Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Cardiovasc Electrophysiol ; 30(12): 2790-2796, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31646698

RESUMEN

BACKGROUND: We present a new, easily applicable approach for the guidance of cryoballoon (CB) pulmonary vein isolation (PVI) procedures that use the combination of a 3D-mapping system image integration module and computed tomographic (CT)-derived anatomy. The aim of this retrospective, nonrandomized study was to investigate: (a) an alternative use for an established radiofrequency image integration module for cryo procedures; (b) a guidance technology for cryo PVI based on integrated CT anatomy; and (c) its clinical impact. METHODS AND RESULTS: CT left atrium-angiography was performed in 50 consecutive patients before a CB PVI procedure, and a 3D reconstruction of the cardiac anatomy was segmented. A total of 25 patients were treated using conventional fluoroscopy; 25 patients were treated using the 3D image integration technique. In the image integration group, the CARTO3 UNIVU (Biosense Webster) module was used for image integration of 3D anatomy and fluoroscopic imaging. Transseptal puncture and cryo PVI were guided by 3D-overlay imaging. Procedures were feasible without complications in all patients and cryo PVI procedures were successfully guided using the image integration technique. The intraprocedural time needed to perform image integration was 37 ± 10 seconds. Fluoroscopy time was 31.7 ± 11.7 minutes in the conventional group and 20.1 ± 7.9 minutes in the image integration group (P < .001), procedure time was 116.3 ± 29.0 minutes in the conventional group vs 101.2 ± 20.9 minutes in the 3D group (P = .04). CONCLUSION: 3D-overlay guidance of CB PVI is feasible, safe, and applicable in real time with minimal effort. It may significantly reduce radiation exposure by introducing 3D information, known from electroanatomic mapping systems, into cryo PVI procedures.


Asunto(s)
Fibrilación Atrial/cirugía , Criocirugía , Imagenología Tridimensional , Venas Pulmonares/cirugía , Cirugía Asistida por Computador , Tomografía Computarizada por Rayos X , Potenciales de Acción , Anciano , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/fisiopatología , Criocirugía/efectos adversos , Estudios de Factibilidad , Femenino , Frecuencia Cardíaca , Humanos , Imagenología Tridimensional/efectos adversos , Masculino , Persona de Mediana Edad , Modelos Cardiovasculares , Tempo Operativo , Modelación Específica para el Paciente , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/fisiopatología , Estudios Retrospectivos , Cirugía Asistida por Computador/efectos adversos , Factores de Tiempo , Tomografía Computarizada por Rayos X/efectos adversos , Resultado del Tratamiento
2.
J Cardiovasc Electrophysiol ; 30(2): 195-204, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30288836

RESUMEN

BACKGROUND: The relationship between the local electrograms (EGMs) and wall thickness (WT) heterogeneity within infarct scars has not been thoroughly described. The relationship between WT and voltages and substrates for ventricular tachycardia (VT) was examined. METHODS: In 12 consecutive patients with myocardial infarction and VT, WT, defined by a multidetector computed tomography, and voltage were compared. In multicomponent EGMs, amplitudes of both far- and near-field components were manually measured, and the performance of the three-dimensional-mapping system automatic voltage measurement was assessed. RESULTS: Of 15 748 points acquired, 2677 points within 5 mm of the endocardial surface were analyzed. In total, 909 (34.0%) multicomponent EGMs were identified; 785 (86.4%) and 883 (97.1%) were distributed in the WT less than 4 and 5 mm, respectively. Far-field EGM voltages increased linearly from 0.14 mV (0.08-0.28 mV) in the WT: 0 to 1 mm to 0.70 mV (0.43-2.62 mV) in the WT: 4 to 5 mm (ρ = 0.430; P < 0.001), and a significant difference was demonstrated between any two WT-groups (P ≤ 0.001). In contrast, near-field EGM voltages varied from 0.27 mV (0.11-0.44 mV) in the WT: 0 to 1 mm to 0.29 mV (0.17-0.53 mV) in the WT: 4 to 5 mm with a poorer correlation (ρ = 0.062, P = 0.04). The proportion of points where the system automatically measured the voltage on near-field EGMs increased from less than 10% in areas of WT: 4 to 5 mm to 50% in areas less than 2 mm. Of 21 VTs observed, seven hemodynamically stable VTs were mapped and terminated in WT: 1 to 4 mm area. CONCLUSIONS: Although far-field voltages gradually increase with the WT, near-field does not. The three-dimensional-mapping system preferentially annotates the near-field components in thinner areas (center of the scar) and the far-field component in thicker areas when building a voltage map. Critical sites of VT are distributed in WT: 1 to 4 mm areas.


Asunto(s)
Potenciales de Acción , Cicatriz/diagnóstico por imagen , Técnicas Electrofisiológicas Cardíacas , Ventrículos Cardíacos/diagnóstico por imagen , Tomografía Computarizada Multidetector , Infarto del Miocardio/diagnóstico por imagen , Taquicardia Ventricular/diagnóstico , Adulto , Anciano , Anciano de 80 o más Años , Ablación por Catéter , Cicatriz/complicaciones , Cicatriz/fisiopatología , Femenino , Ventrículos Cardíacos/fisiopatología , Ventrículos Cardíacos/cirugía , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/complicaciones , Infarto del Miocardio/fisiopatología , Valor Predictivo de las Pruebas , Medición de Riesgo , Factores de Riesgo , Taquicardia Ventricular/etiología , Taquicardia Ventricular/fisiopatología , Taquicardia Ventricular/cirugía
3.
Europace ; 21(Supplement_1): i27-i33, 2019 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-30801128

RESUMEN

Successful mapping and ablation of ventricular tachycardias remains a challenging clinical task. Whereas conventional entrainment and activation mapping was for many years the gold standard to identify reentrant circuits in ischaemic ventricular tachycardia ablation procedures, substrate mapping has become the cornerstone of ventricular tachycardia ablation. In the last decade, technology has dramatically improved. In parallel to high-density automated mapping, cardiac imaging and image integration tools are increasingly used to assess the structural ventricular tachycardia substrate. The aim of this review is to describe the technologies underlying these new mapping systems and to discuss their possible role in providing new insights into identification and visualization of reentrant tachycardia mechanisms.


Asunto(s)
Técnicas de Imagen Cardíaca , Ablación por Catéter/métodos , Técnicas Electrofisiológicas Cardíacas/métodos , Sistema de Conducción Cardíaco/anatomía & histología , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirugía , Humanos
4.
J Cardiovasc Electrophysiol ; 29(8): 1125-1134, 2018 08.
Artículo en Inglés | MEDLINE | ID: mdl-29858871

RESUMEN

INTRODUCTION: Recognition of implantable cardioverter defibrillator (ICD) lead malfunction before occurrence of life threatening complications is crucial. We aimed to assess the effectiveness of remote monitoring associated or not with a lead noise alert for early detection of ICD lead failure. METHODS: From October 2013 to April 2017, a median of 1,224 (578-1,958) ICD patients were remotely monitored with comprehensive analysis of all transmitted materials. ICD lead failure and subsequent device interventions were prospectively collected in patients with (RMLN) and without (RM) a lead noise alert (Abbott Secure Sense™ or Medtronic Lead Integrity Alert™) in their remote monitoring system. RESULTS: During a follow-up of 4,457 patient years, 64 lead failures were diagnosed. Sixty-one (95%) of the diagnoses were made before any clinical complication occurred. Inappropriate shocks were delivered in only one patient of each group (3%), with an annual rate of 0.04%. All high voltage conductor failures were identified remotely by a dedicated impedance alert in 10 patients. Pace-sense component failures were correctly identified by a dedicated alert in 77% (17 of 22) of the RMLN group versus 25% (8 of 32) of the RM group (P = 0.002). The absence of a lead noise alert was associated with a 16-fold increase in the likelihood of initiating either a shock or ATP (OR: 16.0, 95% CI 1.8-143.3; P = 0.01). CONCLUSION: ICD remote monitoring with systematic review of all transmitted data is associated with a very low rate of inappropriate shocks related to lead failure. Dedicated noise alerts further reduce inappropriate detection of ventricular arrhythmias.


Asunto(s)
Alarmas Clínicas , Desfibriladores Implantables/efectos adversos , Electrodos Implantados/efectos adversos , Análisis de Falla de Equipo/métodos , Falla de Equipo , Tecnología de Sensores Remotos/métodos , Adulto , Anciano , Alarmas Clínicas/tendencias , Desfibriladores Implantables/tendencias , Electrodos Implantados/tendencias , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
5.
J Cardiovasc Electrophysiol ; 29(11): 1570-1575, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30168230

RESUMEN

INTRODUCTION: Radiofrequency (RF) lesion metrics are influenced by underlying parameters like RF power, duration, and contact force (CF), and utilization of lesion metric indices (ablation index [AI]) is a proposed strategy to predict lesion quality. The aim of this study was to analyze the influence of underlying parameters on lesion metrics of high-power short-duration (HPSD) and standard RF applications using an in silico and ex vivo model. METHODS AND RESULTS: An in silico simulation study was designed to simulate HPSD and standard ablations, in which ablation parameters could systematically be varied. For each simulated ablation process (n = 5732), the corresponding AI value was calculated. HPSD and standard RF settings were then applied in a porcine ex vivo model ( n = 120 lesions). The resulting lesion metrics were compared and analyzed regarding underlying parameters. RF applications of 50 W/13 seconds, 60 W/10 seconds, 70 W/7 seconds, and 80 W/6 seconds resulted in lesion volumes not significantly different from standard RF applications (30 W/30 seconds, P > 0.05). HPSD lesion diameters were significantly larger and lesion depths were significantly smaller ( P < 0.01) when compared with standard settings. Prolonging RF duration from 5 to 10 seconds resulted in a +27.5% increase, whereas a prolongation of RF duration from 35 to 40 seconds resulted in a +4.8% increase of AI value only. An increase of CF from 1 to 10 g resulted in a +73.0%, an increase of CF from 20 to 30 g resulted in a +10.1% increase of AI value. CONCLUSION: HPSD RF applications resulted in similar lesion volumes but significantly different lesion geometries when compared with standard setting RF applications.


Asunto(s)
Simulación por Computador , Músculo Esquelético/cirugía , Ablación por Radiofrecuencia/métodos , Animales , Simulación por Computador/normas , Músculo Esquelético/irrigación sanguínea , Músculo Esquelético/fisiología , Ablación por Radiofrecuencia/normas , Porcinos , Factores de Tiempo
6.
Artículo en Inglés | MEDLINE | ID: mdl-29737045

RESUMEN

Pacemaker-induced arrhythmias represent a very rare complication. Algorithm-induced ventricular tachycardias have been described but this report is the first to describe a ventricular fibrillation caused by transient undersensing of the ventricular lead during an abdominal ultrasound.

7.
Heart Rhythm ; 17(1): 66-74, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31295585

RESUMEN

BACKGROUND: Subcutaneous implantable cardioverter-defibrillator (S-ICD) implantations are rapidly expanding. However, the subcutaneous detection and interpretation of cardiac signals in S-ICDs is much more challenging than by conventional devices. There is a complete paradigm shift in cardiac signal sensing with subcutaneous signal detection, leading in some cases to oversensing with restricted programming options. OBJECTIVES: The aim of this single-center study was to quantify and describe cases where recurring oversensing made the extraction of the device necessary. METHODS: Consecutive patients (n = 108) implanted with an S-ICD in our tertiary referral hospital were considered for analysis. Clinical and remote monitoring data were analyzed. RESULTS: The S-ICD had to be explanted in 6 of 108 implanted patients (5.6%) because of refractory oversensing issues: myopotential oversensing, P- or T-wave oversensing, rate-dependent left bundle branch block aberrancy during exercise with R-wave double counting, and R-wave amplitude decrease after ventricular tachycardia ablation leading to noise detection. Seventeen of 108 patients experienced oversensing (15.7%): 9 patients had at least 1 inappropriate charge without a shock (8.3%), 3 patients had at least 1 inappropriate shock (2.8%), and 5 patients had both episodes (4.6%). CONCLUSION: So far, cardiologists have had to deal with transvenous ICD lead fractures, but signal oversensing without correcting programming option could be the equivalent weakness of S-ICDs, despite an adequate screening.


Asunto(s)
Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables/efectos adversos , Remoción de Dispositivos/métodos , Cardioversión Eléctrica/efectos adversos , Fibrilación Ventricular/terapia , Muerte Súbita Cardíaca/etiología , Cardioversión Eléctrica/instrumentación , Electrocardiografía , Falla de Equipo , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Fibrilación Ventricular/fisiopatología
8.
Heart Rhythm ; 16(9): 1341-1347, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31125669

RESUMEN

BACKGROUND: Atrial tachycardias (ATs) are often seen in the context of atrial fibrillation (AF) ablation. OBJECTIVES: To evaluate the role of the Marshall bundle (MB) network in left atrial (LA) ATs using high-density 3-dimensional mapping. METHODS: A total of 199 ATs were mapped in 140 patients (112 male, mean age: 61.8 years); 133 (66.8%) were macroreentrant and 66 (33.2%) were scar-related reentry circuits. MB-dependent ATs were suggested by activation mapping analysis and confirmed with entrainment along the circuit. RESULTS: The MB network participated in 60 (30.2%) reentrant ATs: 31 perimitral ATs (PMATs) and 29 localized reentry circuits. Of 60 MB-related ATs, 49 (81.6%) terminated with radiofrequency (RF) ablation: 44 (73.3%) at the MB-LA junction and 5 (8.3%) at the MB-coronary sinus (CS) junction, while 9 (15%) terminated after 2.5-5 cc of ethanol infusion inside the vein of Marshall (VOM). Of the 31 PMATs, 17 (54.8%) terminated at the MB-LA junction, 5 (16.1%) at the MB-CS junction, and 7 (22.6%) with ethanol infusion. Of the 29 localized reentry circuits using the MB, 27 (93.1%) terminated at the MB-LA junction, none at the MB-CS junction, and 2 (6.9%) after ethanol infusion. Recurrences were mostly observed after RF ablation (18 of 37 patients, 49%) compared to ethanol infusion (1 of 9 patients, 11%) (P = .06). CONCLUSIONS: MB reentrant ATs accounted for up to 30.2% of the left ATs after AF ablation. Ablation of the MB-LA or CS-MB connections or ethanol infusion inside the VOM is required to treat these arrhythmias.


Asunto(s)
Fibrilación Atrial/cirugía , Mapeo del Potencial de Superficie Corporal/métodos , Ablación por Catéter , Sistema de Conducción Cardíaco , Complicaciones Posoperatorias , Taquicardia Supraventricular , Fibrilación Atrial/complicaciones , Fibrilación Atrial/fisiopatología , Electrofisiología Cardíaca/métodos , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Cicatriz/diagnóstico , Cicatriz/etiología , Cicatriz/fisiopatología , Femenino , Atrios Cardíacos/fisiopatología , Sistema de Conducción Cardíaco/patología , Sistema de Conducción Cardíaco/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/fisiopatología , Venas Pulmonares/efectos de los fármacos , Venas Pulmonares/cirugía , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/etiología , Taquicardia Supraventricular/fisiopatología , Resultado del Tratamiento
9.
Circ Arrhythm Electrophysiol ; 12(12): e006857, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31760821

RESUMEN

BACKGROUND: Various strategies for ablation of ventricular tachycardia (VT) have been described, but their impact on ventricular fibrillation (VF) is largely unknown. The aim of our study was to assess the effect of substrate-based VT ablation targeting local abnormal ventricular activity (LAVA) on recurrent VF events in patients with structural heart disease. METHODS: A retrospective 2-center study was performed on patients with structural heart disease and both VT and VF, with incident VT ablation procedures targeting LAVAs. Generalized estimating equations with a Poisson loglinear model were used to assess the impact of catheter ablation on VF episodes. The change in VF events before and after catheter ablation was compared with matched controls without ablation. RESULTS: From a total of 686 patients with an incident VT ablation procedure targeting LAVAs, 21 patients (age, 57±14 years; left ventricular ejection fraction, 30±10%) had both VT and VF and met inclusion criteria. A total of 80 VF events were recorded in the implantable cardioverter-defibrillator logs the 6 months preceding ablation. Complete and partial LAVA elimination was achieved in 11 (52%) and 10 (48%) patients, respectively. Catheter ablation was associated with a highly significant reduction in VF recurrences (P<0.0001), which were limited to 3 (14%) patients at 6 months. The total number of VF events thereby decreased from 80 to 3, from a median of 1.0 (range, 1-29) to 0.0 (range, 0-1) in the 6 months before and after ablation, respectively. The reduction in VF events was significantly greater in patients with catheter ablation compared with 21 matched controls during 6-month periods following and preceding a baseline assessment (Poisson ß-coefficient, 1.39; P=0.0003). CONCLUSIONS: Substrate-guided VT ablation targeting LAVAs may be associated with a significant reduction in recurrent VF, suggesting that VT and VF share overlapping arrhythmogenic substrates in patients with structural heart disease.


Asunto(s)
Ablación por Catéter/efectos adversos , Frecuencia Cardíaca , Taquicardia Ventricular/cirugía , Fibrilación Ventricular/cirugía , Potenciales de Acción , Adulto , Anciano , Femenino , Francia/epidemiología , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Recurrencia , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/epidemiología , Taquicardia Ventricular/fisiopatología , Factores de Tiempo , Resultado del Tratamiento , Fibrilación Ventricular/diagnóstico , Fibrilación Ventricular/epidemiología , Fibrilación Ventricular/fisiopatología
10.
Heart Rhythm ; 16(4): 553-561, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30389441

RESUMEN

BACKGROUND: Ablation of complex atrial tachycardias (ATs) is difficult. OBJECTIVE: The purpose of this study was to elucidate a mechanism underlying the behavior of ATs during ablation and to create an algorithm to predict it. METHODS: An algorithm predicting termination/conversion of AT and the second AT circuit associated with the ablation site was developed from 52 index reentrant AT high-resolution activation maps in 45 patients (retrospective phase). First, the wavefront collision site was identified. Then, the N or N-1 beat was defined for each collision associated with the ablation site. When the AT involved wavefront collision solely between N-1/N-1 (N/N) beats, the AT would terminate during ablation. Conversely, when the AT included wavefront collision between N/N-1 beats, the index AT would convert to a second AT. The algorithm was then prospectively tested in 172 patients with 194 ATs (127 anatomic macroreentrant ATs [AMATs], 44 non-AMATs, 23 multiple-loop ATs). RESULTS: Accuracy in predicting AT termination/conversion and the second AT circuit was 95.9% overall, 96.1% in AMATs, 95.5% in non-AMATs, and 95.7% in multiple-loop ATs. Median (25th-75th percentile) absolute variation between predicted and actually observed cycle length of the second AT was 6 (4-9) ms. Prediction failure occurred in 8 ATs; either the second AT used an unmapped chamber or structure in the index map (n = 7) or a line of block was misinterpreted as very slow conduction in the index map (n = 1). CONCLUSION: A simple mechanism underlies the behavior of ATs during ablation, even in complex ATs. With a simple algorithm using high-resolution mapping, AT termination/conversion and the second AT circuit and cycle length may be predicted from the index activation map.


Asunto(s)
Ablación por Catéter , Sistema de Conducción Cardíaco/fisiopatología , Taquicardia por Reentrada en el Nodo Atrioventricular/fisiopatología , Taquicardia por Reentrada en el Nodo Atrioventricular/cirugía , Algoritmos , Técnicas Electrofisiológicas Cardíacas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Taquicardia por Reentrada en el Nodo Atrioventricular/clasificación
11.
Card Electrophysiol Clin ; 11(3): 459-471, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31400870

RESUMEN

Electrocardiographic imaging is a mapping technique aiming to noninvasively characterize cardiac electrical activity using signals collected from the torso to reconstruct epicardial potentials. Its efficacy has been demonstrated clinically, from mapping premature ventricular complexes and accessory pathways to of complex arrhythmias. Electrocardiographic imaging uses a standardized workflow. Signals should be checked manually to avoid automatic processing errors. Reentry is confirmed in the presence of local activation covering the arrhythmia cycle length. Focal breakthroughs demonstrate a QS pattern associated with centrifugal activation. Electrocardiographic imaging offers a unique opportunity to better understand the mechanism of cardiac arrhythmias and guide ablation.


Asunto(s)
Arritmias Cardíacas , Electrocardiografía , Arritmias Cardíacas/diagnóstico por imagen , Arritmias Cardíacas/fisiopatología , Ablación por Catéter , Técnicas Electrofisiológicas Cardíacas , Humanos
12.
JACC Clin Electrophysiol ; 5(1): 66-77, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30678788

RESUMEN

OBJECTIVES: This study sought to evaluate the relation between bipolar electrode spacing and far- and near-field electrograms. BACKGROUND: The detailed effects of bipolar spacing on electrograms (EGMs) is not well described. METHODS: With a HD-Grid catheter, EGMs from different bipole pairs could be created in each acquisition. This study analyzed the effect of bipolar spacing on EGMs in 7 infarcted sheep. A segment was defined as a 2-mm center-to-center bipole. In total, 4,768 segments (2,020 healthy, 1,542 scar, and 1,206 in border areas, as defined by magnetic resonance imaging [MRI]) were covered with an electrode pair of spacing of 2 mm (Bi-2), 4 mm (Bi-4), and 8 mm (Bi-8). RESULTS: A total of 3,591 segments in Bi-2 were free from local abnormal ventricular activities (LAVAs); 1,630 segments were within the MRI-defined scar and/or border area. Among them, 172 (10.6%) segments in Bi-4 and 219 (13.4%) segments in Bi-8 showed LAVAs. In contrast, LAVAs were identified in 1,177 segments in Bi-2; 1,118 segments were within the MRI-defined scar and/or border area. Among them, LAVAs were missed in 161 (14.4%) segments in Bi-4 and in 409 (36.6%) segments in Bi-8. In segments with LAVAs, median far-field voltage increased from 0.09 mV (25th to 75th percentile: 0.06 to 0.14 mV) in Bi-2, to 0.16 mV (25th to 75th percentile: 0.10 to 0.24 mV) in Bi-4, and to 0.28 mV (25th to 75th percentile: 0.20 to 0.42 mV) in Bi-8 (p < 0.0001). Median near-field voltage increased from 0.14 mV (25th to 75th percentile: 0.08 to 0.25 mV) in Bi-2, to 0.21 mV (25th to 75th percentile: 0.12 to 0.35 mV) in Bi-4, and to 0.32 mV (25th to 75th percentile: 0.17 to 0.48 mV) in Bi-8 (p < 0.0001). The median near-/far-field voltage ratio decreased from 1.67 in Bi-2, to 1.43 in Bi-4, and 1.23 in Bi-8 (p < 0.0001). CONCLUSIONS: Closer spacing better discriminates surviving tissue from dead scar area. Although far-field voltage systematically increases with spacing, near-field voltages were more variable, depending on local surviving muscular bundles. Near-field EGMs are more easily observed with smaller spacing, largely due to the reduction of the far-field effect.


Asunto(s)
Electrocardiografía , Mapeo Epicárdico , Animales , Catéteres Cardíacos , Cicatriz/diagnóstico por imagen , Cicatriz/fisiopatología , Modelos Animales de Enfermedad , Electrocardiografía/instrumentación , Electrocardiografía/métodos , Electrodos , Mapeo Epicárdico/instrumentación , Mapeo Epicárdico/métodos , Diseño de Equipo , Femenino , Corazón/diagnóstico por imagen , Imagen por Resonancia Magnética , Infarto del Miocardio/diagnóstico por imagen , Infarto del Miocardio/fisiopatología , Ovinos
13.
Heart Rhythm ; 15(5): 642-650, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29709229

RESUMEN

BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (S-ICD) remains a new technology requiring accurate assessment of the various aspects of its functioning. Isolated cases of delayed sensing of ventricular arrhythmia have been described. OBJECTIVE: The purpose of this multicenter study was to assess the quality of sensing during induced ventricular fibrillation (VF). METHODS: One hundred thirty-seven patients underwent induction of VF at the end of the S-ICD implantation. RESULTS: VF induction was successful in 133 patients (97%). Mean time to first therapy was 16.2 ± 3.1 seconds, with a substantial range from 12.5 to 27.0 seconds. Four different detection profiles were arbitrarily defined: (1) optimal detection (n = 39 [29%]); (2) undersensing with moderate prolongation of time to therapy (<18 seconds; n = 68 [51%]); (3) undersensing with significant prolongation of the time to therapy (>18 seconds; n = 19 [14%]); and (4) absence of therapy or prolonged time to therapy related to noise oversensing (n = 7 [6%]). In some of the patients in the last group, despite induction of VF the initial counter was never filled, the device did not charge the capacitors, and the shock was not delivered because of a sustained diagnosis of noise (n = 5). A manual shock by the device or an external shock had to be delivered to restore the sinus rhythm. CONCLUSION: Our study demonstrated a marked sensing delay leading to prolonged time to therapy in a large number of S-ICD patients. A few worrisome cases of noise oversensing inhibiting the therapies were detected. These results support the need for systematic intraoperative defibrillation testing.


Asunto(s)
Arritmias Cardíacas/terapia , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Electrocardiografía , Sistema de Conducción Cardíaco/fisiopatología , Arritmias Cardíacas/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados
14.
Front Cardiovasc Med ; 5: 169, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30542653

RESUMEN

An early repolarization pattern can be observed in 1% up to 13% of the overall population. Whereas, this pattern was associated with a benign outcome for many years, several more recent studies demonstrated an association between early repolarization and sudden cardiac death, so-called early repolarization syndrome. In early repolarization syndrome patients, current imbalances between epi- and endo-cardial layers result in dispersion of de- and repolarization. As a consequence, J waves or ST segment elevations can be observed on these patients' surface ECGs as manifestations of those current imbalances. Whereas, an early repolarization pattern is relatively frequently found on surface ECGs in the overall population, the majority of individuals presenting with an early repolarization pattern will remain asymptomatic and the isolated presence of an early repolarization pattern does not require further intervention. The mismatch between frequently found early repolarization patterns in the overall population, low incidences of sudden cardiac deaths related to early repolarization syndrome, but fatal, grave consequences in affected patients remains a clinical challenge. More precise tools for risk stratification and identification of this minority of patients, who will experience events, remain a clinical need. This review summarizes the epidemiologic, pathophysiologic and diagnostic background and presents therapeutic options of early repolarization syndrome.

15.
Front Cardiovasc Med ; 5: 123, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30280100

RESUMEN

Idiopathic ventricular fibrillation (IVF) is the main cause of unexplained sudden cardiac death, particularly in young patients under the age of 35. IVF is a diagnosis of exclusion in patients who have survived a VF episode without any identifiable structural or metabolic causes despite extensive diagnostic testing. Genetic testing allows identification of a likely causative mutation in up to 27% of unexplained sudden deaths in children and young adults. In the majority of cases, VF is triggered by PVCs that originate from the Purkinje network. Ablation of VF triggers in this setting is associated with high rates of acute success and long-term freedom from VF recurrence. Recent studies demonstrate that a significant subset of IVF defined by negative comprehensive investigations, demonstrate in fact subclinical structural alterations. These localized myocardial alterations are identified by high density electrogram mapping, are of small size and are mainly located in the epicardium. As reentrant VF drivers are often colocated with regions of abnormal electrograms, this localized substrate can be shown to be mechanistically linked with VF. Such areas may represent an important target for ablation.

16.
Front Physiol ; 9: 1458, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30459630

RESUMEN

AF is a heterogeneous rhythm disorder that is related to a wide spectrum of etiologies and has broad clinical presentations. Mechanisms underlying AF are complex and remain incompletely understood despite extensive research. They associate interactions between triggers, substrate and modulators including ionic and anatomic remodeling, genetic predisposition and neuro-humoral contributors. The pulmonary veins play a key role in the pathogenesis of AF and their isolation is associated to high rates of AF freedom in patients with paroxysmal AF. However, ablation of persistent AF remains less effective, mainly limited by the difficulty to identify the sources sustaining AF. Many theories were advanced to explain the perpetuation of this form of AF, ranging from a single localized focal and reentrant source to diffuse bi-atrial multiple wavelets. Translating these mechanisms to the clinical practice remains challenging and limited by the spatio-temporal resolution of the mapping techniques. AF is driven by focal or reentrant activities that are initially clustered in a relatively limited atrial surface then disseminate everywhere in both atria. Evidence for structural remodeling, mainly represented by atrial fibrosis suggests that reentrant activities using anatomical substrate are the key mechanism sustaining AF. These reentries can be endocardial, epicardial, and intramural which makes them less accessible for mapping and for ablation. Subsequently, early interventions before irreversible remodeling are of major importance. Circumferential pulmonary vein isolation remains the cornerstone of the treatment of AF, regardless of the AF form and of the AF duration. No ablation strategy consistently demonstrated superiority to pulmonary vein isolation in preventing long term recurrences of atrial arrhythmias. Further research that allows accurate identification of the mechanisms underlying AF and efficient ablation should improve the results of PsAF ablation.

17.
Circ Arrhythm Electrophysiol ; 11(2): e005558, 2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-29438999

RESUMEN

BACKGROUND: Biatrial tachycardia (BiAT) is a rare form of atrial macroreentrant tachycardia, in which both atria form a critical part of the circuit. We aimed to identify the characteristics and precise circuits of single-loop macroreentrant BiATs. METHODS AND RESULTS: We identified 8 patients (median age, 59.5 years old) with 9 BiATs in a cohort of 336 consecutive patients from 2 institutions who had undergone AT catheter ablation using an automatic ultrahigh-resolution mapping system. Seven of the 8 patients had a history of persistent AF ablation, including septal or anterior left atrium ablation before developing BiAT. One of the 8 patients had a history of an atrial septal patch closure with a massively enlarged right atrium. Nine ATs (median cycle length, 334 ms; median 12 561 points in the left atrium; 8814 points in the right atrium) were diagnosed as single-loop macroreentrant BiATs. We observed 3 types of BiAT (1) BiAT with a perimitral and peritricuspid reentrant circuit (n=3), (2) BiAT using the right atrium septum and a perimitral circuit (n=3), and (3) BiAT using only the left atrium and right atrium septum (n=3). Catheter ablation successfully terminated 8 of the 9 BiATs. CONCLUSIONS: All patients who developed BiAT had an electric obstacle on the anteroseptal left atrium, primarily from prior ablation lesions. In this situation, mapping of both atria should be considered during AT. Because 3 types of single-loop BiAT were observed, ablation strategies should be adjusted to the type of BiAT circuit.


Asunto(s)
Mapeo del Potencial de Superficie Corporal/métodos , Ablación por Catéter/métodos , Atrios Cardíacos/fisiopatología , Sistema de Conducción Cardíaco/fisiopatología , Cirugía Asistida por Computador/métodos , Taquicardia por Reentrada en el Nodo Atrioventricular/diagnóstico , Anciano , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Taquicardia por Reentrada en el Nodo Atrioventricular/fisiopatología , Taquicardia por Reentrada en el Nodo Atrioventricular/cirugía , Resultado del Tratamiento
18.
Heart Rhythm ; 15(3): 326-333, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-29081399

RESUMEN

BACKGROUND: Anatomic macroreentrant atrial tachycardias (MATs) are conventionally reported to depend on the cavotricuspid isthmus, the mitral isthmus, or the left atrial roof, and are commonly seen following catheter ablation for atrial fibrillation. OBJECTIVES: To define the precise circuits of anatomic MAT with ultrahigh-resolution mapping. METHODS: In 57 patients (mean age, 62 years; 10 female) who developed ≥1 anatomic MAT, we analyzed 88 MAT circuits including 16 peritricuspid, 42 perimitral, and 30 roof-dependent circuits, using high-density mapping and entrainment. RESULTS: Of 16 peritricuspid atrial tachycardias (ATs), 8 (50.0%) showed a circuit not limited to the tricuspid annulus. However, cavotricuspid isthmus ablation terminated the tachycardia in all patients. Similarly, 26 of 42 perimitral ATs (61.9%) showed a circuit not limited to the mitral annulus, and a low-voltage zone <0.1 mV around the mitral annulus was associated with nontypical perimitral ATs (P < .0001). The practical isthmus was not in the mitral isthmus in 13 of these 26 perimitral ATs (50%). Finally, 22 of 30 roof-dependent ATs (73.3%) had a circuit not rotating around both pairs of pulmonary veins. Brief assessment of the activation direction on the posterior wall in relation to that on the septal, anterior, and lateral wall helped deduce the circuit of roof-dependent AT in 27 of 30 (90.0%). Practical isthmus was not in the roof in 8 of 22 (36.4%). Practical isthmuses mapped with the system were significantly shorter than the usual anatomic isthmuses (16.1 ± 8.2 mm vs 33.7 ± 10.4 mm) (P < .0001). CONCLUSIONS: High-density mapping successfully identified the precise circuits and the practical isthmus of anatomic MATs in patients with prior atrial fibrillation ablation.


Asunto(s)
Fibrilación Atrial/cirugía , Mapeo del Potencial de Superficie Corporal/métodos , Ablación por Catéter/efectos adversos , Aumento de la Imagen/métodos , Complicaciones Posoperatorias , Taquicardia por Reentrada en el Nodo Atrioventricular/diagnóstico , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Taquicardia por Reentrada en el Nodo Atrioventricular/etiología , Taquicardia por Reentrada en el Nodo Atrioventricular/fisiopatología
19.
Circ Arrhythm Electrophysiol ; 11(6): e006019, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29769223

RESUMEN

BACKGROUND: Characteristics of multiple-loop atrial tachycardia (AT) circuits have never precisely examined. METHODS: In 193 consecutive post-atrial fibrillation ablation patients with AT, 44 multiple-loop ATs including 42 dual-loop AT and 2 triple-loop AT in 41 (21.2%) were diagnosed with the high-resolution mapping system and analyzed off-line. RESULTS: In dual-loop ATs, 3 types were identified: type M, a combination of 2 anatomic macroreentrant ATs (AMATs) in 19 (43.2%); type MN, with 1 AMAT and 1 non-AMAT in 12 (27.3%); and type N with 2 non-AMATs in 11 (25.0%). The remaining 2 triple-loop ATs (4.5%) were a combination of perimitral-, roof-dependent-, and non-AMAT. At least 1 AMAT was included in 33 (75.0%), and 1 non-AMAT in 25 (56.8%). Of the ATs with at least 1 non-AMAT circuit, a pulmonary vein formed part of the circuit in 16/25 (64.0%). The length of the common isthmus was 3.6±1.4 cm in type M, 1.6±0.7 cm in type MN, and 1.1±0.7 cm in type N (P<0.0001). The area of the common isthmus was 12.92±7.68, 2.46±1.53, and 0.90±0.81 cm2, in Type M, MN, and N (P<0.0001). The narrowest width of the common isthmus was 1.8±0.7 cm, 1.1±0.3 cm, and 0.7±0.3 cm in type M, MN, and N (P<0.0001), respectively. The electrograms in the common isthmus showed longer duration and lower voltage in type N, type MN, and type M (duration: 106±25 ms, 87±27 ms, and 69±27 ms; P=0.006; and voltage: 0.06±0.02 mV, 0.22±0.21 mV, and 0.57±0.50 mV; P<0.0001), respectively. CONCLUSIONS: Multiple-loop ATs are complex, frequently including anatomic circuits. They have specific characteristics determined by the combination of AMAT and non-AMAT.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Venas Pulmonares/cirugía , Taquicardia Supraventricular/etiología , Potenciales de Acción , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Electrocardiografía , Técnicas Electrofisiológicas Cardíacas , Femenino , Francia , Frecuencia Cardíaca , Humanos , Japón , Masculino , Persona de Mediana Edad , Venas Pulmonares/fisiopatología , Factores de Riesgo , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/fisiopatología , Factores de Tiempo , Resultado del Tratamiento
20.
Heart Rhythm ; 15(12): 1853-1861, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30026016

RESUMEN

BACKGROUND: The direct effect of bipolar orientation on electrograms (EGMs) remains unknown. OBJECTIVE: The purpose of this study was to examine the variation of EGMs with diagonally orthogonal bipoles. METHODS: The HD-32 Grid catheter (Abbott, Minneapolis, MN) can assess the effect of bipolar orientation while keeping the interelectrode distance and center unchanged. Seven sheep with anterior myocardial infarction were analyzed using diagonally orthogonal electrode pairs across splines by comparing local EGMs from each pair of opposing electrodes {eg. A1-B3 (southeast direction [SE]) vs A3-B1 (northeast direction [NE])}. RESULTS: A total of 4084 EGMs (1 in each direction) were analyzed for 2042 sites (544 in the infarcted area, 488 in the border area, and 1010 in the normal area). The higher and lower voltages measured using each pair of opposing electrodes significantly differed (1.10 mV [0.43-2.56 mV] vs 0.69 mV [0.28-1.58 mV]; P < .0001), and the median variation was 0.28 mV (0.11-0.80 mV) (31.7% [16.0%-48.9%]). The voltage variation was maximized to 48.7% (37.7%-61.6%) (P < .0001) on sites where the activation wavefront was perpendicular to the one bipolar direction and parallel to the other. A total of 594 of 719 (82.6%) sites with the voltage <0.5 mV and 539 of 699 (77.1%) sites with the voltage >1.5 mV in NE stayed in the same voltage range as those in SE. However, only 348 of 624 (55.8%) sites with the voltage 0.5-1.5 mV in NE stayed in the same range as those in SE. Local ventricular abnormal activities (LAVAs) were detected in 592 of 2042 (29.0%) sites in total, frequently distributed in the border area. A total of 177 (29.9%) LAVAs were missed in one direction and 180 (30.4%) in the other. When 415 (70.1%) LAVAs detected in NE are defined as the reference, 235 of 415 (56.6%) matched with those detected in SE. CONCLUSION: The bipolar voltage and distribution of LAVAs may differ significantly between diagonally orthogonal bipolar pairs at any given site.


Asunto(s)
Mapeo del Potencial de Superficie Corporal/instrumentación , Terapia de Resincronización Cardíaca/métodos , Electrodos , Sistema de Conducción Cardíaco/fisiopatología , Frecuencia Cardíaca/fisiología , Taquicardia Ventricular/diagnóstico , Animales , Modelos Animales de Enfermedad , Diseño de Equipo , Femenino , Imagenología Tridimensional , Ovinos , Taquicardia Ventricular/fisiopatología , Taquicardia Ventricular/terapia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA