Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 66
Filtrar
Más filtros

País/Región como asunto
País de afiliación
Intervalo de año de publicación
1.
Clin Infect Dis ; 70(4): 583-594, 2020 02 03.
Artículo en Inglés | MEDLINE | ID: mdl-30949690

RESUMEN

BACKGROUND: 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG-PET/CT) has emerged as a useful diagnostic tool for suspected infective endocarditis (IE) in patients with prosthetic valves or implantable devices. However, there is limited evidence regarding use of 18F-FDG-PET/CT for the diagnosis of native valve endocarditis (NVE). METHODS: Between 2014 and 2017, 303 episodes of left-sided suspected IE (188 prosthetic valves/ascending aortic prosthesis and 115 native valves) were studied. 18F-FDG-PET/CT accuracy was determined in the subgroups of patients with NVE and prosthetic valve endocarditis (PVE)/ascending aortic prosthesis infection (AAPI). Associations between inflammatory infiltrate patterns and 18F-FDG-PET/CT uptake were investigated in an exploratory ad hoc histological analysis. RESULTS: Among 188 patients with PVE/AAPI, the sensitivity, specificity, and positive and negative predictive values of 18F-FDG-PET/CT focal uptake were 93%, 90%, 89%, and 94%, respectively, while among 115 patients with NVE, the corresponding values were 22%, 100%, 100%, and 66%. The inclusion of abnormal 18F-FDG cardiac uptake as a major criterion at admission enabled a recategorization of 76% (47/62) of PVE/AAPI cases initially classified as "possible" to "definite" IE. In the histopathological analysis, a predominance of polymorphonuclear cell inflammatory infiltrate and a reduced extent of fibrosis were observed in the PVE group only. CONCLUSIONS: Use of 18F-FDG-PET/CT at the initial presentation of patients with suspected PVE increases the diagnostic capability of the modified Duke criteria. In patients who present with suspected NVE, the use of 18F-FDG-PET/CT is less accurate and could only be considered a complementary diagnostic tool for a specific population of patients with NVE.


Asunto(s)
Endocarditis Bacteriana , Endocarditis , Prótesis Valvulares Cardíacas , Infecciones Relacionadas con Prótesis , Endocarditis/diagnóstico por imagen , Endocarditis Bacteriana/diagnóstico por imagen , Fluorodesoxiglucosa F18 , Prótesis Valvulares Cardíacas/efectos adversos , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones , Infecciones Relacionadas con Prótesis/diagnóstico por imagen , Radiofármacos
2.
Eur Radiol ; 28(6): 2665-2674, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29352381

RESUMEN

OBJECTIVES: Despite advances in non-invasive myocardial perfusion imaging (MPI) evaluation, computed tomography (CT) multiphase MPI protocols have not yet been compared with the highly accurate rubidium-82 positron emission tomography (82RbPET) MPI. Thus, this study aimed to evaluate agreement between 82RbPET and 320-detector row CT (320-CT) MPI using a multiphase protocol in suspected CAD patients. METHODS: Forty-four patients referred for MPI evaluation were prospectively enrolled and underwent dipyridamole stress 82RbPET and multiphase 320-CT MPI (five consecutive volumetric acquisitions during stress). Statistical analyses were performed using the R software. RESULTS: There was high agreement for recognizing summed stress scores ≥ 4 (kappa 0.77, 95% CI 0.55-0.98, p < 0.001) and moderate for detecting SDS ≥ 2 (kappa 0.51, 95% CI 0.23-0.80, p < 0.001). In a per segment analysis, agreement was high for the presence of perfusion defects during stress and rest (kappa 0.75 and 0.82, respectively) and was moderate for impairment severity (kappa 0.58 and 0.65, respectively). The 320-CT protocol was safe, with low radiation burden (9.3 ± 2.4 mSv). CONCLUSIONS: There was a significant agreement between dipyridamole stress 320-CT MPI and 82RbPET MPI in the evaluation of suspected CAD patients of intermediate risk. The multiphase 320-CT MPI protocol was feasible, diagnostic and with relatively low radiation exposure. KEY POINTS: • Rubidium-82 PET and 320-MDCT can perform MPI studies for CAD investigation. • There is high agreement between rubidium-82 PET and 320-MDCT for MPI assessment. • Multiphase CT perfusion protocols are feasible and with low radiation. • Multiphase CT perfusion protocols can identify image artefacts.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Radiofármacos , Radioisótopos de Rubidio , Angiografía por Tomografía Computarizada , Vasos Coronarios/diagnóstico por imagen , Dipiridamol/farmacología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tomografía Computarizada Multidetector , Imagen de Perfusión Miocárdica/métodos , Tomografía de Emisión de Positrones/métodos , Estudios Prospectivos , Programas Informáticos , Tomografía Computarizada de Emisión de Fotón Único/métodos , Vasodilatadores/farmacología
3.
Eur J Nucl Med Mol Imaging ; 44(5): 876-885, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-27987028

RESUMEN

PURPOSE: Myocardial perfusion imaging (MPI) with 99mTc-sestamibi (sestamibi) SPECT and rubidium-82 (82Rb) PET both allow for combined assessment of perfusion and left ventricular (LV) function. We sought to compare parameters of LV function obtained with both methods using a single dipyridamole stress dose. MATERIALS AND METHODS: A group of 221 consecutive patients (65.2 ± 10.4 years, 52.9% male) underwent consecutive sestamibi and 82Rb MPI after a single dipyridamole stress dose. Sestamibi and 82Rb summed rest (SRS), stress (SSS) and difference (SDS) scores, and LV end-diastolic (EDV) and end-systolic (ESV) volumes and left ventricular ejection fraction (LVEF) were compared. RESULTS: Bland-Altman analysis showed that with increasing ESV and EDV the difference between the two perfusion tracers increased both at rest and post-stress. The mean difference in EDV and ESV between the two perfusion tracers at rest could both be independently explained by the 82Rb SDS and the sestamibi SRS. The combined models explained approximately 30% of the variation in these volumes between the two perfusion tracers (R2 = 0.261, p = 0.005; R2 = 0.296, p < 0.001, for EDV and ESV respectively). However, the mean difference in LVEF between sestamibi and 82Rb showed no significant trend post-stress (R2 = 0.001, p = 0.70) and only a modest linear increase with increasing LVEF values at rest (R2 = 0.032, p = 0.009). CONCLUSIONS: Differences in left ventricular volumes between sestamibi and 82Rb MPI increase with increasing volumes. However, these differences did only marginally affect LVEF between sestamibi and 82Rb. In clinical practice these results should be taken into account when comparing functional derived parameters between sestamibi and 82Rb MPI.


Asunto(s)
Tomografía Computarizada por Emisión de Fotón Único Sincronizada Cardíaca , Dipiridamol/farmacología , Imagen de Perfusión Miocárdica , Tomografía de Emisión de Positrones , Radioisótopos de Rubidio , Tecnecio Tc 99m Sestamibi , Función Ventricular Izquierda/efectos de los fármacos , Anciano , Electrocardiografía , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Estrés Fisiológico/efectos de los fármacos , Función Ventricular Izquierda/fisiología
4.
Hematol Transfus Cell Ther ; 40(3): 245-249, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30128433

RESUMEN

OBJECTIVE: To investigate, in a large prospective multicenter study, whether 2-[18F]-fluoro-2-deoxy-d-glucose-positron emission tomography is sufficiently accurate to identify clinically important bone marrow involvement by Hodgkin's lymphoma to replace routine bone marrow biopsy in a developing tropical country. METHODS: Patients newly diagnosed with Hodgkin's lymphoma were recruited from six cancer centers in Brazil. All were staged by the results of positron emission tomography/computed tomography that were centrally reviewed and by iliac crest bone marrow biopsy. Patients were classified as having marrow disease if they had lymphoma identified by marrow biopsy histology or had focal 2-[18F]-fluoro-2-deoxy-d-glucose marrow uptake that resolved following chemotherapy. RESULTS: A total of 246 participants were recruited from six different centers and 62 (25.2%) were judged to have Hodgkin's lymphoma in the bone marrow. Positron emission tomography and biopsies were concordant in 206 patients (83%). Positron emission tomography correctly identified marrow disease in 59/62 patients (95.1%) and marrow biopsy in 25/62 patients (40.3%). In 22/62 (35.4%) patients, the two techniques were concordant in the diagnosis of marrow involvement. Of the forty discordant results, positron emission tomography found bone marrow involvement in 37 patients, upstaging 22 to stage IV and having an impact on therapeutic decision in nine cases given their reallocation from early to advanced stage. Three false negative positron emission tomography results were obtained with bone marrow biopsy giving positive findings. All three cases were classified as stage IV regardless of bone marrow findings implying no modification in the clinical management. The sensitivity, specificity and accuracy of positron emission tomography for detecting bone marrow disease were 95%, 100% and 98% and for bone marrow biopsy they were 40%, 100% and 84%, respectively. CONCLUSION: We conclude that positron emission tomography can replace marrow biopsy in Brazilian patients with Hodgkin's lymphoma without compromising clinical management.

5.
J Clin Endocrinol Metab ; 92(11): 4485-8, 2007 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-17684046

RESUMEN

OBJECTIVE: The objective of the study was to determine the diagnostic accuracy of (18)F-fluorodeoxyglucose ((18)F-FDG) positron emission tomography (PET) in the preoperative diagnosis of thyroid nodules with indeterminate fine-needle aspiration biopsy results. METHODS: Forty-two consecutive patients with thyroid nodules with indeterminate cytological results participated in this study. Abnormal (18)F-FDG PET uptake was assessed visually and by measuring the maximum standardized uptake value (SUVmax) in thyroid topography. All these results were compared with the final pathological results. RESULTS: The presence of focal uptake correlated with a greater risk of malignancy (P = 0.018). All 11 malignant nodules had focal uptake (sensitivity of 100%). Of the 31 patients with benign nodules, there were 19 with positive uptake (specificity of 38.7%). The pre-PET probability of cancer was 26.2% (11 of 42), and this probability increased to 36.7% after PET for those patients whose exam showed focal uptake (11 of 30). The preoperative use of (18)F-FDG PET would result in a significant reduction (39%, 12 of 31) in the number of thyroidectomies performed in patients with benign lesions. SUVmax could not improve this degree of accuracy. There was no correlation between thyroid nodule size and SUVmax value (P = 0.96). Patients with carcinomas were younger than patients with benign lesions (P = 0.048). There was no other clinical, laboratory, or ultrasonographic variable related to malignancy. CONCLUSIONS: (18)F-FDG PET provides high sensitivity to malignant lesions and may be a potentially useful tool in the evaluation of thyroid nodules with indeterminate cytological findings. For these nodules the number of unnecessary thyroidectomies in a hypothetical algorithm using (18)F-FDG PET would be reduced by 39%.


Asunto(s)
Fluorodesoxiglucosa F18 , Radiofármacos , Nódulo Tiroideo/diagnóstico por imagen , Nódulo Tiroideo/cirugía , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Biopsia con Aguja Fina , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tomografía de Emisión de Positrones , Pronóstico , Neoplasias de la Tiroides/diagnóstico por imagen , Neoplasias de la Tiroides/patología , Neoplasias de la Tiroides/cirugía , Nódulo Tiroideo/patología , Tiroidectomía
6.
J Nucl Cardiol ; 14(6): 852-9, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-18022112

RESUMEN

BACKGROUND: Imaging with (123)I-metaiodobenzylguanidine (MIBG) is used for the assessment of cardiac sympathetic activity (CSA). We analyzed CSA before and after cardiac resynchronization therapy (CRT), and correlated these data with CRT response. METHODS AND RESULTS: Thirty patients with chronic heart failure and classic indications for CRT were prospectively studied before and at least 3 months after CRT. The variables analyzed were: QRS width, left-ventricular ejection fraction (LVEF), left-ventricular end-diastolic diameter (LVEDD), heart/mediastinum MIBG uptake ratio (H/M), and washout rate (WR). After CRT, patients were divided into two groups: group 1 (21 patients), responders improving to functional class (FC) I or II; and group 2 (9 patients), nonresponders remaining in FC III or IV. After CRT, only group 1 showed favorable changes in QRS width (P =.003), LVEF (P =.01), LVEDD (P =.04), and H/M ratio (P =.003). The H/M ratio and WR were associated with CRT response (P =.005 and P =.04, respectively). The H/M ratio was the only independent predictor of CRT response (P =.01). Receiver operating characteristic curves showed that the optimal H/M ratio cutoff point was 1.36 (sensitivity, 75%; specificity, 71%). CONCLUSIONS: Improvement in CSA correlated with a positive CRT response. Lower MIBG uptake before therapy was associated with CRT nonresponse. The H/M ratio could be helpful in selecting patients for CRT.


Asunto(s)
3-Yodobencilguanidina , Enfermedades del Sistema Nervioso Autónomo/diagnóstico por imagen , Enfermedades del Sistema Nervioso Autónomo/terapia , Gasto Cardíaco Bajo/diagnóstico por imagen , Gasto Cardíaco Bajo/prevención & control , Estimulación Cardíaca Artificial/métodos , Sistema Nervioso Simpático/fisiopatología , Adulto , Enfermedades del Sistema Nervioso Autónomo/complicaciones , Gasto Cardíaco Bajo/etiología , Femenino , Humanos , Masculino , Pronóstico , Cintigrafía , Radiofármacos , Resultado del Tratamiento
7.
Clinics (Sao Paulo) ; 62(2): 121-6, 2007 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-17505695

RESUMEN

OBJECTIVE: The metabolic test using 18F-fluorodeoxyglucose is a useful tool for the management of patients with Hodgkin lymphoma, either for staging purposes or for the evaluation of suspicious masses that can frequently occur after treatment. The aim of the present study was to investigate the value of the 18F-fluorodeoxyglucose test performed with a dual-head coincident gamma camera (CGC-PET with fluorodeoxyglucose) for the staging and the detection of residual tumor of patients with Hodgkin lymphoma. METHODS: Thirty-eight consecutive patients were included in this retrospective study; the metabolic test comprising CGC-PET with FDG was done in 18 patients for staging work-up (Group 1), and the results were compared to conventional clinical staging procedures that included computed tomography scans and bone marrow biopsy. The remaining 20 patients were evaluated with CGC-PET with fluorodeoxyglucose due to the presence of residual masses or a new lesion (Group 2). RESULTS: The 18F-Fluorodeoxyglucose metabolic test, CGC-PET with fluorodeoxyglucose, upstaged 5 (27%) of the Group 1 patients and detected more lesions (45) than conventional methods of staging (33). Of the 20 patients in Group 2, 11 had positive18F-fluorodeoxyglucosetests, and a viable tumor was confirmed in 9 patients. Regarding the 9 patients with negative fluorodeoxyglucose metabolic tests, the 1-year probability of recurrence was 11.8%. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of the CGC-PET with fluorodeoxyglucose test were 90%, 80%, 82%, 89%, and 85% respectively. CONCLUSIONS: The metabolic test comprising CGC-PET with fluorodeoxyglucose had a higher diagnostic accuracy than conventional methods in the staging of Hodgkin lymphoma and thus is a valuable noninvasive tool for the diagnosis of suspicious lesions.


Asunto(s)
Fluorodesoxiglucosa F18 , Enfermedad de Hodgkin/diagnóstico por imagen , Radiofármacos , Adolescente , Adulto , Femenino , Fluorodesoxiglucosa F18/metabolismo , Estudios de Seguimiento , Enfermedad de Hodgkin/patología , Humanos , Masculino , Persona de Mediana Edad , Estadificación de Neoplasias , Neoplasia Residual , Radiofármacos/metabolismo , Estudios Retrospectivos , Sensibilidad y Especificidad , Tomografía Computarizada de Emisión
8.
Int J Cardiol ; 106(1): 29-34, 2006 Jan 04.
Artículo en Inglés | MEDLINE | ID: mdl-16321662

RESUMEN

BACKGROUND: beta-adrenergic receptor antagonism with drugs like carvedilol slows the progression of heart failure by an undefined mechanism. (123)I-metaiodobenzylguanidine (MIBG) is an analog of norepinephrine used to study cardiac sympathetic function. METHODS AND RESULTS: In this double-blind randomized, placebo-controlled study, we used MIBG imaging to evaluate the effect of carvedilol (n=15) or placebo (n=7) on neuronal norepinephrine reuptake in patients with heart failure due to idiopathic dilated cardiomyopathy, with LVEF less than 35% and functional class II or III. The drug was begun at 6.25 mg b.i.d. and titrated up to 25 mg t.i.d, as tolerated. Thorax planar scintigraphy images were obtained 15 min (Initial) and 4 h (Late) after MIBG injection at baseline (t(0)) as well as 2 months (t(1)) and 6 months (t(2)) after drug initiation. The multifarious statistical technique of profile analysis was applied and p< or =0.05 was considered significant. The heart/mediastinum MIBG uptake (H/M ratio) was calculated from these images. On the Initial images, the H/M ratio was 1.64+/-0.24 (t(0)), 1.71+/-0.21 (t(1)), and 1.87+/-0.34 (t(2)) in the carvedilol group and 1.68+/-0.42 (t(0)), 1.81+/-0.45 (t(1)), and 1.69+/-0.44 (t(2)) in controls (p=0.0455). On the Late images, the H/M ratio was 1.39+/-0.24 (t(0)), 1.53+/-0.23 (t(1)), and 1.64+/-0.36 (t(2)) in the carvedilol group, and 1.49+/-0.45 (t(0)), 1.53+/-0.47 (t(1)), and 1.47+/-0.41 (t(2)) in controls (p=0.0513). CONCLUSION: Compared with placebo, the addition of carvedilol to existing heart failure treatment incites the reverse remodeling of cardiac sympathetic nervous system function.


Asunto(s)
Antagonistas Adrenérgicos beta/uso terapéutico , Carbazoles/uso terapéutico , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/tratamiento farmacológico , Propanolaminas/uso terapéutico , Sistema Nervioso Simpático/diagnóstico por imagen , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/tratamiento farmacológico , 3-Yodobencilguanidina , Adulto , Cardiomiopatía Dilatada/complicaciones , Carvedilol , Método Doble Ciego , Femenino , Insuficiencia Cardíaca/complicaciones , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/efectos de los fármacos , Ventrículos Cardíacos/inervación , Humanos , Masculino , Persona de Mediana Edad , Norepinefrina/sangre , Cintigrafía , Radiofármacos , Sistema Nervioso Simpático/efectos de los fármacos , Resultado del Tratamiento , Disfunción Ventricular Izquierda/complicaciones
9.
Arq Bras Cardiol ; 85(2): 92-9, 2005 Aug.
Artículo en Portugués | MEDLINE | ID: mdl-16113846

RESUMEN

OBJECTIVE: To assess the myocardial ischemic load to previous and after myocardial revascularization. METHODS: Ninety-six randomized patients, carriers of multivessel coronary artery disease, stable angina, preserved left ventricular function, and exercise-induced myocardial ischemia treated with revascularization (SMR) or coronary angioplasty (TCA). Myocardial scintigraphy with 99mTc-Sestamibi was performed prior to and 6 months after myocardial revascularization. RESULTS: The SMR determined a significant greater index of complete revascularization (p=0.001), an increase in the number of maximum ergometric tests (p=0.001) and reduction in the number of positive ergometric tests with exercise angina (p=0.018). Both procedures provided an important improvement in the functional class of angina (p=0.001), an increase in the average value of double peak product (p=0.009), and the time of exercise tolerance (p<0.001), besides the reduction in the average value of the summed of exercise score (p<0.001) and the difference of the summed of scores (p<0.001) in both groups. CONCLUSION: TCA and SMR did not differ significantly concerning the reduction of myocardial ischemic load 6 months after the procedure. The myocardial revascularization was more complete with the SMR than the TCA, but it did not represent a significant factor for the reduction myocardial ischemic load.


Asunto(s)
Vasos Coronarios/diagnóstico por imagen , Isquemia Miocárdica/diagnóstico por imagen , Isquemia Miocárdica/terapia , Revascularización Miocárdica/métodos , Adulto , Anciano , Angina de Pecho/clasificación , Angina de Pecho/diagnóstico por imagen , Angina de Pecho/terapia , Angioplastia Coronaria con Balón , Prueba de Esfuerzo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Isquemia Miocárdica/cirugía , Estudios Prospectivos , Radiofármacos , Tecnecio Tc 99m Sestamibi , Tomografía Computarizada de Emisión de Fotón Único , Resultado del Tratamiento
10.
Stud Health Technol Inform ; 216: 653-7, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26262132

RESUMEN

Cardiac function can be assessed from displacement measurements in imaging modalities from nuclear medicine Using positron emission tomography (PET) image sequences with Rubidium-82, we propose and estimate the total Kinetic Energy Index (KEf) obtained from the velocity field, which was calculated using 3D optical flow(OF) methods applied over the temporal image sequence. However, it was found that the brightness of the image varied unexpectedly between frames, violating the constant brightness assumption of the OF method and causing large errors in estimating the velocity field. Therefore total brightness was equalized across image frames and the adjusted configuration tested with rest perfusion images acquired from individuals with normal (n=30) and low (n=33) cardiac function. For these images KEf was calculated as 0.5731±0.0899 and 0.3812±0.1146 for individuals with normal and low cardiac function respectively. The ability of KEf to properly classify patients into the two groups was tested with a ROC analysis, with area under the curve estimated as 0.906. To our knowledge this is the first time that KEf has been applied to PET images.


Asunto(s)
Transferencia de Energía/fisiología , Ventrículos Cardíacos/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Tomografía de Emisión de Positrones/métodos , Volumen Sistólico , Función Ventricular Izquierda/fisiología , Humanos , Imagenología Tridimensional/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
12.
Int J Cardiol ; 97(3): 447-53, 2004 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-15561332

RESUMEN

BACKGROUND: Rest single-photon emission computed tomographic (SPECT) perfusion imaging identifies acute myocardial ischemia in patients with chest pain in the emergency department; however, the costs are high and radioisotopic services are usually not available 24 h a day. Planar imaging through a portable gamma camera may be useful in this setting. However, planar imaging might be associated with less predictive values in comparison with a gated SPECT imaging. We sought to evaluate rest planar myocardial perfusion imaging for evaluation and triage of patients with suspected acute cardiac ischemia. METHODS: Patients within 6 h of chest pain onset and nondiagnostic electrocardiograms (ECGs) underwent planar myocardial perfusion imaging. Studies showing perfusion defects were considered suggestive of acute coronary syndromes. The results of planar scintigraphy were compared with the clinical diagnosis and outcomes. All patients were followed up and monitored for the occurrence of major cardiac events 120 days after hospital discharge. RESULTS: 71 patients underwent scintigraphy. Twenty-one (30%) patients had acute coronary syndromes, 15 (21%) had major cardiac events (8 had myocardial infarction and 7 underwent myocardial revascularization). Planar scintigraphy demonstrated perfusion defects in 21 patients, 16 (76%) patients with acute coronary syndromes, 12 (80%) patients who had major cardiac events and in 7 (88%) patients with myocardial infarction. The negative predictive value of planar scintigraphy was 90% for diagnosis of acute coronary syndromes and 94% for detecting major cardiac events. CONCLUSION: Early planar myocardial perfusion imaging allowed rapid and accurate risk stratification of emergency departments patients with possible myocardial ischemia and nondiagnostic ECGs.


Asunto(s)
Dolor en el Pecho/diagnóstico , Corazón/diagnóstico por imagen , Tecnecio Tc 99m Sestamibi , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/diagnóstico por imagen , Isquemia Miocárdica/diagnóstico por imagen , Cintigrafía
13.
Rev Assoc Med Bras (1992) ; 60(4): 311-7, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25211414

RESUMEN

OBJECTIVE: despite the technologic advances in myocardial perfusion imaging, we keep using an uncomfortable and sometimes impracticable patient position - supine with arms raised above the head (U). The purpose of this study was to investigate whether perfusion and functional cardiac gated SPECT scan results of acquisition U are equivalent to another position modality: supine with arms down at the sides of the trunk (D). METHODS AND RESULTS: we performed U acquisition and in sequence D acquisition in 120 patients (pts) using a one-day MPI (rest-gated/stress), with 99mTc-sestamibi (370 MBq and 1110 MBq). Images were processed by the iterative reconstruction method (OSEM). Rest (R) and stress (S) studies were scored using 17-segments model. Functional parameters (left ventricular ejection fraction, and volumes) were automatically obtained by the quantitative gated SPECT (QGS) program. According to the degree of stress defects observed in U study, the patients were categorized in two subgroups: normal (SSS ≤ 3 or < 5%) and abnormal (SSS>3 or ≥ 5%). Shoulder/back pain occurred in 23.3% of U patients and in 5% of D. No significant differences between U and D were found for SSS (p = 0.82) and SRS (p = 0.74) in normal group. In abnormal group, good correlation was found between U and D modes for SSS (Rho = 0.95, p = 0.0001) and SRS (Rho = 0.96 p = 0.0001), but the mean SSS (12.53 ± 7.54) and SRS (10.60 ± 7.08) values of D were significantly lower (p < 0.05) than SSS (13.43 ± 6.81) and SRS (11.33 ± 6.97) of U mode. Function measurements presented good correlations, except for end-diastolic volume (p = 0.0001). CONCLUSION: although D mode appears to be more comfortable and presented a good correlation with U values of SSS and SRS, in abnormal pts, the extent and severity of defects can be underestimated. Considering clinical implications of an accurate perfusion measurement, the acquisition with the arms down should be avoided.


Asunto(s)
Brazo , Imagen de Perfusión Miocárdica/métodos , Posicionamiento del Paciente/métodos , Posición Supina , Tomografía Computarizada de Emisión de Fotón Único/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Descanso , Volumen Sistólico
14.
Int J Cardiovasc Imaging ; 30(2): 415-23, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24253855

RESUMEN

Positron emission tomography with (18)F-fluorodeoxyglucose (FDG-PET) is considered the gold standard for myocardial viability. A pilot study was undertaken to compare FDG-PET using euglycemic hyperinsulinemic clamp before (18)F-fluorodeoxyglucose ((18)F-FDG) administration (PET-CLAMP) with a new proposed technique consisting of a 24-h low-carbohydrate diet before (18)F-FDG injection (PET-DIET), for the assessment of hypoperfused but viable myocardium (hibernating myocardium). Thirty patients with previous myocardial infarction were subjected to rest (99m)Tc-sestamibi-SPECT and two (18)F-FDG studies (PET-CLAMP and PET-DIET). Myocardial tracer uptake was visually scored using a 5-point scale in a 17-segment model. Hibernating myocardium was defined as normal or mildly reduced metabolism ((18)F-FDG uptake) in areas with reduced perfusion ((99m)Tc-sestamibi uptake) since (18)F-FDG uptake was higher than the degree of hypoperfusion-perfusion/metabolism mismatch indicating a larger flow defect. PET-DIET identified 79 segments and PET-CLAMP 71 as hibernating myocardium. Both methods agreed in 61 segments (agreement = 94.5 %, κ = 0.78). PET-DIET identified 230 segments and PET-CLAMP 238 as nonviable. None of the patients had hypoglycemia after DIET, while 20 % had it during CLAMP. PET-DIET compared with PET-CLAMP had a good correlation for the assessment of hibernating myocardium. To our knowledge, these data provide the first evidence of the possibility of myocardial viability assessment with this technique.


Asunto(s)
Dieta Baja en Carbohidratos , Fluorodesoxiglucosa F18 , Técnica de Clampeo de la Glucosa , Imagen de Perfusión Miocárdica/métodos , Aturdimiento Miocárdico/diagnóstico por imagen , Miocardio/patología , Tomografía de Emisión de Positrones , Radiofármacos , Adulto , Anciano , Circulación Coronaria , Estudios de Factibilidad , Femenino , Fluorodesoxiglucosa F18/metabolismo , Humanos , Masculino , Persona de Mediana Edad , Aturdimiento Miocárdico/metabolismo , Aturdimiento Miocárdico/fisiopatología , Miocardio/metabolismo , Proyectos Piloto , Valor Predictivo de las Pruebas , Radiofármacos/metabolismo , Tecnecio Tc 99m Sestamibi , Supervivencia Tisular , Tomografía Computarizada de Emisión de Fotón Único
15.
Arq Bras Cardiol ; 103(3): 192-200, 2014 Sep.
Artículo en Inglés, Portugués | MEDLINE | ID: mdl-25076179

RESUMEN

BACKGROUND: The investigation of stable coronary artery disease (CAD) and its treatment depend on risk stratification for decision-making on the need for cardiac catheterization and revascularization. OBJECTIVE: To analyze the procedures used in the diagnosis and invasive treatment of patients with CAD, at the Brazilian Unified Health System (SUS) in the cities of Curitiba, São Paulo and at InCor-FMUSP. METHODS: Retrospective, descriptive, observational study of the diagnostic and therapeutic itineraries of the Brazilian public health care system patient, between groups submitted or not to prior noninvasive tests to invasive cardiac catheterization. Stress testing, stress echocardiography, perfusion scintigraphy, catheterization and percutaneous or surgical revascularization treatment procedures were quantified and the economic impact of the used strategies. RESULTS: There are significant differences in the assessment of patients with suspected or known CAD in the metropolitan region in the three scenarios. Although functional testing procedures are most often used the direct costs of these procedures differ significantly (6.1% in Curitiba, 20% in São Paulo and 27% in InCor-FMUSP). Costs related to the procedures and invasive treatments represent 59.7% of the direct costs of SUS in São Paulo and 87.2% in Curitiba. In InCor-FMUSP, only 24.3% of patients with stable CAD submitted to CABG underwent a noninvasive test before the procedure. CONCLUSION: Although noninvasive functional tests are the ones most often requested for the assessment of patients with suspected or known CAD most of the costs are related to invasive procedures/treatments. In most revascularized patients, the documentation of ischemic burden was not performed by SUS.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/terapia , Programas Nacionales de Salud/estadística & datos numéricos , Brasil , Cateterismo Cardíaco/economía , Cateterismo Cardíaco/estadística & datos numéricos , Enfermedad de la Arteria Coronaria/economía , Vías Clínicas , Ecocardiografía/economía , Ecocardiografía/estadística & datos numéricos , Prueba de Esfuerzo/economía , Prueba de Esfuerzo/estadística & datos numéricos , Femenino , Gastos en Salud , Humanos , Masculino , Programas Nacionales de Salud/economía , Intervención Coronaria Percutánea/economía , Intervención Coronaria Percutánea/estadística & datos numéricos , Cintigrafía/economía , Cintigrafía/estadística & datos numéricos , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo
16.
J Nucl Med ; 55(10): 1591-7, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25214642

RESUMEN

UNLABELLED: Bone marrow is an important extranodal site in diffuse large B-cell lymphoma (DLBCL), and marrow histology has been incorporated into the new National Comprehensive Cancer Network international prognostic index. Marrow involvement demonstrated histologically confers poor prognosis but is identified by staging PET in more cases. How information from staging PET and biopsy should be combined to optimize outcome prediction remains unclear. METHODS: The International Atomic Energy Agency sponsored a prospective international cohort study to better define the use of PET in DLBCL. As a planned subsidiary analysis, we examined the interplay of marrow involvement identified by PET and biopsy on clinical outcomes. RESULTS: Eight countries contributed 327 cases with a median follow-up of 35 mo. The 2-y outcomes of cases with no evidence of marrow involvement (n = 231) were 81% (95% confidence interval [CI], 76%-86%) for event-free survival (EFS) and 88% (83%-91%) for overall survival (OS); cases identified only on PET (n = 61), 81% (69%-89%) for EFS and 88% (77%-94%) for OS; cases indentified only on biopsy (n = 10), 80% (41%-95%) for EFS and 100% for OS; or cases identified by both PET and biopsy (n = 25), 45% (25%-64%) for EFS and 55% (32%-73%) for OS. The hazard ratios for PET-negative/biopsy-negative cases versus PET-positive/biopsy-positive cases were 2.67 (95% CI, 1.48-4.79) for EFS and 3.94 (1.93-8.06) for OS. CONCLUSION: This large study demonstrates that positive iliac crest biopsy histology only confers poor prognosis for patients who also have abnormal marrow (18)F-FDG uptake identified on the staging PET scan. Abnormal (18)F-FDG uptake in marrow, when iliac crest biopsy histology is normal, has no adverse effect on outcomes.


Asunto(s)
Células de la Médula Ósea/citología , Linfoma de Células B Grandes Difuso/diagnóstico por imagen , Tomografía de Emisión de Positrones/métodos , Adulto , Biopsia , Médula Ósea/patología , Supervivencia sin Enfermedad , Femenino , Humanos , Linfoma de Células B Grandes Difuso/diagnóstico , Linfoma de Células B Grandes Difuso/mortalidad , Linfoma de Células B Grandes Difuso/patología , Masculino , Persona de Mediana Edad , Modelos Estadísticos , Pronóstico , Estudios Prospectivos , Resultado del Tratamiento
17.
Hematol., Transfus. Cell Ther. (Impr.) ; 40(3): 245-249, July-Sept. 2018. tab, ilus
Artículo en Inglés | LILACS | ID: biblio-953832

RESUMEN

ABSTRACT Objective: To investigate, in a large prospective multicenter study, whether 2-[18F]-fluoro-2-deoxy-D-glucose-positron emission tomography is sufficiently accurate to identify clinically important bone marrow involvement by Hodgkin's lymphoma to replace routine bone marrow biopsy in a developing tropical country. Methods: Patients newly diagnosed with Hodgkin's lymphoma were recruited from six cancer centers in Brazil. All were staged by the results of positron emission tomography/computed tomography that were centrally reviewed and by iliac crest bone marrow biopsy. Patients were classified as having marrow disease if they had lymphoma identified by marrow biopsy histology or had focal 2-[18F]-fluoro-2-deoxy-D-glucose marrow uptake that resolved following chemotherapy. Results: A total of 246 participants were recruited from six different centers and 62 (25.2%) were judged to have Hodgkin's lymphoma in the bone marrow. Positron emission tomography and biopsies were concordant in 206 patients (83%). Positron emission tomography correctly identified marrow disease in 59/62 patients (95.1%) and marrow biopsy in 25/62 patients (40.3%). In 22/62 (35.4%) patients, the two techniques were concordant in the diagnosis of marrow involvement. Of the forty discordant results, positron emission tomography found bone marrow involvement in 37 patients, upstaging 22 to stage IV and having an impact on therapeutic decision in nine cases given their reallocation from early to advanced stage. Three false negative positron emission tomography results were obtained with bone marrow biopsy giving positive findings. All three cases were classified as stage IV regardless of bone marrow findings implying no modification in the clinical management. The sensitivity, specificity and accuracy of positron emission tomography for detecting bone marrow disease were 95%, 100% and 98% and for bone marrow biopsy they were 40%, 100% and 84%, respectively. Conclusion: We conclude that positron emission tomography can replace marrow biopsy in Brazilian patients with Hodgkin's lymphoma without compromising clinical management.


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Médula Ósea , Enfermedad de Hodgkin , Prácticas Clínicas , Tomografía de Emisión de Positrones , Linfoma , Biopsia
19.
Am J Cardiol ; 106(3): 310-5, 2010 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-20643238

RESUMEN

Recently, stress myocardial computed tomographic perfusion (CTP) was shown to detect myocardial ischemia. Our main objective was to evaluate the feasibility of dipyridamole stress CTP and compare it to single-photon emission computed tomography (SPECT) to detect significant coronary stenosis using invasive conventional coronary angiography (CCA; stenosis >70%) as the reference method. Thirty-six patients (62 +/- 8 years old, 20 men) with previous positive results with SPECT (<2 months) as the primary inclusion criterion and suspected coronary artery disease underwent a customized multidetector-row CT protocol with myocardial perfusion evaluation at rest and during stress and coronary CT angiography (CTA). Multidetector-row computed tomography was performed in a 64-slice scanner with dipyridamole stress perfusion acquisition before a second perfusion/CT angiographic acquisition at rest. Independent blinded observers performed analysis of images from CTP, CTA, and CCA. All 36 patients completed the CT protocol with no adverse events (mean radiation dose 14.7 +/- 3.0 mSv) and with interpretable scans. CTP results were positive in 27 of 36 patients (75%). From the 9 (25%) disagreements, 6 patients had normal coronary arteries and 2 had no significant stenosis (8 false-positive results with SPECT, 22%). The remaining patient had an occluded artery with collateral flow confirmed by conventional coronary angiogram. Good agreement was demonstrated between CTP and SPECT on a per-patient analysis (kappa 0.53). In 26 patients using CCA as reference, sensitivity, specificity, and positive and negative predictive values were 88.0%, 79.3%, 66.7%, and 93.3% for CTP and 68.8, 76.1%, 66.7%, and 77.8%, for SPECT, respectively (p = NS). In conclusion, dipyridamole CT myocardial perfusion at rest and during stress is feasible and results are similar to single-photon emission CT scintigraphy. The anatomical-perfusion information provided by this combined CT protocol may allow identification of false-positive results by SPECT.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico , Dipiridamol , Tomografía Computarizada Espiral , Vasodilatadores , Cateterismo Cardíaco , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Prueba de Esfuerzo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Dosis de Radiación , Descanso , Sensibilidad y Especificidad , Tomografía Computarizada de Emisión de Fotón Único
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA