconocimiento de Normas Patrones Automatizadas/métodos , Neoplasias de la Próstata/patología , Técnica de Sustracción , Adulto , Anciano , Humanos , Aumento de la Imagen/métodos , Masculino , Persona de Mediana Edad , Perineo/cirugía , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
16.
Biomed Microdevices ; 14(1): 165-78, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22037673

RESUMEN

Capsule endoscopy is a promising technique for diagnosing diseases in the digestive system. Here we design and characterize a miniature swimming mechanism that uses the magnetic fields of the MRI for both propulsion and wireless powering of the capsule. Our method uses both the static and the radio frequency (RF) magnetic fields inherently available in MRI to generate a propulsive force. Our study focuses on the evaluation of the propulsive force for different swimming tails and experimental estimation of the parameters that influence its magnitude. We have found that an approximately 20 mm long, 5 mm wide swimming tail is capable of producing 0.21 mN propulsive force in water when driven by a 20 Hz signal providing 0.85 mW power and the tail located within the homogeneous field of a 3 T MRI scanner. We also analyze the parallel operation of the swimming mechanism and the scanner imaging. We characterize the size of artifacts caused by the propulsion system. We show that while the magnetic micro swimmer is propelling the capsule endoscope, the operator can locate the capsule on the image of an interventional scene without being obscured by significant artifacts. Although this swimming method does not scale down favorably, the high magnetic field of the MRI allows self propulsion speed on the order of several millimeter per second and can propel an endoscopic capsule in the stomach.


Asunto(s)
Endoscopía Capsular/métodos , Campos Magnéticos , Imagen por Resonancia Magnética/métodos , Técnicas Analíticas Microfluídicas , Artefactos , Humanos , Relación Señal-Ruido
17.
IEEE Trans Biomed Eng ; 69(1): 412-421, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34242160

RESUMEN

OBJECTIVE: The purpose of this article is to report the translational process of an implantable microdevice platform with an emphasis on the technical and engineering adaptations for patient use, regulatory advances, and successful integration into clinical workflow. METHODS: We developed design adaptations for implantation and retrieval, established ongoing monitoring and testing, and facilitated regulatory advances that enabled the administration and examination of a large set of cancer therapies simultaneously in individual patients. RESULTS: Six applications for oncology studies have successfully proceeded to patient trials, with future applications in progress. CONCLUSION: First-in-human translation required engineering design changes to enable implantation and retrieval that fit with existing clinical workflows, a regulatory strategy that enabled both delivery and response measurement of up to 20 agents in a single patient, and establishment of novel testing and quality control processes for a drug/device combination product without clear precedents. SIGNIFICANCE: This manuscript provides a real-world account and roadmap on how to advance from animal proof-of-concept into the clinic, confronting the question of how to use research to benefit patients.


Asunto(s)
Neoplasias , Preparaciones Farmacéuticas , Animales , Sistemas de Liberación de Medicamentos , Humanos , Neoplasias/tratamiento farmacológico , Prótesis e Implantes , Flujo de Trabajo
18.
J Magn Reson Imaging ; 33(4): 968-73, 2011 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-21448965

RESUMEN

PURPOSE: To investigates the impact of nonrigid motion correction on pixel-wise pharmacokinetic analysis of free-breathing DCE-MRI in patients with solitary pulmonary nodules (SPNs). Misalignment of focal lesions due to respiratory motion in free-breathing dynamic contrast-enhanced MRI (DCE-MRI) precludes obtaining reliable time-intensity curves, which are crucial for pharmacokinetic analysis for tissue characterization. MATERIALS AND METHODS: Single-slice 2D DCE-MRI was obtained in 15 patients. Misalignments of SPNs were corrected using nonrigid B-spline image registration. Pixel-wise pharmacokinetic parameters K(trans) , v(e) , and k(ep) were estimated from both original and motion-corrected DCE-MRI by fitting the two-compartment pharmacokinetic model to the time-intensity curve obtained in each pixel. The "goodness-of-fit" was tested with χ(2) -test in pixel-by-pixel basis to evaluate the reliability of the parameters. The percentages of reliable pixels within the SPNs were compared between the original and motion-corrected DCE-MRI. In addition, the parameters obtained from benign and malignant SPNs were compared. RESULTS: The percentage of reliable pixels in the motion-corrected DCE-MRI was significantly larger than the original DCE-MRI (P = 4 × 10(-7) ). Both K(trans) and k(ep) derived from the motion-corrected DCE-MRI showed significant differences between benign and malignant SPNs (P = 0.024, 0.015). CONCLUSION: The study demonstrated the impact of nonrigid motion correction technique on pixel-wise pharmacokinetic analysis of free-breathing DCE-MRI in SPNs.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Pulmón/patología , Imagen por Resonancia Magnética/métodos , Adulto , Anciano , Anciano de 80 o más Años , Gráficos por Computador , Medios de Contraste/farmacología , Diagnóstico por Imagen/métodos , Femenino , Humanos , Cinética , Masculino , Persona de Mediana Edad , Movimiento (Física) , Reproducibilidad de los Resultados , Respiración , Interfaz Usuario-Computador
19.
Stud Health Technol Inform ; 163: 623-9, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-21335868

RESUMEN

This paper presents the design of a magnetic resonance imaging (MRI) compatible needle placement system actuated by piezoelectric actuators for prostate brachytherapy and biopsy. An MRI-compatible modular 3 degree-of-freedom (DOF) needle driver module coupled with a 3-DOF x-y-z stage is proposed as a slave robot to precisely deliver radioactive brachytherapy seeds under interactive MRI guidance. The needle driver module provides for needle cannula rotation, needle insertion and cannula retraction to enable the brachytherapy procedure with the preloaded needles. The device mimics the manual physician gesture by two point grasping (hub and base) and provides direct force measurement of needle insertion force by fiber optic force sensors. The fabricated prototype is presented and an experiment with phantom trials in 3T MRI is analyzed to demonstrate the system compatibility.


Asunto(s)
Braquiterapia/instrumentación , Imagen por Resonancia Magnética/instrumentación , Sistemas Microelectromecánicos/instrumentación , Agujas , Neoplasias de la Próstata/radioterapia , Implantación de Prótesis/instrumentación , Punciones/instrumentación , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Masculino , Neoplasias de la Próstata/patología , Cirugía Asistida por Computador/instrumentación , Interfaz Usuario-Computador
20.
Med Image Anal ; 73: 102164, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34314953

RESUMEN

[Background] Electromagnetically Navigated Bronchoscopy (ENB) is currently the state-of-the art diagnostic and interventional bronchoscopy. CT-to-body divergence is a critical hurdle in ENB, causing navigation error and ultimately limiting the clinical efficacy of diagnosis and treatment. In this study, Visually Navigated Bronchoscopy (VNB) is proposed to address the aforementioned issue of CT-to-body divergence. [Materials and Methods] We extended and validated an unsupervised learning method to generate a depth map directly from bronchoscopic images using a Three Cycle-Consistent Generative Adversarial Network (3cGAN) and registering the depth map to preprocedural CTs. We tested the working hypothesis that the proposed VNB can be integrated to the navigated bronchoscopic system based on 3D Slicer, and accurately register bronchoscopic images to pre-procedural CTs to navigate transbronchial biopsies. The quantitative metrics to asses the hypothesis we set was Absolute Tracking Error (ATE) of the tracking and the Target Registration Error (TRE) of the total navigation system. We validated our method on phantoms produced from the pre-procedural CTs of five patients who underwent ENB and on two ex-vivo pig lung specimens. [Results] The ATE using 3cGAN was 6.2 +/- 2.9 [mm]. The ATE of 3cGAN was statistically significantly lower than that of cGAN, particularly in the trachea and lobar bronchus (p < 0.001). The TRE of the proposed method had a range of 11.7 to 40.5 [mm]. The TRE computed by 3cGAN was statistically significantly smaller than those computed by cGAN in two of the five cases enrolled (p < 0.05). [Conclusion] VNB, using 3cGAN to generate the depth maps was technically and clinically feasible. While the accuracy of tracking by cGAN was acceptable, the TRE warrants further investigation and improvement.


Asunto(s)
Broncoscopía , Neoplasias Pulmonares , Animales , Bronquios , Humanos , Pulmón/diagnóstico por imagen , Neoplasias Pulmonares/diagnóstico por imagen , Fantasmas de Imagen , Porcinos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA