Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 131
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
Hum Brain Mapp ; 45(6): e26686, 2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38647048

RESUMEN

Deuterium metabolic imaging (DMI) is an emerging magnetic resonance technique, for non-invasive mapping of human brain glucose metabolism following oral or intravenous administration of deuterium-labeled glucose. Regional differences in glucose metabolism can be observed in various brain pathologies, such as Alzheimer's disease, cancer, epilepsy or schizophrenia, but the achievable spatial resolution of conventional phase-encoded DMI methods is limited due to prolonged acquisition times rendering submilliliter isotropic spatial resolution for dynamic whole brain DMI not feasible. The purpose of this study was to implement non-Cartesian spatial-spectral sampling schemes for whole-brain 2H FID-MR Spectroscopic Imaging to assess time-resolved metabolic maps with sufficient spatial resolution to reliably detect metabolic differences between healthy gray and white matter regions. Results were compared with lower-resolution DMI maps, conventionally acquired within the same session. Six healthy volunteers (4 m/2 f) were scanned for ~90 min after administration of 0.8 g/kg oral [6,6']-2H glucose. Time-resolved whole brain 2H FID-DMI maps of glucose (Glc) and glutamate + glutamine (Glx) were acquired with 0.75 and 2 mL isotropic spatial resolution using density-weighted concentric ring trajectory (CRT) and conventional phase encoding (PE) readout, respectively, at 7 T. To minimize the effect of decreased signal-to-noise ratios associated with smaller voxels, low-rank denoising of the spatiotemporal data was performed during reconstruction. Sixty-three minutes after oral tracer uptake three-dimensional (3D) CRT-DMI maps featured 19% higher (p = .006) deuterium-labeled Glc concentrations in GM (1.98 ± 0.43 mM) compared with WM (1.66 ± 0.36 mM) dominated regions, across all volunteers. Similarly, 48% higher (p = .01) 2H-Glx concentrations were observed in GM (2.21 ± 0.44 mM) compared with WM (1.49 ± 0.20 mM). Low-resolution PE-DMI maps acquired 70 min after tracer uptake featured smaller regional differences between GM- and WM-dominated areas for 2H-Glc concentrations with 2.00 ± 0.35 mM and 1.71 ± 0.31 mM, respectively (+16%; p = .045), while no regional differences were observed for 2H-Glx concentrations. In this study, we successfully implemented 3D FID-MRSI with fast CRT encoding for dynamic whole-brain DMI at 7 T with 2.5-fold increased spatial resolution compared with conventional whole-brain phase encoded (PE) DMI to visualize regional metabolic differences. The faster metabolic activity represented by 48% higher Glx concentrations was observed in GM- compared with WM-dominated regions, which could not be reproduced using whole-brain DMI with the low spatial resolution protocol. Improved assessment of regional pathologic alterations using a fully non-invasive imaging method is of high clinical relevance and could push DMI one step toward clinical applications.


Asunto(s)
Encéfalo , Deuterio , Glucosa , Humanos , Glucosa/metabolismo , Adulto , Masculino , Femenino , Encéfalo/diagnóstico por imagen , Encéfalo/metabolismo , Imagen por Resonancia Magnética/métodos , Adulto Joven , Espectroscopía de Resonancia Magnética/métodos , Sustancia Gris/diagnóstico por imagen , Sustancia Gris/metabolismo , Sustancia Blanca/diagnóstico por imagen , Sustancia Blanca/metabolismo
2.
J Magn Reson Imaging ; 2024 May 09.
Artículo en Inglés | MEDLINE | ID: mdl-38721871

RESUMEN

BACKGROUND: One of the main features of several metabolic disorders is dysregulation of hepatic glucose and lipid metabolism. Deuterium metabolic imaging (DMI) allows for assessing the uptake and breakdown of 2H-labeled substrates, giving specific insight into nutrient processing in healthy and diseased organs. Thus, DMI could be a useful approach for analyzing the differences in liver metabolism of healthy and diseased subjects to gain a deeper understanding of the alterations related to metabolic disorders. PURPOSE: Evaluating the feasibility of DMI as a tool for the assessment of metabolic differences in rodents with healthy and fatty livers (FLs). STUDY TYPE: Animal Model. POPULATION: 18 male Sprague Dawley rats on standard (SD, n = 9, healthy) and high-fat diet (HFD, n = 9, FL disease). FIELD STRENGTH/SEQUENCE: Phase-encoded 1D pulse-acquire sequence and anatomy co-registered phase-encoded 3D pulse-acquire chemical shift imaging for 2H at 9.4T. ASSESSMENT: Localized and nonlocalized liver spectroscopy was applied at eight time points over 104 minutes post injection. The obtained spectra were preprocessed and quantified using jMRUI (v7.0) and the resulting amplitudes translated to absolute concentration (mM) according to the 2H natural abundance water peak. STATISTICAL TESTS: Two-way repeated measures ANOVA were employed to assess between-group differences, with statistical significance at P < 0.05. RESULTS: DMI measurements demonstrated no significant difference (P = 0.98) in the uptake of [6,6'-2H2]glucose between healthy and impaired animals (AUCSD = 1966.0 ± 151.5 mM - minutes vs. AUCHFD = 2027.0 ± 167.6 mM·minutes). In the diseased group, the intrahepatic uptake of palmitic acid d-31 was higher (AUCHFD = 57.4 ± 17.0 mM·minutes, AUCSD = 33.3 ± 10.5 mM·minutes), but without statistical significance owing to substantial in-group variation (P = 0.73). DATA CONCLUSION: DMI revealed higher concentrations of palmitic acid in rats with FL disease and no difference in hepatic glucose concentration between healthy and impaired animals. Thus, DMI appears to be a useful tool for evaluating metabolism in rodents with FL disease. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY: Stage 3.

3.
Neuroimage ; 277: 120250, 2023 08 15.
Artículo en Inglés | MEDLINE | ID: mdl-37414233

RESUMEN

INTRODUCTION: Deuterium metabolic imaging (DMI) and quantitative exchange label turnover (QELT) are novel MR spectroscopy techniques for non-invasive imaging of human brain glucose and neurotransmitter metabolism with high clinical potential. Following oral or intravenous administration of non-ionizing [6,6'-2H2]-glucose, its uptake and synthesis of downstream metabolites can be mapped via direct or indirect detection of deuterium resonances using 2H MRSI (DMI) and 1H MRSI (QELT), respectively. The purpose of this study was to compare the dynamics of spatially resolved brain glucose metabolism, i.e., estimated concentration enrichment of deuterium labeled Glx (glutamate+glutamine) and Glc (glucose) acquired repeatedly in the same cohort of subjects using DMI at 7T and QELT at clinical 3T. METHODS: Five volunteers (4 m/1f) were scanned in repeated sessions for 60 min after overnight fasting and 0.8 g/kg oral [6,6'-2H2]-glucose administration using time-resolved 3D 2H FID-MRSI with elliptical phase encoding at 7T and 3D 1H FID-MRSI with a non-Cartesian concentric ring trajectory readout at clinical 3T. RESULTS: One hour after oral tracer administration regionally averaged deuterium labeled Glx4 concentrations and the dynamics were not significantly different over all participants between 7T 2H DMI and 3T 1H QELT data for GM (1.29±0.15 vs. 1.38±0.26 mM, p=0.65 & 21±3 vs. 26±3 µM/min, p=0.22) and WM (1.10±0.13 vs. 0.91±0.24 mM, p=0.34 & 19±2 vs. 17±3 µM/min, p=0.48). Also, the observed time constants of dynamic Glc6 data in GM (24±14 vs. 19±7 min, p=0.65) and WM (28±19 vs. 18±9 min, p=0.43) dominated regions showed no significant differences. Between individual 2H and 1H data points a weak to moderate negative correlation was observed for Glx4 concentrations in GM (r=-0.52, p<0.001), and WM (r=-0.3, p<0.001) dominated regions, while a strong negative correlation was observed for Glc6 data GM (r=-0.61, p<0.001) and WM (r=-0.70, p<0.001). CONCLUSION: This study demonstrates that indirect detection of deuterium labeled compounds using 1H QELT MRSI at widely available clinical 3T without additional hardware is able to reproduce absolute concentration estimates of downstream glucose metabolites and the dynamics of glucose uptake compared to 2H DMI data acquired at 7T. This suggests significant potential for widespread application in clinical settings especially in environments with limited access to ultra-high field scanners and dedicated RF hardware.


Asunto(s)
Encéfalo , Imagen por Resonancia Magnética , Humanos , Imagen por Resonancia Magnética/métodos , Deuterio/metabolismo , Reproducibilidad de los Resultados , Encéfalo/diagnóstico por imagen , Encéfalo/metabolismo , Glucosa/metabolismo
4.
Am J Physiol Endocrinol Metab ; 324(4): E339-E346, 2023 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-36791322

RESUMEN

Many cells adapt to hyperosmolal conditions by upregulation of organic osmolytes to maintain cell function and integrity. Glycerophosphocholine (GPC), a recognized osmolyte in renal medullary cells, is the major phosphodiester (PDE) in human skeletal muscle, wherefore we hypothesized muscular GPC to be associated with surrogate parameters of fluid status and osmolality in healthy humans. The objective of this study was to investigate the relationship of muscular GPC with surrogate parameters of body fluid status and osmolality. We analyzed data of 30 healthy volunteers who underwent noninvasive 31P-magnetic resonance spectroscopy of either calf (n = 17) or thigh (n = 13) muscle. Therefore, we conducted correlation analyses between phosphor metabolites, and blood values depicting body fluid status and osmolality. Relevant parameters were further implemented in a multivariable regression model to evaluate if GPC concentrations can depict variations in fluid and electrolyte balance. Uric acid (0.437, P = 0.018) and urea (0.387, P = 0.035) were significantly correlated with GPC, which in case of uric acid was independent of sex. Considering sex, following multivariable regression reported GPC as suitable parameter to predict uric acid (R2 = 0.462, adjusted R2 = 0.421; P < 0.001). Our data indicate a connection between muscular GPC concentrations and uric acid, which is a marker of body fluid status, in healthy human subjects, suggesting that skeletal muscle might regulate GPC content in adaptation to changes in fluid status.NEW & NOTEWORTHY Using in vivo magnetic resonance spectroscopy, our study is the first one indicating fluid balance-dependent properties of glycerophosphocholine concentrations in human skeletal muscle. In vivo examination of GPC as organic osmolyte in human skeletal muscle marks a novel approach, which might give further insight on how water and electrolyte balance affect muscle tissue. Beside this main finding, glycerophosphocholine of both calf and thigh muscle correlated remarkably with blood laboratory parameters of lipid metabolism in our study population.


Asunto(s)
Glicerilfosforilcolina , Ácido Úrico , Humanos , Ácido Úrico/metabolismo , Glicerilfosforilcolina/metabolismo , Equilibrio Hidroelectrolítico/fisiología , Espectroscopía de Resonancia Magnética , Músculo Esquelético/diagnóstico por imagen , Músculo Esquelético/metabolismo
5.
Magn Reson Med ; 87(3): 1174-1183, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34719061

RESUMEN

PURPOSE: Lactate is a key metabolite in skeletal muscle and whole-body physiology. Its MR visibility in muscle is affected by overlapping lipid signals and fiber orientation. Double-quantum filtered (DQF) 1 H MRS selectively detects lactate at 1.3 ppm, but at ultra-high field the efficiency of slice-selective 3D-localization with conventional RF pulses is limited by bandwidth. This novel 3D-localized 1 H DQF MRS sequence uses adiabatic refocusing pulses to unambiguously detect lactate in skeletal muscle at 7 T. METHODS: Lactate double-quantum coherences were 3D-localized using slice-selective Shinnar-Le Roux optimized excitation and adiabatic refocusing pulses (similar to semi-LASER). DQF MR spectra were acquired at 7 T from lactate phantoms, meat specimens with injected lactate (exploring multiple TEs and fiber orientations), and human gastrocnemius in vivo during and after exercise (without cuff ischemia). RESULTS: Lactate was readily detected, achieving the full potential of 50% signal with a DQF, in solution. The effects of fiber orientation and TE on the lactate doublet (peak splitting, amplitude, and phase) were in good agreement with theory and literature. Exercise-induced lactate accumulation was detected with 30 s time resolution. CONCLUSION: This novel 3D-localized 1 H DQF MRS sequence can dynamically detect glycolytically generated lactate in muscle during exercise and recovery at 7 T.


Asunto(s)
Ácido Láctico , Músculo Esquelético , Ejercicio Físico , Humanos , Espectroscopía de Resonancia Magnética , Músculo Esquelético/diagnóstico por imagen , Fantasmas de Imagen
6.
J Magn Reson Imaging ; 55(2): 530-540, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34219305

RESUMEN

BACKGROUND: Biliary phosphatidylcholine (PtdC) concentration plays a role in the pathogenesis of bile duct diseases. In vivo phosphorus-31 magnetic resonance spectroscopy (31 P-MRS) at 7 T offers the possibility to assess this concentration noninvasively with high spectral resolution and signal intensity. PURPOSE: Comparison of PtdC levels of cholangiopathic patient groups to a control group using a measured T1 relaxation time of PtdC in healthy subjects. STUDY TYPE: Case control. SUBJECTS: Two patient groups with primary sclerosing cholangitis (PSC, 2f/3 m; age: 43 ± 7 years) and primary biliary cholangitis (PBC, 4f/2 m; age: 57 ± 6 years), and a healthy control group (CON, 2f/3 m; age: 38 ± 7 years). Ten healthy subjects for the assessment of the T1 relaxation time of PtdC. FIELD STRENGTH/SEQUENCE: A 3D phase-encoded pulse-acquire 31 P-MRSI sequence for PtdC quantification and a 1D image-selected in vivo 31 P spectroscopy for T1 estimation at 7 T, and a T2-weighted half-Fourier single-shot turbo spin echo MRI sequence for volumetry at 3 T. ASSESSMENT: Calculation of gallbladder volumes and PtdC concentration in groups using hepatic gamma-adenosine triphosphate signal as an internal reference and correction for insufficient relaxation of PtdC with a T1 value assessed in healthy subjects. STATISTICAL TESTS: Group comparison of PtdC content and gallbladder volumes of the PSC/PBC and CON group using Student's t-tests with a significance level of 5%. RESULTS: PtdC T1 value of 357 ± 85 msec in the gallbladder. Significant lower PtdC content for the PSC group, and for the female subgroup of the PBC group compared to the CON group (PSC/CON: 5.74 ± 0.73 mM vs. 9.64 ± 0.97 mM, PBC(f)/CON: 5.77 ± 1.44 mM vs. 9.64 ± 0.97 mM). Significant higher gallbladder volumes of the patient groups compared to the CON group (PSC/CON: 66.3 ± 15.8 mL vs. 20.9 ± 2.2 mL, PBC/CON: 49.8 ± 18.2 mL vs. 20.9 ± 2.2 mL). DATA CONCLUSION: This study demonstrated the application of a 31 P-MRSI protocol for the quantification of PtdC in the human gallbladder at 7 T. Observed differences in PtdC concentration suggest that this metabolite could serve as a biomarker for specific hepatobiliary disorders. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY STAGE: 3.


Asunto(s)
Colangitis Esclerosante , Vesícula Biliar , Adulto , Femenino , Humanos , Imagen por Resonancia Magnética , Espectroscopía de Resonancia Magnética , Persona de Mediana Edad , Fosfatidilcolinas , Fósforo , Proyectos Piloto
7.
Eur Radiol ; 32(5): 3388-3397, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-34940906

RESUMEN

OBJECTIVES: T2 mapping of the liver is a potential diagnostic tool, but conventional techniques are difficult to perform in clinical practice due to long scan time. We aimed to evaluate the accuracy of a prototype radial turbo-spin-echo (rTSE) sequence, optimized for multi-slice T2 mapping in the abdomen during one breath-hold at 3 T. METHODS: A multi-sample (fat: 0-35%) agarose phantom doped with MnCl2 and 80 subjects (73 patients undergoing abdomen MR examination and 7 healthy volunteers) were investigated. A radial turbo-spin-echo (rTSE) sequence with and without fat suppression, a Cartesian turbo-spin-echo (Cart-TSE) sequence, and a single-voxel multi-echo STEAM spectroscopy (HISTO) were performed in phantom, and fat-suppressed rTSE and HISTO sequences were performed in in vivo measurements. Two approaches were used to sample T2 values: manually selected circular ROIs and whole liver analysis with Gaussian mixture models (GMM). RESULTS: The rTSE-T2s values exhibited a strong correlation with Cart-TSE-T2s (R2 = 0.988) and with HISTO-T2s of water (R2 = 0.972) in phantom with an offset between rTSE and Cart-TSE maps (mean difference = 3.17 ± 1.18 ms). The application of fat suppression decreased T2 values, and the effect was directly proportional to the amount of fat. Measurements in patients yielded a linear relationship between rTSE- and HISTO-T2s (R2 = 0.546 and R2 = 0.580 for ROI and GMM, respectively). CONCLUSION: The fat-suppressed rTSE sequence allows for fast and accurate determination of T2 values of the liver, and appears to be suitable for further large cohort studies. KEY POINTS: •Radial turbo-spin-echo T2 mapping performs comparably to Cartesian TSE-T2 mapping, but an offset in values is observed in phantom measurements. •Fat-suppressed radial turbo-spin-echo T2 mapping is consistent with T2 of water as assessed by MRS in phantom measurements. •Fat-suppressed radial turbo-spin-echo sequence allows fast T2 mapping of the liver in a single breath-hold and is correlated with MRS-based T2 of water.


Asunto(s)
Contencion de la Respiración , Imagen por Resonancia Magnética , Abdomen , Humanos , Hígado/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Agua
8.
Gerontology ; 68(2): 151-161, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-33971654

RESUMEN

BACKGROUND/AIMS: Walking speed (WS) is an objective measure of physical capacity and a modifiable risk factor of morbidity and mortality in the elderly. In this study, we (i) determined effects of 3-month supervised aerobic-strength training on WS, muscle strength, and habitual physical activity; (ii) evaluated capacity of long-term (21 months) training to sustain higher WS; and (iii) identified determinants of WS in the elderly. METHODS: Volunteers (F 48/M 14, 68.4 ± 7.1 years) completed either 3-month aerobic-strength (3 × 1 h/week, n = 48) or stretching (active control, n = 14) intervention (study A). Thirty-one individuals (F 24/M 7) from study A continued in supervised aerobic-strength training (2 × 1 h/week, 21 months) and 6 (F 5/M 1) became nonexercising controls. RESULTS: Three-month aerobic-strength training increased preferred and maximal WS (10-m walk test, p < 0.01), muscle strength (p < 0.01) and torque (p < 0.01) at knee extension, and 24-h habitual physical activity (p < 0.001), while stretching increased only preferred WS (p < 0.03). Effect of training on maximal WS was most prominent in individuals with baseline WS between 1.85 and 2.30 m·s-1. Maximal WS measured before intervention correlated negatively with age (r = -0.339, p = 0.007), but this correlation was weakened by the intervention (r = -0.238, p = 0.06). WS progressively increased within the first 9 months of aerobic-strength training (p < 0.001) and remained elevated during 21-month intervention (p < 0.01). Cerebellar gray matter volume (MRI) was positively associated with maximal (r = 0.54; p < 0.0001) but not preferred WS and explained >26% of its variability, while age had only minor effect. CONCLUSIONS: Supervised aerobic-strength training increased WS, strength, and dynamics of voluntary knee extension as well as habitual physical activity in older individuals. Favorable changes in WS were sustainable over the 21-month period by a lower dose of aerobic-strength training. Training effects on WS were not limited by age, and cerebellar cortex volume was the key determinant of WS.


Asunto(s)
Entrenamiento de Fuerza , Anciano , Ejercicio Físico/fisiología , Humanos , Fuerza Muscular , Torque , Caminata/fisiología , Velocidad al Caminar
9.
BMC Musculoskelet Disord ; 23(1): 925, 2022 Oct 20.
Artículo en Inglés | MEDLINE | ID: mdl-36266679

RESUMEN

OBJECTIVES: To determine the relaxation times of the sodium nucleus, and to investigate the repeatability of quantitative, in vivo TSC measurements using sodium magnetic resonance imaging (23Na-MRI) in human skeletal muscle and explore the discriminatory value of the method by comparing TSCs between healthy subjects and patients with Addison's disease. MATERIALS AND METHODS: In this prospective study, ten healthy subjects and five patients with Addison's disease were involved. 23Na-MRI data sets were acquired using a density-adapted, three-dimensional radial projection reconstruction pulse sequence (DA-3DPR) with a modification for the relaxation times measurements. Differences in TSC between muscle groups and between healthy participants were analysed using a nonparametric Friedman ANOVA test. An interclass correlation coefficient (ICC) was used as the repeatability index. Wilcoxon rank sum test was used for evaluation of differences in TSC between study participants. RESULTS: The mean T1 in the gastrocnemius medialis (GM), the tibialis anterior (TA), and the soleus (S) was 25.9 ± 2.0 ms, 27.6 ± 2.0 ms, and 28.2 ± 2.0 ms, respectively. The mean short component of T2*, T2*short were GM: 3.6 ± 2.0 ms; TA: 3.2 ± 0.5 ms; and S: 3.0 ± 1.0 ms, and the mean long component of T2*, T2*long, were GM: 12.9 ± 0.9 ms; TA: 12.8 ± 0.7 ms; and S: 12.9 ± 2.0 ms, respectively. In healthy volunteers, TSC values in the GM were 19.9 ±0.1  mmol/L, 13.8 ±0.2 mmol/L in TA, and 12.6 ± 0.2 mmol/L in S, and were significantly different (p = 0.0005). The ICCs for GM, TA and S were 0.784, 0.818, 0.807, respectively. In patients with Addison's disease, TSC in GC, TA, and S were 10.2 ± 1.0 mmol/L, 8.4 ± 0.6 mmol/L, and 7.2 ± 0.1 mmol/L, respectively. CONCLUSIONS: TSC quantification in a healthy subject's calf at 7.0 T is reliable; the technique is able to distinguish sodium level differences between muscles and between healthy subjects and Addison's disease patients.


Asunto(s)
Enfermedad de Addison , Sodio , Humanos , Imagen por Resonancia Magnética/métodos , Músculo Esquelético/diagnóstico por imagen , Estudios Prospectivos , Sodio/análisis
10.
Magn Reson Med ; 85(3): 1379-1396, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-32981114

RESUMEN

PURPOSE: To develop a fat-water imaging method that allows reliable separation of the two tissues, uses established robust reconstruction methods, and requires only one single-echo acquisition. THEORY AND METHODS: The proposed method uses spectrally selective dual-band excitation in combination with CAIPIRINHA to generate separate images of fat and water simultaneously. Spatially selective excitation without cross-contamination is made possible by the use of spatial-spectral pulses. Fat and water images can either be visualized separately, or the fat images can be corrected for chemical shift displacement and, in gradient echo imaging, for chemical shift-related phase discrepancy, and recombined with water images, generating fat-water images free of chemical shift effects. Gradient echo and turbo spin echo sequences were developed based on this Simultaneous Multiple Resonance Frequency imaging (SMURF) approach and their performance was assessed at 3Tesla in imaging of the knee, breasts, and abdomen. RESULTS: The proposed method generated well-separated fat and water images with minimal unaliasing artefacts or cross-excitation, evidenced by the near absence of water signal attributed to the fat image and vice versa. The separation achieved was similar to or better than that using separate acquisitions with water- and fat-saturation or Dixon methods. The recombined fat-water images provided similar image contrast to conventional images, but the chemical shift effects were eliminated. CONCLUSION: Simultaneous Multiple Resonance Frequency imaging is a robust fat-water imaging technique that offers a solution to imaging of body regions with significant amounts of fat.


Asunto(s)
Diagnóstico por Imagen , Agua , Tejido Adiposo/diagnóstico por imagen , Artefactos , Pruebas Diagnósticas de Rutina , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Vibración
11.
NMR Biomed ; 34(5): e4266, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-32022964

RESUMEN

1 H-MR spectroscopy of skeletal muscle provides insight into metabolism that is not available noninvasively by other methods. The recommendations given in this article are intended to guide those who have basic experience in general MRS to the special application of 1 H-MRS in skeletal muscle. The highly organized structure of skeletal muscle leads to effects that change spectral features far beyond simple peak heights, depending on the type and orientation of the muscle. Specific recommendations are given for the acquisition of three particular metabolites (intramyocellular lipids, carnosine and acetylcarnitine) and for preconditioning of experiments and instructions to study volunteers.


Asunto(s)
Consenso , Músculo Esquelético/diagnóstico por imagen , Espectroscopía de Protones por Resonancia Magnética , Testimonio de Experto , Humanos , Redes y Vías Metabólicas , Metaboloma , Músculo Esquelético/anatomía & histología , Músculo Esquelético/metabolismo
12.
NMR Biomed ; 34(5): e4484, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33559967

RESUMEN

The translation of MRS to clinical practice has been impeded by the lack of technical standardization. There are multiple methods of acquisition, post-processing, and analysis whose details greatly impact the interpretation of the results. These details are often not fully reported, making it difficult to assess MRS studies on a standardized basis. This hampers the reviewing of manuscripts, limits the reproducibility of study results, and complicates meta-analysis of the literature. In this paper a consensus group of MRS experts provides minimum guidelines for the reporting of MRS methods and results, including the standardized description of MRS hardware, data acquisition, analysis, and quality assessment. This consensus statement describes each of these requirements in detail and includes a checklist to assist authors and journal reviewers and to provide a practical way for journal editors to ensure that MRS studies are reported in full.


Asunto(s)
Consenso , Espectroscopía de Resonancia Magnética , Informe de Investigación/normas , Testimonio de Experto , Humanos , Programas Informáticos
13.
J Magn Reson Imaging ; 53(1): 98-107, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-32501627

RESUMEN

BACKGROUND: Previous in vivo proton MR spectroscopy (MRS) studies have demonstrated the possibility of quantifying amide groups of conjugated bile acids (NHCBA), olefinic lipids and cholesterol (OLC), choline-containing phospholipids (CCPLs), taurine and glycine conjugated bile acids (TCBA, GCBA), methylene group of lipids (ML), and methyl groups of bile acids, lipids, and cholesterol (BALC1.0, BALC0.9, and TBAC) in the gallbladder, which may be useful for the study of cholestatic diseases and cholangiopathies. However, these studies were performed at 1.5T and 3T, and higher magnetic fields may offer improved spectral resolution and signal intensity. PURPOSE: To develop a method for gallbladder MRS at 7T. STUDY TYPE: Retrospective, technical development. POPULATION: Ten healthy subjects (five males and five females), two patients with primary biliary cholangitis (PBC) (one male and one female), and one patient with primary sclerosing cholangitis (PSC) (female). FIELD STRENGTH/SEQUENCE: Free-breathing single-voxel MRS with a modified stimulated echo acquisition mode (STEAM) sequence at 7T. ASSESSMENT: Postprocessing was based on the T2 relaxation of water in the gallbladder and in the liver. Concentrations of biliary components were calculated using water signal. All data were corrected for T2 relaxation times measured in healthy subjects. STATISTICAL TESTS: The range of T2 relaxation time and concentration per bile component, and the resulting mean and standard deviation, were calculated. RESULTS: The concentrations of gallbladder components in healthy subjects were: NHCBA: 93 ± 66 mM, OLC: 154 ± 124 mM, CCPL: 42 ± 17 mM, TCBA: 48 ± 35 mM, GCBA: 67 ± 32 mM, ML: 740 ± 391 mM, BALC1.0: 175 ± 92 mM, BALC0.9: 260 ± 138 mM, and TBAC: 153 ± 90 mM. Mean concentrations of all bile components were found to be lower in patients. DATA CONCLUSION: This work provides a protocol for designing future MRS investigations of the bile system in vivo. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY STAGE: 1.


Asunto(s)
Bilis , Vesícula Biliar , Bilis/diagnóstico por imagen , Femenino , Vesícula Biliar/diagnóstico por imagen , Humanos , Espectroscopía de Resonancia Magnética , Masculino , Espectroscopía de Protones por Resonancia Magnética , Estudios Retrospectivos
14.
Diabetes Obes Metab ; 23(5): 1129-1139, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33464703

RESUMEN

AIMS: To investigate the potential synergistic effects of combined exenatide (EXE) and dapagliflozin (DAPA) versus (PLAC) placebo and DAPA on hepatocellular lipid (HCL) reduction after 24 weeks of treatment. MATERIALS AND METHODS: Thirty patients with type 2 diabetes were randomized to weekly EXE and daily DAPA (n = 16) or weekly PLAC and daily DAPA (n = 14). Inclusion criteria were glycated haemoglobin (HbA1c) 48 to 97 mmol/mol (6.5-11%), age 18 to 75 years, body mass index (BMI) ≥25 kg/m2 and metformin ≥1000 mg. The primary endpoint, HCL levels, were measured at baseline and after 24 weeks of treatment using magnetic resonance spectroscopy. Between-group effects were analysed using general linear models, adjusted for baseline outcome variables, age, sex and BMI. Within-group differences were assessed using a paired t-test. RESULTS: After 24 weeks, HCLs were reduced in both treatment groups (absolute change from baseline: EXE + DAPA -4.4%, 95% confidence interval [CI] -8.2, -0.7, P < 0.05; PLAC + DAPA -3.9%, 95% CI -6.0, -1.7, P < 0.01; relative change: EXE + DAPA -35.6%, PLAC + DAPA -32.3%) with no difference between groups. Similar findings were observed for subcutaneous adipose tissue (SAT) and visceral adipose tissue (VAT). HbA1c (EXE + DAPA -17.8 mmol/mol, [95% CI -24.8, -10.8], P <0.001; PLAC + DAPA -6.9 mmol/mol, [95% CI -10.5, -3.3], P = 0.001) and fasting glucose significantly decreased in both groups, although EXE + DAPA achieved better glycaemic control than PLAC + DAPA (adjusted difference: HbA1c -6.0 mmol/mol [95% CI -9.7, -2.2], P < 0.01). Body weight was reduced in both treatment groups (EXE + DAPA -7.3 kg, 95% CI -9.9, -4.8, P <0.001; PLAC + DAPA -4.6 kg, 95% CI -7.4, -1.8, P <0.01) with comparable results between groups. Changes in HCLs and weight, hip and waist circumference, VAT and SAT were positively associated. CONCLUSION: After 24 weeks, HCLs were significantly but comparably reduced in the EXE + DAPA and PLAC + DAPA groups, despite significantly better glycaemic control in the combined group EXE + DAPA. Changes in HCLs were associated with weight loss and reduction of visceral adiposity, but not with glucose control. Further studies are necessary to evaluate possible additional long-term effects of a combined treatment.


Asunto(s)
Carcinoma Hepatocelular , Diabetes Mellitus Tipo 2 , Neoplasias Hepáticas , Metformina , Adolescente , Adulto , Anciano , Compuestos de Bencidrilo , Glucemia , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Método Doble Ciego , Quimioterapia Combinada , Exenatida/uso terapéutico , Glucósidos , Hemoglobina Glucada , Control Glucémico , Humanos , Hipoglucemiantes/uso terapéutico , Lípidos , Metformina/uso terapéutico , Persona de Mediana Edad , Proyectos Piloto , Estudios Prospectivos , Resultado del Tratamiento , Adulto Joven
15.
J Cardiovasc Magn Reson ; 23(1): 24, 2021 03 15.
Artículo en Inglés | MEDLINE | ID: mdl-33715632

RESUMEN

BACKGROUND: Temporary epicardial pacing wires, implemented in patients during heart transplantation, are routinely removed before discharge. However, in some cases, these wires may remain in situ and are often considered as a contraindication for cardiovascular magnetic resonance (CMR) imaging in the future. Therefore, we aimed to provide data about safety and image quality of CMR in these patients. METHODS: This is a report on a subpopulation out of 88 patients after heart transplantation that were included in a prospective cohort study and underwent multiple CMR in their post-transplant course. During CMR, patients were monitored by electrocardiogram and all examinations were observed by a physician to document potential adverse events. Additionally, image quality was assessed by an imaging specialist. RESULTS: Nineteen of 88 patients included had temporary pacing wires in situ. These patients underwent a total of 51 CMR studies. No major adverse event and only one single, mild sensory event could be documented. All CMR studies showed preserved diagnostic image quality. Temporary pacing wires were visible in 100% of HASTE and cine sequences. In less than 50% of the examinations, temporary pacing wires were also visible in T1 and T2 mapping, short tau inversion recovery (STIR), and late gadolinium enhancement (LGE) sequences, without any impairment of image quality. CONCLUSIONS: With a low event rate of only one mild adverse event during 51 CMR examinations (2%), CMR appears to be safe in patients with retained temporary epicardial pacing wires after heart transplantation. Moreover, image quality was not impaired by the presence of pacing wires.


Asunto(s)
Estimulación Cardíaca Artificial , Trasplante de Corazón , Imagen por Resonancia Magnética , Marcapaso Artificial , Adulto , Anciano , Estimulación Cardíaca Artificial/efectos adversos , Electrocardiografía , Femenino , Trasplante de Corazón/efectos adversos , Humanos , Imagen por Resonancia Magnética/efectos adversos , Masculino , Persona de Mediana Edad , Marcapaso Artificial/efectos adversos , Valor Predictivo de las Pruebas , Estudios Prospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
16.
Molecules ; 26(24)2021 Dec 14.
Artículo en Inglés | MEDLINE | ID: mdl-34946652

RESUMEN

Most in vivo 31P MR studies are realized on 3T MR systems that provide sufficient signal intensity for prominent phosphorus metabolites. The identification of these metabolites in the in vivo spectra is performed by comparing their chemical shifts with the chemical shifts measured in vitro on high-field NMR spectrometers. To approach in vivo conditions at 3T, a set of phantoms with defined metabolite solutions were measured in a 3T whole-body MR system at 7.0 and 7.5 pH, at 37 °C. A free induction decay (FID) sequence with and without 1H decoupling was used. Chemical shifts were obtained of phosphoenolpyruvate (PEP), phosphatidylcholine (PtdC), phosphocholine (PC), phosphoethanolamine (PE), glycerophosphocholine (GPC), glycerophosphoetanolamine (GPE), uridine diphosphoglucose (UDPG), glucose-6-phosphate (G6P), glucose-1-phosphate (G1P), 2,3-diphosphoglycerate (2,3-DPG), nicotinamide adenine dinucleotide (NADH and NAD+), phosphocreatine (PCr), adenosine triphosphate (ATP), adenosine diphosphate (ADP), and inorganic phosphate (Pi). The measured chemical shifts were used to construct a basis set of 31P MR spectra for the evaluation of 31P in vivo spectra of muscle and the liver using LCModel software (linear combination model). Prior knowledge was successfully employed in the analysis of previously acquired in vivo data.


Asunto(s)
Hígado/metabolismo , Músculo Esquelético/metabolismo , Resonancia Magnética Nuclear Biomolecular , Fósforo/metabolismo , Programas Informáticos , Adenosina Difosfato/metabolismo , Adenosina Trifosfato/metabolismo , Humanos , Fosfatos/metabolismo , Fosfatidilcolinas/metabolismo , Fosfatidiletanolaminas/metabolismo , Proyectos Piloto
17.
NMR Biomed ; : e4347, 2020 Aug 17.
Artículo en Inglés | MEDLINE | ID: mdl-32808407

RESUMEN

With a 40-year history of use for in vivo studies, the terminology used to describe the methodology and results of magnetic resonance spectroscopy (MRS) has grown substantially and is not consistent in many aspects. Given the platform offered by this special issue on advanced MRS methodology, the authors decided to describe many of the implicated terms, to pinpoint differences in their meanings and to suggest specific uses or definitions. This work covers terms used to describe all aspects of MRS, starting from the description of the MR signal and its theoretical basis to acquisition methods, processing and to quantification procedures, as well as terms involved in describing results, for example, those used with regard to aspects of quality, reproducibility or indications of error. The descriptions of the meanings of such terms emerge from the descriptions of the basic concepts involved in MRS methods and examinations. This paper also includes specific suggestions for future use of terms where multiple conventions have emerged or coexisted in the past.

18.
MAGMA ; 33(4): 455-468, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-31980962

RESUMEN

OBJECTIVES: Chemical Shift Encoded Magnetic Resonance Imaging (CSE-MRI)-based quantification of low-level (< 5% of proton density fat fraction-PDFF) fat infiltration requires highly accurate data reconstruction for the assessment of hepatic or pancreatic fat accumulation in diagnostics and biomedical research. MATERIALS AND METHODS: We compare three software tools available for water/fat image reconstruction and PDFF quantification with MRS as the reference method. Based on the algorithm exploited in the tested software, the accuracy of fat fraction quantification varies. We evaluate them in phantom and in vivo MRS and MRI measurements. RESULTS: The signal model of Intralipid 20% emulsion used for phantoms was established for 3 T and 9.4 T fields. In all cases, we noticed a high coefficient of determination (R-squared) between MRS and MRI-PDFF measurements: in phantoms <0.9924-0.9990>; and in vivo <0.8069-0.9552>. Bland-Altman analysis was applied to phantom and in vivo measurements. DISCUSSION: Multi-echo MRI in combination with an advanced algorithm including multi-peak spectrum modeling appears as a valuable and accurate method for low-level PDFF quantification over large FOV in high resolution, and is much faster than MRS methods. The graph-cut algorithm (GC) showed the fewest water/fat swaps in the PDFF maps, and hence stands out as the most robust method of those tested.


Asunto(s)
Tejido Adiposo/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Espectroscopía de Resonancia Magnética/métodos , Adulto , Algoritmos , Emulsiones , Femenino , Humanos , Hígado/diagnóstico por imagen , Masculino , Fantasmas de Imagen , Programas Informáticos , Agua
20.
J Magn Reson Imaging ; 49(2): 597-607, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30291654

RESUMEN

BACKGROUND: Hepatic disorders are often associated with changes in the concentration of phosphorus-31 (31 P) metabolites. Absolute quantification offers a way to assess those metabolites directly but introduces obstacles, especially at higher field strengths (B0 ≥ 7T). PURPOSE: To introduce a feasible method for in vivo absolute quantification of hepatic 31 P metabolites and assess its clinical value by probing differences related to volunteers' age and body mass index (BMI). STUDY TYPE: Prospective cohort. SUBJECTS/PHANTOMS: Four healthy volunteers included in the reproducibility study and 19 healthy subjects arranged into three subgroups according to BMI and age. Phantoms containing 31 P solution for correction and validation. FIELD STRENGTH/SEQUENCE: Phase-encoded 3D pulse-acquire chemical shift imaging for 31 P and single-volume 1 H spectroscopy to assess the hepatocellular lipid content at 7T. ASSESSMENT: A phantom replacement method was used. Spectra located in the liver with sufficient signal-to-noise ratio and no contamination from muscle tissue, were used to calculate following metabolite concentrations: adenosine triphosphates (γ- and α-ATP); glycerophosphocholine (GPC); glycerophosphoethanolamine (GPE); inorganic phosphate (Pi ); phosphocholine (PC); phosphoethanolamine (PE); uridine diphosphate-glucose (UDPG); nicotinamide adenine dinucleotide-phosphate (NADH); and phosphatidylcholine (PtdC). Correction for hepatic lipid volume fraction (HLVF) was performed. STATISTICAL TESTS: Differences assessed by analysis of variance with Bonferroni correction for multiple comparison and with a Student's t-test when appropriate. RESULTS: The concentrations for the young lean group corrected for HLVF were 2.56 ± 0.10 mM for γ-ATP (mean ± standard deviation), α-ATP: 2.42 ± 0.15 mM, GPC: 3.31 ± 0.27 mM, GPE: 3.38 ± 0.87 mM, Pi : 1.42 ± 0.20 mM, PC: 1.47 ± 0.24 mM, PE: 1.61 ± 0.20 mM, UDPG: 0.74 ± 0.17 mM, NADH: 1.21 ± 0.38 mM, and PtdC: 0.43 ± 0.10 mM. Differences found in ATP levels between lean and overweight volunteers vanished after HLVF correction. DATA CONCLUSION: Exploiting the excellent spectral resolution at 7T and using the phantom replacement method, we were able to quantify up to 10 31 P-containing hepatic metabolites. The combination of 31 P magnetic resonance spectroscopy imaging data acquisition and HLVF correction was not able to show a possible dependence of 31 P metabolite concentrations on BMI or age, in the small healthy population used in this study. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2019;49:597-607.


Asunto(s)
Índice de Masa Corporal , Hígado/diagnóstico por imagen , Hígado/metabolismo , Imagen por Resonancia Magnética/métodos , Fósforo/análisis , Adulto , Factores de Edad , Anciano , Calibración , Femenino , Voluntarios Sanos , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Hepatopatías/metabolismo , Espectroscopía de Resonancia Magnética , Masculino , Persona de Mediana Edad , Fantasmas de Imagen , Estudios Prospectivos , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA