Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 447
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Nano Lett ; 24(8): 2574-2580, 2024 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-38349338

RESUMEN

The highly programmable and responsive molecular recognition properties of DNA provide unparalleled opportunities for fabricating dynamic nanostructures capable of structural transformation in response to various external stimuli. However, they typically operate in tightly controlled environments because certain conditions (ionic strength, pH, temperature, etc.) must be met for DNA duplex formation. In this study, we adopted site-specific enzymatic ligation and DNA-based layer-by-layer thin film fabrication to build shape-morphing DNA-linked nanoparticle films operational in a broad range of environments. The ligated films remained intact in unusual conditions such as pure water and high temperature causing dissociation of DNA duplexes and showed predictable and reversible shape morphing in response to various environmental changes and DNA exchange reactions. Furthermore, domain-selective ligation combined with photoinduced interlayer mixing allowed for the fabrication of unusual edge-sealed double-layered films through midlayer etching, which is difficult to realize by other methods.


Asunto(s)
Nanopartículas , Nanoestructuras , ADN/química , Agua , Temperatura
2.
Bioorg Chem ; 145: 107222, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38401359

RESUMEN

Ubiquitination is a representative post-translational modification that tags target proteins with ubiquitin to induce protein degradation or modify their functions. Deubiquitinating enzymes (DUBs) play a crucial role in reversing this process by removing ubiquitin from target proteins. Among them, USP2a has emerged as a promising target for cancer therapy due to its oncogenic properties in various cancer types, but its inhibitors have been limited. In this study, our aim was to optimize the structure of ML364, a USP2a inhibitor, and synthesize a series of its derivatives to develop potent USP2a inhibitors. Compound 8v emerged as a potential USP2a inhibitor with lower cytotoxicity compared to ML364. Cellular assays demonstrated that compound 8v effectively reduced the levels of USP2a substrates and attenuated cancer cell growth. We confirmed its direct interaction with the catalytic domain of USP2a and its selective inhibitory activity against USP2a over other USP subfamily proteins (USP7, 8, or 15). In conclusion, compound 8v has been identified as a potent USP2a inhibitor with substantial potential for cancer therapy.


Asunto(s)
Endopeptidasas , Ubiquitina , Endopeptidasas/química , Proteolisis , Ubiquitina/metabolismo , Ubiquitinación
3.
J Clin Periodontol ; 51(3): 330-337, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38087817

RESUMEN

AIM: To investigate whether transmucosal healing is as effective as submerged healing in terms of buccal bone regeneration when guided bone regeneration (GBR) is performed simultaneously with implant placement. MATERIALS AND METHODS: In six dogs, buccal dehiscence defects were created in the edentulous mandibular ridge, sized 5 × 5 × 3 mm (length × height × depth). In each defect, a bone-level implant was placed, and four experimental groups were randomly assigned as follows: (i) transmucosal healing with GBR (T-GBR), (ii) transmucosal healing without GBR (T-control), (iii) submerged healing with GBR (S-GBR) and (iv) submerged healing without GBR (S-control). Data analyses were based on histological slides 5 months after implant placement. RESULTS: The T-GBR group showed significant differences compared to the control groups regarding defect height resolution, buccal bone thickness and mineralized tissue area (p < .05), but showed no significant differences when compared with the S-GBR group (p > .05). CONCLUSIONS: The mode of healing (transmucosal vs. submerged) does not influence bone regeneration at implant sites. The clinician may therefore choose the approach based on further clinical and patient-specific parameters.


Asunto(s)
Aumento de la Cresta Alveolar , Implantes Dentales , Animales , Perros , Regeneración Ósea , Implantación Dental Endoósea , Regeneración Tisular Guiada Periodontal , Cicatrización de Heridas
4.
J Clin Periodontol ; 51(6): 766-773, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38356227

RESUMEN

AIM: To test whether early implant placement into the extraction socket containing an uncalcified provisional matrix leads to successful osseointegration and stable marginal bone levels. MATERIALS AND METHODS: In six mongrel dogs, the mandibular molars were extracted. Three weeks later, early implant placement was performed according to three experimental protocols: (i) flapless implant placement with preservation of the provisional matrix; (ii) flap elevation, socket debridement and implant placement; and (iii) flap elevation, socket debridement, implant placement and guided bone regeneration (GBR). One untreated extraction socket served as a control group. Data analyses were based on histologic slides 3 months after implant placement. RESULTS: There were no differences in bone-to-implant contact between the three experimental groups (66.97%, 58.89% and 60.89%, respectively) (inter-group comparison p = .42). Marginal bone levels, first bone-to-implant contact as well as the thickness of the connective tissue did not reveal any significant differences between the groups (p = .85, .60 and .65, respectively). CONCLUSIONS: Flapless early implant placement into posterior extraction sockets was as effective as an open flap approach in conjunction with GBR. Mineralization of the socket seems to occur irrespective of the presence of dental implants or biomaterials.


Asunto(s)
Oseointegración , Alveolo Dental , Animales , Perros , Oseointegración/fisiología , Alveolo Dental/cirugía , Extracción Dental , Colgajos Quirúrgicos/cirugía , Regeneración Tisular Guiada Periodontal/métodos , Implantación Dental Endoósea/métodos , Implantes Dentales , Mandíbula/cirugía , Desbridamiento , Tejido Conectivo , Diente Molar , Carga Inmediata del Implante Dental/métodos
5.
Artículo en Inglés | MEDLINE | ID: mdl-38949573

RESUMEN

OBJECTIVE: To investigate the early impact of plaque accumulation in a buccal dehiscence defect on peri-implant marginal bone resorption. MATERIALS AND METHODS: In six male Mongrel dogs, four dental implants were placed in the posterior maxilla on both sides (two implants per side). Based on the group allocation, each implant was randomly assigned to one of the following four groups to decide whether buccal dehiscence defect was prepared and whether silk ligation was applied at 8 weeks post-implant placement for peri-implantitis induction: UC (no defect without ligation); UD (defect without ligation); LC (no defect with ligation); and LD (defect with ligation) groups. Eight weeks after disease induction, the outcomes from radiographic and histologic analyses were statistically analyzed (p < .05). RESULTS: Based on radiographs, the exposed area of implant threads was smallest in group UC (p < .0083). Based on histology, both the distances from the implant platform to the first bone-to-implant contact point and to the bone crest were significantly longer in the LD group (p < .0083). In the UD group, some spontaneous bone fill occurred from the base of the defect at 8 weeks after implant placement. The apical extension of inflammatory cell infiltrate was significantly more prominent in the LD and LC groups compared to the UC group (p < .0083). CONCLUSION: Plaque accumulated on the exposed implant surface had a negative impact on maintaining the peri-implant marginal bone level, especially when there was a dehiscence defect around the implant.

6.
Clin Oral Implants Res ; 35(3): 330-339, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38126121

RESUMEN

OBJECTIVE: To evaluate the effect of a self-retaining block-type bone substitute (srBB) on the dimensional stability of the horizontal ridge width at the coronal level in a buccal dehiscence model. MATERIALS AND METHODS: Four box-shaped bone defects with a buccal dehiscence were surgically prepared in the partially edentulous mandible (n = 6). Experimental biomaterials were randomly assigned to each site: (1) Control group: no treatment, (2) particle-type bone substitute (PBS) group, (3) collagenated soft block bone substitute (csBB) group, and (4) self-retaining synthetic block bone (srBB) group. In all grafted groups, a collagen membrane covered the biomaterials. At 16 weeks, clinical, histological, and radiographic analyses were performed. RESULTS: Three of the six blocks in the srBB group became exposed and fell out during the first week after surgery. Therefore, the remaining three specimens were renamed RsrBB group. The RsrBB group showed an increase horizontal ridge compared to the pristine bone width at 2-4 mm below the CEJ, while the other groups showed resorption (augmented width at 2 mm below: 4.2, 42.4, 36.2, and 110.1% in the control, PBS, csBB, and RsrBB groups, respectively). The mineralized bone area was largest in the RsrBB group (4.74, 3.44, 5.67, and 7.77 mm2 in the control, PBS, csBB, and RsrBB groups, respectively.). CONCLUSIONS: The srBB group demonstrated the highest volume stability at the coronal level. These findings would potentially suggest that self-retaining block bone substitute might be a good candidate for alveolar ridge preservation.


Asunto(s)
Pérdida de Hueso Alveolar , Aumento de la Cresta Alveolar , Sustitutos de Huesos , Humanos , Pérdida de Hueso Alveolar/cirugía , Aumento de la Cresta Alveolar/métodos , Sustitutos de Huesos/uso terapéutico , Colágeno , Extracción Dental , Alveolo Dental/cirugía
7.
Cell Mol Life Sci ; 80(4): 112, 2023 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-37004621

RESUMEN

Recently, a number of reports on the importance of USP35 in cancer have been published. However, very little is known about the exact mechanism by which USP35 activity is regulated. Here, we show the possible regulation of USP35 activity and the structural specificity affecting its function by analyzing various fragments of USP35. Interestingly, the catalytic domain of USP35 alone does not exhibit deubiquitinating activity; in contrast, the C-terminal domain and insertion region in the catalytic domain is required for full USP35 activity. Additionally, through its C-terminal domain, USP35 forms a homodimer that prevents USP35 degradation. CHIP bound to HSP90 interacts with and ubiquitinates USP35. However, when fully functional USP35 undergoes auto-deubiquitination, which attenuates CHIP-mediated ubiquitination. Finally, USP35 dimer is required for deubiquitination of the substrate Aurora B and regulation of faithful mitotic progression. The properties of USP35 identified in this study are a unique homodimer structure, regulation of deubiquitinating activity through this, and utilization of a novel E3 ligase involved in USP35 auto-deubiquitination, which adds another complexity to the regulation of deubiquitinating enzymes.


Asunto(s)
Neoplasias , Ubiquitina-Proteína Ligasas , Humanos , Ubiquitina-Proteína Ligasas/metabolismo , Endopeptidasas/genética , Endopeptidasas/metabolismo , Ubiquitinación
8.
J Adolesc ; 96(2): 322-336, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38010232

RESUMEN

INTRODUCTION: Adolescents are experiencing high rates of depressive symptoms, with negative consequences to their long-term health. Group-based, mindful self-compassion programs show promise in mitigating the development of more significant depression in at-risk adolescents. However, the lack of well-designed, active control conditions has limited the ability to examine the efficacy of such interventions. METHODS: Fifty-nine adolescents (Mage = 15.81, 70% female) with subsyndromal depressive symptoms from the Southeastern US were randomized to group-based Mindful Self-Compassion for Teens (N = 30) or a newly developed active control Healthy Lifestyles group (N = 29) during 2018 and 2019. Participants attended 8 weekly "main" sessions followed by 6 monthly continuation sessions. The feasibility and acceptability of participation in both groups were measured using attrition, attendance, credibility, and satisfaction data. Depression scores were collected weekly, and self-compassion scores were collected five times across 36 weeks. RESULTS: Both groups were equally feasible and acceptable during the 8-week program period; however, monthly continuation sessions were poorly attended in both groups. The risk of developing clinically significant depression was 2.6 times higher in the control group compared with the self-compassion group (p = .037) across 36 weeks. Depression significantly decreased in the self-compassion group, while it significantly increased in the control group. Both groups increased significantly in reports of self-compassion. These findings are on par with results noting the efficacy of cognitive-based interventions for high-risk adolescents; follow-up studies with larger sample sizes should be conducted to confirm these findings. CONCLUSIONS: Initial examination suggests Mindful Self-Compassion for Teens programming is feasible, acceptable, and efficacious in preventing the development of clinically significant depression in adolescents with subsyndromal depression. Future studies may benefit from refinements to the self-compassion measurement and/or the attention control condition; moreover, larger sample sizes are needed to confirm results.


Asunto(s)
Depresión , Atención Plena , Humanos , Adolescente , Femenino , Masculino , Depresión/terapia , Autocompasión , Estudios de Factibilidad , Atención Plena/métodos , Estudios de Seguimiento
9.
Mikrochim Acta ; 191(7): 400, 2024 06 15.
Artículo en Inglés | MEDLINE | ID: mdl-38879615

RESUMEN

Ultrathin molecularly imprinted polymer (MIP) films were deposited on the surfaces of ZnO nanorods (ZNRs) and nanosheets (ZNSs) by electropolymerization to afford extended-gate field-effect transistor sensors for detecting phenytoin (PHT) in plasma. Molecular imprinting efficiency was optimized by controlling the contents of functional monomers and the template in the precursor solution. PHT sensing was performed in plasma solutions with various concentrations by monitoring the drain current as a function of drain voltage under an applied gate voltage of 1.5 V. The reliability and reproducibility of the fabricated sensors were evaluated through a solution treatment process for complete PHT removal and PHT adsorption-removal cycling, while selectivity was examined by analyzing responses to chemicals with structures analogous to that of PHT. Compared with the ZNS/extracted-MIP sensor and sensors with non-imprinted polymer (NIP) films, the ZNR/extracted-MIP sensor showed superior responses to PHT-containing plasma due to selective PHT adsorption, achieving an imprinting factor of 4.23, detection limit of 12.9 ng/mL, quantitation limit of 53.0 ng/mL, and selectivity coefficients of 3-4 (against tramadol) and ~ 5 (against diphenhydramine). Therefore, we believe that the MIP-based ZNR sensing platform is promising for the practical detection of PHT and other drugs and evaluation of their proper dosages.


Asunto(s)
Anticonvulsivantes , Límite de Detección , Polímeros Impresos Molecularmente , Fenitoína , Transistores Electrónicos , Óxido de Zinc , Anticonvulsivantes/sangre , Anticonvulsivantes/análisis , Polímeros Impresos Molecularmente/química , Óxido de Zinc/química , Fenitoína/sangre , Fenitoína/análisis , Fenitoína/química , Humanos , Impresión Molecular , Nanotubos/química , Adsorción , Reproducibilidad de los Resultados , Polímeros/química
10.
Artículo en Inglés | MEDLINE | ID: mdl-38750786

RESUMEN

BACKGROUND: Bone marrow stimulation (BMS), a procedure involving the creation of multiple channels in the greater tuberosity, is often performed alongside arthroscopic rotator cuff repair (ARCR). This study evaluated the effect of BMS on clinical and structural outcomes following ARCR. METHOD: This study involved 204 patients with small, medium, and large full-thickness rotator cuff tears. In all, 103 patients who underwent BMS and ARCR made up the BMS group, while the 101 patients who only had ARCR made up the control group with randomization. Clinical and functional outcomes were assessed before and at 3 months, 6 months, 1 year, and 2 years after surgery, using parameters such as range of motion, functional scores (ASES and constant score), and clinical scores (VAS). Tendon integrity was also examined postoperatively via ultrasound at 6 months and 2 years. RESULTS: There were no significant differences between the two groups concerning range of motion, functional scores (ASES score and constant score), and clinical score (VAS) during the 2-year post-surgery period (all p>0.05). Similarly, the rotator cuff retear rate, as assessed using ultrasonographic tendon integrity checks over 2 years post-surgery, did not significantly vary between the groups (all p>0.05). CONCLUSION: There were no significant disparities in functional scores and clinical outcomes between the BMS and control groups. Further, no significant differences were observed in tendon integrity post-surgery. Therefore, the inclusion or exclusion of BMS is not anticipated to influence the postoperative outcome in ARCR for patients with small, medium, or large rotator cuff tears.

11.
J Esthet Restor Dent ; 2024 Apr 09.
Artículo en Inglés | MEDLINE | ID: mdl-38591169

RESUMEN

OBJECTIVES: To evaluate clinical, clinician- and patient-reported outcomes (PROs) of two adjacent single posterior implants immediately loaded with definitive single crowns up to 1 year. Ten patients in need of two adjacent posterior single implants were included. All implants were placed applying a fully digital workflow. Definitive screw-retained single zirconia crowns were delivered within 72 h after implant placement. Clinical parameters, patient- and clinician-reported outcomes were assessed up to 1 year of follow-up. CLINICAL CONSIDERATIONS: Clinical outcomes remained stable, with no implant failures or technical and biological complications throughout the observation period. Patient satisfaction was very high at baseline (crown delivery) and remained consistently high at 6 and 12 months of follow-up. Crown insertion 3 days after implant placement was rated as an easy procedure by clinicians. CONCLUSIONS: Two adjacent single implants with immediate definitive restorations (<72 h) in the posterior region appear to be a viable and easy treatment option to shorten the overall treatment time and potentially enhancing patient satisfaction. However, randomized controlled trials are needed to confirm the advantages of this treatment protocol over a delayed loading approach. CLINICAL SIGNIFICANCE: In selected cases, immediate implant loading with definitive restorations in the posterior region appears a valuable and straightforward option to shorten the overall treatment time.

12.
J Prosthet Dent ; 2024 May 25.
Artículo en Inglés | MEDLINE | ID: mdl-38797573

RESUMEN

STATEMENT OF PROBLEM: Interest is growing in immediately loading definitive implant-supported prostheses. However, it appears that implant protocols are evolving faster than their scientific validation. PURPOSE: The purpose of this scoping review was to identify the current trends, feasibility, and clinical outcomes of a specific clinical loading scenario (type A), where a single definitive implant-retained restoration is delivered within 3 days. The focus question was "In partially edentulous patients requiring an implant-retained prosthesis (population), is immediate loading with a definitive restoration (concept) a viable treatment option (context)?" MATERIAL AND METHODS: An electronic search was conducted in the PubMed, CENTRAL, Scopus, Embase, and Web of Science databases. Two authors independently reviewed the studies, screened titles and abstracts, and performed full-text analysis. Cross-reference checks within the bibliography of included studies, relevant reviews, and guideline were conducted. Bibliometric information and study details were extracted. RESULTS: The search identified 2568 titles after removing duplicates. Four studies involving 91 participant and 100 implant-retained restorations were included in this scoping review. The selected articles were a randomized controlled trial (RCT), a prospective clinical study, and the remaining 2 were case series. The follow-up periods investigated ranged from 6 to 26 months. All studies evaluated marginal bone loss as a primary outcome, and only 1 implant failure was reported. Patient-reported outcome measures were favorable, and no major biological or technical complications were reported in any study. CONCLUSIONS: Immediate loading with a definitive restoration within 3 days appears to be a suitable approach in specific clinical situations.

13.
Molecules ; 29(6)2024 Mar 19.
Artículo en Inglés | MEDLINE | ID: mdl-38542998

RESUMEN

The increasing utilization of artificial intelligence algorithms in drug development has proven to be highly efficient and effective. One area where deep learning-based approaches have made significant contributions is in drug repositioning, enabling the identification of new therapeutic applications for existing drugs. In the present study, a trained deep-learning model was employed to screen a library of FDA-approved drugs to discover novel inhibitors targeting JAK2. To accomplish this, reference datasets containing active and decoy compounds specific to JAK2 were obtained from the DUD-E database. RDKit, a cheminformatic toolkit, was utilized to extract molecular features from the compounds. The DeepChem framework's GraphConvMol, based on graph convolutional network models, was applied to build a predictive model using the DUD-E datasets. Subsequently, the trained deep-learning model was used to predict the JAK2 inhibitory potential of FDA-approved drugs. Based on these predictions, ribociclib, topiroxostat, amodiaquine, and gefitinib were identified as potential JAK2 inhibitors. Notably, several known JAK2 inhibitors demonstrated high potential according to the prediction results, validating the reliability of our prediction model. To further validate these findings and confirm their JAK2 inhibitory activity, molecular docking experiments were conducted using tofacitinib-an FDA-approved drug for JAK2 inhibition. Experimental validation successfully confirmed our computational analysis results by demonstrating that these novel drugs exhibited comparable inhibitory activity against JAK2 compared to tofacitinib. In conclusion, our study highlights how deep learning models can significantly enhance virtual screening efforts in drug discovery by efficiently identifying potential candidates for specific targets such as JAK2. These newly discovered drugs hold promises as novel JAK2 inhibitors deserving further exploration and investigation.


Asunto(s)
Inteligencia Artificial , Reposicionamiento de Medicamentos , Simulación del Acoplamiento Molecular , Reproducibilidad de los Resultados , Redes Neurales de la Computación
14.
Br J Nutr ; : 1-9, 2023 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-37184085

RESUMEN

Blood carotenoid concentration measurement is considered the gold standard for fruit and vegetable (F&V) intake estimation; however, this method is invasive and expensive. Recently, skin carotenoid status (SCS) measured by optical sensors has been evaluated as a promising parameter for F&V intake estimation. In this cross-sectional study, we aimed to validate the utility of resonance Raman spectroscopy (RRS)-assessed SCS as a biomarker of F&V intake in Korean adults. We used data from 108 participants aged 20-69 years who completed SCS measurements, blood collection and 3-d dietary recordings. Serum carotenoid concentrations were quantified using HPLC, and dietary carotenoid and F&V intakes were estimated via 3-d dietary records using a carotenoid database for common Korean foods. The correlations of the SCS with serum carotenoid concentrations, dietary carotenoid intake and F&V intake were examined to assess SCS validity. SCS was positively correlated with total serum carotenoid concentration (r = 0·52, 95 % CI = 0·36, 0·64, P < 0·001), serum ß-carotene concentration (r = 0·60, 95 % CI = 0·47, 0·71, P < 0·001), total carotenoid intake (r = 0·20, 95 % CI = 0·01, 0·37, P = 0·04), ß-carotene intake (r = 0·30, 95 % CI = 0·11, 0·46, P = 0·002) and F&V intake (r = 0·40, 95 % CI = 0·23, 0·55, P < 0·001). These results suggest that SCS can be a valid biomarker of F&V intake in Korean adults.

15.
J Chem Inf Model ; 63(21): 6487-6500, 2023 11 13.
Artículo en Inglés | MEDLINE | ID: mdl-37906702

RESUMEN

Machine learning algorithms have been increasingly applied in drug development due to their efficiency and effectiveness. Machine learning-based drug repurposing can contribute to the identification of novel therapeutic applications for drugs with other indications. The current study used a trained machine learning model to screen a vast chemical library for new JAK2 inhibitors, the biological activities of which were reported. Reference JAK2 inhibitors, comprising 1911 compounds, have experimentally determined IC50 values. To generate the input to the machine learning model, reference compounds were subjected to RDKit, a cheminformatic toolkit, to extract molecular descriptors. A Random Forest Regression model from the Scikit-learn machine learning library was applied to obtain a predictive regression model and to analyze each molecular descriptor's role in determining IC50 values in the reference data set. Then, IC50 values of the library compounds, comprised of 1,576,903 compounds, were predicted using the generated regression model. Interestingly, some compounds that exhibit high IC50 values from the prediction were reported to possess JAK inhibition activity, which indicates the limitations of the prediction model. To confirm the JAK2 inhibition activity of predicted compounds, molecular docking and molecular dynamics simulation were carried out with the JAK inhibitor reference compound, tofacitinib. The binding affinity of docked compounds in the active region of JAK2 was also analyzed by the gmxMMPBSA approach. Furthermore, experimental validation confirmed the results from the computational analysis. Results showed highly comparable outcomes concerning tofacitinib. Conclusively, the machine learning model can efficiently improve the virtual screening of drugs and drug development.


Asunto(s)
Reposicionamiento de Medicamentos , Inhibidores de las Cinasas Janus , Simulación del Acoplamiento Molecular , Simulación de Dinámica Molecular , Janus Quinasa 2 , Aprendizaje Automático , Inhibidores de las Cinasas Janus/farmacología
16.
J Clin Periodontol ; 50(3): 358-367, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36330669

RESUMEN

AIM: It has been proposed that platelet-rich fibrin (PRF) can be used to support bone regeneration during alveolar ridge augmentation. The aim of this study was to determine whether an approach utilizing PRF provides similar performance to the established guided bone regeneration (GBR) procedure. MATERIALS AND METHODS: Two-wall defects were surgically created in beagle dogs and treated in three experimental groups: (i) a sticky bone (SB) substitute prepared using liquid PRF and deproteinized porcine bone mineral (DPBM); (ii) SB covered with solid PRF compressed into a membrane; and (iii) GBR performed using DPBM covered by a collagen membrane. Quantitative reverse-transcription polymerase chain reaction was applied to the specimen after 1 week of healing, and microcomputed tomography (micro-CT) and histological outcomes were analysed after 8 weeks of healing. RESULTS: Compared with GBR, PRF resulted in a moderate increase in the expression levels of osteoblast and osteoclast markers, osteocalcin, and calcitonin receptor. Moreover, PRF modestly increased angiogenesis and the inflammation markers vascular endothelial growth factor (VEGF) and IL-6. Micro-CT and histological analyses confirmed the expected increased alveolar ridge area, with no significant differences between the three groups. Consistently, graft consolidation, as indicated by new bone formation at the defect site, did not differ significantly between groups. CONCLUSIONS: The present results demonstrate that PRF-based approaches perform comparably to the established GBR procedure in terms of the consolidation of DPBM in two-wall alveolar defects.


Asunto(s)
Sustitutos de Huesos , Fibrina Rica en Plaquetas , Perros , Porcinos , Animales , Microtomografía por Rayos X , Factor A de Crecimiento Endotelial Vascular , Regeneración Ósea
17.
Clin Oral Implants Res ; 34(2): 116-126, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36458928

RESUMEN

BACKGROUND: The fixture thread depth reportedly influences the primary stability of dental implant, but its effect on the positional accuracy in immediate implant placement has not been reported previously. MATERIALS AND METHODS: Fifty-six single-rooted, anterior and premolar teeth were extracted from six human cadavers, followed by installing either regular-threaded implants (RT group, N = 30) or deep-threaded implants (DT group, N = 26) completely relying on the surgical guide. Optical impressions taken after osteotomy and fixture installation were superimposed with the preoperative virtual planning data to measure the vertical, angular, platform and apex deviations that occurred during osteotomy and installation. RESULTS: While the osteotomy deviations were similar between the two groups, the angular and apex deviation of the DT group (2.67 ± 2.56°; 1.04 ± 0.49 mm, respectively) were significantly larger than those of the RT group (1.61 ± 1.04°; 0.67 ± 0.41 mm, respectively) during installation (p < .05). When the installation deviations were analysed in the anterior and premolar areas separately, the angular, platform and apex deviations of the DT group (3.05 ± 3.26°; 0.75 ± 0.32 mm; 1.08 ± 0.56 mm, respectively) were significantly larger than those of the RT group (1.56 ± 0.73°, 0.59 ± 0.28 mm; 0.62 ± 0.38 mm, respectively) in the anterior site (p < .05), whereas there was no significant intergroup difference in the premolar site. CONCLUSION: In immediate-implant surgery, using an implant with a deeper thread might increase the deviations during installation, especially in the anterior area.


Asunto(s)
Implantes Dentales , Cirugía Asistida por Computador , Humanos , Implantación Dental Endoósea , Tomografía Computarizada de Haz Cónico , Cadáver , Diseño Asistido por Computadora , Imagenología Tridimensional
18.
Mikrochim Acta ; 190(7): 265, 2023 06 19.
Artículo en Inglés | MEDLINE | ID: mdl-37336828

RESUMEN

Novel detection method has been developed to explore changes in mechanical bending angles on a bilayer of polyethylene terephthalate (PET) and molecularly imprinted polymer (MIP). For an ovalbumin (OVA)-imprinted hydrogel layer, functional monomers were employed to achieve sufficient binding effect in the polymer matrix. The OVA amount added in the MIP precursor solution and the dimensions of OVA-imprinted hydrogel (MIH) strips were controlled to maximize the change in bending angles as an OVA sensing response within a valid detection range. The sensing behaviors were determined by monitoring the difference in the bending angles via protein adsorption based on the swelling-induced deformation of the OVA-extracted hydrogel (E-MIH) strip. The equilibrium adsorption capacity of the E-MIH strip was calculated via the Bradford protein assay. The detection limit, quantification limit, and imprinting factor were calculated. To compare the selectivity coefficients, the adsorption behaviors of three proteins were investigated. Finally, the reusability of the E-MIH strip was explored via repeated adsorption and extraction. Based on the results, the E-MIH strips demonstrated a promising protein sensing platform monitoring mechanical bending angles affected by swelling deformation.


Asunto(s)
Hidrogeles , Proteínas , Ovalbúmina , Polímeros , Polímeros Impresos Molecularmente
19.
Sensors (Basel) ; 23(5)2023 Feb 25.
Artículo en Inglés | MEDLINE | ID: mdl-36904772

RESUMEN

This study proposes an air circulation system that can forcibly circulate the lowest cold air to the top of indoor smart farms, and it has a width, length, and height of 6, 12, and 2.5 m, respectively, to reduce the effect of temperature differences between the upper and lower parts on the growth rate of plants in winter. This study also aimed to reduce the temperature deviation generated between the upper and lower parts of the target indoor space by optimizing the shape of the manufactured outlet of the air circulation system. A table of L9 orthogonal arrays, which is a design of experiment methodology, was used, and it presented three levels of the following design variables: blade angle, blade number, output height, and flow radius. Flow analysis was performed for the experiments on the nine models to minimize the high time and cost requirements. Based on the derived analysis results, an optimized prototype was manufactured by applying the Taguchi method, and experiments were conducted by installing 54 temperature points in an indoor space to identify the temperature difference between the upper and lower parts over time for the performance experiment. Under natural convection, the minimum temperature deviation was 2.2 °C and the temperature difference between the upper and lower parts did not decrease. For a model without an outlet shape, such as a vertical fan, the minimum temperature deviation was 0.8 °C and at least 530 s were required to reach a difference of less than 2 °C. When air was circulated in the air circulation system with the proposed outlet shape, the minimum temperature deviation was 0.6 °C and the time required to reach a difference of less than 2 °C was 440 s. Using the proposed air circulation system, cooling and heating costs are expected to be reduced in summer and winter because the arrival time and temperature difference between the upper and lower parts can be reduced using the outlet shape compared with the case without the outlet shape.

20.
Sensors (Basel) ; 23(17)2023 Sep 04.
Artículo en Inglés | MEDLINE | ID: mdl-37688110

RESUMEN

Resonance Raman spectroscopy (RRS) has been used as a reference method for measuring skin carotenoid levels (SCL), which indicate vegetable and fruit intake. However, RRS is not an easy-to-use method in SCL measurement due to its complicated implementation. In this study, a commercial spectrophotometer based on reflection spectroscopy (RS), which is relatively simple and inexpensive, was evaluated to confirm usability compared with RRS in measuring SCL. To investigate the agreement between RS and RRS, eighty participants were randomly assigned to a high-carotenoid diet group (21 mg/day of total carotenoids) or a control-carotenoid diet group (14 mg/day of total carotenoids) during a 6-week whole-diet intervention period and a 4-week tracking period. Strong correlations between the RS and RRS methods were observed at baseline (r = 0.944) and the entire period (r = 0.930). The rate of SCL increase was similar during the diet intervention; however, the initiation of the SCL decrease in RS was slower than in RRS during the tracking period. To confirm the agreement of RS and RRS from various perspectives, new visualization tools and indices were additionally applied and confirmed the similar response patterns of the two methods. The results indicate that the proposed RS method could be an alternative to RRS in SCL measurements.


Asunto(s)
Piel , Espectrometría Raman , Humanos , Carotenoides , Cognición , Verduras
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA